HomeMy WebLinkAboutEnergy Codes�.t M .600A-97
FLORIDA ENERGY EFFICIENCY CODE
FOR BUILDING CONSTRUCTION
Florida Department of Community Affairs
Residential Whole Building Performance Method A
Project Name: SAVANNA CLUB,rPL�►N B1-1�0_P� Builder:
Address: Permitting Office: PORT ST-1-UGIt
City, State: Permit Number:
Owner: Jurisdiction Number: (501Z00
Climate Zone: Central
1.- New construction or existing
New _
12. Cooling systems
2. Single family or multi -family
Multi -family _
a. Central Unit
3. Number of units, if multi -family
1 _
4° Number of Bedrooms
1 _
b. N/A
5. Is this a worst case?
Yes _
6. Conditioned floor area (ft2)
1013 ft?
c. N/A
7. Glass area & type
_
a. Clear -,single pane
96.0 ft2 _
13. Heating systems
b. Clear - double pane
0.0 ft2 _
a. Electric Strip
c. Tint/other SC/SHGC - single pane
0.0 ft2
=d. Tint/other SC/SHGC -double pane
0.0 ft2
b. N/A
8. Floor types
a. Slab -On -Grade Edge Insulation
R=0.0, 84.0(p) ft _
c. N/A
' b. N/A
_
c. N/A
14. Hot water systems
9. Wall types
_
a. Electric Resistance
a. Concrete, Int Insul, Exterior
R=5.0, 336.0 ft2 _
b. Concrete, Int Insul, Adjacent
R=5.0, 309.0 ft2 _
b. N/A
c. N/A
d. N/A
_
c. Conservation credits
e. N/A
(HR-Heat recovery, Solar
10. Ceiling types
_
DHP-Dedicated heat pump)
a. Under Attic
R=19.0, 1013.0 ft2 _
15. HVAC credits
b. N/A
_
(CF-Ceiling fan, CV -Cross ventilation,
c. N/A
HF-Whole house fan,
11. Ducts
_
PT -Programmable Thermostat,
a. Sup: Con. Ret: Con. AH: Interior
Sup. R=4.2, 30.0 ft _
RB-Attic radiant barrier,
b. N/A
MZ-C-Multizone cooling,
MZ-H-Multizone heating)
Glass/Floor Area: 0.09 Total as -built points: 11611.00` PASS
Total base points: 12595.00
I hereby certify that the plans and specifications covered
by this calculation are in compliance with the Florida
Energy Code.
PREPARED BY:,4140'10-v6 . <If-S , •��"�-•
DATE: %S
I hereby certify that this building, 'as design ',d, is in
compliance with the Florida Enera, od .
OWNER/AGENT:
DATE:
Cap: 24.3 kBtu/hr
SEER: 10.00
Cap: 17.0 kBtu/hr
COP: 1.00
Cap: 40.0 gallons _
EF: 0.89
Review of the plans and
TA
TIfE STE,
specifications covered by this
compliance
O'e
= ; o
calculation indicates
'"'
with the Florida Energy Code.
Before construction is completed
"'�� "' .0
a
this building will be inspected for
compliance with. Section 553.908
C0
Florida Statutes.
D�5`�
we
BUILDING OFFICIAL:
DATE:
EnergyGaugeO (Version: FLRCNA-200)
4
FORM 60OA-97
FLORIDA ENERGY EFFICIENCY CODE
FOR BUILDING CONSTRUCTION
Florida Department of Community Affairs
Residential Whole Building Performance Method A
Project Name: SAVANNA CLUB PLAN�"OP Builder:
Address: Permitting Office:
City, State: Permit Number:
Owner: Jurisdiction Number:
Climate Zone: Central
1.
New construction or existing
New _
12. Cooling systems
2.
Single family or multi -family
Multi -family _
a. Central Unit
3.
_ Number of units, if multi -family
1 _
4.
Number of Bedrooms
1 _
b. N/A
5.
Is this a worst case?
Yes
6.
Conditioned floor area (ft2)
_
17QU Z
c. N/A
7.
Glass area & type
_
a. Clear - single pane
96.0 ft2 _
13. Heating systems
b. Clear - double pane
0.0 ft2 _
a. Electric Strip
c. Tint/other SC/SHGC - single pane
0.0 ft2 _
d. Tint/other SC/SHGC - double pane
0.0 ft2
b. N/A
8.
Floor types
.a. Slab -On -Grade Edge Insulation
R=0.0, 84.0(p) ft _
c. N/A
b. N/A
_
c. N/A
14. Hot water systems
9.
Wall types
_
a. Electric Resistance
a. Concrete, Int Insul, Exterior
R=5.0, 336.0 ft2 _
b. Concrete, Int Insul, Adjacent
R=5.0, 309.0 ft2 _
b. N/A
c. N/A
d. N/A
_
c. Conservation credits
e. N/A
(HR-Heat recovery, Solar
10. Ceiling types
_
DHP-Dedicated heat pump)
a. Under Attic
R-19.0, 1013.0 ft2 _
15. HVAC credits
b. N/A
_
(CF-Ceiling fan, CV -Cross ventilation,
c. N/A
HF-Whole house fan,
11. Ducts
_
PT -Programmable Thermostat,
a. Sup: Con. Ret: Con. AH: Interior
Sup. R=4.2, 30.0 ft _
RB-Attic radiant barrier,
b. N/A
MZ-C-Multizone cooling,
MZ-H-Multizone heating)
Glass/Floor Area: 0.09 Total as -built points: 11611.00 y PASS
Total base points: 12595.00
I hereby certify that the plans and specifications covered
by this calculation are in compliance with the Florida
Energy Code.
PREPARED BY:AWee. - SX4 r. er 1-vc.
DATE: Sep
I hereby certify that this building, as designed, is in
compliance with the Florida Ener o
OWNERIAGENT:
DATE: /o/
Cap: 24.3 kBtu/hr _
SEER: 10.00
Cap: 17.0 kBtu/hr _
COP: 1.00
Cap: 40.0 gallons
EF: 0.89
Review of the plans and
,sty sT
aTFo
specifications covered by this
o4 =
calculation indicates compliance
with the Florida Energy Code.
Before construction is completed
this building will be inspected for
tr
compliance with Section 553.908
icon`��;
Florida Statutes.
WF
BUILDING OFFICIAL:
DATE:
EnergyGauge® (Version: FLRCNA-200)
FORM 60OA-97
SUMMER CALCULATIONS
Residential Whole Building Performance Method A - Details
ADDRESS: , , , PERMIT #:
BASE
AS -BUILT
GLASS TYPES
.$8 X Conditioned X BSPM =
Points
Overhang
Floor Area
Type/SC Ornt Len
Hgt Area X SPM
X SOF
= Points
.18 1013.0
42.08
7672.4
Single, Clear E 1.0
5.5' 20.0 59.31
0.96
1141.9
Single, Clear E 5.0
7.7 56.0 59.31
0.65
2164.6
Single, Clear E 1.0
5.5 20.0 59.31
0.96
1143.4
As -Built Total:
96.0
4449.9
WALL TYPES
Area X BSPM
= Points
Type
R-Value Area
X SPM
= Points
Adajcent
309.0 0.7
216.3
Concrete, Int Insul, Exterior
5.0 336.0
1.00
336.0
Exterior
336.0 1.90
638.4
Concrete, Int Insul, Adjacent
5.0 309.0
0.60
185.4
Base Total:
645.0
854.7
As -Built Total:
645.0
521.4
DOOR TYPES
Area X BSPM
= Points
Type
Area
X SPM
= Points
Adjacent
21.0 1.60
33.6
Adjacent Wood
21.0
2.40
50.4
Exterior
0.0 0.00
0.0
Base Total:
21.0
33.6
As -Built Total:
21.0
60.4
CEILING TYPES
Area X BSPM
= Points
Type
R-Value Area
X SPM
= Points
Under Attic
1013.0 0.60
607.8
Under Attic
19.0 1013.0
1.10
1114.3
Base Total:
1013.0
607.8
As -Built Total:
1013.0
1114.3
FLOOR TYPES
Area X BSPM
= Points
Type
R-Value Area
X SPM
= Points
Slab
84.0(p) -31.8
-2671.2
Slab -On -Grade Edge Insulation
0.0 84.0(p)
-31.90
-2679.6
Raised
0.0 0.00
0.0
Base Total:
-2671.2
As -Built Total:
-2679.6
INFILTRATION
Area X BSPM
= Points
Area X SPM
= Points
1013.0 14.31
14496.0
1013.0
14.31
14496.0
Summer Base Points:
20993.3
Summer As -Built Points:
17952.4
Total Summer
X System =
Cooling
Total X Cap X
Duct X System X
Credit
= Cooling
Points
Multiplier
Points
Component Ratio
Multiplier Multiplier
Multiplier
Points
17952.4 1.000
1
0.930 0.341
1.000
5693.3
20993.3
0.3577
7509.3
17962.4 1.00
0.930 0.341
1.000
5693.3
EnergyGaugeTM' DCA Form 60OA-97
FORM 60OA-97
WINTER CALCULATIONS
Residential Whole Building Performance Method A - Details
ADDRESS: , , , PERMIT #:
BASE
AS -BUILT
GLASS TYPES
.1'3 X Conditioned X BWPM =
Points,
Overhang
Floor Area
Type/SC Ornt Len
Hgt Area X WPM X
WOF
= Points
.18 1013.0
4.79
873.3
Single, Clear E 1.0
5.5 20.0 9.96
1.01
201.2
Single, Clear E 5.0
7.7 56.0 9.96
1.09
609.7
Single, Clear E 1.0
5.5 20.0 9.96
1.01
201.2
As -Built Total:
96.0
1012.1
WALL TYPES
Area X
BWPM
= Points
Type
R-Value Area X
WPM
= Points
Adajcent.
309.0
1.8
556.2
Concrete, Int Insul, Exterior
5.0 336.0
2.90
974.4
Exterior
336.0
2.00
672.0
Concrete, Int Insul, Adjacent
5.0 309.0
1.90
587.1
ESase Total:
645.0
1228.2
As -Built Total:
645.0
1561.5
DOOR TYPES
Area X
BWPM
= Points
Type
Area X
WPM
= Points
Adjacent
21.0
4.00
84.0
Adjacent Wood
21.0
5.90
123.9
Exterior
0.0
0.00
0.0
Base Total:
21.0
84.0
As -Built Total:
21.0
123.9
CEILING TYPES Area X
BWPM
= Points
Type
R-Value Area X
WPM
= Points
Under Attic
1013.0
0.60
607.8
Under Attic
19.0 1013.0
1.00
1013.0
Base Total:
1013.0
607.8
As -Built Total:
1013.0
1013.0
FLOOR TYPES
Area X
BWPM
= Points
Type
R-Value Area X
WPM
= Points
Slab
84.0(p)
-1.9
-159.6
Slab -On -Grade Edge Insulation
0.0 84.0(p)
2.50
210.0
Raised
0.0
0.00
0.0
Base Total:
-159.6
As -Built Total:
210.0
INFILTRATION
Area X
BWPM
= Points
Area X
WPM
= Points
1013.0
-0.28
-283.6
1013.0
-0.28
-283.6
Winter Base Points:
2350.1
Winter As -Built Points:
3636.9.
Total Winter X
System
= Heating
Total X Cap X
Duct X System X
Credit =
Heating
Points
Multiplier
Points
Component Ratio
Multiplier Multiplier Multiplier
Points
3636.9 1.000
0.930 1.000
1.000
3382.3
2350.1
1.0730
2521.6
3636.9 1.00
0.930 1.000
1.000
3382.3
EnergyGauge'rm DCA Form 60OA-97
FORM 60OA-97
WATER HEATING & CODE COMPLIANCE STATUS
Residential Whole Building Performance Method A - Details
ADDRESS: , , , PERMIT #:
BASE I AS -BUILT
WATER HEATING
Number of X Multiplier = Total Tank EF Number of X Tank X Multiplier X Credit = Total
Bedrooms Volume Bedrooms Ratio Multiplier
1 2564.00 2564.0 40.0 0.89 1 1.00 2535.19 1.00 2535.2
As -Built Total: 2535.2
CODE
COMPLIANCE
STATUS
BASE
AS -BUILT
Cooling + Heating +
Points Points
Hot Water
Points
= Total
Points
Cooling
Points
+ Heating + Hot Water = Total
Points Points Points
7509.3 2521.6
2564.0
12595.0
6693.3
3382.3 2535.2 11610.8
IF
PASS
�oDWE�
EnergyGaugeTm DCA Form 60OA-97
FORM 60OA-97
Code Compliance Checklist_
Residential Whole Building Pefformance Method A - Details
I ADDRESS: , , , PERMIT #: I
6A-21 INFILTRATION REDUCTION COMPLIANCE CHECKLIST
COMPONENTS
SECTION
REQUIREMENTS FOR EACH PRACTICE
CHECK
Exterior Windows & Doors
606.1.ABC.1.1
Maximum:.3 cfm/s .ft. window area; .5 cfm/s .ft. door area.
Exterior & Adjacent Walls
606.1.ABC.1.2.1
Caulk, gasket, weatherstrip or seal between: windows/doors & frames, surrounding wall;
foundation & wall sole or sill plate; joints between exterior wall panels at corners; utility
penetrations; between wall panels & top/bottom plates; between walls and floor.
EXCEPTION: Frame walls where a continuous infiltration barrier is installed that extends
from and is sealed to the foundation to the top plate.
Floors
606.1.ABC.1.2.2
Penetrations/openings >118" sealed unless backed by truss or joint members.
EXCEPTION: Frame floors where a continuous infiltration barrier is installed that is sealed
to the perimeter, penetrations and seams.
Ceilings
606.1.ABC.1.2.3
Between walls & ceilings; penetrations of ceiling plane of top floor; around shafts, chases,
soffits, chimneys, cabinets sealed to continuous air barrier; gaps in gyp board & top plate;
attic access. EXCEPTION: Frame ceilings where a continuous infiltration barrier is
installed that is sealed at the perimeter, at penetrations and seams.
Recessed Lighting Fixtures
606.1.ABC.1.2.4
Type IC rated with no penetrations, sealed; or Type IC or non -IC rated, installed inside a
sealed box with 1/2" clearance & 3" from insulation; or Type IC rated with < 2.0 cfm from
conditioned space, tested.
Multi -story Houses
606.1.ABC.1.2.5
Air barrier on perimeter of floor cavity between floors.
Additional Infiltration reqts
606.1.ABC.1.3
Exhaust fans vented to outdoors, dampers; combustion space heaters comply with NFPA,
have combustion air.
RA-99 nTI41=P PRPCf_RIPTIVP MIPASI IRFC /mncf ha ma+ nr aar_parlpril by all rpsirlPnr-P_s_1
COMPONENTS
SECTION
REQUIREMENTS
CHECK
Water Heaters
612.1
Comply with efficiency requirements in Table 6-12. Switch or clearly marked circuit
breaker electric or cutoff as must be provided. External or built-in heat trap required.
Swimming Pools & Spas
612.1
Spas & heated pools must have covers (except solar heated). Non-commercial pools
must have a pump timer. Gas spa & pool heaters must have a minimum thermal
efficient of 78%.
Shower heads
612.1
Water flow must be restricted to no more than 2.5 pallons per minute at 80 PSIG.
Air Distribution Systems
610.1
All ducts, fittings, mechanical equipment and plenum chambers shall be mechanically
attached, sealed, insulated, and installed in accordance with the criteria of Section 610.
Ducts in unconditioned attics: R-6 min. insulation.
HVAC Controls
607.1
Separate readily accessible manual or automatic thermostat for each system.
Insulation
604.1, 602.1
Ceilings -Min. R-19. Common walls -Frame R-11 or CBS R-3 both sides.
I
Common ceiling & floors R-11. IF
EnergyGaugeT'" DCA Form 60OA-97 EnergyGauge®/FlaRES'97 FLRCNA-200
c
ENERGY PERFORMANCE LEVEL (EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE SCORE* = 84.3
The higher the score, the more efficient the home.
' '
1. New construction or existing
New
'
12. Cooling systems
2. Single family or multi -family
Multi -family
_ a. Central Unit
Cap: 24.3 kBtu/hr _
& Number of units, if multi -family
1
_
SEER: 10.00 _
4. Number of Bedrooms
1
_ b. N/A
5. Is this a worst case?
Yes
6. Conditioned floor area (ft2)
1013 ft2
c. N/A
_
7. Glass area & type
_
_
a. Clear - single pane
96.0 ft2
_ 13. Heating systems
b. Clear - double pane
0.0 ft2
_ a. Electric Strip
Cap: 17.0 kBtu/hr _
.c. Tint/other SC/SHGC - single pane
0.0 ft2
_
COP: 1.00 _
d. Tint/other SC/SHGC - double pane
0.0 ft2
b. N/A
_
8. Floor types
_
_
- a. Slab -On -Grade Edge Insulation
R=0.0, 84.0(p) ft
_ c. N/A
_
b. N/A
c. N/A
14. Hot water systems
9. Wall types
_ a. Electric Resistance
Cap: 40.0 gallons
a. Concrete, Int Insul, Exterior
R=5.0, 336.0 ft2
_
EF: 0.89 _
b. Concrete, Int Insul, Adjacent
R=5.0, 309.0 ft2
_ b. N/A
_
c. N/A
d. N/A
_ c. Conservation credits
_
e. N/A
(HR-Heat recovery, Solar
10. Ceiling types
_ DIP -Dedicated heat pump)
a. Under Attic
R=19.0, 1013.0 ft2
_ 15. HVAC credits
_
b. N/A
_ (CF-Ceiling fan, CV -Cross ventilation,
c. N/A
BF -Whole house fan,
11. Ducts
_ PT -Programmable Thermostat,
a. Sup: Con. Ret: Con. AH: Interior
Sup. R=4.2, 30.0 ft
_ RB-Attic radiant barrier,
b. N/A
MZ-C-Multizone cooling,
MZ-H-Multizone heating)
I certify that this home has complied with the Florida Energy Efficiency Code For Building
Construction through the above energy saving features which will be installed (or exceeded)
ih this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant features.
Builder Signature:
Address of New Home:
Date:
City/FL Zip:
*NOTE: The home's estimated energy performance score is only available through the FLARES computer program.
This is not a Building Energy Rating. If your score is 80 or greater (or 86 for a US EPADOE EnergyStar''"designation),
your home may qualms for energy efficiency mortgage (EEM incentives if you obtain a Florida Energy Gauge Rating.
Contact the Energy Gauge Hotline at 4071638-1492 or see the Energy Gauge web site at www.fsec. ucf. edu for
information and a list of certified Raters. For information about Florida's Energy Efficiency Code For Building Construction,
contact the Department of Community Affairs at 8501487-1824.
