Loading...
HomeMy WebLinkAboutEnergy Calculation Form & Manual J's FORM R405-2014 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: DITTMER&SIEGAL RESIDENCE Builder Name: Street: APPALOOSA COURT Permit Office: City,State,Zip: PORT ST.LUCIE,FL, Permit Number. Owner: Jurisdiction: Design Location: FL,Fort Pierce County:: ST.LUCIE COUNTY(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types(2576.9 sqft.) Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Ext Insul,Exterior R=5.4 2576.90 ft2 b.N/A R= ft2 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms 3 d.N/A R= ft2 5. !s this a worst case? No 10.Ceiling Types (4147.0 sqft.) Insulation Area a.Under Attic(Vented) R=30.0 4147.00 ft2 6. Conditioned floor area above grade(ft2) 3999 b.N/A R= ft2 Conditioned floor area below grade(ft2) 0 c.N/A R= ft2 11.Ducts R ft2 .7. Windows(476.3 sqft.) Description Area a.Sup:Attic,Ret:Attic,AH:Garage 6 325 a. U-Factor: Dbl,U=0.34 243.00 ft2 b.Sup: Attic,Ret:Attic,AH:Garage 6 225 SHGC: SHGC=0.22 b. U-Factor: Dbl,U=0.32 173.33 ft2 12.Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.20 a.Central Unit 47.0 SEER:16.50 b.Central Unit 29.4 SEER:16.00 c. U-Factor: Dbl,U=0.21 40.00 ft2 SHGC: SHGC=0.10 13.Heating systems kBtu/hr Efficiency d. U-Factor: other(see details) 20.00 ft2 a.Electric Strip Heat 34.0 COP:1.00 SHGC: other(see details) b.Electric Strip Heat 27.0 COP:1.00 Area Weighted Average Overhang Depth: 7.707 ft. Area Weighted Average SHGC: 0.202 14.Hot water systems 8. Floor Types (3999.0 sqft.) Insulation Area a.Electric Cap:60 gallons EF:0.950 a.Slab-On-Grade Edge Insulation R=0.0 3999.00 ft2 b. Conservation features b.N/A R= ft2 None c.N/A R= ft2 15.Credits CF,Pstat Glass/Floor Area: 0.119 Total Proposed Modified Loads: 101.27 PASS Total Baseline Loads: 104.88 1 hereby certify that the plans and specifications covered by Review of the plans and Z8E Sr�q?, this calculation are in compliance with the Florida Energy specifications covered by this 1•� 950�, Code. calculation indicates complianceii„ �+ with the Florida Energy Code. rrrrrrJ'� �� O PREP RERB . Before construction is completed DATE this building will be inspected for compliance with Section 553.908 * II I hereby certify that this building,as designed,is in compliance Florida Statutes. with the Florida Energy Code. COD WE'T�� OWNER/AGENT: BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handier enclosure qualifies as certified factory-sealed in accordance with R403.2.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage test report in accordance with R402.4.1.2. 'a 0 LF L; a 11/22/2016 8:14 AM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 6 FORM R405-2014 PROJECT Title: DITTMER&SIEGAL RESIDE Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 3999 Lot# Owner: Total Stories: 1 Block/SubDivision: #of Units: 1 Worst Case: No PlatBook: Builder Name: Rotate Angle: 0 Street: APPALOOSA COURT Permit Office: Cross Ventilation: No County: ST.LUCIE COUNTY Jurisdiction: Whole House Fan: No City,State,Zip: PORT ST.LUCIE, Family Type: Single-family FL, New/Existing: New(From Plans) Comment: CLIMATE IECC Design Temp Int Design Temp Heating Design Daily Temp \/ Design Location TMY Site Zone 97.5% 2.5% Winter Summer Degree Days Moisture Range FL,Fort Pierce FL VERO_BEACH_MUNI 2 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 AHU#1 2417 21148.6 2 AHU#2 1582 12656 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 GREAT ROOM 954 9444.6 No 2 1 Yes Yes Yes 2 DINING ROOM 255 2040 No 0 1 Yes Yes Yes 3 KITCHEN 240 1920 Yes 0 1 No Yes Yes 4 OFFICE 170 1360 No 0 1 Yes Yes Yes 5 BEDROOM#2 289 2312 No 