HomeMy WebLinkAboutENGINEERING DIRECTORY OF PAGES � SCOPE OF WORK P-148891 PV-1 PROJECT SUMMARY T THIS PROJECT INVOLVES THE INSTALLATION OF A PV 2 SITE PLAN (!� PHOTOVOLTAIC POWER SYSTEM.SOLAR PANELS WILL BE r- RACKED USING A PREENGINEERED RACKING SYSTEM.THE PV-3 SINGLE-LINE DIAGRAM RACKED MODULES WILL BE ELECTRICALLY CONNECTED WITH DC TO AC POWER INVERTERS AND INTERCONNECTED TO THE PV-4 SAFETY LABELS LOCAL UTILITY USING MEANS AND METHODS CONSISTENT WITH THE RULES ENFORCED BY THE LOCAL UTILITY AND PV-5.1 ATTACHMENT PLAN 5.1 Z PERMITTING JURISDICTION. PV-5.2 ATTACHMENT PLAN 5.2 to PV 6 ATTACHMENT DETAILS THIS DOCUMENT HAS BEEN PREPARED FOR THE PURPOSE OF LV to DESCRIBING THE DESIGN OF A PROPOSED PV SYSTEM WITH PV-7 FIRE SAFETY PLAN `� ENOUGH DETAIL TO DEMONSTRATE COMPLIANCE WITH MODULE DATASHEET APPLICABLE CODES AND REGULATIONS.THE DOCUMENT C/) SHALL NOT BE RELIED UPON AS A SUBSTITUTE FOR > ARRAY WIRING BOX DATASHEET FOLLOWING MANUFACTURER INSTALLATION INSTRUCTIONS. C/ THE SYSTEM SHALL COMPLY WITH ALL MANUFACTURERS X DISCONNECT DATASHEET LISTING AND INSTALLATION INSTRUCTIONS,AS WELL AS ALL W M 0 APPLICABLE CODES.NOTHING IN THIS DOCUMENT SHALL BE J J Z INVERTER DATASHEET INTERPRETED IN A WAY THAT OVERRIDES THEM. LU CONTRACTOR IS RESPONSIBLE FOR VERIFICATION OF ALL LLJ MOUNTING SYSTEM DATASHEET CONDITIONS,DIMENSIONS,AND DETAILS IN THIS DOCUMENT. 0 111 Q MOUNTING SYSTEM ENGINEERING LETTER Q 0 UL 2703 GROUND AND BONDING CERTIFICATION ■e• Ave L Ave L Aue L Ave L Map data SYSTEM DETAILS Q p I� ANCHOR DATASHEET 00 LJJ NEW GRID-INTERACTIVE O 1 PLOT DESCRIPTION PHOTOVOLTAIC SYSTEM WITH NO PROJECT DETAILS PV-1 SCALE: NTS BATTERY STORAGE DC RATING OF SYSTEM 14.95KW 0 af O 3808 AVE L,FORT PIERCE,FL 34947 Lu PROPERTY ADDRESS US Treasure Coast AC RATING OF SYSTEM 11.04KW LL ZONING RESIDENTIAL IntornatforalAi port and 0 AC OUTPUT CURRENT 46.OA INVERTER Business Park St Lucie - -2- USE AND OCCUPANCY ONE-OR TWO-FAMILY DWELLING (S) 46 X ENPHASE IQ760US Of CLASSIFICATION GROUP(GROUP R3) MODULE APTOS SOLAR DNA-120 325 UTILITY COMPANY FLORIDA POWER&LIGHT CO "3 bo5 Ft Pierce Inlet (2)BRANCH OF 16 IQ7-60-2-US ELECTRICAL CODE 2014 NEC(NFPA 70) State Park ARRAY WIRING MICROINVERTERS Fort Pierce (1)BRANCH OF 14 IQ7-60-2-US FIRE CODE 2015 NFPA 1 rth ' MICROINVERTERS OTHER BUILDING 2017 FL BUILDING CODE CODES Anglev ms % ` INTERCONNECTION DETAILS SO NEW SUPPLY SIDE AC CONNECTION CONTRACTOR INFORMATION ] Fort Pierce POINT OF CONNECTION PER NEC 705.12(A) COMPANY EFFICIENT HOME SERVICES 4-r, Lawnwood Regional UTILITY SERVICE 120/240V 10 9416 INTERNATIONAL CT N,ST. Medical Center ADDRESS PETERSBURG,FL 33716 73 Indian River SITE DETAILS �tat�Call�ge PHONE NUMBER (844)778-8810 ASHRAE EXTREME LOW 0°C(32°F) CONTRACTOR ` PROJECT SIGNATURE a Fart Pierce �, ASHRAE 2%HIGH 33°C(91°F) .ff. =F South SUMMARY Map data 02v2v CLIMATE DATA SOURCE VERO BEACH MUNICIPAL AIRPORT (KVRB) 2 LOCALE DOC ID:148891-183637-1 This item has been signed and sealed by R Digitally signed WIND SPEED 160 MPH(ASCE7-10) DATE: 11/6/20 Reyes Manuel Ruiz Donate, 88991 PE on 11/6/2020 Reyes es PV-1 SCALE: NTS y y by Reyes Ruiz- RISK CATEGORY II CREATOR: using a Digital Signature. Donate WIND EXPOSURE B REVIEWER: Printed copies of this document are not considered Ruiz Date: CATEGORY REVISIONS signed and sealed and the SHA authentication code Donate 2020.11.06 must be verified on any electronic copies. 11:30:51 -05'00' 1 REYES M RUIZ DONATE PE#88991 AN ENGINEER LICENSED PURSUANT TO CHAPTER 471, CERTIFY THAT THE PV ELECTRICAL SYSTEM AND ELECTRICAL COMPONENTS ARE DESIGNED AND APPROVED USING THE STANDARDS CONTAINED IN THE MOST RECENT VERSION OF THE FLORIDA BUILDING CODE. PV_1 GENERAL NOTES P-148891 0 EQUIPMENT LIKELY TO BE WORKED UPON WHILE 1 ENERGIZED SHALL BE INSTALLED IN LOCATIONS THAT SATISFY MINIMUM WORKING CLEARANCES PER NEC 110.26. 