EnergyGauge® (Version: FLRCNA-200)
RIGHT-J CALCULATION PROCEDURES A, B, C, D
0 Entire House
FES, INC. Job:01089 4/21199
34 N.W. 168TH. STREET, NORTH MIAMI BEACH, FL 33169 Phone: 305-653-0212 Fax: 305-653-0232
Procedure A - Winter Infiltration HTM Calculation*
1. Winter infiltration AVF
1.0 ach x 9117 ft3 x 0.0167 = 152 cfm
2. Winter infiltration load
1.1 x 152 cfm x 25 OF Winter TD 4187 Btuh
3. Winter infiltration HTM
4187 Btuh / 117 ft2 Total window = 35.8 Btuh/ft2
and door area
Procedure B - Summer Infiltration HTM Calculation
1. Summer infiltration AVF
0.5 ach x 9117 ft' x 0.0167 = 76 cfm
2. Summer infiltration load
1.1 x 76 cfm x 16 OF Summer TD = 1340 Btuh
3. Summer infiltration HTM
1340 Btuh / 117 ft2 Total window = 11.5 Btuh/ft2
and door area
Procedure C - Latent Infiltration Gain
0.68 x60 gr/lb moist.diff. x 76 cfm = 3094 Btuh
Procedure o - Equipment sizing Loads
1. Sensible sizing load
Sensible ventilation load
1.1 x 100 cfm vent. x 16 OF Summer TD =
1760
Btuh
Sensible load for structure (Line 19) +
13275
Btuh
Sum of ventilation and structure loads =
15035
Btuh
Rating and temperature swing multiplier x
0.96
Equipment sizing load - sensible =
14434
Btuh
2. Latent sizing load
Latent ventilation load
0.68 x 100 cfm vent. x 60 gr/lb moist.diff. _
4064
Btuh
Internal loads = 230 Btuh x 3 people +
690
Btuh
Infiltration load from Procedure C +
3094
Btuh
Equipment sizing load - latent =
7848
Btuh
*Construction Quality is: a No. of Fireplaces is: 0
1
Bold/itallo values have been manually overridden
Printout certified by ACCA to meet all requirements of Manual J 7th Ed.
wrighltsoft Right -Suite Residential^" 5.0.45 RSR23656 2001-Jul-05 11:57:42
/ � HAWrightsoft LOAD CALCS\SAVANNA CLUB\PLAN B1 BOT.rsr Page 1
RIGHT-J LOAD AND EQUIPMENT SUMMARY
Entire House
FES, INC. Job:01089 4/21/99
34 N.W. 168TH. STREET, NORTH MIAMI BEACH, FL 33169 Phone: 305-653-0212 Fax: 305-653-0232
Project• •
For: SAVANNA-CLUB.APT
((PLAN B1 TO.P,_FLJ
Phone: K =e
Notes:
Weather: Fort Lauderdale, FL, US
Winter Design. Conditions
Summer Design Conditions
Outside db 46 OF
Outside db
91
OF
Inside db 71 OF
Inside db
75
OF
Design TD 25 OF
Design TD
16
OF
Daily range
M
Relative humidity
50
%
•
Moisture difference
60
gr/lb
Heating Summary Sensible Cooling Equipment Load Sizing
Building heat loss
11634
Btuh
Structure
13275
Btuh
Ventilation air
0
cfm
Ventilation
1760
Btuh
Ventilation air loss
0
Btuh
Design temperature swing
3.0
OF
Design heat load
11634
Btuh
Use mfg. data
n
Rate/swing multiplier
0.96
Infiltration
Total sens. equip. load
14434
Btuh
Method
Simplified
Latent Cooling Equipment Load Sizing
Construction quality
Average
Fireplaces
0
Internal gains
690
Btuh
Ventilation
4064
Btuh
Heating
Cooling
Infiltration
3094
Btuh
Area (ft')
�1013
1-01-33
Total latent equip. load
7848
Btuh
Volume (ft')
9117
9117
Air changes/hour
1.0
0.5
Total equipment load
22282
Btuh
Equiv. AVF (cfm)
152
76
Heating Equipment
Summary
Cooling Equipment Summary
Make n/a
Make
Trade
Trade
n/a
Efficiency
100.0 EFF
Efficiency
0.0 EER
Heating input
0
Btuh
Sensible cooling
0
Btuh
Heating output
0
Btuh
Latent cooling
0
Btuh
Heating temp rise
0
OF
Total cooling
0
Btuh
Actual heating fan
575
cfm
Actual cooling fan
575
cfm
Heating air flow factor
0.049
cfm/Btuh
Cooling air flow factor
0.043
cfm/Btuh
Space thermostat
Load sensible heat ratio
66
%
Printout certified by ACCA to meet all requirements of Manual J 7th Ed.
wraghtsoft Right -Suite ResidentialT"5.0.45 RSR23656 2001-Jul-05 11:57:42
.4M HAWrightsoft LOAD CALCSISAVANNA CLUBXPLAN B1 BOT.rsr Page 1
RIGHT-J WORKSHEET
Entire House '
FES, INC. , Job:01089 4121199
34 N.W. 168TH. STREET, NORTH MIAMI BEACH, FL 33169 Phone: 305-653-0212 Fax: 305-653-0232
NWIVUAL J: /m to.
1
Name of room
Entire House
PLAN 131
2
Length of exposed wall
84.0 ft
84.0 ft
3
Room dimensions
10.0 x 101.3 ft
4
Ceiings Condit. Option
9.0 ftl d
9.0 ft heattcool
TYPE OF
CS
HTM
Area
Load (Btuh)
Area
Load (Btuh)
Area
Area
EXPOSURE
NO.
Htg Clg
(ft�
Htg Clg
(ft�
Htg I Clg
Htg Clg
Htg Clg
5
Gross
a 14B
3.6
1.8
432
-
'•*`
432
'*•'
-
•"•
'•••
'*•'
*•*•
Exposed
b 12C
2.3
1.8
0
-
"•'
0
-
••'•
•'**
•`**
*•■•
••**
walls and
c 13N
1.4
0.6
330
""
•"'
330
•'•'
-
' '*
`•"
••••
•••'
partitions
d 13C
0.9
1.0
0
"*'
'•`•
0
`•`•
••'•
••*•
•'••
••**
***•
6
Windows and
a 1B
26.1
"
96
2508
"'•'
96
2508
"'*
••••
'**'
glass doors
b 813
26.1
'*
0
0
•'•"
0
0
"*•'
•*•'
•*"
Heating
c
0.0
"
0
0
-
0
0
""
`**■
•*`*
d
0.0
"
0
0-
0
0
•'"'
""
`""
e
0.0
*'
0
0-
0
0
*"'
**••
*"•
7
Windows and
North
27.8
26
`•*
735
26
`•'*
735
""
••"
glass doors
NE/NW
0.0
0
""•
0
0
"•'
0
•"'
'*`*
Cooling
E/W
85.8
70
'•'•
5968
70
""
5968
SE/SW
0.0
0
""
0
0
""
0
`•'*
'*•'
South
0.0
0
"*`
0
0
'•*'
0
`*'*
•••'
Harz
0.0
0
'•'•
0
0
"•'
0
8
Other doors
a 10D
11.5
9.0
21
242
189
21
242
189
b 10A
14.0
11.0
0
0
0
0
0
0
c
0.0
0.0
0
0
0
0
0
0
9
Net
a 14B
3.6
1.8
336
1210
595
336
1210
595
exposed
b 12C
2.3
1.8
0
0
0
0
0
0
walls and
c 13N
1.4
0.6
309
445
200
309
445
200
partitions
d 13C
0.9
1.0
0
0
0
0
0
0
e
0.0
0.0
0
0
0
0
0
0
f
0.0
0.0
0
0
0
0
0
0
10
Ceilings.
a 16D
1.3
2.1
1013
1342
2148
1013
1342
2148
b
0.0
0.0
0
0
0
0
0
0
c
0.0
0.0
0
0
0
0
0
0
d
0.0
0.0
0
0
0
0
0
0
e
0.0
0.0
0
0
0
0
0
0
f
0.0
0.0
0
0
0
0
0
0
11
Floors
a 22A
20.3
0.0
84
1701
0
84
1701
0
(Note: room
b 91A
4.8
2.2
0
0
0
0
0
0
perimeter
c
0.0
0.0
0
0
0
0
0
0
is displ.
d
0.0
0.0
0
0
0
0
0
0
for slab
a
0.0
0.0
0
0
0
0
0
0
floors)
f
0.0
0.0
0
0
0
0
0
0
12
Infiltration a 1
35.81
11.5
117
4187
1340
1171
4187
1340
13
Subtotal loss=6+8..+11+12
*•*'
11634
•"`*
"•*`
11634
"'•
""
`•:'
■•■*
*•**
Less external heating
•'•'
0
`•"
"**'
0
""
*••*
'**'
`••■
`••*
Less transfer
-
0
*■**
•**•
0
•**•
••■■
••**
..**
****
14
Duct loss
0%
0
"*'
0°/
0
•"`
°/
•"•
°/
'•*•
15
Total loss =13+14
'*"
11634
"'•
`•**
11634
""
'""
••'•
•"'
•*•*
16
Int gains: People @ 300
3
"••
900
3
"'•'
900
"•'
*••'
Appl. @ 1200
1
'*"
1200
1
•••'
1200
"••*
17
Subtot RSH gain=7+8..+12+16
•'•'
"••
13275
••"
-
13275
•"'
"`•"
••"•
"'"'
Less external cooling
'*"
•••*
0
•**'
***•
0
•***
**•*
*••*
****
Less transfer
****
*'*'
0
■*•*
****
0
+•**
****
***■
•■■•
18
Duct gain
0%
***•
0
0°/
****
0
°/
**+*
°/
....
19
Total RSH gain=(17+18)*PLF
1.00
13275
1.00
••"
13275
'•"
•*"
20
Air required (cfm)
`***
575
575
•'•"
575
575
•"`
`•••
Printout certified by ACCA to meet all requirements of Manual J 7th Ed.
wraghtsoFC Right -Suite Residentialn" 5.0.45 RSR23656 2001-Jul-05 11:57:42
C5CA H:\Wrightsoft LOAD CALLS\SAVANNA CLUBIPLAN B1 BOT.rsr Page 1
A
0
FORM 60OA-97
FLORIDA ENERGY EFFICIENCY CODE
FOR BUILDING CONSTRUCTION
Florida Department of Community Affairs
Residential Whole Building Performance Method A
Project Name: SAVANNA CLUB'PLANi!32TtOP Builder:
Address: Permitting Office: PORT ST-40C
City, State: PORT ST LUCIE, FL Permit Number:
Owner: RICH PROPERTIES Jurisdiction Number: 66 /200
Climate Zone: Central
1. New construction or existing
New _
12. Cooling systems
2. Single family or multi -family
Multi -family _
a. Central Unit
3� Number of units, if multi -family
1
4. Number of Bedrooms
1 _
b. N/A
5. Is this a worst case?
Yes
6. Conditioned floor area (ft2)
_
10$ 2' '
c. N/A
7. Glass area & type
_
a. Clear - single pane
67.0 ft2 _
13. Heating systems
b. Clear - double pane
0.0 ft2 _
a. Electric Strip
•c. Tintlother SC/SHGC - single pane
0.0 ft2 _
d. Tintlother SC/SHGC - double pane
0.0 ft2
b. N/A
8. Floor types
a. Slab -On -Grade Edge Insulation
R=0.0, 78.0(p) ft _
c. N/A
b. N/A
c. N/A
14. Hot water systems
9. Wall types
_
a. Electric Resistance
a. Frame, Wood, Exterior
R=3.0, 110.0 ft2 _
b. Concrete, Int Insul, Adjacent
R=3.0, 309.0 ft2 _
b. N/A
c. N/A
_
d. N/A
_
c. Conservation credits
e. N/A
(HR-Heat recovery, Solar
10. Ceiling types
_
DHP-Dedicated heat pump)
a. Under Attic
R=19.0, 1084.0 ft2 _
15. HVAC credits
b. N/A
_
(CF-Ceiling fan, CV -Cross ventilation,
c. N/A
HF-Whole house fan,
11. Ducts
_
PT -Programmable Thermostat,
a. Sup: Con. Ret: Con. AH: Interior
Sup. R=4.2, 40.0 ft _
RB-Attic radiant barrier,
b. N/A
MZ-C-Multizone cooling,
MZ-H-Multizone heating)
Glass/Floor Area: 0.06 Total as -built points: 11322.00 Y PASS
Total base points: 12698.00
I hereby certify that the plans and specifications covered
by this calculation are in compliance with the Florida
Energy Code.
PREPARED BY:Alifrl 510� -_ SJ T,vc
DATE: L 5yof
I hereby certify that this building, as designed, is in
compliance with the Florida Ener o
OWNER/AGENT:
DATE:
Cap: 26.0 kBtu/hr
SEER: 10.00
Cap: 17.0 kBtu/hr
COP: 1.00
Cap: 40.0 gallons _
EF: 0.89
Review of the plans and
ST,9?�
specifications covered by this
indicates
o�z�
ti
calculation compliance
with the Florida Energy Code.
d
Before construction is completed
0 �
a
this building will be inspected for
compliance with Section 553.908'coD
Florida Statutes.
wg���
BUILDING OFFICIAL:
DATE:
EnergyGauge® (Version: FLRCNA-200)
S
k
FORM 60OA-97
FLORIDA ENERGY EFFICIENCY CODE
FOR BUILDING CONSTRUCTION
Florida Department of Community Affairs
Residential Whole Building Performance Method A
Project Name: SAVANNA CLUB PLAN 62 O-P Builder:
Address: Permitting Office:
City, State: PORT ST LUCIE, FL Permit Number:
Owner: RICH PROPERTIES Jurisdiction Number:
Climate Zone: Central
1. New construction or existing
New _
12. Cooling systems
2. Single family or multi -family
Multi -family _
a. Central Unit
Cap: 26.0 kBtu/hr _
3. Number of units, if multi -family
1 _
SEER: 10.00
4. Number of Bedrooms
1 _
b. N/A
_
5. Is this a worst case?
Yes
6. Conditioned floor area (ft2)
1084 ft? `
c. N/A
_
7. Glass area & type
_
_
a. Clear - single pane
67.0 ft2 _
13. Heating systems
b. Clear - double pane
0.0 ft2 _
a. Electric Strip
Cap: 17.0 kBtu/hr _
`c. Tint/other SC/SHGC - single pane
0.0 ft2 _
COP: 1.00
d. Tint/other SC/SHGC - double pane
0.0 ft2
b. N/A
_
8. Floor types
_
_
' a. Slab -On -Grade Edge Insulation
R=0.0, 78.0(p) ft _
c. N/A
_
b. N/A
c. N/A
14. Hot water systems
9. Wall types
_
a. Electric Resistance
Cap: 40.0 gallons _
a. Frame, Wood, Exterior
R=3.0, 110.0 ft2 _
EF: 0.89 _
b. Concrete, Int Insul, Adjacent
R=3.0, 309.0 ft2 _
b. N/A
c. N/A
d. N/A
_
c. Conservation credits
_
e. N/A
(HR-Heat recovery, Solar
10. Ceiling types
_
DHP-Dedicated heat pump)
a. Under Attic
R=19.0, 1084.0 ft2 _
15. HVAC credits
b. N/A
_
(CF-Ceiling fan, CV -Cross ventilation,
c. N/A
HF-Whole house fan,
11. Ducts
_
PT -Programmable Thermostat,
a. Sup: Con. Ret: Con. AH: Interior
Sup. R=4.2, 40.0 ft _
RB-Attic radiant barrier,
b. N/A
MZ-C-Multizone cooling,
MZ-H-Multizone heating)
Glass/Floor Area: 0.06 Total as -built points: 11322.00 Y PASS
Total base points: 12698.00
1-hereby certify that the plans and specifications covered
by this calculation are in compliance with the Florida
Energy Code.
PREPARED BY:A/&rl Sllid s-�S , Ttic,
DATE:
hereby certify that this building, ip_
ned,is in
compliance with the Florida En.
OWNER/AGENT:
DATE: d i
Review of the plans and
,'THEs"
specifications covered by this
indicates compliance
do
calculation
with the Florida Energy Code.
Before construction is completed
this building will be inspected for
compliance with Section 553.908
11•o0D
Florida Statutes.
WE`D
BUILDING OFFICIAL:
DATE:
EnergyGauge® (Version: FLRCNA-200)
FORM 60OA-97
SUMMER CALCULATIONS
e
Residential Whole Building Performance Method A - Details
ADDRESS: , PORT ST LUCIE, FL, PERMIT #:
BASE
AS -BUILT
GLASS TYPES
.18 X Conditioned X BSPM =
Points
Overhang
Floor Area
Type/SC Ornt Len
Hgt Area X SPM
X SOF
= Points
18 1084.0 42.08
8210.2
Single, Clear E 1.0
5.5 '20.0 59.31
0.96
1141.9
Single, Clear E 1.0
5.5 27.0 59.31
0.96
1543.6
Single, Clear E 1.0
5.5 20.0 59.31
0.96
1143.4
As -Built Total:
67.0
3828.8
WALL TYPES
Area X BSPM
= Points
Type
R-Value Area
X SPM
= Points
Adajcent
309.0 0.7
216.3
Frame, Wood, Exterior
3.0 110.0
4.64
510.7
Exterior
110.0 1.90
209.0
Concrete, Int Insul, Adjacent
3.0 309.0
0.70
216.3
Base Total:
419.0
425.3
As -Built Total:
419.0
727.0
DOOR TYPES
Area X BSPM
= Points
Type
Area
X SPM
= Points
Adjacent
21.0 1.60
33.6
Adjacent Wood
21.0
2.40
50.4
Exterior
0.0 0.00
0.0
Base Total:
21.0
33.6
As -Built Total:
21.0
50.4
CEILING TYPES Area X BSPM
= Points
Type
R-Value Area
X SPM
= Points
Under Attic
1084.0 0.60
650.4
Under Attic
19.0 1084.0
1.10
1192.4
Base Total:
1084.0
650.4
As -Built Total:
1084.0
1192.4
FLOOR TYPES
Area X BSPM
= Points
Type
R-Value Area
X SPM
= Points
Slab
78.0(p) -31.8
-2480.4
Slab -On -Grade Edge Insulation
0.0 78.0(p)
-31.90
-2488.2
Raised
0.0 0.00
0.0
Base Total:
-2480.4
As -Built Total:
-2488.2
INFILTRATION
Area X BSPM
= Points
Area X SPM
= Points
1084.0 14.31
15512.0
1084.0
14.31
15512.0
a
Summer Base Points:
22351.1
Summer As -Built Points:
18822.6
Total Summer
X System =
Cooling
Total X Cap X
Duct X System X
Credit
= Cooling
Points
Multiplier
Points
Component Ratio
Multiplier Multiplier
Multiplier
Points
18822.5 1.000
1
0.930 0.341
1.000
5969.2
22351.1
0.3577
7995.0
18822.6 1.00
0.930 0.341
1.000
5969.2
EnergyGaugeTm DCA Form 60OA-97
FORM 60OA-97
WINTER G kCULATIONS
Residential Whole Building Performance Method A - Details
ADDRESS: , PORT ST LUCIE, FL, PERMIT #:
BASE
AS -BUILT
GLASS TYPES
.18 X Conditioned X BWPM =
Points.
Overhang
Floor Area
Type/SC Ornt Len
Hgt Area X WPM X WOF
= Points
18 1084.0
4.79
934.5
Single, Clear E 1.0
5.5 20.0 9.96
1.01
201.2
Single, Clear E 1.0
5.5 27.0 9.96
1.01
271.6
Single, Clear E 1.0
5.5 20.0 9.96
1.01
201.2
As -Built Total:
67.0
674.0
WALL TYPES
Area X
BWPM
= Points
Type
R-Value Area X
WPM
= Points
Adajcent
309.0
1.8
556.2
Frame, Wood, Exterior
3.0 110.0
4.96
545.3
Exterior
110.0
2.00
220.0
Concrete, Int Insul, Adjacent
3.0 309.0
2.30
710.7
Base Total:
419.0
776.2
As -Built Total:
419.0
1256.0
DOOR TYPES
Area X
BWPM
= Points
Type
Area X
WPM
= Points
Adjacent
21.0
4.00
84.0
Adjacent Wood
21.0
5.90
123.9
Exterior
0.0
0.00
0.0
Base Total:
21.0
84.0
As -Built Total:
21.0
123.9
CEILING TYPES Area X
BWPM
= Points
Type
R-Value Area X
WPM
= Points
Under Attic
1084.0
0.60
650.4
Under Attic
19.0 1084.0
1.00
1084.0
Base Total:
1084.0
650.4
As -Built Total:
1084.0
1084.0
FLOOR TYPES
Area X
BWPM
= Points
Type
R-Value Area X
WPM
= Points
Slab
78.0(p)
-1.9
-148.2
Slab -On -Grade Edge Insulation
0.0 78.0(p)
2.50
195.0
Raised
0.0
0.00
0.0
Base Total:
-148.2
As -Built Total:
195.0
INFILTRATION
Area X
BWPM
= Points
Area X
WPM
= Points
1084.0
-0.28
-303.5
1084.0
-0.28
-303.5
Winter Base Points:
1993.4
Winter As -Built Points:
3029.4
Total Winter X
System
= Heating
Total X Cap X
Duct X System X
Credit
= Heating
Points
Multiplier
Points
Component Ratio
Multiplier Multiplier Multiplier
Points
3029.4 1.000
0.930 1.000
1.000
2817.3
1993.4
1.0730
2138.9
3029.4 1.00
0.930 1.000
1.000
2817.3
EnergyGaugeTm DCA Form 60OA-97
FORM 60OA-97
WATER HEATING & CODE COMPLIANCE STATUS
Residential Whole Building Performance Method A - Details
ADDRESS: , PORT ST LUCIE, FL, PERMIT #:
BASE AS -BUILT
WATER HEATING
Number of X Multiplier = Total . Tank EF Number of X Tank X Multiplier X Credit = Total
Bedrooms Volume Bedrooms Ratio Multiplier
1 2564.00 - 2564.0 40.0 0.89 1 1.00 2535.19 1.00 2535.2
As -Built Total: 2535.2
CODE
COMPLIANCE
STATUS
BASE
AS -BUILT
Cooling + Heating +
Points Points
Hot Water
Points
= Total
Points
Cooling
Points
+ Heating + Hot Water = Total
Points Points Points
7996.0 2138.9
2564.0
12697.9
5969.2
2817.3 2536.2 11321.7
PASS
EnergyGauge'rm DCA Form 60OA-97
FORM 60OA-97
Code Compliance Checklist
Residential Whole Building Performance Method A - Details
ADDRESS: , PORT ST LUCIE, FL, PERMIT #:
6A-21 INFILTRATION REDUCTION COMPLIANCE CHECKLIST
COMPONENTS
SECTION
REQUIREMENTS FOR EACH PRACTICE
CHECK
Exterior Windows & Doors
606.1.ABC.1.1
Maximum:.3 cfm/s .ft. window area; .5 cfm/s .ft. door area.
