Loading...
HomeMy WebLinkAboutEngineering 1 Peter M.Wisniewski,Architect 2801 N. Highway A1A,Apt. A Fort Pierce, FL 34949 RIECOw February 14, 2017 FEB 16 2016 St. Lucie County Public works Planning and Development Services St. Lucie county, FL Building and Code Regulation Division 2300 Virginia Avenue Fort Pierce, FL 34982 i Re: Plan review fo 1702-02( 2 Alfred Copeland Couric, III 2711 N. Highway A1A,Apt.J North Hutchinson Island, FL Dear Building Department: Comment#1: Two water resistive barrier are required per FBL R703.6.3 between the 5/8" plywood and the stucco. Response#1: Please see revised letter dated February 14, 2017 Comment#2: Please provide the product approval (2 copies)for the required Mullion Tube for the installation of the side by side PGT SH700 windows or revise the product review table to include the Mullion Tube FBC 107.1. Response#2: Il_haue�attach4d 2 copies of the Product Approval for the Mullion Tube ell oP.�f e . r; Isn e ,ski;,Architect •CRY- .-' �*_--5.:�w zti•�.�. e Peter M.Wisniewski,Architect 2801 N. Highway AIA,Apt. A - Fort Pierce, FL 34949 x x February 8, 2017 4: St. Lucie County IAZI, Planning and Develop m`etit Services Building and Code Reg ulaon Division �- 2300 Virginia Avenue Fort Pierce, FL 34982 e .V Re: Alred Copeland C�oUric, III 271�'V. Highway✓A1A,Apt.J North;,WutchirY`s(on Island, FL i. Dear Building Department: 5 � �F �Y�p� Please be advised that the wall comp" sition at tl address referenced above will be 2 by 4 wood studs @ 24"o.c. with 5/8 CDX plywood with per back wire lathe and 5/8" brown coast stucco and % inch finished stucc"With paint. f� N� Yours truly, Peter�Wisni wski, chitect FL#AR0012606- �r, I fff i ltttffff EXISTING METAL ' + ' ROOF i T� 1 EXISTING WOOD TRIM f TO BE REMOVED f _ I f d EXISTING STUCCO PATCH i TO MATCH EXISTING i I WEST ELEVATION 2ND FLOOR (2 3650 S.H. ,EXISTING DECKTO BE a5T FLOOR d ,� _ REMOVED - -- i- EXISTING DOORS TO BE REMOVED i Jam_-' NEW 306 FIBERGLASS DOOR 3738S.H. INSTALL NEW LIGHT FIXTURE PETER M.WISNIEWSKI,ARCHITECT, FL. LICENSE#AR0012606 OWNER: ALFRED C. COURIC III 2801 N-.,HIGHWAY A1A,APT:A 2711 N. HIGHWAY A1A,APT.J FORT PIERCE, FL 34949- '_- FORT PIERCE, FL 34949 236-464-5665 DATE:_-February 8,2017 Certification for"Design Load Compliance 1. Design Code:Florida Residential code 2014 Edition w/20_supplements using ASCE 7-10 , 2. Structure Design is: X Enclosed Partially Enclosed Open Building 3. Risk Category: I X II III IV Exposure Category _B X C_D Adjustment coefficient 11.21 4. Design Wind Velocity 165 mph ASD LRFD End Zone Width 3'-6"ft. 5. Mean Roof'Height: Existins ft. Roof Pitch: Existins:12 Parapet: ft 6. Components&Cladding Design Pressure used: (PSF, based on Actual sq.ft. @ 30' MRH (Worst Case) Zone 1: N/A Zone 2: N/A Zone 3:N A Zone 4:61.7 Zone 5:-74.1 Garage: N/A 7. Design Loads: Floor Exist PSF Roof/Dead: Exist PSF Roof/Live: Exist PSF Balcony: PSF Dock: PSF Deck: PSF Stairs: PSF Fence: PSF Railings: PSF 8. Were Shear Walls Considered for Structure? Yes X No Not applicable Explain Why Not:Existing 9. Is a Continuous Load Path Provided? Yes Not Applicable Explain Why 10. Design Soil Bearing Pressure: N/A PSF Soil boring Test required: Yes X No(based upon section 1803.2 a exception) PRODUCT REVIEW PRODUCT OPENING DESIGN PRODUCT MANUFACTURER MODEL# APPROVALS GLASS ATTACHMENT METHOD PRESSURES DESIGN.. TYPE (WORST CASE) PRESSURES 'WINDOW ZONE 4—56.5 +64.0/-80 PGT INDUSTRIES SH700 NOA# IMPACT Y4" ULTRACON @17-3/8"MAX.AND ZONE 5—64.5 16-0714.06 SOLAR 6-1/2" MAX. FROM EACH CORNER, HEAT WITH A 1-3/4"MIN. EMBEDMENT AND GAIN 2-1/2" MIN. EDGE DISTANCE . 