Loading...
HomeMy WebLinkAboutEnergy Calculation Form & Manual J's FORM R405-2014 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: CAPELLI RESIDENCE Builder Name: Street: 805 NORTH LAKE DRIVE Permit Office: City,State,Zip: FORT PIERCE,FL, Permit Number. Owner: Jurisdiction: Design Location: FL,Fort Pierce County:: ST.LUCIE COUNTY(Florida Climate Zone 2) 1. New construction or existing Addition 9. Wall Types(756.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Ext Insul,Exterior R=4.1 756.00 ft2 b.N/A R= ft2 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms(Bedrms In Addition) 1(0) d.N/A R= ft2 5. Is this a worst case? No 10.Ceiling Types (558.0 sqft.) Insulation Area a.Under Attic(Vented) R=30.0 558.00 ft2 6. Conditioned floor area above grade(ft2) 558 b.N/A R= ft2 Conditioned floor area below grade(ft2) 0 c.N/A R= ft2 11.Ducts R ft2 7. Windows(71.7 sqft.) Description Area a. U-Factor. Dbl,U=0.65 71.67 ft2 _ SHGC: SHGC=0.25 b. U-Factor: N/A ft2 12.Cooling systems kBtu/hr Efficiency SHGC: a.Central Unit 12.0 SEER:24.20 c. U-Factor: N/A ft2 SHGC: 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a.Electric Heat Pump 12.0 HSPF:10.55 SHGC: .Area Weighted Average Overhang Depth: 2.000 ft. Area Weighted Average SHGC: 0.250 14.Hot water systems- 8. Floor Types (558.0 sqft.) Insulation Area a.Electric Cap:40 gallons EF:0.950 a.Slab-On-Grade Edge Insulation R=0.0 558.00 ft2 b. Conservation features b.N/A R= ft2 None c.N/A R= ft2 15.Credits CF,Pstat Glass/Floor Area: 0.128 Total Proposed Modified Loads: 13.37 PASS Total Baseline Loads: 23.86 I hereby certify that the plans and specifications covered by Review of the plans and FTHE S'r this calculation are in compliance with the Florida Energy specifications covered by this Code. calculation indicates compliance with the Florida Energy Code. PREPAR D B : Before construction is completed r� DATE: this building will be inspected for - �7, a ' compliance with Section 553.908 * ° I hereby certify that this building,as designed, is in compliance Florida Statutes. with the Florida Energy Code. E' / Cobh OWNER/AGENT: BUILDING OFFICIAL: DATE: - DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.2.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage test report in accordance with R402.4.1.2. 1/23/201711:59 AM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 4 FORM R405-2014 PROJECT Title: CAPELLI RESIDENCE Bedrooms: 1 Address Type: Street Address Building Type: User Conditioned Area: 558 Lot# Owner: Total Stories: 1 Block/SubDivision: #of Units: 1 Worst Case: No PlatBook: Builder Name: Rotate Angle: 0 Street: 805 NORTH LAKE DRI Permit Office: Cross Ventilation: No County: ST.LUCIE COUNTY Jurisdiction: Whole House Fan: No City,State,Zip: FORT PIERCE, Family Type: Single-family FL, New/Existing: Addition Comment: CLIMATE IECC Design Temp Int Design Temp Heating Design Daily Temp \/ Design Location TMY Site Zone 97.5% 2.5% Winter Summer Degree Days Moisture Range FL,Fort Pierce FL VERO_BEACH_MUNI 2 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 558 5022 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 LIVING AREA 418 3762 Yes 0 1 Yes Yes Yes 2 BEDROOM 140 1260 No 2 1 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood. Carpet 1 Slab-On-Grade Edge Insulatio LIVING AREA 64 ft 0 418 ft2 0 1 0 2 Slab-On-Grade Edge Insulatio BEDROOM 20 ft 0 140 ft2 0 1 0 ROOF Roof Gable Roof Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Gable or Shed Composition shingles 588 ft2 92 ft2 Medium 0.6 No 0.9 No 0 18.4 ATTIC V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC 1 Full attic Vented 150 558 ft2 N N 1/23/2017 11:59 AM EnergyGaugeO USA-FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 4 FORM R405-2014 CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic(Vented) LIVING AREA 30 Blown 418 ft2 0.1 Wood 2 Under Attic(Vented) BEDROOM 30 Blown 140 ft2 0.1 Wood WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below t TO