Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Quinteros CD_ permit sheets_11-6-20_ signed
GSPublisherVersion 0.0.100.100 ............................. .. .. .. .. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . F F LOO E RTI DAT AS R T E C G EISTITHERCER D A AR97108 QU I N T E R O S RE S I D E N C E NE W SI N G L E FA M I L Y RE S I D E N C E 46 3 7 S . He a d e r Ca n a l Rd , Fo r t Pi e r c e , FL 34 9 4 5 A-1 floor plan 9/14/20 ID DA T E CO M M E N T FL De s i g n Bu i l d In s p e c t Co n s t r u c t i o n + Ar c h i t e c t u r e + Ho m e In s p e c t i o n CR C 13 3 1 2 6 3 | AA 26 0 0 3 1 4 2 | HI 10 7 7 6 77 2 .32 1 .45 0 0 fr a n k .li e b l e r @ gm a i l .co m ww w .FL D e s i g n B u l i d I n s p e c t .co m © AL L ID E A S , DE S I G N S , PL A N S AN D AR R A N G E M E N T S IN D I C A T E D ON TH I S SH E E T AR E TH E PR O P E R T Y OF FL DE S I G N BU I L D IN S P E C T , AN D WE R E CR E A T E D , EV O L V E D AN D DE V E L O P E D FO R TH I S SP E C I F I C PR O J E C T . S H E E T 2 -4 x 6 -8 2 -8 x 6 -8 2 -8 x 6 -8 3-0x6-8 6-0x6-8 2 -4 x 6 -8 2-8x6-8 2 -4 x 6 -8 3 -0 x 6 -8 2 -8 x 6 -8 2-8x6-8 2-8x6-8 2 -8 x 6 -8 2 -4 x 6 -8 2-8x6-8 2 -4 x 6 -8 2-4x6-8 2 -8 x 6 -8 DRWA 2' 37 ' 18 ' 6' - 8 " 22'33'-4"29' 2' 36 ' - 4 " 25 ' - 4 " 4'9'-8"8' 13'-9 1/2" 6' 12'-8" 8' 12'-8" 24'-7" 11 ' - 3 1/ 2 " 5' 12 ' - 1 " 6' 9'-8" 3'-9" 9"20'-2"4 1/2"13'-1/2" 24'4'4'2'-1" 10 ' - 1 1/ 2 " 3' - 6 " 18 ' - 5 1/ 2 " 8' 42'-4"13' 10 ' 12'-3 1/2" 3'-10 1/2" 10' 13'-2 1/4" 7' - 6 " 15 ' - 1 1 " 13'-11" 13'-2 1/2" 3' - 2 " 10 ' - 6 " 9' - 5 " 4'-3 1/2" 6'-6" 15 ' 8' 2' - 8 " 8'9'-8"8'-4" 10 ' 3' - 7 1/ 2 " 4' - 3 1/ 2 " 2' - 6 " 8' 3'2'-8"4' 9" 6' - 2 1/ 2 " 6' - 2 1/ 2 " 3' - 6 " 1'-2 3/4"2'5'-4"2'12'-2 3/4"2'5'-4"2'1'-2 3/4" 5'-3 1/4" 7'-1/4" 2' 1' - 2 " 2' - 5 1/ 2 " 5' 2' 2'10'-9 1/2"2' 2' 3'-4" 14 ' - 1 1 " 6"20'-4"12'-6"7'-8 1/2" 9' - 5 1/ 2 " 1' - 8 " 16 ' 1' - 4 " 16 ' 1' - 4 " 5' - 4 " 3'-6" 8'-9 1/2" 1 3 1 2 2 4 3 57 6 7 SK SW R TU B SKSWR SK SW R SK 30 " CT & HO O D LIVING UTILITY CLST BR.3 DENBR.2 M.BR GARAGE REAR PORCH FRONT PORCH 30 " OV SK SK GAME ROOM AH U HW H HB HB HB HB D1 D2 D3 D 4 D 5 D 6 W1 W 2W 4 W3 W 7 W 5 W6 W8 W 9 W10 W 1 1 W12 W13 W 1 4 BA.1 BA.2 BA.3 DW REF 36Wx33D CU WALL LEGEND REINFORCED CMU WALL W/ FINISHES NON LOAD BEARING INT WALL DESCRPTIONID SPECS SEE TYP WALL SECTION REINFORCED CMU COLUMN SEE FLOOR PLAN SEE GENERAL SPECIFICATIONS ON A-1 SEE BRG WALL DETAILLOAD BEARING 2x4 WALL THICKNESS