Loading...
HomeMy WebLinkAboutGenerator SpecsKOHLER. Models: 20RESC(L) Multi -Fuel LPG/Natural Gas 09001 Standard Features L KONLM NATIONALLY REGISTERED The Kohler Advantage • High Quality Power Kohler home generators provide advanced voltage and frequency regulation along with ultra -low levels of harmonic distortion for excellent generator power quality to protect your valuable electronics. • Extraordinary Reliability Kohler is known for extraordinary reliability and performance and backs that up with a 5-year or 2000-hour limited warranty. • Powerful Performance Exclusive Powerboost- technology provides excellent starting power. Is Corrosion -Proof Enclosure The bold new Kohler design is completely corrosion proof, even in harsh seaside environments, and is impact - resistant even at - 34' C (- 301 F). • Fast Response Kohler generators restore power to your home quickly and reliably. RDC2 Controller o One digital controller manages both the generator set and transfer switch functions (with optional Model RXT). o Designed for today's most sophisticated electronics. o Electronic speed control responds quickly to varying demand. o Digital voltage regulation protects your sensitive electronics from harmonic distortion and unstable power quality. o OnCue& Plus Generator Management System for remote monitoring is included with the generator. Kohler Command PRO Engine Features o Kohler Command PRO® OHV engine with hydraulic valve lifters for reliable performance without routine valve adjustment or lengthy break-in requirements. o Powerful, reliable air-cooled performance. c Simple field conversion between natural gas and LPG fuels while maintaining emission certification. Designed for Easy Installation o Polymer base eliminates the need for a concrete mounting pad, reducing installation time and cost. o Fuel and electrical connections through the enclosure wall eliminate the need for stub -ups through the bottom. o Load connection terminal block allows easy field wiring. a Designed for outdoor installation only. P Certifications o Meets emission regulations for U.S. Environmental Protection Agency (EPA) with both natural gas and LPG. Note: CARS does not regulate emergency standby generators with outputs less than 50 HP. o UL2200jcUL listed (60 Hz model). o CSA certification available (60 Hz model). o GOST certified (Russia). o Accepted by the Massachusetts Board of Registration of Plumbers and Gas Fitters • Approved for stationary standby applications in locations served by a reliable utility source. • 20RESCL models packaged with a Model RXT automatic transfer switch are available. See page 6 and the Model RXT ATS specification sheet. • Warranty o Standard 5-year/2000-hour limited warranty for on -grid (standby) applications in locations served by a reliable utility source. G4-246 (20RESC) 1/18d Generator Ratings 5tanaoy Ratings i-me Larcun Natural Gas LPG Breaker Alternator Voltage Phase Hz kW/kVA Amps kW/kVA Amps Amps Poles 120 * 1 60 18/18 150 20120 166 175 1 110/220 1 60 18118 81 20/20 90 100 2 1201240 * 1 60 108 75 20/20 83 100 2 100/260 1 50 15/1.5 75 16/16 8o 80 2 2F7 1151230 1 50 15/15 65 16/16 69 100 2 220 1 50 15/15 68 16116 72 80 1 230 1 50 15/15 65 15115 65 80 2 240t 1 50 13/13 54 13/13 54 80 1 120/208 * 3 60 17/21 58 17/21 58 70 3 110/220 3 60 17/21 55 17121 55 80 3 127/220 3 60 17/21 55 17/21 55 80 4 120/240 * 3 60 17/21 51 17121 51 60 3 2201380 3 60 17121 32 17121 32 40 4 2G7 277/480 * 3 60 17/21 26 17/21 26 30 3 1001200 3 50 14/17 50 15118 54 63 3 2201380* 3 50 14117 26 15118 28 32 4 230/400 3 50 14/17 25 15/18 27 32 4 2401416y 3 50 14117 24 15118 26 32 4 * UL listed, # 50 Hz single-phase models are factory -connected as 230 volts. Field -adjustable to 220 or 240 Volts by an authorized service technician. * 50 Hz 3-phase models are factory -connected as 230/400 volts. Field -adjustable to 220/380 or 240/416 Volts by an authorized service technician. Note: The line circuit breaker is automatically selected based on the generator set model and voitage configuration. RATINGS: standby ratings apply to installations served by a reliable utility source. Ail three-phase units are rated at 0.8 power factor. All single-phase units are rated at 1.0 power factor. The standby rating is applioabletovarii%ble leads with an average load factor of 80% for the duration ofthe pDwer outage. Noaverinadcapacity isspecified atthis rating. Ratings are in accordance with ISO- 304s11, BS5514, AS2789, and DIN 627t. GENERAL. GUIDELINES FOR DEBATING: ALMUDE: berate 4% per 3o5 m (1000 ft.) etevehon above 153 m (590ft.). TEMPMATURE: Derate 2%per 5.5°C (10° F) temperature increase above 18° C (60,F). Availabilitylssubieotto change without notice. The generator set manufacturer reserves the rightto changethe design or specifications without notice and without any obligation or liability whatsoever. Contact your local Kohler Co. generator distributor for availability. G4-246 (20RESC) 1J19d Alternator Specifications Alternator Specifications Alternator Features Specifications Alternator • Compliance with NEMA, IEEE, and ANSI standards for Manufacturer Kohler temperature rise. Type 2-Pole, Rotating Field . Self -ventilated and dripproof construction. Leads, quantity • Windings are vacuum -impregnated with epoxy varnish for 2F7 4 dependability and long life. 2G7 12 • Superior voltage waveform and minimum harmonic Voltage regulator Digital distortion from skewed alternator construction. Insulation: NEMA MG1-1,66 • Digital voltage regulator with �1.09'o no-load to full -load Material Class H RMS regulation. Temperature rise (60 Hz) 130*C Standby 9 Rotating -field alternator with static exciter for excellent Temperature rise (50 Hz) 150°C Standby load response. Bearing: quantity, type 1, Sealed • 'Total harmonic distortion ('i'HD) from no load to full load with Coupling Direct a linear load is less than 5%. Amortisseur windings Full Voltage regulation, no-load to full -load RMS One-step load acceptance 100% of Rating Peak motor starting kVA: (35% dip for voltages below) 240 V, 1 ph 2F7 (4 lead) 41 (60 Hz) 230 V, 1 ph 21`7 (4 lead) 28 (50 Hz) 240 or 480 V, 3 ph 2G7 (12 lead) 69 (60 Hz) 208 or 416 V, 3 ph 2G7 (12 lead) 55 (50 Hz) G4-246 (2oRESC) 1119d Application Data Engine Engine Specifications Manufacturer Kohler Engine: model, type CH10004-Cycle Cylinder arrangement V-2 Displacement, cm3 (cu. in.) 999 (61) Bore and stroke, mm (in.) 90 x 78.5 (3.54 x 3.1) Compression ratio 8.8:1 Main bearings: quantity, type 2, Parent Material Rated RPM 60 Hz 3600 50 Hz 3000 Max. engine power at rated rpm, kW (HP) LPG, 60 Hz 23,0 (30.9) LPG, 50 Hz 20.0 (26.8) Natural gas, 60 Hz 20.2 (27-1) Natural gas, 50 Hz 16.8 (22.5) Cylinder head material Aluminum Valve material Steel/Stellitelb Piston type and material Aluminum Alloy Crankshaft material Heat Treated, Ductile Iron Governor: type Electronic Frequency regulation, no load to full load Isochronous Frequency regulation, steady state --0.5% Air cleaner type dry Engine Electrical Engine Electrical System Ignition system Electronic, Capacitive Discharge Starter motor rated voltage (RC) 12 Battery (purchased separately): Ground Negative Volts (DC) 12 Battery quantity 1 Recommended cold cranking amps: (CCA) rating for -18 ° C (0° F) 500 Group size 51 Exhaust Exhaust System Exhaust temperature exiting the enclosure at rated kW, dry, °C ff) 260 (500) Lubrication Fuel Pipe Size Minimum Gas Pipe Size Recommendation, in. NPT Natural Gas LPG Pipe Length, 281,000 340,000 m (ft.) Btulhr. Btu/hr. 8 (25) 1 3/4 15 (50) 1 1 30 (100) 1 1/4 1 46 (150) 1 1/4 1 1/4 61 (200) 1 1/4 1 1/4 Lubricating System Type Full Pressure