Loading...
HomeMy WebLinkAboutProduct Approval (2) i Florida Building Code Online Page 1 of 3 RAW -^-'r-s �r^ 'r"� ,�'� 'kv-r z aYA 1 �f s, .9+ �v�,nq e d �� �,�.,�a llkw �'�� � �fr.r:v � R � � #�� ps y, t� �� ;,dam• ��, ?K �,_.... Co- ?z �iF��` ^z� -� � �' r�$ � b til^' �s ,moi � �R• � � s:.:- BCIS Home {• Log In i User Registration Ho[Topia Submit Surcharge Stats&Facts Publications FBC Staff BCIS Site Map Links j Search Product Approval USER:Public User arorlixt Approval Menu>Product or Aoolication Search>Application I,ist>Application Detail FL# ;y FL24 �v awe a Application Type ReGislon Code Version Application Status Approved *Approved by DBPR.Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary. Comments Archived Product Manufacturer " PGT>dIndiistries Address/Phone/Email '' 107gy Drive North Venice,FL 34275 (941)486-0100 Ext 22318 druark@pgtindustries.com Authorized Signature ]ens Rosowski jrosowski@pgtindustries.com Technical Representative ]ens Rosowski Address/Phone/Email 1070 Technology Drive Nokomis,FL 34275 (941)486-0100 Ext 21140 Jrosowski@pgtindustries.com Quality Assurance Representative Address/Phone/Email rrr--- CategoryWmdows p Subcategory onzontal Shde[',.- LF 'rf Compliance Method Certification Mark or Listing Certification Agency Miami-Dade BCCO-CER Validated By Miami-Dade BCCO-VAL Referenced Standard and Year(of Standard) Standard- Year TAS 201,202,203 1994 Equivalence.of Product Standards Certified By Product Approval Method Method 1 Option A Date Submitted 09/07/2016 Date Validated 10/17/2016 Date Pending FBC Approval Date Approved 10/17/2016 http://www.floridabuilding.org/pr/pr_app_dti.aspx?param=wGEVXQwtDquUsDrhuM3 DG... 2/7/2017 Florida Building Code Onliner Page 2 of 3 Summary of Products FL# IlModel,Number or Name Description 242.1 JHR-210(Non-Impact). Aluminum Horizontal Roller Window Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL242 R21 C CAC 16-0629.02.odf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant:No 04/05/2022 Design Pressure:N/A Installation Instructions Other:Please see.the Miami-Dade County Notice of Acceptance(NOA) F1.242 R21 I1 16-0629.0 for product performance information,anchorage details,and anchor Verified By:Miami-Dade BCCO-CER type,size,and spacing information. Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 242.2 JHR-510(Impact) WinGuard Vinyl Horizontal Roller Window Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL242 R21. C CAC 15-0612.14.rdf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date I Impact Resistant:Yes 02/17/2021 1 I Design Pressure:N/A Installation Instructions Other:Please see the Miami-Dade County Notice of Acceptance(NOA) FL242 1321 I! 15-0612.14.udf for product performance information,anchorage details,and anchor Verified By:Miami-Dade BCCO-CER type,size,and spacing information. Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 242.3 HR-610(Non-Impact) WinGuard Aluminum Horizontal Roller Window Limits of Use_ Certification Agency Certificate - Approved for use in HVHZ:Yes FL242.R21 C CAC 16-G71 4.14.pdf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date i Impact Resistant:No 07/27/2021 Design Pressure:N/A Installation Instructions Other:Please see the Miami-Dade County Notice of Acceptance(NOA) FL242 R21 I 16-0714.14.rdf for product performance information,anchorage details,and anchor Verified By:Miami-Dade BCCO-CER type,size,and spacing information. Created.by Independent Third Party: Evaluation Reports Created by Independent Third Party: 242.4 1 IHR:-71Q;.(Impact) WinGuard Aluminum Horizontal Roller Window Limits of Use Certification Agency Certificate 1 Approved for use in HVHZ:Yes FL242 1'21. C CAC 16-07144.13.rdf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant:Yes 12/21/202- Design Pressure:N/A rnstallationInstrucdons Other:'Please see the Miami-Dade County Notice of Acceptance(NOA) FL242i R2Ltt�-16-07-14A1.udf k for product performance information,anchorage details,and anchor Verified By:Miami-Dade BCCO-CER (type,size,and spacing information. Created by Independent Third Party: 31 Evaluation Reports Created by Independent Third Party: i 242.5 HR-810(Large Missile Impact) Multi-Story Aluminum Horizontal Roller Window 3331 Limits of Use Certification Agency Certificate I Approved for use in HVHZ:Yes FL242 R21 C CAC 16-0714.10.odf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant:Yes 11/01/2017 Design Pressure:N/A Installation Instructions I Other:Please see the Miami-Dade County Notice of Acceptance(NOA) FL242 R21 II 16-0714.10.rdf {� 4 for product performance information,anchorage details,and anchor Verified By:Miami-Dade BCCO-CER type,size,and spacing information. Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 4 242.6 JiHR-BSO(Small Missile Impact) Multi-Story Aluminum Horizontal Roller Window Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL242 R21 C CAC 16-0714.15.0f Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant:Yes 11/01/2017 Design Pressure:N/A Installation Instructions Other:Please see the Miami-Dade County Notice of Acceptance(NOA) FL242 R21 Ii 16-0714.15.rdf , for product performance information,anchorage details,and anchor Verified By:Miami-Dade BCCO-CER type,size,and spacing information. Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: ' 242.7 HR-2710M(Impact) 2LT HR-2710M PVC Horizontal Rolling Window i Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL242 R21 C CAC 15-0528.23 M.rdf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant:Yes 12/23/2020 Design Pressure:N/A Installation Instructions Other:Please see the Miami-Dade County Notice of Acceptance(NOA) FL242 R21 I: 15-0528.23 M.rdf for product performance information,anchorage details,and anchor Verified By:Miami-Dade BCCO-CER type,size,and spacing Information.(2-lite XX only) Created by Independent Third Party: Evaluation Reports }i Created by Independent Third Party: 1242.8 HR-2710MI(Impact) 2/3 LT HR2710MI PVC HORIZONTAL ROLLER LMI 1€Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL242 R21 C CAC 13-1125.03 MI.rdf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant:Yes 12/23/2020 Design Pressure:N/A Installation Instructions Other:Please see the Miami-Dade County Notice of Acceptance(NOA) FL242 R21 II 13-11 25.03 MI.odf for product performance information,anchorage details,and anchor Verified By:Miami-Dade BCCO-CER type,size,and spacing information.(2-lite XX&3-lite XOX) Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 1242.9 HR-5410(Non-Impact) Vinyl Horizontal Roller Window Limits of Use Certification Agency Certificate Approved for use in HVHZ;Yes FL242 R21 C CAC 16-0714.18.odf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant:No 09/24/2020 http://www.floridabuilding.org/pr/,D _app_dtl.aspx?param=wGEVXQwtDquUsDrhum3DG... 2/7/2017 Florida Building Code Online Page 3 of 3 ' Design Pressure:N/A Installation Instructions Other:Please see the Miami-Dade County Notice of Acceptance(NOA) FL242 R21 II 16-0714.18.0f for product performance information,anchorage details,and anchor Verified By:Miami-Dade BCCO-CER type,size,and spacing information. Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 242.10 HR-5510(Impact) Vinyl Horizontal Roller Window Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL242 R21 C CAC 16-0714.17.01' Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant:Yes 09/24/2020 Design Pressure:N/A Installation Instructions Other:Please see the Miami-Dade County Notice of Acceptance(NOA) FL242 R21 II 16-0714.17.ndf for product performance information,anchorage details,and anchor Verified By:Miami-Dade BCCO-CER type,size,and spacing information. Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 242.11 JSGD-770 Window(Impact) Aluminum Horizontal Roller Window Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL27_fi,71 C CAC IC,ZOtii,2;�;f19.odf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant:Yes 02/12/2020 Design Pressure:N/A Installation Instructions Other:Please see the Miami-Dade County Notice of Acceptance(NOA) FL242 Rel-11 16-0620.09—q-of for product performance information,anchorage details,and anchor Verified By:Miami-Dade BCCO-CER type,size,and spacing information. Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 242.12 SGD-2500 Window(Non-Impact) Aluminum Horizontal Roller Window Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL242 P21 C CAC 15-0,509.09 WDW.odf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant:No 05/22/2018 Design Pressure:N/A Installation Instructions Other:Please see the Miami-Dade County Notice of Acceptance(NOA) FL242 R21 IT 15-0609.09 WDW.pdf for product performance information,anchorage details,and anchor Verified By:Miami-Dade BCCO-CER type,size,and spacing Information. Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 242.13 SGD-5570 Window(Impact) Vinyl Horizontal Roller Window Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL242 R21 C CAC 16-0505.01.odf I Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant:Yes 08/04/2021 Design Pressure:N/A Installation Instructions Other:Please see the Miami-Dade County Notice of Acceptance(NOA) FL242 1221 ti 16-0505.0'..odf for product performance information,anchorage details,and anchor Verified By:Miami-Dade BCCO-CER type,size,and spacing information. Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: (..........__.__...__._.__.._.__..----------..._._..__......__.._....__...--`----.__....__._.-..__...._......_._....._..__......._.......'--------_...__--._.._.-------`-..__.._....._--- E1'.. ti .. Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824 The State of Florida is an AA/EEO employer.Coovriaht 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395."Pursuant to Section 455.275 (1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address If they have one.The emalls provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here. Product Approval Accepts: Credit Card Safe http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param--wGEVXQwtDquUsDrhuM3DG... 2/7/2017 MIAMI•DADE MIAMI-DADE COUNTY o PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) 11805 S W 26 Street,Room 208 BOARD AND CODE ADMINISTRATION DIVISION T(786)315-2590 F(786)315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.gov/economy PGT Industries,Inc. 1070 Technology Drive North Venice,FL 34275 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami-Dade County RER - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ). This NOA shall not be valid after the expiration date stated below. The Miami—Dade County Product Control Section (In Miami—Dade County)and/or the AHJ(in areas other than Miami—Dade County)reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner,the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami—Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code, including the High Velocity Hurricane Zone.