1 1 1 Yes Yes Yes 6 BATH 2 104 832 No 0 1 Yes Yes Yes 7 BEDROOM#3 289 2312 No 1 1 1 Yes Yes Yes 8 HALL 32 256 No 0 1 No Yes Yes 9 BATH 84 672 No 0 1 Yes Yes Yes 10 MASTER BEDROO 522 4176 No 2 1 1 Yes Yes Yes 11 WIC 48 384 No 0 1 Yes Yes Yes 12 WIC 2 48 384 No 0 1 No Yes Yes 13 MASTER BATH 256 2048 No 0 1 Yes Yes Yes 14 MUSIC ROOM 336 2688 No 2 1 Yes Yes Yes 15 LAUNDRY 160 1280 No 0 1 Yes Yes Yes 16 HALLWAY 212 1696 No 0 1 Yes Yes Yes 11/22/2016 8:14 AM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 6 FORM R405-2014 FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab-On-Grade Edge Insulatio GREAT ROOM 48 ft 0 954 ft2 0 1 0 2 Slab-On-Grade Edge Insulatio DINING ROOM 19 ft 0 255 ft2 0 1 0 3 Slab-On-Grade Edge Insulatio KITCHEN 1 ft 0 240 ft2 — 0 1 0 4 Slab-On-Grade Edge Insulatio OFFICE 16 ft 0 170 ft2 — 0 1 0 5 Slab-On-Grade Edge Insulatio BEDROOM#2 40 ft 0 289 ft2 — 0 1 0 6 Slab-On-Grade Edge Insulatio BATH 2 8 ft 0 104 ft2 — 0 1 0 7 Slab-On-Grade Edge Insulatio BEDROOM#3 27 ft 0 289 ft2 — 0 1 0 8 Slab-On-Grade Edge Insulatio HALL 1 ft 0 32 ft2 ____ 0 1 0 9 Slab-On-Grade Edge Insulatio BATH 31 ft 0 84 ft2 — 0 1 0 10SIab-On-Grade Edge Insulatio MASTER BEDRO 74 ft 0 522 ft2 — 0 1 0 11Slab-On-Grade Edge Insulatio WIC 8 ft 0 48 ft2 — 0 1 0 12SIab-On-Grade Edge Insulatio WIC 2 1 ft 0 48 ft2 ____ 0 1 0 13SIab-On-Grade Edge Insulatio MASTER BATH 14 ft 0 256 ft2 0 1 0 14SIab-On-Grade Edge Insulatio MUSIC ROOM 21 It 0 336 ft2 0 1 0 15SIab-On-Grade Edge Insulatio LAUNDRY loft 0 160 ft2 0 1 0 16SIab-On-Grade Edge Insulatio HALLWAY Eft 0 212 ft2 0 1 0 ROOF Roof • Gable Roof Solar SA Emitt Emitt Deck Pitch # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Gable or Shed Composition shingles 4214 ft2 666 ft2 Medium 0.6 No 0.9 No 0 18.4 ATTIC V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC 1 Full attic Vented 300 3999 ft2 N N 11/22/2016 8:14 AM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 6 FORM R405-2014 CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic(Vented) GREAT ROOM 30 Blown 201 ft2 0.1 Wood 2 Under Attic(Vented) GREAT ROOM 30 Blown 900 ft2 0 Wood 3 Under Attic(Vented) DINING ROOM 30 Blown 255 ft2 0.1 Wood 4 Under Attic(Vented) KITCHEN 30 Blown 240 ft2 0.1 Wood 5 Under Attic(Vented) OFFICE 30 Blown 167 ft2 0.1 Wood 6 Under Attic(Vented) OFFICE 30 Blown 4 ft2 0 Wood 7 Under Attic(Vented) BEDROOM#2 30 Blown 289 ft2 0.1 Wood 8 Under Attic(Vented) BATH 2 30 Blown 104 ft2 0.1 Wood 9 Under Attic(Vented) BEDROOM#3 30 Blown 289 ft2 0.1 Wood 10 Under Attic(Vented) HALL 30 Blown 32 ft2 0.1 Wood 11 Under Attic(Vented) BATH 30 Blown 84 ft2 0.1 Wood 12 Under Attic(Vented) MASTER BEDRO 30 Blown 522 ft2 0.1 Wood 13 Under Attic(Vented) WIC 30 Blown 48 ft2 0.1 Wood 14 Under Attic(Vented) WIC 2 30 Blown 48 ft2 0.1 Wood 15 Under Attic(Vented) MASTER BATH 30 Blown 256 ft2 0.1 Wood 16 Under Attic(Vented) MUSIC ROOM 30 Blown 336 ft2 0.1 Wood 17 Under Attic(Vented) LAUNDRY 30 Blown 160 ft2 0.1 Wood 18 Under Attic(Vented) HALLWAY 30 Blown 212 ft2 0.1 Wood WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below Omt To Wall Type Space R-Value Et In Et In Area R--Val,e Fraction Ahsor Grade%- I E Exterior Concrete Block-Ext In38REAT ROO 5.4 20 2 9 11 200.0 ft2 0 0 0.6 0 2 W Exterior Concrete Block-Ext InGREAT ROO 5.4 18 7 9 11 184.3 ft2 0 0 0.6 0 3 N Exterior Concrete Block-Ext InMINING ROO 5.4 4 0 8 0 32.0 ft2 0 0 0.6 0 4 E Exterior Concrete Block-Ext InONING ROO 5.4 15 0 8 0 120.0 ft2 0 0 0.6 0 5 N Exterior Concrete Block-Ext InsulOFFICE 5.4 7 0 8 1 56.6 ft2 0 0 0.6 0 6 W Exterior Concrete Block-Ext InsulOFFICE 5.4 8 11 8 1 72.1 ft2 0 0 0.6 0 7 N Exterior