HomeMy WebLinkAboutRevisions; Energy CodesOFFICE USE ONLY:
DATE FILED: /
REVISION FEE: • i%
PERMIT # 196G — CQ / -2S-
RECEIPT #
PLANNING & DEVELOPMENT SERVICES
BUILDING & CODE REGULATION DIVISION
23.00 VIRGINIA AVENUE
FORT PIERCE, FL 34982.5652
(772) 462-1553
APPLICATION FOR BUILDING PER
REV
PROJECT INFORMATION ISION
LOCATION/SITE
ADDRESS:
DETAILED DESCRIPTION OF PROJECT
REVISIONS:
CONTRACTOR INFORMATION:
STATE of FL REG./CERT. #: ST. LUCIE CO CERT. #:
BUSINESS NAME:
QUALIFIERS NAME:
ADDRESS:
CITY: STATE: ZIP:
PHONE (DAYTIME): FAX:
OWNERBUILDER INFORMATION:
NAME: L .J Y AJ A/
ADDRESS: S-000 u S �
CITY: STATE: ZIP: 3' V 9Z
PHONE (DAYTIME: _ Z ay y 3 FAX:
ARCHITECT/ENGINEER INFORMATION:
NAME:
ADDRESS:
CITY:
PHONE (DAYTIME):
SLCCC: 9123109
Revised 06130/17
STATE:
FAX:
ZIP:
SEP g 2019
Permitting Department
St. Lucie Clounty, FL
FORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: WYNNE THE WINDSOR 64
Builder Name: WYNNE DEVELOPMENT
Street: 64 MED EAST
Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE, FL,
Permit Number:1906-0175
Owner:
Jurisdiction:
Design Location: FL, Fort Pierce
County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing New (From Plans)
9. Wall Types (1432.0 sqft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Ext Insul, Exterior
R=4.1 1224.00 ftZ
b. Frame - Wood, Adjacent
R=11.0 208.00 ftZ
3. Number of units, if multiple family 1
c. N/A
R= ftz
4. Number of Bedrooms 3
d. N/A
R= ftZ
5. Is this a worst case? No
10. Ceiling Types (1753.0 sqft.)
Insulation Area
a. Under Attic (Vented)
R=30.0 1753.00 ft Z
6. Conditioned floor area above grade (ftZ) 1753
b. N/A
R= ftz
Conditioned floor area below grade (ftZ) 0
c. N/A
R= ftZ
11. Ducts
R ftZ
7. Windows(151.4 sqft.) Description Area
a. Sup: Attic, Ret: Attic, AH: Attic
6 245
a. U-Factor: Sgl, U=1.04 111.36 ftZ
SHGC: SHGC=0.29
b. U-Factor: Sgl, U=1.11 40.00 ftZ
12. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.27
a. Central Unit
34.8 SEER:15.00
c. U-Factor: N/A ftZ
SHGC:
13. Heating systems
kBtu/hr Efficiency
d. U-Factor: N/A ftZ
a. Electric Heat Pump
34.8 HSPF:8.50
SHGC:
Area Weighted Average Overhang Depth: 2.850 ft.
Area Weighted Average SHGC: 0.285
14. Hot water systems
a. Electric
Cap: 40 gallons
8. Floor Types (1753.0 sqft.) Insulation Area
EF: 0.970
a. Slab -On -Grade Edge Insulation R=0.0 1753.00 ftZ
b. Conservation features
b. N/A R= ftZ
None
c. N/A R= ftZ
15. Credits
Pstat
Glass/Floor Area: 0.086 Total Proposed Modified Loads: 52.08
PASS
Total Baseline Loads: 53.86
I hereby certify that the plans and specifications covered by
Review of the plans and
ST.q?A
this calculation are in compliance with the Florida Energy
specifications covered by this
kgaTHE
�y _ O
Code.
calculation indicates compliance
",�
with the Florida Energy Code.
�+ uk,''% :°�. O
PREPAR B :
Before construction is completed
DATE:
this building will be inspected for
compliance with Section 553.908
I hereby certify that this building, as designed, is in compliance
Florida Statutes.
5�
with the Florida Energy Code.
q
C�
QWNER/AGEN
�
B F L: T
[SATE: a 2 - oe
DATE:
Compliance requires certification by the air handier unit manufacturer that e r an a Eenc�460&10�Ts
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in aacor ect requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402 J.
