Loading...
HomeMy WebLinkAboutNotice of Acceptance PLUTSM' ALL PROPOSED WORK } File Copy AIE SUBJECT TO ANN CORRECTIONS REQUIRED BY FIELD INSPECTORS TEAT. MIAMI, P,j`1a x,8$90-'I Iik]0 Pa DER TO ' MIAMI-DADE COUNTY • rk' PRODUCT CONTROL SECTION � .�-- — �. _ _.- 11805 SW 26 Street,Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) Miami,Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T(786)315-2590 F(786)315 2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.gov/economy TRI-BUILT Materials Group,LLC . CONCEWD FASTENERS OR ATTACHMEk3 PO Box 70 Rutherford,NJ 07070 ARE THE RES PONSIMM Of THE SCOPE: WR OF REM This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be used in Miami-Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ). This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Section(in Miami-Dade County)and/or the AHJ(in areas other than Miami-Dade County)reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner,the manufacturer will incur the expense of such testing and the AHJ may immediately revoke,modify, or suspend the use of such product or material within their jurisdiction. REtZ reserves the right to revoke this acceptance, if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: TRI-BUILT Sand-R SA Shingle, month HT S/ nd S/A HT TU Underlayment Products LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials,use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply,with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County,Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA consists of pages I through 5. The submitted documentation was reviewed by Gaspar J Rodriguez. 11(;�.� "� �S77T,��L*UCT r�n`LJ g RIJ,T PTN1 DIVISION f,?. IY1F i�ED Fo.,.12. LLA1I0.v - rce,V£ ' -`vD DATE FLANS AND PEM-11T MUST fiE KEPT ON JOD NOA No.: 15-1123.06 r�aariianE couN1 r Expiration Date: 09/29/20 - - Approval Date: 04/28/16 Page 1 of 5 ROOFING COMPONENT APPROVAL Category Roofing Sub-Category: Underlayment Materials: SBS SCOPE: This acceptance is for TRI-BUILT Sand-R SA Shingle,Smooth HT S/A and S/A HT TU Underlayment Products, as described in this Notice of Acceptance, for use with approved prepared roof assemblies as described in this Notice of Acceptance;designed to comply with the Florida Building Code, including the High Velocity Hurricane Zone of the Florida Building Code. TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: Test Product Product Dimensions Suecification Description Tri-Built Sand-R SA Shingle 36"x 65'rolls ASTM D1970 Self-adhering glass fleece reinforced, SBS Underlayment modified bitumen roofing underlayment. Manufacturing Location#1-3 Tri-Built Smooth HT S/A 36"x 65'rolls ASTM D1970 Self-adhering glass fleece reinforced, Underlayment elastomeric bitumen roofing underlayment. Manufacturing Location#1-3 Tri-Built S/A HT TU 39 3/8"x 65 3/5' TAS 103 and Self-adhering glass fleece reinforced,SBS Underlayment rolls ASTM D 1970 modified bitumen roofing underlayment. Manufacturing Location#3 MANUFACTURING LOCATION: 1. Drummondville, Quebec(Canada) 2. Wadsworth, OH 3. Gulport,MS EVIDENCE SUBMITTED: Test A2ency Test Identifier Test Name/Revort Date Underwriters Laboratories,Inc. R21824 UL790 09/11/15 Trinity I ERD S40540.02.13-1 ASTM D1970 02/19/13 S40540.11.13 ASTM D1970 11/19/13 S43530.02.14-1-R1 TAS 103 05/14/14 544870.04.14-4 ASTM D1970 04/10/14 S44870.04.14-1 ASTM D1970 04/10/14 S44870.04.14-3 ASTM D1970 04/02/14 S40540.10.14 ASTM D1970 10/31/14 SOPC-SC8520.04.15 TAS 103 04/27/15 NOA No.: 15-1123.06 NAAMInA13ECOUNTY Expiration Date: 09/29/20 Approval Date: 04/28/16 Page 2 of 5 APPROVED ASSEMBLIES: ;Deck Type 1: Wood,Non-insulated Deck Description: 19/32° or greater plywood or wood plank System E(1): Base sheet mechanically fastened,membrane adhered. Base Sheet: One or more plies of ASTM D226 Type II or ASTM D2626 with a minimum 4" side lap and a 6" end lap mechanically fastened to deck with approved nails and tin caps 6" o.c. at the laps and two staggered rows 12" o.c.the field of the roll. Membrane: One ply of Tri-Built S/A HT TU Underlayment,Tri-Built Smooth HT S/A Underlayment or Tri-Built Sand-R SA Shingle Underlayment with minimum 3-inch side laps and 6-inch end laps. Starting at the first course,parallel to the eave, align the membrane carefully by completely unrolling and setting it exactly where it will be installed. Once