Concrete Block-Ext InfiffDROOM# 5.4 17 0 8 0 136.0 ft2 0 0 0.6 0 8 S Exterior Concrete Block-Ext InSEDROOM# 5.4 6 0 8 0 48.0 ft2 0 0 0.6 0 9 W Exterior Concrete Block-Ext InfiffDROOM# 5.4 17 0 8 0 136.0 ft2 0 0 0.6 0 10 N Exterior Concrete Block-Ext Insul BATH 2 5.4 8 0 8 0 64.0 ft2 0 0 0.6 0 11 N Exterior Concrete Block-Ext InfiffDROOM# 5.4 17 0 8 0 136.0 ft2 0 0 0.6 0 12 E Exterior Concrete Block-Ext InMEDROOM# 5.4 10 0 8 0 80.0 ft2 0 0 0.6 0 13 N Exterior Concrete Block-Ext Insul BATH 5.4 12 0 8 0 96.0 ft2 0 0 0.6 0 14 E Exterior Concrete Block-Ext Insul BATH 5.4 7 0 8 0 56.0 ft2 0 0 0.6 0 15 S Exterior Concrete Block-Ext Insul BATH 5.4 12 0 8 0 96.0 ft2 0 0 0.6 0 16 N Exterior Concrete Block-Ext IndUASTER BE 5.4 27 0 8 0 216.0 ft2 0 0 0.6 0 17 E Exterior Concrete Block-Ext Ins)AASTER BE 5.4 20 0 8 0 160.0 ft2 0 0 0.6 0 18 S Exterior Concrete Block-Ext InddASTER BE 5.4 27 0 8 0 216.0 ft2 0 0 0.6 0 19 S Exterior Concrete Block-Ext Insul WIC 5.4 8 0 8 0 64.0 ft2 0 0 0.6 0 20 S Exterior Concrete Block-Ext InddASTER BA 5.4 14 0 8 0 112.0 ft2 0 0 0.6 0 21 S Exterior Concrete Block-Ext InddUSIC ROO 5.4 21 0 8 0 168.0 ft2 0 0 0.6 0 22 S Exterior Concrete Block-Ext InSd1AUNDRY 5.4 10 0 8 0 80.0 ft2 0 0 0.6 0 11/22/2016 8:14 AM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 6 FORM R405-2014 WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below rnt To Wall T� Space 13-Atalue Et In Et In Area R ualue-Fraction--Absor-Grade'/ _23 N Exterior Concrete Block-Ext InsdHALLWAY 5.4 6 0 8 0 48.0 ft2 0 0 0.6 0 DOORS # Omt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 S Insulated BATH None .39 3 6 10 20.5 ft2 2 S Insulated LAUNDRY None .39 2 10 6 10 19.4 ft2 WINDOWS Orientation shown is the entered,Proposed orientation. Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening 1 E 1 Vinyl Low-E Double Yes 0.28 0.21 20.0 ft2 12 ft 0 in 1 ft 4 in None None 2 E 1 Vinyl Low-E Double Yes 0.32 0.2 80.0 ft2 12 ft 0 in 1 ft 4 in None None 3 W 2 Vinyl Low-E Double Yes 0.21 0.1 40.0 ft2 12 ft 0 in 1 ft 4 in None None 4 W 2 Vinyl Low-E Double Yes 0.34 0.22 30.0 ft2 8 ft 10 in 1 ft 4 in None None 5 E 4 Vinyl Low-E Double Yes 0.34 0.22 30.0 ft2 8 ft 0 in 1 ft 4 in None None 6 W 6 Vinyl Low-E Double Yes 0.34 0.22 15.0 ft2 2 ft 0 in 1 It 4 in None None 7 W 9 Vinyl Low-E Double Yes 0.34 0.22 30.0 ft2 2 ft 0 in 1 ft 4 in None None 8 N 10 Vinyl Low-E Double Yes 0.34 0.22 9.0 ft2 2 ft 0 in 1 ft 4 in None None 9 N 11 Vinyl Low-E Double Yes 0.34 0.22 30.0 ft2 2 ft 0 in 1 ft 4 in None None 10 E 12 Vinyl Low-E Double Yes 0.32 0.2 40.0 ft2 12 ft 0 in 1 ft 4 in None None 11 N 13 Vinyl Low-E Double Yes 0.34 0.22 6.0 ft2 2 ft 0.in 1 ft 4 in None None 12 N 16 Vinyl Low-E Double Yes 0.32 0.2 53.3 ft2 12 ft 0 in 1 ft 4 in None None 13 E 17 Vinyl Low-E Double Yes 0.34 0.22 30.0 ft2 2 ft 0 in 1 ft 4 in None None 14 S 18 Vinyl Low E Double Yes 0.34 0.22 15.0 ft2 2 ft 0 in 1 ft 4 in None None 15 S 20 Vinyl Low-E Double Yes 0.34 0.22 6.0 ft2 2 ft 0 in 1 ft 4 in None None- 16 S 20 Vinyl Low-E Double Yes 0.34 0.22 12.0 ft2 2 ft 0 in 1 ft 4 in None None 17 S 21 Vinyl Low-E Double Yes 0.34 0.22 30.0 ft2 2 ft 0 in 1 ft 4 in None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation 1 986 ft2 986 ft2 29 ft 8 ft 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000376 3943.9 216.51 407.18 .2745 7 11/22/2016 8:14 AM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 6 of 6 FORM R405-2014 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Strip Heat None COPA 34 kBtu/hr 1 sys#1 2 Electric Strip Heat None COPA 27 kBtu/hr 2 sys#2 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit Split