Exterior & Adjacent Walls
606.1.ABC.1.2.1
Caulk, gasket, weatherstrip or seal between: windows/doors & frames, surrounding wall;
foundation & wall sole or sill plate; joints between exterior wall panels at comers; utility
penetrations; between wall panels & top/bottom plates; between walls and floor.
EXCEPTION: Frame walls where a continuous infiltration barrier is installed that extends
from and is sealed to the foundation to the top plate.
Floors
606.1.ABC.1.2.2
Penetrations/openings >1/8" sealed unless backed. by truss or joint members.
EXCEPTION: Frame floors where a continuous infiltration barrier is installed that is sealed
to the perimeter, penetrations and seams.
Ceilings
606.1.ABC.1.2.3
Between walls &.ceilings; penetrations of ceiling plane of top floor; around shafts, chases,
soffits, chimneys, cabinets sealed to continuous air barrier; gaps in gyp board & top plate;
attic access. EXCEPTION: Frame ceilings where a continuous infiltration barrier is
installed that is sealed at the perimeter, at penetrations and seams.
Recessed Lighting Fixtures
606.1.ABC.1.2.4
Type IC rated with no penetrations, sealed; or Type IC or non -IC rated, installed inside a
sealed box with 1/2" clearance & 3" from insulation; or Type IC rated with < 2.0 cfm from
conditioned space, tested.
Multi -story Houses
606.1.ABC.1.2.5
Air barrier on perimeter of floor cavity between floors.
Additional Infiltration reqts
606.1.ABC.1.3
Exhaust fans vented to outdoors, dampers; combustion space heaters comply with NFPA,
have combustion air.
FA-99 nT1411=R PRFCf_RIPTIVF MPASI IPPA /mnef ha ma+ nr axcparlprl by all rpc11rlPncps_1
COMPONENTS
SECTION
REQUIREMENTS
CHECK
Water Heaters
612.1
Comply with efficiency requirements in Table 6-12. Switch or clearly marked circuit
breaker electric or cutoff as must be provided. External or built-in heat trap required.
Swimming Pools & Spas
612.1
Spas & heated pools must have covers (except solar heated). Non-commercial pools
must have a pump timer. Gas spa & pool heaters must have a minimum thermal
efficiency of 78%.
Shower heads
612.1
Water flow must be restricted to no more than 2.5 gallons per minute at 80 PSIG.
Air Distribution Systems
610.1
All ducts, fittings, mechanical equipment and plenum chambers shall be mechanically
attached, sealed, insulated, and installed in accordance with the criteria of Section 610.
Ducts in unconditioned attics: R-6 min. insulation.
HVAC Controls
607.1
Separate readily accessible manual or automatic thermostat for each system.
Insulation
604.1, 602.1
Ceilings -Min. R-19. Common walls -Frame R-11 or CBS R-3 both sides.
Common ceiling & floors R-11.
EnergyGaugeTm DCA Form 60OA-97 EnergyGauge®/FlaRES'97 FLRCNA-200
J 11
ENERGY PERFORMANCE LEVEL (EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE SCORE* = 85.2
The higher the score, the more efficient the home.
RICH PROPERTIES,, PORT ST LUCIE, FL,
1. New construction or existing
New _
12. Cooling systems
2. Single family or multi -family
Multi -family _
a. Central Unit
Cap: 26.0 kBtu/hr _
3. Number of units, if multi -family
1 _
SEER: 10.00
4. Number of Bedrooms
1 _
b. N/A
_
5. Is this a worst case?
Yes
6. Conditioned floor area (ft2)
108 _ft2
c. N/A
7. Glass area & type
a. Clear - single pane
67.0 ft2 _
13. Heating systems
b. Clear - double pane
0.0 ft2 _
a. Electric Strip
Cap: 17.0 kBtu/hr
' c. Tint/other SC/SHGC - single pane
0.0 ft2 _
COP: 1.00 _
d. Tint/other SC/SHGC - double pane
0.0 ft2
b. N/A
_
8. Floor types
_
_
a. Slab -On -Grade Edge Insulation
R=0.0, 78.0(p) ft _
c. N/A
_
b. N/A
c. N/A
14. Hot water systems
9. Wall types
_
a. Electric Resistance
Cap: 40.0 gallons
a. Frame, Wood, Exterior
R=3.0, 110.0 ft2 _
EF: 0.89
b. Concrete, hit Insul, Adjacent
R=3.0, 309.0 ft2 _
b. N/A
_
c. N/A
d. N/A
_
c. Conservation credits
_
e. N/A
(HR-Heat recovery, Solar
10. Ceiling types
_
DHP-Dedicated heat pump)
a. Under Attic
R=19.0, 1084.0 ft2 _
15. HVAC credits
_
b. N/A
_
(CF-Ceiling fan, CV -Cross ventilation,
c. N/A
HF-Whole house fan,
11. Ducts
_
PT -Programmable Thermostat,
a. Sup: Con. Ret: Con. AH: Interior
Sup. R=4.2, 40.0 ft _
RB-Attic radiant barrier,
b. N/A
MZ-C-Multizone cooling,
MZ-H-Multizone heating)
I certify that this home has complied with the Florida Energy Efficiency Code For Building c
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant features.
Builder Signature: Date:
Address of New Home:
City/FL Zip:
*NOTE: The home's estimated energy performance score is only available through the FLARES computer program.
This is not a Building Energy Rating. If your score is 80 or greater (or 86 for a US EPADOE EnergyStar'mdesignation),
your home may qualify for energy efficiency mortgage (EEM incentives ifyou obtain a Florida Energy Gauge Rating.
Contact the Energy Gauge Hotline at 4071638-1492 or see the Energy Gauge web site at www.fsec. ucf. edu for
information and a list of certified Raters. For information about Florida's Energy Efficiency Code For Building Construction,
contact the Department of Community Affairs at 8501487-1824.
EnergyGauge® (Version: FLRCNA-200)
RIGHT-J LOAD AND EQUIPMENT SUMMARY
Entire House
FES, INC. Job: 01089 4121199
34 N.W. 166TH. STREET, NORTH MIAMI BEACH, FL 33169 Phone: 305-653-0212 Fax: 305-653-0232
Project• •
For: SAVANNA CLUB APT
PLAN-132-TOP; FL3
Phone: WG e
Notes:
Design Information
Weather: Fort Lauderdale, FL, US
Winter Design Conditions Summer Design Conditions
Outside db 46 OF Outside db 91 OF
Inside db 71 OF Inside db 75 OF
Design TD 25 OF Design TD 16 OF
Daily range M
Relative humidity 50 %
Moisture difference 60 gr/lb
Heating Summary Sensible Cooling Equipment Load Sizing
Building heat loss
10920
Btuh
Structure
12528
Btuh
Ventilation air
0
cfm
Ventilation
1760
Btuh
Ventilation air loss
0
Btuh
Design temperature swing
3.0
OF
Design heat load
10920
Btuh
Use mfg. data
n
Rate/swing multiplier
0.96
Infiltration
Total sens. equip. load
13716
Btuh
Method
Simplified
Latent Cooling Equipment Load
Sizing
Construction quality
Average
Fireplaces
0
Internal gains
690
Btuh
Ventilation
4064
Btuh
Heating
Cooling
Infiltration
3311
Btuh
Area (ft2)
�10-4
1084
Total latent equip. load
8065
Btuh
Volume (ft3)
9756
9756
Air changes/hour
1.0
0.5
Total equipment load
21781
Btuh
Equiv. AVF (cfm)
163
81
Heating Equipment Summary
Cooling Equipment Summary
Make n/a
Make
Trade
Trade
n/a
Efficiency
100.0 EFF
Efficiency
0.0 EER
Heating input
0
Btuh
Sensible cooling
0
Btuh
Heating output
0
Btuh
Latent cooling
0
Btuh
Heating temp rise
0
OF
Total cooling
0
Btuh
Actual heating fan
542
cfm
Actual cooling fan
542
cfm
Heating air flow factor
0.050
cfm/Btuh
Cooling air flow factor
0.043
cfm/Btuh
Space thermostat
Load sensible heat ratio
64
%
Printout certified by ACCA to meet all requirements of Manual J 7th Ed.
.jQ_t� wrjghtsoft Right -Suite ResidentialT 5.0.45 RSR23656 2001-Jul-05 12:05:01
ACCk H:1Wrightsoft LOAD CALCSISAVANNA CLUBTLAN B2 TOP.rsr Page 1
oil
:3
0
C
0
CD
CD
n
D_
O
3
CD
3
CD
a
co
0
�-q
9
O f0 W V D7
w A W
N
O
co
co
V
0)
N
m
X
A W N>
DO NNC .�-.
OC�NtDC
O NNZ
rD
rD
c,^
CD
I5T�1
CDO G7
Era,. 0 rG
�.iNN�
0�'N3NM. O
7
_
`z.�'NO
cz
CD
ON
.01n
NN
C. Vl O.
._7.,N ,DO
..NO,
��
O m
j0f0 3�
3� m
a ro a m° d
C rD y
CD
a°, a�i cl
" 60,
A 0. t�
Q•
H
V)
>> 1D
CL
a
o
o
o
ro o f
o 1D N N
» o
n
cn p
�
rn p z
0
rD = N (O
N y NCD p
7
O
N n
00
O
O y
y n
C T
C
3
n O D)
11 N 0
3
tD
N n
n
m
ID
3
22
W 11
y'D
0
Cf�f
=II O 3•
+ N W
\
N
rn
^CD n0 Cd
�tD n0QN
�fD O.O QN
O O'N
[iI
m2Zo
�'W dO CT 0)
-'�N n0 QtD
° 11 D('pD
A �:•�
G
Cj N
»
OD -+
ZCi
CO ma O
ro
N
O o
O
D�
O
0Znm
co
asczZ
W�
nZn�
Ow
o —
CD
N
n
O
O 000 A O
00 000 —
O 00> N W
O A-+
000000)
00 O> N W
f0
'O
CO
0000 W W
C0000 W
G OrOA W 0
60 C",
OOGO»
00 (D.P. W 0)
=
0
O
O
OO 00
O»>
CCDn O
�=00>O»O
CD
00
COOOOONO
00000>
OOG CD coDD
000
OOOdD00
0000I OD co
»O
O
r
00
07
V
W
Cl)
O
N
T
D)
W W A
N
O 7
os >W
o
co
00 V CT
y1 N
�r}
60
CD co0AD
W
A A
A
N
m
O.
coC
O CD
A
N
0000 O
O
m
000000
00000 0
A
000 CT CO O
00 N
00 0000
W
v
N N
i i i
N
OCD 0)
>
A
i
S
O.
AN N 00
N co CD 00 aD 00
W
A
000000
CNO
00000 W
OOOOAA
OD
OOCO
000 0000
!
i
D
_ v
O
0 O s
00
>W
0
Co
co
V
p p 00 OCD
poppp
pppOOA
OOOt0 O01
00
O00 V pp
O pppOV
W W A
0000 V 01
.=0 Z
x 113
}S
i S S
*S
6DOj
Ot • • • » • »
O O
co CD
A
A
r71
A
A N V
A
N
A
i s a
V
#;
n
`'pWN
OD 0
A
N
N N
O O O O O
tb
O
co
O O O O O O
W
0 0 0 0 0 0)
A A
O O O CT W O
O O N
cn
O O O O O O
W
O_ A
Er
x
N N>
AN N 00
i S
(A(,��
N
coN
ca
OCO0)
CD
CT
A
i i i
S
N ODOOOp 00
A
000000
00000 fD
OOOOAA
Coco
OOOCa 00
a7
x i
i i i i
i y i
CO
d
35
liSi2
ro
n,;a
N
Z
n
N�
2O
'AA '^
V/
m
m
I
I
RIGHT-J CALCULATION PROCEDURES A, B, C, D
Entire House
0 FES, INC. Job: 01089 4121199
34 N.W. 168TH. STREET, NORTH MIAMI BEACH, FL 33169 Phone: 305-653-0212 Fax: 305-653-0232
Procedure A - Winter Infiltration HTM Calculation*
1. Winter infiltration AVF
1.0 ach x 9756 ft3 x 0.0167 = 163 cfm
2. Winter infiltration load
1.1 x 163 cfm x 25 OF Winter TD = 4480 Btuh
3. Winter infiltration HTM
4480 Btuh / 88 ft2 Total window = 50.9 Btuh/ft2
and door area
Procedure B - Summer Infiltration HTM Calculation
1. Summer infiltration AVF
0.5 ach x 9756 ft3 x 0.0167 = 81 cfm
2. Summer infiltration load
1.1 x 81 cfm x 16 OF Summer TD = 1434 Btuh
3. Summer infiltration HTM
1434 Btuh / 88 ft2 Total window = 16.3 Btuh/ft2
and door area
Procedure C - Latent Infiltration Gain
0.68 x 60 gr/lb moist.diff. x 81 cfm = 3311 Btuh
-roceclure U - Equipment sizing Loacis
1. Sensible sizing load
Sensible ventilation load
1.1 x 100 cfm vent. x 16
Sensible load for structure (Line 19)
Sum of ventilation and structure loads
Rating and temperature swing multiplier
Equipment sizing load - sensible
2. Latent sizing load
Latent ventilation load
OF Summer TD =
x
0.68 x 100 cfm vent. x 60 gr/lb moist.diff
Internal loads = 230 Btuh x 3 people
Infiltration load from Procedure C
Equipment sizing load - latent
`Construction Quality is: a
+Y
1760 Btuh
12528 Btuh
14288 Btuh
0.96
13716 Btuh
4064 Btuh
690 Btuh
3311 Btuh
8065 Btuh
No. of Fireplaces is: 0
BoWitalic values have been manually overridden
Printout certified by ACCA to meet all requirements of Manual J 7th Ed.
S wrightsoft Right -Suite Residential"" 5.0.45 RSR23656 2001-Jul-05 12:05:01
M. H:%Wrightsoft LOAD CALCS\SAVANNA CLUBIPLAN B2 TOP.rsr Page 1
I
FORM 600A-97
FLORIDA ENERGY EFFICIENCY CODE
FOR BUILDING CONSTRUCTION
Florida Department of Community Affairs
Residential Whole Building Performance Method A
Project Name: SAVANNA CLUB PLAN A1-13OTTOM Builder:
Address: Permitting Office: p09T %7- AociE
City, State: PORT ST LUCIE, FL Permit Number:
Owner: RICH PROPERTIES Jurisdiction Number: 66/A00
Climate Zone: Central
1.
New construction or existing
New _
12. Cooling systems
2.
Single family or multi -family
Multi -family _
a. Central Unit
S.
Number of units, if multi -family
1
4.
Number of Bedrooms
1 _
b. N/A
5.
Is this a worst case?
Yes _
6.
Conditioned floor area (ft2)
814`ftz
c. N/A
7.
Glass area & type
a. Clear - single pane
54.0 ft2 _
13. Heating systems
b. Clear - double pane
0.0 ft2 _
a. Electric Strip
c. Tintlother SC/SHGC - single pane
0.0 ft2 _
d. Tint/other SC/SHGC - double pane
0.0 ft2
b. N/A
$.
Floor types
a. Slab -On -Grade Edge Insulation
R=0.0, 98.0(p) ft _
c. N/A
b. N/A
_
c. N/A
14. Hot water systems
9.
Wall types
_
a. Electric Resistance
a. Concrete, Int Insul, Exterior
R=3.0, 450.0 ft2 _
b. Concrete, Int Insul, Adjacent
R=3.0, 304.5 ft2 _
b. N/A
c. N/A
_
d. N/A
_
c. Conservation credits
e. N/A
(HR-Heat recovery, Solar
10. Ceiling types
_
DHP-Dedicated heat pump)
a. N/A
_
15. HVAC credits
b. N/A
_
(CF-Ceiling fan, CV -Cross ventilation,
c. N/A
HF-Whole house fan,
11. Ducts
_
PT -Programmable Thermostat,
a. Sup: Con. Ret: Con. AH: Interior
Sup. R=4.2, 30.0 ft _
RB-Attic radiant barrier,
b. N/A
MZ-C-Multizone cooling,
MZ-H-Multizone heating)
Glass/Floor Area: 0.06 Total as -built points: 9667.60 r PASS
Total base points: 10844.00
r hereby certify that the plans and specifications covered
by this calculation are in compliance with the Florida
Energy Code.
PREPARED BY: A/lbef-O' 54d6 9'65 -X"ac
DATE: a!
I hereby certify that this building, as-desig7i d, is in
compliance with the Florida Energy •
OWNER/AGENT: zildffle
DATE:
EnergyGaugeO (Version: FLRCNA-200)
Cap: 21.5 kBtu/hr
SEER:10.00 _
Cap: 17.0 kBtu/hr _
COP: 1.00 _
Cap: 30.0 gallons
EF: 0.89
Review of the plans and
ztE sT
specifications covered by this
yo4
calculation indicates compliance
with the Florida Energy Code.
Before construction is completed
y
this building will be.inspected for
compliance with Section 553.908
�•0on�
Florida Statutes.
BUILDING OFFICIAL:
DATE:
C
FORM 60OA-97
FLORIDA ENERGY EFFICIENCY CODE
FOR BUILDING CONSTRUCTION
Florida Department of Community Affairs
Residential Whole Building Performance Method A
Project Name: SAVANNA CLUB PLAN;A'hBOTTOM Builder:
Address: Permitting Office:
City, State: PORT ST LUCIE, FL Permit Number:
Owner: RICH -PROPERTIES Jurisdiction Number:
Climate Zone: Central
1. New construction or existing
New _
12. Cooling systems
2. Single family or multi -family
Multi -family _
a. Central Unit
3. Number of units, if multi -family
1 _
4. Number of Bedrooms
1 _
b. N/A
5. Is this a worst case?
Yes
6. Conditioned floor area (ft2)
89 1
c. N/A
7. Glass area & type
_
a. Clear - single pane
54.0 ft2. _
13. Heating systems
b. Clear - double pane
0.0 ft2 _
a. Electric Strip
c. Tint/other SC/SHGC - single pane
0.0 ft2 _
d. Tint/other SC/SHGC - double pane
0.0 ft2
b. N/A
S. Floor types
a. Slab -On -Grade Edge Insulation
R=0.0, 98.0(p) ft _
c. N/A
b. N/A
c. N/A
14. Hot water systems
9. Wall types
_
a. Electric Resistance
a. Concrete, Int. Insul, Exterior
R=3.0, 450.0 ft2 _
b. Concrete, Int Insul, Adjacent
R=3.0, 304.5 ft2 _
b. N/A
c. N/A
d. N/A
_
c. Conservation credits
e. N/A
(HR-Heat recovery, Solar
10. Ceiling types
_
DHP-Dedicated heat pump)
a. N/A
_
15. HVAC credits
b. N/A
_
(CF-Ceiling fan, CV -Cross ventilation,
c. N/A
BF -Whole house fan,
11. Ducts
_
PT -Programmable Thermostat,
a. Sup: Con. Ret: Con. AH: Interior
Sup. R=4.2, 30.0 ft _
RB-Attic radiant barrier,
b. N/A
MZ-C-Multizone cooling,
MZ-H-Multizone heating)
Glass/Floor Area: 0.06 Total as -built points: 9667.60 Y PASS
Total base points: 10844.00
1 hereby certify that the plans and specifications covered
by this calculation are in compliance with the Florida
Energy Code.
