HomeMy WebLinkAboutEngineering PlansPlanning & Development Services Department D Building & Code Regulations Division 2300 Virginia Avenue, Fort Pierce, FL 34982 - (772) 462-1553 Certification for Design Load Compliance Project Name: CAPELLI GARAGE CGVERSION Project Address: 805 NORTH LAKE DR - Permit#: Occupancy Type: R Construction Type: V INSTRUCTIONS FOR USE: • This certification must be completed, signed, and sealed by the design professional of record. • Submit (2) copies for residential; (3) copies for commercial with all permit applications Involving the following: a New Residences (single or multi -family) o Residential Addition o Any accessory structure requiring a building permit o Any non-residential structure. 'r Note: Form not required for interior renovations provided that no exterior structural elements are affected and certain minor building permits at the discretion of the local building official. Contact the # above for questions. DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply) T. DESIGN CODE: Florida Building Code 2014 Edition with 2014 Supplements using ASCE 7-10 2. Structure Designed as (check one): X Enclosed -Partially Enclosed _Open 3. Risk Category: _ I XII_ III_ IV Exposure. Category: _B X CD 4. Design Wind Velocity 160 mph . 124 ASD N/A LRFD End Zone Width: 5 ft S. Mean Roof Height: 15 ft Roof Pitch: N/A :12 Parapet: N/A ft 6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings): 19.3 19.3 19.3 33.6 33.6 N/A Zone 1i -30.7 Zone 2: -53.5 Zone 3: _79.1 Zone 4: -36.4 Zone 5: -44.9 Garage: � N/A 7. Design 'Loads: 40 PSF Roof/Dead: 5 PSF Roof/Live: 20 Balcony: • N/A PSF Dock: N/A PSF Deck: N/A PSF Stairs: N/A . PSF Fence: N/A PSF Railings: N/A PLF / CONCENTRATED S. Were Shear Walls Considered Far Structure? R Yes _Not Applicable Explain Why Not: 9. Is A Continuous Load Path Provided? %Yes Not Applicable Explain Why Not: 10. Design Soil Bearing Pressure: 2500 PSF Soil Test Reports Submitted? _„-Yes DESIGN PROFESSIONAL CERTIFICATION STATEMENT: I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie County. I also certify that structural elements depicted on these plans provide adequate resistance to the design forces specified: Paul Welch P.E. 29945 / 5115 Print Name Cert # & Co. Cert Auth. Paul Welch Inc. ON PLAN 11/30/2016 Signature, Date, and Seal 1984 S.W. Biltmore St, Suite #114 Port St. Lucie, FL Company Name & Address ACCOV Farm 1102D-12 Revised 3/15/12 (5) City of Port St. Lucie Building Department Product Approval Submittal Affidavit Permit # Building Address: 805 NORTH LAKE DR Contractor: Opening Schedule : Swing doors, Overhead Doors, Sliding Doors, Fixed Glass, Windows &Skylights Opening ID FL If or NOA # Product Model # Manufacturer Glass Description Attachment Method Type, Size, Building Product COOLER NAIL, 0.086" DIAMETER, 15/8" LONG, 15/64" HEAD; OR GYPSUM BOARD PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL CONTAIN ONLY NAIL, 0.086" DIAMETER, 15/8" LONG, 9/32" HEAD) SPACED AT 7" O.C. FOR NAILS NOTES: HIGH-EFFACY LAMPS. (LOW VOLTAGE LIGHTING SHALL NOT BE REQUIRED Spacing & Embedment Design Design WALLS AT Si:IOWER TO BE TILE. PROVIDE CEMENT, FIBER -CEMENT OR GLASS DIMENSIONS, CONDITIONS AT JOB SITE, PLANS, SPECIFICATIONS, ECT. RECESSED LIGHTING SHALL BE SEALED TO LIMIT AIR LEAKAGE BETWEEN MAT GYPSUM BACKERS IN COMPLIANCE WITH ASTM C 1288, C 1325, C 1178, OR 2) STRUCTURAL FEATURES NOT DETAILED ON THESE PLANS WILL BE CONDITIONED AND UNCONDITIONED SPACES, (DISTANCE FROM CORNER/ Pressure Pressure RECOMMENDATIONS AS BACKERS FOR WALL TILE INTUB AND SHOWER 3) ALL WRITTEN DIMENSIONS ON THESE DRAWINGS TAKE PRECEDENCE OVER SMOKE DETECTORS TO BE LOCATED AS SHOWN, AND INSIDE AND OUTSIDE OF - AREAS AND WALL PANELS IN SHOWER AREAS. (PER FRC 702.4.1 & FRC 702.4.2). SCALED DIMENSIONS. 