SEER:16.5 47 kBtu/hr cfm 0.7 1 sys#1 2 Central Unit Split SEER:16 29.4 kBtu/hr cfm 0.7 2 sys#2 HOT WATER SYSTEM # System Type SubType Location EF Cap ' Use SetPnt Conservation 1 Electric None Garage 0.95 60 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model# Collector Model# Area Volume FEF None None ft2 DUCTS —Supply— —Return— Air CFM 25 CFM25 HVAC# V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 325 ft2 Attic 105 ft2 Default Leakage Garage (Default) (Default) 1 1 2 Attic 6 225 ft2 Attic 75 ft2 Default Leakage Garage (Default) (Default) 2 2 TEMPERATURES Programable Thermostat:Y Ceiling Fans: ri N Dec Heat ng Jan []Feb Mar Apr MaApr I j y JXJ Jun LX]Jul rj AuOct ov g Sep L 1 Occtt X Nov DecVenting Jan Feb Mar Jun [ Jul Aug Sep LXJ Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 66 68 68 68 68 66 66 Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 11/22/2016 8:14 AM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 6 of 6 FORM R405-2014 TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: DITTMER&SIEGAL RESIDENCE Builder Name: Street: APPALOOSA COURT Permit Office: City,State,Zip: PORT ST.LUCIE,FL, Permit Number: Owner. Jurisdiction: Design Location: FL,Fort Pierce COMPONENT CRITERIA CHECK Air barrier and thermal barrier A continuous air barrier shall be installed in the building envelope. Exterior thermal envelope contains a continuous barrier. Breaks or joints in the air barrier shall be sealed. Air-permeable insulation shall not be used as a sealing material. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the insulation and any gaps in the air barrier shall be sealed. Access openings,drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Comers and headers shall be insulated and the junction of the foundation Walls and sill plate shall be sealed. The junction of the top plate and the top or exterior walls shall be sealed. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Knee walls shall be sealed. Windows, skylights and doors The space between window/door jambs and framing and skylights and framing shall be sealed. Rim joists Rim joists are insulated and include an air barrier. Floors (including above-garage Insulation shall be installed to maintain permanent contact with underside and cantilevered floors) of subfloor decking. The air barrier shall be installed at any exposed edge of insulation. Crawl space walls Where provided in lieu of floor insulation,insulation shall be permanently attached to the crawlspace walls. Exposed earth in unvented crawl spaces shall be covered with a Class I vapor retarder with overlapping joints taped. Shafts, penetrations Duct shafts, utility penetrations,and flue shaft openings to exterior or unconditioned space shall be sealed. Narrow cavities Batts in narrow cavities shall be cut to fit,or narrow cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal envelope shall be air tight, IC rated,and sealed to the drywall. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls,or insulation that on installation readily conforms to available space shall extend behind piping and wiring. Shower/tub on exterior wall Exterior walls adjacent to showers and tubs shall be insulated and the air barrier installed separating them from the showers and tubs. Electrical/phone box on The air barrier shall be installed behind electrical or communication boxes or air sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub-floor or drywall. Fireplace An air barrier shall be installed on fireplace walls.Fireplaces shall have gasketed doors 11/22/2016 8:14 AM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 1