Oil capacity (with filter), L (qt.) 1.9 (2.0) Gil filter: quantity, type 1, Cartridge Oil cooler Integral Fuel Requirements Fuel System Fuel types Natural Gas or LPG Fuel supply inlet 1/2 NPT Fuel supply pressure, kPa (in. H20): Natural gas 0.9-2.7 (3.5-11) LP 1.7-2.7 (7-11) Fuel Composition Limits Nat. Gas LPG Methane, % by volume (minimum) min. - Ethane, % by volume (maximum) 4.0 max. - Propane, % by volume 1.0 max. 85 min. Propene, % by volume (maximum) 0.1 max. 5.0 max. C4 and higher, % by volume 0.3 Max. 2.5 max. Sulfur, ppm mass (maximum) 25 max. Lower heating value, MJ/m3 (St oti, (minimum) 33.2 (890) 84.2 (2260) * Contact your local distributor for suitability and rating derates based on fuel compositions outside these limits. Operation Requirements Fuel Consumption Fuel Fuel Consumption, m3/hr. (cfh) Model Type % Load 60 Hz 50 Hz 100 8.0 (281) 6.4 (226) 75 6.9 (243) 5.4 (189) Natural 60 4.6 (161) 3.9 (139) Gas 25 3.6 (127) 2.9 (103) Exercise 2.0 (71) 2.0 (71) 20RESC 100 3.9 (136) 2.9 (102) 75 3.1 (1o9) 2A (86) LPG 50 2.3 (82) 1.8 (63) 25 1.7 (59) 1.3 (47) Exercise 1.0 (35) 1.0 (36) Nominal fuel rating: Natural gas: 37 MJ/m3 (1000 Btu/ft.3) LPG: 93 MJ/m3 (2500 Btu/ft.3) LPG conversion factors: 8.58 ft.3 = 1 lb. 0.535 m3 = i kg 36,39 ft.3 = 1 gal. G4-246 (20RE80) 1/19d RDC2 Controller • Front -access mini USB connector for SiteTech— or US F.q: zao v Freq: 6Q.0 Hx The RDC2 controller provides integrated control for the generator set, Kohler® Model RXT transfer switch, programmable interface module (PIM), and load shed kit. The RDC2 controller's 2-line LCD screen displays status messages and system settings that are clear and easy to read, even in direct sunlight or low light. RDC2 Controller Features • Membrane keypad: o OFF, AUTO, and RUN pushbuttons o Select and arrow buttons for access to system configuration and adjustment menus • LED indicators for OFF, AUTO, and RUN modes • LED indicators for utility power and generator set source availability and ATS position (Model RXT transfer switch required) • LCD display: o Two lines x 16 characters per line a Backlit display with adjustable contrast for excellent visibility in all lighting conditions • Scrolling system status display: o Generator set status o Voltage and frequency o Engine temperature o Oil pressure o Battery voltage o Engine runtime hours • Gate and time displays • Smart engine cooldown senses engine temperature • Digital isochronous governor to maintain steady-state speed at all loads • Digital voltage regulation: ± 1.0% RMS no-load to full -load • Automatic start with programmed cranking cycle • Programmable exerciser can be set to start automatically on any future day and time, and run every week or every two weeks • Exercise modes: o Unloaded weekly exercise with complete system diagnostics o Unloaded full -speed exercise c Loaded full -speed exercise (Model RXT ATS required) Utility connection . Integral Ethernet connector for Kohler® OnCueO Plus • Built-in 2.5 amp battery charger • Remote two -wire start/stop capability for optional connection of a Model RDT transfer switch • Diagnostic messages: o Displays diagnostic messages for the engine, generator, Model RXT transfer switch, programmable interface module (PIM), and load shed kit c Over 70 diagnostic messages can be displayed • Maintenance reminders • System settings: o System voltage, frequency, and phase o Voltage adjustment o Measurement system, English or metric • ATS status (Model RXT ATS required): o Source availability o ATS position (normal/utility or emergency/generator) o Source voltage and frequency • ATS control (Model RXT ATS required): o Source voltage and frequency settings o Engine start time delay o Transfer time delays o Voltage calibration o Fixed pickup and dropout settings • Programmable Interface Module (PIM) status displays: o input status (activernactive) o Output status (active/inactive) • goad control menus: o Load status o Test function Generator Set Sound Data Model 20RESC 8 point logarithmic average sound levels are 64 dB(A) during weekly engine exercise and 69 dB(A) during full -speed generator diagnostics and normal operation. For comparison to competitor ratings, the lowest point sound levels are 62 dB(A) and 67 dB(A) respectively.