Loading...
HomeMy WebLinkAboutNotice of Acceptance MIAMIMf;� MIAMI-DADE COUNTY oDADE PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES' ER BOARD AND CODE ADMINISTRATION DIVISION ( 11805 SW 26 Street,Room 208 Miami,Florida 33175-2474 NOTICE OF ACCEPTANCE OA wwxv.miamidade.eovleconomv Sun-Tek Manufacturing,Inc. ` ' 10303 General Drive. �_ Q Orlando,FL 32824 Jt� SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be used in,Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Section(In Miami Dade County)and/or the AHJ(in areas other than Miami Dade County)reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify,or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product'is approved as described herein, and has been designed to comply with the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: ICMG Skylight System APPROVAL DOCUMENT: Drawing No. STI-00000290,titled"ICMG",sheet I &2 of 2,prepared by Sun-Tek Manufacturing, Inc.,dated August 07,2007,with last revision"A"dated May 03,2012,signed and sealed by James D.Wells,Jr., P.E.,bearing the Miami-Dade County Product Control Revision stamp with the Notice of Acceptance number and the expiration date by the Miami-Dade County Product Control Section. MISSILE IMPACT RATING: Large and Small Missile Impact Resistant LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo,city,state,model/series and the following statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials,use,and/or manufacture of the product or process.Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade,County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises&renews NOA#12-1011.16 and consists of this page 1,evidence submitted pages E-1,E-2, & E-3 as well as approval document mentioned above. The submitted documentation was reviewed by HyImy A.Makar,P.E.,M.S. I NOA No. 13-1010.09 MIAMI•DADECOUNTYc. � - .�� ;� ��. Expiration Date: 10/10/2018 r Approval Dates 05/08/2014 o,5 Page 1 Sun-Tek Manufacturine,Inc. NOTICE OF ACCEPTANCE:EVIDENCE SUBMITTED 1. EVIDENCE SUBMITTED UNDER PREVIOUS APPROVAL#07-0425.05 A. DRAWINGS 1. Drmving No. STI-00000290-SHTIISH72, titled "ICMG'; sheet I & 2 of 2,prepared by Stat- Tek Mamifacturi»g, Inc, dated 06104107, with last revision dated 08107107, signed rnid sealed by James D. Wells,Jr., P.E. B. TESTS(submitted under NOA#02-0729.07) 1. Test Report on Large Missile Impact Test per PA 201, Cyclic Wind Pressure Test per PA 203 and Uniform Static Air Pressure Test per PA 202 of "Model ICMG 4949 Insulated Glass Skylight with Polycarbonate Inner Liner" prepared by National Certified Testing Laboratories, Report No. 210-2789-1, 2 & 3, dated 03/18/02, signed and sealed by B.Portnoy, PE. C. CALCULATIONS - 1. Anchor Calcidations for attachment of skylight to cubing and cm-bing to decking, dated 08/13/07, signed and sealed byJaines D. Wells,Jr., P.E. D. MATERIAL CERTIFICATIONS(submitted under NOA#02-0729.07) 1. Die drawings No. STI-214 of Deco Ring, prepared by Sun-Tek Mant factturing, Inc, on 6/19/95. 