HomeMy WebLinkAboutTROP FMW1 PROD APP6/28/2018
Florida Building Code Online
SCIS Home Log In User Registration Hot Topics Submit Surcharge Stats & Facts
db6 r
Product Approval
USER: Public User
Product Approval Menu > Product or Application Search > Application List > Application Detail
FL # FL23953
Application Type New
Code Version 2017
Application Status Approved
Comments
Archived
�s.
I
Publications Contact Us BCIS Site Map Links Search
Product Manufacturer Petersen Aluminum Corporation
Address/Phone/Email 102 Northpoint Parkway
Building 106
Acworth, GA 30102
(800)272-4482
dlandis@petersenmail.com
Authorized Signature Sal Delfino
sdeifino@petersenmaii.com
Technical Representative Sal Delfino
Address/Phone/Email 102 Northpoint Parkway
Building 106
Acworth, GA 30102
(954)931-1392
sdelfino@petersenmail.com
Quality Assurance Representative Tom Creigh, VP
Address/Phone/Email Petersen Aluminum, Inc.
1005 Tonne Road
Elk Grove, IL 60007
(800) 722-7150
tcreigh@petersenmaii.com
Category Roofing
Subcategory Metal Roofing
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed the Locke Bowden
Evaluation Report
ASTM E 1592
Florida License
PE -49704
Quality Assurance Entity
UL LLC
Quality Assurance Contract Expiration Date
06/30/2019
Validated By
Zachary R. Priest, P.E.
Validation Checklist - Hardcopy Received
Certificate of Independence
FL23953 RO COI FL 23953 PETERSEN ALUM REPORT om lee- .pdf
Referenced Standard and Year (of Standard) Standard
Year
ASTM E 1592
2005
TAS 125
2003
UL 1897
2012
UL 580
2006
https://floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQmdDquSl Bu8CAEmBKm5WPFwLdekOBUlbh8uCEfxrZfkBEgzow%3d%3d 115
6/28/2018
Florida Building Code Online
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted
10/16/2017
Date Validated
10/29/2017
Date Pending FBC Approval
10/30/2017
Date Approved
12/12/2017
iummary of Products
FL # Model, Dumber or Name
23953.1 2.67" x 7/8" Corrugated Panels
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: No
Design Pressure: N/A
Other: ASTM 1592-01 Tested Loads open framing with 2.0
Safety Factors: 24 Gage Steel: 5'0"= -78.6 PSF 2'0"= -159.8
PSF .032" Aluminum: 5'0"=-47.1 PSF 2.0"= -156.4 PSF
23953.2 7.2' Rib Panel
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: N/A
Other: ASTM 1592 Tested Loads open framing: 24 Gage Steel
5'0"=-78.8 PSF, 2'0"= -159.7 PSF .032" Aluminum: 5'0"=
-61.1 PSF 2'0"= -104.0 PSF
23953.3 Edge -Loc 1.0 (.032" min.)
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/ -52.5
Other: The use of a Class "A" fire barrier is not required
outside the HVHZ unless otherwise specified in the building
code. Design pressure includes a safety factor=2:0. Fasteners
to be corrosion resistant. All materials and installation to be in
compliance with FBC (2014) 5th Edition.
23953.4 Large Precision Tile Panel: Aluminum
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/ -202
Other:
23953.5 Large Precision Tile Panel: Steel
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/ -248
Other:
Gage Steel and .032" Aluminum
Installation Instructions
FL23953 RO II FL 23953 Petersen Aluminum Detail Binder
SS.p_df
Verified By: Locke Bowden, P.E. 49704
Created by Independent Third Party: Yes
Evaluation Reports
FL23953 RO AE FL 23953 PETERSEN ALUM REPORT
complete-SS.pdf
Created by Independent Third Party: Yes
24 Gage Steel 032" Aluminum
Installation Instructions
FL23953 RO II FL 23953 Petersen Alumin m Detail Bindr
Verified By: Locke Bowden, P.E. 49704
Created by Independent Third Party: Yes
Evaluation Reports
FL23953 RO AE FL 23953 PETERSEN ALUM REPORT
complete-SS.pdf
Created by Independent Third Party: Yes
.032" Aluminum over 1/2" min. Plywood
Installation Instructions
FL23953 RO II FL 23953 Petersen Aluminum Detail Binder
SS.pdf
Verified By: Locke Bowden, P.E. 49704
Created by Independent Third Party: Yes
Evaluation Reports
FL23953 RO AE FL 23953 PETERSEN ALUM REPORT
comp
le e SS.Rdf
Created by Independent Third Party: Yes
14.5" wide x .032" (min) aluminum Large Precision Tile Panel
Installation Instructiions
FL23953 RO II FL 23953 Petersen Aluminum Detail Binder
SS.pdf
Verified By: Locke Bowden, P.E. 49704
Created by Independent Third Party: Yes
Evaluation Reports
FL23953 RO AE FL 23953 PETERSEN ALUM REPORT
complete-SS.pdf
Created by Independent Third Party: Yes
14.5" wide x 24 ga. (min) steel Large Precision Tile Panel
Installation Instructions
FL23953 RO II FL 23953 Petersen Aluminum Detail Binder
�S. pdf
Verified By: Locke Bowden, P.E. 49704
Created by Independent Third Party: Yes
Evaluation Reports
FL23953 RO AE FL 23953 PETERSEN ALUM REPORT
complete-SS.pdf
Created by Independent Third Party: Yes
https:llfloridabuilding.org/pr/pr_app_df.aspx?param=wGEVXQwtDquSI Bu8CAEmBKm5WPFwLdekOBUlbh8uCEfxrZfkBEgzow%3d%3d 2/5