PREPARED BY: Adfe-1 Sod F.55 .4 Zut
DATE: ? SOF
I hereby certify that this building, as designed, is in
compliance with the Florida Energy ode
OWNER/AGENT:
DATE:
Cap: 21.5 kBtu/hr _
SEER- 10.00
Cap: 17.0 kBtu/hr
COP: 1.00
Cap: 30.0 gallons
EF: 0.89
Review of the plans and
ZtE sT
aT�o
specifications covered by this
o� =
calculation indicates compliance
with the Florida Energy Code.
Before is completed
construction
a
this building will be inspected for
compliance with Section 553.908
•COD
Florida Statutes.
{NE
BUILDING OFFICIAL:
DATE:
EnergyGauge® (Version: FLRCNA-200)
FORM 60OA-97
SUMMER CALCULATIONS
Residential Whole Building Performance Method A - Details
ADDRESS: , PORT ST LUCIE, FL, PERMIT #:
BASE
AS -BUILT
GLASS TYPES
.18 X Conditioned X BSPM =
Points -
Overhang
Floor Area
Type/SC Ornt Len
Hgt Area X SPM
X SOF
= Points
'.18 894.0
42.08
6771.1
Single, Clear E 1.0
5.5 27.0 59.31
0.96
1543.6
Single, Clear E 1.0
5.5 20.0 59.31
0.96
1143.4
Single, Clear S 1.0
4.3 7.0 44.66
0.88
274.5
As -Built Total:
54.0
2961.4
WALL TYPES
Area X BSPM
= Points
Type
R-Value Area
X SPM
= Points
Adajcent
304.5 0.7
213.1
Concrete, Int Insul, Exterior
3.0 450.0
1.40
630.0
Exterior
450.0 1.90
855.0
Concrete, Int Insul, Adjacent
3.0 304.5
0.70
213.1
Base Total:
754.5
1068.1
As -Built Total:
754.5
843.2
DOOR TYPES
Area X BSPM
= Points
Type
Area
X SPM
= Points
Adjacent
21.0 1.60
33.6
Adjacent Wood
21.0
2.40
50.4
Exterior
0.0 0.00
0.0
Base Total:
21.0
33.6
As -Built Total:
21.0
50.4
CEILING TYPES Area X BSPM
= Points
Type
R-Value Area
X SPM
= Points
Under Attic
0.0 0.00
0.0
Base Total:
0.0
0.0
As -Built Total:
0.0
0.0
FLOOR TYPES
Area X BSPM
= Points
Type
R-Value Area
X SPM
= Points
Slab
98.0(p) -31.8
-3116.4
Slab -On -Grade Edge Insulation
0.0 98.0(p)
-31.90
-3126.2
Raised
0.0 0.00
0.0
Base Total:
-3116.4
As -Built Total:
-3126.2
INFILTRATION
Area X BSPM
= Points
Area X SPM
= Points
894.0 14.31
12793.1
894.0
14.31
12793.1
Summer Base Points:
17549.6
Summer As -Built Points:
13521.9
Total Summer
X System =
Cooling
Total X Cap X
Duct X System X
Credit
= Cooling
Points
Multiplier
Points
Component Ratio
Multiplier Multiplier
Multiplier
Points
13521.9 1.000
0.930 0.341
1.000
4288.2
17549.6
0.3577
6277.6
13521.9 1.00
0.930 0.341
1.000
4288.2
EnergyGaugeTm DCA Form 60OA-97
FORM 60OA-97
WINTER CALCULATIONS
Residential Whole Building Performance Method A - Details
ADDRESS: , PORT ST LUCIE, FL, PERMIT #:
BASE
AS -BUILT
GLASS TYPES
.18 X Conditioned X BWPM =
Points.
Overhang
Floor Area
Type/SC Ornt Len
Hgt Area X WPM X
WOF
= Points
.18 894.0
4.79
770.7
Single, Clear E 1.0
5.5 27.0 9.96
1.01
271.6
Single, Clear E 1.0
5.5 20.0 9.96
1.01
201.2
Single, Clear S 1.0
4.3 7.0 7.73
1.04
56.5
As -Built Total:
54.0
529.3
WALL TYPES
Area X
BWPM
= Points
Type
R-Value Area X
WPM
= Points
Adajcent
304.5
1.8
548.1
Concrete, Int Insul, Exterior
3.0 450.0
3.80
1710.0
Exterior
450.0
2.00
900.0
Concrete, Int Insul, Adjacent
3.0 304.5
2.30
700.3
Base Total:
754.6
1448.1
As -Built Total:
754.5
2410.4
DOOR TYPES
Area X
BWPM
= Points
Type
Area X
WPM
= Points
Adjacent
21.0
4.00
84.0
Adjacent Wood
21.0
5.90
123.9
Exterior
0.0
0.00
0.0
Base Total:
21.0
84.0
As -Built Total:
21.0
123.9
CEILING TYPES Area X
BWPM
= Points
Type
R-Value Area X
WPM
= Points
Under Attic
0.0
0.00
0.0
Base Total:
0.0
0.0
As -Built Total:
0.0
0.0
FLOOR TYPES
Area X
BWPM
= Points
Type
R-Value Area X
WPM
= Points
Slab
98.0(p)
-1.9
-186.2
Slab -On -Grade Edge Insulation.
0.0 98.0(p)
2.50
245.0
Raised
0.0
0.00
0.0
Base Total:
-186.2
As -Built Total:
245.0
INFILTRATION
Area X
BWPM
= Points
Area X
WPM
= Points
894.0
-0.28
-250.3
894.0
-0.28
-250.3
Winter Base Points:
1866.3
Winter As -Built Points:
3058.3
Total Winter X
System
= Heating
Total X Cap X
Duct X System. X
Credit =
Heating
Points
Multiplier
Points
Component Ratio
Multiplier Multiplier Multiplier
Points
3058.3 1.000
0.930 1.000
1.000
2844.2
1866.3
1.0730
2002.6
3058.3 1.00
0.930 1.000
1.000
2844.2
EnergyGaugeTm DCA Form 60OA-97
FORM 60OA-97
WATER HEATING & CODE COMPLIANCE STATUS
Residential Whole Building Performance Method A - Details
ADDRESS: , PORT ST LUCIE, FL, PERMIT #:
BASE AS -BUILT
VVATER HEATING
Number of X Multiplier = Total Tank EF Number of X Tank X Multiplier X Credit = Total
Bedrooms Volume Bedrooms Ratio Multiplier
1 2564.00 2564.0 30.0 0.89 1 1.00 2535.19 1.00 2535.2
As -Built Total: 2535.2
CODE
COMPLIANCE
STATUS
BASE
AS -BUILT
Cooling + Heating +
Points Points
Hot Water
Points
= Total
Points
Cooling
Points
+ Heating + Hot Water = Total
Points Points Points
6277.5 2002.6
2564.0
10844.0
4288.2
2844.2 2535.2 9667.6
PASS
EnergyGaugeTm DCA Form 60OA-97
FORM 60OA-97
Code Compliance Checklist
Residential Whole Building Performance Method A - Details
ADDRESS: , PORT ST LUCIE, FL, PERMIT #:
6A-21 INFILTRATION REDUCTION COMPLIANCE CHECKLIST
COMPONENTS
SECTION
REQUIREMENTS FOR EACH PRACTICE
CHECK
Exterior Windows & Doors
606.1.ABC.1.1
Maximum:.3 cfm/s .ft. window area; .5 cfm/s .ft. door area.
Exterior & Adjacent Walls
606.1.ABC.1.2.1
Caulk, gasket, weatherstrip or seal between: windows/doors & frames, surrounding wall;
foundation & wall sole or sill plate; joints between exterior wall panels at corners; utility
penetrations; between wall panels & top/bottom plates; between walls and floor.
EXCEPTION: Frame walls where a continuous infiltration barrier is installed that extends
from and is sealed to the foundation to the top plate.
Floors
606.1.ABC.1.2.2
Penetrations/openings >1/8" sealed unless backed by truss or joint members.
EXCEPTION: Frame floors where a continuous infiltration barrier is installed that is sealed
to the perimeter, penetrations and seams.
Ceilings
606.1.ABC.1.2.3
Between walls & ceilings; penetrations of ceiling plane of top floor; around shafts, chases,
soffits, chimneys, cabinets sealed to continuous air barrier; gaps in gyp board & top plate;
•
attic access. EXCEPTION: Frame ceilings where a continuous infiltration barrier is
installed that is sealed at the perimeter, at penetrations and seams.
Recessed Lighting Fixtures
606.1.ABC.1.2.4
Type IC rated with no penetrations, sealed; or Type IC or non -IC rated, installed inside a
sealed box with 1/2" clearance & 3"from insulation; or Type IC rated with < 2.0 cfm from
conditioned space, tested.
Multi -story Houses
606.1.ABC.1.2.5
Air barrier on perimeter of floor cavity between floors.
Additional Infiltration reqts
606.1.ABC.1.3
Exhaust fans vented to outdoors, dampers; combustion space heaters comply with NFPA,
have combustion air.
&A_99 n rUCO 001=09`0I01rI\/C IIACACI IRGC /mncf ha ma4 nr avraarlarl by all ra4irla_nCP_C _I
COMPONENTS
SECTION
REQUIREMENTS
CHECK
Water Heaters
612.1
Comply with efficiency requirements in Table 6-12. Switch or clearly marked circuit
breaker electric or cutoff as must be provided. External or built-in heat trap required.
Swimming Pools & Spas
612.1
Spas & heated pools must have covers (except solar heated). Non-commercial pools
must have a pump timer. Gas spa & pool heaters must have a minimum thermal.
efficiency of 78%.
Shower heads
612.1
Water flow must be restricted to no more than 2.5 gallons per minute at 80 PSIG.
Air Distribution Systems
610.1
All ducts, fittings, mechanical equipment and plenum chambers shall be mechanically
attached, sealed, insulated, and installed in accordance with the criteria of Section 610.
Ducts in unconditioned attics: R-6 min. insulation.
HVAC Controls
607.1
Separate readily accessible manual or automatic thermostat for each system.
Insulation
604.1, 602.1
Ceilings -Min. R-19. Common walls -Frame R-11 or CBS R-3 both sides.
Common ceiling & floors R-11.
EnergyGaugeTm DCA Form 60OA-97 EnergyGauge®/FlaRES'97 FLRCNA-200
I
I
ENERGY PERFORMANCE LEVEL (EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE SCORE* = 84.1
The higher the score, the more efficient the home.
RICH PROPERTIES,, PORT ST LUCIE, FL,
1. New construction or existing
New _
12. Cooling systems
2; Single family or multi -family
Multi -family _
a. Central Unit
Cap: 21.5 kBtu/hr _
3. Number of units, if multi -family
1 _
SEER: 10.00 _
4. Number of Bedrooms
1 _
b. N/A
5. Is this a worst case?
Yes
6. Conditioned floor area (ft)
fi7kft
c. N/A
_
7. Glass area & type
a. Clear - single pane
54.0 ft2 _
13. Heating systems
b. Clear - double pane
0.0 ft2 _
a. Electric Strip
Cap: 17.0 kBtu/hr _
c. Tint/other SC/SHGC - single pane
0.0 ft2 _
COP: 1.00 _
d. Tint/other SC/SHGC - double pane
0.0 ft2
b. N/A
_
8, Floor types
_
—
a. Slab -On -Grade Edge Insulation
R=0.0, 98.0(p) ft _
c. N/A
_
b. N/A
_
—
c. N/A
14. Hot water systems'
9. Wall types
_
a. Electric Resistance
Cap: 30.0 gallons _
a. Concrete, Int Insul, Exterior
R=3.0, 450.0 ft2 _
EF: 0.89 _
b. Concrete, Int Insul, Adjacent
R=3.0, 304.5 ft2 _
b. N/A
_
c. N/A
_
d. N/A
_
c. Conservation credits
e. N/A
(HR-Heat recovery, Solar
10. Ceiling types
_
DHP-Dedicated heat pump)
a. N/A
_
15. HVAC credits
b. N/A
_
(CF-Ceiling fan, CV -Cross ventilation,
c. N/A
HF-Whole house fan,
11. Ducts
_
PT -Programmable Thermostat,
a. Sup: Con. Ret:.Con. AH: Interior
Sup. R=4.2, 30.0 ft _
RB-Attic radiant barrier,
b. N/A
MZ-C-Multizone cooling,
MZ-H-Multizone heating)
I certify that this home has complied with the Florida Energy Efficiency Code For Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant features.
Builder Signature: Date:
Address of New Home:
City/FL Zip:
.TIiE ST,91�0��
a
�01) WF �&o
*NOTE: The home's estimated energy performance score is only available through the FLARES computer program.
This is not a Building Energy Rating. If your score is 80 or greater (or 86 for a US EPADOE EnergyStar7mdesignation),
your home may qualify for energy efficiency mortgage (EEM incentives if you obtain a Florida Energy Gauge Rating.
Contact the Energy Gauge Hotline at 4071638-1492 or see the Energy Gauge web site at www.fsec. ucf edu for
information and a list of certified Raters. For information about Florida's Energy Efficiency Code For Building Construction,
contact the Department of Community Affairs at 8501487-1824.
Energy.Gauge® (Version: FLRCNA-200)
RIGHT-J LOAD AND EQUIPMENT SUMMARY,
Entire House
FES, INC. Job: 01089 4121199
34 N.W. 168TH. STREET, NORTH MIAMI BEACH, FL 33169 Phone: 305-653-0212 Fax: 305-653-0232
Project Information
For: SAVANNA CLUB
FLAN Al LYP_., F=
Phone: WC=e
Notes:
Design Information
Weather: Fort Lauderdale, FL, US
Winter Design Conditions
Summer Design Conditions
Outside db
46
OF
Outside db
91
OF
Inside db
71
OF
Inside db
75
OF
Design TD
25
OF
Design TD
16
OF
Daily range
M
Relative humidity
50
%
Moisture difference
60
gr/lb
Heating Summary
Sensible Cooling Equipment Load Sizing
Building heat loss
10251
Btuh
Structure
8489
Btuh
Ventilation air
0
cfm
Ventilation
1320
Btuh
Ventilation air loss
0
Btuh
Design temperature swing
3.0
OF
Design heat load
10251
Btuh
Use mfg. data
n
Rate/swing multiplier
0.96
Infiltration
Total sens. equip. load
9416
Btuh
Method
Simplified
Latent Cooling Equipment Load Sizing
Construction quality
Average
Fireplaces
0
Internal gains
460
Btuh
Ventilation
3048
Btuh
Hea ing�—Cooling
�8'94
Infiltration
2730
Btuh
Area (ftz)
894�
Total latent equip. load
6239
Btuh
Volume (ft')
8046
8046
Air changes/hour
1.2
0.5
Total equipment load
15655
Btuh
Equiv. AVF (cfm)
161
67
Heating Equipment Summary
Cooling Equipment Summary
Make n/a
Make
Trade
Trade "
n/a
Efficiency
100.0 EFF
Efficiency
0.0 EER
- Heating input
0
Btuh
Sensible cooling
0
Btuh
Heating output
0
Btuh
Latent cooling
0
Btuh
Heating temp rise
0
OF
Total cooling
0
Btuh
Actual heating fan
367
cfm
Actual cooling fan
367
cfm
Heating air flow factor
0.036
cfm/Btuh
Cooling air flow factor
0.043
cfm/Btuh
Space thermostat
Load sensible heat ratio
61
%
Printout certified by ACCA to meet all requirements of Manual J 7th Ed.
wng f-titsoft Right-Sulte Residential^" 5.0.45 RSR23656 2001-Jul-05 09:06:44
ACCK H:1Wrightsoft LOAD CALCS\SAVANNA CLUB\PLAN Al BOT.rsr Page 1
RIGHT-J CALCULATION PROCEDURES A, B, C, D
0 Entire House
FES, INC. Job: 01089 4121199
34 N.W. 168TH. STREET, NORTH MIAMI BEACH, FL 33169 Phone: 305-653-0212 Fax: 305-653-0232
Procedure A - Winter Infiltration HTM Calculation*
1. Winter infiltration AVF
1.2 ach x 8046 ft3 x 0.0167 = 161 cfm
2. Winter infiltration load
1.1 x 161 cfm x 25 OF Winter TD = 4434 Btuh
3. Winter infiltration HTM
4434 Btuh / 75 ft2 Total window = 59.1 Btuh/ft2
and door area
Procedure B - Summer Infiltration HTM Calculation
1. Summer infiltration AVF
0.5 ach x 8046 ft3 x 0.0167 = 67 cfm
2. Summer infiltration load
1.1 x67 cfm x 16 OF SummerTD = 1182 Btuh
3. Summer infiltration HTM
1182 Btuh / 75 ft2 Total window = 15.8 Btuh/ft2
and door area
Procedure C - Latent Infiltration Gain
0.68 x60 gr/lb moist.diiff. x 67 cfm = 2730 Btuh
eroceaure u - tgwpment sizing Loaas
1. Sensible sizing load
Sensible ventilation load
1.1 x 75 cfm vent. x 16 OF Summer TD =
1320
Btuh
Sensible load for structure (Line 19) +
8489
Btuh
Sum of ventilation and structure loads =
9809
Btuh
Rating and temperature swing multiplier x
0.96
Equipment sizing load - sensible =
9416
Btuh
2. Latent sizing load
Latent ventilation load
0.68 x 75 cfm vent. x 60 gr/lb moist.diff. = w
3048
Btuh
Internal loads = 230 Btuh x 2 people +
460
Btuh
Infiltration load from Procedure C +
2730
Btuh
Equipment sizing load - latent =
6239
Btuh
*Construction Quality is: a No. of Fireplaces is: 0
Bold/italic values have been manually overridden
Printout certified by ACCA to meet all requirements of Manual J 7th Ed.
, = wnghtsoft Right-SuiteResiderdialTM 5.0.45RSR23656 2001-Jul-0509:06:44
H:\Wrightsoft LOAD CALCS\SAVANNA CLUB\PLAN Al BOT.rsr Page 1
0)
co
cm
0
C
0
�7
IMIli
HIM
Mill
0
o
•« Zvi
o
O
W0Moo0
0)00
rntnnOoo
00000O
000000
�
00000)0000)r-
•♦
i i«
{z� •y X
W
W
n T W
W W m M
L U
i •
i t
♦
♦«
V' O
my
r O O O O O
N O O
O N W 0 0 0
0 0 0 0 0 0
t0 0 0 0 o 0
v
O O O r
n
mWW�
isj
r
$ $
�S
N
ry
rn
v
o
co
a) am)�
x
« «L «
s .