2 CONTRACTOR SHALL USE ONLY COMPONENTS LISTED BY A NATIONALLY RECOGNIZED TESTING LABORATORY FOR THE INTENDED USE. CONTRACTOR IS RESPONSIBLE FOR FURNISHING ALL 2 EQUIPMENT,CABLES,ADDITIONAL CONDUITS, RACEWAYS,AND OTHER ACCESSORIES NECESSARY W FOR A COMPLETE AND OPERATIONAL PV SYSTEM. 3 c/) � 5 (N)AC COMBINER(Cl),OUTDOOR,OUTPUT CIRCUIT c/) OCONDUCTORS SHALL BE RUN IN PVC-40 CONDUIT fll� M OVER ROOF NO CLOSER THAN 0.5"ABOVE ROOF 6 SURFACE j J O2 (E)UTILITY METER,OUTDOOR SO L LJ W O3 (E)MAIN SERVICE PANEL(MSP),OUTDOOR Q (� O4 ROADWAY 1 0 W (N)VISIBLE,LOCKABLE,LABELED AC DISCONNECT O M O5 LOCATED WITHIN 10 FT OF UTILITY METER(SW1), U) OUTDOOR 0 (N)PROPOSED ROOF-MOUNTED PHOTOVOLTAIC ui O O6 ARRAY.3:12(14°)SLOPED ROOF,7 PV MODULES LL (BLACK FRAME,BLACK BACKSHEET),90°AZIMUTH (N)PROPOSED ROOF-MOUNTED PHOTOVOLTAIC 0 O7 ARRAY.3:12(14°)SLOPED ROOF,39 PV MODULES of 1 SITE PLAN (BLACK FRAME,BLACK BACKSHEET),180°AZIMUTH PV-2 SCALE: 1"=20' SITE PLAN DOC ID:148891-183637-1 DATE: 1116120 CREATOR: REVIEWER: REVISIONS PV-2 3M1 ��PVMODULE MODULES GENERAL ELECTRICAL NOTES P-1 48891 REF. QTY. MAKE AND MODEL PMAX PTC ISC IMP VOC VMP TEMP.COEFF.OF VOC FUSE RATING MICRO- PM1-46 46 APTOSSOLARDNA-120 325 325W 300 W 10.43A 9.93A 40 AV 32.7V -0.123V/°C(-0.31%/°C) 20A UTILITY HAS 24 HR UNRESTRICTED ACCESS TO ALL I - I - _ INVERTER 1 PHOTOVOLTAIC SYSTEM COMPONENTS LOCATED AT THE Q 0 INVERTERS SERVICE ENTRANCE. REF. QTY. MAKE AND MODEL AC VOLTAGE GROUND MAX OCPD RATING RATED POWER MAX OUTPUT CURRENT MAX INPUT CURRENT MAX INPUT VOLTAGE CEC WEIGHTED EFFICIENCY 1 161N 1 161N 1 141N Q Q 11-46 46 ENPHASE IQ7-60-2-US 240 V UNGROUNDED 240 W 1.0 A 15.0 A 48V 97.0% 2 MODULES CONFORM TO AND ARE LISTED UNDER UL 170 3. BRANCH BRANCH BRANCH PASS-THRU BOXES AND COMBINERS CONDUCTORS EXPOSED TO SUNLIGHT SHALL BE LISTED AS + + + �� REF. QTY. MAKE AND MODEL I RATED CURRENT MAX RATED VOLTAGE 3 SUNLIGHT RESISTANT PER NEC ARTICLE 30 0 .6(C)(1)AND Cl 1 ENPHASE Q AGGREGATOR OR EQUIV. 48A 240 VAC ARTICLE 310 .10 (D). DISCONNECTS OCPDS CONDUCTORS EXPOSED TO WET LOCATIONS SHALL BE REF. I QTY.I MAKE AND MODEL I RATED CURRENT I MAX RATED VOLTAGE REF. QTY. RATED CURRENT MAX VOLTAGE SW1 1 EATON DG222NRB OR EQUIV. 60 A 240 VAC Fi-3 3 20 A 240 VAC 4 SUITABLE FOR USE IN WET LOCATIONS PER NEC ARTICLE J L - F4-5 1 z 1 60 A 240 VAC 310 .10 (C). AC COMBINER SYSTEM SUMMARY NOTES ui 1 F1 F2 F3 NVERTERS PER BRANCH BRAN6CH 1 BRANCH 2 BRANCH 3 0 THE 4 690.DCA)ND1 . ATC CONNECTORS CONNECTO OFSH E ENPHASE COMPLY WITH 7-60-2C S AND ARE LISTED TO MEET REQUIREMENTS AS A DISCONNECT MEANS AS ALLOWED BY NEC GROUNDING NOTES �j r� 20 A 20 A 20 A Cl MAX AC CURRENT 16A 16A 14A ALL EQUIPMENT SHALL BE PROPERLY GROUNDED PER THE \r MAX AC OUTPUT 3,840 W 3,840 W 3,360 W A ENPHASE SYSTEM MEETS REQUIREMENTS FOR PHOTOVOLTAIC RAPID SHUTDOWN SYSTEM(PVRSS),AS PER NEC 690.12. 1 ARRAYSTCPOWER 14,950 w REQUIREMENTS OF NEC ARTICLES 250 &690 ARRAY PTC POWER 13,780 W MICROINVERTER BRANCH CIRCUIT CONDUCTORS ARE MANUFACTURED ENPHASE Q CABLES LISTED FOR USE IN 20 A OR LESS CIRCUITS OF ENPHASE IQ PV MODULES SHALL BE GROUNDED TO MOUNTING RAILS 1 F4-5 PV SYSTEM MAX AC CURRENT 46A 0 MICROINVERTERS.THEY ARE ROHS,OIL RESISTANT,AND UV RESISTANT.THEY CONTAIN TWO 12 AWG CONDUCTORS OF TYPE THHN/THWN-2 DRY/WET AND USING MODULE LUGS OR RACKING INTEGRATED ui M L__ 60 A DISCONNECT MAX AC POWER OUTPUT 1 1,0 40 W CERTIFIED TO UL30 0 3 AND UL 970 3.THE CABLE'S DOUBLE INSULATED RATING REQUIRES NO NEUTRAL OR GROUNDED CONDUCTOR. J r SW1 DERATEDAC POWER OUTPUT 11,040W 2 GROUNDING CLAMPS AS ALLOWED BY LOCAL JURISDICTION. O Lu LL_ 1 )60 A ® UNGROUNDED SYSTEM DC CONDUCTORS SHALL BE COLOR-CODED AS FOLLOWS.DC POSITIVE SHALL BE RED(OR MARKED RED)AND DC NEGATIVE SHALL BE ALL OTHER EXPOSED METAL PARTS SHALL BE GROUNDED 1 2 BLACK(OR MARKED BLACK) 1 USING UL-LISTED LAY-IN