HomeMy WebLinkAboutNotice of Acceptance MIAMIMf;� MIAMI-DADE COUNTY
oDADE PRODUCT CONTROL SECTION
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES' ER
BOARD AND CODE ADMINISTRATION DIVISION ( 11805 SW 26 Street,Room 208
Miami,Florida 33175-2474
NOTICE OF ACCEPTANCE OA wwxv.miamidade.eovleconomv
Sun-Tek Manufacturing,Inc. ` '
10303 General Drive. �_ Q
Orlando,FL 32824 Jt�
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials.
The documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control
Section to be used in,Miami Dade County and other areas where allowed by the Authority Having Jurisdiction
(AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control
Section(In Miami Dade County)and/or the AHJ(in areas other than Miami Dade County)reserve the right to have
this product or material tested for quality assurance purposes. If this product or material fails to perform in the
accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke,
modify,or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke
this acceptance, if it is determined by Miami-Dade County Product Control Section that this product or material
fails to meet the requirements of the applicable building code.
This product'is approved as described herein, and has been designed to comply with the High Velocity Hurricane
Zone of the Florida Building Code.
DESCRIPTION: ICMG Skylight System
APPROVAL DOCUMENT: Drawing No. STI-00000290,titled"ICMG",sheet I &2 of 2,prepared by Sun-Tek
Manufacturing, Inc.,dated August 07,2007,with last revision"A"dated May 03,2012,signed and sealed by James
D.Wells,Jr., P.E.,bearing the Miami-Dade County Product Control Revision stamp with the Notice of Acceptance
number and the expiration date by the Miami-Dade County Product Control Section.
MISSILE IMPACT RATING: Large and Small Missile Impact Resistant
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo,city,state,model/series
and the following statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no
change in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials,use,and/or manufacture of the product or process.Misuse of this NOA as an endorsement of any product,
for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any
section of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami-Dade,County, Florida, and followed by
the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall
be done in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA revises&renews NOA#12-1011.16 and consists of this page 1,evidence submitted pages E-1,E-2, &
E-3 as well as approval document mentioned above.
The submitted documentation was reviewed by HyImy A.Makar,P.E.,M.S.
I NOA No. 13-1010.09
MIAMI•DADECOUNTYc. � - .�� ;� ��. Expiration Date: 10/10/2018
r Approval Dates 05/08/2014
o,5 Page 1
Sun-Tek Manufacturine,Inc.
NOTICE OF ACCEPTANCE:EVIDENCE SUBMITTED
1. EVIDENCE SUBMITTED UNDER PREVIOUS APPROVAL#07-0425.05
A. DRAWINGS
1. Drmving No. STI-00000290-SHTIISH72, titled "ICMG'; sheet I & 2 of 2,prepared by Stat-
Tek Mamifacturi»g, Inc, dated 06104107, with last revision dated 08107107, signed rnid sealed
by James D. Wells,Jr., P.E.
B. TESTS(submitted under NOA#02-0729.07)
1. Test Report on Large Missile Impact Test per PA 201, Cyclic Wind Pressure Test per
PA 203 and Uniform Static Air Pressure Test per PA 202 of "Model ICMG 4949
Insulated Glass Skylight with Polycarbonate Inner Liner" prepared by National
Certified Testing Laboratories, Report No. 210-2789-1, 2 & 3, dated 03/18/02, signed
and sealed by B.Portnoy, PE.
C. CALCULATIONS -
1. Anchor Calcidations for attachment of skylight to cubing and cm-bing to decking, dated
08/13/07, signed and sealed byJaines D. Wells,Jr., P.E.
D. MATERIAL CERTIFICATIONS(submitted under NOA#02-0729.07)
1. Die drawings No. STI-214 of Deco Ring, prepared by Sun-Tek Mant factturing, Inc, on
6/19/95.
2. Die drmving No. STI-205 of Curb Frame prepared by Sun-Tek Mantifacturing, Inc. on
12126/96.
E. STATEMENTS (submitted under NOA#02-0729.07)
1. Code coinpliance and No-Interest letter issued by Product Technology Corporation on
08127/02, signed and sealed by R.J. Quiroga PE.
F. OTHER
1. NOA renewal request letter isstied by Stin-Tek Manufacturing, Inc., dated 08116107,
signed by Jantes Feiidner.
2. EVIDENCE SUBMITTED UNDER PREVIOUS APPROVAL#11-0601.03
A. DRAWINGS
1. Drawing No. STI-00000290-SHTUSHT2, titled "]CMG", sheet I &2 of 2,prepared by
Stin-Tek Manufacturing, Inc., dated Atigiist 07, 2007, with last revision "A" dated
October 14, 2011, signed and sealed by James D. Wells, Jr., P.E.
4fWmy A.Makar,P.E.,M.S.