ON FLOOR PLAN 9" VARIES 4.5" 4.5" SEE TYP WALL SECTIONREINFORCED CMU WALL WO/ INT FINISH 8"conditioned living area 2,813 sf garage 941 sf covered rear porch 496 sf covered front porch 267 sf total building area 4,517 sf conditioned volume 23,554 cf 6" MI N H SEE ELEVS W W 2' H 8" 8" FOOTING PER FOUNDATION PLAN & FOOTING SCHEDLE- REINF PER FOOTING SCHEDULE GRADE AS PER SITE PLAN SOG/FILL/COMPCTION PER FOUNDATON PLAN AND GEN NOTE 17 PE TRUSS AS PER FRAMING PLANS- INSULATION AS PER GENERAL SPECS METAL DRIP OVER PT WOOD DRIP OVER 2x6 CEDAR FASCIA TO TRUSS ENDS W/ (2) #16d NAIL, 4" TRUSS HEEL SLOPE AS PER ELEV SEE FRAMING PLANS OR CONNECTOR SCHEDULE LINTELS PER DOOR/WINDOW/LINTEL SCHEDULE STUCCO OVER 8x8x16 CMU W/ #5 VERT REBAR @ 48" OC W/ CONT CMU BOND BEAM TOP (2) COURSES W/ #5 REBAR EA COURSE- 1/2" OR 5/8" GWB OVER OVER 3/4" FURRING STRIP. GARAGE WALLS TO BE UNINSULATED & UNFINISHED. WALL REINF AS PER GEN NOTE 16.8. DOWELS PER GEN NOTE 17.2 METAL OVER PEEL & STICK OVER 5/8" CDX PLY OVER PE WOOD ROOF TRUSS AS PER FRAMING PLAN. OPTIONAL CJ/EJ OPTIONAL CJ/EJ HOUSEGARAGE 1/2" OR 5/8" GWB OVER WOOD PE TRUSS BC. STUCCO & LATH PER GEN NOTE 34 OVER FRAMING W/ NO VENTS. GENERAL SPECS: A-1 GENERAL NOTES: GN-1 MONO @ CURB/ RECESS MONO @ STEP F6 H ID ACTUAL D. PRESSURES W H LINTEL DESCRIPTION D1 34.1, ‐36.1 6‐0 6‐8 CC 8RF14‐1B/1T D. SWING, GLAZED D2 34.1, ‐36.1 8‐0 6‐8 CC 8RF16‐1B/1T 2 PANEL SGD D3 34.1, ‐36.1 12‐0 6‐8 CC 8RF16‐1B/2T 3 PANEL SGD D4 34.1, ‐36.1 6‐0 6‐8 CC 8RF14‐1B/1T D. SWING, GLAZED D5 30.1, ‐33.5 16‐0 7‐0 CC 8RF16‐1B/1T SECTIONAL OVERHEAD D6 30.1, ‐33.5 16‐0 7‐0 CC 8RF16‐1B/1T SECTIONAL OVERHEAD DOOR/ LINTEL SCHEDULE SEE GEN NOTE 26. CC: CAST CRETE. ID ACTUAL D. PRESSURES W H B.O. LINTEL LINTEL TYPE NOTES W1 35.7, ‐38.7 3‐11 5‐1 6‐8 CC 8F16‐1B/1T S.HUNG W2 35.7, ‐38.7 1‐4 5‐1 6‐8 CC 8F16‐1B/1T S.HUNG W3 35.7, ‐38.7 3‐11 5‐1 6‐8 CC 8F16‐1B/1T S.HUNG EGRESS W4 35.7, ‐38.7 1‐4 5‐1 6‐8 CC 8F16‐1B/1T S.HUNG W5 35.7, ‐38.7 1‐4 5‐1 6‐8 CC 8F16‐1B/1T S.HUNG W6 35.7, ‐38.7 3‐11 5‐1 6‐8 CC 8F16‐1B/1T S.HUNG EGRESS W7 35.7, ‐38.7 1‐4 5‐1 6‐8 CC 8F16‐1B/1T S.HUNG W8 35.7, ‐38.7 3‐11 5‐1 6‐8 CC 8F16‐1B/1T S.HUNG EGRESS W9 35.7, ‐38.7 2‐11 1‐3 6‐8 CC 8F16‐1B/1T FIXED TEMP W10 35.7, ‐38.7 4‐3 5‐1 6‐8 CC 8F16‐1B/1T FIXED W11 35.7, ‐38.7 4‐3 5‐1 6‐8 CC 8F16‐1B/1T FIXED W12 35.7, ‐38.7 7‐11 5‐1 6‐8 CC 8F16‐1B/1T FIXED W13 35.7, ‐38.7 5‐11 1‐3 6‐8 CC 8F16‐1B/1T FIXED W14 35.7, ‐38.7 3‐11 1‐3 6‐8 8"x16" (2) #5 T/B, #3 TIE @ 6" OC FIXED TEMP WINDOW/ LINTEL SCHEDULE SEE GEN NOTE 26. CC: CAST CRETE. A-1 A-2 A-3 A-4 GN-1 floor plan foundation plan elevs elect general notes FLOOR PLAN- DIMENSIONED SCALE: 1/4"= 1'-0" TYP WALL SECTION SCALE: 1/2"= 1'-0" SHEET INDEX 1 1 FLOOR PLAN NOTES: 1. INTERIOR DIMENSIONS ARE TO FINISH. SEE WALL LEGEND FOR THICKNESS. 