Loading...
HomeMy WebLinkAboutProject Information � � GENERAC® FEB 13 2017 / /22 PERMITTING GUARDIAN° SERIES St. Lucie County, FL Residential Standby Generators Air-Cooled Gas Engine INCLUDES: • True Power'" Electrical Technology Standby Power Rating • Two Line LCD Multilingual Digital Models G007036-0, G007037-0 (Aluminum-Bisque)-16 kW 60 Hz Evolution"' Controller(English/Spanish/ Model G007035-0 (Aluminum-Bisque)-16 kW 60 Hz French/Portuguese) Models G007039-0, G007038-0(Aluminum-Bisque)-20 kW 60 Hz • Two Transfer Switch Options Available: Models G007043-0, G007042-0(Aluminum-Bisque) -22 kW 60 Hz 100 Amp,.16 Circuit Switch or 200 Amp Service Rated Smart Switch. See Page 4 for Details. n ~� • Electronic Governor • System Status &Maintenance Interval LED �� 1 Indicators • Sound Attenuated Enclosure :BENE 1 �d • Flexible Fuel Line Connector • Direct-To-Dirt Composite Mounting Pad • Natural Gas or LP Gas Operation C&s LISTED QUI • 5 Year Limited Warranty Note:CUL certification only applies to unbundled units and units packaged with • Capability to be installed within 18" (457 mm) Z USA oiled nly switches.Units packaged with the Smart Switch are UL certified in of a building* *Only if located away from doors,windows and fresh air intakes, and unless otherwise directed by local codes. FEATURES O INNOVATIVE ENGINE DESIGN&RIGOROUS TESTING are at the heart of Generac's O SOLID-STATE,FREQUENCY COMPENSATED VOLTAGE REGULATION: success in providing the most reliable generators possible.Generac's G-Force engine This state-of-the-art power maximizing regulation system is standard on lineup offers added peace of mind and reliability for when you need it the most.The all Generac models.It provides optimized FAST RESPONSE to changing G-Force series engines are purpose built and designed to handle the rigors of load conditions and MAXIMUM MOTOR STARTING CAPABILITY by extended run times in high temperatures and extreme operating conditions, electronically torque-matching the surge loads to the engine. Digital voltage regulation at±1%. O TRUE POWER— ELECTRICAL TECHNOLOGY: Superior harmonics and sine wave O SINGLE SOURCE SERVICE RESPONSE from Generac's extensive dealer form produce less than 5%Total Harmonic Distortion for utility quality power.This allows network provides pads and service know-how for the entire unit,from the confident operation of sensitive electronic equipment and micro-chip based appliances, engine to the smallest electronic component. such as variable speed HVAC systems. O TEST CRITERIA: O GENERAC TRANSFER SWITCHES: Long life and reliability are J PROTOTYPE TESTED J NEMA MG1-22 EVALUATION synonymous with GENERAC POWER SYSTEMS. One reason for this J SYSTEM TORSIONAL TESTED J MOTOR STARTING ABILITY confidence is that the GENERAC product line includes its own transfer systems and controls for total system compatibility. w GENE R AC ,,Q,?•3ss ,�y4ti.� • _ •6®'� *®� Mobile PROMISE ' 2 �' Ltnk j�M6R� 'OBAA� •awl M ma USA u,oq'—ft-a Iare/pn wro. GENERAL" 16/20/22 kW features and benefits Engine • Generac G-Force design Maximizes engine"breathing"for increased fuel efficiency.Plateau honed cylinder walls and plasma moly rings helps the engine run cooler,reducing oil consumption resulting in longer engine life. • "Spiny-lok"cast iron cylinder walls Rigid construction and added durability provide long engine life. • Electronic ignition/spark advance These features combine to assure smooth,quick starting every time. • Full pressure lubrication system Pressurized lubrication to all vital