Product Control Unit Supervisor
NOA No. 13-1010.09
Expiration Date: 10/10/2018
Approval Date: 05/08/2014
E-1
Sun-Tek Manufacturing,Inc.
NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED
B. TESTS
1. Test Addendum for Test Report NCTL 210-2760-1, prepared by national Certified
Testing Laboratories, dated October 17, 2011, certifying the interlayer thickness,
signed by Mark Bennett, Manager of Testing Services(see NOA911-0601.02).
C. CALCULATIONS
1. None.
D. QUALITY ASSURANCE
1. By Miand-Dade Counfy Department of Permitting, Environment, and Regulatory
Affairs (PERA).
E. MATERIAL CERTIFICATIONS
1. None.
3. EVIDENCE SUBMITTED UNDER PREVIOUS APPROVAL#12-1011.16
A. DRAWINGS
1. Drmving No. STI-00000290, titled "ICMG", sheet I & 2 of 2, prepared by Sun-Tek
Manufacturing, Inc., dated August 07, 2007, with last revision "A" dated May 03,
2012, signed and sealed by James D. Wells, Jr., P.E.
B. TESTS
1. None.
C. CALCULATIONS
1. None.
D. QUALITY ASSURANCE
1. By Miami-Dade County Department of Regulalw y and Economic Resources.
E. MATERIAL CERTIFICATIONS
1. None.
F. OTHERS
1. A compliance letter, prepared by J& L Wells Consulting LLC, dated April 25, 2012,
certifying compliance with FBC 2010 edition, sign and sealed by James D. Wells, Jr.,
P.E.
2. Verification testing to be performed per letter from National Certified Testing
Laboratories, dated September 18, 2012, signed by Christopher Bennett.
lye y A.Makar,P.E.,M.S.
Product Control Unit Supervisor
NOA No. 13-1010.09
Expiration Date: 10/10/2018
Approval Date: 05/08/2014
E-2
z ,
Sun-Tek Manufacturing,Inc.
NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED
4. NEW EVIDENCE SUBMITTED
A. DRAWINGS
1. Drawing No. STI-00000290, titled "ICMG", sheet I & 2 of 2, prepared by Sun-Tek
Manufacturing, Inc., dated August 07, 2007, with last revision "A" dated May 03,
2012, signed and sealed by James D. Wells, Jr., P.E.
B. TESTS
1, Test Report on Large Missile Impact Test per PA 201, Cyclic Wind Pressure Test per
PA 203 and Uniform Static Air Pressure Test per PA 202 of "Model ICMG 4949
Insulated Glass Skylight with Polycarbonate Inner Liner" prepared by National
Certified Testing Laboratories, Report No. 210-3915-02, dated 09/13/13, signed and
sealed by Gerard J. Ferrara, P.E., on 09124/13.
2. Revised Test Report on Large Missile Impact Test per PA 201, Cyclic Wind Pressure
Test per PA 203 and Uniform Static Air Pressure Test per PA 202 of"Model ICMG
4949 Insulated Glass Skylight with Polycarbonate Inner Liner"prepared by National
Certified Testing Laboratories, Report No. 210-3915-02, dated 09/13113, revised on
02/26/14, signed and sealed by Gerard J. Ferrara, P.E., on 02128/14.
C. CALCULATIONS
1. Anchor Calculations for attachment of skylight to cubing and curbing to decking, dated
10/03/13, signed and sealed by James D. Wells, Jr„ P.E., on 10/03/13.
D. QUALITY ASSURANCE
1. By Miami-Dade County Department of Regulatory and Economic Resources.
E. MATERIAL CERTIFICATIONS
1. None.
Hitffiy A.Makar,P.E.,M.S.
Product Control Unit Supervisor
NOA No. 13-1010.09
Expiration Date: 10/10/2018
Approval Date: 05/08/2014
E-3
PART NAME:ICMG SKYLIGHT PLAN VIEW FILE NAME:H:\DWG\DWG\ACAD 2000 DRAWINGS\DADE COUNTY ICMG STI-00000290-SHT2 I SHEET 2 OF 2 DWG.NO.STI-00000290-SHT2
51.375 DESIGN PRESSURE RATING±80 PSF. slLlcorvE efioDlriG(corvrlNuos) DECO RING 0.050 6063 T•6 ALUhINIUM
Max. MITERED AND WRAPAROUND
LARGE MISSILE IMPACT RESISTANCE DECO CLIP 0.075
OUTBOARD GLASS
SILICONE TOP AND BOTTOM OSB TEMPERED(116')
OF POLYCARBONATE
(CONTINUOS) I
_ 10.84375 10.84375+ #Ba2xio0nYdnul 143WATEDAVi3PAM 8n
4.00-- Engineer of Record (7)per side M001649 FRLE0
+10.8437.5 -r +10,84375 - --I 4.00 `4.00 James D.Wells,Jr.,F.E.