- DESCRIPTION: Series_`R_710—"A`lu inum Horizontal Rolling Window-L.M.I. APPROVAL DOCUMENT: Drawing No. 4127-10, titled "Alum. Horizontal Roller Window, Impact", sheets 1 through 11 of 11, dated 02/28/06,with revision G dated 05/05/16,prepared by manufacturer, signed and sealed by Anthony Lynn Miller,P.E.,bearing the Miami-Dade County Product Control Revision stamp with the Notice of Acceptance number and expiration date by the Miami-Dade County Product Control Section. MISSILE IMPACT RATING%Large and Small Missile Impaet Resistant. LA 3ELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state, model/series, and following statement: "Miami-Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process.Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA#15-0519.09 and consists of this page 1 and evidence pages E-1,E-2 and E-3,as well as approval document mentioned above. The submitted documentation was reviewed by Manuel Perez,P.E. €t NOA No.16-0714.13 MIAMI•DAD!COUNTY ry i ra itra 1t on`Date:--Deccmber2.1 202 1) p Approval-Date:_September-01,2016 Page 1 PGT Industries,Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED A. DRAWINGS 1. Manufacturer's die drawings and sections. (Submitted under NOA's No. 07-0815.09 and 06-0405.06) 2. Drawing No. 4127-10,titled"Alum.Horizontal Roller Window,Impact", sheets 1 through 11 of 11, dated 02/28/06,with revision G dated 05105/16,prepared by manufacturer,signed and sealed by Anthony Lynn Miller,P.E. B. TESTS 1. Test reports on: 1)Uniform Static Air Pressure Test,Loading per FBC, TAS 202-94 2)Large Missile Impact Test per FBC, TAS 201-94 3) Cyclic Wind Pressure Loading per FBC,TAS 203-94 along with marked-up drawings and installation diagram of a PVC sliding-glass door, a PVC fixed window and an aluminum sliding glass door, using: Kodispace 4SG TPS spacer system,Duraseal® spacer system, Super Spacer®NXTTM spacer system and XL EdgeTM spacer system at insulated glass,prepared by Fenestration Testing Laboratory, Inc., Test Reports No. FTL-8717, FTL-8968 and FTL-8970, dated 11116/15, 06/07/16 and 06/02/16 respectively, all signed and sealed by Idalmis Ortega,P.E. 2. Test reports on: 1)Large Missile Impact Test per FBC, TAS 201-94 2)Cyclic Wind Pressure Loading per FBC, TAS 203-94 along with marked-up drawings and installation diagram of an XOX aluminum horizontal sliding window,prepared by Fenestration Testing Laboratory, Inc., Test Report No. FTL-5330, dated 07/18/07, signed and sealed by Carlos S.Rionda,P.E. (Submitted under NOA No. 07-0815.09) 3. Test reports on: 1)Air Infiltration Test,per FBC,TAS 202-94 2)Uniform Static Air Pressure Test, Loading per FBC TAS 202-94 3)Water Resistance Test,per FBC, TAS 202-94 ..4)Large Missile Impact Test per FBC,TAS 201-94 5) Cyclic Wind Pressure Loading per FBC,TAS 203-94 6)Forced Entry Test,per FBC 2411.3.2.1,TAS 202-94 along with marked-up,drawings and installation diagram of an XOX aluminum horizontal sliding window,prepared by Fenestration Testing Laboratory,Inc., Test Report No. FTL-4858, dated 03/08/06, signed and sealed by Edmundo Largaespada, P.E. (Submitted under NOA No.0 6-04 0 5.0 6) Manuel Per , E. Product Control E a ner NOA No.16-0714.13 Expiration Date: December 21,2021 Approval Date: September 01,2016 E-1 PGT Industries,Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED B. TESTS (CONTINUED) 4. Test reports on: 1)Air Infiltration Test,per FBC,TAS 202-94 2)Uniform Static Air Pressure Test,Loading per FBC TAS 202-94 3)Water Resistance Test,per FBC,TAS 202-94 ..4)Large Missile Impact Test per FBC,TAS 201-94 5) Cyclic Wind Pressure Loading per FBC,TAS 203-94 6)Forced Entry Test,per FBC 2411.3.2.1, TAS 202-94 along with marked-up drawings and installation diagram of an XOX aluminum horizontal sliding window,prepared by Fenestration Testing Laboratory, Inc.,Test Report No. FTL-4859,dated 03/08/06,signed and sealed by Edmundo Largaespada, P.E. (Submitted under NOA No. 06-0405.06) C. CALCULATIONS 1. Anchor verification calculations and structural analysis, complying with FBC-51h Edition(2014), dated 05/14/15,prepared by manufacturer, signed and sealed by Anthony Lynn Miller,P.E. (Submitted under previous NOA No. 15-0519.09) 2. Glazing complies with ASTM E1300-09 D. QUALITY ASSURANCE 1. Miami-Dade Department of Regulatory and Economic Resources (RER). E. MATERIAL CERTIFICATIONS 1. Notice of Acceptance No. 14-0423.17 issued to Eastman CbemicaI Company (MA) for their"Saflex Clear and Color Glass Interlayers"dated 06/19/14, expiring on 05/21/16. 