CODE COMPLIANCE
STD LUCIE COU TY
7/30/2019 12:59 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) ComplNoM Page 1 of 6
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title: WYNNE THE WINDSOR 64 Bedrooms: 3
Address Type:
Street Address
Building Type: User
Conditioned Area: 1753
Lot #
Owner Name:
Total Stories: 1
Block/Subdivision:
# of Units: 1
Worst Case: No
PlatBook:
i Builder Name: WYNNE DEVELOPMENT Rotate Angle: 0
Street:
64 MED EAST
Permit Office: ST. LUCIE COUNTY
Cross Ventilation: No
County:
St. Lucie
Jurisdiction:
Whole House Fan: No
City, State,
Zip:
FT. PIERCE,
Family Type: Single-family
FL,
New/Existing: New (From Plans)
Comment:
CLIMATE
/
Design Temp
Int Design Temp
Heating
Design Daily Temp
V Design Location
TMY Site 97.5 %
2.5 %
Winter
Summer Degree Days Moisture
Range
FL, Fort Pierce FL VERO_BEACH_MUNI 39
90
70
75
299
62
Low
BLOCKS
Number Name
Area Volume
1 Entire House
1753 14024
SPACES
Number Name
Area Volume Kitchen Occupants
Bedrooms
InfilID
Finished Cooled
Heated
1 MASTER BEDROO
224 1792 No
0
1
1
Yes
Yes
Yes
2 WIC
63 504 No
0
1
No
Yes
Yes
3 MASTER BATH
56 448 No
0
1
Yes
Yes
Yes
4 M.BATH
61 488 No
0
1
Yes
Yes
Yes
5 LAUDRY
36 288 No
0
1
No
Yes
Yes
6 BEDROOM 2
180 1440 No
0
1
1
Yes
Yes
Yes
7 DINING/GREAT R
588 4704 No
2
1
Yes
Yes
Yes
8 KITCHEN
209 1672 Yes
0
1
Yes
Yes
Yes
9 BATH
50 400 No
0
1
Yes
Yes
Yes
10 HALL
25 200 No
0
1
No
Yes
Yes
11 FOYER
92 736 No
0
1
Yes
Yes
Yes
12 BEDROOM 3
169 1352 No
0
1
1
Yes
Yes
Yes
FLOORS
# Floor Type
Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood
Carpet
1 Slab -On -Grade Edge Insulatio
MASTER BEDRO 37 ft 0
224 ftz
0 1
0
_ 2 Slab -On -Grade Edge Insulatio
WIC 1 ft 0
63 ftz
__-_
0 1
0
3 Slab -On -Grade Edge Insulatio
MASTER BATH 8 ft 0
56 ftZ
____
0 1
0
1'V
4Slab-On-Grade Edge Insulatio
M. BATH 7 ft 0
61 ftz
---_
0 1
0
5 Slab -On -Grade Edge Insulatio
LAUDRY 1 ft 0
36 ft2
____
0 1
0
7/30/2019 12:59 PM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 6
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
FLOORS
# Floor Type
Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile
Wood Carpet
6 Slab -On -Grade Edge Insulatio
BEDROOM 2 12 ft 0
180 ft2
----
0
1
0
7 Slab -On -Grade Edge Insulatio
DINING/GREAT 50 ft 0
588 ft2
----
0
1
0
8 Slab -On -Grade Edge Insulatio
KITCHEN lift 0
209 ft2
----
0
1
0
9 Slab -On -Grade Edge Insulatio
BATH 5 ft 0
50 ft2
----
0
1
0
10SIab-On-Grade Edge Insulatio
HALL 1 ft 0
25 ft2
----
0
1
0
11Slab-On-Grade Edge Insulatio
FOYER 9 ft 0
92 ft2
----
0
1
0
12SIab-On-Grade Edge Insulatio
BEDROOM 3 14 ft 0
169 ft2
----
0
1
0
ROOF
V
Roof Gable
Roof
Rad
Solar
SA Emitt
Emitt Deck
Pitch
# Type Materials Area Area
Color
Barr
Absor.
Tested
Tested Insul.