bearings means better performance,less maintenance and longer engine life.Now featur- ing up to a 2 year/200 hour oil change interval. • Low oil pressure shutdown system Shutdown protection prevents catastrophic engine damage due to low oil. • High temperature shutdown Prevents damage due to overheating. Generator • Revolving field Allows for a smaller,light weight unit that operates 25%more efficiently than a revolving armature generator. • Skewed stator Produces a smooth output waveform for compatibility with electronic equipment. • Displaced phase excitation Maximizes motor starting capability. • Automatic voltage regulation Regulates the output voltage to±1%prevents damaging voltage spikes. • UL 2200 listed For your safety. Transfer Switch (if applicable) • Fully automatic Transfers your vital electrical loads to the energized source of power. • NEMA 3R Can be installed inside or outside for maximum flexibility. • Remote mounting Mounts near your existing distribution panel for simple,low-cost installation. Evolution" Controls • Auto/Manual/Off illuminated buttons -Selects the operating mode and provides easy,at-a-glance status indication in any condition. • Two-line LCD multilingual display Provides homeowners easily visible logs of history,maintenance and events up to 50 occurrences. • Sealed,raised buttons Smooth,weather-resistant user interface for programming and operations. • Utility voltage sensing Constantly monitors utility voltage,setpoints 65%dropout,80%pick-up,of standard voltage. • Generator voltage sensing Constantly monitors generator voltage to ensure the cleanest power delivered to the home. • Utility interrupt delay Prevents nuisance start-ups of the engine,adjustable 2-1500 seconds from the factory default setting of 5 seconds by a qualified dealer. • Engine warm-up Ensures engine is ready to assume the load,setpoint approximately 5 seconds. • Engine cool-down Allows engine to cool prior to shutdown,setpoint approximately 1 minute. • Programmable exercise Operates engine to prevent oil seal drying and damage between power outages by running the generator for 5 minutes every other week.Also offers a selectable setting for weekly or monthly operation providing flexibility and potentially lower fuel costs to the owner. • Smart battery charger Delivers charge to the battery only when needed at varying rates depending on outdoor air temperature. Compatible with lead acid and AGM-style batteries. • Main line circuit breaker Protects generator from overload. • Electronic governor Maintains constant 60 Hz frequency. Unit • SAE weather protective enclosure Sound attenuated enclosures ensure quiet operation and protection against mother nature,withstanding winds up to 150 mph.Hinged key locking roof panel for security.Lift�ut front for easy access to all routine maintenance items.Electrostat- ically applied textured epoxy paint for added durability. • Enclosed critical grade muffler Quiet,critical grade muffler is mounted inside the unit to prevent injuries. • Small,compact,attractive Makes for an easy,eye appealing installation,as close as 18"away from a building. Installation System • 1 ft(305 mm)flexible fuel line connector Absorbs any generator vibration when connected to rigid pipe. • Direct-to-dirt composite mounting pad Complex lattice design prevents settling or sinking of the generator system. 