«SiiSS:
Q X M
Z 0
n COO 00
V 0 0 0 0 0
n 0 n 0 0 0
0 0
O V to 0 0 O
0 0 0 0 0 0
W 0 0 0 0 0
to
o
N r c
J
n W N
p
st
N
to to O
v co
0)
n
O
O O z
W)QMOOO
WOO
nt0 fh000
OOOOOO
000000
N
oO W 000W n
D) O
W
0) Q)
W
cOO N ' r vcc )
W W
•«`
« «
7
m
r 0 0 0 0 0
N O O
O N W 0 0 0
0 0 0 0 0 0
tp 0 0 0 0 0
`7
O O O r
n
O
W
'O
}x ss
p {s� j ty$
N
�.N-•'MV
Do
W
M
N N
O««
* j N
70
J x
i i
1 ««
N
n c000O
na I- 000
00
Ovtn 000
000000
WO0000
to
o
Nr o
•
nWN
300000
V
N
to WO
0)
n
O
OO
v
W W W O O O
W O W 0 0 0
O 0 0
OR OR W RR 0
r 0 0 0 0 0
O N 0 0 0 0
W
0 0
O)
rr 0r 00
« « « « « «
rCOGOC
01r0
r r G-GO
N00000
ONOC 00
tl')
MN
�O
N Goc
r
r
O
x
W
(D c)vO)00
rr 0000
to 00
W M"t0)00
M00000
Mc00o00
r
C
O)
M cV rC C G
NN O C O C
O
cd N— 00 0
r 00 O O C
N V 0 0 0 0
0
} J
EL
fA0
[aUZU
�NMM
cD cd
❑Q
00
cv0ZU
vNMM
❑
W
�Q
N0)
c6
c
LZ cA-5
D7 N
+
O._
W 3 0
UZ
rrr
rW
ZZ Eo
rr
rrrr
r
+. C
aoi n� c
WM U'D Q
Cc U•O 0)u-.
ma C.)W.0
0,00-
W.0 U'D 0
W.0U•O mw
.p y
O•@ a
LLQ �•� r.V..
CD
nIS y 0
co
•l0 O C
om
.0 p+j
rnCO
�
c
QOO!
Jg2
W
�
O
.o
E
$
��
ai
Li =
zov
O
o mo
v
m
O
p
0rE
a
N
WO
a. a
C
am5
Om=
•
L
cSo.
'
jrnx
j O
O
ZC.
200CN
LL!�C
QJJ❑ZJQU g
`-
3DX1
(aQ
S cAJJ ❑�--Q
C9WcC-
T
co
0)
O
N
M v to
W n c0 0) 0
FORM 60OA-97
FLORIDA_ENERGY EFFICIENCY CODE
POR BUILDING CONSTRUCTION
Florida Department of Community Affairs
Residential Whole Building Performance Method A
Project Name: SAVANA CLUB APTPAIT;A2=B0T.1 Builder:
Address: Permitting Office: PcR'r vr--<uc►e
City, State: PORT ST LUCIE, FL Permit Number:
Owner: RICH PROPERTIES Jurisdiction Number: 6 6/Roo
Climate Zone: Central
1. New construction or existing
New _
12. Cooling systems
2. Single family or multi -family
Multi -family _
a. Central Unit
3. Number of units, if multi -family
1 _
4. Number of Bedrooms
1 _
b. N/A
5. Is this a worst case?
Yes _
6. Conditioned floor area (ft2)
914 ft2
c. N/A
7. Glass area & type
a. Clear - single pane
54.0 ft2 _
13. Heating systems
- b. Clear - double pane
0.0 ft2 _
a. Electric Strip '
c. Tintlother SC/SHGC - single pane
0.0 ft2 _
d. Tintlother SC/SHGC - double pane
0.0 ft2
b. N/A
S. Floor types
_
a. Slab -On -Grade Edge Insulation
R=0.0, 46.0(p) ft _
c. N/A
b. N/A
_
c. N/A
14. Hot water systems
9. Wall types
_
a. Electric Resistance
a. Concrete, Int Insul, Exterior
R=3.0, 450.0 ft2 _
b. Concrete, Int Insul, Adjacent
R=3.0, 289.0 ft2 _
b. N/A
c. N/A
_
d. N/A
_
c. Conservation credits
e. N/A
(HR-Heat recovery, Solar
10. Ceiling types
_
DHP-Dedicated heat pump)
a. N/A
_
15. HVAC credits
b. N/A
_
(CF-Ceiling fan, CV -Cross ventilation,
c. N/A
HF-Whole house fan,
11. Ducts
_
PT -Programmable Thermostat,
a. Sup: Con. Ret: Con. AH: Interior
Sup. R=4.2, 40.0 ft _
RB-Attic radiant barrier,
b. N/A
MZ-C-Multizone cooling,
MZ-H-Multizone heating)
Glass/Floor Area: 0.06 Total gas -built points: 9994.90
Total base points: 11677.00 PASS
I hereby certify that the plans and specifications covered
by this calculation are in compliance with the Florida
Energy Code.
PREPARED BY: AlLcrt !NC -
DATE: Spa/
I hereby certify that this building, as designed, is in
compliance with the Florida, E'n y gpfle.
OWNER/AGENT:
DATE:
Cap: 21.9 kBtu/hr _
SEER: 10.00
Cap: 17.0 kBtu/hr _
COP: 1.00
Cap: 30.0 gallons
EF: 0.89
lReview of the plans and
z sT
specifications covered by thisaT�o
'. A�
calculation indicates compliance
y,,,`'''' _
with the Florida Energy Code.
Before construction is completed
this building will be inspected for
compliance with Section 553.908
�•�on�
Florida Statutes.
WE
BUILDING OFFICIAL:
DATE:
EnergyGauge® (Version: FLRCNA-200)
FORM 60OA-97
FLORIDA ENERGY EFFICIENCY CODE
FOR BUILDING CONSTRUCTION
Florida Department of Community Affairs
Residential Whole Building Performance Method A
Project Name: SAVANA CLUB APUNIT A2=BOT] Builder:
Address: Permitting Office:
City, State: PORT ST LUCIE, FL Permit Number:
Owner: RICH PROPERTIES Jurisdiction Number:
Climate Zone: Central
1.
New construction or existing
New _
12. Cooling systems
2.
Single family or multi -family
Multi -family _
a. Central Unit
3.
Number of units, if multi -family
1 _
4.
Number of Bedrooms
1 _
b. N/A
5.
Is this a worst case?
Yes _
6.
Conditioned floor area (ft2)
C914V
c. N/A
7.
Glass area & type
_
a. Clear - single pane
54.0 ft2 _
13. Heating systems
b. Clear - double pane
0.0 ft2 _
a. Electric Strip
c. Tint/other SC/SHGC - single pane
0.0 ft2 _
d. Tintlother SC/SHGC - double pane
0.0 ft2
b. N/A
8.
Floor types
_
a. Slab -On -Grade Edge Insulation
R=0.0, 46.0(p) ft _
c. N/A
b. N/A
c. N/A
14. Hot water systems
9.
Wall types
_
a. Electric Resistance
a. Concrete, Int Insul, Exterior
R=3.0, 450.0 ft2 _
b. Concrete, Int Insul, Adjacent
R=3.0, 289.0 ft2 _
b. N/A
c. N/A
d. N/A
_
c. Conservation credits
e. N/A
(HR-Heat recovery, Solar
10. Ceiling types
_
DHP-Dedicated heat pump)
a. N/A
_
15. HVAC credits
b. N/A
_
(CF-Ceiling fan, CV -Cross ventilation,
c. N/A
HF-Whole house fan,
11. Ducts
_
PT -Programmable Thermostat,
a. Sup: Con. Ret: Con. AH: Interior
Sup. R=4.2, 40.0 ft _
RB-Attic radiant barrier,
b. N/A
MZ-C-Multizone cooling,
MZ-H-Multizone heating)
a
Glass/Floor Area: 0.06 Total as -built points: 9994.90 PASS
Total base points: 11677.00
I hereby certify that the plans and specifications covered
by this calculation are in compliance with the Florida
Energy Code.
PREPARED BY: 410't qL4 F .9 IAVc-
DATE: :5 a
I hereby certify that this building, as designed, is in
compliance with the Florida !Enqpgy
ode.
OWNER/AGENT:
DATE:
Cap: 21.9 kBtu/hr
SEER: 10.00
Cap: 17.0 kBtu/hr _
COP: 1.00
Cap: 30.0 gallons _
EF: 0.89
Review of the plans and
CTUE STAY
specifications covered by this
calculation indicates compliance
with the Florida Energy Code.
Before construction is completed
A.
this building will be inspected for
compliance with Section 553.908
�•oon�5'�
Florida Statutes.
eve
BUILDING OFFICIAL:
DATE:
EnergyGauge® (Version: FLRCNA-200)
FORM 60OA-97
SUMMER CALCULATIONS
Residential Whole Building Performance Method A - Details
ADDRESS:, PORT ST LUCIE, FL, PERMIT #:
BASE
AS -BUILT
GLASS TYPES
.18 X Conditioned X BSPM =
Points •
Overhang
Floor Area
Type/SC Ornt Len
Hgt Area X SPM
X SOF
= Points
.18 914.0
42.08
6922.6
Single, Clear E 2.0
5.0 27.0 59.31
0.81
1290.2
Single, Clear E 2.0
5.0 20.0 59.31
0.81
955.7
Single, Clear S 2.0
3.0 7.0 44.66
0.63
197.1
As -Built Total:
54.0
2443.1
WALL TYPES
Area X BSPM
= Points
Type
R-Value Area
X SPM
= Points
Adajcent
289.0 0.7
202.3
Concrete, Int Insul, Exterior
3.0 450.0
1.40
630.0.
.Exterior
450.0 1.90
855.0
Concrete, Int Insul, Adjacent
3.0 289.0
0.70
202.3
Base Total:
739.0
1057.3
As -Built Total:
739.0
832.3
DOOR TYPES
Area X BSPM
= Points
Type
Area
X SPM
= Points
Adjacent
21.0 1.60
33.6
Adjacent Wood
21.0
2.40
50.4
Exterior
0.0 0.00
0.0
Base Total:
21.0
33.6
As -Built Total:
21.0
50.4
CEILING TYPES Area X BSPM
= Points
Type
R-Value Area
X SPM
= Points
Under Attic
0.0 0.00
0.0
Base Total:
0.0
0.0
As -Built Total:
0.0
0.0
FLOOR TYPES
Area X BSPM
= Points
Type
R-Value Area
X SPM
= Points
Slab
46.0(p) -31.8
-1462.8
Slab -On -Grade Edge Insulation
0.0 46.0(p)
-31.90
-1467.4
Raised
0.0 0.00
0.0
Base Total:
-1462.8
As -Built Total:
-1467.4
FNFILTRATION
Area X BSPM
= Points
Area X SPM
= Points
914.0 14.31
13079.3
914.0
14.31
13079.3
Summer Base Points:
19630.0
Summer As -Built Points:
14937.7
Total Summer
X System =
Cooling
Total X Cap X
Duct X System X
Credit
= Cooling
Points
Multiplier
Points
Component Ratio
Multiplier Multiplier
Multiplier
Points
14937.7 1.000
1
0.930 0.341
1.000
4737.2
19630.0
0.3577
7021.7
14937.7 1.00
0.930 0.341
1.000
4737.2
EnergyGaugeTM DCA Form 60OA-97
FORM 60OA-97
WINTER CALCULATIONS
Residential Whole Building Performance Method A - Details
ADDRESS:, PORT ST LUCIE, FL, PERMIT #:
BASE
AS -BUILT
GLASS TYPES
.18 X Conditioned X BWPM
= Points,
Overhang
Floor Area
Type/SC Ornt Len
Hgt Area X WPM X WOF
= Points
18 914.0
4.79
788.0
Single, Clear E 2.0
5.0 27.0 9.96
1.04
280.3
Single, Clear E 2.0
5.0 20.0 9.96
1.04
207.6
Single, Clear S 2.0
3.0 7.0 7.73
1.51
81.8
As -Built Total:
64.0
569.7
WALL TYPES
Area X BWPM
= Points
Type
R-Value Area X
WPM
= Points
Adajcent
289.0 1.8
520.2
Concrete, Int Insul, Exterior
3.0 450.0
3.80
1710.0
Exterior
450.0 2.00
900.0
Concrete, Int Insul, Adjacent
3.0 289.0
2.30
664.7
Base Total:
739.0
1420.2
As -Built Total:
739.0
2374.7
DOOR TYPES
Area X BWPM
= Points
Type
Area X
WPM
= Points
Adjacent
21.0 4.00
84.0
Adjacent Wood
21.0
5.90
123.9
Exterior
0.0 0.00
0.0
Base Total:
21.0
84.0
As -Built Total:
21.0
123.9
CEILING TYPES Area X BWPM
= Points
Type
R-Value Area X
WPM
= Points
Under Attic
0.0 0.00
0.0
Base Total:
0.0
0.0
As -Built Total:
0.0
0.0
FLOOR TYPES
Area X BWPM
= Points
Type
R-Value Area X
WPM
= Points
Slab
46.0(p) -1.9
-87.4
Slab -On -Grade Edge Insulation
0.0 46.0(p)
2.50
115.0
Raised
0.0 0.00
0.0
Base Total:
-87.4
As -Built Total:
115.0
;NFILTRATION
Area X BWPM
= Points
Area X
WPM
= Points
914.0 -0.28
-255.9
914.0
-0.28
-255.9
Winter Base Points:
1948.9
Winter As -Built Points:
2927.4
Total Winter X
System = Heating
Total X Cap X
Duct X System X
Credit =
Heating
Points
Multiplier
Points
Component Ratio
Multiplier Multiplier Multiplier
Points
2927.4 1.000
0.930 1.000
1.000
2722.5
1948.9
1.0730
2091.1
2927.4 1.00
0.930 1.000
1.000
2722.5
EnergyGaugeTm DCA Form 60OA-97
FORM 60OA-97
WATER HEATING & CODE__ COMPLIANCE STATUS
Residential Whole Building Performance Method A - Details
ADDRESS:, PORT ST LUCIE, FL, PERMIT #:
BASE AS -BUILT
WATER HEATING
Number of X Multiplier = Total Tank EF Number of X Tank X Multiplier X Credit = Total
Bedrooms Volume Bedrooms Ratio Multiplier
1 2564.00 2564.0 30.0 0.89 1 1.00 2535.19 1.00 2535.2
As -Built Total: 2535.2
CODE COMPLIANCE STATUS
BASE
AS -BUILT
Cooling + Heating + Hot Water = Total
Points Points Points Points
7021.7 2091.1 2564.0 11676.8
4737.2 2722.5 2535.2 9994.9
PASS
q" 01JOE ST9?�0��
I
a
.r,�coD WE����
EnergyGaugeTTM DCA Form 60OA-97
FORM 60OA-97
_Code Compliance Checklist _
Residential Whole Building Performance Method A - Details
ADDRESS:, PORT ST LUCIE, FL, PERMIT #:
6A-21 INFILTRATION REDUCTION COMPLIANCE CHECKLIST
COMPONENTS
SECTION
REQUIREMENTS FOR EACH PRACTICE
CHECK
Exterior Windows & Doors
606.1.ABC.1.1
Maximum:.3 cfm/s .ft. window area; .5 cfm/s .ft. door area.
Exterior & Adjacent Walls
606.1.ABC.1.2.1
foundation & wall sole or sill plate; joints between exterior wall panels at comers; utility
penetrations; between wall panels & top/bottom plates; between walls and floor.
from, and is sealed to, the foundation to the top plate.
Floors
606.1.ABC.1.2.2
Penetrations/openings >1/8" sealed unless backed by truss or joint members.
EXCEPTION: Frame floors where a continuous infiltration barder.is installed that is sealed
to the perimeter, Penetrations and seams.
Ceilings
606.1.ABC.1.2.3
Between walls & ceilings; penetrations of ceiling plane of top floor, around shafts, chases,
soffits, chimneys, cabinets sealed to continuous air barrier; gaps in gyp board & top plate;
installed that is sealed at the perimeter, at penetrations and seams.
Recessed Lighting Fixtures
606.1.ABC.1.2.4
conditioned space, tested.
Multi -story Houses
606.1.ABC.1.2.5
Air barrier on perimeter of floor cavity between floors.
Additional Infiltration reqts
606.1.ABC.1.3
have combustion air.
RA-99 (ATI41=R PRESCRIPTIVE MFASI IRFS fmnct ha mat nr pxr_pprlpcl by all rPsidpnr_Ps_1
COMPONENTS
SECTION
REQUIREMENTS
CHECK
Water Heaters
612.1
breaker electric or cutoff as must be provided. External or built-in heat trap required.
Swimming Pools & Spas
612.1
must have a pump timer. Gas spa & pool heaters must have a minimum thermal
efficiency of 78%.
Shower heads
612.1
Water flow must be restricted to no more than 2.5 gallons per minute at 80 PSIG.
Air Distribution Systems
610.1
attached, sealed, insulated, and installed in accordance with the criteria of Section 610.
Ducts in unconditioned attics: R-6 min. insulation.
HVAC Controls
607.1
Separate readily accessible manual or automatic thermostat for each system.
Insulation
604.1, 602.1
Ceilings -Min. R-19. Common walls -Frame R-11 or CBS R-3 both sides.
Common ceiling & floors R-11.
EnergyGaugeTM DCA Form 60OA-97 EnergyGauge®/FlaRES'97 FLRCNA-200
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE SCORE* = 84.6
The higher the score, the more efficient the home.
1. New construction or existing
.2. Single family or multi -family
3. Number of units, if multi -family
4. Number of Bedrooms
5. Is this a worst case?
6. Conditioned floor area (ft2)
7. Glass area & type
a. Clear - single pane
• b. Clear - double pane
c. Tintlother SC/SHGC - single pane
d. Tintlother SC/SHGC - double pane
'8. Floor types
a. Slab -On -Grade Edge Insulation
b. N/A
c. N/A
9. Wall types
a. Concrete, Int Insul, Exterior
b. Concrete, Int Insul, Adjacent
c. N/A
d. N/A
e. N/A
10. Ceiling types
a. N/A
b. N/A
c. N/A
11. Ducts
a. Sup: Con. Ret: Con. AH: Interior
b. N/A
RICH PROPERTIES,, PORT ST LUCIE, FL,
New _
12. Cooling systems
Multi -family _
a. Central Unit
1
1 _
b. N/A
Yes _
914 ftZ
c. N/A
54.0 ft2 _
13. Heating systems
0.0 ft2 _
a. Electric Strip
0.0 ft2 _
0.0 ft2
b. N/A
R=0.0, 46.0(p) ft _
c. N/A
14. Hot water systems
_
a. Electric Resistance
R=3.0, 450.0 ft2
R=3.0, 289.0 ft2 _
b. N/A
_
c. Conservation credits
(HR-Heat recovery, Solar
_
DHP-Dedicated heat pump)
_
15. HVAC credits
_
(CF-Ceiling fan, CV -Cross ventilation,
HF-Whole house fan,
_
PT -Programmable Thermostat,
Sup. R=4.2, 40.0 ft _
RB-Attic radiant barrier,
MZ-C-Multizone cooling,
MZ-H-Multizone heating)
I certify that this home has complied with the Florida Energy Efficiency Code For Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
.based on installed Code compliant features.
Builder Signature:
Address of New Home:
Date:
City/FL Zip:
Cap: 21.9 kBtu/hr _
SEER: 10.00
Cap: 17.0 kBtu/hr _
COP: 1.00
Cap: 30.0 gallons _
EF: 0.89 _
*NOTE. The home's estimated energy performance score is only available through the FLARES computer program.
TM
your home may qualify for energy efficiency mortgage (EEM incentives if you obtain a Florida Energy Gauge Rating.
Contact the Energy Gauge Hotline at 4071638-1492 or see the Energy Gauge web site at www.fsec. ucf edu for
information and a list of certified Raters. For information about Florida's Energy Efficiency Code For Building Construction,
contact the Department of Community Affairs at 8501487-1824.
EnergyGaugeO (Version: FLRCNA-200)
RIGHT-J LOAD AND EQUIPMENT SUMMARY
Entire House
FES, INC. Job: SAVANA CLUB UNIT
A2-130T 4/21199
34 N.W. 168TH. STREET, NORTH MIAMI BEACH, FL 33169 Phone: 305-653-0212 Fax: 305-653-0232
Project• •
For: SAVANNA CLUB
UNIT�A2=BOT; F`L'
Phone:-WC--W
Notes: SAVANA CLUB UNIT A2-BOT
Weather:
Winter Design Conditions
Outside db 47 OF
Inside db 71 OF
Design TD 24 OF
Heating Summary
Building heat loss 11406 Btuh
Ventilation air 0 cfm
Ventilation air loss 0 Btu
Design heat load 11406 Btu
Infiltration
Method Simplified
Construction quality Average
Fireplaces 0
West Palm Beach, FL, US
Summer Design Conditions
h
h
Outside db
90
OF
Inside db
75
OF
Design TD
15
OF
Daily range
L
Relative humidity
50
%
Moisture difference
61
gr/lb
Sensible Cooling Equipment
Load Sizing
Structure
10820
Btuh.