4) DISTANCE O.C.) 4) ALL CONSTRUCTION MUST COMPLY WITH THE FLORIDA BUILDING CODE VERIFY. NOT GREATER THAN 450. (FBC) 2014, FBC 2014 RESIDENTIAL, FBC 2014 PLUMBING CODE, FBC 2014 S.H. _ SILVERLINE DETECTOR ACTIVATES ALL SMOKE DETECTORS IN THE RESIDENCE 1/4" X 11/4" MIN. EMBED ELCO 70) 2011 EDITION. 6) 1,2 FL# 14911.1 WINDOW 2901/4901 BLDG. NON -IMPACT ULTRACONS AT 2" / 4.5" O.C. SEE ELEVS +/-50 THE UNDERSIDE OF THE ROOF DECK OR ON THE ATTIC WALLS SHALL 2014 FOR EXISTING BUILDINGS. PROVIDE GROUND -FAULT CIRCUIT INTERRUPTER PROTECTION FOR ALL 125- COMPLY WITH SECTION FRC316. PRODUCTS 7) PER FRC 702.2.1 ALL GYPSUM BOARD MATERIALS AND ACCESSORIES SHALL - STRUCTURAL NOTES GARAGES, KITCHENS, ACCESORY BUILDINGS, OUTDOORS, OR WITHIN 72" OF CONFORM TO ASTM C 36, C 79, C 475, C 514, C 630, C 931, C 960, C 1002, C 1047, C 1) DESIGN LOADS IN ACCORDANCE WITH ASCE7-10. EDGE OF ANY SINK. 1177, C 1178, C 1278, C 1395, C 1396 OR C 1658 AND SHALL BE INSTALLED IN 2) SOIL BEARING CAPACITY: 2500 PSF (NIIN.). , CARBON MENOXIDE DETECTORS TO BE INSTALLED WITHIN 10' OF ALL # 8 X 11/2" MIN. EMBED 3) ALL LUMBER IN CONTACT WITH CONCRETE OR MASONRY SHALL BE BEDROOMS. 3 FL# 11136.2 S.C. DOOR 3068 OPAQUE JELD-WEN N/A SCREWS INTO BUCK AT SEE ELEVS +61-65 ASSEMBLIES, ROOF -CEILING ASSEMBLIES, WALL ASSEMBLIES, CRAWL 5) UNLESS OTHERWISE NOTED, THE INSTALLATION OF SPECIFIED HARDWARE AT THE TIME OF THE C.O. THERE MUST BE A CEILING FAN INSTALLER SPACES AND ATTICS SHALL HAVE A FLAME SPREAD INDEX NOT TO EXCEED 25 SHALL CONFORM TO THE MANUFACTURES INSTRUCTIONS AND STANDARD IN EACH OF THE BEDROOMS, AND A MINIMUM OF ONE CEILING FAN 6' 12.25 O.C. PRACTICIES. INSTALLED IN ALL PRIMARY LIVING AREAS Product Model # Manufacturer. Attachment Method Type, Building Product NAILS 6" O.C. EDGES, AND 6" O.C. FIELD, OR SCREWED WITH DRYWALL 1) RESIDENCE SHALL BE IN ACCORDANCE WITH FLORIDA BUILDING CODE 2014 Size; Spacing, Embedment & Stiffener etc. Design Design 7) EXTERIOR FRAME WALLS TO BE STUCCO OVER WIRELATH WITH I I GA. 2" 2) ATTIC ACCESS DOORS OR HATCHES FROM CONDITIOND SPACES TO LONG NAILS WITH 3/8" 0 HEAD @ 6" O.C. OVER (2) LAYERS OF (15# FELT OR Pressure Pressure Mullions N/A A LEVEL EQUIVALENT TO THE INSULATION ON THE SURROUNDING STUDS @ 6" O.C. PERIMETER AND FIELD. SURFACES, A WOOD FRAMED OR EQUIVALENT BAFFLE OR RETAINER IS Roof N/A REQUIRED TO BE PROVIDED WHEN LOOSE FILL IS INSTALLED, TO PREVENT GAGE), CORROSION -RESISTANT WEEP SCREED WITH A MINIMUM VERTICAL LOOSE FILL FROM SPILLING INTO THE LIVING SPACE. Soffit N/A THE BUILDING THERMAL ENVELOPE SHALL BE CONSTRUCTED TO LIMIT AIR BELOW THE FOUNDATION PLATE LINE ON EXTERIOR STUD WALLS IN LEAKAGE IN ACCORDANCE WITH THE REQUIREMENTS R402.4.1 THROUGH Hurricane R402.4.4. 