Loading...
HomeMy WebLinkAboutProject Information Per our conversation today regarding FILE L� P 505 N 39th St Ft Pierce FI Scope of work Hang new interior doors, new cabinets&drywall. Install new tile on floors and bathroom shower wall. Paint all walls inside &outside. Electric Install-new wiring and breakers in breaker box. Install disconnect box for air handler and compressor. Install wiring for hot water heater. Install wiring for stove and refrigerator. Air Conditioning Install air handler, compressor and new a/c ducts Plumbing Install new water lines and drain piping in kitchen and bathroom. Install one outside faucet. Any questions please feel free to contact me. THESE PLANS AND ALL PROPOSED WORK Thank you ARE SUBJECT TO ANY CORRECTIONS REQUIRE®BY FIELD INSPECTORS THAT Ron Harry `.I�IAQf B9 NEC9.SSAR�i':Ids ORDER-TO . .tip,- F COMPLY, H ALL APPLICABLE CODES.' 11th-O)Zq ST.LUCIE COUNTY- 13UILDENG DIVISION REMWED TORWLIAIriCE REVIEWMAOAT) ._ � 151 PLANS AND PER-NUT N UST BE KEPT ON JQB OP,NO IINSPECTION WILL BE E. For any other electrical appliepti"s apply Florida Building Code 1073.5 Electrical S 0-510 /7• 3 cf 1- f 7 1. Wiring;Services;Feeders& ach Circuits;Over Current Protection;Groundi-' .�Tiring Methods&Materials;GFCI 2. Equipment 3. Special Occupancies app 4. Emergency Systems 5. Communication Systems F: j 6. Low Voltage 7. Load Calculations 8. Design Flood Elevation nderground Overhead 1.Size Service: 2.Conductor Size: CU ❑ ALUM 3.a.Meter Main: b.Meter Can Only: ❑ M Grounding Electrode Conductor Size ❑ #6 2'#4 ❑ #2 ❑ Other CONSTRUCTION TYPE: Residential Dual Electrodes or Test Required ❑ Mobile Home ❑ New Installation ❑ Old Installation TAb1&b1dg_fonns\New ApplieationsWorms0ectrical Riser Pfimdoc Rev.5129/12 Electrical Contractor: Phone Fax#• b Z Project Location: s0 S 1{T Existing Service Feeder Size: _ Existing Panel Size: '266 Main Breaker Size: 2 b O Number of Breakers: f O Existins Loads !QD F( Sq.Ft X 3 watts per sq.ft............................ 02 watts 2 Appliance cir.@1500 watts-each.................... a 00 watts FIL'11'1`,J / Laundry cir.@ 1500 watts each...................... I-ra 6 watts / Range @ 8 kw...........................................:..... X 0 0 watts T Dishwasher and disposal @ 1500 watts each......12 as watts Microwave @ 2000 watts.............................2Oc)c.) watts. Water heater @ 4.5 kw................................ 4r�3"41 c watts Tankless water heater................................. watts Dryer @ 5 kw........................................... •;rOOc, watts. Refrigerator @ 1500 watts 15"6 O watts Bathroom 1 @ 1500 watts .......................... y watts Sprinkler Pump ....................................... watts Other ............. watts Other ................. watts Other ................ watts Subtotal 3 2 2 Y watts New Loads Poolpump............................................... watts Poollight................................................. watts Heatpump............................................... watts Chlorine generator...................................... watts Airblower.............................................. . watts Boatlift..................................................... -watts Other ................ watts Other ............ watts Other watts Total watts /G Q Uo First 10 kw @ 100%.............................................. r o c5 ej s watts rA2c _Remainder @ 40%................................................... 9-Y watts —A/C heat @ 100%........................................................ PQ U o watts otal watts .Z 6 O Divided by 240 volts= 0 Amps Prepared by: 2 Date: TAbId\bIdgfonnsINew ApplicationsTormsElect ical Load Calculations dor 10/4/2007 Veronique Howley 13340 Alton Rd 1 Palm Beach Gardens Fl. 33418 Teh fa WH w D h a v! All new.Hot and Cold Water lines will be run _ over head in CPVC per code Drain lines will be tied in old cast lines and run in PVC per code Main water line inlet to house in CPVC inside in Copper line outside of wall 504 N 39th St