Loading...
HomeMy WebLinkAbout9-16-20 GIBENY-R-2-SIGNEDHAND RAI L 2.5"—RETURNS 2.5"—M.D_ ; POOL SPECIFICATIONS MAX. WIDTH 14' MAX.LENGTH 28' PERIMETER 84' AREA 392 sq.ft. DEPTH 3'0" - 60" ACCESS RIGHT ELEV. TOB TBD EXCAVATED DIRT HAUL RAISED BEAM N/A TILE 6x6 STEP EDGE 2x6 COPING EDGE OVERPOUR TANK N/A INTERIOR FINISH GEM SWIMOUT (1) 8' LADDER N/A HANDRAIL YES GRAB RAIL NO FILTER JANDY CS CART. TIMECLOCK N/A CIRC. PUMP JANDY FLOPRO VS 1.85 HP POOL DRAIN 3"x32" CHANNEL DRAIN MODEL#CMP25506-320 POOL RETURNS 4 VAC. LINE (1)STUBOUT SKIMMER (1) CHLORINATOR TRUCLEAR FILL LINE N/A OVERFLOW N/A WATERFEATURE NO LIGHTS POOL (2) COLOR LED ELECTRIC BY TBD TRANSFORMER YES J. BOX YES HEATER NO SIZE XXX btu GAS TYPE N/A TANK N/A HOOKUP BY N/A DELUXE CLEANING KIT YES PATIO CONC & SPRAY DECK SQ FT ±424 TERMITE YES DONE BY BUGMAN PORCH PATIO N/A DECK DRAIN 32' PLANTERS NO APPROX. GALLONS 13,100 G.P.M. -- TURNOVER HR. MIN. SCREEN ENCLOSURE YES CHILD BARRIER CHILD BARRIER FENCE C/) JOB INFORMATION: C/") w U COAST LIFE POOLS LLC Q � I GIBNEY RESIDENCE 771 SOLAZ AVE PORT ST LU IE, FL Digitally signed by Marvin R Marvin R Rodgers DN: c=US, o=Unaffiliated, ou=A014100000001725DB6 Rodgers Rodgers 8119, cn=Marvin R Rodgers Date: 2020.11.0418:55:58 -05,00, M. RANDALL RODGERS, P.E. FL License No. 68212 1801 Hazelwood Drive Ft Pierce, FL 34982 (772)201-1634 ***ELECTRIC NOT INCLUDED*** FBC 2017 Compliance NEC 2017 Compliance PREPARED BY: SHEET: STEVE HORST 1 DRAFTING & DESIGN SERVICES 3 (772)201-7846 horst.steve@yahoo.com —Pool construction complies with FBC 2017, ANSI -7, ANSI -15 —Water Velocity—Max 8ft/sec as per FBC 2017—R4501.6.3 —Pool Barrier to comply with Section R4501.17 -6th edition FBC —Skimmers comply with FBC 2017—R4501.21.2 —Soil bearing capacity assumed 2,000psi @95% compaction —Equipment Foundation 3'x7' conc. slab min 3.5" thick pour in place or approved Hurricane Rated precast equipment pads a; TREADED GREATER THAN 6' ADD PLUG s ` (1)#3 COVE BAR @6" O.C. GRAVEL BED TO PUMP — TYP. WALL SECTION & WELL POINT (NO SCALE) 8„ (2) #3 REBAR OR (1) #5 REBAR • FOOTER DETAIL (NO SCALE) c0 Y" PER FT. MIN SLOPE NOTE: REMOVE GRATE & y r WELL POINT PLUG FROM MAIN 16 gpm DRAIN & ATTACH AUX. PUMP LINE WHEN EMPTYING POOL OVERPOUR OR CAP TILE WHERE APPUCABLE , :• `' ` '!' • s� WHEN PROVIDEDDECK 6"x6" TILE 37 gpm 0.08' 50 GRATE SHALL SHALL BE AT 20" MAX BELOW THE lvo� 62 4" SLAB BE SECURED IN INTERIOR2500 m HORIZONTAL INSTALL FIBER MIX PLACE SO FINISHP. WATERLINE WALL -3,000 PSI GUNITE THAT TOOLS 0,09' LINT STRAINER SWALLS HALL 7 i NOT STEEL @ 12" 0/C E.W. ARE REQUIRED 0.04' 181 gpm Ppp` REtURNS FOR REMOVAL 234 ��i. a�� ii. asp #8 COPPER STEEL–TEX FORM gpm REASONABLYEUNIFORMBAND ¢ 534 OR KRAFT WALL 0.02' 6" TYP. FLOOR COMPLYWITH H ARTICLES 5.6.1 THE SLOPE OF THE FLOOR FROM END WALL THE SHARDS N TRENCH DRAIN 3,000 PSI GUNITE #3 @ 12" O.C.B.W. NOTE: FOR DEPTHS a; TREADED GREATER THAN 6' ADD PLUG s ` (1)#3 COVE BAR @6" O.C. GRAVEL BED TO PUMP — TYP. WALL SECTION & WELL POINT (NO SCALE) 8„ (2) #3 REBAR OR (1) #5 REBAR • FOOTER DETAIL (NO SCALE) HYDRO–STATIC RELIEF DEVICE INSTALLED IN