aligned,rewind one half of the length. Gently score the release paper on the high side of this roll, ensuring not to cut through the membrane's thickness. Unroll this first half by evenly peeling back the release paper while simultaneously and slowly pushing out the membrane. Repeat process for remaining one half of the length. Once installed,the membrane must be pressure rolled with a metal or rubber roller. Pressure shall be applied over the entire surface,paying particular attention to all side and end laps. Surfacing: Approved for Mechanically Fastened Metal Roofing,Wood Shake&Shingles,Asphalt Shingles, Slate, Simulated Slate. Deck Type 1: Wood,Non-insulated Deck Description: 19/32" or greater plywood or wood plank System E(2): Base sheet mechanically fastened,membrane adhered. Base Sheet: One or more plies of ASTM D226 Type H or ASTM D2626 with a minimum 4" side lap and a 6" end lap mechanically fastened to deck with approved nails and tin caps 6" o.c. at the laps and two staggered rows 12" o.c.the field of the roll. Membrane: One ply of Tri-Built S/A HT TU Underlayment with minimum 3-inch side laps and 6-inch end laps. Starting at the first course,parallel to the eave, align the membrane carefully by completely unrolling and setting it exactly where it will be installed. Once aligned,rewind one half of the length. Gently score the release paper on the high side of this roll,ensuring not to cut through the membrane's thickness. Unroll this first half by evenly peeling back the release paper while simultaneously and slowly pushing out the membrane. Repeat process for remaining one half of the length. Once installed,the membrane must be pressure rolled with a metal or rubber roller. Pressure shall be applied over the entire surface,paying particular attention to all side and end laps. The Tri-Built S/A HT TU Underlayment shall be back nailed to deck with approved annular ring shank nails and tin caps at a maximum 12" o.c. at the side laps and 6" o.c. at the end laps. No nails or tin caps shall be exposed. Surfacing: Approved for Mechanically Fastened Cement or Clay Roof tiles. Tri-Built S/A HT TU Underlayment may be used with any approved roof tile system adhered as specified in their current NOA using any foam adhesive listed and having a current adhesive NOA approval. NOA No.: 15-1123.06 rowi'�MADECOUNTYM Expiration Date: 09/29/20 MW Approval Date: 04/28/16 Page 3 of 5 LINIITATIONS: .1. Fire classification is not part of this acceptance. 2. This acceptance is for prepared roofing applications. Minimum deck requirements shall be in compliance with the applicable building code. Tri-Built S/A HT TU Underlayment, Tri-Built Smooth HT S/A Underlayment or Tri-Built Sand-R SA Shingle Underlayment shall be installed in strict compliance with the applicable building code. 3. Tri-Built S/A HT TU Underlayment, Tri-Built Smooth HT S/A Underlayment or Tri-Built Sand-R SA Shingle Underlayment shall be applied to a smooth, clean and dry surface, free from irregularities. Re-fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust and debris prior to application. When a smooth, clean and/or dry surface cannot be obtained,the substrate shall be primed with Elastocol Stick prior to application. 4. Tri-Built S/A HT TU Underlayment,Tri-Built Smooth HT S/A Underlayment or Tri-Built Sand-R SA Shingle Underlayment shall not be applied over an existing roof membrane as a recover system but may be applied over a roofing Base/Anchor sheet underlayment. 5. Tri-Built S/A HT TU Underlayment is acceptable for use in foam adhesive set and mechanically fastened roof rile systems as specified in the surfacing option of the approved assemblies. 6. Tri-Built Smooth HT S/A Underlayment or Tri-Built Sand-R SA Shingle Underlayment shall not be left exposed as a temporary roof for longer than 30 days. 7. Tri-Built S/A HT TU Underlayment shall not be left exposed as a temporary roof for longer than 180 days of application. 8. Tri-Built S/A HT TU Underlayment,Tri-Built Smooth HT S/A Underlayment or Tri-Built Sand-R SA Shingle Underlayment may be used with any approved roof covering listing Tri-Built S/A HT TU Underlayment,Tri-Built Smooth HT S/A Underlayment or Tri-Built Sand-R SA Shingle Underlayment. If Tri-Built S/A HT TU Underlayment,Tri-Built Smooth HT S/A Underlayment or Tri-Built Sand-R SA Shingle Underlayment is not listed, a request may be made to the Authority Having Jurisdiction(AHJ)or the Miami-Dade County Product Control Department for approval based on the necessary documentation to detail compatibility of the products, wind uplift resistance and fire resistance results. 