Loading...
HomeMy WebLinkAboutCarport plans, engineeringCONTRACTOR East Coast Alum' n Products, Inc. DESIGN CRITERIA: U^ Applicable Codes. Regulations, and Standards 1. The 5th Edition (2014) Florida Building Code, specifically Chapter 16 Structural Design, Chapter 20 Aluminum, and Chapter 23 Wood. 2. AA ASM 35 and Specifications for Aluminum Structures, Part 1-A of the Aluminum Design Manual prepared by The Aluminum Association, Inc. Washington, D.C., 2005 Edition 3. ASCE 7-10. Wind Loads 1. Building Occupancy Category, Paragraph 1604.5 and Table 1604.5: Risk Category 1. 2. Basic Wind Speed, Table 1609C, State of Florida Debris Region & Basic Wind Speed, Paragraph 1609.3.1 and Table 1609.3.1 Equivalent Basic Wind Speed: Vtn.T=150 MPH VasD=116 MPH 3. Exposure Category, Paragraph 1609.4.3: Exposure C 4. Building Category for Aluminum Structures, Paragraph 2002.6: Building Category 1- Carport: Non -Habitable, Unconditioned Scope of Work: Roof Replacement Only. Does not include analysis of existing structure Roof Type L Roof Type: MONOSLOPE 2. Roof Material: 3" x 48" x 0.624" composite panel Elite 2000, 1.0 density foam, Florida Product Approval Number FL 7561-R3. Foundation Design Existing concrete slab. No additional concrete footing or slab is required to resist the loads imposed upon the existing slab by the proposed construction if the existing slab is a minimum of 4" thick and in sound condition, free from structural cracking, spalling, or other deterioration, Specifications The following specifications are applicable to this project: 1. All work shall be in accordance with the 5th Edition (2014) Florida Building Code, and any other applicable local codes and regulations. 2. Aluminum extrusions shall be 6005 T5 Alloy. Due to quality control issues, no manufacturer substitution is acceptable without the specific written, signed and sealed authorization of Suncoast Aluminum Engineering, LLC. 3. Screen Material: Design based on 18114 or 2020 Better View. Any other material must be approved. 4. Fasteners are required to be corrosion resistant, minimum SAE Grade 2 or better zinc plated to ASTM B633, or coated stainless steel series "300", or uncoated stainless steel series "400". 5. All Self Mating Beam Sections are to be stitched with either 914 screws 6" from ends and 24" center to center or 412 screws 6" from ends and 12" center to center. 6. Whine concrete specifications are required, whether in the screen enclosure scope or not, by one or more regulatory agency, the following specifications are applicable: a. Concrete shall conform to ASTM C94 for the following components. i Portland Cement Type 1,- ASTM C 150 n. Aggregates - Large Aggregate 3/4" max - ASTM C 33 iii. Air entraining +/-1%-ASTM C 260 iv. Wafer reducing agent - ASTM C 494 v. Clean Potable water vi. Other admixtures not permitted b. Metal accessories shall conform to: i. Reinforcing Bars - ASTM A615, grade 60 ii. Welded wire fabric - ASTM A185 c. Concrete slump at discharge chute not less than 3"or more