2. Die drmving No. STI-205 of Curb Frame prepared by Sun-Tek Mantifacturing, Inc. on 12126/96. E. STATEMENTS (submitted under NOA#02-0729.07) 1. Code coinpliance and No-Interest letter issued by Product Technology Corporation on 08127/02, signed and sealed by R.J. Quiroga PE. F. OTHER 1. NOA renewal request letter isstied by Stin-Tek Manufacturing, Inc., dated 08116107, signed by Jantes Feiidner. 2. EVIDENCE SUBMITTED UNDER PREVIOUS APPROVAL#11-0601.03 A. DRAWINGS 1. Drawing No. STI-00000290-SHTUSHT2, titled "]CMG", sheet I &2 of 2,prepared by Stin-Tek Manufacturing, Inc., dated Atigiist 07, 2007, with last revision "A" dated October 14, 2011, signed and sealed by James D. Wells, Jr., P.E. 4fWmy A.Makar,P.E.,M.S. Product Control Unit Supervisor NOA No. 13-1010.09 Expiration Date: 10/10/2018 Approval Date: 05/08/2014 E-1 Sun-Tek Manufacturing,Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED B. TESTS 1. Test Addendum for Test Report NCTL 210-2760-1, prepared by national Certified Testing Laboratories, dated October 17, 2011, certifying the interlayer thickness, signed by Mark Bennett, Manager of Testing Services(see NOA911-0601.02). C. CALCULATIONS 1. None. D. QUALITY ASSURANCE 1. By Miand-Dade Counfy Department of Permitting, Environment, and Regulatory Affairs (PERA). E. MATERIAL CERTIFICATIONS 1. None. 3. EVIDENCE SUBMITTED UNDER PREVIOUS APPROVAL#12-1011.16 A. DRAWINGS 1. Drmving No. STI-00000290, titled "ICMG", sheet I & 2 of 2, prepared by Sun-Tek Manufacturing, Inc., dated August 07, 2007, with last revision "A" dated May 03, 2012, signed and sealed by James D. Wells, Jr., P.E. B. TESTS 1. None. C. CALCULATIONS 1. None. D. QUALITY ASSURANCE 1. By Miami-Dade County Department of Regulalw y and Economic Resources. E. MATERIAL CERTIFICATIONS 1. None. F. OTHERS 1. A compliance letter, prepared by J& L Wells Consulting LLC, dated April 25, 2012, certifying compliance with FBC 2010 edition, sign and sealed by James D. Wells, Jr., P.E. 2. Verification testing to be performed per letter from National Certified Testing Laboratories, dated September 18, 2012, signed by Christopher Bennett. lye y A.Makar,P.E.,M.S. Product Control Unit Supervisor NOA No. 13-1010.09 Expiration Date: 10/10/2018 Approval Date: 05/08/2014 E-2 z , Sun-Tek Manufacturing,Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED 4. NEW EVIDENCE SUBMITTED A. DRAWINGS 1. Drawing No. STI-00000290, titled "ICMG", sheet I & 2 of 2, prepared by Sun-Tek Manufacturing, Inc., dated August 07, 2007, with last revision "A" dated May 03, 2012, signed and sealed by James D. Wells, Jr., P.E. B. TESTS 1, Test Report on Large Missile Impact Test per PA 201, Cyclic Wind Pressure Test per PA 203 and Uniform Static Air Pressure Test per PA 202 of "Model ICMG 4949 Insulated Glass Skylight with Polycarbonate Inner Liner" prepared by National Certified Testing Laboratories, Report No. 210-3915-02, dated 09/13/13, signed and sealed by Gerard J. Ferrara, P.E., on 09124/13. 