2. EXTERIOR DIMENSIONS ARE TO STRUCTURE. FLOOR PLAN KEYNOTES: 1. PEAK OF 3/12 VAULTED CEILING 2. FAUX BEAMS @ BOTTOM OF VAULT 3. 1'H TRAY CLG 4. 22"x30" RO MIN ATTIC ACCESS 5. TYP REAR PORCH BEAM- CAST CRETE 8F16-1B/2T. 8' TOB. 5. TYP FRONT PORCH BEAM- CAST CRETE 8F12-1B/2T. 8' TOB. 7. TYP PORCH COLUMN- 12"x12"x8" CMU, 4 #5 VERT, #3 TIE @ 16" OC. GENERAL SPECIFICATIONS: 1. INTERIOR NON LOADBEARING WALLS: 1/2" OR 5/8" GWB OVER 3-5/8" 25 GA METAL STUD OR 2x4 @ 16" OC. 2. PORCH CEILING: STUCCO & LATH OVER FRAMING OR PINE T&G PER GEN NOTE 34. 3. INSULATION: EXT WALLS: R4.1 FOIL INSULATION. R20 SPRAYFOAM @ CONDITINED ROOF DECK, & ATTIC SEPARATING KNEE WALLS @ PORCHES & GARAGES. R-13 BATT @ GARAGE SEPARATING WALL, FLOOR TO CLG. PROVIDE ACCESS HATCH TO CONNECT ATTIC SPACES. 4. DEFFERED SUBMITTALS: ROOF TRUSSES, SITE PLAN, DUCT LAYOUT, FOUNDATION PLAN 1 11 /6 /20 cl i e n t re v PROJECT DESCRIPTION NEW 1 STORY SF RESIDENCE. ZONING INFORMATION: parcel id: 3202-500-0007-000-3 AG-5 (unincorporated St Lucie County) flood zone: X UTILITY INFORMATION: gas: n/a sewage: septic potable water: well AREA CALCULATIONS : DocuSign Envelope ID: F4209D74-134B-4A0B-83A8-512AEE762AE1 11/6/2020 GSPublisherVersion 0.0.100.100 ............................. .. .. .. .. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . F F LOO E RTI DAT AS R T E C G EISTITHERCER D A AR97108 QU I N T E R O S RE S I D E N C E NE W SI N G L E FA M I L Y RE S I D E N C E 46 3 7 S . He a d e r Ca n a l Rd , Fo r t Pi e r c e , FL 34 9 4 5 A-4 elect 9/14/20 ID DA T E CO M M E N T FL De s i g n Bu i l d In s p e c t Co n s t r u c t i o n + Ar c h i t e c t u r e + Ho m e In s p e c t i o n CR C 13 3 1 2 6 3 | AA 26 0 0 3 1 4 2 | HI 10 7 7 6 77 2 .32 1 .45 0 0 fr a n k .li e b l e r @ gm a i l .co m ww w .FL D e s i g n B u l i d I n s p e c t .co m © AL L ID E A S , DE S I G N S , PL A N S AN D AR R A N G E M E N T S IN D I C A T E D ON TH I S SH E E T AR E TH E PR O P E R T Y OF FL DE S I G N BU I L D IN S P E C T , AN D WE R E CR E A T E D , EV O L V E D AN D DE V E L O P E D FO R TH I S SP E C I F I C PR O J E C T . S H E E T ELECTRICAL RISER DIAGRAM SCALE: N.T.S. 6' MIN. WIRE SIZE BY