1/4" X 2" EMBED ELCO PANELMATES OR TAPCONS AT 4) THE BUILDING SHALL BE TESTED FOR AIR LEAKAGE IN ACCORDANCE WITH Panels 9' FL# 11964.1 0.05 ALUM. EASTERN METAL SUPPLY 2" / 6" O.C. SEE ELEVS +/-40 span or less FOULTRATION RATE OF NO MORE THAN 0.3 CFM PER SQUARE FT, AND SHALL COVER AND TERMINATE ON THE ATTACHMENT FLANGE OF THE WEEP SWINGING DOORS NO MORE THAN 0.5 CFM PER SQUARE FT AND MUST BE I have reviewed the above product approval information and approve it. _ Name: Paul Welch P.E. I Certification Number: 29945 tcJ lu N I> O qz SCOPE F WORK WALL FINISH /INSULATION NOTES CONSTRUCT NEW GARAGE CONVERSION PER PLAN 1) INTERIOR TO BE %2" DRYWALL FINISH. M GAN 2) a� THIS IS AN ALTERATION LEVEL 2 AND MUST COMPLY WITH THE FBC 2014 FOR K L-L�E55 LONG, 1916411 BEAD; 0.098" DIAMETER,1 '/4" LONG, ANNULAR -RINGED; 5D wut¢N FIXTURES SHALL BE HIGH-EFFACY LAMPS OR A MINIMUM OF 75% OF THE COOLER NAIL, 0.086" DIAMETER, 15/8" LONG, 15/64" HEAD; OR GYPSUM BOARD SCOPE F WORK WALL FINISH /INSULATION NOTES CONSTRUCT NEW GARAGE CONVERSION PER PLAN 1) INTERIOR TO BE %2" DRYWALL FINISH. 2) ALL INTERIOR GYPSUM BOARD TO BE MIN. VP THICK WITH (13 GAGE, 13/8" THIS IS AN ALTERATION LEVEL 2 AND MUST COMPLY WITH THE FBC 2014 FOR A MINIMUM OF 75% OF THE LAMPS IN PERMANENTLY INSTALLED LIGHTING LONG, 1916411 BEAD; 0.098" DIAMETER,1 '/4" LONG, ANNULAR -RINGED; 5D EXISTING; BUILDINGS CHAPTER 7 AND 8. FIXTURES SHALL BE HIGH-EFFACY LAMPS OR A MINIMUM OF 75% OF THE COOLER NAIL, 0.086" DIAMETER, 15/8" LONG, 15/64" HEAD; OR GYPSUM BOARD PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL CONTAIN ONLY NAIL, 0.086" DIAMETER, 15/8" LONG, 9/32" HEAD) SPACED AT 7" O.C. FOR NAILS NOTES: HIGH-EFFACY LAMPS. (LOW VOLTAGE LIGHTING SHALL NOT BE REQUIRED AND 12" O.C. FOR SCREWS. 1) THE CONTRACTOR, SUBCONTRACTOR, SUPPLIER, ECT. SHALL VERIFY ALL. 3) WALLS AT Si:IOWER TO BE TILE. PROVIDE CEMENT, FIBER -CEMENT OR GLASS DIMENSIONS, CONDITIONS AT JOB SITE, PLANS, SPECIFICATIONS, ECT. RECESSED LIGHTING SHALL BE SEALED TO LIMIT AIR LEAKAGE BETWEEN MAT GYPSUM BACKERS IN COMPLIANCE WITH ASTM C 1288, C 1325, C 1178, OR 2) STRUCTURAL FEATURES NOT DETAILED ON THESE PLANS WILL BE CONDITIONED AND UNCONDITIONED SPACES, C 1278 AND INSTALLED IN ACCORDANCE WITH MANUFACTURERS' ADDRESSED BY THE ENGINEER AS CONSTRUCTION PROGRESSES. SMOKE DETECTORS TO BE I10V W/ BATTERY BACK UP -ARC FAULT CIRCUIT RECOMMENDATIONS AS BACKERS FOR WALL TILE INTUB AND SHOWER 3) ALL WRITTEN DIMENSIONS ON THESE DRAWINGS TAKE PRECEDENCE OVER SMOKE DETECTORS TO BE LOCATED AS SHOWN, AND INSIDE AND OUTSIDE OF - AREAS AND WALL PANELS IN SHOWER AREAS. (PER FRC 702.4.1 & FRC 702.4.2). SCALED DIMENSIONS. 4) WALL AND CEILING FINISHES SHALL HAVE A SMOKE -DEVELOPED INDEX OF 4) ALL CONSTRUCTION MUST COMPLY WITH THE FLORIDA BUILDING CODE VERIFY. NOT GREATER THAN 450. (FBC) 2014, FBC 2014 RESIDENTIAL, FBC 2014 PLUMBING CODE, FBC 2014 5) WALL AND CEILING FINISHES SHALL HAVE A FLAME -SPREAD MECHANICAL CODE, FBC 2014 ENERGY CONSERVATION, AND THE NEC (NFPA DETECTOR ACTIVATES ALL SMOKE DETECTORS IN THE RESIDENCE CLASSIFICATION OF NOT GREATER THAN 200. 70) 2011 EDITION. 6) ALL EXPOSED INSULATION MATERIALS INSTALLED ON ATTIC FLOORS SHALL 5) RESIDENCE LOCATED IN NEGLIGIBLE WEATHERING AREA, AND IN VERY HEAVY SERVING: FAAkMY, ROOMS, DINING ROOMS, LIVING ROOMS, PARLORS, HAVE A CRITICAL RADIANT FLUX NOT LESS THAN 0.12 WATT PER SQUARE TERMITE INFESTATION AREA PER FRC 301. LIBRARIES, DEl", BEDROOMS, SUNROOMS, RECREATION ROOMS, CLOSETS, CENTIMETER EXPOSED FOAM PLASTIC INSULATION MATERIALS EXPOSED TO 6) ALL ADDITIONS, REPAIRS, AND ALTERATIONS MUST COMPLY WrrH THE F.B.0 HALLWAYS, OR SOMAR ROOMS PER FBC AND NEC REQUIREMENTS. THE UNDERSIDE OF THE ROOF DECK OR ON THE ATTIC WALLS SHALL 2014 FOR EXISTING BUILDINGS. PROVIDE GROUND -FAULT CIRCUIT INTERRUPTER PROTECTION FOR ALL 125- COMPLY WITH SECTION FRC316. 