LUGS. Q 1 (20 0 A MSP W/20 0 A MCB) ALL METAL ENCLOSURES,RACEWAYS,CABLES AND EXPOSED NONCURRENT-CARRYING METAL PARTS OF EQUIPMENT SHALL BE GROUNDED TO EARTH AS INSTALLER SHALL CONFIRM THAT MOUNTING SYSTEM HAS a0U/ REQUIRED BY NEC 250.4(B)AND PART III OF ARTICLE 250 AND EQUIPMENT GROUNDING CONDUCTORS SHALL BE SIZED ACCORDING TO NEC 690.45(A).THE LL 1 GROUNDING ELECTRODE SYSTEM SHALL ADHERE TO NEC 690.47AND NEC 250.169.THE DC GROUNDING ELECTRODE SHALL BE SIZED ACCORDING TO NEC BEEN EVALUATED FOR COMPLIANCE WITH UL 2 70 3 O Lu 00 I LOADS 2 50.166 AND I NSTALLED IN COMPLIANCE WITH NEC 2 50.64. 3 "GROUNDING AND BONDING"WHEN USED WITH PROPOSED p M ,4-01- © MAX DC VOLTAGE OFPV MODULE IS EXPECTED TOBE43.2VAT0°C(0°C-25°C)X-0.123V/C+40.iV=43.2V). PV MODULE. CJ) }_ All Q 4 ALL GROUNDING SYSTEM COMPONENTS SHALL BE LISTED C)- A PV SYSTEM DISCONNECT SHALL BE A VISIBLE KNIFE-BLADE TYPE DISCONNECT THAT IS ACCESSIBLE AND LOCKABLE BY THE UTILITY.THE DISCONNECT SHALL FOR THEIR PU RPOSE LLJ Q UTILITY METER BE LOCATED WITHIN 10 FT OF UTILITY METER.DISCONNECT SHALL BE GROUPED IN ACCORDANCE WITH NEC 230.72. IF THE EXISTING MAIN SERVICE PANEL DOES NOT HAVE A LL- KWHR 240 I120 V 1�W � AC ® POINT-OF-CONNECTION IS ON THE SUPPLY SIDE OF SERVICE DISCONNECT,AT A LOCALLY-APPROVED CONNECTION POINT,USING LOCALLY-APPROVED VERIFIABLE GROUNDING ELECTRODE, IT IS THE GEC METHODS AND HARDWARE,IN COMPLIANCE WITH NEC 70 5.12(A). 5 CONTRACTOR'S RESPONSIBILITY TO INSTALL A CONDUCTOR AND CONDUIT SCHEDULE W/ELECTRICAL CALCULATIONS SUPPLEMENTAL GROUNDING ELECTRODE. CONDUIT/ CURRENT-CARRYING TEMP.CORR. FILL CONT. MAX.CURRENT BASE DERATED TERM. AMP.@TERM. AC SYSTEM GROUNDING ELECTRODE CONDUCTOR(GEC) D TYPICAL CONDUCTOR CABLE CONDUCTORS NCONDUIT/ OCPD EGC FACTOR FACTOR CURRENT (125%) AMP. AMP. TEMP.RATING TEMP.RATINGCABLE 6 SHALL BE A MINIMUM SIZE#8AWG WHEN INSULATED,#6AWG 6 AWG THWN-2, 0.75-DIA.PVC- 2 N/A 8 AWG THWN-2, 0.76(55°C) 1.0 46A 57.5A 95A 72.2A 75°C 85A IF BARE WIRE. COPPER COPPER EQUIPMENT GROUNDING CONDUCTORS SHALL BE SIZED 2 1 6 AWG THWN-2, 0.75'DIA.PVC- 2 60 A X 2 N/A 0.96(33°C) 1.0 46A 57.5A 95A 91.2A 75°C 85A COPPER ACCORDING TO NEC ARTICLE 690 .45,AND BE A MINIMUM OF 7 #10 AWG WHEN NOT EXPOSED TO DAMAGE,AND#6AWG SHALL BE USED WHEN EXPOSED TO DAMAGE GROUNDING AND BONDING CONDUCTORS, IF INSULATED, 8 SHALL BE COLOR CODED GREEN,OR MARKED GREEN IF #4AWG OR LARGER SINGLE-LINE DIAGRAM PROJECT ID: 148891 DATE: 11/0 6/20 CREATED BY: SDT CHECKED BY: REVISIONS SINGLE-LINE DIAGRAM PV-3 SCALE: NTS Pv_ � SW1 -DISCONNECT EACH DISCONNECTING MEANS FOR LABELING NOTES P-148891 EATON DG222NRB O PHOTOVOLTAIC EQUIPMENT(SW1) O AC DISCONNECT(SW1) O AC SOLAR DISCONNECT(SW1) ALL 1 PLAQUES AND20 n N G REQUIRED N PA1 WILL BE INSTALLED AS REQUIRED. O O O O O ! WARNING ! LABELS,WARNING(S)AND MARKING SHALL COMPLY ELECTRIC SHOCK HAZARD.DO NOT TOUCH [MAXIMUM AC OPERATING CURRENT:46.OA WITH ANSI Z535.4,WHICH REQUIRES THAT DANGER, MSP-MAIN SERVICE PANEL TERMINALS.TERMINALS ON BOTH LINE AND MUM AC OPERATING VOLTAGE:240V PHOTOVOLTAIC AC DISCONNECT WARNING,AND CAUTION SIGNS USED THE STANDARD O LOAD SIDES MAY BE ENERGIZED IN THE OPEN 2 HEADER COLORS,HEADER TEXT,AND SAFETY ALERT POSITION. SYMBOL ON EACH LABEL.THE ANSI STANDARD 5 REQUIRES A HEADING THAT IS AT LEAST 50%TALLER NEC 690.17(E) NEC 690.54 NEC 690.13(B) THAN THE BODY TEXT,IN ACCORDANCE WITH NEC 110.21(B). ANY AC ELECTRICAL PANEL THAT IS FED BY W O SEE NOTE NO.4(SW1) O5 BOTH THE UTILITY AND THE PHOTOVOLTAIC A PERMANENT PLAQUE OR DIRECTORY SHALL BE SYSTEM(SW1,MSP) INSTALLED PROVIDING THE LOCATION OF THE SERVICE (/ 3 DISCONNECTING MEANS AND THE PHOTOVOLTAIC SYSTEM DISCONNECTING MEANS IF NOT IN THE SAME LOCATION IN ACCORDANCE WITH NEC 690.56(B). - EQUIPPED ! WARNING ! 