than 5". Water added after hatching is not permitted. d. Prepare and place concrete per American Concrete Institute Manual of Standard Practice, Parts 1, 2, and 3 including hot weather recommendations. e. Moist cue or polyethylene curing permitted. f. Prior to placing concrete, treat the entire subsurface area for termites in compliance with the FBC. g. Concrete shall be placed over a polyethylene vapor barrier. h. All aluminum components embedded within concrete shall be coated with a bituminous paint or epoxy. 7. All flashing and weatherproofing shall be provided by the contractor. 8. Door location shall be determined by contractor in the field. 9. Use of these plans acknowledges and accepts a limit of liability not to exceed design and engineering fee. EXISTING COMPOSITE PANEL EXISTING CAR PORT EXISTING ME 3"X48"XO.024" 1.0 DENSITY FOAM COMPOSITE PANEL EXISTING EDGE �J 9'-O"-4 1'-0" COMPOSITE PANEL i EXISTING EXISTING UU0.060 j 3X3XO.060 M POST POST I IV i Oj i t T 9-3 f 7"HESE PLANS AND ALL PROPOSED WORK ARE SUBJECT TO ANY CORRECTIONS REQUIRED BY FIELD INSPECTORS THAT MAYBE NECESSARY In 00ATLYWITHALCAPP�. CA®LECODES not-oi6L ST. LI1C COUN7V IRUIL)I NG DMSION REVIEWED FOR CONftj&NCE REVIEWED DATE PLANS PE IT MUST BE KEPT ON JOB OR NO INSPECTION WILL BE 1R4 WE, O ❑ K ui 0 w w n a Cr LL 03 Z 0m Qa y �Z Z Z Wz �Li Z W V O U W tt; d F LL Z U 0 J W J r N 1- Q Z og QW IS Zaryn Z C7 Z o3�CG 7 "' � VI LLJ AG 11/04/16 SHEET NO: A-1 I ALUMINUM MEMBERS DIMEN NS HOLLOW SECTIONS 2x2: 2"x2"xO.046" 2x3: 2"x3"x0.050" 2 x4: 2"x4"x 0.050" 2 x 5: 2" x 5" x.0.050" OPEN RACK SECTIONS I x2: I"x2"X 0.040" I x3: 1"x3"x0.045" SNAP SECTIONS 2 x 2 Snap: 2" x 2" x 0.045" 2 x 3 Snap: 2" x 3" x 0.050" 2 x 4 Snap: 2" x 4" x 0.045" SELF MATING (SMB) 2 x 4 SMB: 2" x 4" x 0.044" x 0. 100" 2 x 5 SMB: 2" x 5" x 0.050" x 0. 100" 2 x 6 SMB: 2" x 6" x 0.050" x 0. 120" 2 x 7 SMB: 2" x 7" x 0.057" x 0. 120" 2 x 8 SMB: 2" x S" x 0.072" x 0. 124" 2 x 9 SMB: 2" x 9" x 0.072" x 0.124" 2 x 10 SMB: 2" x 10" x 0.092" x 0.398" MINIMUM FASTENER EDGE DISTANCE: 1/2" MINIMUM FASTENER SPACING: 3/4" CONCRETE SCREW ANCHOR: SIMPSON TITEN HD OR EQUIVALENT SHEET METAL SCREWS (SMS): ITW / BUILDEX OR EQUIVALENT E-GUTTER W/' TOP & BOT. (3 (4) #14 x 4 718" SMS W/ NEOPRENE FACED WASHER EA. PANEL COMPOSITE PANEL x 5" SMB EXISTING 3"x3"x O.OStl' POST S COMPOSITE ROOF TO POST CONNECTION A-2 SCALE: NTS I 11 IIIIf1/// CON �. l l O p'• , = Nk v0: Z FLASHING 3" COMPOSITE //// �' •••••••••O`�\� ROOF PANEL \ r' PROFE SIONAL SEAL A (4)#14x47/S"SMS W/ k � � NEOPRENEFACED E%ISTNG I Ld WASHER EA. PANEL t BUILDING/, 0 ui C W r EXi LL Q Z 2"xS'SM8 (= 5"SMB O C w Q w EXISTINGI I rx I W O w d i 3"x3"x0o6al.08tl' I € W i m vl W POST Q I I __ V wu Ou z I.— w �LL F LL EXISTING F S-1 COMP. ROOF TO POST an, 4TH WALL DETAIL A 2 SCALE NTS #10 x 3/4" SMS H-CHANNEL S-2 COMPOSITE ROOF TO EXISTING ROOF A-2 A 2 D G J J N J Z o Q Laim < O LLI W i V Z arN Z (D 3 -- a Ln W - w 5 9 N W L F p U a0w U � W U N U W O�ma� I-r DATE DRAWN 11 /04/16 REVISION SHEET NO: A-2