Loading...
HomeMy WebLinkAboutProduct Approval (2) Florida Building Code Online _ --77etK v+�.a j 'x P t y• u o la1ym''.1I(f ,f,,(R s g Y�n �S . i • BCIS Home Log In i User Registration I Hot Topics Submit Surcharge Stats&Facts i Publications FBC Staff BCIS Site Map Links i Search c ida . I, a� Product Approval USER:Public User Product Approval Menu>Product or Application Search>Application List>Application Detail >? a c b4 FL# FL11842-R3 - Application Type Revision Code Version 2014 Application Status Approved Comments Archived ❑ Product Manufacturer MFM Building Products Corp. Address/Phone/Email 525 Orange St. P.O. Box 340 Coshocton,OH 43812 (740) 622-2645 wcroft@mfmbp.com Authorized Signature James Buckner jimmy@cbuckinc.net Technical Representative Whit Croft Address/Phone/Email PO Box 340 Coshocton,OH 43812 (740) 622-2645 Ext 118 wcroft@mfmbp.com Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Underlayments Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer R Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed James L. Bucker,P.E.@ CBUCK Engineering the Evaluation Report Florida License PE-31242 Quality Assurance Entity Keystone Certifications,Inc. Quality Assurance Contract Expiration Date 12/31/2019 Validated By Steven M. Urich,PE Validation Checklist- Hardcopy Received Certificate of Independence FL11842 R3 COI CertOfIndeo.Ddf Referenced Standard and Year (of Standard) Standard Year ASTM D 1970 2009 Equivalence of Product Standards Certified By Florida Licensed Professional Engineer or Architect FL11842 R3 Eouiv Test Standard Eouiv.pdf Sections from the Code http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDqub%2fM2eroZG... 3/3/2017 Florida Building Code Online Page 2 of 3 Product Approval Method Method 1 Option D Date Submitted 04/16/2015 Date Validated 04/23/2015 Date Pending FBC Approval 04/25/2015 Date Approved 06/22/2015 Summary of Products FL# Model, Number or Name Description 11842.1 1-"IB3","IB3 Storm Stopper","IB3 Self-Adhered Roof Underlayments attached to Plywood Deck Shingle Starter","IB4 StormStopper"&"Shingle Starter" Limits of Use Installation Instructions Approved for use in HVHZ: No FL11842 R3 II 1 IB3Family EVALREPORT.Ddf. Approved for use outside HVHZ: Yes Verified By: James L. Buckner, P.E. @ CBUCK,Inc P.E. Impact Resistant: N/A #31242 Design Pressure: N/A Created by Independent Third Party: Yes Other: Refer to Evaluation Report for Limitations and Evaluation Reports Conditions of Use.Refer to Manufacturer's Installation FL11842 R3 AE 1 IB3Family EVALREPORT.Ddf Instructions as a supplemental guide for attachment. Created by Independent Third Party: Yes 11842.2 2-"Peel&Seal" Self-Adhered Roof Underlayment attached to Plywood Deck Limits of Use Installation Instructions Approved for use in HVHZ: No FL11842 R3 II 2 PS EVALREPORT.Ddf Approved for use outside HVHZ: Yes Verified By: James L. Buckner, P.E.@ CBUCK, Inc P.E. Impact Resistant: N/A #31242 Design Pressure: N/A Created by Independent Third Party:Yes Other: Refer to Evaluation Report for Limitations and Evaluation Reports Conditions of Use. Refer to Manufacturer's Installation FL11842 R3 AE 2 PS EVALREPORT.Ddf Instructions as a supplemental guide for attachment. Created by Independent Third Party:Yes 11842.3 3-"Wind&Water Seal+" Self-Adhered Roof Underlayment attached to Plywood Deck Limits of Use Installation Instructions Approved for use in HVHZ: No FL11842 R3 II 3 WWS EVALREPORT.Ddf Approved for use outside HVHZ: Yes Verified By:James L. Buckner, P.E. @ CBUCK, Inc P.E. Impact Resistant: N/A #31242 Design Pressure: N/A Created by Independent Third Party: Yes Other: Refer to Evaluation Report for Limitations and Evaluation Reports Conditions of Use. Refer to Manufacturer's Installation FL11842 R3 AE 3 WWS EVALREPORT.Ddf Instructions as a supplemental