ELECTRICAL CONTRACTOR NEW METER GEC TO CWP, UFER, INTERSYSTEM NEW UNDERGROUND SERVICE ne w pa n e l B 20 0 A ML O ne w pa n e l A 20 0 A MC B 220.12 2813 ft2 8,439 va ft2 - va 220.52(A) 2 x 1500 va =3,000 va 220.52(B) Laundry Load 1 x 1500 va =1,500 va 12,939 va 220.42 Lighting Load Feeder Demand Factors First 3000 or less at 100%3,000 va From 3001 to 120,000 at 35%3,479 va Remainder over 120,000 at 25%- va 6,479 va 220.54 Electric Clothes Dryers Qty 1 Electric Dryer #1 5.00 kw 5,000 w Qty 0 Electric Dryer #2 ‐ kw - w 220.55 Electric Cooking-Ranges, Stove Tops and Wall Ovens Qty 1 8.00 kw Qty 0 8.00 kw Qty 0 ‐ kw 6,400 w 220.51 Fixed Electric Space Heating Loads or Air Conditioning Load: 10.0 kw AC#1/Geo 16 SEER 5 Ton 5.7 kva ‐ kw AC#2/Geo - kva ‐ kw AC#3/Geo - kva ‐ kw AC#4/Geo - kva ‐ kw AC#5/Geo - kva 15,716 va 220.14 Appliance load--Dwelling Units Qty va(watts) Qty va(watts) 1 300 0 ‐ 1 1,200 0 ‐ 1 1,440 0 ‐ 1 1,580 0 ‐ 0 ‐ 0 ‐ 0 ‐ 0 ‐ 0 ‐ 0 ‐ 4,520 va 220.53 Appliance load--Dwelling Units 3,390 va 220.50 Motor Loads @ 120 Volts Qty va(watts) Qty va(watts) 2 563 0 ‐ 1 375 0 ‐ 2 375 0 ‐ 0 ‐ 0 ‐ 2,251 va 430.24 Several Motors or a Motor(s) and Other Load(s) 141 va 2,392 va 39,377 va 164 amps NEW AMPS 200 AMPS CHOOSEVICE SIZE REQUESTED = 200 amps Note: Electrical contractor to verify accuracy and completeness of load calculation. HVAC specs are esitimates only. MINIMUM SERVICE SIZE EXISTING SERVICE SIZE TOTAL CALCULATED DEMAND LOAD in AMPS @120/240V 1ph3W = TOTAL CALCULATED DEMAND LOAD in Volt-amperes = 3/4hpPool/Spa Pump Total Motor Load = 25% of Largest Motor Load = Total Motor Demand Load = 1/2hpGarbage Disposal 1/2hpGar/DoorOpener Total Connected Appliance Load = Total Appliance Demand Load = Description Description Microwave Water Heater Dishwasher Refrigerator Description Description Fixed Electric Space Heat #1 Fixed Electric Space Heat #2 Fixed Electric Space Heat #3 Fixed Electric Space Heat #4 Fixed Electric Space Heat #5 Electric Cooktop Nameplate Wall Oven Nameplate Electric Cooking Demand Load= Total Heat & AC Load = # of Small Appliance Branch Circuits = # of Laundry Branch Circuits = Total General Lighting & Appliance Load= Total Lighting Demand Load= 1500 va for each 20 amp branch circuit required per 210.1(C)(1) in EACH kitchen, pantry, breakfast room, dining room, or similar areas. Electric Load Calculation General Lighting Load 3 va/ft2 of floor area, including unused space adaptable for future use. Floor Area = Basement Floor Area = Small Appliance Load DRWA SK TU B SK SK SK 30 " CT & HO O D 30 " OV SK SK FRONT E4 KITCHEN L1 MD MD MD MD MD MD MD MD AH U HW H KITCHEN L1 ATTIC LT YARD LT DW REF 36Wx33D CU E -WA E -DR E- CU E ME T E R E-REF L1 L1L2 E4 E4 E5 DB L2 S S S FL S S L1 L1L1 L1 L1L1 S S S SS E3 SS L7 L7 L7 S S S L2 L1 L1 L1 L1 L1 L2 S E1 E1 E 1 L1 L1 L1 L1 L1 L1 L1 L1 S L2 S SS L 9 L 9 L4 EXL S S L2 SE1 L 4 L12 L1 L1 EX E2 S S S FL FL L2 L2 S S S S SS E1 E1 L2 SE1 E 2 E2 E2 L2 S S S FL L1 L1 L1 L1 S E 3 S L4 L4 L12 L12 L2 EXL S E 2 E2 E2 E 2 S S S L2 L1 L1 L1 L1 SS E1 FA FA L1 L1 L1 L1 L1 L1 L1 E5 E 5 E 5 L2 L2 L2 L2 S E - OH DO O R E - OH DO O R PANEL B E -RE F E-ICE E-RGE-HOOD L9 L9 L9 E-HWH E 2 E 2 SS E2 E2 E2 E 2 E 2 E6 CO N D U I T TO (2 ) PO N D PU M P S E-H2OPUMP L11L11 L11 L11L11 S E-GD (2)E-OV E-DW E-MW E2 E2 E2 E2 E 2 E1 E 1 E 1 E1E1 E 1 E 1 E1 E1 E1 E 1 E 1 E1 E1 E 1 E1 E1 E1 E1 E 1 E1 E 1E1 E1 E1 E1 E1 E 1 E1 E1 E 1 E1 E1 E 1 E 1 E1 E 1 E 1 S E 1 E 1 E1 E1 L1 L1 L1 L1S L1 L1L1 S L1 L1 L1 S L2 S SE2 E7 S S E-AHU CA B L E BO X L1 E5 SD SD SD SD SD ELECT PLAN LEGEND E1 E2 E3 E4 E5 E6 E7 E- L1 L2 L3 L4 L5 L6 L7 L8 L9 L10 L11 L12 S EX EXL FL FA JB SD TV 120V DUPLEX RECEPTACLE 120V GFCI DUPLEX RECEPTACLE 120V RECEPTACLE recessed for tv, w/ tv cable 120V GFCI DUPLEX RECEPTACLE- @ soffit 120V GFCI DUPLEX RECEPTACLE w/ water protected box 240V RECEPTACLE- gene backfeed w/ panel lockout 120V RECEPTACLE- floor fv w/ owner ELECTRIC FOR LABLED APPLIANCE RECESSED CAN LIGHT FLUSH MOUNT CLG LIGHT FLUSH LED STRIP LIGHT VANITY WALL LIGHT SHOP LIGHT CHANDELIER LIGHT PENDANT LIGHT UNDER CABINET LIGHT EXTERIOR WALL SCONCE WALL MOUNT READING LIGHT EXTERIOR MOTION DETECTOR LIGHT W/ CAMERA RECESSED CAN LIGHT- wet location LIGHT SWITCH EXHAUST FAN- vent to roof if vented soffit, soffit if unvented EXHAUST FAN WITH LIGHT- vent to roof if vented soffit, soffit if unvented FAN/ LIGHT COMBO FAN W/O LIGHT JUNCTION BOX SMOKE/CO2 DETECTOR- interconnected, hardwired w/battery TELEVISION CABLE ITEM TYPE ID 1 BUILDING DP 2 PRODUCT DP GLASS TYPE 5 MFR MODEL APPROVAL # FASTNERS 6 DOOR OVERHEAD ALL 36,‐42 N/A Clopay any FL 16546.4 DOOR D. SWING, GLAZED ALL 50,‐50 IMPACT Plastpro any FL 17184.2 DOOR D. SWING, GLAZED ALL 50,‐50 IMPACT Therma Tru L FL 20468.12 DOOR SGD ALL 46,‐60 IMPACT PGT SGD‐770 NOA 19‐1126.03 WINDOW S. HUNG ALL 65,‐70 IMPACT PGT SH‐5500 NOA 20‐0401.03 WINDOW FIXED ALL 50,‐50 IMPACT PGT PW‐5520 NOA 19‐1126.10 WINDOW MULLION ALL 79.6 N/A PGT 1.25"x3.25"x.100" NOA 17‐0630.01 ROOFING UNDERLAYMENT ALL N/A N/A N/A Polystick MTS FL 5259.1 ROOFING METAL ALL ‐34.8 field, ‐ 83.9 edge ‐69.2 field, ‐ 129. edge N/A JA Taylor 5v crimp FL 17443 screw @ 12" oc trans, 16" oc longitudial/ 3" end FRANK LIEBLER, ARCHITECT (AR97108) PRODUCT APPROVAL AFFIDAVIT 1. 