0 Integral sediment trap Prevents particles and moisture from entering the fuel regulator and engine,prolonging engine life. GENERAL 16/20/22.IcW specifications Generator 0 Model G007035-0,G007036-0, G007038.0,G007039-0 0007042-0,G007043.0 G007037.0(16 kW) (20 kW) (22 kW) Rated Maximum Conlmuous Power'Capactty(LPj _ 16 060w tts . "20,000 Watts" -42666" i' Rated Maximum Continuous Power Capacity(NG) 16,000 Watts' 18,000 Walls' 19,500 Rated foliage ;' 240; „ 240' 240 Rated Maximum Continuous Load Current-240 Volts(LP/NG) 66.6/66.6 83.3/75 91.6/81.3 TotaGHarmon[c Distiirtion 7 less thaa 5% Less than 5% Lessr(han 5%'.` Main Line Circuit Breaker 70 Amp 100 Amp 100 Amp 1 Number of Rotor Poles 2 2. . Rated AC Frequency" 60 Ht -66H _ fiOHz Power Factor 1.0'. . . _ .1-0 .,.. 1.0 Baltery,Requirement(not included) 12 Volts;,Group 26R 540 CCA Mimrnurn orGroup 35AGM,650 CCA Minimum ` Unit W6ight(lb/kg) 4061186 _ 448/203 4661211 Dimeruions(L x,W x H)tNmm _ 48 z 25 z 29/1218 x 63.8,i'732. Sound output in dB(A)at 23 it(7 m)with generator operating at normal load" 66 66 67 Sound output n._- at23 ft(7 rn)viitlf generator in—We Test'"lirw speed exercise modes Exercise duration 5 min ___ 5 min 5 min Engine Type of Engine GENERAC G-Force 1000 Series Numboi of Cylinders,'. Displacement 999 cc 9991 cc 999 cc CgllntlerBlock i41uminurn.w/Cast-IronSleeve . ,. Valve Arrangement Overhead Valve Overhead Valve Overhead Valve igmuan Sy§tem ; Sohd state w/Magneto` So_lidstate w/Magneto Solid stale w/Magneto Governor System Electronic Electronic Electronic Compresslun Ratio s :: 9 51 9.5:1 9.5., Starter 12 Vdc 12 Vdc 12 Vdc -0dCapacttylncluding Filter 'APProx.;1_:9 qV1 8 L Approx 19 gt/1.8 l Approx.l9 qt/1 8 L Operating rpm _ 3,600 3,600 3,600 Fuel Consumption v ,Natural Gas ;I f(3/hr(0lhr) 1/2 Load : 218(6,17) ;..204.(5.78)`. 216(6.12) v FulLLoad = 309(8;75) 301(8 52)` 310(878) Liquid Propane ft3/11r(gaUhr):[Uhr] 1/2 Load 916(2 52)(9 53) 86.(2.3 [8.99] 93.2(2:56)(9 70] y s FuII Load 106 8(2.94)[11 11] 129;6(3.56)[13:48] :; '',11Q(3.87)[14 65J' Note.Fuel pipe must be sized for full load.Required fuel pressure to generator fuel inlet at all load ranges-3.5-7°wafer column(7-13 mm mercury)for natural gas,10-121 water column(19-22 mm mercury) for LP gas.For Btu content,multiply 10/hr x 2500(LP)or 11%x 1000(NG).For Megaloufe content,multiply ma/hr x 93.15(LP)or ma/hr x 37.26(NG) Controls 2-Line Plain Text Multilingual LCD Display Simple user interface lot ease of operation. Mode Buttons Auto _ _ omahc Start on lJtilily.faI re.7 day exerciser. Manual Start with starter control,unit stays on.If utility fails,transfer to load takes_place. —�. Oft „ Stops untt.;Pgwer.is removetl Oonlr6l and char0ersttlfoperate r r_. _ Ready to Run/Maintenance Messages Standard Engine Run Hours indication Standard Programmable start delay between 21500 seconds Standard(programmable by dealer only) UUhty Voltage:LosslReturn to Utility Ad)ustable(Brownout Sailing) _ _ From 14017,1 V/190-216 V a' f Future Set Capable Exerciser/Exercise Set Error Warning Standard RuNAlarrNMamtenance Logs -� - 50 Events Each _ Engine Start Se uence 0 q Cyclic cranking:l6 sec on,7 rest(90 sec maximum duration Starter Ldck_oui _ Starter cannot re-engage;until;5 sec after engine has stbpped. " ` Smart Battery Charger Standard Chargerfault/MissingACWarnirfg _ ; :Standard, Low BalleryBatteryProblem Protection and Battery Condition Indication Standard AutbroaRe Voltage fie ulapon with Overand Under.,.,Volta a Protection = .g., _.... -.9. ._.. .._ '. . , ._;.'�`,..• . . ._- . .. ;: :- .: '. Standard�;; � �`r.'