2. Revised Test Report on Large Missile Impact Test per PA 201, Cyclic Wind Pressure Test per PA 203 and Uniform Static Air Pressure Test per PA 202 of"Model ICMG 4949 Insulated Glass Skylight with Polycarbonate Inner Liner"prepared by National Certified Testing Laboratories, Report No. 210-3915-02, dated 09/13113, revised on 02/26/14, signed and sealed by Gerard J. Ferrara, P.E., on 02128/14. C. CALCULATIONS 1. Anchor Calculations for attachment of skylight to cubing and curbing to decking, dated 10/03/13, signed and sealed by James D. Wells, Jr„ P.E., on 10/03/13. D. QUALITY ASSURANCE 1. By Miami-Dade County Department of Regulatory and Economic Resources. E. MATERIAL CERTIFICATIONS 1. None. Hitffiy A.Makar,P.E.,M.S. Product Control Unit Supervisor NOA No. 13-1010.09 Expiration Date: 10/10/2018 Approval Date: 05/08/2014 E-3 PART NAME:ICMG SKYLIGHT PLAN VIEW FILE NAME:H:\DWG\DWG\ACAD 2000 DRAWINGS\DADE COUNTY ICMG STI-00000290-SHT2 I SHEET 2 OF 2 DWG.NO.STI-00000290-SHT2 51.375 DESIGN PRESSURE RATING±80 PSF. slLlcorvE efioDlriG(corvrlNuos) DECO RING 0.050 6063 T•6 ALUhINIUM Max. MITERED AND WRAPAROUND LARGE MISSILE IMPACT RESISTANCE DECO CLIP 0.075 OUTBOARD GLASS SILICONE TOP AND BOTTOM OSB TEMPERED(116') OF POLYCARBONATE (CONTINUOS) I _ 10.84375 10.84375+ #Ba2xio0nYdnul 143WATEDAVi3PAM 8n 4.00-- Engineer of Record (7)per side M001649 FRLE0 +10.8437.5 -r +10,84375 - --I 4.00 `4.00 James D.Wells,Jr.,F.E. 0.125 X 2'ALUhINIUh1 FLAT BAR — — Professional Engineer No.53616 6063 T-6 BUTT WELDED CORNERS BTI.6 GLA68 INBOARD DSB GASKET TEMPERED(116') STI-205(0.060')MITERED AND WELDED CORNERS 723 J&L Wells Consulting LLC WOOD LINER ICMG 4949 I 1453 Arbitus Circle B12X2'PHILLIPS PAN HEAD SCREW .vTPO YCAnea'ATEWF.1 I Oviedo, Fl.32765 PADVJ.IPTLS°"°" SHErrIEIUTANOidLCn1 won #12 X 2 PHILLIPS P N/SCREW , (407)496-5489 pme Prxleaea 7 23 '12 x 1 112 closed cell PVC FASTENED SKYLIGHT ` Certificate of Authorization FLASHING BY OTHERS IN roa(5)PER SIDE ACCORDANCE WITH NRCA No7��2 311 /1 / BIOX2-112'DECKSCRESVLIGHT TUNNEL MA7ERIA1 #8-32 X 314 BOLT WI NUT ATTACHES7,23 ``N\50pVID W1/40 0/1 4'min (6)PER SIDE BBY OTHERS Y DADE COUNTY) FRAME TO ALUMINUM BAR ��� �1c EIV ae'✓p i�� roof surface to lip ROOFING FELT 61.375 (7)PER SIDE -I- _'� *" Max , _< No.53616 OG= sHINGLEs(1) 7.23 _ w^ 2X CURB HEIGHT TO BE SUFFICIENT TO '—0 I (Vti MAINTAIN 4'MINIMUM CLEARANCE DAYLIGHT OPENING % STA E OF �� BETWEEN ROOF SURFACE AND 45.5' 45.5" �i \ LOWEST LIP OF FRAh1E CURB (MAX)( ) (MAX( ) / •,�OR10'' �` _ SUPPLIED BY OTHERS(APPROVED BY CURB TO DECK FASTENERS 723 '' //�/ (A \``` ROOF DECK58'AtINIhtUlf BUTYL DADecourvTrl 1110 X 2.5' BUTYLSEALAtr 3-min ' prolruslon I 1 7.23 FASTENER SCHEDULE SKYLIGHT TO CURB FASTENER SCHEDULE CURB FASTENER SCHEDULE I #12 X 2"PHILLIPS PAN HEAD ATO DECK SUB-FRAME TO FRAME SCREWS #10 X 2-1/2"DECK SCREWS #8-32 BOLT w!NUT TP TO MODEL PER PER PER PER PER I �T TP LONG SIDE SHORT SIDE LONG SIDE SHORT SIDE LONG SIDE SHORT SIDE --5.93 4. O J 51.375 x 51.375 4949 5 5 8 8 7 7 Y 6.93-1 48.375 x 48.375 4646 5 5 8 8 7 7 35.375 x 51.375 3349 5 4 8 6 7 5 NO 4.00 35.375 x 35.375 3333 4 4 6 6 5 5 `(1)ALL ROOFING DETAILS SHALL COMPLY WITH PRDDUCTT;:1'iVIS90 32.375 x 32.375 3030 4 4 5 5 5 5 CHAPTER 15 OF THE 2010 FLORIDA BUILDING CODE COMPLU (2)4"MINIMUM DISTANCE FROM ANGLE LIP TO ROOF A�ldinge da 27.375 x51.375 2549 5 3 8 5 7 4 up1N1c0 No 3-/a 10,p9 27,375 x 35.375 2533 4 3 6 5 5 4 SURFACE IS FOR SHINGLE OR B.U.R.WITHOUT rarlr0)ionDr10 o /8 27.375 x 27.375 2525 3 3 5 5 4 4 INSULATION.FOR INSULATION AND TILE ROOF ADD BY s�� C 24,37--x 48.375 2246 5 3 6 3 7 a TILE HEIGHT AND INSULATION THICKNESS TO 4". MimnlDa ,uctCpnlntl 24.375x32.375 2230 4 3 5 3 5 4 (3)ANCHORS TO BE MADE FROM NON-CORROSIVE MATERIAL 24.375 x 24.375 11 222 3 3 3 3 4 4. COMPATIBLE WITH ALUMINUM. 