HomeMy WebLinkAboutTROP FMW1 MANF SPECPAC -CLQ O
102 Northpoint Parkway
Building 106
Acworth, GA 30102
(800) 272-4482
Compliant with Florida Building Code 2017 (6u' ed.)
Compliant with Florida Product Approval Rule # 61G20-3
Compliant Quality Assurance Program: UL LLC
Snap-On standing seam panels with concealed clips @ 12" o.c. with snap -on batten caps over clips and i" high legs fastened to
19/32" plywood deck w/ corrosion resistant (2) #10-12 fasteners per clip. Clips are concealed between the adjacent vertical legs
of the panels & a batten cap is installed over the outside of the vertical legs to retainer lugs on the clips. Panel Width: 12"
**Design Pressure: Material: Support Spacing:
41.6 PSF 24 GA 1'-0" o.c.
I 41.3 PSF .032" Alum. 1'-0" o.c. I
16oz Copper Snap -Clad panel with clips thru fastened to 19/32" thick APA plywood, grade B -C fastened with corrosion resistant
(2) #10-16 x 1" long, SS, pancake head fasteners; two per clip. Manufacturer requires stainless steel fasteners. Panel Clip: one
piece 3-%" wide x 1-7/8" high with a 1-3/8" wide, horizontal leg fabricated from No. 18 MSG stainless steel. Panel width: 16" wide
by 1-3/4" high rib at the female panel, sealant allowed at panel side joints. An underlayment of 60 MIL "high temperature"
membrane is required by manufacturer. Fasteners thru clips to substrate are concealed behind the adjacent nesting/lapping
vertical ribs of the panels.
The panels were attached to the perimeter of the wood deck at 6" o.c. Panel Clip: Tite-Loc 2 -Piece clips w/ #10-12 x 1" fasteners.
0.040" Alum. X 12"
0.040" Alum. X 16"
**Design Pressure:
Clip Spacing:
**Design Pressure:
Clip Spacing:
107.9 PSF
24" o.c.
76.7 PSF
24" o.c.
146.9 PSF
12" o.c.
87.15 PSF
12" o.c.
152.1 PSF
6" o.c.
105.3 PSF
6" o.c.
M-36 Panel installed over 16GA Steel purlins @ 12" o.c. w/ the shorter side of the system fastened using corrosion resistant (1)
#12 x 1-1/4" HWH SDS w/ neoprene washer (per manufacturer) @ ea. valley located 6" o.c. The first panel & ea. panel joint was
fastened at the longer side of the system using a single row of #12 x 1-1/4" HWH SDS w/ neoprene washer (per manufacturer) @
12" o.c.
24GA Steel 0.032" Aluminum
**Design Pressure: Spacing: **Design Pressure: Spacing:
-80 PSF @ S' O.C. -70 PSF @ 5' O.C.
-120 PSF @ 1' O.C. -107 PSF ' o.c.
SEF LOAD TABLES FOR MORE AVAILABLEfry
**DESIGN PRS1&YhyaLly®f:S;/i�i7jY MARGIN Of Z:1
STATE OF ' �✓
FS 0 0. 6114�43/ONA%_ ON
• t�C� �.•
The panels were installed over 166A supports fastened w/ corrosion resistant #12-14 x-1" self -drill fasteners w/ 0.»" diza. seal
washer head spaced as shown on the install detail. Panel side joints were overlapping using corrosion resistant #12-14 x;/." self -
drill lap fasteners w/ 0.55" dia. seal washer head located at 12" o.c.
22GA 24GA
**Design Pressure: Spacing **Design Pressure. Spacing:
-52.8 PSF @ S' O.C. -49.5 PSF @ 5' O.C.
-154.1 PSF I @ 2' o.c.
-159.1 PSF I @ 2' o.c.
0.032" Aluminum
0.040" Aluminum
?sign Pressure:
Spacing
**Design Pressure:
Spacing:
-28.0 PSF
@ 5' O.C.
-49.7 PSF
@ 5' O.C.
-143.2 PSF
9D Z' o.c.
-443.2 PSF
0 2' e_r_
1 ne panels were installed over 16GA supports fastened w/ corrosion resistant 1/4" —14 x 1-1/4" long hex head self -drill fastener
with 5/8" seal washer located at every low cell of the panel. The panel side joints were overlapping cor rosic:, r G;istant n12-14
1" long hex head self -drill fasteners w/ 5/8" seal washer @ 18" o.c.
24GA Steel 0.032" Alum.
Gauge **Design Pressure: Spacing: **design Pressure: Spacing:
-78.8 PSF I @ 5' O.C. -61.1 PSF @ 5' O.C.
The 24GA Steel panels were fastened over 16GA supports using corrosion resistant Y4"-14 x 1-1/4" long hex head self-driii
fasteners w/ 5/8" seal washer located at every other low cell of the panel as shown on install details. The fixed end :vas fast-md
at every low cell of the panel. The panel side -joints were single overlapping fastened w/ corrosion resistant #12-14 x 1" Ione hex
head self -drill fasteners w/ 5/8" seal washer @ 12" o.c.
24GA Steel
esign Pressure: Spacing:
-78.6 PSF @ S' O.C.
-159.8 PSF @ 2' o.c.
The 0.03Z" Aluminum panels were fastened over 16GA supports using corrosion resistant YO -14 x 1-1/4" lona hex head self -drill
fasteners w/ 5/8" seal washer located at every other low cell of the panel as shown on install details. The faxed end was f�3tC%ICd
at every low cell of the panel. The panel side -joints were overlapping fastened w/ corrosion resistant #12-14 x 1" lone hex head
self -drill fasteners w/ 5/8" seal washer @ 12" o.c.
0.032" Aluminum
**Design Pressure: Spacing:
-47.1 PSF @ 5' O.C.
-156.4 PSF @ 2' o.c.
Standing seam panel was fastened over min. 22GA, Grade 33 B -deck @ max. 5' o.c. with clip using corrosion resistarit If'-) #14-10
Dekfast screws per clip'through 4" x 5" x 16GA bearing plate and rigid insulation into deck; fastener should be of sfiffiriant 1pneth
to penetrate min. %" through the deck. Tite-Loc Plus AR sliding clip: 2 fasteners per clip, Clip Tab: 4.313" wide, Suksi, 22GA 690
Coated Steel; Clip Base: 2.5" wide, 50ksi,18GA G90 coated steel. MSA "Quick Stick HT" 40 mil peel & stick or approved equal.
Installed over insulation board as per manufacturer's install guidelines. insulation board: 2" min. - 4" max. thickness to coma_ Iv w/
FBC 2017. Slope Y4:12 or greater in accordance w/ FBC 2017. Rib Height: 2"
**Design Pressure:
Clip Spacing:
-S2.S PSF
@ 48" o.c.
_
-160.95 PSF
@ 12" o.c.
**DESiGR8fNM� C ES A .SAFETY MARGIN OF 2:1
Certificate of independence: ;$,� • • • • * •v•
Locke Bowden, P.E. does not have, not will acquire a financial interestw171�r.cbRitt�rfantlfis>ig or distributing produrts
under this evaluation. . •
�a
NQ, 49704 ,*Mi�
Locke Bowden, P.E. is not owned, operated, or controlled by any conspppV, manufcturer, or diStrib4jing products :.....,..r o this
report. ' •