... Under-Frequency!Overload/Stepper Overcurrenl Protection Standard Safety fused/FUse Problem Prolaclion , ,. Standard Automatic Low Oil Pressure/High Oil Temperature Shutdown Standard OvercranfdOverspeed(C?12Hz)Jfpm Sense Loss Shutdowh - ndard High Engine Temperature Shutdown Standard ;Inteinal FaulNncorrecl Wtrmg Protection 3: :Standard- Common External Fault Capability Standard x Field llpgradabte Fumwaie , Standard "Sound levels are taken from the front of the generator.Sound levels taken from other sides of the generator may be higher depending oninsallatfonparameters.Ratingdefinitions-Standby.Applicable forsupptyingemergency power for the duration ~ of the utility power outage.No overload capability is available for this rating.(All ratings 1n accordance with BS5514,IS03046 and DIN6271).-Maximum ktlovolt amps and current are subject to and limited by such tactors as fuel BlWmegaloule content,ambient temperature,altitude,engine po verand condition,etc.Maximum pourer decreases about 3.5 percent for each 1,000 feet(304.8 meters)above sea level;and also will decrease about 1 percent for each 6`C(10`F)above 16'C(60°N. GENERACD 16/20/22 kW switch options Limited Circuits Switch Features Model G007036.0(16kW) • 16 circuits,breakers not included. No of Poles 2 = • curreni Rating(amps) log Electrically operated,mechanically-held contacts for fast,positive t _ 7 7 tJ connections Utility Voltage Monitor(Fixed)' • Rated for all classes of load,100%equipment rated,both inductive and -Pick-up 80% resistive. -Dropout 65% ' • 2 pole,250 VAC Contactors. Return'lo lJtiilty' J` _u. , '`approx 15_sec_ • 30 millisecond transfer time. Exercises bi-weekly for 5 minutest Standard • Dual coil design. uL�us�ed standam =`7 • Rated for both copper and aluminum conductors. Total circuits Available 1s • Main contacts are silver plated or silver alloy to resist welding and sticking. Circuit Breaker P ote�edbes • NEMA/UL 3R aluminum outdoor enclosure allows for indoor or outdoor Available RMS Symmetrical mounting flexibility. Fault current @ 250 Volts 10,000 • Multi listed for use with 1"standard.tandem,GFCI and AFCI breakers from *Function of Evolution Controller Siemens,Murray,Eaton and Square D for the most flexible and cost effec- Exercise can be set to weekly or monthly tive install. Dimensions Height Width H1 H2 W1 W2 Depth in 26.75 X0.1 10.5 13.5 6.91 H2H1 mm 679.4 764.3 266.7 343.0 175.4 Wire Ranges Conductor Lug Neutral Lug Ground Lug 1/0-#14 2/0-#14 2/0-#14 Service Rated Smart Switch Features Model 0007037-0(16 kW)/G007039.0(20 kW)/ • Includes Digital Power Management Technology standard(DPM). F;o 0007043.0(22 kW) Intelligently manages up to four air conditioner loads with no additional Current Rating(Amps) 200 }, hardware. ydltage Rating(VAC). 120/240 10 :; • Up to four more large(240 VAC)loads can be managed when used in UtdityVoitage Monitor(Fixed)* - conjunction with Smart Management Modules(SMMs). -Pick-up 80% • Electrically operated,mechanically-held contacts for fast,clean connections. Dropout 65% • Rated for all classes of load,100%equipment rated,both inductive and rests- SRetum to Utuity „ approx l3 sec `^:I live. Exercises bi-weekly for 5 minutes' Standard • 2 pole,250 VAC contactors. (OL ustetl standaro. • Service equipment rated,dual coil design. Enclosure Type NEMANL 3R • Rated for both aluminum and copper conductors. tCucwt Beaker Protected 22 goo ^ • Main contacts are silver plated or silver alloy to resist welding and sticking. Lug Range 250 MCM-#6 • NEMA/UL 3R aluminum outdoor enclosure allows for indoor or outdoor mount- Fupction of Evolution Controller ing flexibility. Exercise can be set to weekly