2. Notice of Acceptance No. 14-0916.10 issued to Kuraray America,Inc. for their "Kuraray Butacite®PVB Glass Interlayer" dated 04/25/15, expiring on 12/11/16. Manuel Pe z,P. Product Control E amin r NOA No.16- .13 Expiration Date: December 21,2021 Approval Date: September 01,2016 E-2 PGT Industries,Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED F. STATEMENTS 1. Statement letter of conformance, complying with FSC-5" Edition (2014), dated May 16,2015,issued by manufacturer, signed and sealed by A.Lynn Miller,P.E. (Submitted under previous NOA No. 15-0519.09) 2. Statement letter of no financial interest, dated May 16, 2015, issued by manufacturer, signed and sealed by A.Lynn Miller,P.E. (Submitted under previous NOA No. 15-0519.09) 3. Laboratory compliance letter for Test Report No. FTL-5330, issued by Fenestration Testing Laboratory, Inc., dated 07/18/07, signed and sealed by Carlos S. Rionda, P.E. (Submitted under NOA No. 07-0815.09) 4. Laboratory compliance letter for Test Reports No. FTL-4858 and FTL-4859, issued by Fenestration Testing Laboratory, Inc., dated 03/08/06,. signed and sealed by Edmundo Largaespada, P.E. (Submitted under NOA No. 06-0405.06) 5. Proposal No. 16-0125 issued by the Product Control Section, dated March 09,2016, signed by Ishaq Chanda,P.E. G. OTHERS 1. Notice of Acceptance No. 15-0519.09,issued to PGT Industries for their Series "HR-710"Aluminum Horizontal Rolling Window- L.M.I., approved on 07/09/15 and expiring on 12/21/21. Manuel Perez Product Control Exa r NOA No.16-0714.13 Expiration Date: December 21,2021 Approval Date: September 01,2016 E-3 F GENERAL NOTES:IMPACT HORIZONTAL ROLLER FLANGED AND INTEGRAL FIN WINDOW STANDARDS USED: •2014 FLORIDA BUILDING CODE(FSC),5TH EDITION 1.GLAZING OPTIONS:(SEE DETAILS ON SHEET 2).FOR INSTALLATION ABOVE 30 FT,GLASS TYPES G THRU L MUST HAVE A TEMPERED GLASS CAP. •ASTM E1300-09 •ANSIIAF&PA NDS-2012 FOR WOOD CONSTRUCTION A.5/16"LAMI CONSISTING OF(2)LITES OF 118"ANNEALED GLASS WITH A.090""PVB"'INTERLAYER": •ALUMINUM DESIGN MANUAL,ADM-2010 •AISI-S 700-07152-2010 B.5/16"LAMI CONSISTING OF(1)LITE OF 1/8"ANNEALED GLASS AND(1)LITE OF 118"HEAT STRENGTHENED GLASS WITH A.090-"PVB"INTERLAYER. C.5/16"LAM]CONSISTING OF(2)LITES OF 1/8"HEAT STRENGTHENED GLASS WITH A.090-"PVB"INTERLAYER. D.7/16"LAMI CONSISTING OF(2)LITES OF 3/16"ANNEALED GLASS WITH A.090""PVB"INTERLAYER. E.7116"LAMI CONSISTING OF(1)LITE OF 3/16"ANNEALED GLASS AND(1)LITE OF 3/16"HEAT STRENGTHENED GLASS WITH A.090-"PVB"INTERLAYER. NOA DRAWING MAP F.7/16"LAMI CONSISTING OF(2)LITES OF 3/16"HEAT STRENGTHENED GLASS WITH A.090-"PVB"INTERLAYER. SHEET G.13/16"LAMI IG:(1)LITE OF 118'OR 3/16"ANNEALED(MIN.)GLASS,5/16"OR 318"AIR SPACE AND 5/16"LAMI GENERAL NOTES.............1 CONSISTING OF(2)LITES OF 1/8"ANNEALED GLASS WITH A.090""PVB"INTERLAYER. GLAZING DETAILS............2 DESIGN PRESSURES.......3 H.13116"LAMI IG:(1)LITE OF 1/8'OR 3/16"ANNEALED(MIN.)GLASS,5116"OR 3/8"AIR SPACE AND 5/16"LAMI CONSISTING OF(1)LITE OF 1/8"ANNEALED GLASS AND(1)LITE ELEVATIONS.....................4 OF 118"HEAT STRENGTHENED GLASS WITH A.090""PVB"INTERLAYER. VERT.SECTIONS.............5 HORIZ.SECTIONS............5 I.13/16"LAMI IG:(1)LITE OF 1/8"OR 3/16"ANNEALED(MIN.)GLASS,5116"OR 318"AIR SPACE AND 5/16"LAM] PARTS LIST.......................6 CONSISTING OF(2)LITES OF 1/8"HEAT STRENGTHENED GLASS WITH A.090""PVB"INTERLAYER. EXTRUSIONS....................7 CORNER DETAIL..............5 J.13116"LAMI IG:(1)LITE OF 118"OR 3/16"ANNEALED(MIN.)GLASS,3116"OR 1/4"AIR SPACE AND 7/16"LAMI ANCHORAGE....................8.11 CONSISTING OF(2)LITES OF 3/16"ANNEALED GLASS WITH A.090-"PVB"INTERLAYER. K.13116"LAMI IG:(1)LITE OF 118"OR 3/16"ANNEALED(MIN.)GLASS,3/16"OR 1/4"AIR SPACE AND 716"LAMI CONSISTING OF(1)LITE OF 3/16"ANNEALED GLASS AND(1)LITE OF 3/16"HEAT STRENGTHENED GLASS WITH A.090-"PVB"INTERLAYER. L.13/16"LAMI IG:(1)LITE OF 1/8"OR 3116"ANNEALED(MIN.)GLASS,3116"OR 1/4"AIR SPACE AND'7/16"LAMI CONSISTING OF(2)LITES OF 3116'HEAT STRENGTHENED GLASS WITH A.090-"PVB"INTERLAYER. 2.CONFIGURATIONS:OX,X0,XOX 3.DESIGN PRESSURES:(SEE TABLES,SHEET 3) A.NEGATIVE DESIGN LOADS BASED ON TESTED PRESSURE AND GLASS TABLES ASTM E 1300. B.POSITIVE DESIGN LOADS BASED ON WATER TEST PRESSURE AND GLASS TABLES ASTM E 13W. 4.ANCHORAGE:THE 331/3%STRESS INCREASE HAS NOT BEEN USED IN THE DESIGN OF THIS PRODUCT.SEE SHEETS 8 THROUGH 11 FOR ANCHORAGE DETAILS. 5.SHUTTERS ARE NOT REQUIRED. PRODUCT REVISED M complying with the Pb" Bu;]a.g code 6.FRAME AND PANEL CORNERS SEALED WITH NARROW JOINT SEALANT OR GASKET. A.cepraoce ND I�'�� � 2t • Es imtion 7.REFERENCES:TEST REPORTS FTLA858,FTL-4859 AND FTL-5330. ELCO TEXTRON NOA'S ny. ANSI/AF&PA NDS FOR WOOD CONSTRUCTION A1mm oaePnaun CwnM�ti� ALUMINUM DESIGN MANUAL 8.THIS PRODUCT HAS BEEN DESIGNED&TESTED TO COMPLY WITH THE REQUIREMENTS OF THE FLORIDA BUILDING CODE, INCLUDING THE HIGH VELOCITY HURRICANE ZONE(HVHZ). 9.FOR INSTALLATION IN THE HVHZ ABOVE 30 FT,GLASS TYPES G-L SHALL HAVE A TEMPERED I.G.GLASS CAP.BOTH THE DP AND ANCHOR QUANTITY REMAIN UNCHANGED. "PVB"=.090"BUTACITEO PVB INTERLAYER BY KURARAY AMERICA,INC. JR OSM5116 G ADDED SPACERS TO SHEET 2. GENERAL NOTES ,•'••• r• e.wtma 1070 TECHNOLOGY DRIVE P.O.BOX 1529 ."•,;� •.`r C`'1'i"' ..•, N.VENICE,FL 34275 lei ~,'.'i.; ,�, •: R"s4 . oero n" c �� ALUM.HORIZONTAL ROLLER WINDOW,IMPACT --sr. NOKOMIS,FL 34274 Vhibly Better 'mac • wr. A. NNAI P.E. 5 F.K �128/OB JJ. 3/2306 HR7f0 -NTS 1 11 4127-10 G P.EH 58705 21TGLASS 21 i _. 