* All sound levels are measured at 7 meters with no load. * Lowest of 8 points measured around the generator_ Sound levels at other points around generator may vary depending on installation parameters. G4-246 (20RE5C) 1/190 KOHL KOHLER, Phone 9 C45 Kohler, Wisconsin 9-1 USA Phone 920-457-4441, Fax 920-459-1646 For the nearest sates and service outlet in the US and Canada, phone 1-800-544-2444 KOHLERPower.com Generator Set Standard Features • Battery cables • EPA certified fuel system • Corrosion -proof polymer sound enclosure • Critical silencer • Field -connection terminal block • Fuel solenoid valve and secondary regulator • Line circuit breaker • Multi -fuel system, LPG/natural gas, fiieid-convertible • nil drain extension with shutoff valve • OnCue® Plus Generator Management System • Premium 5-year limited warranty • RDC2 generator set/ATS controller • Rodent -resistant construction • Sound -deadening, flame-retardant foam per UL94, class HF-1 Available Options Approvals and Listings ❑ CSA approval Communication Accessories ❑ OnCue® Plus Wireless Generator Management System Concrete Mounting Pads ❑ Concrete mounting pad, 3 in. thick ❑ Concrete mounting pad, 4 in. thick (recommended for storm -prone areas) Electrical Accessories ❑ Battery ❑ Battery heater, 120VAC ❑ Battery heater, 240VAC ❑ Cold weather package, 120VAC ❑ Cold weather package, 240VAC ❑ Emergency stop kit a PowerSyn& Automatic Paralleling Module (APM) (single phase only) ❑ Programmable interface module (PIM) (provides 2 digital inputs and 6 relay outputs) Fuel System Accessories ❑ Flexible fuel fine (included on Quick -ship [QS] models) ❑ Carburetor heater, 120 VAC ❑ Carburetor heater, 240 VAC Carburetor heater is recommended for reliable starting at temperatures below 0°C (32'F ) ❑ Fuel regulator heater pad 120VAC ❑ Fuel regulator heater pad 240VAC Fuel regulator heater is recommended for reliable starting at temperatures below -IVC (0°F). Literature ❑ General maintenance literature kit ❑ Overhaul literature kit ❑ Production literature kit Available Options, Continued Maintenance ❑ Maintenance kit (includes air filter, oil, oil filter, and spark plugs) Warranty ❑ Optional Extended 5-Year/2000 Hour Comprehensive Limited Warranty Automatic Transfer Switches and Accessories ❑ Model RDT ATS ❑ Model RXT ATS ❑ Model RXT ATS with combined interface/load management board ❑ Load shed kit for RXT or RDT ❑ Power relay modules (use up to 4 relay modules for each load management device) ❑ Other Kohler® ATS 20RESCL Model Packages ❑ 20RESCL with 100 amp RXT with 16-space load center and NEMA 1 steel enclosure for indoor installation ❑ 20RESCL with 200 amp service entrance -rated Model RXT with combined interfacelload management board and corrosion -resistant NEMA 3R aluminum enclosure Generator Set Dimensions and Weights Overall Size, L x W x H: 1216 x 665 x 733 mm (48 x 26.2 x 29 in.) Shipping Weight: Shipping Weights: 20RESC Generator Set: 20RESCL with 100 A RXT ATS w/LC 20RESCL with 200 A RXT SE ATS: 243 kg (535 lb,) 243 kg (535 lb.) 268 kg (591 lbs.) 263 kg (580 lb,) i�-rlrw (rim• ls'l�til 'l�,xaAll�slttAllt<� NOTE: Dimensions are provided for reference only and should not be used for planning insWinfion, Contact your local distributor for more detaited information. DISTRIBUTED BY. (� 2015, 2016, 2047, 2019 by Kohler Co. Ail rigitts reserved. G4-246 (20RESC) 1119d