Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Design Pressures
Property Information Owner:Jhoana Daza Address:322 SE Tranquilla Avenue Port Saint Lucie, FL 34983 Building Information Wind Zone:160 MPH. Exposure Category:C Minimum Building Dimension:30 ft. Mean Roof Height:12 ft. Risk Category:II Design Pressure Calculations Opening Number Location Zone Device Width (in) Device Height (in) Device Elevation (ft) Max Positive Pressure (psf) Max Negative Pressure (psf) 1 End 37 38 7 33.5 -44.8 2 End 37 38 7 33.5 -44.8 3 End 74 50 7 31.4 -40.7 4 End 106 50 7 30.6 -39.2 5 End 53 38 7 32.7 -43.4 6 End 37 26 7 33.5 -44.8 7 End 106 26 7 31.4 -40.7 8 End 53 50 7 32.2 -42.2 9 End 53 50 7 32.2 -42.2 10 End 37 26 7 33.5 -44.8 Prepared in accordance with: ASCE 7-10, Chapter 30. Wind Loads - Components and Cladding. 6th Edition (2017) Florida Building Code. Page 1 of 1