50 Part# Description Material 75 Kommerling 4SG TPS Spacer System 1/2"NOM. See this M. 55 76 Quanex Super Spacer nXT with Hot Melt Butyl 53ITE GLASS BITE 77 Quanex Duraseal Spacer Sheet for Materials 78 Cardinal XL Edge Spacer 5162 51 63,64,65 REFERENCE TEST REPORTS:FTL-8717,8968&8970 ALED OR HEAT STRENGTHENED GLASS 3/16'ANNEALED OR HEAT STRENGTHENED GLASS INTERLAYER 090 PVB INTERLAYERALED OR HEAT STRENGTHENED GLASS 3f18'ANNEALED OR HEAT STRENGTHENED GLASS 7116'LAMINATED 5� 116"'I:AMINATED.GLASS 7/16"LAMINATED GLASS FOR INSTALLATION IN THE HVHZ ABOVE 30 F'r,GLASS TYPES G-L SHALL HAVE A TEMPERED I.G.GLASS CAP. j EXTERIOR INTERIOR[7I"> " PVB„= BOTH THE DP AND ANCHOR (ALL SECTIONS) KURARAY BUTACITE QUANTITY TO REMAIN PVBINTERLAYER UNCHANGED. 3 or 21 50 2ML SAFLEX PVB INTERLAYER BY 's EASTMAN CHEMICAL COMPANY ? 75-78 1/2"NOM.59 GLASS BITE 52 66,67,68,69,70,71 ,77118'ANNEALED OR HEAT STRENGTHENED GLASS HEAT STRENGTHENED GLASS .090 PVB INTERLAYER .090 PVB INTERLAYER 118'ANNEALED OR HEAT STRENGTHENED GLASS 3/16'ANNEALED OR HEAT STRENGTHENED GLASS 5116'LAMMATED 7116'LAMINATED 1 5116°OR 3/8'AIR SPACE 3/16'OR 714'AIR SPACE 1 116'OR 3/16'ANNEALED ORTEMPERED GLASS 118°or3/16'ANNEALED OR TEMPERED GLASS 13116'NOM. 13116"NOM. 13116"LAMI IG GLASS W/5/16"LAMI 13/16"LAM/IG GLASS W/7/16"LAMI S ALUMINUM SILICONE NOT-MELT BUTYL REINFORCEMENT POLYISO- DESICCANT FILL AREA PRODUCT REVISED STRUCTURAL BUTYLENE cmplyla9 with the Florida SILICONE SEAL 5/t6"NOM. pu{idalg Cie 5116"NOM. STRUCTURAL 1/4"NOM. FDAM 3/16"NOM. SILICONE SEAL Accepinaw No��O'G f , POLYISOBUTYLEN BUTYL& e 'mnnn Date ' � j WITH DESICCANT ROLL-FORMED ! WITH DESICCANT DESICCANT FOAM STAINLESS STEEL EXT.GLASS EXT.GLASS— EXT,GLASS tvlienil ed:Product oft J e EXT,GLASS .,,.'.:l 1'.. INT.GLASS INT.GLASS INT,GLASS INT.GLASS KODISPACE SUPER DURASEALO 7a XL EDGET"' 7s 4SG TPS 76 SPACER@NXTT'" SPACER SPACER _ � I Rr 05415718 M O GLAZING DETAILS ADDED SPACERS. ,...;•.0: Rs 1070 TECHNOLOGY DRIVE N.VENICE,FL 34275 '�• f pro: RoxYMc ALUM '``'�''•'' P.O.BOX 1529 .HORIZONTAL ROLLER WINDOW,IMPACT over0,-pro: CArdnCn.ptr< NOKOMIS.FL 34274 V!sllsly Better ✓awarAd.t m� d �� 8m- I,, t., I A.LYNNIMILLER,, P.E. FK 2/28/OB J.J. &2:1/08 HR710 FU/1 2 11 4127-1� (j P.E.N 58705 i' 'a"• TABLE 1. XOX(1/4,1/2,1/4)FLANGE OR INTEGRAL FIN WINDOWS(FLANGED SHOWN.FIN WINDOWS W/SAME DLO ARE 1"SMALLER) WINDOW GLASS WINDOW HEIGHT WIDTH TYPE 26" 36" 38 3/8" 48" 505/81, 54" 60" 63" 84" A,B,G,H +60.0 50.0 +60.0 -60.0 +60.0 -60.0 +60.0 -60.0 +60.0 50.0 +60.0 60.0 +60.0 60.0 +60.0 € 60.0 96" A,B,G,H +60.0 50.0 1 +60.0 € -60.0 +60.01 50.0 +60.0 -60.0 +60-01 -60.0 +60.0 -60.0 +58.8 -58.8 +56.2 -56.2 FOR INSTALLATION IN 106 318" A,B,G,H +60.0 -60.0 +60.0 ':. -60.0 +60.0 50.0 +60.0 50.0 +60.0 '•: -60.0 +60.0 -60.0 +55.2 -55.2 +52.3 -52.3 THE HVHZ ABOVE 30 108" A,B,G,H +60.0 -60.0 +60.0 11 -60.0 +60.0 -60.0 +60.0 -60.0 +60.0 ; -60.0 +60.0 -60.0 L SHALL HAVE+54.6 ; -54.6 +51.7 -51.7 GLASS EA G- L SA 111" A,B,G,H +60.0 -60.0 +60.0 1 -60.0 +60.0 -60.0 +60.0 -60.0 +60.0 50.0 +59.5 59.5 +53.6 1 -53.6 +50.9 -50.9 TEMPERED I.G.GLASS CAP.BOTH THE DP UP TO 111" C,I +60.0 i -60.0 AND ANCHOR NTITY UP TO 111" D,E,F, T+75.0 ; -75.0UNCHANG REMAIN J,K,LUNCHANGED. TABLE 2. XOX(1/3,1/3,1/3)FLANGE OR INTEGRAL FIN WINDOWS(FLANGED SHOWN.FIN WINDOWS W/SAME DLO ARE 1"SMALLER) WINDOW GLASS WINDOW HEIGHT WIDTH TYPE ALL HEIGHTS UP TO 63" TO 86 7/16" A'B'C'G,H,I +60.0 i -60.0 D,E,F, TO 86 7/16" J,K,L +75.0 -75.0 TABLE 3. OX AND XO FLANGE OR INTEGRAL FIN WINDOWS(FLANGED SHOWN.FIN WINDOWS W1 SAME DLO ARE 1"SMALLER) WINDOW GLASS WINDOW-HEIGHT----\ -WIDTH- TYPE 26" 36" 38 3/8" 48" 50 5/8" �, 54" 60" 63" 60" / A,B,G,H +75.0 75.0 +75.01 -75.0 +75.0 -75.0 +75.0 -75.0J +75.0 -75.0 1+75.0 -75.0 +75.0 -75.0 +75.0 -75.0 66" A,B,G,H +75.0 -75.0 +75.0 j -75.0 +75.0 -75.0 +75.0 -75.0 +75.0 ' -75.0 +75.0 -75.0 +74.2 1 -74.2 +70.2 -70.2 72" A,B,G,H +75.0 -75.0 +75.0 -75.0 +75-0 -75.0 +75.0 -75.0 +75.0 -75.0 +75.0 -75.0 +69.6 -69.6 +65.2 65.2 PRODUC'FaeViSeD ns e""tFlying with the Fimida 74" A,B,G,H +75.0 -75.0 +75.0 1 -75.0 +75.0 -75.0 +75.0 -75.0 +75.0 -75.0 +75.0 -75.0 +68.1 I -68.1 +63.8 ; -63.8 Elelldi"g Code �•ccplmce UP TO 74" C,D,E,F, +75.0 -75.0 R1 I,J,K,L ivlit""i daProd"a con d GLASS TYPES:TEST REPORT FTL-4858(XOX),FTL-4859(OX&XO)AND FTL-5330 A.5116"LAMI-(1/8"A,.090,1/8"A) G. 13/16"LAMI IG-1/8"OR 3/16"A(MIN.),5116"OR 3/8"AIR SPACE,5/16"LAMI-(1/8"A, .090,1/8"A) 1. B.5/16"LAMI-(118"A,.090,1/8"HS) H. 13116"LAMI IG-118"OR 3/16"A(MIN.),5/16"OR 3/8"AIR SPACE,5/16"LAMI-(1/8"A,.090,1/8"HS) C.5/16"LAMI-(1!8"HS,.090,1/8"HS) I. 13/16"LAMI IG-116"OR 3/16"A(MIN.),5/16"OR 3/8"AIR SPACE,5/16"LAMI-(1/8"HS,.090,1/8"HS) D.7/16"LAMI-(3/1fi"A,.090,3/16"A) J.13/16"LAMI IG-1/8"OR 3/16"A(MIN.),3/16"OR 1/4"SPACE,7/16"LAMI-(3/16"A, .090,3/16"A) E.7/16"LAMI-(3/16"A,.090,3/16"HS) K. 13/16"LAMI IG-1I8"OR 3116"A(MIN.),3/16"OR 1/4"SPACE,7/16"LAMI-(3/16"A,.090,3/16"HS) V. F.7116"LAMI-(3116"HS, .090,3116"HS) L.13/16"LAMI IG-1/8"OR 3/16"A(MIN.),3116"OR 1/4"SPACE,7/16"LAMI-(3/16"HS, .090,3116"HS) y Br 0- 1070 TECH NOLOGYDRNE DESIGN PRESSURES N.VENICE,FL 34275 P.O.BOX 1529 A- � ALUM.HORIZONTAL ROLLER WINDOW,IMPACT smaeaart art � ,� NOKOMIS,FL 34274 Yvtbly Better A.LYNN MILLER,P.E. to F�Qt22� p" _312=6=8 HR710 NTS 3 d 11 p�yy4127-10 G P.E.#5070.5 r: .v- 27 318" 27 27 MAX.DLO 54 5116"MAX.DLO FIXED MAX.DL DLO MAX.DLO VENT VENT FIXED D D B a B B X O x x 0 x _ — — — I ��-. 110"'MAX.WIDTH I.F.FRAME —moi Ir 65 7116"MAX.WIDTH I.F.FRAME � - 111"MAX.WIDTH FLANGE FRAME -i r-- 6 7/16"MAX.WIDTH FLANGE FRAME DETAIL B-XOX(1/4-1/2-1/4) DETAIL C-XOX(113-1/3-1/3) NOTE: 33 9116"MAX. 33 9116"MAX. 1.SEE SHEET 5 FOR VERTICAL AND HORIZONTAL SECTION DETAILS. DLO FIXED c DLO VENT r i SEALANT OR GASKET 63"MAX. AT HEAD AND SILL FLANGE A I A FRAME ALL 15 MAX.3/8" 56„ CONFIG. MMAX. PRODUCT REVISED DLO ALL —— 15 I.F.FRAME ns complying with the Flmida DLO ALL / I / VENTS — Ouildisg n N ` -D FIXED 62"MAX. — Acoep"-n No LITES I.F.FRAME i:-•pirali0n Date Q X ALL BYCONFIG. mm'DedeProdact d I 13 FLANGE FRAME C 73"MAX.WIDTH I.F.FRAME—�II VIEW D-D 74"MAX.WIDTH FLANGE FRAME —I ( FRAME CORNER CONSTRUCTION) - _- DETAILA-OXORXO n.neay �; pn,gy,r 1070TECHNOLOGY DRIVE ELEVATIONS N.VENICE,FL 34276 tms "•'t.`I`I}"'.` `` ALUM.HORIZONTAL ROLLER WINDOW,IMPACT P.O.BOX 1529 a.r s,r• — o..dcK M NOKOMIS,FL 34274 �/csrbly Bettcr A.LYNN MILLER,P.E. HR710 NTS 4 - 11 41"17-10 G P.E.458705 F: cw- . INTERIOR 37 32 35 22 39 1 22 0 9 16 2 EXTERIOR INTERIOR I 13 21 MAX.VENT DLO MAX.FIXED DLO MAX. T DLO MAX.WIDTH(FLANGE FRAME) EXTERIOR 19 SECTION B-B 17 (HORIZONTAL SECTION-XOX SHOWN WITH FLANGE FRAME) MAX. INTERIOR 35 32 37 HEIGHT 39 FLANGE FRAME MAX. VENT q 16 DLO MAX. FIXED DLO II 22 I� MAX.FIXED DLO MAX.VENT DLO 43 MAX.WIDTH(I.F.FRAME) 21 EXTERIOR SECTION A-A (HORIZONTAL SECTION-OX SHOWN WITH INTEGRAL FIN FRAME) 24 r 8 22 21 41 22 PRODUCT REVISED �s—plyiug with the Florida 2 0 Idle,Code W 12EXTERIOR INTERIOR � 7 no [t 12 21 Mu,:ni Jadc Ptodect Con 7 EXTERIOR INTERIOR 6 10 SECTION C-C 42 SILL HEAD (VERTICAL SECTION, FLANGE FRAME) (VERTICAL SECTION, I.F.FRAME) (VERTICAL SECTION,I.F. FRAME) wwmar : Rmlxbra r, 1070 TECHNOLOGY DRIVESECTIONS ` N.VENICE,FL 94275 ^0"' ',..1}'• rs, or w� sewcw�c �T ALUM.HORIZONTAL ROLLER WINDOW,IMPACT P.O.BOX 1529 sem, , aron. p,,,,tty a,,. A.LYNN MILLER,P.E. rn.Far NOKOMIS,FL34274 Visibly Better HR7f0 J.J. 3123106 Half 5 m 11 4127-1� G P.E.rt 59705 F.K. 1!28/06 - I11IDFDESCRIPTION PGI# TEEM DWGN REV DESCRIPTION MAT'L PGI# E 1 4102 A FLANGE FRAME HEAD 6063-T6 AL 612237 66 IGLASSI 13/16"LAMI IG1/8"A(MIN.),3/8"AIR SPACE 5/16"LAMI(1/8"A-0%PVB,1/8"A 2 4025 1 SASH STOP(STD.)(ANTI LIFT CLIP) 6063-TS AL 612244 67 1 113/16"LAM[IG1/8"A(MIN.),3/8"AIR SPACE 5/16"LAMI(1/8"A-090 PVB,1/8"HS 3 1#8 X 3/4 PH.PAN HEAD 7834AA 68 1 113/16"LAM[IG1/8"A(MIN.),3/8"AIR SPACE 5/16"LAMI(1/8"HS,.090 PVB,1/8"HS) 4 4053 ISASH STOP COVER(SASH STOP) 6063-T5 AL 69 1 113/16"LAMI 1&3116"A(MIN.),5/16"AIR SPACE 5/16"LAMI(I/8"A,.090PVB,1/8"A) 6 4136 FLANGEFRAMESIIJ 6063 T6 AL 64136 70 13/16"LAMI IG-3/16"A(MIN.).5116"AIR SPACE.5/16"LAMI(ll8"A,.090PVB,1/8"HS) 7 4137 ISILLADAPTOR 6063-T6 AL 64137 71 13/16"LAMI IG-3/16"A(MIN.),5/16"AIR SPACE 5/16"LAMI(118"HS,.090 PVB,1/8"HS) 8 4131 IROLLERTRACK 6063-T6 AL 64131 72 13/16"LAMI IG•1/8"A(MIN), AIR SPACE 7116"LAMI(3/16"A,.090 PVB,3/16"A) 10 71298 WEEP HOLE COVER POLYPROP. 71298 73 13/16"LAMI IG-1/8"A(MIN),1/4"AIR SPACE,7/16"LAMI(3/16"A,.090 PVB,3116"HS) 12 1 26 WEEP HVEOPEN CELLFOAM PAD 7P71298 74 13116"LAMI IG-1/8"A(MIN.),1/4"AIR SPACE,7/16"LAMI(3116"HS,.090PVB,3/16"HS) 75 13/16"LAMI IG-3116"A(MIN.),3/16"AIR SPACE,7/16"LAMI(3/16"A..090 PVB,3/16"A) 13 4002 A IFLANGE FRAME JAMB 6063-T6 AL 612225 76 13/16"LAMI IG-3/16"A(MIN.),3/16"AIR SPACE,7/16"LAMI(3/16"A,.090 PVB,3/16"HS) 14 4134 IGASKET FOR MAIN FRAME SILL JOINT 74134W/K 77 " 13/16"LAMI 16-3/16"A(MIN.),3/16"AIR SPACE 7/16"LAMI(3/16"HS,.090 PVB,3/16"HS) 15 1 1155 #8 X 1:000 QUAD PN.SMS 791PQA 90 1014 SCREENFRAME(HOR&VER.) 3105-1114 AL 16 1 4110 G I SCREEN ADAPTOR 6063-T5 AL 6411OG 91 1630 SCREEN CORNER KEY W/RINGS POLYPROP. 17 1 4054 B IEDaDmEETINGRAm 6063HD-T6 AL 64054A 92 1631 SCREEN CORNER KEY W/OUT RINGS POLYPROP. 19 4066W STP.,.187 X.230,FIN SEAL 64066G 93 1073 SCREEN SPRING ST.ST. 21 4105 SASH TOP&BOTTOM RAIL 6063-T5 AL 612240 94 1624 SCREEN SPLINE-.135 DIA.FOAM EM PVC 22 1683 W STP.,250 X.270 BACK,FIN SEAL 61683G 95 1635 SCREEN SPLINE-.135 DIA.HARD EM PVC 23 225-1 ROLLERHOUSING&GUIDE 42112HD 96 SCREEN CLOTH 24 226 BRASS ROLLER WHEELS BRASS 7BRWHL2 29 4128 HORIZONTAL ROLLER SASH TOP GUIDE POLYPROP. 44129N 32 4006 D SASH MEETINGRAIL 6063HS-T6 AL 64006 2.710 33 1235 W STP.,.170 X.270 BACK,FIN SEAL 67S 16G 35 1096 SWEEP LATCH' DICAST 71096 36 1016 #8 X.625 PH.FL.SMS 7858 37 4126 SASH SIDERAIL 6063-T5 AL 64126 2.624 38 1683 W STP.,.250 X.270 BACK,FIN SEAL 61683G 062 39 1 7070 BULB WEATHERSTRIP.187 X.275 67070K 40 LIFT RAIL COVER CAP 74078"C"L OR R 41 4139 I.F.FRAME HEAD 6063-T6 AL 64139 I.F.FRAME HEAD 42 4140 I.F.FRAME SILL 6063-T6 AL 64140 41 #4139,6063-T6 43 4141 I.F.FRAME JAMB 6063-T6 AL 64141 50 GLAZING SILICONE;DOW 899,995 OR UIVALENT PRODUCT REVISED 51 1224 VINYL GLAZING BEAD BULB(THICK) 6TP247W,K u ildhig ivg wi h the Flor da 52 1225 VINYL GLAZING BEAD BULB(THIN) o"a p ane 6TP248K 2.784 Acccptenro No44'53 4039 B GLAZINGBEAD-5/16" 6063-T5 AL 64039B pir®twn pat54 4044 B GLAZINGBEAD-5/16"W/GRILLKTr 6063-T5AL 644703 .062 "i3.152 55 4222 A GLAZINGBEAD-7/16" 6063-TS AL 64222 56 985 C GLAZINGBEAD-7/16 W/GRILL KIT 6063-T5 AL 6985 062 1.988 T 59 4067 GLAZINGBEAD-13/16 6063-T5 AL 64067 60 GLASS 5/16"LAMI(1/8"A,.090PVB,I/8"A) 43 LF.FRAME JAMB 61 5/16"LAMI(1/8"A_090 PVB,1/8"HS) #4141,6063-T6 62 " 5116"LAMI(1/8"HS,.090 PVB,1/8"HS) 63 7/16"LAMI(3/16"A_090 PVB,3116"A) 2.710 64 7/16'LAMI 3/16°A,.090PVB,3/16"HS) 42 I.F.FRAME SILL 65 7/16'LAMI(3/16"HS,.090 PVB,3/16"HS) #4140,6063-T6 1ra„aer• ai.: w...n� o.