Loading...
HomeMy WebLinkAboutCertification for Design Load Compliance}.. Planning & Development Services Department o Building & Code Regulations Division 2300 Virginia Avenue, Fort Pierce, FL 34982 — (772) 462-1553 Certification for Design Load Compliance Project Name: 903MA4-0M SI (IhlJ Project Address: 511.6 w 7d-n!6 Permit #: Occupancy Type: 1E. Construction Type: INSTRUCTIONS FOR USE: • This certification must be completed, signed, and sealed by the design professional of record. • . Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following: o New Residences (single or multi -family) o Residential Addition o Any accessory structure requiring a building permit o Any non-residential structure. * Note: Form not required for interior renovations provided that no exterior structural elements are affected and certain minor building permits at the discretion of the local building official. Contact the # above for questions. DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply) 1. DESIGN CODE: Florida 81A1LQ)14 Cs Code Fifth Edition with 20,--L+—Supplements using ASCE 7-10 2. Structure Designed as (check one): Enclosed Partially Enclosed Open 3. Risk Category: _I _�_: II 111 IV Exposure Category: B C X_D 4. Design Wind Velocity d 70 mph ASD LRFD End Zone Width: _!k_ft 5. Mean Roof Height 4%. $4 ft Roof Pitch: 5 :12 Parapet: — ft 6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings): Zone 1: 4-0,2 -S 1 Zone 2:$3Z — 9 Zone 3: 1Zone 4:+56 —6®Zone 5Garage: a' T "57 7. Design Loads: Floor: 40_PSF Roof/Dead: ?_o PSF Roof/Live: ZO Balcony: 100 PSF Dock: _PSF Deck: PSF Stairs: fo0 PSF Fence: A PSF Railings: PSF 8. Were Shear Walls Considered For Structure? is Yes Not Applicable Explain Why Not: 9. Is A Continuous Load Path Provided? X Yes Not Applicable Explain Why Not: 10. Design Soil Bearing Pressure: 2 5 00 PSF Soil Test Reports Submitted? X Yes DESIGN PROFESSIONAL CERTIFICATION STATEMENT: I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie County. I also certify that structural elements depicted on these plans provide adequate resistance to the design forces specified: fr"" D 2• PM 07-0,_X 0, Alt C 5 4-o Print Name Cert # & Co. Cert Auth. Signature, Date, and Seat Company Name & Address Revised 07/25/2014