1 M DUAL POWER SOURCE.SECOND SOURCE IS LABEL(S)WITH MARKING,"PHOTOVOLTAIC SYSTEM Lij WITH RAPID PHOTOVOLTAIC SYSTEM. EQUIPPED WITH RAPID SHUTDOWN,"SHALL BE LOCATED J —i 4 AT POINT-OF-INTERCONNECTION OR AT MAIN SERVICE W DISCONNECT THE LABEL SHALL HAVE 3/8"TALL NEC 690.12 AND NEC 690.56(C) NEC 705.12(D)(3) LETTERS AND BE REFLECTIVE WITH WHITE TEXT ON A > L u RED BACKGROUND < (� W J 000 — p M 0 O H LL- 0 SAFETY LABELS DOC ID:148891-183637-1 DATE: 11/6/20 CREATOR: REVIEWER: REVISIONS PV-4 ROOF PROPERTIES P-148891 ROOF MATERIAL COMPOSITION SHINGLE(1 LAYER) N SLOPE 3/12(14.0°) MEAN ROOF HEIGHT 12FT DECK SHEATHING 15/32"OSB RIDGE RIDGE CONSTRUCTION RAFTERS(2X4'S),241N OC I I I MODULE MECHANICAL PROPERTIES Lu �y� �� �y� �y� �y� W MODEL APTOS SOLAR DNA-120 325 w w DIMENSIONS(AREA) 66.31N X 39.41N X 1.41N(18.2 SQ FT) Q Q WEIGHT 41.9LB U W M MOUNTING SYSTEM PROPERTIES J J LIL- RAIL MODEL QUICK MOUNT PV QRAIL QMR-RL O j ANCHOR MODEL QUICK MOUNT PV QMLM(FLASHED), EAVE 0 1.01N AIR GAP00 FASTENING METHOD 3.5 INCH EMBEDMENT INTO RAFTERS J 00 CD W WITH(1)5/161N DIA.FASTENER O M 72.01N(ZONE 1) Cn MAX.ALLOW.RAIL SPAN 48.01N(ZONE 2) WIND ZONE I WIND ZONE II WIND ZONE III Q of 24.01N(ZONE 3) W O 72.01N(ZONE 1) LL- DISTANCE a IS EQUAL TO 10%OF THE BUILDING'S LEAST HORIZONTAL DIMENSION OR 40%OF THE MEAN ROOF HEIGHT,WHICHEVER IS SMALLER,BUT NOT LESS THAN 4%OF THE LEAST HORIZONTAL DIMENSION OR 3 FEET ACSE 7- MAX.MOUNT SPACING 48.OIN(ZONE 2) ( 24.01N(ZONE 3) 10).THESE SETBACKS ARE APPLIED TO THE BUILDING FOOTPRINT AND PROJECTED TO THE PLANES OF ROOF CORNERS,RAKES,HIPS,EAVES,MANSARDS,AND RIDGES OF ROOF FACES. 0 23.81N(ZONE 1) a=MAX(MIN(0.4*MEAN ROOF HEIGHT,0.1*LEAST HORIZONTAL DIMENSION), 0.04*LEAST HORIZONTAL DIMENSION,3 FT) MAX.ALLOW. 15.81N(ZONE 2) 4.8 FT=MAX(MIN(0.4*12.0 FT,0.1*68.7 FT), 0.04*68.7 FT,3 FT) CANTILEVER 7.91N(ZONE 3) GROUNDIROUNDING CER BONND NGNG AND TO UL27 3INTEGALG EQUIRE ENTSTIFIED 1 ATTACHMENT PLAN ORTHOGONAL PROJECTION V-5.1 SCALE: 3/32"= 1' DEAD LOAD CALCULATIONS LOAD QTY LBS TOTALLBS MODULES 39 41.9 1633.6 MICROINVERTERS 39 1.1 42.1 LINEAR FEET OF RAIL 262 FT 0.5 131.1 ANCHORS 74 1.0 75.5 MISC.HARDWARE 31.6 31.6 TOTAL ARRAY WEIGHT 1914.0 LBS ATTACHMENT AREA NAME QTY SQFT TOTAL SQFT PLAN MODULES 39 18.2 709.8 DOC ID:148891-183637-1 POINT LOAD(1914.0 LBS/74 ATTACHMENTS) 25.9 LBS DATE: 11/6/20 DIST.LOAD(1914.0 LBS/709.8 SQFT) 2.7 PSF CREATOR: REVIEWER: NOTES REVISIONS RAFTER LOCATIONS ARE APPROXIMATE.ACTUAL 1 LOCATIONS MAY DIFFER AND CONTRACTOR MAY NEED TO ADJUST MOUNT LOCATIONS.IN NO CASE SHALL THE MOUNT SPACING EXCEED"MAX.MOUNT SPACING" PV-5. 1 ROOF PROPERTIES P-148891 ROOF MATERIAL COMPOSITION SHINGLE(1 LAYER) Z SLOPE 3/12(14.0°) MEAN ROOF HEIGHT 11.3FT DECK SHEATHING 15/32"OSB RIDGE CONSTRUCTION RAFTERS(2X4'S),241N OC �- MODULE MECHANICAL PROPERTIES W MODEL APTOS SOLAR DNA-120 325 DIMENSIONS(AREA) 66.31N X 39.41N X 1.41N(18.2 SQ FT) WEIGHT 41.9LB U w � M L��lcc L u J J MOUNTING SYSTEM PROPERTIES y w RAIL MODEL QUICK MOUNT PV QRAIL QMR-RL Lij ANCHOR MODEL QUICK MOUNT PV QMLM(FLASHED), Q (� 1.01N AIR GAP 00 FASTENING METHOD 3.5 INCH EMBEDMENT INTO RAFTERS J 00 CD W WITH(1)5/161N DIA.FASTENER O M 72.01N(ZONE 1) Cn MAX.ALLOW.RAIL SPAN 48.01N(ZONE 2) of 24.01N(ZONE 3) EAVE 0 O 72.0IN(ZONE 1) LL MAX.MOUNT SPACING 48.01N(ZONE 2) ~ 24.01N(ZONE 3) Q 23.81N(ZONE 1) WIND ZONE I WIND ZONE 11 WIND ZONE III of MAX.ALLOW. 