(deg)
1 Hip
Metal 1847 ft2 0 ft2
Light
N
0.4
No 0.9
No 0
18.4
ATTIC
V
# Type
Ventilation Vent Ratio (1 in)
Area
RBS
IRCC
1 Full attic
Vented 150
1753 ft2
N
N
CEILING
# Ceiling Type
Space R-Value
Ins Type
Area
Framing Frac
Truss Type
1 Under Attic (Vented)
MASTER BEDRO 30
Blown
224 ft2
0.1
Wood
2 Under Attic (Vented)
WIC 30
Blown
63 ft2
0.1
Wood
3 Under Attic (Vented)
MASTER BATH 30
Blown
56 ft2
0.1
Wood
4 Under Attic (Vented)
M. BATH 30
Blown
61 ft2
0.1
Wood
5 Under Attic (Vented)
LAUDRY 30
Blown
36 ft2
0.1
Wood
6 Under Attic (Vented)
BEDROOM 2 30
Blown
180 ft2
0.1
Wood
7 Under Attic (Vented)
DINING/GREAT 30
Blown
588 ft2
0.1
Wood
8 Under Attic (Vented)
KITCHEN 30
Blown
209 ft2
0.1
Wood
9 Under Attic (Vented)
BATH 30
Blown
50 ft2
0.1
Wood
10 Under Attic (Vented)
HALL 30
Blown
25 ft2
0.1
Wood
11 Under Attic (Vented)
FOYER 30
Blown
92 ft2
0.1
Wood
12 Under Attic (Vented)
BEDROOM 3 30
Blown
169 ft2
0.1
Wood
WALLS
Adjacent
Cavity Width
Height
Sheathing Framing Solar
Below
Space -
-
1
S Exterior Concrete Block - Ext InsMASTER BE 4.1 16
0 8
0
128.0 ft2
0
0
0.3
0
2
N Exterior Concrete Block - Ext InddRSTER BE 4.1 7
0 8
0
56.0 ft2
0
0
0.3
0
3
E Exterior Concrete Block - Ext InsMASTER BE 4.1 14
0 8
0
112.0 ft2
0
0
0.3
0
_ 4
S Exterior Concrete Block - Ext In9MASTER BA 4.1 8
0 8
0
64.0 ft2
0
0
0.3
0
7/30/2019 12:59 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 6
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
WALLS
Adjacent
Cavity Width
Height
Sheathing Framing Solar
Below
Space
5
S
Exterior
Concrete Block - Ext InsuM. BATH
4.1 7
0
8 0
56.0 ft2
0
0
0.3
0
_ 6
S
Exterior
Concrete Block - Ext InfiffDROOM 2
4.1 12
0
8 0
96.0 ft2
0
0
0.3
0
7
N
Exterior
Concrete Block - Ext InQINING/GRE
4.1 30
0
8 0
240.0 ft2
0
0
0.3
0
M
8
E
Exterior
Concrete Block - Ext InQINING/GRE
4.1 20
0
8 0
160.0 ft2
0
0
0.3
0
9
N
Exterior
Concrete Block - Ext InsuKITCHEN
4.1 11
0
8 0
88.0 ft2
0
0
0.3
0
_ 10
S
Exterior
Concrete Block - Ext Insul BATH
4.1 5
0
8 0
40.0 ft2
0
0
0.3
0
11
W
Exterior
Concrete Block - Ext Insul FOYER
4.1 8
0
8 0
64.0 ft2
0
0
0.3
0
12
W
Exterior
Concrete Block - Ext Insul FOYER
4.1 1
0
8 0
8.0 ft2
0
0
0.3
0
13
S
Exterior
Concrete Block - Ext In9IEDROOM 3
4.1 13
0
8 0
104.0 ft2
0
0
0.3
0
14
N
Exterior
Concrete Block - Ext InRffDROOM 3
4.1 1
0
8 0
8.0 ft2
0
0
0.3
0
15
W
Garage
Frame - Wood BEDROOM 3
11 26
8
208.0 ft2
0.23
0.3
0
DOORS
#
Ornt
Door Type Space
Storms
U-Value
Width
Height
Area
Ft In
Ft In
1
SE
Insulated FOYER
None
.32
3
3
6 8
21.7 ft2
WINDOWS
Orientation shown is the entered, Proposed orientation.