AREAS THAT EXCEED 1' WATER TABLE IN SHELL TRENCH DRAIN TO GRAVEL BED MAIN DRAIN POOL DETAIL (NO SCALE) OUTSIDE ANGLE OF REPOSE 6' AND FURTHER – 4" THICK WALLS W/#3 REBAR @12" O.C. EACH WAY 3' TO 6' – 6" THICK WALLS W/#3 REBAR @12" O.C. EACH WAY 0' TO 3' – 8" THICK WALLS W/#3 REBAR @12" O.C. EACH WAY 9 ft. 6 ft. J J J . d . � .. . d c0 #8 COPPER TO GRID r y r = 1730 RPM 16 gpm 0.14' 21 1 ROW OF WATERLINE TILE WHEN PROVIDEDDECK 1.5" 37 gpm 0.08' 50 .7 3'-0" WATERLINE SHALL BE AT 20" MAX BELOW THE PRESSURE GAUGES INSTALLED ON FILTER PUMP FOR FINAL INSPECTION 62 gpm CHLORINATOR FILTER 82 m HORIZONTAL INSTALL 2.5" PUMP W/ HAIR & MAX 6'_0" LIGHT WATERLINE 117 gpm 0,09' LINT STRAINER SWALLS HALL 7 i NOT STEEL @ 12" 0/C E.W. gpm 0.04' 181 gpm Ppp` REtURNS #3 SLOPE FLOOR SLOPES 6" THICK GREATER THAN 11 " 234 ��i. a�� ii. asp #8 COPPER 313 gpm REASONABLYEUNIFORMBAND ¢ 534 TO GRID 0.02' 1 712 COMPLYWITH H ARTICLES 5.6.1 THE SLOPE OF THE FLOOR FROM END WALL THE SHARDS N VERTICAL INSTALL SKIMMER THE TOWARDS THE DEEP AREA SHALL ON PUMP ON FILTER NOT EXCEED 1 FOOT IN 7 FOOT Vacuum (In Hg) X 1.13 Pressure (PSI) X 2.31 Feet Of Head Feet Of Head PoolBond PB -2008 pRPIN VWE Install in Plumbing T at least 3" Below pppV NER 3x32 c�� Vacuum Head + Pressure Head Water level in Return Piping.lnstall CNNNNEVpRPIN 23'-0" in sprinkler box for easy access 28'-0" = Total Dynamic Head SWIMOUTS WATER BOND DETAILS FOR PIPING SCHEMATIC TYPICAL SECTION THRU POOL (NO SCALE) (NO SCALE) NICHLESS LIGHT SYSTEM HYDRO–STATIC RELIEF DEVICE INSTALLED IN AREAS THAT EXCEED 1' WATER TABLE IN SHELL TRENCH DRAIN TO GRAVEL BED MAIN DRAIN POOL DETAIL (NO SCALE) OUTSIDE ANGLE OF REPOSE 6' AND FURTHER – 4" THICK WALLS W/#3 REBAR @12" O.C. EACH WAY 3' TO 6' – 6" THICK WALLS W/#3 REBAR @12" O.C. EACH WAY 0' TO 3' – 8" THICK WALLS W/#3 REBAR @12" O.C. EACH WAY 9 ft. 6 ft. J J J . d . � .. . d c0 CO r y r MISC. NOTES 1. ALL STEPS AND SWIMOUT BENCH EDGES WILL HAVE 2x6 CAPTILE BORDER OF OPPOSITE COLOR OF GEM FINISH FOR VISIBILITY 2. HANDHOLD TO BE INSTALLED ARE WHERE DECK RAISED +6" ABOVE POOL rol 3 ft. O6_ EXCAVATION INTO THE ANGLE OF REPOSE IS ALLOWABLE PROVIDED: SHORING IS INSTALLED AT EXCAVATION AND SHORING SHOULD BE PCS SUFFICIENT TO SECURE SOILS FROM EROSION OR SETTLEMENT * NO UNDERMINING OCCURS OR ENGINEER APPROVED IF ANY DOES * COMPACTION TEST OF THE BACKFILLED MATERIAL ARE PROVIDED PRIOR TO THE POURING OF THE PATIO N WATERLINE N X a o OO fV 4a � Q o a< a 2Ld A- N d Ld 4 a . a. 16" MIN(TYP) STEP DETAILS 1. TREAD IS MIN OF 10" WIDE. 2. BOTTOM & TOP RISERS MAY VARY IN HEIGHT 3. RISER NOT GREATER THAN 12" EXCEPT BOTTOM STEP WHERE DEPTH IS 4' OR GREATER 4. ALL STEPS TO BE SOLID GUNITE 3000 P.S.I. 5. SUN SHELF CAN BE DESIGNED AS 1ST STEP. 6. A BENCH CAN BE DESIGNED AS 2ND STEP. POOL LIGHT JUCTION BOX YARD BY Z_ co POOL PATIO EQUIPMENT WATER LEVEL Z – 12 VAC FROM UNDERWATER ;: ;: POWER SUPPLY LIGHT SIZE AS DETERMINED BY LICENSED ELECTRICIAN POOL FINISH 1" PVC SCHEDULE 40 PVC SLEEVE CONDUIT NO BONDING OR GROUND REQUIRED NICHLESS UNDERWATER LIGHT DETAIL (NO SCALE) CUSTOM MOLDED PRODUCTS INC. SINGLE CHANNEL