15.81N(ZONE 2) CANTILEVER 7.91N(ZONE 3) DISTANCE a IS EQUAL TO 10%OF THE BUILDING'S LEAST HORIZONTAL DIMENSION OR 40%OF THE MEAN ROOF HEIGHT,WHICHEVER IS SMALLER,BUT NOT LESS THAN 4%OF THE LEAST HORIZONTAL DIMENSION OR 3 FEET(ACSE 7- GROUNDING AND INTEGRAL GROUNDING CERTIFIED 10).THESE SETBACKS ARE APPLIED TO THE BUILDING FOOTPRINT AND PROJECTED TO THE PLANES OF ROOF CORNERS,RAKES,HIPS,EAVES,MANSARDS,AND RIDGES OF ROOF FACES. BONDING TO UL 2703 REQUIREMENTS a=MAX(MIN(0.4'MEAN ROOF HEIGHT,0.1`LEAST HORIZONTAL DIMENSION), 0.04"LEAST HORIZONTAL DIMENSION,3 FT) DEAD LOAD CALCULATIONS 4.5 FT=MAX(MIN(0.4 11.3 FT,0.1 68.7 FT), 0.04 68.7 FT,3 FT) LOAD QTY LBS TOTAL LBS 1 ATTACHMENT PLAN ORTHOGONAL PROJECTION MODULES 7 41.9 293.2 PV-5.2 SCALE: 1/4"= 1' MICROINVERTERS 7 1.1 7.6 LINEAR FEET OF RAIL 59 FT 0.5 29.6 ANCHORS 26 1.0 26.5 MISC.HARDWARE 8.0 8.0 TOTAL ARRAY WEIGHT 364.9 LBS ATTACHMENT AREA NAME QTY SQFT TOTAL SQFT PLAN MODULES 7 18.2 127.4 DOC ID:148891-183637-1 POINT LOAD(364.9 LBS/26 ATTACHMENTS) 14.0 LBS DATE: 11/6/20 DIST.LOAD(364.9 LBS/127.4 SQFT) 2.86 PSF CREATOR: REVIEWER: NOTES REVISIONS RAFTER LOCATIONS ARE APPROXIMATE.ACTUAL 1 LOCATIONS MAY DIFFER AND CONTRACTOR MAY NEED TO ADJUST MOUNT LOCATIONS.IN NO CASE SHALL THE MOUNT SPACING EXCEED"MAX.MOUNT SPACING" PV-5.2 MOUNTING SYSTEM NOTES P-148891 FLASHING SHALL BE APPLIED IN ACCORDANCE WITH MANUFACTURERS'INSTRUCTIONS. IF THERE IS ANY CONFLICT BETWEEN WHAT IS DEPICTED HERE AND INSTRUCTIONS 2 PROVIDED BY A MANUFACTURER,THE MANUFACTURER'S INSTRUCTIONS SHALL SUPERCEDE. RAIL CLAMPING ZONE Lj Cn ti QMPV UNIVERSAL /-'' �' / MID CLAMP cf) ROOF FRAMING PV MODULE / QMPV QRAIL LIGHT J —i QMPV L-MOUNT Q LLJ (QMLM/QMLM ST) Q W U PV MODULE --� \` C oo W PV-6 0 W J 00 � COMP.SHINGLE SLIDE FLASHING 0 ROOFING UNDER THE 3RD c/) COURSE OF SHINGLESUJI 0 PV-6 ROOF UNDERLAYMENT ROOF FRAMING ROOF DECKING /� 0 ``�----" -LAGISTRUCTURAL SCREWS EMBEDDED INTO ROOF FRAMING (� A RACKING ELEVATION TRANSVERSE VIEW C ATTACHMENT DETAIL TRANSVERSE VIEW PV-6 SCALE: NTS PV-6 SCALE: NTS PV MODULE PV-6 QMPV UNIVERSAL MID CLAMP PV MODULE / QMPV UNIVERSAL END CLAMP \/ ' QMPV QRAIL LIGHT COMP.SHINGLE--,\ -- - -- QMPV L-MOUNT ATTACHMENT ROOFING ' (QMLM I QMLM-ST) QMPV QRAIL DETAILS LIGHT DOC ID:148891-183637-1 ROOF DECKING COMP.SHINGLE \ - j INSTALL FLASHING DATE:11I6I20 ROOFING ROOF UNDERLAYMENT �� CREATOR: ROOF FRAMING SPACING I ATTACHMENT SPAN - ROOF FRAMING ROOF DECKING LAGISTRUCTURAL SCREWS REVIEWER: ROOF FRAMING '----"'� EMBEDDED INTO ROOF REVISIONS FRAMING B RACKING ELEVATION LONGITUDINAL VIEW D ATTACHMENT DETAIL LONGITUDINAL VIEW PV-6 SCALE: NTS PV-6 SCALE: NTS PV-6 N GENERAL NOTES P-148891 ROOF ACCESS POINTS SHALL BE DEFINED AS AREAS WHERE FIRE DEPARTMENT LADDERS ARE NOT PLACED 1 OVER OPENINGS(WINDOWS OR DOORS),ARE LOCATED AT STRONG POINTS OF BUILDING CONSTRUCTION,AND ARE IN LOCATIONS WHERE THEY WILL NOT CONFLICT WITH OVERHEAD OBSTRUCTIONS(TREE LIMBS,WIRES, OR SIGNS).(NFPA 1 11.12.2.2.1.3) 2 PHOTOVOLTAIC MODULES SHALL BE LOCATED IN A MANNER THAT PROVIDES A 3 FT WIDE CLEAR ACCESS 2 PATHWAY FROM THE EAVE TO THE RIDGE OF EACH ROOF SLOPE WHERE THE PHOTOVOLTAIC MODULES LLJ 2 ARE LOCATED.THE ACCESS PATHWAY SHALL BE 3 4 LOCATED AT A STRUCTURALLY STRONG LOCATION OF (/) THE BUILDING,SUCH AS A BEARING WALL,EXCEPT WHERE ADJOINING ROOF PLANES PROVIDE A 3 FT WIDE (/ 2 CLEAR ACCESS PATHWAY.(NFPA 1 11.12.2.2.2.1.1) PHOTOVOLTAIC MODULES SHALL BE LOCATED NO LijM fi CLOSER THAN 1-1/2 FEET TO A HIP OR VALLEY IF J MODULES ARE TO BE PLACED ON BOTH SIDES OF THE LLI 3 3 HIP OR VALLEY.WHERE MODULES ARE LOCATED ON ONLY ONE SIDE OF A HIP OR VALLEY OF EQUAL LENGTH, > w THE PHOTOVOLTAIC MODULES SHALL BE ALLOWED TO Q (� BE PLACED DIRECTLY ADJACENT TO THE HIP OR 00 VALLEY.(NFPA 1 11.12.2.2.2.1.3) J (D LLI 7 7 4 PHOTOVOLTAIC MODULES SHALL BE LOCATED NO LESS O M THAN 3 FT BELOW THE RIDGE.