guide for attachment. Created by Independent Third Party:Yes 11842.4 4-"STS" Self-Adhered Roof Underlayment attached to Plywood Deck Limits of Use Installation Instructions Approved for use in HVHZ: No FL11842 R3 II 4 STS EVALREPORT.Ddf Approved for use outside HVHZ: Yes Verified By:James L. Buckner, P.E. @ CBUCK, Inc P.E. Impact Resistant: N/A #31242 Design Pressure: N/A Created by Independent Third Party: Yes Other:Refer to Evaluation Report for Limitations and Evaluation Reports Conditions of Use. Refer to Manufacturer's Installation FL11842 R3 AE 4 STS EVALREPORT.Ddf Instructions as a supplemental guide for attachment. Created by Independent Third Party: Yes 11842.5 5-"Ultra HT Wind&Water Seal'""' Self-Adhered Roof Underlayment attached to Plywood Deck Limits of Use Installation Instructions Approved for use in HVHZ: No FL11842 R3 II 5 Ultra HT EVALREPORT.Ddf Approved for use outside HVHZ: Yes Verified By: James L. Buckner, P.E. P.E.#31242 Impact Resistant: N/A Created by Independent Third Party:Yes Design Pressure: N/A Evaluation Reports Other: Refer to Evaluation Report for Limitations and FL11842 R3 AE 5 UltraHT EVA LREPORT.Ddf Conditions of Use. Refer to Manufacturer's Installation Created by Independent Third Party: Yes Instructions as a supplemental guide for attachment. Back Next Contact Us::2601 Blair Stone Road Tallahassee FL 32399 Phone:850-487-1824 The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida ::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released In response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.-Pursuant to Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDqub%2fM2eroZG... 3/3/2017 .� ,, 4 / ,709 - C>,-2 (D" CBUCK E=nQ1nc-snr1nc;) Speclalfiy Structural Engineering nginering CBUCK,Inc.Certificate of Authorization#8064 Evaluation Report a "Ultra HT Wind & Water SealTM11 Roof Underlayment Manufacturer: MFM Building Products Corp. 525 Orange Street Coshocton, Ohio 43812 (740) 622-2645 for Florida Product Approval # FL 11842.5 R3 Florida Building Code 5th Edition (2014) Method: 1 - D Category: Roofing Sub - Category: Underlayment Product: "Ultra HT Wind &Water SeaIT""" Description: Self-Adhered Underlayment Prepared by: James L. Buckner, P.E., SECB Secure UaWe*Sea,to,Ekawrac Subm{tM Florida Professional Engineer#31242 \01%1111iflr,, Florida Evaluation ANE ID: 1916 ,� �5 ...•....SUC4;,''% Project Manager: Diana Galloway \ 4�ccNsfi �' Report No. 15-115-UHT-ER No 31242 * �_ (Revises 13-161-UHT-ER,FL16562.1) =-O LU Z Date: 4/02/15 p ,�•, STATE OF v •'•,�OR14P Contents: �`f� t /ONALe, '`�� Evaluation Report Pages 1-5 CBUCK,Inc. o+QrcSn�sgncdb:ramesGsvctmecv., 1399 N.Killian Drive,Suite 4,West Palm Beach,Florida 33403 2015.04.16 13:38:50-04'00' Phone:(561)491-9927 Fax:(561)491-9928 Website:www.cbuckinc.net FL#: FL 11842.5 R3 Date: 4/2/15 Report No.: 15-115-UHT-ER N BUCK Engineerl Page 2 of 5 Speclalty Structural Englneerinq CBUCK,Inc.Certificate of Authorization#8064 Manufacturer: MFM Building Products Corp. Product Name:. "Ultra HT Wind&Water Seal'""" Product Category: Roofing Product Sub-Category Underlayment Compliance Method: State Product Approval Rule 61G20-3.005(1) (d) Product Description: "Ultra HT Wind &Water Seal'""" is self-adhering membrane composed of a white, non-slip cross-laminated polymer film, laminated to a rubberized asphalt adhesive with a split release liner designed for use as a roof underlayment in high temperature conditions. Product Material/ Material Type: Styrene Butadiene Styrene(SBS) Standards: Material shall comply with ASTM D 1970 per Florida Building Code FBC 5th Edition (2014),Chapter 15. Product Dimension(s) Roll Size:36 in.x 67 ft. rolls Thickness:45 mils(nominal) Substrate(s): "Ultra HT Wind & Water SealTM" has been evaluated for application to the following substrates(Design