or monthly Dimensions 200 Amps 120/240,10 Open Transition Service Rated _.. Height Width Depth ` H+ H1 I H2 W1 W2 in 26.75 30.1 10.5 13.5 6,91 mm 679,4 1 764,3 266.7 343.0 175.4 -.,TK' � GENERAC 16/20/22 kW available accessories 3 Modeh# Product Deseriptlon- j { Generac's Mobile Link allows you to check the status of your generator from anywhere that you have ac- G006463-4 i Mobile Link" �cess to an Internet connection from a PC or with any smart device. You will even be notified via e-mail orj text message when a change in the generator's status occurs. Available in the U.S.only. j G005819-0 26R Wet Cell Battery Every standby generator requires a battery to start the system.Generac offers the recommended 26R wet I I i cell battery for use with all air-cooled standby product(excluding PowerPact@). i , __._..---------- _. G007101 0 Battery Pad Warmer Jhe pad warmer rests under the battery.Recommended for use if the temperature regularlyfalls below 0°F I (Not necessary for use with AGM-style batteries). I 1,121007102-0 w Oil Warmer 011 warmer slips directly over the oil filter.Recommended for use if the temperature regularly falls below °F t Jhe breather warmer is for use in extreme cold weather applications. For use with Evolution controllers G007103-0 Breather Warmer only in climates where heavy icing occurs. jG005621 0 Auxiliary Transfer Switch !The auxiliary transfer switch contact kit allows the transfer switch to lockout a single large electrical load f ;Contact Kit ;you may not need.Not compatible with 50 amp pre-wired switches. 'Fascia Base Wrap Kit The fascia base wrap snaps together around the bottom of the new air cooled generators.This offers a i G007027-0-Bisque ! sleek,contoured appearance as well as offering protection from rodents and insects by covering the lifting (Standard on 22 kW) holes located in the base. If the generator enclosure is scratched or damaged,it is important to touch-up the paint to protect from i G005703-0-Bisque Paint Kit i future corrosion.The paint kit Includes the necessary paint to properly maintain or touch-up a generator 1 !enclosure. 1 _._i G006485-0Generac's scheduled maintenance kits provide all the hardware necessary to perform complete routine Scheduled Maintenance Kit }maintenance on a Generac automatic standby generator. G006873 0 Smart Management Modules are used in conjunction with the Automatic Transfer Switch to increase its i j ;Smart Management Module Ipower management capabilities.it provides additional power management flexibility not found in any other i (50 Amps) 'power management system. dimensions & UPCs Dimensions shorn are approximate.Refer to installation manual for exact dimensions.DO NOT USE THESE DIMENSIONS FOR INSTALLATION PURPOSES. 677.9 mm-- - ,z,9mm Model UPC r — rzs.,H, t.e.o ht rn ---- -- �r- G007035-0 696471070354 a G007036-0 696471070361 ?= G007037-0 696471070378 ,,T G007038-0 696471070385 r--Y G007039-0 696471070392 ° T ° of G007042-0 696471070422 ��/i/%/%/„,//moi,% i /'a%/' !// i/;%;i% G007043-0 696471070439 125.91n) ,7J2 mm 148.S IM LEFTSIDE VIEW PRONTVIEW GE N E RACO Generac Power Systems,Inc. • S45 W29290 HWY.59,Waukesha,WI 53189 •generac.com IIIIIINEEM9 ©2016 Generac Power Systems,Inc.All rights reserved.All specifications are subject to change without notice.Part No.10000000194-D 10/24/16 site selecfion and Preparation 3;1 WE SELECIUM t �b op�te wkiom or Openings in#M wag petmi�d F a.(1.52n)f many pots'ito fhe,gmWetz P P1861(A67MM) t r. 60th.(1624mm) MwMwn t'..t5iSM 60in.