(NFPA 1 11.12.2.2.2.2) Cn 2 Lu O O 3.0 FT.WIDE FIRE ACCESS PATHWAY,PER NFPA 1 LL 4 3 11.12.2.2.2.1.3 AND NFPA 1 11.12.2.2.2.1.2 O2 ROOF ACCESS POINT 0 1 FIRE SAFETY PLAN O 3.0 FT.WIDE SMOKE-VENTILATION SETBACK,PER NFPA of PV-7 SCALE: 1"=20, 1 11.12.2.2.2.2 PV MODULES INSTALLED ON ROOF WITH QUICK MOUNT PV QRAIL MOUNTING SYSTEM.THE MOUNTING SYSTEM O4 IS UL 1703 CLASS A FIRE RATED ON A 3/12 SLOPED ROOF WHEN INSTALLED WITH TYPE 1 OR 2 MODULES. THE APTOS SOLAR DNA-120 325 IS TYPE 1. O5 ROADWAY O1.5 FT.WIDE FIRE ACCESS PATHWAY,PER NFPA 1 11.12.2.2.2.1.3 AND NFPA 1 11.12.2.2.2.1.2 O3.0 FT.WIDE FIRE ACCESS PATHWAY,PER NFPA 1 11.12.2.2.2.1.1 TOTAL PLAN VIEW ARRAY AREA IS 833.0 SQ.FT,WHICH 8 REPRESENTS 19.6%OF TOTAL PLAN VIEW ROOF AREA (4260.4 SQ.FT) THIS SYSTEM UTILIZES MICROINVERTERS.THERE ARE FIRE SAFETY 9 NO DC OR INSIDE THE BUILDING. PLAN OF THE ARRAY PERIMETER PLAN 10 CABLES,WHEN RUN BETWEEN ARRAYS,SHALL BE DOC ID:148891-183637-1 ENCLOSED IN CONDUIT. DATE: 1116120 CREATOR: REVIEWER: REVISIONS PV-7 DNA- ] 20/ALL - BLACK DESIGN DNA - ] 20 330W 1325W 1320W BLACK FRAME, BLACK BACKSHEET aptos HIGH EFFICIENCY, HALF-CUT CELL PANEL solar technology ELECTRICAL • 1 ' DNA-120-MF23-32OW DNA-120-MF23-325W DNA-120-MF23-33OW Q STCrated output Pmpp(W) 320 325 330 n[dent n'ptl•1 ppp Yllrn• f0 3]9.9W Module Efficiency 18.96% 19.25% 19.54% nYnen�..�Wn,• Open Circuit Voltage Vv°�(V) 39.92 40.10 40.27 - neeknme.-5•pwmr f%.9 Short Circuit Current Ise(A) 10.35 10.43 10.51 nwn.-d-.00 WW 129.9 Rated Voltage Vmmp(V) 32.51 32.71 32.91 n[nent nraa•MW— 63sw Rated Current Immp(A) 9.84 9.93 10.02 Standard Test Conditions for front-face of panel: 1000 W/m 2,25°C,measurement uncertainty<3°i° TEMPERATURE COEFFICIENTS Temperature Coefficients Pmpp -0.40%/°C • Temperature Coefficients Isc +0.046%/'C Cell Type Monocrystalline Temperature Coefficients V 0.306%/°C Glass Low Iron,Tempered Maximize Energy Production Normal Operating Cell Temperature(NOCT) 45"C Frame Anodized Aluminum Alloy High-efficiency, Half-cut cell panel TEST OPERATING CONDITIONS Junction Box IP67 Maximum Series Fuse 20A Dimension 1684 x 1002 x 35mm - • Output Cable 4mm2(EU)12AWG, Advanced technology boosts Maximum System Voltage 1,500 VDC(UL&IEC) p 39.37in(1000mm) power generation Maximum Load Capacity(Per 5,400PA Snow Load Weight 41.91bs.(19kg) UL1703) 175mph Wind Rating Resilient in extreme weather conditions Fire Performance Class Class C/Type 1 Cable Length 1200mm b4UO Pa snow load q PACKAGING CONFIGURATION Number of Modules per Pallet 30 design f• pristine 84.8% Number of Pallets per 40ft HQ 26 :0 Container Pallet Dimensions(mm) 1720X 1140 X 1140 25 year waranty Aptos Warranty 0 Standard Warranty _ Pallet weight(kg) 620 O • • reliability 9 Container weight(kg) 16120 Factory Certifications E E £ e Our DNA Half-cut Cell Series impressively combines PRODUCT CERTIFICATIONS advanced technologies to maximize performance. Our patented DNA, Dual Nano Absorber, technology allows for 9001 14001 18001 G soo panel operate at high LISTED performance • temperatureenvironments. 3140 De La Cruz Blvd.,Ste,200 Santa Clara,CA 95054 www.aptossolar.com I info@aptossolar.com 1002mm 35mm 952mm • • • • DNA-120-MF23-XXXW ' • • • info@aptossolar.comAptos Solar Technology reserves the right to make specification changes without notice RESIDENTIAL I COMMERCIAL Data Sheet Enphase IQ 7 and IQ 7+ Microinverters Enphase Microinverters INPUT DATA(DC) IQ7-60-2-US/IQ7-60-B-US IQ7PLUS-72-2-US/IQ7PLUS-72-B-US Region:AMERICAS Commonly used module pairings' 235 W-350 W+ 235 W-440 W+ Module compatibility 60-cell PV modules only 60-cell and 72-cell PV modules Maximum input DC voltage 48 V 60 V Peak power tracking voltage 27 V-37 V 27 V-45 V Operating range 16 V-48 V 16 V-60 V Min/Max start voltage 22 V/48 V 22 V/60 V Max DC short circuit current(module Isc) 15 A 15 A Enphase The high-powered smart grid-ready Overvoltage class DC port II II Enphase IQ 7 Micro- and Enphase IQ 7+Micro- DC port backfeed current 0 A 0 A Q 7 a n d I Q 7 y simplify p PV array configuration 1 x 1 ungrounded array;No additional DC side protection required; ♦ dramatically sim lif the installation process while AC side protection requires max 20A per branch circuit achieving the highest system efficiency. OUTPUT DATA(AC) IQ 7 Microinverter IQ 7+Microinverter Microinverters Peak output power 250 