�• o.ro: 1070 TECHNOLOGY DRIVE PARTS LIST N.VENICE,FL 34276 TALUM.HORIZONTAL ROLLER WINDOW,IMPACT P.O.BOX 1529 ua.e pq,aow," part fro: N 1111-I-ER, a.o dB Ovr NOKOMIS,FL 34274 1,14ibly Better HR710 NTS B a 11 41"1]-10 G+ A.LYP P. 68705 P E F.K. 223106 J.J. 3/23/06 > .v 513{ .062 � 1.187 f—�— P443-� .738 3. 52 —T 1.. 13 .062 O SASH STOP COVER 1.273 � .062 3.090 4 #4053,6063-T5 jL 1.122 O FLANGE FRAME HEAD 2.784--1 FLANGE 1 O FLANGE FRAME SILL O FRAME SILL ADAPTER T #4102A,6063-T6 #4136,6063-T6 #4137,6063-T6 I 1.363 T6 � 062 061 1.17 7 .062 13 FLANGE FRAME JAMB #4002A,6063-T6 4901-1 "ll F l-403� O SASH STOP Og :HORIZ.ROLLER TRACK 17 FIXED MEETING RAIL #4025,6063-T5 #4131,6063-T6 #4054B,6063HD-T6 "349-4 2. 79 .062—CF F7 2.326 �9 .058 1.183 .062 I .678 1.291+I{r-1 ---( 1.081 � 1.096 —T O SED SASH TOP&BOTTOM RAIL 82 SASH MTG.RAIL 37 SASH SIDE RAIL 53 GLAZING BEAD,5/16" F2OniplyinSUCT ilhtht 21 as complying with the ClRida #4133,6063-T5 #4006D,6063HS-T6 #4126,6063-T5 #40396,6063-T5Building Code ,e�epta,�rrnlG-o � ''121 2r:imtiem Date_ .oso _1 ;.iiaati Product Controi� � .678 •678 .050678 .683 .050 1.096 4444SSSS LLLLLL������ I I I 1.096 1.1 1.115—t-+--+••I� —r-+--�'t-1.097 GLAZING BEAD,5/16" 55 GLAZING BEAD 7/16" 56 GLAZING BEAD,7/16" 59 GLAZING BEAD,13/16" #40448,6063-T5 #4222A,6063-T5 #985C;6053-T5 #4067,6063-T5 (USED W/GRILL KIT) (USED W/GRILL KIT) Zi,.�Sc'7G=' eY oerx y"mom 1070 TECHNOLOGY DRIVE TRUSI EX N.VENICE,FL 34276 T"� r�,f Imo+;•+r,•t^•.r,,'t.,.' Flo: BaNetaa' m ALUM.HORIZONTAL ROLLER WINDOW,IMPACT P.O.BOX 1529 er. ooa: txudoe t>om: NOKOMIS,FL 34274 VWbly Bette- "� A LYNN MILLER,RE F.1G 1l19/OS J.J. 3/1306 HR710 Half 7 a 11 4127-10 QP.Eq 58705 n I � ANCHOR QUANTITIES,XOX 114-112-114 WINDOWS TABLE 4 NOTES: GLASS TYPES A,B,C,G,H,I GLASS TYPES D,E,F,J,K.L 1. ANCHOR TYPES: ANCHOR TYPE 2,3,WOOD 2,CONC 1,CONC 2,3,WOOD 2,CONC 1.CONC 1-1/4"ELCO TAPCONS 2-1/4"ELCO SS4 CRETE-FLEX 3-#12 STEEL SCREWS(G5) &SUBSTRATE ZONES ZONES ZONES ZONES ZONES ZONES Im !m im ly im m 2.GLASS TYPES: 'm •m m '•m 'm m A.5/16"LAMI- 1/8"A,.090,1!8"A) FOR INSTALLATION IN THE HVHZ ABOVE 30 WINDOW SIZE HEAD&SILL! HEAD&SILL:g HEAD&SILL:g HEAD&SILL! HEAD&SILL M HEAD&SILL j W H :� !� B.5/16"LAM[-(1/8"A,.090,1/8"HS) FT,GLASS TYPES G-L SHALL HAVE A C.5116"LAMI-(118"HS,.090,1/8"HS) TEMPERED I.G.GLASS CAP.BOTH THE DP AND 53.125x 38.375 1+02+1+C2+112 1+C2+1+C2+1 i 2 1+C2+1+C2+1:2 1+C2+1+C2+11 2 1+C2+1+C2+1:2 1+C2+1+C2+1 i 2 D.7/16"LAMI-(3116'A,.090,3/16"A) ANCHOR QUANTITY REMAIN UNCHANGED. 48.000 1+C2+1+C2+1i 3 1+C2+1+C2+1:3 1+C2+1+C2+1:3 1+C2+1+C2+1 3 1+C2+1+C2+1 3 1+C2+1+C2+1 3 E.7116"LAM]-(3/16"A,.090,3116"HS) 50.625 1+C2+1+C2+ii 3 1+C2+1+C2+1'•.3 1+C2+1+C2+1:3 1+C2+1+C2+1!3 1+C2+1+C2+1:3 1+C2+1+C2+1!3 F.7/16"LAMI-(3/16"HS,.090,3/16"HS) G.13/16"LAMI IG-1/8"OR 3/16-A(MIN.),5116"OR 318"SPACE,5116"LAMI-(1/8-A,.090,1/8"A) 54.000 1+C2+1+C2+11 3 1+C2+1+C2+1 i 3 1+C2+1+C2+1:3 1+C2+1+C2+1 3 1+C2+1+02+1'3 t+C2+1+C2+1 li 3 H.13/16"LAMI IG-1/8"OR 3116"A(MIN.),5116"OR 3/8"SPACE,5116"LAMI-(118"A,.090,1/8"HS) 60.000 1+C2+1+C2+1 3 1+C2+1+C2+1:3 1+C2+1+C2+1:3 1+C2+1+C2+1'•3 1+C2+1+C2+1:3 t+C2+1+C2+1 3 I. 13/76"LAMI IG-118"OR 3116"A(MIN.),5/16"OR 3/8"SPACE,5/16"LAMI-(1/8"HS,.090,1/8"HS) J.13/16"LAMI IG-118"OR 3116"A(MIN.),3/16"OR 1/4"SPACE,7/16"LAM]-(3/16"A,.090,3116"A) 63.000 1+C2+1+C2+11 3 1+C2+1+C2+1:3 1 1+C2+1+C2+1 1 3 1+C2+1+C2+1 i 3 1+C2+1+C2+1!3 1+C3+1+C3+1'3 K.13/16"LAM[IG-1/8"OR 3/16"A(MIN.),3116"OR 114"SPACE,7116"LAMI-(3116"&.090,3116"HS) 60.000 x 38.375 1+C2+1+C2+112 1+C2+1+C2+1 2 1+C2+1+C2+1 i 2 1+C2+1+C2+1:2 1+C2+1+C2+1i 2 1+C2+2+C2+11 2 L. 13/16"LAMI IG-1/8"OR 3/16"A(MIN.),3116"OR 1/4"SPACE,7/16"LAMI-(3/16"HS,.090,3/16"HS) 48.000 1+C2+1+C2+113 1+C2+1+C2+113 1+C2+1+C2+1 j 3 1+C2+1+C2+1:3 1+C2+1+C2+1i 3 1+C2+2+C2+1 i 3 3.WINDOW ANCHOR QUANTITIES ARE PER ADJACENT TABLE AND BASED ON THE FOLLOWING 50.625 1+02+1+C2+1i 3 1+C2+1+C2+1:3 1+C2+1+C2+1!3 t+C2+1+C2+1:3 1+C2+1+C2+113k+C2+2 C2+11 3 DIMENSIONS. FOR WINDOW SIZES NOT SHOWN,GO TO NEXT LARGER WINDOW IN TABLE. 54.000 1+C2+1+C2+113 1+C2+1+C2+1e 3 1+C2+1+C2+1:3 1+C2+1+C2+1i 3 1+C2+1+C2+1:3C2+1!3 HEAD&SILL: 10 1/2"MAX.ON EACH SIDE OF MEETING RAIL CENTERLINE. 60.000 1+C2+1+C2+1:3 1+C2+1+C2+1:3 1+C2+1+C2+1:3 1+C2+1+C2+1'1 3 1+C2+1+C2+1:3q+i i 3 25 3/4"MAX.FROM CORNERS. JAMBS: 9"MAX.FROM CORNERS AND 22 1/2"MAX.O.C. 63.000 1+C2+1+C2+1:3 1+C2+1+02+11 3 1+C2+1+C2+1i 3 1+C2+1+C2+ti 3 1+C2+1+C2+1l 3C3+1j 3 TABLE KEY: 74.000x 38.375 1+C2+2+C2+1 2 1+C2+1+C2+ti2 1+C2+2+C2+1:2 1+C2+2+C2+1j2 1+C2+2+C2+11 2 C2+1 2 X 0 X 48.000 1+C2+2+C2+ti 3 1+C2+1+C2+1:3 1+C2+2+C2+1:3 1+C2+2+C2+1:3 1+C2+2+C2+1 3C2+1;3 1+C3+q+C3+13 ANCHOR QUANTITY PER JAMB 50.625 1+C2+2+C2+1 3 1+C2+1+C2+1 3 1+C2+2+C2+1:3 1+C2+2+C2+1:3 1+C2+2+C2+1:3I :3 HEAD AND SILL ANCHOR QUANTITY. 54.000 1+C2+2+C2+1i3 1+C2+1+C2+1i 3 1+C2+2+C2+1;3 1+02+2+C2+1?3 1+C2+2+C2+1:3C3+11 3 A CLUSTER OF(3)ANCHORS CENTERED AT EACH MEETING RAIL PLUS(1) 60.000 1+C2+2+C2+1:3 1+C2+1+C2+1:3 1+C2+2+C2+1 i 3 1+C2+2+C2+1 31+C2+2+C2+1i 3 1+C3+2+q+t i 31 ANCHOR AT EACH OPERABLE VENT 63.000 1+C2+2+C2+1!3 1+C2+1+C2+1:3 1+C3+2+03+1 3 1+C3+2+C3+1!3 1+C2+2+C2+1:3 1+C3+2+q+1!31 PLUS(4)ANCHORS AT FIXED SECTION. 