(1524mm) r r i i r JV{li. tOP of C-4n or —■+- y�µ{ �ii1i'fYii� Ctewwoe,from the sn&and mrd ohhee gwmW must be M.(914ram).This would Wkeds shrubs. These gupdefilM are based UPOn Ifffle, ML trees and M tctnd cNegelaflon shrterfm 12h ter t�,#c of the genera r endosure and (91� (Mmm)in frdgK Vegetattors Wertlsarr 12K ftrt nu is t tsirernerr€for air (sosmm)in tight must t a deamw of6t h lbw lbr proper operF�"ODn.Local. Codes (1ftnu m) 60hMew(MUM) *O sOW be a rrttnknEsrrt of 60pn.(1ti24rrutr)from any struathm may be dfftwd and snore rw�rtcOve oveinmv or projecstons fiam ft wait.7ha gawaWr #m what Is descAn#heare Mmld not be pfd under a deckcragwrabuchn ditisdotedMandmM oroo; tafrffaav 6W-(1��knm) mh nwn 601n.0524mm) min From Erb Generamr VBM mUM F4PV 3.1—WWWOn Wdeffnes low ft Fnalft set in its pmkz*,e MINLWO these WOW. r.W Om" vAh MFpA 37,Wj-,A,-%HFPA 58 and WPA 70 S2Arldffd-'k- The Mmation of the gmato, lea et.ri pmang*dS A CMM WOWN Or dMM,ConSkW water W&U,.l not rise wA w&nW k R should ret omte-in Or bs SOCted tO StFlxft VOW' we in mordame With,cuffat Ok" irrtathegenermonhogroww -�or m&twmc&and sm-cN.-ft WIR FRUSt be InBWA Akw~,room on ag-Ides of Ole Genmita- DONOTWW as=I as oftr des br mhm dbW=bM OtO S#UCbm NFpA 37 and WPA 70 dandaRls, d,stEjS8WIoa(* u nder moden ded's Or Mdum Unless them is gj ka�ait C1.52m)ei dwrM,SbMB th6 geReTIOr;3f'-PI M)Of deWM()n on SW fma MW a n*dmum of Ift.(457mm)of clearance;d ft bs*Of'-hO WtI- InsWI the uric where min guW down spout,TOOf mwiff,khjdX!8p--MgMDI,w&x WmkWm or sum pump&dmVe does not flood the uflft Or Spmy the erre,in d uft a nY&InWt Or m#J'd OMMOs- h)"the unk where$amm v9 no be a&cted or of d,md&Q cOPm-W underground or covered mviceS W-Kh 88 OW"fuel, phone,& or kwown.-1 to$could SW M"Cove e. Where strong Pma"VM&blvm Ibm one diredoft,tM ft MW- 8W 89 9,461 OPPIV lb b MON I WE&, III.SM fm gmmWr as dose as POSWOO 101te f1:43UTA-00 rM ft 4 40%REMER IMT LAWS OR COD5 MAY REW11 THE OFIANCE AND LON'M. fn$W the gmatv as dM as POSM8 b b M IS*Sft-POBSERINAT LAWS OR MS MAY RE N7 LATE THE DISTANM AND LOCATION, 1heg ) Jed on a{eve mftm.-me sanerabDr must 136 leve4 within ami pmm)am around. en.,&N mug,,.be ins& The generator is WLMW Plam Onpa qf ,wed sbW or a owa&-Pad.Che*local codes to see what We is required.If a CORDISIS *b M#4 aH Welal,*t.-&rj lmd cadn&dd be Mmed. 3.1.1 WSTALLKI-IOM GU ES FOR SA11OWYARtOOLED 8,11,13,14, 15,16,17 AND 20 KW GENMTORS The Naorag Fre Prdecdm Associdon has a sWWffd for to 1pawdm and use of sMmaiy=T"tm a0es.TM standard is M:PA 37,Its "bmeo bt the qmd%of an ffdosed germ&IN m from astmdure or wall(R-gme 1.19). NFM 37,Section 4.1 A,Enpm Locdad Outdoors:Sipes,and diek wed-aprce.bmk,--4o U provided,tid are hsWW outdoor sW be bcdad at Wd 51L(1.52m)from oW*.V In vaffis wW;d I. 5ft(1.62m)ft in slr€�ras haft cmbWbI9 iWis.A mWmurn mpardm shall not W raqukw witme etcher oft ie tfHoWQ MOM Mst 1. The a*Gent wag of the siructure has a fire resist a ra6g of et WAII hour. 2, T-Ile WedmMW fire is wnstructed of mncombi&*4e mdmi&aid k fm been demndmted that a ftAM!n the endosum VO not ignite 00mbUB&IO njemWa otAsIde the endmre AmmA—E-xPIWEftYMdDW A4.1.4(2)Me=of demon-&afing cmoiwm are by mem of fWj mate fie tea or by Odmilatim Procalm. BMW of to bied spaces that arebequeMy mal"tr WdabL R tm becm*.went thet mmepfion(2)would be bm*RM for RMY M$WedW MW comm Ndcd b*wWm.WM that in ntW,the amWeactum mi-&-azted VO an Wependani Laft WOW to run fd SmIa to b%t to awe W ft,endosure A not trite cmftsft mW.tm"mWetalies em-*mm. NOTE Scomeg Rmarch-WOM iOSM-9 aWmW 18m.