VA 295 VA Part of the Enphase IQ System,the IQ 7 and Maximum continuous output power 240 VA 290 VA IQ7+ Microinvertersinte rate with the Enphase Nominal(L-L)voltage/rangez 240V/ 208V/ 240V/ 208V/ 9 P 211-264 V 183-229 V 211-264 V 183-229 V IQ Envoy'"', Enphase IQ BatteryTM,and the Enphase Maximum continuous output current 1.0 A(240 V) 1.15 A(208 V) 1.21 A(240 V) 1.39 A(208 V) M Nominal frequency 60 Hz 60 Hz Enlighten mOnitOCing and analySlS software. Extended frequency range 47-68Hz 47-68Hz IQ Series Microinverters extend the reliability AC short circuit fault current over 3 cycles 5.8 Arms 5.8 Arms Maximum units per 20 A(L-L)branch circuit' 16(240 VAC) 13(208 VAC) 13(240 VAC) 11 (208 VAC) standards set forth by previous generations and Overvoltage class AC port III III undergo over a million hours of power-on testing, AC port backfeed current 0 A 0 A Power factor setting 1.0 1.0 enabling Enphase to provide an industry-leading Power factor(adjustable) 0.85leadin9���0.85 lagging 0.85leadin9���0.85lagging Warranty of up to 25 years. EFFICIENCY @240 V @208 V @240 V @208 V Peak efficiency 97.6% 97.6% 97.5% 97.3% CEC weighted efficiency 97.0 i 97.0 i 97.0 i 97.0 i MECHANICAL DATA Ambient temperature range -400C to+65°C Relative humidity range 4%to 100%(condensing) Easy to Install Connector type(IQ7-60-2-US&IQ7PLUS-72-2-US) MC4(or Amphenol H4 UTX with additional Q-DCC-5 adapter) Connector type(IQ7-60-B-US&IQ7PLUS-72-B-US) Friends PV2(MC4 intermateable). Lightweight and simple Adaptors for modules with MC4 or UTX connectors: Faster installation with improved,lighter two-wire cabling PV2 to MC4:order ECA-S20-S22 PV2 to UTX:order ECA-S20-S25 Built-in rapid shutdown compliant(NEC 2014&2017) Dimensions(WxHxD) 212 mm x 175 mm x 30.2 mm(without bracket) Weight 1.08 kg(2.38 Ibs) Productive and Reliable Cooling Natural convection-No fans Approved for wet locations Yes Optimized for high powered 60-cell and 72-cell*modules Pollution degree PD3 More than a million hours of testing Enclosure Class II double-insulated,corrosion resistant polymeric enclosure Class II double-insulated enclosure Environmental category/UV exposure rating NEMA Type 6/outdoor UL listed FEATURES p Communication Power Line Communication(PLC) Monitoring Enlighten Manager and MyEnlighten monitoring options. C Smart Grid Ready Both options require installation of an Enphase IQ Envoy. Disconnecting means The AC and DC connectors have been evaluated and approved by UL for use as the load-break Complies with advanced grid support,voltage and disconnect required by NEC 690. frequency ride-through requirements Compliance CA Rule 21 (UL 1741-SA) Remotely updates to respond to changing UL 62109-1,UL1741/IEEE1547,FCC Part 15 Class B, ICES-0003 Class B, grid requirements CAN/CSA-C22.2 NO.107.1-01 This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC-2014 and Configurable for varying grid profiles NEC-2017 section 690.12 and C22.1-2015 Rule 64-218 Rapid Shutdown of PV Systems,for AC Meets CA Rule 21 (UL 1741-SA) and DC conductors,when installed according manufacturer's instructions. U *The IQ 7+Micro is required to support 72-cell modules. 1.No enforced DC/AC ratio.See the compatibility calculator at https//enphase.com/en-us/support/module-compatibilit 2.Nominal voltage range can be extended beyond nominal if required by the utility. 