of support is outside the scope of this evaluation): Plywood • Dens Deck Installation: General Installation Instructions: "Ultra HT Wind & Water SealT""' shall be installed in accordance with the attached installation method and in compliance with applicable code sections of the FBC 5th Edition (2014), subject to the Limitations and Conditions of Use listed in this Evaluation Report. Refer to installation details at the end of this report. Refer to manufacturer's installation instructions as a supplemental guide for attachment. - FL#: FL 11842.5 R3 Date: 4/2/15 Report No.: 15-115-UHT-ER CMUCK Engineering Page 3 of 5 Specialty Structural Engineerinq CBUCK,Inc.Certificate of Authorization#8064 Performance Standards: The product described herein has demonstrated compliance with: • ASTM D 1970-09 — Specification Self-adhering Polymer Modified Bituminous Sheet Materials Used as Steep Roof Underloyment for Ice Dam Protection Standards Equivalency: The ASTM D 1970-01 standard version used to test the product meets the prescribed standards in ASTM D 1970-09 standard version adopted by the Florida Building Code 5th Edition (2014)for use as evaluated in this report. Code Compliance: The products described herein have demonstrated compliance with ASTM D 1970-09 of Florida Building Code 2010. Evaluation Report Scope: This product has been evaluated in compliance with the building envelope requirements of the Florida Building Code, as related to the scope section to Florida Product Approval Rule 61G20-3.001. Product Limitations and • Deck shall be in compliance with applicable building code. Conditions of Use: • Minimum slope shall be 2:12 or greater. • Installation is limited to use with approved roof coverings that are mechanically fastened through the underlayment and is attached to the sheathing or rafters. • Not to be applied over active solvents or sealants, EPDM rubber or products containing silicone. • Do not expose product to direct sunlight for more than 60 days. General Limitations and • Scope of"Limitations and Conditions of Use"for this evaluation: Conditions of Use: This evaluation report for "Optional Statewide Approval" contains technical documentation, specifications and installation method(s) which include "Limitations and Conditions of Use" throughout the report in accordance with Rule 61G20-3.005. Per Rule 61G20-3.004, the Florida Building Commission is the authority to approve products under "Optional Statewide Approval". • Option for application outside "Limitations and Conditions of Use" Rule 61G20-3.005(1)(e) allows engineering analysis for "project specific approval by the local authorities having jurisdiction in accordance with the alternate methods and materials authorized in the Code". Any modification of the product as evaluated in this report and approved by the Florida Building Commission is outside the scope of this evaluation and will be the responsibility of others. • Fire Classification is outside the scope of Rule 61G20-3, and is therefore not included in this evaluation. • This evaluation report does not evaluate the use of this product for use in the High Velocity Hurricane Zone code section. (Dade & Broward Counties) FL#: FL 11842.5 R3 Date: 4/2/15 Cj Report No.: 15-115-UHT-ER N SUCK Engineerin Page 4 of 5 Specialftj Structural Engineering CBUCK,Inc.Certificate of Authorization#8064 Quality Assurance: The manufacturer has demonstrated compliance of roof panel products in accordance with the Florida Building Code and Rule 61G20-3.0005 (3) for manufacturing under a quality assurance program audited by an approved quality assurance entity through Keystone Certifications, Inc. (FBC Organization ID#QUA 1824). Referenced Data: 1. ASTM D 1970-01 Test By PRI Construction Materials Technologies, Inc. (FBC Organization ID#TST 