7) PER FRC 702.2.1 ALL GYPSUM BOARD MATERIALS AND ACCESSORIES SHALL - STRUCTURAL NOTES GARAGES, KITCHENS, ACCESORY BUILDINGS, OUTDOORS, OR WITHIN 72" OF CONFORM TO ASTM C 36, C 79, C 475, C 514, C 630, C 931, C 960, C 1002, C 1047, C 1) DESIGN LOADS IN ACCORDANCE WITH ASCE7-10. EDGE OF ANY SINK. 1177, C 1178, C 1278, C 1395, C 1396 OR C 1658 AND SHALL BE INSTALLED IN 2) SOIL BEARING CAPACITY: 2500 PSF (NIIN.). , CARBON MENOXIDE DETECTORS TO BE INSTALLED WITHIN 10' OF ALL ACCORDANCE WITH THE PROVISIONS OF FRC, AND ADHESIVES FOR THE 3) ALL LUMBER IN CONTACT WITH CONCRETE OR MASONRY SHALL BE BEDROOMS. INSTALLATION OF GYPSUM BOARD SHALL CONFORM TO ASTM C 557 PRESSURE TREATED. 8) INSULATION MATERIALS, INCLUDING FACINGS, SUCH AS VAPOR RETARDERS 4) SPLTTING OR CRACKING OF STRUCTURAL COMPONENTS DUE TO PROVIDE TAMPER RESISTANT RECPTICLES PER NEC REQUIREMENTS OR VAPOR PERMEABLE MEMBRANES INSTALLED WITHIN FLOOR -CEILING - INSTALATION OF HARDWARE IS NOT PERMITED. - ASSEMBLIES, ROOF -CEILING ASSEMBLIES, WALL ASSEMBLIES, CRAWL 5) UNLESS OTHERWISE NOTED, THE INSTALLATION OF SPECIFIED HARDWARE AT THE TIME OF THE C.O. THERE MUST BE A CEILING FAN INSTALLER SPACES AND ATTICS SHALL HAVE A FLAME SPREAD INDEX NOT TO EXCEED 25 SHALL CONFORM TO THE MANUFACTURES INSTRUCTIONS AND STANDARD IN EACH OF THE BEDROOMS, AND A MINIMUM OF ONE CEILING FAN WITH AN ACCOMPANYING SMOKE -DEVELOPED INDEX NOT TO EXCEED 450 PRACTICIES. INSTALLED IN ALL PRIMARY LIVING AREAS WHEN TESTED IN ACCORDANCE WITH ASTM E 84 OR UL 723. " 6) UNLESS OTHERWISE NOTED FOR EXTERIOR WALLS, EXTERIOR PLYWOOD SHEATHING AND INTERIOR DRYWALL IS TO BE NAILED WITH 10d OR BETTER ENERGY CONSERVATION NOTES NAILS 6" O.C. EDGES, AND 6" O.C. FIELD, OR SCREWED WITH DRYWALL 1) RESIDENCE SHALL BE IN ACCORDANCE WITH FLORIDA BUILDING CODE 2014 - SCREWS 1.5" LONG AND 0.131 DIA. - ENERGY CONSERVATION RESIDENTIAL. 7) EXTERIOR FRAME WALLS TO BE STUCCO OVER WIRELATH WITH I I GA. 2" 2) ATTIC ACCESS DOORS OR HATCHES FROM CONDITIOND SPACES TO LONG NAILS WITH 3/8" 0 HEAD @ 6" O.C. OVER (2) LAYERS OF (15# FELT OR UNCONDrTIONED SPACES SHALL BE WEATHERSTRIPPED AND INSULATED TO TYVAK BUILDING WRAP) OVER 19/32" COX PLYWOOD WITH 10D NAILS TO A LEVEL EQUIVALENT TO THE INSULATION ON THE SURROUNDING STUDS @ 6" O.C. PERIMETER AND FIELD. SURFACES, A WOOD FRAMED OR EQUIVALENT BAFFLE OR RETAINER IS 8) WEEP SCREEDS. A MINIMUM 0.0194INCH (0.48 MM) (NO. 26 GALVANIZED SHEET REQUIRED TO BE PROVIDED WHEN LOOSE FILL IS INSTALLED, TO PREVENT GAGE), CORROSION -RESISTANT WEEP SCREED WITH A MINIMUM VERTICAL LOOSE FILL FROM SPILLING INTO THE LIVING SPACE. ATTACHMENT FLANGE OF 31/2 INCHES (89 MM) SHALL BE PROVIDED AT OR 3) THE BUILDING THERMAL ENVELOPE SHALL BE CONSTRUCTED TO LIMIT AIR BELOW THE FOUNDATION PLATE LINE ON EXTERIOR STUD WALLS IN LEAKAGE IN ACCORDANCE WITH THE REQUIREMENTS R402.4.1 THROUGH ACCORDANCE WITH ASTM C 926. THE WEEP SCREED SHALL BE PLACED A R402.4.4. MINIMUM OF 4 INCHES (102 MM) ABOVE THE EARTH OR 2 INCHES (51 MM) 4) THE BUILDING