Ventilation
825
Btuh
Design temperature swing
3.0
OF
Use mfg. data
n
Rate/swing multiplier
0.95
Total sens. equip. load
11063
Btuh
Heating Cooling
Area (ft2)
914
914
Volume (ft')
8226
8226
Air changes/hour
1.0
0.5
Equiv. AVF (cfm)
137
69
Heating Equipment Summary
Make n/a
Trade
n/a
Efficiency
• Heating input
Heating output
Heating temp rise
Actual heating fan
Heating air flow factor
Space thermostat
0 Btuh
0 Btuh
0 OF
468 cfm
0.041 cfm/Btuh
Latent Cooling Equipment Load Sizing
Internal gains
460
Btuh
Ventilation
2088
Btuh
Infiltration
2868
Btuh
Total latent equip. load
5416
Btuh
Total equipment load 16479 Btuh
Cooling Equipment Summary
Make
Trade
Efficiency
0.0 EER
Sensible cooling
0
Btuh
Latent cooling
0
Btuh
Total cooling
0
Btuh
Actual cooling fan
468
cfm
Cooling air flow factor
0.043
cfm/Btuh
Load sensible heat ratio 68 %
Printout certified by ACCA to meet all requirements of Manual J 7th Ed.
�- Wrj0h t50ft Right -Suite Residentl;Iw 5.0.58 RSR23656 2001-Oct-10 11:55:02
/4CC% H:IWrightsoft LOAD CALCSISAVANNA CLUBIPLAN A2 BOT.rsr Page 1
RIGHT-J SHORT FORM
Entire House -- -
` FES, INC. Job: SAVANA CLUB UNIT
A2-130T 4121/99
34 N.W. 168TH. STREET, NORTH MIAMI BEACH, FL 33169 Phone: 305-653-0212 Fax: 305 65M232
Project• •
For: SAVANNA-CL-UBi
I�IT A2-BOT.; FL
Phone: WC-=W�
Design Information
Htg Clg Infiltration
Outside db (°F) 47 90 Method Simplified
Inside db (°F) 71 75 Construction quality Average
Design TD (OF) 24 15 Fireplaces 0
Daily range - L
Inside humidity (%) - 50
Moisture difference (gr/lb) - 61'
HEATING EQUIPMENT
COOLING EQUIPMENT
Make n/a
Make
Trade
Trade
n/a
Efficiency
100.0 EFF
Efficiency
0.0 EER
Heating input
0
Btuh
Sensible cooling
0
Btuh
Heating output
0
Btuh
Latent cooling
0
Btuh
Heating temperature rise
0
OF
Total cooling
0
Btuh
Actual heating fan
468
cfm
Actual cooling fan
468
cfm
Heating air flow factor
0.041
cfm/Btuh
Cooling air flow factor
0.043
cfm/Btuh
Space thermostat
Load sensible heat ratio
68
%
ROOM NAME
Area
Htg load
Clg load
Htg AVF
Clg AVF
(ft2)
(Btuh)
(Btuh)
(cfm)
(cfm)
UNIT-A2-130T
914
11406
10820
468
468
Entire House d
914
11406
10820
468
468
Ventilation air
0
825
Equip. @ 0.95 RSM
11063
Latent cooling
5416
Tyrw. r.
I nAA
44Ann
4MA70
AAR
AAR
Printout certified by ACCA to meet all requirements of Manual J 7th Ed.
wrightsoft Right -Suite Residential^" 5.0.58 RSR23656 2001-Oct-10 11:55:02
,(gip H:\Wrightsoft LOAD CALCS\SAVANNA CWB\PLAN A2 BOT.rsr Page 1
OP
`�.O. a
W
�5r
00
Dp
0
W
Ito
to
D..
Cl)
C
C)
C;
at CD
N
!D a
�CD
z�
to
Oo
1 it,
co
N
(0))
rn
0
co
V
T
CA
X�
A W N>
D—I�rrin
�orrtn
j
�p N�'�T
O N Z
0
Z
w x
O
S o
$ m
�03 X �
Ci.Z1� Z
(D w
N N (O
N tyI)
i
o
y p
CD
.O.
y
O N 7
N n
_�
w 7
c. N n
.%='p O
y
N
p O
0
N N .p-. 7•
.O+
N
y (D
(D N
7
3
y
C y
O m
y
f0 3 Cl)
y Z
C
•ch p x N
O N C7
y N7
7 7 Q
N n
On
0 0
O y
0 0
O.N
>> n
Nn
C
C-n
a O �. C
O'O
-0
3
N
y 7
N
m
j X r
O N=
�' w N
n
n
O
w
7 w
�+ 3 �-
8
+ N+
_ CD v
H E"r
"^N C10 O'w
^`N nt�O'w
�O n0 O'w
O vw
'*fD O.O vw
�`fD L10 o•w
r.�
A .w.m
n
zn
3� m
o``O)
a�
oq
mm
vPTCb-•
D�
o
CA to NA
czcm
00
Do
ayZc
C
� z
WNA
ozow
O(
7 0
N N
=
@
+
N
O
T
03
0 0 0 0 A co
0 0 0 0 0>
0 0 0> N W
G O W A N fJ1
O W>
O ?. G
P O O P P P
0 0 0 0
0 0 O> N W
C O tO A 1J fT
p
OO
_
OOOON O
OOOOON
00-+>NN
>
O NO
m N
OOO�O
n
' 00
OOOOODO
00000 W
OOW OIJ
O V A
000000
00 W� ON
?S
y 2)
7
0 o
O
V
f0
o
N A
t0 to W
CA
Cn
co
w
C
oss
o
01
OOOO O O
OOOOOO
O OOO A O
OO
OOO O O CT
OO OOOA
O Os O*S> V
(p
�}7 +�>N
i
7
f0
CD
A► i i i
A A
0)
.A.i
>_ Of
N
W
n
.00D
O
O
co
O O
0)0 O O O)
N
V
O
O OOO A O
O O O O O O
CT
OOO V V G)
coN
O O N
O OOOOA
C
i
$}
}S
0v
Am 003 NCD
•-'
n
j.�fD
W W
n
m O O O O Ot O O
W
O O O O O O
O 0 0 0 O O
OOO W 0
O O co
O OO m 0 CD
# ; i
i
3 �
C
.
0
V
w
c o z
0
O
V
W
o
OO OOO O
OOO o00
CID Cn CA
O 000 A O
N
OO N
W
OOOOOOt
to
OOOOOA
-W+ O
OSsO O» V
O 71
S
(0
C' c
pai
co
W
DO)
n
co O
O �
co
0 000 0)V
000 OA O
0 00000
O
000 V V C))
-0OOOOA
O O
i
O
NCA
j> O
j
W W
s ••♦
co 000 n 0s00
W
000000
000000
> f0
000 W O>
00 W
W co
OOPCDO w
s z
S S S
i 5
y
ii
d
O
C4
CD
cn
CP
n,;u
m �—
^Z^ —4
`I 0 L
5N�
00T
Vi
i 2
m
i
FORM 60OA-97
FLORIDA EN_ ERGY EFFICIENCY -.CODE
FOR BUILDING CONSTRUCTION
Florida Department of Community Affairs
Residential Whole Building Performance Method A
.Project Name: SAVANNA CLUB PLAN Al TO - Builder:
'Address: Permitting Office: FORT sT c.vcle
City,'State: PORT ST LUCIE, FL Permit Number:
Owner: RICH PROPERTIES Jurisdiction Number: 6CI200
Climate Zone: Central
1. New construction or existing
New _
12. Cooling systems
- 2. Single family or multi -family
Multi -family _
a. Central Unit
3. Number of units, if multi -family
1 -
4. Number of Bedrooms
1 _
b. N/A
5. Is this a worst case?
Yes
6. Conditioned floor area (ft2)
_
899_ 2 .
c. N/A
7. Glass area & type
_
a. Clear - single pane
54.0 ft2 _
13. Heating systems
b. Clear - double pane
0.0 ft2 _
a. Electric Strip
c. Tint/other SC/SHGC - single pane
0.0 ft2 _
d. Tintlother SC/SHGC - double pane
0.0 ft2
b. N/A
8. Floor types
_
a. Slab -On -Grade Edge Insulation
R=0.0, 98.0(p) ft _
c. N/A
b. N/A
_
c. N/A
14. Hot water systems
9. Wall types
_
a. Electric Resistance
a. Concrete, Int Insul, Exterior
R=3.0, 450.0 ft2
b. Concrete, Int Insul, Adjacent
R=3.0, 304.5 ft2 _
b. N/A
c. N/A
_
d. N/A
_
c. Conservation credits
e. N/A
(HR-Heat recovery, Solar
10. Ceiling types
_
DHP-Dedicated heat pump)
a. Under Attic
R=19.0, 894.0 ft2 _
15. HVAC credits
b. N/A
_
(CF-Ceiling fan, CV -Cross ventilation,
c. N/A
HF-Whole house fan,
11. Ducts
_
PT -Programmable Thermostat,
a. Sup: Con. Ret: Con. AH: Interior
Sup. R=4.2, 30.0 ft _
RB-Attic radiant barrier,
b. N/A
MZ-C-Multizone cooling,
MZ-H-Multizone heating)
Glass/Floor Area: 0.06 Total as -built points: 10811.00 y PASS
Total base points:,11611.00
I. hereby certify that the plans and specifications covered
by this calculation are in compliance with the Florida
'Energy Code.
PREPARED BY:
DATE:��%
I hereby certify that this building, as des' ned, is in
compliance with the Florda En de.
OWNERIAGENT:
DATE: I9 /i of
Cap: 21.5 kBtu/hr _
SEER: 10.00
Cap: 17.0 kBtu/hr _
COP: 1.00
Cap: 30.0 gallons
EF: 0.89
Review of the plans and
zOE Sr
aT�o
specifications covered by this
indicates
tio�` =
calculation compliance�•��D�
with the Florida Energy Code.
Before construction is completed
A' ""� "" ° °�
a
this building will be inspected for
compliance with Section 553.908
�•�oD�
Florida Statutes.
WF
BUILDING OFFICIAL:
DATE:
EnergyGauge® (Version: FLRCNA-200)
7 9
FORM 60OA-97
FLORIDA ENERGY EFFICIENCY CODE
FOR BUILDING CONSTRUCTION
Florida Department of Community Affairs
Residential Whole Building Performance Method A
Project Name: SAVANNA CLUB PLA ATTOP Builder:
Address: Permitting Office:
City, State: PORT ST LUCIE, FL Permit Number:
Owner: RICH PROPERTIES Jurisdiction Number:
Climate Zone: Central
1. New construction or existing
New -
12. Cooling systems
2. Single family or multi -family
Multi -family -
a. Central Unit
Cap: 21.5 kBtu/hr -
.-3. Number of units, if multi -family
1 _
SEER: 10.00 _
4. Number of Bedrooms
I -
b. N/A
-
5. Is this a worst case?
Yes _
-
6. Conditioned floor area (ft2)
894 $2
c. N/A
-
7. Glass area & type
-
-
a. Clear - single pane
54.0 ft2 -
13. Heating systems
- b. Clear - double pane
0.0 ft2 -
a. Electric Strip
Cap: 17.0 kBtu/hr -
c. Tint/other SC/SHGC - single pane
0.0 ft2 -
COP: 1.00 -
d. Tint/other SC/SHGC - double pane
0.0 ft2
b. N/A
-
-8. Floor types
-
-
a. Slab -On -Grade Edge Insulation
R=0.0, 98.0(p) ft -
c. N/A
-
b. N/A
-
-
c. N/A
14. Hot water systems
9. Wall types
-
a. Electric Resistance
Cap: 30.0 gallons -
a. Concrete, Int Insul, Exterior
R=3.0, 450.0 ft2 -
EF: 0.89 -
b. Concrete, Int Insul, Adjacent
R=3.0, 304.5 ft2 -
b. N/A
-
c. N/A
-
-
d. N/A
_
c. Conservation credits
-
e. N/A
(HR-Heat recovery, Solar
10. Ceiling types
-
DHP-Dedicated heat pump)
a. Under Attic
R=19.0, 894:0 ft2 -
15. HVAC credits
-
b. N/A
-
(CF-Ceiling fan, CV -Cross ventilation,
c. N/A
HF-Whole house fan,
11. Ducts
-
PT -Programmable Thermostat,
a. Sup: Con. Ret: Con. AH: Interior
Sup. R=4.2, 30.0 ft -
RB-Attic radiant barrier,
b. N/A
MZ-C-Multizone cooling,
MZ-H-Multizone heating)
Glass/Floor Area: 0.06 Total as -built points: 10811.00 PASS
Total base points: 11611.00
I hereby certify that the plans and specifications covered
by this calculation are in compliance with the Florida
Energy Code.
PREPARED BY:Alieel XX4 i-'F.S,, Tivc
DATE: I
hereby certify that this building, as desi ed, is in
compliance with the Florida En e C e.
OWNER/AGENT:
DATE: /D /! i)/
Review of the plans and
ST`9��
specifications covered by this
indicates
o�'JUE
ti = , , o
�'�
calculation compliance
with the Florida Energy Code.
is
Before construction completed
a
this building will be inspected for
compliance with Section 553.908
•con�y�
Florida Statutes.
BUILDING OFFICIAL:
DATE:
EnergyGauge® (Version: FLRCNA-200)
FORM 60OA-97
SUMMER CALCULATIONS
Residential Whole Building Performance Method A - Details
ADDRESS: , PORT ST LUCIE, FL, PERMIT #:
BASE
AS -BUILT
GLASS TYPES
X Conditioned X BSPM =
Points
Overhang
.18
Floor Area
Type/SC Ornt Len
Hgt Area X SPM
X SOF
= Points
.18 894.0
42.08
6771.1
Single, Clear E 1.0
5.5 27.0 59.31
0.96
1543.6
Single, Clear E 1.0
5.5 20.0 59.31
0.96
1143.4
Single, Clear S 1.0
4.3 7.0 44.66
0.88
274.5
As -Built Total:
54.0
2961.4
WALL TYPES
Area X BSPM = Points
Type
R-Value Area
X SPM
= Points
Adajcent
304.5 0.7
213.1
Concrete, Int Insul, Exterior
3.0 450.0
1.40
630.0
' Exterior
450.0 1.90
855.0
Concrete, Int Insul, Adjacent
3.0 304.5
0.70
213.1
Base Total:
754.5
1068.1
As -Built Total:
754.5
843.2
DOOR TYPES
Area X BSPM
= Points
Type
Area
X SPM
= Points
Adjacent
21.0 1.60
33.6
Adjacent Wood
21.0
2.40
50.4
Exterior
0.0 0.00
0.0
Base Total:
21.0
33.6
As -Built Total:
21.0
50.4
CEILING TYPES Area X BSPM
= Points
Type
R-Value Area
X SPM
= Points
U'er Attic
894.0 0.60
536.4
Under Attic
19.0 894.0
1.10
983.4
Bag Total:
894.0
636.4
As -Built Total:
894.0
983.4
1
FLLOR TYPES
Area X BSPM
= Points
Type
R-Value Area
X SPM
= Points
SI2i;}
98.0(p) -31.8
-3116.4
Slab -On -Grade Edge Insulation
0.0 98.0(p)
-31.90
-3126.2
RJ:r
0.0 0.00
0.0
Baotal:
-3116.4
As -Built Total:
-3126.2
' IPfRATION
Area XBSPM
=Points
Area X SPM
= Points
894.0 14.31
12793.1
894.0
14.31
12793.1
Slier Base Points:
18086.0
Summer As -Built Points:
14505.3
r:
dimmer
X System =
Cooling
Total X Cap X
Duct X System X
Credit
= Cooling
its
Multiplier
Points
Component Ratio
Multiplier Multiplier
Multiplier
Points
ti.
14605.3 1.000
0.930 0.341
1.000
4600.1
I 16.0
0.3577
6469.4
14505.3 1.00
0.930 0.341
1.000
4600.1
4+.
1
1
i�.
6eTM DCA Form 60OA-97
I
A I
FORM 60OA-97
WINTER CALCULATIONS
Residential Whole Building Performance Method A - Details
ADDRESS: , PORT ST LUCIE, FL, PERMIT #:
BASE
AS -BUILT
-GLASS TYPES
.18 X Conditioned X BWPM =
Points •
Overhang
Floor Area
Type/SC Ornt Len
Hgt Area X WPM X
WOF
= Points
.18 894.0
4.79
770.7
Single, Clear E 1.0
5.5 27.0 9.96
1.01
271.6
Single, Clear E 1.0
5.5 20.0 9.96
1.01
201.2
Single, Clear S 1.0
4.3 7.0 7.73
1.04
56.5
As -Built Total:
54.0
529.3
WALL TYPES
Area X
BWPM
= Points
Type
R-Value Area X
WPM
= Points
Adajcent
304.5
1.8
548.1
Concrete, Int Insul, Exterior
3.0 450.0
3.80
1710.0
Exterior
450.0
2.00
900.0
Concrete, Int Insul, Adjacent
3.0 304.5
2.30
700.3
Base Total:
754.5
1448.1
As -Built Total:
754.5
2410.4
DOOR TYPES
Area X
BWPM
= Points
Type
Area X
WPM
= Points
s Adjacent
21.0
4.00
84.0
Adjacent Wood
21.0
5.90
123.9
Exterior
0.0
0.00
0.0
Base Total:
21.0
84.0
As -Built Total:
21.0
123.9
CEILING TYPES Area X
BWPM
= Points
Type
R-Value Area X
WPM
= Points
Under Attic
894.0
0.60
536.4
Under Attic
19.0 894.0
1.00
894.0
Base Total:
894.0
536.4
As -Built Total:.
894.0
894.0
FLOOR TYPES
Area X
BWPM
= Points
Type
R-Value Area X
WPM
= Points
Slab
98.0(p)
-1.9
-186.2
Slab -On -Grade Edge Insulation
0.0 98.0(p)
2.50
245.0
Raised
0.0
0.00
0.0
Base Total:
-186.2
As -Built Total:
245.0
INFILTRATION
Area X
BWPM
= Points
Area X
WPM
= Points
894.0
-0.28
-250.3
894.0
-0.28
-250.3
Winter Base Points:
2402.7
Winter As -Built Points:
3952.3
Total Winter X
System
= Heating
Total X Cap X
Duct X System X
Credit
= Heating
Points
Multiplier
Points
Component Ratio
Multiplier Multiplier Multiplier
Points
3952.3 1.000
0.930 1.000
1.000
3675.6
2402.7
1.0730
2578.1
3952.3 1.00
0.930 1.000
1.000
3675.6
EnergyGaugeTm DCA Form 60OA-97
FORM 60OA-97
WATER___ HEATING & CODE_ COMPLIANCE STATUS
Residential Whole Building Performance Method A - Details
ADDRESS:, PORT ST LUCIE, FL, PERMIT #:
BASE AS -BUILT
WATER HEATING
Number of X Multiplier = Total Tank EF Number of X Tank X Multiplier X Credit = Total
Bedrooms Volume Bedrooms Ratio Multiplier
1 2564.00 2564.0 30.0 0.89 1 1.00 2535.19 1.00 2535.2
As -Built Total: 2535.2
CODE
COMPLIANCE
STATUS
BASE
AS -BUILT
Cooling + Heating +
Points Points
Hot Water
Points
= Total
Points
Cooling
Points
+ Heating + Hot Water = Total
Points Points Points
6469.4 2578.1
2564.0
11611.5
4600.1
3675.6 2535.2 10810.9
PASS
EnergyGaugeTm DCA Form 60OA-97
FORM 60OA-97
Code Compliance Checklist
Residential Whole Building Performance Method A - Details
ADDRESS:, PORT ST LUCIE, FL, PERMIT #:
6A-21 INFILTRATION REDUCTION COMPLIANCE CHECKLIST
COMPONENTS
SECTION
REQUIREMENTS FOR EACH PRACTICE
CHECK
Exterior Windows & Doors
606.1.ABC.1.1
Maximum:.3 cfm/s .ft. window area .5 cfm/s .ft. door area.