/
Wall
Overhang
#
Ornt ID
Frame Panes NFRC U-Factor SHGC
Imp
Area
Depth
Separation
Int Shade
Screening
1
E 3
Metal Low-E Single Yes
1.04 0.29
N
32.4 ft2
1 ft 0 in
1 ft 4 in
Drapes/blinds
Exterior 5
2
S 5
Metal Low-E Single Yes
1.04 0.29
N
6.9 ft2
1 ft 0 in
1 ft 4 in
None
None
3
S 6
Metal Low-E Single Yes
1.04 0.29
N
16.2 ft2
1 ft 0 in
1 ft 4 in
None
None
4
N 7
Metal Low-E Single Yes
1.04 0.29
N
39.8 ft2
1 ft 0 in
1 ft 4 in
None
None
5
E 8
Metal Low-E Single Yes
1.11 0.27
N
40.0 ft2
8 ft 0 in
1 ft 4 in
None
None
6
S 13
Metal Low-E Single Yes
1.04 0.29
N
16.2 ft2
1 ft 0 in
1 ft 4 in
Drapes/blinds
Exterior 5
GARAGE
#
Floor Area Ceiling Area Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1
806 ft2 806 ft2
26 ft
8 ft
11
INFILTRATION
# Scope
Method SLA CFM 50 ELA
EgLA
ACH
ACH 50
1 Wholehouse Proposed ACH(50) .000356 1636.1 89.82
168.92
.1233
7
7/30/2019 12:59 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 6
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
HEATING SYSTEM
#
System Type
Subtype
Efficiency
Capacity
Block
Ducts
1
Electric Heat Pump/
Split
HSPF:8.5
34.8 kBtu/hr
1
sys#1
COOLING SYSTEM
#
System Type
Subtype
Efficiency
Capacity
Air Flow
SHR
Block
Ducts
1
Central Unit/
Split
SEER: 15 34.8 kBtu/hr cfm
0.85
1
sys#1
HOT WATER SYSTEM
#
System Type
SubType
Location
EF Cap Use
SetPnt
Conservation
1
Electric
None
Garage
0.97 40 gal 60.9 gal
120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Collector
Storage
Cert
# Company Name
System Model # Collector Model
# Area
Volume
FEF
None None
ftZ
DUCTS
/
— Supply ---
-- Return —
Air
CFM 25
CFM25
HVAC #
v #
Location R-Value Area
Location
Area Leakage Type
Handler
TOT
OUT
QN
RLF
Heat Cool
1
Attic
6 245 ftz
Attic
55 ft2 Default Leakage
Attic
(Default)
(Default)
1 1
TEMPERATURES
Programable Thermostat: Y
Ceiling Fans:
Coolln
Venting
Jan Feb
Jan Feb
Mar
HX Mar
Apr
Apr
Ma y
i May rl Jun ri Jul
ri Aug
Sep
rl
Oct
Oct
Nov
ki Nov
Dec
H Dec
Jun [ Jul
[ Aug
Sep
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2 3
4 5 6
7
8
9
10
11
12
Cooling (WD)
AM
78
78 78
78 78 78
78
78
80
80
80
80
PM
80
80 78
78 78 78
78
78
78
78
78
78
Cooling (WEH)
AM
78
78 78
78 78 78
78
78
78
78
78
78
PM
78
78 78
78 78 78
78
78
78
78
78
78
Heating (WD)
AM
66
66 66
66 66 68
68
68
68
68
68
68
PM
68
68 68
68 68 68
68
68
68
68
66
66
Heating (WEH)
AM
66
66 66
66 66 68
68
68
68
68
68
68
PM
68
68 68
68 68 68
68
68
68
68
66
66
7/30/2019 12:59 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 6
FORM R405-2017
INPUT SUMMARY CHECKLIST REPORT
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default(8 Ibs/sq.ft.
0 ftZ
0 ft
0.3
BEDROOM
Default(8 Ibs/sq.ft.
ftZ
ft
0.3
WIC
} Default(8 Ibs/sq.ft.
ftz
ft
0.3
M. BATH
Default(8 lbs/sq.ft.
ftZ
ft
0.3
KITCHEN
Default(8 Ibs/sq.ft.
ftz
ft
0.3
BATH
Default(8 Ibs/sq.ft.
ftz
ft
0.3
BEDROOM 2
Default(8 lbs/sq.ft.
ft2
ft
0.3
ENTRY
Default(8 Ibs/sq.ft.
ftZ
ft
0.3
LAUNDRY
Default(8 Ibs/s .ft.
ftZ
ft
0.3
GREAT/DINING
V
7/30/2019 12:59 PM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 6 of 6
2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: WYNNE THE WINDSOR 64 Builder Name: WYNNE DEVELOPMENT
Street: 64 MED EAST Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE, FL, Permit Number:1906-0175
Y
U
Owner: Jurisdiction:
w
Design Location: FL, Fort Pierce
U
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General
A continuous air barrier shall be installed in the building envelope.
Air -permeable insulation shall
requirements
The exterior thermal envelope contains a continuous air barrier.
not be used as a sealing material.
Breaks or joints in the air barrier shall be sealed.
Ceiling/attic
The air barrier in any dropped ceiling/soffit shall be aligned with
The insulation in any dropped ceiling/soffit
the insulation and any gaps in the air barrier shall be sealed.
shall be aligned with the air barrier.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls
The junction of the foundation and sill plate shall be sealed.
Cavities within corners and headers of frame walls
The junction of the top plate and the top of exterior walls shall be
shall be insulated by completely filling the cavity
sealed.
with a material having a thermal resistance of R-3
Knee walls shall be sealed.
per inch minimum.