SHALL BE TESTED FOR AIR LEAKAGE IN ACCORDANCE WITH ABOVE PAVED AREAS AND BE OF A TYPE THAT WILL ALLOW TRAPPED WATER R402.4.1.2 TO DRAIN TO THE EXTERIOR OF THE BUILDING. THE WATER -RESISTIVE 5) WINDOWS, SKYLIGHTS, AND SLIDING GLASS DOORS SHALL HAVE AN AIR BARRIER SHALL LAP THE ATTACHMENT FLANGE. THE EXTERIOR LATH FOULTRATION RATE OF NO MORE THAN 0.3 CFM PER SQUARE FT, AND SHALL COVER AND TERMINATE ON THE ATTACHMENT FLANGE OF THE WEEP SWINGING DOORS NO MORE THAN 0.5 CFM PER SQUARE FT AND MUST BE SCREED. _ TESTED LISTED AND LABELED IN ACCORDANCE WITH R402.4.3. 6) CONTRACTOR SHALL PROVIDE ENERGY PERFORMANCE LEVEL (EPL) DISPLAY - CARD IN ACCORDANCE WITH FBC 2014 ENERGY CONSERVATION R401.3. " ELECTRICAL LOAD CALCIS ELECTRICAL KEY PER NEC SINGLE POLE SWITCH 558 S.F. @ 3 VA 1674 VA .. DRYER THREE WAY SWITCH 5000 3 RANGE 12000 WH DUPLEX CONVENIENCE OUTLET DW DVII 4500 I'IIN,�dT� O 120Y SPECIAL PURPOSE OUTLET EFRIG 1200 1200 11®Ni ® 220V OUTLET TOTAL 25574 VA �I LicHTFIaITDRE FIRST 10 KW @ 100% 10000 ❑ FANBOX/LIGHT REMAINDER( a 740% 6229.6 EXHAUST FAN TOTAL 16229.6 2 LAV - 1 GROUNDFAULT PROTECTION A/C HEAT fad 100% 5000- - �W WEATHERPROOF _3 TOTAL 21229.6 VA SMOKE DETECTOR 21229.6 O CARBON MONOXIDEDETECTOR 240 = 88 AMPS 3f rltQ�DI1�I$T�i;G, ❑D i EQUIPMENT DISCONNECT USE EXISTING 100 AMP SERVICE `ri Li I { i j,J ( 2 i5 3� 14 ELECTRICAL NOTES PLUMBING NOTES: 1) ALL ELECTRICAL WORK SHAL BE IN ACCORDANCE WITH THE NEC (NFPA 70) 1) ALL WORK SHALL BE IN ACCORDANCE WITH THE FBC 2014 -PLUMBING 2011 EDITION. 2) DW V PIPING SHALL BE SCHEDULE 40 PVC. 2) A MINIMUM OF 75% OF THE LAMPS IN PERMANENTLY INSTALLED LIGHTING 3) WATER PIPING IN BUILDING SHALL BE ONE OF THE FOLLOWING: TYPE L FIXTURES SHALL BE HIGH-EFFACY LAMPS OR A MINIMUM OF 75% OF THE COPPER CPVC, OR PEX. PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL CONTAIN ONLY 4) SLEEVE ALL PIPING IN CONTACT WITH CONCRETE OR UNDERGROUND HIGH-EFFACY LAMPS. (LOW VOLTAGE LIGHTING SHALL NOT BE REQUIRED WITHIN BLDG, TO BE HIGH-EFFACY LAMPS) 5) HOT WATER PIPING WITH A MINIMUM THERMAL RESISTANCE OF R-3 SHALL 3) RECESSED LIGHTING SHALL BE SEALED TO LIMIT AIR LEAKAGE BETWEEN BE APPLIED TO PIPING LARGER THAN 3/V NOMINAL DIAMETER, PIPING FROM CONDITIONED AND UNCONDITIONED SPACES, WATER HEATER TO KITCHEN OUTLETS, PIPING LOCATED OUTSIDE THE 4) SMOKE DETECTORS TO BE I10V W/ BATTERY BACK UP -ARC FAULT CIRCUIT CONDITIONED SPACE, PIPING FROM THE WATER HEATER TO THE 5) SMOKE DETECTORS TO BE LOCATED AS SHOWN, AND INSIDE AND OUTSIDE OF - DISTRIBUTION MANIFOLD, PIPING LOCATED UNDER THE FLOOR SLAB, ALL EXISTING BEDROOM INTERIOR DOORS (NOT SHOWN) IF NOT EXISTING BURRIED PIPING, SUPPLY AND RETUN PIPING IN RECIRCULATION SYSTEMS, VERIFY. PIPING WITH RUN LENGTHS GREATER THAN 20 FEET. 6) SMOKE DETECTORS TO BE INTERCONNECTED SO THAT ONE SMOKE 6) WATER BEATERS INSTALLED SHALL. BE IN ACCORDANCE WITH FBC 2014 DETECTOR ACTIVATES ALL SMOKE DETECTORS IN THE RESIDENCE ENERGY CONSERVATION. 7) PROVIDE BRANCH CIRCUIT ARC -FAULT PROTECTION FOR ALL CIRCUITS SERVING: FAAkMY, ROOMS, DINING ROOMS, LIVING ROOMS, PARLORS, LIBRARIES, DEl", BEDROOMS, SUNROOMS, RECREATION ROOMS, CLOSETS, HALLWAYS, OR SOMAR ROOMS PER FBC AND NEC REQUIREMENTS. 