0.125 X 2'ALUhINIUh1 FLAT BAR
— — Professional Engineer No.53616 6063 T-6 BUTT WELDED CORNERS BTI.6 GLA68 INBOARD DSB
GASKET TEMPERED(116')
STI-205(0.060')MITERED
AND WELDED CORNERS
723 J&L Wells Consulting LLC WOOD LINER
ICMG 4949 I 1453 Arbitus Circle B12X2'PHILLIPS PAN
HEAD SCREW .vTPO YCAnea'ATEWF.1
I
Oviedo, Fl.32765
PADVJ.IPTLS°"°"
SHErrIEIUTANOidLCn1 won
#12 X 2 PHILLIPS P N/SCREW , (407)496-5489 pme Prxleaea
7 23 '12 x 1 112 closed cell PVC
FASTENED SKYLIGHT ` Certificate of Authorization FLASHING BY OTHERS IN roa(5)PER SIDE ACCORDANCE WITH NRCA
No7��2 311 /1 / BIOX2-112'DECKSCRESVLIGHT TUNNEL MA7ERIA1
#8-32 X 314 BOLT WI NUT ATTACHES7,23 ``N\50pVID W1/40 0/1 4'min (6)PER SIDE BBY OTHERS Y DADE COUNTY)
FRAME TO ALUMINUM BAR ��� �1c EIV ae'✓p i�� roof surface to lip ROOFING FELT
61.375 (7)PER SIDE
-I- _'� *"
Max , _<
No.53616
OG= sHINGLEs(1)
7.23 _ w^ 2X CURB HEIGHT TO BE SUFFICIENT TO
'—0 I (Vti MAINTAIN 4'MINIMUM CLEARANCE
DAYLIGHT OPENING % STA E OF �� BETWEEN ROOF SURFACE AND
45.5' 45.5" �i \ LOWEST LIP OF FRAh1E CURB
(MAX)( ) (MAX( ) / •,�OR10'' �` _ SUPPLIED BY OTHERS(APPROVED BY
CURB TO DECK FASTENERS 723 '' //�/ (A \``` ROOF DECK58'AtINIhtUlf BUTYL DADecourvTrl
1110 X 2.5' BUTYLSEALAtr 3-min
' prolruslon
I 1 7.23 FASTENER SCHEDULE SKYLIGHT TO CURB FASTENER SCHEDULE CURB FASTENER SCHEDULE
I #12 X 2"PHILLIPS PAN HEAD ATO DECK SUB-FRAME TO FRAME
SCREWS #10 X 2-1/2"DECK SCREWS #8-32 BOLT w!NUT
TP TO MODEL PER PER PER PER PER
I
�T TP LONG SIDE SHORT SIDE LONG SIDE SHORT SIDE LONG SIDE SHORT SIDE
--5.93 4. O J 51.375 x 51.375 4949 5 5 8 8 7 7
Y 6.93-1 48.375 x 48.375 4646 5 5 8 8 7 7
35.375 x 51.375 3349 5 4 8 6 7 5
NO 4.00 35.375 x 35.375 3333 4 4 6 6 5 5
`(1)ALL ROOFING DETAILS SHALL COMPLY WITH PRDDUCTT;:1'iVIS90 32.375 x 32.375 3030 4 4 5 5 5 5
CHAPTER 15 OF THE 2010 FLORIDA BUILDING CODE COMPLU
(2)4"MINIMUM DISTANCE FROM ANGLE LIP TO ROOF A�ldinge da 27.375 x51.375 2549 5 3 8 5 7 4
up1N1c0 No 3-/a 10,p9 27,375 x 35.375 2533 4 3 6 5 5 4
SURFACE IS FOR SHINGLE OR B.U.R.WITHOUT rarlr0)ionDr10 o /8 27.375 x 27.375 2525 3 3 5 5 4 4
INSULATION.FOR INSULATION AND TILE ROOF ADD BY s�� C 24,37--x 48.375 2246 5 3 6 3 7 a
TILE HEIGHT AND INSULATION THICKNESS TO 4". MimnlDa ,uctCpnlntl 24.375x32.375 2230 4 3 5 3 5 4
(3)ANCHORS TO BE MADE FROM NON-CORROSIVE MATERIAL 24.375 x 24.375 11 222 3 3 3 3 4 4.
COMPATIBLE WITH ALUMINUM. 19.375 x 51.3751 1749 5 3 8 3 7 3
(4)NO ONE-THIRD INCREASE IN THE DESIGN PRESSURE WAS USED. 19.375x35.375 1733 4 3 6 3 5 3
16.375,x 48.375 1 1446 5 2 8 3 1 7 3
16.375 x 32.375 1 1430 4 2 5 3 15 3
REVISION: REVISION: PRODUCT NAME: ICMG SUN-TEK MANUFACTURING, INC.