0.53 DOOR ZONE 4-47.9 /+50THERMA-TRU GLAZED FL15225R3 IMPACT %"TAPCONS @11.50 MAX O.C.WITH A ZONE 5-57.5 CORP. FIBERGLASS 1-1/4"MIN EMBEDMENT AND 2"MIN DISTRANCE TO EDGE - THE SEAL HEREON IS PROVIDED ONLY TO INDICATE OUR REVIEW AND APPROVAL FOR USE OF PRODUCTS LISTED FOR THIS STRUCTURE. THE ACCEPTANCE OF THESE PRODUCTS�AND METHODS OF ATTACHMENT ARE BASED ENTIRELY UPON TEST DATA PROVIDED BY THE MANUFACTURER, HIC RRIES IT OWN�'ENG EER'S CERTIFICATION AND IMPLIES NO WARRANTY OR GUARANTEE BY THIS ARCHITECT FOR THESE PRODUCTS. EKE P:ETE.R M.1 N WSKI °ARCHITECT, FL. LICENSE#AR0012606 OWNER: ALFRED C. COURIC-III 2901N. HIGHWAY.AIA,APT.A 2711 N. HIGHWAY AIA,APT.J FORT,PIERCE, FL 34949 FORT PIERCE, FL 34949 t 236-464=5669 DATE.. February 8, 2017 NOTES: STUCCO ON RIBLATH OR PAPER BACK SHALL BE ATTACHED TO HORIZONTAL FRAMING AS PER ASTI'uI C-2063: LATH SMALL BE ATTACHED TO FRAMING MEMBERS WITH CORROSION RESISTANT MATERIALS. ATTACHMENTS SHALL BE SPACED NOT MORE THAN 6"O.C.ALONG SUPPORTS. FASTENERS TO BE USED CAN . ' BE 6D COMMON OR ROOFING NAILS HAVING A MIN.%"PENETRATION INTO HORIZONTAL FRAMING 1 MEMBERS OR STAPLES W/A TONIN.%"CROWN ENGAGED NOT LESS THAN(3)STRANDS OF LATH AND MUST 4 PENETRATE THE WOOD FRAMING MEMBERS%"MIN. STRAP STUD TO EX. FRAMING ABOVE WITH SIMPSON LSTA 12 W/14-10d NAILS , y of ' HEADER 2 X 6 W//2„ p BAIL NEW �{ PLYWOOD SPACER GLUED �� t � DEADER STUD &NAILEDW/16d NAILS @ g ` TOGETHER 1 8”o.c.STAGGERED BOTH t [ W/16D NAILS IDES. @8-O.C.STAG / t 2 X 4 STUDS AT 16"o/c 2"X4"STUDS `l WIND®W OPENING SIMPSON GA-1 STUD TO STRAP EACH STUD WITI { S { PLATE H SIMPSON SP4 WITH 6- 10d X 1%2" NAILS STRAP STUD TO EX. 2"X 4" PLATE ANCHORED WITH FRAMING BELOW WITH 3/8"X5 LAG BOLTS @24" o.c. MAX SIMPSON LSTA 12 W/14- FOR SECOND FLOOR. 10d NAILS 2"X 4" P.T. PLATE ANCHORED WITH 3/8" RED HEAD WEDGE ANCHORS INTO SLAB AT 24"o.c. FOR FIRST FLOOR PETER M.WISNIEWSKI,-,ARCHITECT, FL. LICENSE#AR0012606 OWNER: ALFRED C.COURIC III 2801 N. HIGHWAY AIA,APT.A 2711 N. HIGHWAY A1A,APT.J FORT PIERCE, FL 3,4949 FORT PIERCE, FL 34949 239-464-5669 DATE: February-8,2017 PETER M.WISNIEWSKI,ARCHITECT, FL. LICENSE#AR0012606 OWNER: ALFRED COURIG 2801 N. HIGHWAY AIA,APT.A 2711 N. HIGHWAY AIA,APT.1 FORT PIERCE, FL 34949 FORT PIERCE, FL 34949 239-464-5669 .DATE: February8,2017 Y 5/8 CDX PLAYWOOD �/SHEATHING, USE 8d. NAILS I g@16"o.c. SIDE VIEW ADD 1 STUD TO EXISTING 2 x 4 STUD WALL @ SIMPSON GA I EXISTING 24"o.c. 1 STUD TO 2 16-d @EX. 2 X 4 PLATES TWO SIMPSON GA 1 STUD TO PLATE - „ STUDS @ BOTH SIDES 12 o.c. REMOVE DAMAGED TRUSS li W JOIST 24" o.c. OF STUDS EXISTING TRUSS JOIST $ P FORM NEW MEMBERS 2-2X10 TO REMAIN PLYWOOD SPACER I '. ADD 12X4 STUD TO EXISTING EXISTING STUD WALL 2 X 4 PLATE �• 2-16d NAILS NEW DBL 2 X 10 JOIST 16'LONG, SECTION THRU JOIST THRU BOTTO HGUS210-2 JOIST HANGER OF PLATE 2X4STUD v GA 1 STUD TO PLATE STRAP STUDS TO EX. FRAMING BELOW WITH SIMPSON a —2 X 4 PLATE LSTA 12 W/14-10d NAILS s. 2 2 X 10 WITH%" PLYWOOD SPACER GLUED&,NAILED CALCS: g W/16d NAILS @ 8"o.c. JOIST Ln= 16'22*= DL 40= LL - i STAGGERED BOTH SIDES M=3968'sq SM req =34.0' in cu 0 = 192/360=.53 JOIST DETAIL I req =195.5"sq DBL 2 x 10=SM=48.8.in cu DBL 2 x10 =SM=48.8 in cu 1=232" sq OK