8) PROVIDE GROUND -FAULT CIRCUIT INTERRUPTER PROTECTION FOR ALL 125- VOLT, SINGLE-PHASE 15 AND 20 AMP CIRCUITS SREVING: BATHROOMS, - - GARAGES, KITCHENS, ACCESORY BUILDINGS, OUTDOORS, OR WITHIN 72" OF EDGE OF ANY SINK. 9) CARBON MENOXIDE DETECTORS TO BE INSTALLED WITHIN 10' OF ALL '. BEDROOMS. " 10) EXHAUST FANS TO BE VENTED THRU ROOF OR SOFFIT. 11) PROVIDE TAMPER RESISTANT RECPTICLES PER NEC REQUIREMENTS - - 12) TIE ELECTRICAL INTO EXISTING ELECTRICAL SERVICE. - 13) AT THE TIME OF THE C.O. THERE MUST BE A CEILING FAN INSTALLER IN EACH OF THE BEDROOMS, AND A MINIMUM OF ONE CEILING FAN _ INSTALLED IN ALL PRIMARY LIVING AREAS WINDOW/DOOR SCHEDULE 1 ----- 51" W X 48" H S.H. WINDOW 2 - 37 %" W X 63" H SH25 WINDOW 3 ----- 3 0 6 8 SOLID CORE DOOR A ----- 2 0 6 8 INTERIOR DOOR „ B ----- 3 0 6 8 BI -FOLD DOORS TABULATION EXIST. LIVING 2,271 S.F. (SraFzaTe TtNF5� NEW LIVING 558 S.F. TOTAL 2,829 S.F. - - - - - - PAUL WEl.ch+ DVCU MECHANICAL E'LE'CTR/CAL CIWL BNGINEE'RING I9B4S.W BIL. TWORE'ST. SUITE k r r4 PORT S7: LUCIE, ISL 3498.4 PHONE(772)785-98-68 MAIC, PINE'LCHINC@AOL.COA7 PA.IIL VVEE CH, P.E. FLS( RE'G A0. 29945 DEC 16 2916 SHEET 14MBER CIF I1��1J1-nflaJ - F'.'( 2iG 4" wapD -fo P — rLA'(j�- N+/ 5/0 X r. '/Z° � 6q2 (aylgLL 4t A WC44o — Pao �Th4T 2'i D•G. V &LA,S $GEILAW^ ATA.P&I F*,T; 2 K 4 "1'b E.K4ST vwe-U. ' 2^CtiN S,ft7&& W! "lb"x'3'!s" A..+LNOz kywTS \ - FYI 2.,k"O.0^!t'S'-•r• h.I1AF�o1J �4 vr/ ,. {�i131Nsu111'floll i61-1,Gad IJAIih h'rl.icc.p �i�1151-I - �T 1 Lo ZX4 Wacb fj{ Gati►t%I� — E���ieesoM PI&M w/ 4L � �iGIS'r N�rl r � � 1ll�iy X111 � 1 III" illi. �. %I ►1 liltl�l 11 PLYWOOD WALL SHEATIENG� GRADE D FELT PAPER PROVIDE BEAD OF SEALANT 3/4" FROM EDGE OF OPENING UNDERFELT APPLY FRLT TO EXTERIOR OF OPENING AND FOLD FELT OVER JAMBS DOOR OPENING WATERPROOFING (VOTES: CONTINUOUS FOAM INTERIOR AIR F'ASTENE.RS AS REQUIRED BY WINDOW MANUF'AC URER I. PRIOR TO BUCK INSTALLATION TREAT THE MASONRY OPENING WITH A CMU WATER AND WATER SEALANT PER ff'" RESISTANT COATING TO SEAL THE WINDOW / DOOR CAVITY. TO PREVENT IT FROM WATERPROOFING NOTE #5 CORROSION RESISTANT FLASHING PER WATERPRt OFING ABSORBING WATER. THE CMU WATER RESISTANT COATING SHALL BE APPLIED IN 101-- NOTE #2 { ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS. THE APPLICATION OF MARBLE SILL THE CMU WATER RESITANT COATING SHALL INCLUDE THE ENTIRE SURROUND OF THE i� CAULK SEAM AT WINDOW INSTALLATION OPENING (SILLS, JAMBS, HEAD) AND RETURN WALLS OF THE OPENING 24" MINIMUM '� (SEE WAILRPRpOFING NOTE #5) EACH DIRECTION, ALL CMU WATER RESISTANT COATINGS SHALL BE INSTALLED PRIOR _,_CMU WATER RESISTANT COATING TO BUCK INSTALLATIONS, MORTAR OR„";...... .,,, . (SEE WATERPRUOF'ING NO TE GROUT :7:. �;;,:;.:',.•..•::' 2. INSTALL BUCKS SO THAT THERE ARE NO EDGE GAPS EXCEEDING 1/8” BETWEEN :,.; ;y;-: `-- SET SILL IN FULL. MORTAR BED BUCK AND MASONRY. 3. PRIOR TO BUCK INSTALLATION APPLY 3/8" NOMINAL DIAMETER BEAD OF SEALANT Ji" DRYWALL — ^ --- STUCCO OR DECORATIVE CEMENTITIOUS COATING BETWEEN THE BUCK AND THE MASONRY TO PREVENT. THE PASSAGE OF LIQUID BEHIND THE BUCK. COMPLETELY SEAL THE ENTIRE END OF THE WOOD BUCKS WITH " - 8 C.M.U. SEALANT TO RESTRICT THE PASSAGE OF LIQUID THROUGH THE, CUT ENDS AND THE ENTIRE EXTERIOR. FACE AND RETURN SURFACE OF THE BUCK SHALL BE COATED 3/4" FURRING TO MASONRY WALL WITH A LIQUID APPLIED WATER RESISTIVE COATING / SEALANT. „ 4. PROVIDE PAN FLASHING AT SILL OF WINDOW AND DOOR OPENINGS. PAN FLASHING 4'' " SHALL BE SEALED OR SLOPED IN A MANNER TO DIRECT WATER TO THE SURFACE r OF THE EXTERIOR WATER RESISTIVE BARRIER FOR SUBSEQUENT DRAINAGE. - --•• INCORPORATE PAN FLASHING AT HEAD AND SILL AS WELL. PAN FLASHING SHALL INN, CORROSION RESISTANT. N - 1':"'' '� :'j r0 PRECAST CONCRETE WIND RESIS'fANj' FLUSH OR 5. PROVIDE CONTINUOUS.3/8" BEAD OF SEALANT ON WINDOW/ DOOR FRAMES AT ALL — OR A5 MANUFACTURERD BY CAST CRETE PERIMETER ON FRONT AND BACK SURFACE PRIOR TO WINDOW / DOOR ig' (OR ( EQUAL) INSTALLATION. 