Exterior & Adjacent Walls
606.1.ABC.1.2.1
Caulk, gasket, weatherstrip or seal between: windows/doors & frames, surrounding wall;
foundation & wall sole or sill plate; joints between exterior wall panels at corners; utility
penetrations; between wall panels & top/bottom plates; between walls and floor.
EXCEPTION: Frame walls where a continuous infiltration barrier is installed that extends
from and is sealed to the foundation to the top plate.
Floors
606.1.ABC.1.2.2
Penetrations/openings >1/8" sealed unless backed by truss or joint members.
EXCEPTION: Frame floors where a continuous infiltration barrier is installed that is sealed
to the perimeter, penetrations and seams.
Ceilings
606.1.ABC.1.2.3
Between walls & ceilings; penetrations of ceiling plane of top floor; around shafts, chases,
soffits, chimneys, cabinets sealed to continuous air barrier; gaps in gyp board & top plate;
attic access. EXCEPTION: Frame ceilings where a continuous infiltration barrier is
installed that is sealed at the perimeter, at penetrations and seams.
Recessed Lighting Fixtures
606.1.ABC.1.2.4
Type IC rated with no penetrations, sealed; or Type IC or non -IC rated, installed inside a
sealed box with 1/2" clearance & 3" from insulation; or Type IC rated with < 2.0 cfm from
conditioned space, tested.
Multi -story Houses
606.1.ABC.1.2.5
Air barrier on perimeter of floor cavity between floors.
Additional Infiltration reqts
606.1.ABC.1.3
Exhaust fans vented to outdoors, dampers; combustion space heaters comply with NFPA,
have combustion air.
CA 99 fVrUC0 130CQf�010711/C RACACI IDCC 1—M- hn mn4 nr nvrnniinri rnv all racirinnePs I
COMPONENTS
SECTION
REQUIREMENTS
CHECK
Water Heaters
612.1
Comply with efficiency requirements in Table 6-12. Switch or clearly marked circuit
breaker electric or cutoff as must be provided. External or built-in heat trap required.
Swimming Pools & Spas
612.1
Spas & heated pools must have covers (except solar heated). Non-commercial pools
must have a pump timer. Gas spa & pool heaters must have a minimum thermal
efficiency of 78%.
Shower heads
612.1
Water flow must be restricted to no more than 2.5 gallons per minute at 80 PSIG.
Air Distribution Systems
610.1
All ducts, fittings, mechanical equipment and plenum chambers shall be mechanically
attached, sealed, insulated, and installed in accordance with the criteria of Section 610.
Ducts in unconditioned attics: R-6 min. insulation.
HVAC Controls
607.1
Separate readily accessible manual or automatic thermostat for each system.
Insulation
604.1, 602.1
Ceilings -Min. R-19. Common walls -Frame R-11 or CBS R-3 both sides.
Common ceiling & floors R-11.
EnergyGaugeTM DCA Form 60OA-97 EnergyGauge®/FlaRES'97 FLRCNA-200
a
A ,.
ENERGY PERFORMANCE LEVEL (EPL)
- DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE SCORE* = 84.1
The higher the score, the more efficient the home.
1. New construction or existing
.2. Single family or multi -family
3. Number of units, if multi -family
4. Number of Bedrooms
5. Is this a worst case?
6. Conditioned floor area (ft2)
7. Glass area & type
a. Clear - single pane
b. Clear - double pane
c. Tint/other SC/SHGC - single pane
d. Tintlother SC/SHGC - double pane
1. Floor types
a. Slab -On -Grade Edge Insulation
b. N/A
c. N/A
9. Wall types
a. Concrete, Int Insul, Exterior
b. Concrete, Int Insul, Adjacent
c. N/A
d. N/A
e. N/A
10. Ceiling types
a. Under Attic
b. N/A
c. N/A
11. Ducts
a. Sup: Con. Ret: Con. AH: Interior
b. N/A
RICH PROPERTIES,, PORT ST LUCIE, FL,
New _
12. Cooling systems
Multi -family _
a. Central Unit
1 _
1 _
b. N/A
Yes
_
8 4_ft:
c. N/A
54.0 ft2 _
13. Heating systems
0.0 ft2 _
a. Electric Strip
0.0 ft2 _
0.0 ft2
b. N/A
R=0.0, 98.0(p) ft _
c. N/A
14. Hot water systems
_
a. Electric Resistance
R=3.0, 450.0 ft2
R=3.0, 304.5 ft2 _
b. N/A
_
c. Conservation credits
(HR-Heat recovery, Solar
_
DHP-Dedicated heat pump)
R=19.0, 894.0 ft2 _
15. HVAC credits
_
(CF-Ceiling fan, CV -Cross ventilation,
HF-Whole house fan,
_
PT -Programmable Thermostat,
Sup. R=4.2, 30.0 ft _
RB-Attic radiant barrier,
MZ-C-Multizone cooling,
MZ-H-Multizone heating)
I certify that this home has complied with the Florida Energy Efficiency Code For Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant features.
Builder Signature:
Address of New Home:
Date:
City/FL Zip:
Cap: 21.5 kBtu/hr _
SEER: 10.00
Cap: 17.0 kBtu/hr _
COP: 1.00
Cap: 30.0 gallons _
EF: 0.89 _
*NOTE: The home's estimated energy performance score is only available through the FLARES computer program.
This is not a Building Energy Rating. If your score is 80 or greater (or 86 for a US EPADOE EnergyStardesignation),
your home may qualms for energy efficiency mortgage (EEM incentives ifyou obtain a Florida Energy Gauge Rating.
Contact the Energy Gauge Hotline at 4071638-1492 or see the Energy Gauge web site at www.fsec. ucf. edu for
information and a list of certified Raters. For information about Florida's Energy Efficiency Code For Building Construction,
contact the Department of Community Affairs at 8501487-1824.
EnergyGauge® (Version: FLRCNA-200)
RIGHT-J LOAD AND EQUIPMENT SUMMARY
Entire House
FES, INC. Job: 01089 4121199
34 N.W. 168TH. STREET, NORTH MIAMI BEACH, FL 33169 Phone: 305-653-0212 Fax: 305-65U232
Project• •
For: SAVANNA CLUB
PLAN Al TOP FL, FL
Phone: WC=e
Notes:
Design Information
Weather: Fort Lauderdale, FL, US
Winter. Design Conditions
Summer Design Conditions
Outside db
46
OF
Outside db
91
OF
Inside db
71.
OF
Inside db
75
OF
Design TD
25
OF
Design TD
16
OF
Daily range
M
Relative humidity
50
%
Moisture difference
60
gr/lb
Heating Summary
Sensible Cooling Equipment Load Sizing
Building heat loss
9451
Btuh
Structure
9934
Btuh
Ventilation air
0
cfm
Ventilation
880
Btuh
Ventilation air loss
0
Btuh
'Design temperature swing
3.0
OF
Design heat load
9451
Btuh
Use mfg. data
n
Rate/swing multiplier
0.96
Infiltration
Total sens. equip. load
10382
Btuh
Method
Simplified
Latent Cooling Equipment Load Sizing
Construction quality
Average
Fireplaces
0
Internal gains
460
Btuh
Ventilation
2032
Btuh
Heating
Cooling
Infiltration
2730
Btuh
Area (ft2)
(.694
893:�
Total latent equip. load
5223
Btuh
Volume (fF)
8046
8046
Air changes/hour
1.2
0.5
Total equipment load
15604
Btuh
Equiv. AVF (cfm)
161
67
Heating Equipment Summary
Cooling Equipment Summary
Make n/a
Make
- Trade
Trade
n/a
Efficiency
100.0 EFF
Efficiency
0.0 EER
•
Heating input
0
Btuh
Sensible cooling
0
Btuh
Heating output
0
Btuh
Latent cooling
0
Btuh
Heating temp rise
0
OF
Total cooling
0
Btuh
Actual heating fan
430
cfm
Actual cooling fan
430
cfm
Heating air flow factor
0.046
cfm/Btuh
Cooling air flow factor
0.043
cfm/Btuh
Space thermostat
Load sensible heat ratio
67
%
Printout certified by ACCA to meet all requirements of Manual J 7th Ed.
wng htsoft Right -Suite ResldentialTM 5.0.45 RSR23656 2001-Jul-05 09:11:50
H:ftightsott LOAD CALCS\SAVANNA CLUBIPLAN Al TOP.rsr Page 1
0 O
C_
0
CD
CD
Q.
^n
♦J
D
0
B
CD
CD
SD
O
3
(D
C
N
L
v
N•
m
a
O O W V O
Cn A W
N
•'.�
O
CO
CID
V
O
Cn
A W N -+
D�orry g
�Orrfn
� ^-vim- n
(�
CD
o i X Z
w w
O
osg
O w
=� Si
tD w
rt1
v Doi inc �
X�
m o rz
w w
E 0 fn Q
!n N f0
N .Oi. N N S
O y n . O O
N W
7
a
v O
N
E. N n
C N n
fR O N
D
m
7 O fp
ID
C.Z1 O y
O
0 0 �.. w 0
�
C'
N 3
w C-i/
D' r ^^ "
f0
C
O w y
7 7 CD
O O
O O
7 O
O
N
O w N
>>
O
O
S
y d o. Z
w pj 7
• cn ' N
7
N w
N N 7' —
O
(� O
N
N n
p to
p N
N n n
O
C
CD n
y 3=
w
II N a y
N
3
w
7
m
CD X O r
'o
w
C/,
a
n
N C-
+ CD +
y0.
�`(D n0fSw
�`CD nO CTw
"'CD n000
OVw
MCI)
�`CD nn Qw
"'tD nO tSw
p
11 D�
A C�
7'
m
ON
co
Low N A
0�
3+ f� �'�0��
f0
w
m m
C
j w d
vrm
Dv
O
W W NA
0z0co
00
Do
a ``,
�fCn ZS
WW
ozom
j CD
��11^
G
_n
=
Nla^
r
N
OOOOAO
CD 0000 �
000—N W
OAS
OOOO D7G)
OO o-+N w
!n
�
OOO Ofb W
00000 W
000011 LJO
00 (n
0000-�-�
00 tOA (J !n
=
p
NW
n
ko
00 o ON 0
00000 N
00� 0 �-+
O-'CO
000 Cn O,�N1
• '� '� • '� '�
OO�O--�-�
f0
00
OOOONO
00000�
000 mm w
000
000OD ObD
000CD co co
y D
S:
t S
�
� m
O CI
O
V
f00
O Cn (AJ1
W
C7t
N co V
w
O =
c �N
c
CA
o00000
000OOA
o 0o CnAO
OO
00000 Cn
000 OOA
OOOO) V
CD
i i
CD
co
♦ » s
CO CO
A
Z,
A4 Cn
N
S
0.
m A
0
0
0 0 0
A
0 0 0 0 o 0
0 0 0 0 0 COn
0 0 0 CA N O
O O N
0 0 0 0 0
W
C
♦ ♦ + w
'»�
» i i
92Z
ca
A coOCOO N O
OD
V
n
CA (a W OO
O AO o 0A 00
m
N
000000
tD
00000 Cn
t000
000 V Cn V
W
00 CO
CD
000 V 00
�io
x
o,
co
CA
Cn
N(A V
w
r
0 D
O O
�N
O
\
V
Cn
000000
co
000OOA
OCn CAn
OOO CnAO
00
000 CO OO,
OO o 00A
o 00(A V
00 Z
S X D
}$S$ }z
s
t0 O
w CD
(D co 0
C m
OL
0
O_A
WO
-�+000
A
000000
OOOOOCOn
0000 N o
OON
00000�
^W
• S$
W
x i i
i S S
to v
CD (O -+
10
co"
i i 2
Cp
co
V
co co
v
co
W A
V
A o 0 O A 0 0
N
0 0 0 0 0 0
0 0 0 0 0 M
0 0 0 V Cn
10000
0 0 0 0 0
w
d
•
S � i x � »
� i � i i '�
f0
52
C-
0
O
0
co
Co
A
N
m
tD
s 0
RIGHT-J CALCULATION PROCEDURES A, B, C, D
Entire House
FES, INC. Job: 01089 4121199
34 N.W.166TH. STREET, NORTH MIAMI BEACH, FL 33169 Phone: 305-653-0212 Fax: 305-653-0232
Procedure A - Winter Infiltration HTM Calculation*
1. Winter infiltration AVF
1.2 ach x 8046 ft3 x 0.0167 = 161 cfm
2. Winter infiltration load
1.1 x 161 cfm , x 25 OF Winter TD = 4434 Btuh
3. Winter infiltration HTM
4434 Btuh / 75 ft2 Total window = 59.1 Btuh/ftz
anddoor area
Procedure B - Summer Infiltration HTM Calculation
1. Summer infiltration AVF
0.5 ach x 8046 ft3 x 0.0167 = 67 cfm
2. Summer infiltration load
1.1 x67 cfm x 16 OF Summer TD = 1182 Btuh
3. Summer infiltration HTM
1182 Btuh / 75 ftz Total window = 15.8 Btuh/ft2
and door area
Procedure C - Latent Infiltration Gain
0.68 x 60 gr/lb moist.diff. x 67 cfm = 2730 Btuh
Procedure u - equipment bizing Loaas
1. Sensible sizing load
Sensible ventilation load
1.1 x 50 cfm vent. x 16 OF Summer TD =
880
Btuh
Sensible load for structure (Line 19) +
9934
Btuh
Sum of ventilation and structure loads =
10814
Btuh
Rating and temperature swing multiplier x
0.96
Equipment sizing load - sensible =
10382
Btuh
2. Latent sizing load
Latent ventilation load
0.68 x 50 cfm vent. x 60 gr/lb moist.diff. _
2032
Btuh
Internal loads = 230 Btuh x 2 people +
460
Btuh
Infiltration load from Procedure C +
2730
Btuh
Equipment sizing load - latent =
5223
Btuh
*Construction Quality is: a No. of Fireplaces is: 0
Bold/italic values have been manually overridden
Printout certified by ACCA to meet all requirements of Manual J 7th Ed.
ASF. wino htsoft Right -Suite Residerdialm S.0.45 RSR23656 2001-Jul-05 09:11:50
ACCK HAWrightsoft LOAD CALCSISAVANNA CLUBTLAN Al TOP.rsr Page 1
FORM 60OA-97
:FLORIDA ENERGY EFFICIENCY CODE__
FOR BUILDING CONSTRUCTION
Florida Department of Community Affairs
Residential Whole Building Performance Method A
Project Name: SAVANA CLUB APT UNIT A2TQ Builder:
Address: Permitting Office: PORT ST- LUG 14
City, State: PORT ST LUCIE, FL Permit Number:
Owner: RICH PROPERTIES Jurisdiction Number: (G 1z00
Climate Zone: Central
1. New construction or existing
New _
12. Cooling systems
- 2. Single family or multi -family
Multi -family _
a. Central Unit
Cap: 21.9 kBtu/hr _
3. Number of units, if multifamily
1 _
SEER: 10.00
4. Number of Bedrooms
1 _
b. N/A
_
5. Is this a worst case?
Yes
6. Conditioned floor area (ft2)
9ff
c. N/A
_
7. Glass area & type
_
_
a. Clear - single pane
54.0 ft2 _
13. Heating systems
b. Clear - double pane
0.0 ft2 _
a. Electric Strip
Cap: 17.0 kBtu/hr _
c. Tint/other SC/SHGC - single pane
0.0 ft2 _
COP: 1.00 _
d. Tint/other SC/SHGC - double pane
0.0 ft2
b. N/A
_
8. Floor types
a. Slab -On -Grade Edge Insulation
R=0.0, 46.0(p) ft _
c. N/A
_
b. N/A
c. N/A
14. Hot water systems
9. Wall types
_
a. Electric Resistance
Cap: 30.0 gallons _
a. Concrete, Int Insul, Exterior
R=3.0, 450.0 ft2 _
EF: 0.89
b. Concrete, hit Insul, Adjacent
R=3.0, 289.0 ft2 _
b. N/A
_
c. N/A
d. N/A
_
c. Conservation credits
_
e. N/A
(HR-Heat recovery, Solar
10. Ceiling types
_
DHP-Dedicated heat pump)
a. Under Attic
R=19.0, 914.0 ft2 _
15. HVAC credits
b. N/A
_
(CF-Ceiling fan, CV -Cross ventilation,
c. N/A
HF-Whole house fan,
11. Ducts
_
PT -Programmable Thermostat,
a. Sup: Con. Ret: Con. AH: Interior
Sup. R=4.2, 40.0 ft _
RB-Attic radiant barrier,
b. N/A
MZ-C-Multizone cooling,
MZ-H-Multizone heating)
Glass/Floor Area: 0.06 Total as -built points: 11164.00 Y PASS
Total base points: 12461.00
I hereby certify that the plans and specifications covered
by this calculation are in compliance with the Florida
Energy Code.
PREPARED BY:l6eei Ir-16•s♦ -- vc.
DATE:syP
I hereby certify that this building,,as designed, is in
compliance with the'Florida Ener X-
OWNERIAGENT:
DATE:
Review of the plans and
specifications covered by this
011�i'0IESIN.
calculation indicates compliance'
with the Florida Energy Code.
Before construction is completed
°�
a
this building will be inspected for
compliance with Section 553.908
�•ooD�S'�
Florida Statutes.
BUILDING OFFICIAL:
DATE:
EnergyGauge® (Version: FLRCNA-200)
I I
G
FORM 60OA-97
FLORIDA_ ENERGY EFFICIENCY CODE
FOR BUILDING CONSTRUCTION
Florida Department of Community Affairs
Residential Whole Building Performance Method A
Project Name: SAVANA CLUB APT UNIT A2� TOP Builder:
Address: Permitting Office:
City, State: PORT ST LUCIE, FL Permit Number:
Owner: RICH PROPERTIES Jurisdiction Number:
Climate Zone: Central
1. New construction or existing
New _
12. Cooling systems
- 2. Single family or multi -family
Multi -family _
a. Central Unit
3. Number of units, if multi -family
1 _
4. Number of Bedrooms
1 _
b. N/A
5. Is this a worst case?
Yes _
6. Conditioned floor area (ft2)
914 fie
c. N/A
7. Glass area & type
_
a. Clear - single pane
54.0 ft2 _
13. Heating systems
b. Clear - double pane
0.0 ft2 _
a. Electric Strip
c. Tint/other SC/SHGC - single pane
0.0 ft2 _
d. Tint/other SC/SHGC - double pane
0.0 ft2
b. N/A
8. Floor types
a. Slab -On -Grade Edge Insulation
R=0.0, 46.0(p) ft _
c. N/A
b. N/A
_
c. N/A
14. Hot water systems
9. Wall types
_
a. Electric Resistance
a. Concrete, Int Insul, Exterior
R=3.0, 450.0 ft2 _
b. Concrete, Int Insul, Adjacent
R=3.0, 289.0 ft2 _
b. N/A
c. N/A
_
d. N/A
_
c. Conservation credits
e. N/A
(HR-Heat recovery, Solar
10. Ceiling types
_
DHP-Dedicated heat pump)
a. Under Attic
R=19.0, 914.0 ft2 _
15. HVAC credits
b. N/A
_
(CF-Ceiling fan, CV -Cross ventilation,
c. N/A
HF-Whole house fan,
11. Ducts
_
PT -Programmable Thermostat,
a. Sup: Con. Ret: Con. AH: Interior
Sup. R=4.2, 40.0 ft _
RB-Attic radiant barrier,
b. N/A
MZ-C-Multizone cooling,
MZ-H-Multizone heating)
Y
Glass/Floor Area: 0.06 Total as -built points: 11164.00 PASS
Total base points: 12461.00
I hereby certify that the plans and specifications covered
by this calculation are in compliance with the Florida
Energy Code.
PREPARED BY:Nder-� -14' d IcE.s , Tiyc
DATE: ? a
I hereby certify that this building, as designed, is in
compliance with the Florida Ener o
OWNERIAGENT:
DATE: /D
Cap: 21.9 kBtu/hr _
SEER: 10.00
Cap: 17.0 kBtu/hr _
COP: 1.00
Cap: 30.0 gallons _
EF: 0.89
Review of the plans and AUE ST`9T�
specifications covered by this
0
calculation indicates compliance
�,,;'''� • _
with the Florida Energy Code.
