HomeMy WebLinkAboutProduct Approval S: Ce>f>icate ofAuthorizatron No.29824 17520 Edinburgh Drive LE-01.KTampa,FL 33647 TECHNICAL SERVICES, ]. Lc (813)480-3421 EVALUATION REPORT n FLORIDkSUILDING CODE 5T"EDITION(2014) Manufacturer: ALPHA PROTECH ENGINEERED_PROD C-M' NO. Issued June 22,2095 301 South Blanchard Street Valdosta,GA 31601 (229)242-1931 htto://www.alphaprotech.com Manufacturing Locations: Valdosta,GA Quality Assurance: RADCO,Inc.(QUA1990) SCOPE Category: Roofing Subcategory: Underlayments Code Sections: 15072.3,1507.3.3,1507-5.3,1507.7.3,1507.8.3,`1507.9.3 Properties: Physical properties REFERENCES Entity Report No. Standard Year PRI Construction Materials Technologies(TST5878) AEP-017-02-01 ASTM D 226 2006 ASTM D 4869 2005el RADCO,Inc(TST1987) RAD-5212 AC 188 2012 Ramtech Laboratories,Inc.(TST6127) 13075-04-08 AC 188 2012 PRODUCT DESCRIPTION REXT'"SynFelt A mechanically attached,woven polypropylene underlaynment(nominal weight=2.56 lb/100fp)used an alternative to'ASTM D 226,T ,I:and Type II roofing underlayments, R©Ctreme A mechanically attached,woven polypropylene uKfedayment(nominal weight=2.97 Ib/100f?)used an alternative to ASTM D 226,Typ i and Type II roofing undedayments TECHNOply A mechanically attached,woven polypropylene unrlayment(nominal weight=2.05 Ib/100l?)used an alternative to ASTM D 226,Typa,f•and Type II roofing underlayments TECHNO SS A mechanically attached,woven polypropylene uriderlayment(nominal weight=2.00 lb/100f?)used an alternative to ASTM D_226,Typo I and Type 11 and ASTM D 4869, Type 11 and IV roofing underlayments APPLICATION INSTRUCTIONS Deck Type: The roof deck shall be constructed of closely fitted; solid sheathing for new or existing construction. Sheathing shall be installed In accordance with FBC requirements. Roof decks shall have no more than°/s"gap at abutting joints. Min.slope: 2:12.For slopes less than 4:12,the underlayment must be half-lapped a full 24"over the underlying course. Attachment method: Underlayment shall be attached in accordancn•'with the FBC and manufacturer's Installation instructions. At minimum, mechanically fastened with min. 12 ga. corrosion resistant ring shank nail with min.14nch diameter corrosion resistant round cap to a min. 314-Inch penetration, 8" o.c. at side and end laps and 24" o.c in a staggered pattern along the center lines printed on the sheet.The side laps shall be a minimum 3"wide APT15001.1 FL12512-R4 Page 1 of 2 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty,installation,recommended use,or other product attributes that are not specifically addressed herein. ALPHA PROTECH ENGINEERED PRODUCTS,INC, CREEK Underlayments TrrcmicAL SERvims,LLC ;f. and minimum 6"wide at the end laps, The underlayment is Installed starting at the eave, with the length of the roll parallel to the eave with the printed side facing up. All side laps shall be installed to shed water from the deck. Allowable roof coverings: Asphalt shingles,slate shingles, clay and concreto tiles,metal roof panels and shingles, wood shakes and shingles LIMITATIONS 1) Th Is evaluation report is not for use In the'HVHZ. 2) Fire Classification is not within the scope of this evaluation. 3) Wind uplift resistance Is not within the scope of this evaluation. 4) Installation of the evaluated product shall comply with this report,the FBC,and the manufacturer's published application instructions. Where discrepancies exist between these sources,the more restrictive and FBC compliant installation detail shall prevail. 5) Deck substrates shall be clean, dry, and free'from any,..irregularities:and debris. All fasteners In the deck shall be checked for protrusion and corrected prior to underlayment do kation. 6) The roof deck shall be constructed of closely fitted sheathing for new:or existing construction. Roof deck shall be installed in accordance with FBC requirements, 7) Unless otherwise stated,the minimum roof slope shall be in accordance with FBC requirements. 8) All underlayments shall be Installed with the roll length parallel to the-'eave,starting at the eave,and lapped in success courses installed up the deck In a manner that effectively';*keds water from the deck. End laps shall be staggered between courses in accordance with the manufacturer's application instructions, 9) Contact the manufacturer when installing at temperatures below the minimum application temperature, 10) The underlayment may be used as described in other current FBC product approval documents. 11) Roof coverings shall not be adhered directly-to the-underlayment, .foof coverings shall be mechanically fastened through the underlayment to the roof deck. 12) The underlayment shall be exposed on the roof deck for a maximum 30 days unless otherwise stated, 13) All products listed in this report shall be manufactured under a quality-assurance program in compliance with Rule 61G20-3. COMPLIANCE STATEMENT The products evaluated herein by Zachary R. Priest, P.E. have demonstrated"compliance with the Florida Building Code&.Edition(2014)as evidenced in the referenced documents submitted 6,.the named manufacturer. 1114 �,....:: 2015.06.2 A. 44 04'00' y,+ ;" �• Zachary R.Priest,P.E. q`1 =.:: .: : :::•,.��,� ,:.,K:, .�,,.;.C�;�z.:::•:.,: Florida Registration No.74021 :::"r+ftj ? + i�',.`;:.•.a. •., ..;,.0rganizationNo.ANE9641 CERTIFICATION OF INDEPENDENCE CREEK Technical Services,LLC does not have,nor will it acquire,a financlal Interest In any comparymanufacturing or distributing products under-this evaluation.. CREEK Technical Services,LLC Is not owned,operated,or controlled by any company manufacturing or distrlbuting products under this evaluation.' Zachary R.Priest,P.E.does not have,nor will acquire,a financial interest in any company manufacturing or distributing products under this evaluation. Zachary R.Priest,P.E.does not have,nor will acquire,a financial interest in any other entity Invoived,16-the approval process of the product. END OF REPORT APT15001.1 FL125i2-R4 Page 2 of 2 This evaluation report is provided for State of Florida product approval under Rule 61 G20'-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throug46ut the duration for which this report is valid. This evaluation report does not express nor Imply warranty,Installation,recommended Use,or other product attributes that are not specifically addressed herein.