(457PW bmwiatim mmmmm frm S#UdWe Ss rarest amm*is a MM"Agy rem9nmed thbdpfPY WS"&-W WOO AWY g AaTb Wift, *-&-gear and to detardries the iggnbbft off dr-am ouWe the erns erdosm he OONW=a to detm*ie ft vest cme fiewet at VXjOW&ft=.The efIdDSUPS 18 mmhmIed,of tm-cm Ae md%W,aid#*Mub and m4uslons twthe IR*WIdVttm*V lob M&dsd fA MY fire SMIn th9 ger mtx eFAm"vxW4 not PM M WOW oto nearby mnbusWes or enown,wNh or WW lire mvka ------------ sit a t. r -Wo -Qr-lftm G-nrautar A 't �erE -M FHM i ith Mum 0 aa" Sedan xA-t4 of F&PPA 37 F"3.2--Sotownst Research hisftfie Decal Qor t a the gorterator,flfvt to tft gwmaW's dW deW Based tart do$W_c&Q and W req&'e+��of*W 37.See 4.1.4, dews fw h ai�t€of gmen wed ate are =tot � Msic ske of tt;;get r to as wj=Her r .For add maat"Wome and eWow �,the area above the gemator s€uUM be at 6aO 41t(1.Mn)tea a ttMkm m ctf 3fc.(.91m)at to ftmt aria mWa of ft enc mtra'this , d irwuda trees,shnibs.td vegetOon sttot#sr din 12ht.(4tr3c)m hekjht Vegftm #m 121n.(306m)in heW n hm e dexamoe of eft.(152Arnm).Weon riot in compftroswb thm deffmce pararReLm tmid oiw ah-00W in atfditiort,exPtattstfines from the rhe rtet +xcxtud irtft �.See Figure 3.'i std ktsh t&atg YA tet ftomres ntattuai fo-deU&. Comteor adwAt cwttaW DEADLY carbW m momde gas,-ibis dertge M gas oan omm unc ormantsness or deA.Do not plain ft unit new yrs:,,dM(rash&Wes(ftmac m&.)or any t fkw in ffmbd ft o r sWwkm ineiucrng waindoa&and doom ofan aadmigut e. AW MMC-11� if the proal"is rm sa to dw OFF rte it cm€amik ad sW as sow as am bamy dies are cart ed.ffthe Lq ft power is not umied GO, cm amw aa ft hamy p#3Sa'end€au znt e> i rt, j. SMMEPAMON o Loco themoum tg atmcas c1m.as PsWeb theme S&A aidref su*j. a Laave a&W9b room wotmd dte area for m acm(diad ion!c ),aW06Geh9hW0wh to keep rfs�g vaafier from re tg die gam' e Chome m open span the irk!groves Were and unub& .-A a pWw the and so air ve&wtrt't bemme*ggsd, s9 Wm,stuttY er debt# Mafa sure exhaust furrt nct ear#rte kd t9 arra o eaves, fogs,vent on€arts oroth*�rad'DiWm( tt e8b Sdedmf ). Sded the type of bare,grant or mmmb,as desired or as rsgtited-1w, or cam.Ne your iocai requbmtertis bdara sefeft. 32.1 mMED STONE OR GRAVEL Dig a teomyt&-v area approx u0*atrt.(I27mn)deep ai?d auM ft.(I52mm)bW t wider ihwi the botpt of&a geneftr.Cover wdh poWeffmm fdm,t,deed,mid IM Y4&pea gtavQ orcnAPA stone.CvnP=t Md LdM ft sbrm A mrats pad can be priedIde9m#or regthd.Im pad should be Win.(102127 m'a)�c and xl art.rt52rm)aurid the outside o fire gezoata in a Miosis. MOTE. u a comm pad is requik4 in ag apElabte Fedarat,stm or fob rmim Q � �y^ T Cts \ and a�G Ya, f t Optional Load Calculation Heat later than Air C91r ) SF x 3V4 Living pHy = L0300 (2) small appliance ckis @ 1560VA ea = 3000 , Refrigerator @ 1500 Refrigerator @ 1500 - Freezer @ 1500 Washing machine @ 500 _ )Scats Dishwasher @ 1504 ! � Disposal @ 1500 Mini sewer @ 3000 Clothers dryer @ 5000 Range @12000 " Lc, 51 Water heater @ 4500.; _ LOC, 5kad 'Fixed microwave @ 15;00. vacuum.@ 1500 - Trash compactor C> 1500 - Pool heater @ 'name plate' ® Spa @ 'name plate' -Motors 746VA per HPI Ppm t 1 _ 350 i Totai "3 _ 2 First 10 KVA.of general load 6 i 00% = 10,000 3 Subtract Line 2 from 1 4 Multiply Line 3 @ [f0 6, 0 5 Add Lines 2 and 4 _ 6 60/50amp breaker for'heat f 14,0,446) 7 40/30amp breaker for Iheat(50li0) 8 Total heat-Add Lines 6�and 7` 9 Multiply Line 8 @-.&5 - l6 . 10 Add Lines 5 and 9i' ''• = c v�551 (Generator size needed) 1 1 Divide Line 10 by 240 : s - (Breaker size needed) S.'m: mmary: Line 10 is total t{w , Line I I Is total am s A ,