84,000x 38.375 1+C2+2+02+1I 2 1+C2+2+02+11 2 1+C2+2+C2+11 2 1+C2+2+C2+1?2 1+C2+2+C2+112 1+C2+3+C2+1:2 (12)ANCHORS TOTAL AT HEAD AND SILL. 48.000 1+C2+2+02+1:3 1+C2+2+C2+113 1+C2+2+C2+1i 3 1+C2+2+C2+1!3 1+C2+2+C2+11 3 1+03+3+C3+1:31 (3"MIN.O.C.ANCHOR SPACING) 50.625 1+C2+2+C2+1i 3 1+C2+2+02+1 3 1+C2+2+C2+1i 3 1+C2+2+C2+1:3 1+C2+2+C2+1`:•3 1+C3+3+C3+113 64.000 1+C2+2+C2+1:3 1+C2+2+C2+1 i 3 1+C2+2+C2+1 3 1+C2+2+C2+1:3 1+C2+2+C2+1:3 1+C4+3+61+1!3 25 3/4"max. MIN. 60.000 1+C2+2+C2+113 1+C2+2+C2+1:3 1+p .. . +2+C3+1:3 1+C3+2+C3+1 3 1+C2+2+C2+1:3 1+C4+3+C4+1i 3 L 63.000 1+C2+2+C2+11.3 1+C2+2+02+1':.3 1+C3+2+C3+1 3 1+C3+2+C3+1 i 3 1+C2+2+C2+1:3 1+C4+3+C4+1 3 106.375x 38.375 1+C2+2+C2+11 2 1+C2+2+C2+1:2 1+02+3+C2+1'2 1+C2+3+C2+1i 2 1+C2+3+C2+1:2 1+C2+4+C2+1'2 PRODUCTREVISED i J us complying with 8rc Flo de i 8uildiag Cock 48.000 1+C2+3+C2+1t1 3 1+C2+2+C2+113 1+p+3+C3+1:3 1+C3+3+03+11:131+C2+3+C2+1!3 1+C3+q+q+11 3 MTG.RAIL,TYP. Acce��^�I(o-O 1Q..,13 2) 50.625 1+C2+3+C2+ti 3 1+cz+2+C2+t:3 1+p+3+C3+1i 3 1+C3+3+C3+1:3 1+C3+3+C3+1�3 1+C3+q+p+1;3 EXAMPLE CLUSTER W/QTY.OF(3)ANCHORS 1 54.000 1+p+3+C3+11!3 1+C2i2+02+1:3 1+q+3+C3+11 3 1+C3+3+C3+1 3 1+C3+3+03+1i 3 1+C4+4+CA+1'3 (SHOWN IN TABLE KEY ABOVE) 13Y (/ Rfiami 'mdact C aI 60.000 1+C3+3+C3+113 1+C2+2+C2+1:3 1+C4+3+C4+11 3 1+04+3+C4+1i 4 1+C3+3+C3+113 1+C4+4+C4+13 63.000 1+p+3+C3+11 3 1+C2+2+C2+1i:3 1+C4+3+C4+1 y 3 1+C4+3+C4+1 E 4 1+C4+3+C4+1:3 1+C5+4+C5+1 3 25 314"MAX. 111.000x 38.375 14C2+3+02+112 1+C2+2+C2+1i 2 1+C2+3+C2+111 2 1+C2+3+C2+1,3 1+C2+3+C2+1;2 1+C2+4+C2+1I►-3/MIN.P 48.000 1+02+3+C2+1:3 1+C2+2+02+1;3 1+C3+3+C3+11:3 1+C3+3+C3+113 1+C2+3+C2+1:3 1+C3+4+C3+1!39" REF. X 0 X 50.625 1+C2+3+C2+1:3 1+C2+2+02+1:3 t+C3+3+C3+.1:3 1+C3+3+C3+1�3 1+C3+3+C3+1:3 1+C3+4+C3+1 i 3LL j 1+C2+2+C2+1p :3 1+ +3+C3+1i 3 1+C3+3+C3+1:3 1+C3+3+C3+1s 3 1+C4+4+C4+1�3 64.000 1+C3+3+C3+11 3 i 60.000 1+C3+3+C3+113 1+C2+2+02+11 3 1+C4+3+C4+11 3 1+C4+3+C4+1:4 1+C3+3+C301 3 1+C4+4+C4+1 3 MTG.RAIL,TYP. - 63.000 1+p+3+C3+11 3 1+C2+z+cz+1 3 1+C4+3+C4+1 3 1+C4+3+C4+1:4 1+C4+3+C4+11 3 1+C5+4+C5+1,4 EXAMPLE CLUSTER W/QTY.OF(4)ANCHORS 14. R.naer. 1070 TECHNOLOGY ANCHORAGE SPACING,XOX 1/4-1/2-1/4 N.VENICE,FL P.O.80%75229 ALUM.HORIZONTAL ROLLER WINDOW,IMPACT Rana amr: Pnfabn• 9 ;•::,,,. .. NOKOMIS,FL 34274 Viobly&at a �1r 6 �lYNu A.LYNN MILLER P.E. F.K. 1/ZBIDG J.J. 3234]6 HR710 NTS 8 a, 11 4127-10 G P,E.058705 l __ I p, ,P NOTES: t3/4"MIN.E.D.TYP. 2,WOOD BUCK, 1.FOR CONCRETE APPLICATIONS IN MIAMI-DADE COUNTY,USE ONLY MIAMI-DADE COUNTY APPROVED 1/4"ELCO MIN.3.4 KSI 1"MIN.EDGE NOTE 3 1 3/8" TAPCONS EMBEDED 1 3/8"MIN.OR 1/4"SS4 CRETE-FLEX EMBEDED 1 3/4"MIN.. MINIMUM DISTANCE FROM CONCRETEMIN. ANCHOR TO CONCRETE EDGE IS 13/4". FLATHEAD ANCHORS MUST BE#12 TRIMFIT HEAD. NOTE 1 1x WOOD ' <• I 2.FOR WOOD APPLICATIONS IN MIAMI-DADE COUNTY,USE#12 STEEL SCREWS(G5)OR 1/4"SS4 CRETE-FLEX WITH BUCK, #12 TRIMFIT HEAD. i NOTE 3 1 3.WOOD BUCKS DEPICTED IN THE SECTIONS ON THIS PAGE AS 1x ARE BUCKS WHOSE TOTAL THICKNESS IS LESS 114" j 1/4" THAN 1 1/2". 1x WOOD BUCKS ARE OPTIONAL IF UNIT CAN BE INSTALLED DIRECTLY TO SOLID CONCRETE OR MAX. MAX. CMU.WOOD BUCKS DEPICTED AS 2x ARE 1 1/2"THICK OR GREATER. INSTALLATION TO THE SUBSTRATE OF SHIM SHIM WOOD BUCKS TO BE ENGINEERED BY OTHERS OR AS APPROVED BY AUTHORITY HAVING JURISDICTION. CONCRETE WOOD ANCHOR, ANCHOR, 4.FOR ATTACHMENT TO ALUMINUM:THE MATERIAL SHALL BE A MINIMUM STRENGTH OF 6063-TS AND A MINIMUM NOTE 1 DETAIL A NOTE 2 DETAIL B OF 118"THICK. THE ALUMINUM STRUCTURAL MEMBER SHALL BE OF A SIZE TO PROVIDE FULL SUPPORT TO THE WINDOW FRAME SIMILAR TO THAT SHOWN IN THESE DETAILS FOR 2x WOOD BUCKS. THE ANCHOR SHALL BE A TYPICAL FLANGE FRAME HEAD SECTIONS #12 SHEET METAL SCREW WITH FULL ENGAGEMENT INTO THE ALUMINUM. IF THESE CRITERIA ARE MET,THE RESPECTIVE DESIGN PRESSURES AND ANCHORAGE SPACING FOR ANCHOR TYPE 2 MAY BE USED. 1/4 5.MATERIALS,INCLUDING BUT NOT LIMITED TO STEEL SCREWS,THAT COME INTO CONTACT WITH OTHER SHIM 13/8" 1/4"MAX.SHIM 1 1/4"MIN. DISSIMILAR MATERIALS SHALL MEET THE REQUIREMENTS OF FLORIDA BUILDING CODE. MIN. I I (1.5 KSI CMU) a OR 2-1/2"MIN.EMBEDMENT PER NOTE 1 IO (3.4 KSI CONCRETE) WOOD CONCRETE _ ANCHOR, ANCHOR, NOTE 2 n NOTE 1 1 314" EXTERIOR INTERIOR nEWN.EDGE ?• MIN.E.D (HEA &SILL DETAILS A,B,C. D, &H) TYP. 2x WOOD BUCK,NOTE 3 1x WOOD BUCK,NOTE 3 SEE NAILING INTERIOR 5J8"MIN.EDGE DETAIL E DETAIL F (JAMB DETAILS E,F&1) EXTERIOR TYPICAL FLANGE FRAME JAMB SECTIONS EXTEE 516MIN. CONCRETE WOOD V DETAIL H (HEAD) ANCHOR, ANCHOR, NOTE 1 NOTE 2 NAILING .131 DIA.MIN.x 21/2"NAIL PRODUCT REVISED AT CORNERS AND S"O.C. /� as complyiag with the Florida TYPICAL DETAILS G,H&I. U Building Code Acmplaaca�b 16'0 14.r3114" 1/4" @xpimtionDare 20 21 - MAX. MAX. SHIM SHIM Ry 0 /8"MIN.EDGE blianii nda prodoet SEE NAILING •NOTE 1 1 3/6"MIN. — 1-4 1 314"MIN. 2-1/2"MIN. L SEE NAILING E.D.TYP. MIN.3.4 KSI 1�,NmN•EbGE o CONCRETE 2x WOOD DETAIL C BUCK, DETAIL D 2-1/2"MIN.EMBED NOTE 3 DETAIL G(SILL) DETAIL I(JAMB) TYPICAL FLANGE FRAME SILL SECTIONS TYPICAL INTEGRAL FIN FRAME SECTIONS Y. E mar m. .• a a 4m 1070 TECHNOLOGY DR NE ANCHORAGE DETAILS -<r:-:•:;';N.VENICE,FL34276 ALUM.HORIZONTAL ROLLER WINDOW,IMPACT P.O.BOx 1529 q.",may. tLN: cea q DAN: NOKOMIS,FL 34274 Visibly Better s.lIX71e H` s� a'~m a""' A.LYNN MILLER,P.E. F.K 7!28/06 J.J. 323/08 7fa7f0 Half 11 m 11 4127-10 G P.E.#58705