3.Limits may vary.Refer to local requirements to define the number of microinverters per branch in your area. Iwo 11ore about Enphase offerings,visit enphase.com r- E N P H AS E To learn more about Enphase offerings,visit enphase.com E N P H A S E u @ 2018 Enphase Energy.All rights reserved.All trademarks or brands used are the property of Enphase Energy,Inc. 2018-11-19 - - QRak" — Fully Integrated Mounting and Racking System Fast, Simple Installation : It Just Clicks The QRail Series is a strong and versatile solar array mounting system that provides unrivaled benefits to solar Nick Technology" designers and installers. Combined with Quick Mount PV's industry-leading waterproof mounts, QRail offers a The universal mid and end clamps use patented QClick complete racking solution for mounting solar modules on any roof. technology to simply"click" into the rail channel and or remain upright, ready to accept the module. The Easily design array configurations with the QDesign software pre-assembled clamps fit virtually all module frames and application. Generate complete engineering reports and calculate require no extra hardware, eliminating pre-loading and a precise bill of materials for all the mounting, racking and reducing installation time. UNIVERSAL END CLAMP UNIVERSAL BONDED MID CLAMP accessories needed for a complete solar array. 1 40 2 3 2 clamps for modules from 2 clamps for modules from 30-45mm or38-50mm thick 30-45mm or38-50mm thick click! Comprehensive, One-Source Solution Installing is as easy as 1-2-3 QRail,together with Quick Mount PV's waterproof mounting products, provides the benefit of a single-sourced, QSplice" Technology seamlessly integrated rooftop installation that works with all roof types— composition/asphalt shingles, QRail's innovative internal QSplice installs in seconds, requiring no flat or curved tile, metal shingle, shake, slate and low slope roofs. The QRail system also works with any roof tools or screws. Simply insert QSplice into the rail and slide the other attachment system for maximum flexibility. rail onto create a fully structural, bonded splice.An external splice is Wo QSPLICE also available. Superior Strength and Versatility 1 2 " 3 QRail is engineered for optimal structural performance.The system WIN 00000W rj is certified to UL 2703, fully code compliant and backed by a 25-year HEAw Installs in seconds—no tools or hardware required warranty. QRail is available in Light, Standard and Heavy versions to 41 STANDARD match all geographic locations. QRail is compatible with virtually all STANDARD y Integrate E[ectrical Bonding LIGHT modules and works on a wide range of pitched roof surfaces. Modules The QRail system provides an integrated electrical bonding path, ensuring that all exposed metal arts and QRails come in two lengths— y p g g p g p p can be mounted in portrait or landscape orientation in standard or 168 inches(14 ft)and 208 inches(17.3 ft) the solar module frames are electrically connected.All electrical bonds are created when the components are shared-rail configurations. Mill and Black Finish installed and tightened down. ITEM DESCRIPTION QTY. THIS EDGE TOWARDS ROOF RIDGE NO. FLASHING, ROUNDED CORNERS, 9" X 12" X .040", .438" HOLE, 5052,1 1 _ MILL L-FOOT, 2" X 3.30" FOR .438" O.D. FASTENER, 2-1 /16" SLOT, 6061 - 2 T6/6005A-T61 , MILL 1 3 WASHER, SEALING, 5/16" ID X 3/4" OD, EPDM BONDED SS 1 4 LAG SCREW, HEX HEAD, 5/16" x 4", 18-8 SS 1 *5 STRUCTURAL SCREW, QMPV, T-30 HEX WASHER HEAD, 5/16" X 4-1 /2", 1 18-8SS M 12.00 *5 4 ( 4.20 ) * STRUCTURAL 3.00 3 SCREW AVAILABLE ON QMLM-ST 4.50 VERSIONS ONLY 2 9.00 I 2.00 I 0 .397 1 .00 T-- 2.09 3.30 .90 � 1 AVAILABLE IN MILL, AND BLACK FINISHES QuickMount PYi T040 TITLE: 3.54 T- 4.04 ( � 2.75 QMLM & QMLM-ST. L-MOUNT, ( 2.50 ) 2- 1 16" SLOT QMLM QMLM-S1 UNLESS OTHERWISE SPECIFIED: SIZE DRAWN BY: RAD REV DIMENSIONS ARE IN INCHES Q TOLERANCES: A DATE: 1/16/2018 / FRACTIONAL± 1/8 O PROPRIETARY AND CONFIDENTIAL TW PLACE DECIMAL -.19 THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF QUICK MOUNT PV. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE DO NOT SCALE DRAWING THREE PLACE DECIMAL ±.094 SCALE: 1:4 WEIGHT:1.0723 SHEET 1 OF 1 WRITTEN PERMISSION OF QUICK MOUNT PV IS PROHIBITED. COPYRIGHT©2016 QUICK MOUNT PV 5 4 3 2 1