HomeMy WebLinkAboutEnergy Calculation Form & Manual J's U
A LIM
FLORIDA BUILDING CODE, ENERGY CONSERVA 711W
r
Residential Building Thermal Envelope Approach I
FORM 8402-2014 Climate Zone 0 1 1
Scope.Compliance with Section R402.1.1 of the Florida Building Code,Energy Conservation..shall be demonstrated by the use of Form R402
for single-and multiple4amily residences of three stories or less in height,additions to existing residential buildings,alterations,renovations,
and building systems in existing buildings,as applicable.To comply,a building must meet or exceed all of the energy efficiency requirements
on Table R402A and all applicable mandatory requirements summarized in Table 8402B of this form.If a building does not comply with this
method,or by the UA Alternative method,it may still comply under Section R405 of the Florida Building Code.Energy Conservation.
PROJECT NAME:C)15()r) BUILDER:
AND ADDRESS: 01505 ruo.
OWNER: PERMITTING OFFICE.
%-u4c.CJDL�Aodcva-, JURISDICTION NUMBER: tI
PERMIT NUMBER:
General Instructions:
1.Fill in all the applicable spaces of the"To Be Installed`column on Table R402A with the Information requested.All"To Be Installed"values must be
equal to or more efficient than the required levels.
2.Complete page I based on the"To Be Installed'column information.
3.Read the requirements of Table R402B and check each box to Indicate your intent to comply with all applicable items.
4.Read,sign and date the"Prepared By"certification statement at the bottom of page 1.The owner or owner's agent must also sign and date the form_
1. New construction.addition,or existing building I til i!H nn
1 Single-family detached or multiple-family attached 2. N Dal r.
3. If multiple-family,number of units covered by this submission 3.
4. Is this a worst case?(yesfho) 4.
S. Conditioned floor area(sq.ft.) S.
6. Windows,"and area
a) U-factor: 6a.
b) Solar Heat Gain coefficient(SHeC) 6b.
c) Area 6c,
7. Skylights
a) LI-factor. 73.
b) Solar Heat Gain Coefficient(SHGC) 7b.
S. Floor type,area or perimeter,and insulation; P3
a) Slab-on-grado(R-value) ea. S66
b) Wood,raised(R-Yafue) 8b.
.c) Wood,common(FiLvalue) sc.
d) Concrete.raised(R-value) lid.
a) concrete,common(R-value) 8e.
9. Wall type and insulation.,
a) Exterior. 1. Wood frame(Insulation R-value) 9al.
2. Masonry(insulation R-value) 9a2.
b) Adjacent: 1. Wood frame(Insulation R-value) 9111.
2. Masonry(insulation R-value) 9b2.
10, Coiling type and Insulation
a) Attic(insulation R-value) 10a.
b) Single assembly(Insulation P-vatue) lob.
11. Air distribution system: its. C
a) Duct location,Insulation
b) AHU location 11b.
c) Total duct leakage.TW teport attached. 110. clailloo s.f. Yes
12. Cooling system: a)type 12a. er
T!Ivr
b)efficiency 12b. -A-(
13. Heating system, a)type 13a. e_11eC:k6C_
tp-
b)stfidencT. 13b- %_0
14, HVAC sizing calculation:attached 14- - - --Yes 0 No M--
15.Water heating system: a)type I Sa. e-N
b)efficiency 15b.
I hereby certify that the pt and specifications covered by this form are Review of plans and specifications covered by this form indicate
In compliance FIZ the a Bujjdinq,065.En rgy Conservation, compliance with the Florida BultdinQ Code,Energy Conservation.Before
PREPARED BY; Date.1.8_,_Ne1NQ0r)construction is complete,this building will be inspected for compliance In
h.AI -in compliance with the Florida Building accordance with Section 553.905,F.S.
I hereby certify the is b di CODE OF FICIAL*---.--
Code,Energy Cons*rVatldn.
OWNERIAGENT-.- Date: Date;._.
FLORIDA. BUILDING CODE-ENERGY CONSERVATION,5th EDITION(2014) R-C.3
TABLE 8402A _ �� +
BUILDING COMPONENT PRESCRIPTIVE REQUIREMENTS' til(VSTbLLEDIA,tdlESj R
[ Climate Zone 1 Climate Zone 2 - I`�
( Windows: U-Faclor=0.652 U-Factor=0.402 U-Factor=C.0 5
[ SHGC=0.25 SHGC:=0.25 SHGC=0.A,5
Skylights U-factor=0.75 ()-factor=0.65 U-tactor= 15
( SHGC=0.30 SHGC•=0.30 SHGC=0,3O
[ Doors:Exterior door LI-factor=0.65' IJ-facto•=0.40' U-faclor= O.f7s
[ Floors:
Slab-on-Grade NR NR
( Over unconditioned spaces' R-13 R-13 A-Value=)1
[ Oalls':Ext.and Adj.
Frame R-13 R-13 R-Value= 3
( Mass
Insulation on wall interior. R-4 R-6 R-Value=�}
( Insulation on wall exterior R-3 R-4 R-Value=?�
( Ceilings°; R=30 R=38 R-Value=
( Air infiltration: ;Blower door test is required on the building envelope to verify leakage 5 5 ACH; Total leakage=ACH
=test report provided to code official. Test re rt At d?