1556) Report No. MFM-039-02-01, Date: 8/15/13 2. Equivalency of Test Standard Certification By James L. Buckner, P.E. @ CBUCK Engineering (FBC Organization#ANE 1916) 3. Quality Assurance Keystone Certifications, Inc. (FBC Organization ID#QUA 1824) MFM Building Products Corp. Licensee#335 4. Certification of Independence By James L. Buckner, P.E. @ CBUCK Engineering (FBC Organization#ANE 1916) FL#: FL 11842.5 R3 Date: 4/2/15 OL Report No.: 15-115-UHT-ER N ZBOUCK EncDIneering Page 5 of 5 SpPclalhj Structural EnglnLPPrinca CBUCK,Inc.Certificate of Authorization#8064 INSTALLATION METHOD MFM Building Products Corp. Ultra HT Wind & Water Seal Self-Adhered Roofing Underlayment General Installation Instructions: • Product to be applied directly to a clean dry surface. • Prime any weathered surfaces. Dens Deck must be primed with asphalt base primer. • Starting at the low point of the deck, peel back 12"of the release liner, align the membrane and press into place onto roof deck. • Adhesive is pressure-activated, so press firmly into place using uniform pressure with a 2-3" heavy steel or rubber roller to seams and overlap. • Overlap end laps a minimum of 6".Side laps must be a minimum of 3". • Store product in the carton in a dry place until ready to use. Keep product out of direct sunlight. • Apply membrane only in fair weather when the air, surface and membrane are at a minimum temperature of: 50° F • Not to be applied over active solvents or sealants, EPDM rubber or products containing silicone. • Do not expose product to direct sunlight for more than 60 days. Refer to the manufacturer's installation instructions as a supplemental guide for attachment. Product Illustrations +;U .TRA HT ♦ WIND&WATER SEAT! �q • EBUCK EnginsprInQ Specialty Structural EnglnP�ing CBUCK,Inc.Certificate of Authorization#8064 Certificate of Independence for Evaluation for # FL 11842 R3 MFM Building Products Corp. 525 Orange Street Coshocton, Ohio 43812 James L. Buckner, P.E. —CBUCK, Inc., Engineering—ANE 1916 1.) James L. Buckner, P.E. — CBUCK, Inc., Engineering does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products for which evaluations are issued. 2.) James L. Buckner, P.E. — CBUCK, Inc., Engineering is not owned, operated, or controlled by any company manufacturing or distributing products it evaluates. 3.) James L. Buckner, P.E. — CBUCK, Inc., Engineering does not have, nor will acquire, a financial interest in any company manufacturing or distributing products for which reports are being issued. 4.)James L. Buckner, P.E. —CBUCK, Inc., Engineering does not have, nor or will it acquire, a financial interest in any entity involved in the approval process of Secure Etectreidc SM to Ekcawnc subenft"I the product. \,t+11111ttr, *' No 31242 © 14, �`•, STATE OF i� s, ..... f`'i�1irNpttl1``` UigrmuV Signed 7Y tames L Buckner,P.E. 2015.04.16 13:38:50-04'00' 1399 N.Killian Drive,Suite 4,West Palm Beach,Florida 33403 Pagel of 1 Phone:(561)491-9927 Fax:(561)491-9928 Email:cbuck@cbuckinc.net • • T A , � r ` SpeClalfiy Structural Engineering CBUCK,Inc.Certificate of Authorization#8064 Equivalence of Product Standards for FL 11842 R3 RE: Test Standard Equivalency Statement Based on my evaluation of the standards relative to the evaluation reports in the above referenced Florida Product Approval: • The ASTM D 1970-01 standard version used to test the evaluated product assembly is equivalent to ASTM D 1970-09 standard version adopted by the Florida Building Code 5th Edition (2014). Secure Dewar&Seal for tlKuonic Submitbl '`4`tit4l4t1E1111��! .` E5 aCjf Ali /}/ 4`CEN$ '. FQ�f *' No 31242 rkA STATE OF r fS 0NAIe\;,` Digitally S%ncd by,lames l.Buskncr.SIX- Age 14ot 1 1399 N.Killian Drive,Suite 4,West Palm Beach,Florida 33403 Phone:(561)491-9927 Fax:(561)491-9928 Email:cbuck@cbuckinc.net