BY: OnTE: BY: DATE: DRAWN BY: JW F DATE: 08/05/20111 DWG N0, STI-00000290-SHT2 REV. A 10303 GENERAL DRIVE ORLANDO,FL 32824
PART NAME:ICMG SKYLIG.. ASSEMBLY I FILE NAME:Z:\l; G\DWG\ACAD 2000 DRAWINGS\DADk COUNTY ICMG STI-00000290-SHT SHEET 1 OF EF DWG. STI-00000290-SHT1
DECO CLIP 0.075
6063 T-6 ALUMINUM
17132' SILICONE BEDDING
OUTBOARD DSB ! GLASS BITE (CONTINUOUS)
SILICONE TEMPERED SWIGGLE INSULATED
TOP AND BOTTOM GLASS SPACER(CONTINUOUS) STI-214 DECO RING 0.050 MITRED
OF POLYCARBONATE IAND
WRAP AROUND
(CONTINUOUS) J 6063 TT.6 AALUMN UM 1.55'WIDE X 1.18'HIGH
INSULATED AIR SPACE INSULATED AIR SPACE pB-32 BOLT WI NUT
ARGON GAS FILLED ARGON GAS FILLED (7)PER SIDE
INBOADSB • ALUMINUM FLAT BX 2"6063TBAR CUT
STI-205(0.069')MITERED AND STI-6 GLASS TEMPI D ALU
WITH WELDED CORNERS
WELDED CORNERS EPDM GASKET
2.45"WIDE x 3.93'HIGH I
6083 T-6 ALUMNIUM
CONTINUOUS WOOD LINER STI 401-
1.16"WIDE X 0.935 HIGH 114"
MAX.
.177 POLYCARBONATE SHEET n+zx2°PHILLIPS PAN
.177 PO CARBO AT HEAD SCREW(5)PER SIDE
PAL
PALSUIN
OR
SHEFFIELD MAKROLON GP OR
1.jrMIN.
SABIC LEXAN 9034 EMBEDMENT
2X CURB HEIGHT TO BE .
SUFFICIENT TO MAINTAIN
112 X 1 112 CLOSED CELL PVC 4'MINIMUM LOWEST POINT
FOAM TAPE OF FRAME TO ROOF SURFACE
SUPPLIED BY OTHERS
LIGHT TUNNEL MATERIAL (APPROVED BY DADE COUNTY)
#10X2-1/2"DECK SCREW BY OTHERS(APPROVED min 30°
4"MINIMUM ROOF BYDADECOUNTY)
SURFACE TO LIP ROOFING FELT
DESIGN PRESSURE RATING±80 PSF. FLASHING BY OTHERS IN
LARGE MISSILE IMPACT RESISTANCE ACCORDANCE WITH NRCA
SHINGLES
(SEE NOTE 1) BUTYL
SEALANT(CONTINOUS) Q
A
5/B" IN.
EMBEDMENT
Engineer of Record NOTE:
James D.Wells,Jr.,P.E. "min (1)ALL ROOFING DETAILS SHALL COMPLY WITH ROOF DECK
Professional Engineer No.53616 Protrusion CHAPTER 15 OF THE 2010 FLORIDA BUILDING CODE 518'MINIMUM
���►lllllllf!!� (2)4"MINIMUM DISTANCE FROM ANGLE LIP TO ROOF
SURFACE IS FOR OR B.U.R.
ITHOUT
J&L Wells Consulting LLC �� � v�E a�4s����i NSU ATION.FORSIN INSULATION AND TILE ROOF ADD w"mp3 06 WI RrVIt1110 FlonJn
=* B"IIJinp Caja
1453 Arbitus Circle *� TILE HEIGHT AND INSULATION THICKNESS TO 4". AcccplonccNnt3-lo)o.pc�
o.53616 (3)ANCHORS TO BE MADE FROM NON-CORROSIVE MATERIAL BxpirollunD Ic _
Oviedo,FI.32765 m= �° /g
(407)496-5489 COMPATIBLE WITH ALUMINUM. o
R1 T�bp{ �� (4)NO ONE-THIRD INCREASE IN THE DESIGN PRESSURE WAS USED. hf amlpnJ "ductco-
Certificate of Authorization (5)TESTED TO TAS 201,TAS 202 AND TAS 203.
No.27162
REVISION: Q 518'WAS 112'8 REVISION: OG NAME:
REVISESHT.2OF2 ICMG SUN-TEK MANUFACTURING, INC.
BY: 830 DATE: 08/07107 BY: DATE: DRAWN BY:JWF DATE: 05/03/201 DWG NO.STI-00000290-SHT1 REV. A 10303 GENERAL DRIVE ORLANDO,FL 32824