6. AFTER WINDOW/ DOOR INSTALLATION- PROVIDE FOAM SEALANT BETWEEN THE BUCK F►F�E�:�1T.•..l7NRETE WINICW._SIL»L I�TA�I (OR PRECAST SILL) AND THE WINDOW / DOOR TO ENSURE A WATER RESISTANT _.... INTERIOR AIR SEAL AROUND THE ENTIRE PERIMETER. —'- -- SCALE N.T„S. I . STUCCO CEMENT FINISH CMU WATER RESISTANT COATING FILLED CELL. AT JAMB BLOCK (TYP) 3 � -” (SEE WATERPROOFING NOTE #1) ­131-TWOOD WALL SMATTIF a s.. GRAVE DFELT PAPER(APPLIED LAST) CORROSION RESISTANT FLASHING o d _ pR(yi�IDEBEADOFSEALANT'K" PER WATERPROOFING NOTE #2 N j FROM EDGE OF OPENING UNDER FELT g o - �� 1x3 P.T. WOOD F'IRRING ALL (3) SIDES CONTINUOUS a. APPLY FELT TO EXTERIOR OF OPENING AND FOLD FELT OVER JAMBS WINDOW OPENING APPLY PERIMETER SEALANT CAULK --�r0 \ SEE WATER PROOFING NOTE #6 ' BETWEEN BUCK &WINDOW FRAME I OPADEDFELT PAPER SILL PANNING (SEE WATERPROOFING NOTE #5) (APplIED2n ANCHOR 1x4 P.T. (MIN.) BUCK WI1H SE LANT I`I vmoOVERENTIRESILL, OVER PER WATERPROOFING NOTE #4 AND AN HORF_0 LAPSILL PANNING 4"PROVIDE TO MASONRY WITH 1---h" CASE HARDENED 'COIL. i W-40OFSEALANT'/4"FROM EDGE NAILS 012" O.C. MAX.. ! OF OPENING UNDER FELT i I GRAM DFELT PAPER APPRON (APPLIED I') ANCHOR WINDOW FRAME 1O MASONRY 114 STRICT 'I 9r WIDE CONTINUOUS LINDER SILL PROVIDE ACCORDANCE WITH MANUFACTURE'S DUCT APPROVAL INS7ALLA'1'ION REQUIREMENT'T S —BEAD OF SEALANT '/s FROM EDGE OF OPENING UNDERFELT f WINDOW -'AME SHOULD 8E COMPLETL'i SEAT'" ON THE JCK, IN NO INSTANCE SHALL THE FRAME OVERHANG THE BUCK SHEEETTJNU14BER BOTTOM CORD OF -gv TRUSS' 1/x" DRYWALL (WALLS r ITF AND CLG) 2 X 4 WD TOP PLATE OR c 1 '/a" X 3 5/8" METAL RUNNER �., 2 X 4 WD STUDS a@ 24" lul O.C. b OR 1 %z" X 3 5/8" METAL STUDS @ 16" O.C. Y2" DRYWALL BOTH SIDES (SEE WALL FINISH i .a J NOTES FOR WALLS i ADJACENT TO SHOWER 'i AND TUB) 2X4 P.T. WD B017• PLATE h . OR I,W" X 3 5/8" METAL RUNNER W/ TAPCONS { @ 24" O.C. _,. CONC. FLOOR TV.' INTERIOR. NUN-BRG. WALL DETAIL ats... IN ; I I �jCJ FI0La I li . I: I1��1J1-nflaJ - F'.'( 2iG 4" wapD -fo P — rLA'(j�- N+/ 5/0 X r. '/Z° � 6q2 (aylgLL 4t A WC44o — Pao �Th4T 2'i D•G. V &LA,S $GEILAW^ ATA.P&I F*,T; 2 K 4 "1'b E.K4ST vwe-U. ' 2^CtiN S,ft7&& W! "lb"x'3'!s" A..+LNOz kywTS \ - FYI 2.,k"O.0^!t'S'-•r• h.I1AF�o1J �4 vr/ ,. {�i131Nsu111'floll i61-1,Gad IJAIih h'rl.icc.p �i�1151-I - �T 1 Lo ZX4 Wacb fj{ Gati►t%I� — E���ieesoM PI&M w/ 4L � �iGIS'r N�rl r � � 1ll�iy X111 � 1 III" illi. �. %I ►1 liltl�l 11 PLYWOOD WALL SHEATIENG� GRADE D FELT PAPER PROVIDE BEAD OF SEALANT 3/4" FROM EDGE OF OPENING UNDERFELT APPLY FRLT TO EXTERIOR OF OPENING AND FOLD FELT OVER JAMBS DOOR OPENING WATERPROOFING (VOTES: CONTINUOUS FOAM INTERIOR AIR F'ASTENE.RS AS REQUIRED BY WINDOW MANUF'AC URER I. PRIOR TO BUCK INSTALLATION TREAT THE MASONRY OPENING WITH A CMU WATER AND WATER SEALANT PER ff'" RESISTANT COATING TO SEAL THE WINDOW / DOOR CAVITY. TO PREVENT IT FROM WATERPROOFING NOTE #5 CORROSION RESISTANT