HomeMy WebLinkAboutRevision; No Profile Vent Installed11/08/2016 99:17 7722877763
CODE RED ROOFERS PAGE 01/0'.
OMCE USE ONLY;
DATRFILED:
)REVISION PEE:
1.
2.
ADDRESS:
PERMIT ,#
RECEIPT #
PLANNING & DRVELOPMENT SERVICES
I;UII.TDING & CODE REGULATION DIVISION
2300 VIRGMA AVENUE
,FORT PiERCF, FL 34982-5692
(772) 462.1553 FAX (M) 4624S78
APPLICATION FOR BLUDING PERMIT REVXSIONS
PROJECT INFORMATION
DETAILED DESCRIPTION OI; PROJECT
REVISIONS:
o Le caw r 15kLc(tj
3. CONTRACTOR INFORMATION.
STATE of YL REGJCERT. #: I vJ�" !7 S X,U COUNTX' CERT. :
BUSINESS NAME: .
QUALIFIERS NAME:
ADDRESS: E rr
CITY: STATE:
PHONE (DAYTIME): T FAX:
4. OWNER/DUILDER INFORMATION:
NAME:
ADDRESS;
CITY: STATE:
PHONE: FAX:
5. ARCHITECT/ENGINEER WORMATION:
NAME:
ADDRESS:
CITY:. .
EIEYdNE (DAXTI1VVlE): `r� ®' FAX; _
Revised 07i12/2014 1�
,ZIP:
ZIP:
ZIP:
FILE COPY
a Certificate of Authorization No. 29824
RE
17520 Edinburgh Dr
Tampa, FL 33647
TECHNICAL SERVICES, LLC (813)480-3421
EVALUATION REPORT FLORIDA BUILDING CODE, 6" EDITION (2017)
Manufacturer: L.V. Thompson, Inc. issued October9, 2017
dba Thompson Architectural Metals Company (TAMCO)
5015 E. Hillsborough Ave
Tampa, FL 33610
(813) 248-3456
http://www.tamcometaIroof.com
Manufacturing Plant: Tampa, FL
Quality Assurance: Keystone Certifications (QUA1824)
SCOPE
Category:
Roofing
Subcategory:
Roofing Accessories that are an Integral Part of the Roofing System.
Code Sections:
1503.5, 1709.2
Properties:
Roof Ventilation
REFERENCES
Entity Report No. Standard Year
PRI Construction Materials Technologies (TST5878) LVTI-013=02-01 ASTM E 330 2002
PRODUCT DESCRIPTION
TAMCO Gooseneck Vent: Minimum 26 ga. ASTM A792 or ASTM A653 galvanized steel; Fy = min. 50 ksi;
maximum dimensions of the vent duct are 10" wide x 10" long x 8-3/4". Vent
contains a 3" wide mounting flange on all four sides with pre -punched holes located
in each of the four corners. Material shall conform with FBC Section 1507.4,3.
RE -VISION
LVT14001,2d FL 16918-112 FILE Copoy
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid'
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
1
E � ; K L.V. Thompson, Inc.(TAMCO)
u `�' TAMCO Gooseneck Vent
TECHNICAL SERVICES, LLC
APPLICATION
Deck Type: Minimum 1.5/32-inch APA span rated plywood sheathing or minimum 7/16-inch OSB
for new and existing roof deck; (Deck shall be designed by others in accordance
with FBC requirements)
Roof slope: Minimum 4:12
Installation Height: Maximum 33-ft
Attachment Method: Cut out the Gooseneck Vent opening in the roof sheathing according within
maximum dimensions. Do not cut into trusses or rafters when cutting opening in the
roof.
Remove interfering shingle nails around the perimeter of the opening and any debris
so that the nailing flange of the vent lays flat,to the roof sheathing. Slide the top and
side flanges of the vent underneath the shingles and allow the bottom flange to lie
on the top of the shingles. Care should be taken in keeping the vent properly
aligned. Vent.pipe is sealed if utilized. Nail in place,using four (4) minimum 12 ga.
x 1-1/2" smooth shank located at each corner (fasteners shall conform with FBC
Section 1506.5). Roofing cement should be applied to all shingle edges near the,
outer edge and around the entire perimeter.
Allowable Roof Coverings: Asphalt shingles
Maximum Design Pressure -52.5 psf for installations over plywood deck
-22.5 psf for installation over OSB deck
Pressures calculated using 2:1 margin of safety per 1504.9.
LVT14001.2d FL 16918-R2 Page 2 of 3
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this reportis valid..
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
tipEEK L.V. Thompson, Inc. (TAMCO)
j(`� TAMCO Gooseneck Vent
TECHNICAL SERVICES, LLC
LIMITATIONS
1) Fire Classification is outside the scope of this evaluation.
2) This report is not for use in the HVHZ. '
3) The roof deck and deck attachment shall be designed by others in accordance: with the. FBC.
4) All products listed in this report shall be manufactured under a quality assurance program in compliance with
Rule 61 G20-3.
5) TAMCO vents shall be installed in strict compliance with this evaluation report and the manufacturers
published installation instructions. In the event of conflict, the more restrictive installation shall be enforced:
6) Deck substrates shall be clean, dry, and free from any irregularities and debris. All fasteners in the deck
shall be checked -for protrusion prior to installation.
7) Installation of the roof assembly is outside the scope of this evaluation.
8) TAMCO vents are intended to provide passive ventilation for an enclosed attic in residential construction
applications.
COMPLIANCE STATEMENT
The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building
Code, 61h Edition (2017) as evidenced in the referenced documents submitted by the named manufacturer.
R. p
SPRY .
G G•E N' .
2017.10.09
• • �'
No 74021/A/Z�5-
1 :27:n 6
`
-A 1 001
� '.• STATE OF
OR 10
N AI-
�,O S
rr1110
Florida Registration No. 74021
Organization No, ANES641
CERTIFICATION OF INDEPENDENCE
CREEK Technical Services, LLC does not have, nor will it acquire, a financial interest in any company manufacturing or distributing
products under this evaluation.
CREEK Technical Services, LLC is not owned, operated; or controlled by any company manufacturing or distributing products under
this. evaluation.
Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any company manufacturing or distributing products
under this evaluation.
Zachary, R. Priest, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
END OF REPORT
LVT14001.2d FL 16918-R2 Page 3 of 3
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify. CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report Is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.