( Yes S No
[ Air distribution system°:
Air handling unit Not allowed in attic Location:
( Duct R value R-value?R-8(supply in attics)or>_R-6(all other duct locations)- R-Value=�j
( Air leakage:
( Duct test Postconstruction test Total leakage:5 4 cfm/100 s.f. Total leakage=, cfm/100s.1.
Rough-in test Total leakage S 3 cfm/100 s.t. Test report Atlached? Yes❑ Noji�
( Ducts in conditioned space Test not required if all ducts and AHU are in conditioned space Location:
( Air conditioning system: Minimum lederal standard required by NAECA'.
Central system S 65,000 Btu/h SEER 13.0 SEER= lL(
Room unit or PTAC EER(front Table C403.2.3(3)) EER=
( Other See Tables C403.2.3(1)-(11)
Heating system- 1 Minimum federal standard required by NAECAG
[ Heat pump<65,000 6tu/h HSPF 7.7(before 1,1/15);HSPF 8.2(as of 111115) HSPF= •`d—
Gas furnace,non-weatherized AFUE 80% AFUE=�grc
( Oil furnace.node-weatherized AFUE 83% AFUE=
( Other:
Water heating system(storage type): Minimum federal standard required by NAECA'
Electric' 40 gat:EF=0.92 Gallons-5 0
( 50 gal:EF=0.90 _ EF-0-16
Gas fired' 40 gal:EF-0.59 Gallons=
( 50 gal:EF=0.5B EF=
Other(describe):
(
[ XK=No rcY(iinement.
01 idavh component present in the As Proposed home must meet or exceed each of the applicahle perfcrmnnce criteria in order to comply with this code using
( this method.
( (2)For impact rated fenestration complying with Section 11301.2.1.2 of'the Plor(chr Building Code.Residential or Section 1609.1.2 of the Florida Building Code,
Brtilding the maximum U-factor shall be 0.75 in Climate Zone I and 0.65 in Climate Zane 2. An arta-weighted average of fl-factor and STIGC shall be
accepted to meet the requirements.or up to 15 square feed of elated fenestration area are exempted from the U-factor and SHGC requirement based on
[ Sections R402.3.1,R402.3.2 and R402.3.3.
(3)One side-hinged opaque door assembly up to 24 square feet is exempted from this L'-factor requirement.
[ (4)R-values are for insulation materia) only its applied in accordance with manufacturer: installation instructions. For mass walls. the "interior of wall'
requirement must be met except ifat least 50 perccnc of the insulation required for the"exterior of wall"is installed exteriorof,or integral to.the wall.
(5)Ducts&AMU installed--substantially leak free'-per Section R403.2.2.Test required by an energy rater certified in accordance with Section 553.99.Florida
( Statures,or to authorised by Florida Suvutex.'[he total leakage teat is not required for duets and air handlers located entirely within the building thermal
[ envelope.
16) minimus,ell iciencies are those%LE by the AlarionalAppUarrre F.uergy Consenwrion Ac•t of 1987 for typical residential equipment and arc subject to NAECA
rule,, and regulations. For other types of equipment, ccc Tables C403.2.30-1 I-1 1) of the Commercial Pruvisioits of the Florida Buileling Cade. Energy
[ Conseriyuh a.
17)For other electric storage volumes.min.EF=0.97-(0.00132*volume).
[ (3)For other natural gas storage volumes,min.FF=U.67-(0.0019 x volume).
R-CA FLORIDA BUILDING CODE-»ENERGY CONSERVATION,5th EDITION(2014)
TABLE R4028 MANDATORY REQUIREMENTS
u,
r Component Section Summary of Requirement(s) °" ry Check
Air leakage R402.4 To be caulked,gasketed,weatherstripped or otherwise sealed per Table R402.4.1.1.Recessed lighting:IC-rated as
having 5 2.0 cfm tested to ASTM E 283. '
Windows and doors:0.3 cfrrL.sq.ti(swinging doors:0.5 cfmfsf)when tested to NFRC 400 or AAMAANDMA/CSA 1011
I.S.2'A440.
Fireplaces:Tight-rdling flue dampers&outdoor combustion air. '
Programmable R403.1.2 Where forced air furnace is primary system,a programmable thermostat is required.
thermostat
Air distribution system A403.22 Ducts shall be tested to Section 803 of the RESNET standards by an energy rater certified in accordance with 1
R4032.4 Section 553.99.Florida Statutes,or as authorized by Florida Statutes Air handling units are not allowed in attics.
Water heaters R403.4 Comply with efficiencies in Table 0404.2.Hot water pipes insulated to>_R-3 to kitchen outlets,other cases.
Circulating systems to have an automatic or accessible manual OFF switch.Heat trap required for vertical pipe '
risers.
Swimming pools&spas R403.9 Spas and heated pools must have vapor-retardant covers or a liquid cover or other means proven to reduce heat
loss except it 709%of heat from site-recovered energy.Offttimer switch required.Gas heaters minimum thermal '
efficiency is 82%.Heal pump pool heaters minimum COP is 4.0.
Cooling/heating R403.6 Sizing calculation performed&attached.Special occasion cooling or heating capacity requires separate system or
equipment variable capacity system.
Lighting equipment R404.1 At least 75%of permanently installed lighting fixtlrres shall be high-efficacy lamps.
FLORIDA BUILDING CODE—ENERGY CONSERVATION,5th EDITION(2014) R-C.5