HomeMy WebLinkAboutRevision; No Profile Vent Installed11/08/2016 99:17 7722877763 CODE RED ROOFERS PAGE 01/0'. OMCE USE ONLY; DATRFILED: )REVISION PEE: 1. 2. ADDRESS: PERMIT ,# RECEIPT # PLANNING & DRVELOPMENT SERVICES I;UII.TDING & CODE REGULATION DIVISION 2300 VIRGMA AVENUE ,FORT PiERCF, FL 34982-5692 (772) 462.1553 FAX (M) 4624S78 APPLICATION FOR BLUDING PERMIT REVXSIONS PROJECT INFORMATION DETAILED DESCRIPTION OI; PROJECT REVISIONS: o Le caw r 15kLc(tj 3. CONTRACTOR INFORMATION. STATE of YL REGJCERT. #: I vJ�" !7 S X,U COUNTX' CERT. : BUSINESS NAME: . QUALIFIERS NAME: ADDRESS: E rr CITY: STATE: PHONE (DAYTIME): T FAX: 4. OWNER/DUILDER INFORMATION: NAME: ADDRESS; CITY: STATE: PHONE: FAX: 5. ARCHITECT/ENGINEER WORMATION: NAME: ADDRESS: CITY:. . EIEYdNE (DAXTI1VVlE): `r� ®' FAX; _ Revised 07i12/2014 1� ,ZIP: ZIP: ZIP: FILE COPY a Certificate of Authorization No. 29824 RE 17520 Edinburgh Dr Tampa, FL 33647 TECHNICAL SERVICES, LLC (813)480-3421 EVALUATION REPORT FLORIDA BUILDING CODE, 6" EDITION (2017) Manufacturer: L.V. Thompson, Inc. issued October9, 2017 dba Thompson Architectural Metals Company (TAMCO) 5015 E. Hillsborough Ave Tampa, FL 33610 (813) 248-3456 http://www.tamcometaIroof.com Manufacturing Plant: Tampa, FL Quality Assurance: Keystone Certifications (QUA1824) SCOPE Category: Roofing Subcategory: Roofing Accessories that are an Integral Part of the Roofing System. Code Sections: 1503.5, 1709.2 Properties: Roof Ventilation REFERENCES Entity Report No. Standard Year PRI Construction Materials Technologies (TST5878) LVTI-013=02-01 ASTM E 330 2002 PRODUCT DESCRIPTION TAMCO Gooseneck Vent: Minimum 26 ga. ASTM A792 or ASTM A653 galvanized steel; Fy = min. 50 ksi; maximum dimensions of the vent duct are 10" wide x 10" long x 8-3/4". Vent contains a 3" wide mounting flange on all four sides with pre -punched holes located in each of the four corners. Material shall conform with FBC Section 1507.4,3. RE -VISION LVT14001,2d FL 16918-112 FILE Copoy This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid' This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. 1 E � ; K L.V. Thompson, Inc.(TAMCO) u `�' TAMCO Gooseneck Vent TECHNICAL SERVICES, LLC APPLICATION Deck Type: Minimum 1.5/32-inch APA span rated plywood sheathing or minimum 7/16-inch OSB for new and existing roof deck; (Deck shall be designed by others in accordance with FBC requirements) Roof slope: Minimum 4:12 Installation Height: Maximum 33-ft Attachment Method: Cut out the Gooseneck Vent opening in the roof sheathing according within maximum dimensions. Do not cut into trusses or rafters when cutting opening in the roof. Remove interfering shingle nails around the perimeter of the opening and any debris so that the nailing flange of the vent lays flat,to the roof sheathing. Slide the top and side flanges of the vent underneath the shingles and allow the bottom flange to lie on the top of the shingles. Care should be taken in keeping the vent properly aligned. Vent.pipe is sealed if utilized. Nail in place,using four (4) minimum 12 ga. x 1-1/2" smooth shank located at each corner (fasteners shall conform with FBC Section 1506.5). Roofing cement should be applied to all shingle edges near the, outer edge and around the entire perimeter. Allowable Roof Coverings: Asphalt shingles Maximum Design Pressure -52.5 psf for installations over plywood deck -22.5 psf for installation over OSB deck Pressures calculated using 2:1 margin of safety per 1504.9. LVT14001.2d FL 16918-R2 Page 2 of 3 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this reportis valid.. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. tipEEK L.V. Thompson, Inc. (TAMCO) j(`� TAMCO Gooseneck Vent TECHNICAL SERVICES, LLC LIMITATIONS 1) Fire Classification is outside the scope of this evaluation. 2) This report is not for use in the HVHZ. ' 3) The roof deck and deck attachment shall be designed by others in accordance: with the. FBC. 4) All products listed in this report shall be manufactured under a quality assurance program in compliance with Rule 61 G20-3. 5) TAMCO vents shall be installed in strict compliance with this evaluation report and the manufacturers published installation instructions. In the event of conflict, the more restrictive installation shall be enforced: 6) Deck substrates shall be clean, dry, and free from any irregularities and debris. All fasteners in the deck shall be checked -for protrusion prior to installation. 7) Installation of the roof assembly is outside the scope of this evaluation. 8) TAMCO vents are intended to provide passive ventilation for an enclosed attic in residential construction applications. COMPLIANCE STATEMENT The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building Code, 61h Edition (2017) as evidenced in the referenced documents submitted by the named manufacturer. R. p SPRY . G G•E N' . 2017.10.09 • • �' No 74021/A/Z�5- 1 :27:n 6 ` -A 1 001 � '.• STATE OF OR 10 N AI- �,O S rr1110 Florida Registration No. 74021 Organization No, ANES641 CERTIFICATION OF INDEPENDENCE CREEK Technical Services, LLC does not have, nor will it acquire, a financial interest in any company manufacturing or distributing products under this evaluation. CREEK Technical Services, LLC is not owned, operated; or controlled by any company manufacturing or distributing products under this. evaluation. Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any company manufacturing or distributing products under this evaluation. Zachary, R. Priest, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. END OF REPORT LVT14001.2d FL 16918-R2 Page 3 of 3 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify. CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report Is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein.