HomeMy WebLinkAboutNOA; Profile Vent for Metal RoofsHIAMP
in MIAMI-DADE COUNTY
PRODUCT CONTROL SECTION
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Street, Room 208
BOARD AND CODE ADMINISTRATION DIVISION Miami, Florida 33175-2474
T (786) 315-2590 F (786) 315-2599
NOTICE OF ACCEPTANCE (NOA) www.miamidade.gov/ecoiiomy
Ventco Inc.
115 Lismore Avenue
Glenside, PA. 19038
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section
(In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this
product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted
manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or
suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance,
if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the
requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: ProfileVent for Metal Roofs
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product,
for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section
of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This renews NOA# 07-0626.08 and consists of pages 1 through 4.
The submitted documentation was reviewed by Alex Tigera.
NOA No.: 12-0724.03
Expiration Date: 11/29/17
Approval Date: 12/27/12
age 1 of 4
r
ROOFING COMPONENT APPROVAL
Category: Roofing
Sub -Category: Ventilation
Material: Plastic
Minimum Slope: 3:12
TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT
Product Dimensions Test Product
Specification Description
ProfileVent Ht. = 1" TAS 100(A) Plastic low profile attic ridge vent consisting of a
Width = 3" two layer composite consisting of a nylon -
Lengths = 20' roll polyester, for installation in shingle roof systems.
50' roll
100' roll
500' roll
TRADE NAMES OF PRODUCTS MANUFACTURED BY OTHERS:
Test IProduct
Product Dimensions Specification Description Manufacturer
Hex Head Screw with Min #14 x 2" TAS114 Corrosion resistant, hex head Generic
Weather Seal Washer screw with weather seal washer.
MANUFACTURING LOCATION
1. Wrens, GA.
EVIDENCE SUBMITTED
Test Agency/Identifier Name
Architectural Testing 71302.02-109-18
Architectural Testing 56017.09-122-18
Re ort
Date
TAS-100(A)
09/25/07
ASTM D 1929
09/25/07
ASTM D635
06/13/07
ASTM D 2843
NOA No.: 12-0724.03
Expiration Date: 11/29/17
Approval Date: 12/27/12
Page 2 of 4
APPROVED APPLICATIONS:
Trade Name: ProfileVent
System Type A: Mechanical attachment of static ridge vent over metal roof panels and under Metal roof
ridge cap.
Installation: 1. Allow a 3" opening centered in the deck at the ridge for ventilation. The slot shall
terminate approximately 12" from the rake edges.
2. Rollout ProfileVent along ridge about''/z" to 1" up -slope from edge of metal roof ridge
cap from gable to gable.
3. ProfileVent can be cut with scissors or utility knife.
4. When splicing ProfileVent make the splice at the center top of the high rib acid use
caulk or sealant along the splice
5. Fasten the metal roof ridge cap according to the metal roof manufacturer's instructions;
but in no case shall it be less than a #14 x 2" corrosion resistant hex head screw with a
weather seal washer fastened at a maximum spacing of 9" o.c. along both sides of metal
roof ridge cap and through each rib of the metal roof panel.
Net Free Area: Refer to Manufacturer's Published Literature
Minimum Slope: 3:12
LIMITATIONS:
1. Refer to applicable Building Code required ventilation.
2. Ridge Vent shall comply with applicable Building Code.
3. Ridge Vent shall not be installed on roof mean heights greater than 33 feet.
4. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and
Rule 9N-3 of the Florida Administrative Code.
MIAMt•DADE COUNTY
NOA No.: 12-0724.03
Expiration Date: 11/29/17
Approval Date: 12/27/12
Page 3 of 4
DETAIL A
Various lengths
I+ - 9.00 TYP - .75 .094
--� 3.13 NP
2.75 NP -
DETAIL "A'
+- 1.625
Detail A Detail B
INSTALLATION DETAILS
/ ----Metal Ridge Cap l—
Metal Roof
I— Polymer Ventilation
Plywood Deck Material
End View
Per Metal Roof
Manufacturers Instructions
but no more than 9" o.c. maximum
Isometric View
END OF THIS ACCEPTANCE
--4.937I -
DETAIL 'B'
Metal Roof Fasteners
#14 x 2" Minimum Hex Head
screw wA%W
Material
NOA No.: 12-0724.03
Expiration Date: 11/29/17
Approval Date: 12/27/12