WaU-Type Space R-Vable Ft In Ft In Area R_Va o 1 N Exterior Concrete Block-Ext InstiVING ARE 4.1 6 0 9 0 54.0 ft2 0 0 0.6 0 2 E Exterior Concrete Block-Ext lnsUOVING ARE 4.1 25 0 9 0 225.0 ft2 0 0.25 0.6 0 3 S Exterior Concrete Block-Ext InsUIVING ARE 4.1 23 0 9 0 207.0 ft2 0 0.25 0.6 0 4 W Exterior Concrete Block-Ext Ins1iVING ARE 4.1 10 0 9 0 90.0 ft2 0 0.25 0.6 0 5 N Exterior Concrete Block-Ext InsfilEDROOM 4.1 6 0 9 0 54.0 ftz 0 0.25 0.6 0 6 W Exterior Concrete Block-Ext InsiffiEDROOM 4.1 14 0 9 0 126.0 ft2 0 0.25 0.6 0 DOORS # Omt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 S Insulated LIVING ARE None .39 3 6 8 20 ft2 WINDOWS Orientation shown is the entered,Proposed orientation. Wall Overhang V # Omt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening 1 E 2 Metal Low-E Double Yes 0.65 0.25 18.0 ft2 2 ft 0 in 1 ft 4 in None None 2 S 3 Metal Low-E Double Yes 0.65 0.25 17.7 ft2 2 ft 0 in 1 ft 4 in None None 3 W 4 Metal Low-E Double Yes 0.65 0.25 18.0 ft2 2 ft 0 in 1 ft 4 in None None 4 W 6 Metal Low-E Double Yes 0.65 0.25 18.0 ft2 2 ft 0 in 1 ft 4 in None None INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .0004 585.9 32.17 60.49 .2922 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump None HSPF:10.55 12 kBtu/hr 1 Ductless COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit Split SEER:24.2 12 kBtu/hr 360 cfm 0.8 1 Ductless 1/23/2017 11:59 AM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 4 FORM R405-2014 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None LIVING AREA 0.95 40 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model# Collector Model# Area Volume FEF None None ft2 TEMPERATURES Programable Thermostat:Y Ceiling Fans: [X rl Cooling eat ng Nov H Dec Jan Feb f X�Mar Apr May r]AprJuay n rj Jul E Aug Sep La Occtt X Nov DecVenting Jan Feb [X Mar Jun Jul Aug Sep lxl Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 1/23/201711:59 AM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 4 FORM R405-2014 TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: CAPELLI RESIDENCE Builder Name: Street: 805 NORTH LAKE DRIVE Permit Office: City,State,Zip: FORT PIERCE,FL, Permit Number: Owner: Jurisdiction: Design Location: FL,Fort Pierce COMPONENT CRITERIA CHECK Air barrier and thermal barrier A continuous air barrier shall be installed in the building envelope. Exterior thermal envelope contains a continuous barrier. Breaks or joints in the air barrier shall be sealed. Air-permeable insulation shall not be used as a sealing material. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the insulation and any gaps in the air barrier shall be sealed. Access openings,drop down stairs or knee wall,doors to unconditioned attic spaces shall be sealed. Corners and headers shall be insulated and the junction of the foundation Walls and sill plate shall be sealed. The junction of the top plate and the top or exterior walls shall be sealed. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Knee walls shall be sealed. Windows, skylights and doors The space between window/door jambs and framing and skylights and framing shall be sealed. Rim joists Rim joists are insulated and include an air barrier. Floors (including above-garage Insulation shall be installed to maintain permanent contact with underside and cantilevered floors) of subfloor decking. The air barrier shall be installed at any exposed edge of insulation. Crawl space walls Where provided in lieu of floor insulation, insulation-shall be permanently attached to the crawlspace walls. Exposed earth in unvented crawl spaces shall be covered with a Class I vapor retarder with overlapping joints taped. Shafts, penetrations Duct shafts, utility penetrations,and flue shaft openings to exterior or unconditioned space shall be sealed. Narrow Cavities Batts in narrow cavities shall be cut to fit,or narrow cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal envelope shall be air tight, IC rated,and sealed to the drywall. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls,or insulation that on installation readily conforms to available space shall extend behind piping and wiring. Shower/tub on exterior wall Exterior walls adjacent to showers and tubs shall be insulated and the air barrier installed separating them from the showers and tubs. Electrical/phone box on The air barrier shall be installed behind electrical or communication boxes or air sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub-floor or drywall. Fireplace An air barrier shall be installed on fireplace walls. Fireplaces shall have gasketed doors 1/23/201711:59 AM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 1 / FORM R405-2014 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 56 The lower the EnergyPerformance Index, the more efficient the home. 805 NORTH LAKE DRIVE, FORT PIERCE, FL, 1. New construction or existing Addition 9. Wall Types Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Ext Insul,Exterior R=4.1 756.00 ftz b.N/A R= ft 3. Number of units,if multiple family 1 c.N/A R= ftz 4. Number of Bedrooms 1(0) d.N/A R= ftz 5. Is this a worst case? No 10.Ceiling Types Insulation Area a.Under Attic(Vented) R=30.0 558.00 ftz 6. Conditioned floor area(ftp 558 b.N/A R= ftz 7. Windows— Description Area c.NIA R= ft= a. U-Factor: Dbl,U=0.65 71.67 ftz 11.Ducts R ftz SHGC: SHGC=0.25 b. U-Factor: N/A ftz SHGC: 12.Cooling systems kBtu/hr Efficiency c. U-Factor: WA ftz a.Central Unit 12.0 SEER:24.20 SHGC: .d. U-Factor: N/A ftz 13.Heating systems kBtu/hr Efficiency SHGC: a.Electric Heat Pump 12.0 HSPF:10.55 Area Weighted Average Overhang Depth: 2.000 ft. Area Weighted Average SHGC: 0.250 8. Floor Types Insulation Area 14.Hot water systems- a.Slab-On-Grade Edge Insulation R=0.0 558.00 ftz a.Electric Cap:40 gallons EF:0.95 b.N/A R= ftz c.N/A R= ftz b. Conservation features None 15.Credits CF,Pstat I certify that this home has complied with the Florida Energy Efficiency Code for Building �zBE ST,gT Construction through the above energy saving features which will be installed (or exceeded) .y0 _ Fo in this home before final i Oction. Otherwise, a new EPL Display Card will be completed ", °''�1• 1 Z based on installed C o' pl' n features. �z,�`=�°, o Builder Signature: Date: C Address of New Home: �Q$��LG�� /�G� City/(L Zip: �'gy' �,C oD WE IT 3 V *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage(EEM)incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at(321) 638-1492 or see.the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 1/23/2017 11:59 AM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Compliant Software Page 1 of 1 9 Project Summa Job: wri htsoft Entre House Date: Jan 23,2017 By: QUICK CALCS, INC. 317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone:772-466-6799 Fax 772-466-6796 Email:QUICKCALCS@AOL.COM Proiect Information For: CAPELLI GARAGE CONVERSION 805 NORTH LAKE DRIVE, FORT PIERCE, FL Notes: Design Information Weather: Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db 70 OF Inside db 75 OF Design TD 28 OF Design TD 15 OF Daily range L Relative humidity 50 % Moisture difference 61 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 8828 Btuh Structure 6346 Btuh Ducts 1629 Btuh Ducts 2491 Btuh Central vent.(23 cfm) 714 Btuh Central vent.(23 cfm) 383 Btuh Outside air Outside air Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 11171 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Infiltration Equipment sensible load 8758 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 1119 Btuh Ducts 668 Btuh Central vent(23 cfm) 970 Btuh Heating Cooling Outside air Area(ftZ 558 558 Equipment latent load 2756 Btuh Volume(ft ) 5022 5022 Air changes/hour 0.61 0.32 Equipment total load 11515 Btuh Equiv.AVF (cfm) 51 27 Req. total capacity at 0.70 SHR 1.0 ton Heating Equipment Summary Cooling Equipment Summary Make DIAKIN Make DIAKIN Mode del RXG12HVJU Cond RXG12HVJU AHRI ref 3208522 Coil FTXG12HVJU AHRI ref 3208522 Efficiency 10.55 HSPF Efficiency 14.0 EER, 24.2 SEER Heating input Sensible cooling 8400 Btuh Heating output 11500 Btuh @ 47°F Latent cooling 3600 Btuh Temperature rise 27 OF Total cooling 12000 Btuh Actual air flow 383 cfm Actual air flow 383 cfm Air flow factor 0.037 cfm/Btuh Air flow factor 0.043 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.77 Capacity balance point=40 OF Backup: Input=4 kW, Output= 13571 Btuh, 100 AFUE Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 4 wrightsot<t' Ri ht-Suite®Universal 2017 17.0.14 RSU08101 2017-Jan-23 11:59:44 .CCK 9 Page 1 ...DocumentslWrightsoft HVAC\CAPELLI RESIDENCE.rup Calc=MJ8 Front Door faces: N +�-wrightsort° Right-M Worksheet Job: Entire House Date: Jan 23,2017 QUICK CALCS, INC. By. 317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone:772-466-6799 Fax 772-466.6796 Email:QUICKCALCS@AOL.COM 1 Room name Entire House LIVING AREA 2 Exposed wall 84.0 ft 64.0 ft 3 Room height 9.0 ft d 9.0 ft heat/cool 4 Room dimensions 1.0 x 418.0 ft 5 Room area 558.0 ftz 418.0 ftz Ty Construction U-value Or HTM Area (ftj Load Area (ftp Load number (Btuh/ftk-°F) (Btuh/ftj or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Grass N/P/S Heat Cool Gross N/P/S Heat Cool 6 W 13A-4ocs 0.143 n 4.00 2.55 108 108 432 275 54 54 216 137 W 13A-4ocs 0.143 a 4.00 2.55 225 207 829 527 225 207 829 527 L—G 4A5-2om 0.770 a 21.56 47.10 18 0 388 848 18 0 388 848 IW 13A-4ocs 0.143 s 4.00 2.55 207 168 674 428 207 168 674 428 11 I--c� 4A5-2om 0.770 s 21.56 19.31 18 18 381 341 18 18 381 341 LZ 11DO 0.390 s 10.92 11.31 21 21 229 238 21 21 229 238 UV 13A-4ocs 0.143 w 4.00 2.55 216 180 721 458 90 72 288 183 I--G 4A5-2om _ 0.770 w 21.56 47.10 36 0 776 1696 18 0 388 848 C 16B-30ad 0.032 - 0.90 1.68 558 558 500 937 418 418 375 702 F 22A4pl 0.989 - 27.69 0.00 558 84 2326 0 418 64 1772 0 6 c)AED excursion 156 -145 Envelope loss/gain 7257 5904 5541 4107 12 a) Infiltration 1571 442 1197 336 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 8828 6346 6738 4444 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 8828 6346 6738 4444 15 Duct loads 18% 39% 1629 2491 18% 39% 1243 1744 Total room load 10456 1 88377981 6188 Air required(cfm) 383 383 292 268 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrightsoft` 2017-Jan-2311:59:44 Right-Suite®Universal 2017 17.0.14 RSU08101 Page 1 Documents\Wrightsoft HVAC%CAPELLI RESIDEN CE.rup Calc=MJ8 Front Door faces: N e - wrightsoft Right-M Worksheet Job: Entire House Date: Jan 23,2017 By: QUICK CALCS, INC. 317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone:772-466-6799 Fax 772-466-6796 Email:QUICKCALCS@,AOL.COM 1 Room name BEDROOM 2 Exposed wall 20.0 ft 3 Room height 9.0 ft heattcool 4Room dimensions 1.0 x 140.0 ft 5 Room area 140.0 ft2 Ty Construction U-value Or HTM Area (ftj Load Area Load number (Btuh/ftk*F) (Btuh/ftj or perimeter (ft) (Btuh) or perimeter Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 W 13A4ocs. 0.143 n 4.00 2.55 54 54 216 137 lq✓ 13A-0ocs 0.143 a 4.00 2.55 0 0 0 0 �G 4A5-2om 0.770 a 21.56 47.10 0 0 0 0 W 13A-4ocs 0.143 s 4.00 2.55 -0 0 0 0 11LZ4A5-20m 0.770 s 21.56 19.31 0 0 0 0 11DO 0.390 s 10.92 _ 11.31 0 0 0 0 13AAocs 0.143 w 4.00 2.55 126 108 432 275 4A5-2om 0.770 w 21.56 47.10 18 0 388 848. C 16B-30ad 0.032- - 0.90 1.68 140 140 125 235 F- - 22A-tpl 0.989 - 27.69 0.00 140 20 554 0 6 0)AED excursion 302 Envelope loss/gain 1716 1797 12 a) Infiltration 374 105 b) Room ventilation 0 0 13 Internal gains: Occupants @ 230 0 0 Appliances/other 0 Subtotal(lines 6 to 13) 2090 1902 Less external load 0 0 Less transfer 0 0 Redistribution 0 0 14 Subtotal 2090 1902 15 Duct loads 18% 39% 386 747 Total room load T2476 2649 Air required(cfm) 91 115 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. .ACP.Ad- wrightsoft, 2017-Jan-23 11:59:44 Right-Sulte®Universal 2017 17.0.14 RSU08101 Page 2 ...Documents\Wdghtsoft HUACICAPELLI RESIDENCE.rup Calc=MJS Front Door faces: N