19.375 x 51.3751 1749 5 3 8 3 7 3 (4)NO ONE-THIRD INCREASE IN THE DESIGN PRESSURE WAS USED. 19.375x35.375 1733 4 3 6 3 5 3 16.375,x 48.375 1 1446 5 2 8 3 1 7 3 16.375 x 32.375 1 1430 4 2 5 3 15 3 REVISION: REVISION: PRODUCT NAME: ICMG SUN-TEK MANUFACTURING, INC. BY: OnTE: BY: DATE: DRAWN BY: JW F DATE: 08/05/20111 DWG N0, STI-00000290-SHT2 REV. A 10303 GENERAL DRIVE ORLANDO,FL 32824 PART NAME:ICMG SKYLIG.. ASSEMBLY I FILE NAME:Z:\l; G\DWG\ACAD 2000 DRAWINGS\DADk COUNTY ICMG STI-00000290-SHT SHEET 1 OF EF DWG. STI-00000290-SHT1 DECO CLIP 0.075 6063 T-6 ALUMINUM 17132' SILICONE BEDDING OUTBOARD DSB ! GLASS BITE (CONTINUOUS) SILICONE TEMPERED SWIGGLE INSULATED TOP AND BOTTOM GLASS SPACER(CONTINUOUS) STI-214 DECO RING 0.050 MITRED OF POLYCARBONATE IAND WRAP AROUND (CONTINUOUS) J 6063 TT.6 AALUMN UM 1.55'WIDE X 1.18'HIGH INSULATED AIR SPACE INSULATED AIR SPACE pB-32 BOLT WI NUT ARGON GAS FILLED ARGON GAS FILLED (7)PER SIDE INBOADSB • ALUMINUM FLAT BX 2"6063TBAR CUT STI-205(0.069')MITERED AND STI-6 GLASS TEMPI D ALU WITH WELDED CORNERS WELDED CORNERS EPDM GASKET 2.45"WIDE x 3.93'HIGH I 6083 T-6 ALUMNIUM CONTINUOUS WOOD LINER STI 401- 1.16"WIDE X 0.935 HIGH 114" MAX. .177 POLYCARBONATE SHEET n+zx2°PHILLIPS PAN .177 PO CARBO AT HEAD SCREW(5)PER SIDE PAL PALSUIN OR SHEFFIELD MAKROLON GP OR 1.jrMIN. SABIC LEXAN 9034 EMBEDMENT 2X CURB HEIGHT TO BE . SUFFICIENT TO MAINTAIN 112 X 1 112 CLOSED CELL PVC 4'MINIMUM LOWEST POINT FOAM TAPE OF FRAME TO ROOF SURFACE SUPPLIED BY OTHERS LIGHT TUNNEL MATERIAL (APPROVED BY DADE COUNTY) #10X2-1/2"DECK SCREW BY OTHERS(APPROVED min 30° 4"MINIMUM ROOF BYDADECOUNTY) SURFACE TO LIP ROOFING FELT DESIGN PRESSURE RATING±80 PSF. FLASHING BY OTHERS IN LARGE MISSILE IMPACT RESISTANCE ACCORDANCE WITH NRCA SHINGLES (SEE NOTE 1) BUTYL SEALANT(CONTINOUS) Q A 5/B" IN. EMBEDMENT Engineer of Record NOTE: James D.Wells,Jr.,P.E. "min (1)ALL ROOFING DETAILS SHALL COMPLY WITH ROOF DECK Professional Engineer No.53616 Protrusion CHAPTER 15 OF THE 2010 FLORIDA BUILDING CODE 518'MINIMUM ���►lllllllf!!� (2)4"MINIMUM DISTANCE FROM ANGLE LIP TO ROOF SURFACE IS FOR OR B.U.R. ITHOUT J&L Wells Consulting LLC �� � v�E a�4s����i NSU ATION.FORSIN INSULATION AND TILE ROOF ADD w"mp3 06 WI RrVIt1110 FlonJn =* B"IIJinp Caja 1453 Arbitus Circle *� TILE HEIGHT AND INSULATION THICKNESS TO 4". AcccplonccNnt3-lo)o.pc� o.53616 (3)ANCHORS TO BE MADE FROM NON-CORROSIVE MATERIAL BxpirollunD Ic _ Oviedo,FI.32765 m= �° /g (407)496-5489 COMPATIBLE WITH ALUMINUM. o R1 T�bp{ �� (4)NO ONE-THIRD INCREASE IN THE DESIGN PRESSURE WAS USED. hf amlpnJ "ductco- Certificate of Authorization (5)TESTED TO TAS 201,TAS 202 AND TAS 203. No.27162 REVISION: Q 518'WAS 112'8 REVISION: OG NAME: REVISESHT.2OF2 ICMG SUN-TEK MANUFACTURING, INC. BY: 830 DATE: 08/07107 BY: DATE: DRAWN BY:JWF DATE: 05/03/201 DWG NO.STI-00000290-SHT1 REV. A 10303 GENERAL DRIVE ORLANDO,FL 32824