DUAL OUTLET PER FRC4501.6.6 COMPLIANT WITH 2017 FLORIDA BUILDING CODE LISTED TO ASME/ANSI A112.19.8 CMP 25506-32X VGB COMPLIANT 32" CHANNEL DRAIN 32" CHANNEL DRAIN AND SUMP 5" POOL 25506-320-000 *THREE 2" SOCKET x 2.5" SPIGOT PORTS *DEBRIS GUARD INCLUDED *38.79in? OPEN AREA *IAMPO LISTED FLOW RATES *WHITE PVC BODY *COVER GOES OVER BODY TO GIVE FINISHED LOOK TO PUMP The maximum flow rating for this suction fitting with the center port plugged and outer ports open is 308 GPM (floor) and 212 GPM (wall) when using 2.5" plumbing and 268 GPM (floor) and 192 GPM (wall) when using 2" plumbing. The maximum flow rating for this suction fitting with the outer ports plugged and the center port open is 200 GPM (floor) and 168 GPM (wall) when using 2.5" plumbing and 184 GPM (floor) and 176 GPM (wall) when using 2" plumbing. VSFHP185DV2A Performance Curves 3450 RPM 3 = 3000 RPM 2750 RPM E _ 2400 RPM o= = 1730 RPM 16 = 600RPM ' 111111111 I� 11111-1111 IIIIIIIII I CIRCULATION PUMP I IIIIIIIII IIIIIIIII IIIIIIIII IIIIIIIIIIIII_ IIIIIIIII _IIIIIIIII IIIIIIIII IIIIIIIII IIIIIIIII isu ieu Flow Rate, Gallons Per M to (GPM) LOW 43 GPM � HIGH 92 GPM z TREADS TO BE N SLIP RESISTANT CROSS BRACE CONCRETE PATIO BOND TO ANCHOR �mmir 0 5 PAVER PATIO \: 1 x301 CONIC. FOOTINGBARS ■ #8 GROUND I� ■ STEPS BONDING DETAIL for LADDER and/or RAIL (NO SCALE) (NO SCALE) Pipe Size 6 fps 8fps 1" 16 gpm 0.14' 21 gpm 0,23' 1.5" 37 gpm 0.08' 50 gpm 0.14' 2" 62 gpm 0,06' 82 m 0,10' 2.5" 88 gpm 0,05' 117 gpm 0,09' 3" 136 gpm 0.04' 181 gpm 0.07' 4" 234 gpm 0.03' 313 gpm 0.05' 6" 534 gpm 0.02' 1 712 gpm 0,03' Determine System Flow Rate: Minimum Flow Rate Required: 35 qpm per skimmer 1. Calculate Pool Volume: ___XXX --- ft— XX__x 7.48(gal/Ft) _---XXXXX__gal (Surface Area) (Average Depth) (Volume in gallons) 2. Determine Flow Rate: ___ 13,100 al 345 = 43 ----+--_XXX = XXX (Volume) (Turnover Minutes) (Pool Flow Rate) (Feature Flow Rate) (System Flow Rate) Determine Pipe Sizes: Trunk Piping to be--2.5—inch to keep velocity @ 8 fps max. at_ - 1 _gpm Maximum System Flow Rate. Return Piping to be --2.5 inch to keep velocity @ 8 fps max. at— 117—gpm Maximum System Flow Rate. Main Drain Cover(___SEE _ABOVE ---- ) System Flow Rate must not exceed approved cover flow rate. (Make and Model) See Engineering Page for Drain Configuration Pump Model PENTAIR INTELLIFLO H.P. 3 Total H.P.=H.P.x service factor.1 H.p. or more must be 2 speed or variable speed Filter Make PENTAIR C&C Size 150 Filter min. area based on 6hr. turnover flow rate pool gal. 1360 min. = Flow Rate Divide G.P.M. by Cartridge = .375 or Sand =15 or D.E. = 2 Time Controller make ON PUMP Model N A Controls must operate a minimum of two speeds. Thu hinher .Henri n,mrrirlo i. nnf fn nvnneri nne nnrmnl ounlo nr 9A hre urhinheuer ie Inco IOKVEl1\INO_N�li� COAST LIFE POOLS LLC GIBNEY RESIDENCE 771 SOLAZ AVE PORT ST LUCIE, FL M. RANDALL RODGERS, P.E. FL License No. 68212 1801 Hazelwood Drive Ft Pierce, FL 34982 (772)201-1634 ***ELECTRIC NOT INCLUDED*** PREPARED BY: SHEET: STEVE HORST 2 DRAFTING & DESIGN SERVICES 3 (772)201.7846 horst.steve@yahoo.com