FLASHING PER WATERPRt OFING ABSORBING WATER. THE CMU WATER RESISTANT COATING SHALL BE APPLIED IN 101-- NOTE #2 { ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS. THE APPLICATION OF MARBLE SILL THE CMU WATER RESITANT COATING SHALL INCLUDE THE ENTIRE SURROUND OF THE i� CAULK SEAM AT WINDOW INSTALLATION OPENING (SILLS, JAMBS, HEAD) AND RETURN WALLS OF THE OPENING 24" MINIMUM '� (SEE WAILRPRpOFING NOTE #5) EACH DIRECTION, ALL CMU WATER RESISTANT COATINGS SHALL BE INSTALLED PRIOR _,_CMU WATER RESISTANT COATING TO BUCK INSTALLATIONS, MORTAR OR„";...... .,,, . (SEE WATERPRUOF'ING NO TE GROUT :7:. �;;,:;.:',.•..•::' 2. INSTALL BUCKS SO THAT THERE ARE NO EDGE GAPS EXCEEDING 1/8” BETWEEN :,.; ;y;-: `-- SET SILL IN FULL. MORTAR BED BUCK AND MASONRY. 3. PRIOR TO BUCK INSTALLATION APPLY 3/8" NOMINAL DIAMETER BEAD OF SEALANT Ji" DRYWALL — ^ --- STUCCO OR DECORATIVE CEMENTITIOUS COATING BETWEEN THE BUCK AND THE MASONRY TO PREVENT. THE PASSAGE OF LIQUID BEHIND THE BUCK. COMPLETELY SEAL THE ENTIRE END OF THE WOOD BUCKS WITH " - 8 C.M.U. SEALANT TO RESTRICT THE PASSAGE OF LIQUID THROUGH THE, CUT ENDS AND THE ENTIRE EXTERIOR. FACE AND RETURN SURFACE OF THE BUCK SHALL BE COATED 3/4" FURRING TO MASONRY WALL WITH A LIQUID APPLIED WATER RESISTIVE COATING / SEALANT. „ 4. PROVIDE PAN FLASHING AT SILL OF WINDOW AND DOOR OPENINGS. PAN FLASHING 4'' " SHALL BE SEALED OR SLOPED IN A MANNER TO DIRECT WATER TO THE SURFACE r OF THE EXTERIOR WATER RESISTIVE BARRIER FOR SUBSEQUENT DRAINAGE. - --•• INCORPORATE PAN FLASHING AT HEAD AND SILL AS WELL. PAN FLASHING SHALL INN, CORROSION RESISTANT. N - 1':"'' '� :'j r0 PRECAST CONCRETE WIND RESIS'fANj' FLUSH OR 5. PROVIDE CONTINUOUS.3/8" BEAD OF SEALANT ON WINDOW/ DOOR FRAMES AT ALL — OR A5 MANUFACTURERD BY CAST CRETE PERIMETER ON FRONT AND BACK SURFACE PRIOR TO WINDOW / DOOR ig' (OR ( EQUAL) INSTALLATION. 6. AFTER WINDOW/ DOOR INSTALLATION- PROVIDE FOAM SEALANT BETWEEN THE BUCK F►F�E�:�1T.•..l7NRETE WINICW._SIL»L I�TA�I (OR PRECAST SILL) AND THE WINDOW / DOOR TO ENSURE A WATER RESISTANT _.... INTERIOR AIR SEAL AROUND THE ENTIRE PERIMETER. —'- -- SCALE N.T„S. I . STUCCO CEMENT FINISH CMU WATER RESISTANT COATING FILLED CELL. AT JAMB BLOCK (TYP) 3 � -” (SEE WATERPROOFING NOTE #1) ­131-TWOOD WALL SMATTIF a s.. GRAVE DFELT PAPER(APPLIED LAST) CORROSION RESISTANT FLASHING o d _ pR(yi�IDEBEADOFSEALANT'K" PER WATERPROOFING NOTE #2 N j FROM EDGE OF OPENING UNDER FELT g o - �� 1x3 P.T. WOOD F'IRRING ALL (3) SIDES CONTINUOUS a. APPLY FELT TO EXTERIOR OF OPENING AND FOLD FELT OVER JAMBS WINDOW OPENING APPLY PERIMETER SEALANT CAULK --�r0 \ SEE WATER PROOFING NOTE #6 ' BETWEEN BUCK &WINDOW FRAME I OPADEDFELT PAPER SILL PANNING (SEE WATERPROOFING NOTE #5) (APplIED2n ANCHOR 1x4 P.T. (MIN.) BUCK WI1H SE LANT I`I vmoOVERENTIRESILL, OVER PER WATERPROOFING NOTE #4 AND AN HORF_0 LAPSILL PANNING 4"PROVIDE TO MASONRY WITH 1---h" CASE HARDENED 'COIL. i W-40OFSEALANT'/4"FROM EDGE NAILS 012" O.C. MAX.. ! OF OPENING UNDER FELT i I GRAM DFELT PAPER APPRON (APPLIED I') ANCHOR WINDOW FRAME 1O MASONRY 114 STRICT 'I 9r WIDE CONTINUOUS LINDER SILL PROVIDE ACCORDANCE WITH MANUFACTURE'S DUCT APPROVAL INS7ALLA'1'ION REQUIREMENT'T S —BEAD OF SEALANT '/s FROM EDGE OF OPENING UNDERFELT f WINDOW -'AME SHOULD 8E COMPLETL'i SEAT'" ON THE JCK, IN NO INSTANCE SHALL THE FRAME OVERHANG THE BUCK SHEEETTJNU14BER