Exterior thermal envelope insulation for framed
walls shall be installed in substantial contact and
continuous alignment with the air barrier.
Windows, skylights
The space between window/doorjambs and framing, and
and doors
skylights and framing shall be sealed.
Rim joists
Rim joists shall include the air barrier.
Rim joists shall be insulated.
Floors
The air barrier shall be installed at any exposed edge of
Floor framing cavity insulation shall be installed to
(including
insulation.
maintain permanent contact with the underside of
above -garage
subfloor decking, or floor framing cavity insulation
and cantilevered
shall be permitted to be in contact with the top side
floors)
of sheathing, or continuous insulation installed on
the underside of floor framing and extends from the
bottom to the top of all perimeter floor framing
members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered with
Where provided instead of floor insulation, insulation
a Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawlspace
Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to
exterior or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
Narrow cavities
cavities shall be filled by insulation that on
installation readily conforms to the available cavity
spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spac
3s.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope
Recessed light fixtures installed in the building
shall be sealed to the drywall.
thermal envelope shall be air tight and IC rated.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring
and plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
extend behind p*pmng and waring.
Shower/tub
The air barrier installed at exterior walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall
on exterior wall
tubs shall separate them from the showers and tubs.
be insulated.
Electrical/phone box or
The air barrier shall be installed behind electrical or communication
exterior walls
boxes or air -sealed boxes shall be installed.
HVAC register boots
HVAC register boots that penetrate building thermal envelope shall
be sealed to the sub -floor or drywall.
Concealed
When required to be sealed, concealed fire sprinklers shall only be
sprinklers
sealed in a manner that is recommended by the manufacturer.
Caulking or other adhesive sealants shall not be used to fill voids
between fire snrinkler cover plates and walls or ceffilmnas-
a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400.
7/30/2019 12:59 PM EnergyGauge@ USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
2017 EPL DISPLAY CARD
1
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 97
The lower the Energy Performance Index, the more efficient the home.
1. New home or, addition
1. New (From Plans)
12. Ducts, location & insulation level
a) Supply ducts R
6.0
2. Single-family or multiple -family
2. Single-family
b) Return ducts R
6.0
c) AHU location
Attic
3. No. of units (if multiple -family)
3.
1
4. Number of bedrooms
4.
3
13. Cooling system: Capacity
34.8
a) Split system SEER
15.0
5. Is this a worst case? (yes/no)
5.
No
b) Single package SEER
c) Ground/water source SEER/COP
6. Conditioned floor area (sq. ft.)
6.
1753
d) Room unit/PTAC EER
e) Other
7. Windows, type and area
a) U-factor:(weighted average)
7a.
1.058
b) Solar Heat Gain Coefficient (SHGC)
7b.
0.285
14. Heating system: Capacity
34.8
c) Area
7c.
151.4
a) Split system heat pump HSPF
8.5
b) Single package heat pump HSPF
8. Skylights
c) Electric resistance COP
a) U-factor:(weighted average)
8a.
NA
d) Gas furnace, natural gas AFUE
b) Solar Heat Gain Coefficient (SHGC)
8b.
NA
e) Gas furnace, LPG AFUE
f) Other
9. Floor type, insulation level:
a) Slab -on -grade (R-value)
9a.
0.0
b) Wood, raised (R-value)
9b.
15. Water heating system
c) Concrete, raised (R-value)
9c.
a) Electric resistance EF
0.97
b) Gas fired, natural gas EF
10. Wall type and insulation:
c) Gas fired, LPG EF
A. Exterior:
d) Solar system with tank EF
1. Wood frame (Insulation R-value)
10A1.
e) Dedicated heat pump with tank EF
2. Masonry (Insulation R-value)
10A2.
4.1
f) Heat recovery unit HeatRec%
B. Adjacent:
g) Other
1. Wood frame (Insulation R-value)
10131.
11.0
2. Masonry (Insulation R-value)
10132.
16. HVAC credits claimed (Performance Method)
11. Ceiling type and insulation level
a) Ceiling fans
a) Under attic
11a.
30.0
b) Cross ventilation
No
b) Single assembly
11 b.
c) Whole house fan
No
c) Knee walls/skylight walls
11c.
d) Multizone cooling credit
d) Radiant barrier installed
11 d.
No
e) Multizone heating credit
0 Programmable thermostat
Yes
*Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT
I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy
saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL
display card will be completed based on installed code compliant features.
Builder Signature: Date:
Address of New Home: 64 MED EAST City/FL Zip: FT. PIERCE, FL
7/30/2019 12:59:34 PM EnergyGauge@ USA 6.0.03 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1