'ID' as per door & window schedule, or all meaning worst case of all similar items of that type. 2. If building dp are left blank‐ see door & window schedule or design pressure chart. 3. This affidavit is only to verify product's compliance with wind loads. 4. Unless products are specifically submitted for verification by contractor, they are assumed. 5. If glass type is not specified more than 'impact', may use any of the impact glass type in the install instructions to achieve the stated building design pressures. 6. If fasteners is left blank, may use any of the specified attachment methods in the install instruction matching structure provided to achieve the stated building design pressures. 7. I have reviewed the above components or cladding and I have approved their use in this structure. These products provide adequate resistance to the wind loads and forces specified by current code provisions. ATTIC ID AREA RATIO AREA REQ MIN QTY OF 8x16 SOFFIT VENTS PERIMETER MAX SPACING REAR PORCH 496 SF 150 476 SI 4 51 LF 13 LF FRONT PORCH 267 SF 150 256 SI 3 44 LF 15 LF GARAGE 941 SF 150 903 SI 8 66 LF 8 LF ATTIC VENTILATION CALC WA SK TU B SK SK SK SK SKWA 2", VTR 2" SK 1.5"SK 1.5" SK 1.5" 1.5" VTR 2" VTR WC 3" TUB 2"SWR 2" SK 1.5" AAV CO CO 4" 4" 2" VTR SK 1.5" WC 3" SWR 2" WC 3"SK 1.5" 2" VTR ELECT PLAN SCALE: 3/16"= 1'-0" PLUMBING DIAGRAM SCALE: 1/8"= 1'-0" 1 1 ELECT PLAN NOTES: 1. SEE GENERAL NOTES 27 ON GN-1. 2. GFI PER PLAN & GEN NOTE 27.4. INCLUDING ALL RECEPTACLES IN LAUNDRY ROOM, WASHER, DISHWASHER, GARAGE DOOR OPENER. 3. PROVIDE DISCONNECTS FOR WATER HEATER, CU, AHU 4. ALL 120 VOLT BRANCH CIRCUITS SUPPLYING RECEPTACLES INSTALLED IN FAMILY ROOMS, DINING ROOMS, LIVING ROOMS, PARLORS, LIBRARIES, DENS, BEDROOMS, SUNROOMS, RECREATION ROOMS, CLOSETS, HALLWAYS, OR SIMILAR ROOMS OR AREAS SHALL BE PROTECTED BY A LISTED ARC-FAULT CIRCUIT INTERRUPTER , COMBINATION-TYPE, INSTALLED TO PROVIDE PROTECTION OF THE BRANCH CIRCUIT (NEC 210.12(B)). PLUMBING DIAGRAM NOTES: 1. AIR ADMITANCE VALVES (AAV) MAY BE USED IN LIEU OF VTR AS LONG AS ONE 2" VTR REMAINS. 1 11 /6 /20 cl i e n t re v DocuSign Envelope ID: F4209D74-134B-4A0B-83A8-512AEE762AE1 11/6/2020