9. When applying the membrane in the valley, start at the low point and work to the high point,rolling the membrane from the center outward in both directions. For ridge applications, center the membrane and roll from the center outwards in both directions. 10. Membrane shall be applied to protrusions, slope changes,valley, curb, and other roof top penetration details before any other sections of the roof. rLar�i os+DE caur�rr NOA No.: 15-1123.06 Expiration Date: 09/29/20 - Approval Date: 04/28/16 Page 4 of 5 11. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and • Rule 61G20-3 of the Florida Administrative Code. 12. Tiles must be staged onto Tri-Built S/A HT TU Underlayment not to exceed 10-high,to the standard maximum roof pitch of 6:12 for flat tiles and 5:12 for lugged riles. Lugged tiles staging at slope>5:12 shall use alternate staging method(bottom tile shall be inverted followed by eight tiles high on slope,as illustrated in Figure 1 below). } 1 i Figure 1: Alternate Staging Method At roof slopes greater than the preceding limitations all tiles shall be loaded onto a nominal 1" x 2"horizontal batten to prevent slippage. 13. All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo, city,state and the following statement: "Miami-Dade County Product Control Approved" or the Miami-Dade County Product Control Seal as shown below. MIAM6DADE COUNTY END OF THIS ACCEPTANCE � NOA No.: 15-1123.06 MIAMIDADECOUNTY Expiration Date: -1123.06 -- Approval Date: 04/28/16 Page 5 of 5 _11 LT,il� =TRI-BUILT' MATERIALS GROUP, LLC hd oil t TRI-BUILT®MATERIALS GROUP, LLC "WW4VtTlbUilGlllg -om I 1=$QO $16 14$5 T11-991M Smooth HT S/A godor6oymoot DESCRIPTION TRI-BUILr SMOOTH HT S/A Underlayment is a SBS modified bitumen membrane reinforced with a fiberglass mat.The self-adhesive underface is covered with a split back silicone release film.The top face is composed of a non-slip plastic surface. TRI-BUILT®SMOOTH HT S/A Underlayment is used as a waterproofing membrane under metal roofing or as an eaves protection under asphalt shingles roofing and other roofing materials. Apply to clean,dry surfaces of plywood,OSB or asphalt panels.Product can be left exposed up to 60 days under certain conditions. Application temperature:40 to 122 OF(4.5 to 50°C) Service Temperature:-49 to 220 OF(-45 to 104°C) RECOMMENDED USES PACKAGING & COVERAGE • Metal roof underlayment for edges and details: Rolls of 3 ft x 65 ft(0.91 m x 19.8 m)covering —Dormers approximately 195 ft'(18 m2). —Valleys 36 rolls per pallet —Ridges —Vents —Skylights —etc. • Eaves protection on medium to high slope roofs PROPERTIES SMOOTH Thickness Reinforcement:' Glass Mat: Surface Anti-S.. , lip Plastic Film " lJnderface -Split-Back Silicone Release Film Roll weight a 49 lb(22.3 kg) Tensile Strength,MD/XD ASTM D1.970 72.1 1,43.7)bf/in'-(12.6/7.6 kN/m)_ Elongation at Bregk MD%XD ASTM D1970 29/3'1 7a- ' Tear Resistance: ASTM DI 970 1;03/74 lbf'(458/.329 N). 'Static Puncture ASTM D5602 _'83.9 Ibf(373 N) .Ad esion to Plywood'75.7°F 240C), ASTM D1970 25 31bf/ft(11.5 kgf_/30:5 cm) Low Temperature Flexibility ASTM-D1970 20°F-(-29°C Water Vapour Permeance -ASTM 0:04.perm,(2:4 ng/Paes•'mZ) M E9 Nall Sealability ASTM D1970 Pass ' (All.values are nominaq RESTRICTIONS • Do not apply directly onto wood planks.Cover surface with plywood or OSB panels prior to the membrane application. •Verify for safety that membrane is not dusty,wet or icy to keep its maximum anti-slip property. • It is not recommended to use an elastomeric bitumen membrane directly on softwood boards or on flexible polyvinyl chloride. STORAGE Can be stored at temperatures below 32 OF(0°C),but must be conditioned 24 hours at minimum 40 IF(4.5°C)before its use. Keep upright at all times. ��.SSfpj�® aR�aAREnRoow+anccEssoRr AS TDAN EXfD INALFlRE EXPOSURE 1YV�IY YD ,,,,Q,AN EXMR , REE FLORIDA BUILDING CODE(FBC) C ®L U$ As IN81'RuanON91NQLDED FL16048-R4 WrrH THE PREPARED ROORNG No+,s.,,rioe RISO14 ,000000r ESR-3492F TBS140 TB Smooth HT SA Underlayment 11/10/2016 TRI-BUILT Materials Group,LLC•P.O.Box 70 •Rutherford,NJ 07070