Before construction is completed
a
this building will be inspected for
compliance with Section 553.908
�•�on�5't
Florida Statutes.
wE
BUILDING OFFICIAL:
DATE:
EnergyGauge® (Version: FLRCNA-200)
R
FORM 60OA-97
SUMMER CALCULATIONS
Residential Whole Building Performance Method A - Details
ADDRESS: , PORT ST LUCIE, FL, PERMIT #:
BASE
AS -BUILT
-GLASS TYPES
.18 X Conditioned X BSPM =
Points
Overhang
Floor Area
Type/SC Ornt Len
Hgt Area X SPM
X SOF
= Points
.18 914.0
42.08
6922.6
Single, Clear E 2.0
5.0 27.0 59.31
0.81
1290.2
Single, Clear E 2.0
5.0 20.0 59.31
0.81
955.7
Single, Clear S 2.0
3.0 7.0 44.66
0.63
197.1
As -Built Total:
64.0
2443.1
WALL TYPES
Area X BSPM
= Points
Type
R-Value Area
X SPM
= Points
Adajcent
289.0 0.7
202.3
Concrete, Int Insul, Exterior
3.0 450.0
1.40
630.0
Exterior
450.0 1.90
855.0
Concrete, Int Insul, Adjacent
3.0 289.0
0.70
202.3
Base Total:
739.0
1057.3
As -Built Total:
739.0
832.3
DOOR TYPES
Area X BSPM
= Points
Type
Area
X SPM
= Points
Adjacent
21.0 1.60
33.6
Adjacent Wood
21.0
2.40
50.4
Exterior
0.0 0.00
0.0
Base Total:
21.0
33.6
As -Built Total:
21.0
50.4
CEILING TYPES Area X BSPM
= Points
Type
R-Value Area
X SPM
= Points
Under Attic
914.0 0.60
548.4
Under Attic
19.0 914.0
1.10
1005.4
Base Total:
914.0
548.4
As -Built Total:
914.0
1005.4
FLOOR TYPES
Area X BSPM
= Points
Type
R-Value Area
X SPM
= Points
Slab
46.0(p) -31.8
-1462.8
Slab -On -Grade Edge Insulation
0.0 46.0(p)
-31.90
-1467.4
Raised
0.0 0.00
0.0
Base Total:
-1462.8
As -Built Total:
-1467.4
INFILTRATION
Area X BSPM
= Points
Area X SPM
= Points
914.0 14.31
13079.3
914.0
14.31
13079.3
Summer Base Points:
20178.4
Summer As -Built Points:
15943.1
Total Summer
X System =
Cooling
Total X Cap X
Duct X System X
Credit
= Cooling
Points
Multiplier
Points
Component Ratio
Multiplier Multiplier
Multiplier
Points
15943.1 1.000
1
0.930 0.341
1.000
5056.0
20178.4
0.3577
7217.8
15943.1 1.00
0.930 0.341
1.000
5066.0
EnergyGaugeTm DCA Form 60OA-97
r <
FORM 60OA-97
WINTER_ CALCULATIONS
-� Residential Whole Building Performance Method A - Details
ADDRESS: , PORT ST LUCIE, FL,
PERMIT #:
BASE
AS -BUILT
GLASS TYPES
.18 X Conditioned
X BWPM =
Points
Overhang
Floor Area
Type/SC Ornt Len
Hgt Area X WPM X
WOF
= Points
18 914.0
4.79
788.0
Single, Clear E 2.0
5.0 27.0 9.96
1.04
280.3
Single, Clear E 2.0
5.0 20.0 9.96
1.04
207.6
Single, Clear S 2.0
3.0 7.0 7.73
1.51
81.8
As -Built Total:
64.0
669.7
WALL TYPES
Area X BWPM
= Points
Type
R-Value Area X
WPM
= Points
Adajcent
289.0 1.8
520.2
Concrete, Int Insul, Exterior
3.0 450.0
3.80
1710.0
Exterior
450.0 2.00
900.0
Concrete, Int Insul, Adjacent
3.0 289.0
2.30
664.7
Base Total:
739.0
1420.2
As -Built Total:
739.0
2374.7
DOOR TYPES
Area X BWPM
= Points
Type
Area X
WPM
= Points
Adjacent
21.0 4.00
84.0
Adjacent Wood
21.0
5.90
123.9
Exterior
0.0 0.00
0.0
Base Total:
21.0
84.0
As -Built Total:
21.0
123.9
CEILING TYPES Area X BWPM
= Points
Type
R-Value Area X
WPM
= Points
Under Attic
914.0 0.60
548.4
Under Attic
19.0 914.0
1.00
914.0
Base Total:
914.0
648.4
As -Built Total:
914.0
914.0
FLOOR TYPES
Area X BWPM
= Points
Type
R-Value Area X
WPM
= Points
Slab
46.0(p) -1.9
-87.4
Slab -On -Grade Edge Insulation
0.0 46.0(p)
2.50
115.0
Raised
0.0 0.00
0.01
Base Total:
-87.4
As -Built Total:
115.0
INFILTRATION
Area X BWPM
= Points
Area X
WPM
= Points
914.0 -0.28
-255.9
914.0
-0.28
-255.9
Winter Base Points:
2497.3
Winter As -Built Points:
3841.4
Total Winter X
System = Heating
Total X Cap X
Duct X System X
Credit =
Heating
Points
Multiplier
Points
Component Ratio
Multiplier Multiplier Multiplier
Points
3841.4 1.000
0.930 1.000
1.000
3572.5
2497.3
1.0730
2679.6
3841.4 1.00
0.930 1.000
1.000
3572.5
EnergyGaugeTm DCA Form 60OA-97
x
FORM 60OA-97
WATER HEATING & CODE COMPLIANCE STATUS.
Residential Whole Building Performance Method A - Details
ADDRESS: , PORT ST LUCIE, FL, PERMIT #:
BASE AS -BUILT
WATER HEATING
Number of X Multiplier = Total Tank EF Number of X Tank X Multiplier X Credit = Total
Bedrooms Volume Bedrooms Ratio Multiplier
1 2564.00 2564.0 30.0 0.89 1 1.00 2535.19 1.00 2535.2
As -Built Total: 2535.2
CODE
COMPLIANCE
STATUS
BASE
AS -BUILT
Cooling + Heating +
Points Points
Hot Water
Points
= Total
Points
Cooling
Points
+ Heating + Hot Water = Total
Points Points Points
7217.8 2679.6
2564.0
12461.4
5056.0
3572.5 2535.2 11163.7
PASS
EnergyGaugeTm DCA Form 60OA-97
r I
FORM 60OA-97
Code Compliance Checklist
Residential Whole Building Performance Method A - Details
ADDRESS: , PORT ST LUCIE, FL, PERMIT #:
6A-21 INFILTRATION REDUCTION COMPLIANCE CHECKLIST
COMPONENTS
SECTION
REQUIREMENTS FOR EACH PRACTICE
CHECK
Exterior Windows & Doors
606.1.ABC.1.1
Maximum:.3 cfm/s .ft. window area; .5 cfm/s .ft. door area.
Exterior & Adjacent Walls
606.1.ABC.1.2.1
Caulk, gasket, weatherstrip or seal between: windows/doors & frames, surrounding wall;
foundation & wall sole or sill plate; joints between exterior wall panels at corners; utility
penetrations; between wall panels & top/bottom plates; between walls and floor.
EXCEPTION: Frame walls where a continuous infiltration barrier is installed that extends
from and is sealed to the foundation to the top plate.
Floors
606.1.ABC.1.2.2
Penetrations/openings >1/8" sealed unless backed by truss or joint members.
EXCEPTION: Frame floors where a continuous infiltration barrier is installed that is sealed
to the perimeter, penetrations and seams.
Ceilings
606.1.ABC.1.2.3
Between walls & ceilings; penetrations of ceiling plane of top floor; around shafts, chases,
soffits, chimneys, cabinets sealed to continuous air barrier; gaps in gyp board & top plate;
attic access. EXCEPTION: Frame ceilings where a continuous infiltration barrier is
installed that is sealed at the perimeter, at penetrations and seams.
Recessed Lighting Fixtures
606.1.ABC.1.2.4
Type IC rated with no penetrations, sealed; or Type IC or non -IC rated, installed inside a
sealed box with 1/2" clearance & 3" from insulation; or Type IC rated with < 2.0 cfm from
conditioned space, tested.
Multi -story Houses
606.1.ABC.1.2.5
Air barrier on pqrimeter of floor cavity between floors.
Additional Infiltration reqts
606.1.ABC.1.3
Exhaust fans vented to outdoors, dampers; combustion space heaters comply with NFPA,
have combustion air.
CA 12H f%'MICO D0CC!`01DT1\/C RIICAQI IQCQ ha Maf nr AW-00fi!Oei hV All rAQitIP_flCP--R_1
COMPONENTS
SECTION
REQUIREMENTS
CHECK
Water Heaters
612.1
Comply with efficiency requirements in Table 6-12. Switch or clearly marked circuit
breaker electric or cutoff as must be provided. External or built-in heat trap required.
Swimming Pools & Spas
612.1
Spas & heated pools must have covers (except solar heated). Non-commercial pools
must have a pump timer. Gas spa & pool heaters must have a minimum thermal
efficient of 78%.
Shower heads
612.1
Water flow must be restricted to no more than 2.5 gallons per minute at 80 PSIG.
Air Distribution Systems
610.1
All ducts, fittings, mechanical equipment and plenum chambers shall be mechanically
attached, sealed, insulated, and installed in accordance with the criteria of Section 610.
Ducts in unconditioned attics: R-6 min. insulation.
HVAC Controls
607.1
Separate readily accessible manual or automatic thermostat for each system.
Insulation
604.1, 602.1
Ceilings -Min. R-19. Common walls -Frame R-11 or CBS R-3 both sides.
Common ceiling & floors R-11.
EnergyGaugeTm DCA Form 60OA-97 EnergyGauge®/FlaRES'97 FLRCNA-200
4
ENERGY PERFORMANCE LEVEL (EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE
SCORE* = 84.0
The higher the score, the more efficient the home.
RICH PROPERTIES,, PORT ST LUCIE, FL,
1. New construction or existing
New -
12. Cooling systems
' 2. Single family or multi -family
Multi -family -
a. Central Unit
Cap: 21.9 kBtu/hr -
3. Number of units, if multi -family
1 -
SEER: 1.0.00 -
4. Number of Bedrooms
1 -
b. N/A
-
5. Is this a worst case?
Yes -
-
6. Conditioned floor area (W)
9I47ft2
c. N/A
-
7. Glass area & type
-
-
a. Clear - single pane
54.0 ft2 _
13. Heating systems
b. Clear - double pane
0.0 ft2 -
a. Electric Strip
Cap: 17.0 kBtu/hr -
c. Tint/other SC/SHGC - single pane
0.0 ft2 -
COP: 1.00 -
d. Tintlother SC/SHGC - double pane
0.0 ft2
b. N/A
-
8. Floor types
-
-
a. Slab -On -Grade Edge Insulation
R=0.0, 46.0(p) ft -
c. N/A
-
b. N/A
-
-
c. N/A
14. Hot water systems
9. Wall types
-
a. Electric Resistance
Cap: 30.0 gallons -
a. Concrete, Int Insul, Exterior
R=3.0, 450.0 ft2 -
EF: 0.89 -
b. Concrete, Int Insul, Adjacent
R=3.0, 289.0 ft2 -
b. N/A
-
c. N/A
-
-
d. N/A
-
c. Conservation credits
-
e. N/A
(HR-Heat recovery, Solar
10. Ceiling types
-
DHP-Dedicated heat pump)
a. Under Attic
R=19.0, 914.0 ft2 -
15. HVAC credits
-
b. N/A
-
(CF-Ceiling fan, CV -Cross ventilation,
c. N/A
HF-Whole house fan,
11. Ducts
-
PT -Programmable Thermostat,
a. Sup: Con. Ret: Con. AH: Interior
Sup. R=4.2, 40.0 ft -
RB-Attic radiant barrier,
b. N/A
MZ-C-Multizone cooling,
MZ-H-Multizone heating)
f certify that this home has complied with the Florida Energy Efficiency Code For Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant features.
Builder Signature:
Date:
JUE sT47
F
Address of New Home: City/FL Zip: c'0 WU
l
%. *NOTE: The home's estimated energy performance score is only available through the FLARES computer program.
This is not a Building Energy Rating. I our score is 80 or greater or 86 or a US EPADOE Ener StarTmdesi ation
your home may qualify for energy eff ciency mortgage (EEM incentives if you obtain a Florida Energy Gauge Rating.
Contact the Energy Gauge Hotline at 4071638-1492'or see the Energy Gauge web site at www.fsec. ucf. edu for
information and a list of certified Raters. For information about Florida's Energy Efficiency Code For Building Construction,
contact the Department of Community Affairs at 8501487-1824.
EnergyGauge® (Version: FLRCNA-200)
0
RIGHT-J LOAD AND EQUIPMENT SUMMARY
0Entire House
FES, INC. Job: SAVANA CLUB UNIT
A2-TOP 4121/99
34 N.W. 168TH. STREET, NORTH MIAMI BEACH, FL 33169 Phone: 305-653-0212 Fax: 305-653-0232
Project • •
For: SAVANNA-CL-UV
UNIT�A2-TOP, F
Phone: WG—W__--.1
Notes: SAVANA CLUB UNIT A2-TOP
Design
Information
Weather:
West Palm Beach, FL, US
Winter Design Conditions
Summer Design Conditions
Outside db 47 OF
Outside db
90 OF
Inside db 71 OF
Inside db
75 OF
Design TD 24 OF
Design TD
15 OF
L
Daily range
Relative humidity
50 %
Moisture difference
61 gr/lb
Heating Summary
Building heat loss 12568 Btuh
Ventilation air 0 cfm
Ventilation air loss 0 Btuh
Design heat load 12568 Btuh
Infiltration
Method
Construction quality
Fireplaces
Area (ftz)
Volume (ft')
Air changes/hour
Equiv. AVF (cfm)
Simplified
Average
0
Heating
Cooling
[914--914
8226
8226
1.0
0.5
137
69
Heating Equipment Summary
Make n/a
Trade
n/a
Efficiency
Heating Input
Heating output
Heating temp rise
Actual heating fan
Heating air flow factor
Space thermostat
100.0 EFF
0 Btuh
0 Btuh
0 OF
559 cfm
0.044 cfm/Btuh
Sensible Cooling Equipment Load Sizing
Structure
12903
Btuh
Ventilation
825
Btuh
Design temperature swing
3.0
OF
Use mfg. data
n
Rate/swing multiplier
0.95
Total sens. equip. load
13041
Btuh
Latent Cooling Equipment Load Sizing
Internal gains
460
Btuh
Ventilation
2088
Btuh
Infiltration
2868
Btuh
Total latent equip. load
5416
Btuh
Total equipment load 18458 Btuh
Cooling Equipment Summary
Make
Trade
Efficiency
Sensible cooling
Latent cooling
Total cooling
Actual cooling fan
Cooling air flow factor
Load sensible heat ratio
0.0 EER
0
Btuh
0
Btuh
0
Btuh
559
cfm
0.043
cfm/Btuh
72 %
Printout certified by ACCA to meet all requirements of Manual J 7th Ed.
wr�g htsoft Right -Suite Residential"' 5.0.58 RSR23656 2001-Oct-09 17:12:03
ACC% H:\Wrightsoft LOAD CALCS\SAVANNA CLUB\PLAN A2 TOP.rsr Page 1
Ll
I
RIGHT-J SHORT FORM
Entire House
WR FES, INC. Job: SAVANA CLUB UNIT
A2-TOP 4121199
34 N.W. 168TH. STREET, NORTH MIAMI BEACH, FL 33169 Phone: 305-653-0212 Fax: 305-653-0232
Project• •
For: SAVANNA CLUB
UNITP_,_FLJ
Phone: WC=W
Design Information
Htg Clg Infiltration
Outside db (OF) 47 90 Method Simplified
Inside db (OF) 71 75 Construction quality Average
Design TD (OF) 24 15 Fireplaces 0
Daily range - L
Inside humidity (%) - 50
Moisture difference (gr/lb) - 61
HEATING EQUIPMENT
Make n/a
Trade
n/a
Efficiency
100.0 EFF
Heating input
0
Btuh
Heating output
0
Btuh
Heating temperature rise
0
OF
Actual heating fan
559
cfm
Heating air flow factor
0.044
cfm/Btuh
Space thermostat
COOLING EQUIPMENT
Make
Trade
Efficiency
0.0 EER
Sensible cooling .
0
Btuh
Latent cooling
0
Btuh
Total cooling
0
Btuh
Actual cooling fan
559
cfm
Cooling air flow factor
0.043
cfm/Btuh
Load sensible heat ratio 72 %
ROOM NAME
Area
Htg load
Clg load
Htg AVF
Clg AVF
(ft2)
(Btuh)
(Btuh)
(cfm)
(cfm)
UNIT-1 ALT.
914—
12568
12903
559
559
Entire House d
914
12568
12903
559
559
Ventilation air
0
825
Equip. @ 0.95 RSM
13041
'
Latent cooling
5416
-Al ^
I r%4A
42Ar.R
I rira
I AR -CI
Printout certified by ACCA to meet all requirements of Manual J 7th Ed.
,$_: wrightsoft Right -Suite Residential TM 5.0.58 RSR23656 2001-Oct-09 17:12:04
C)M H:1Wrightsoft LOAD CALCSISAVANNA CLUBIPLAN A2 TOP.rsr Page 1
Ott
I^
N W
rJ
vN
DD
0
Ito
D�
0
c;
CD CD
CL
D �
Z myy
9
Op
V O
� m
N
N
W
m
M
O
r
CD
r.
C
n
0
CD
CD
T
O c0 0 V 0
CT A W
N
O
co
0
V
O¢f
CT
A W N+
D-IGrrfA M
O
-i�rrfA
O»
o o u; � ZT
n
0 d x z
0
o m
m ag
920
eft
X4
m 6 6-
C ccn N Q
.�N N f0
N 'N 5E
61 V. N
4
O N Ll 7. O_
� y
3�(@i
O
a —'O .r
C. V1 O
m
c�
O to 7
w n
D7 V! 7
CN d
�Z. N O N
C N
N
Om
7 0 cp 3
cp 3 (D
7'
O O
A �O (D Lb.
O
OOram^CD O
Ci
N
vUM .O.
y
(D
770
O'
d
7 O
Cfl dS
7 O
cG d
O N
O.
NnO
y G_ O!.0
C• (/1 �. N
N N _
7
- 00
N n
00
p f/i
p
CQ
-n
ny �
a H)0
3
� n
n
m
0rr
m�
(A.103
3�
g�.
± ��
�. �j D "0
A c. 9
N n �S
� � m
� CD d 0 CS D1
"� CD O. 0 Cr SO
-w cp d 0 (J 0)
0 CS 21
2 V1 fA Z Z
-w cp d 0 C7 0f
�. cp n 0 [7 N
�'E'
g �P.
°�a
agN
a
c>zcNim
av
za
�z:0
.z°y
. ^/mom
\�@
N
+ +
N N
r +
TI
co
0000 A cD
00000+
O OO+N W
00—
0000OI CJI
O OO+N W
fG
'O
O
10,
CGOOOA
OGGCO tJ
OOCO.D•IV in
OA
OO COA N in
=
OC
O O
O O O O N O
O O O O O N
O O++ N N
+ +
O N O
m N
O O O N O V
S S S S S S
O O++ N N
O
0 0
0 0 0 O 0 0
C C 0 0 0 G1
O O W+ C N
O V A
O O O O O O
C O W O N
D
O
O.}SMOOOOOO
S
O
c0
N A
A
j
c(��
OD V
O
0 7
C
OOO OOA
OOO o 0
0 0
OO�}0 co 0 N.1S
a O OOA
OO OSS++ V
(p
N
w
f0 nN
CD m
OD
i S S i
N
'
N
fD
0
N
Cfl
0000 OD
V
A
0000 O
00000
O 00VIS"
w
00
000OOW
c
Er}$
}S
7S
N N+
CT K) CON0
i i
+
N
N
N O
W+_c0
W
W W
W cD
i S S
Ov
d.
N O 0 0 0
coo O O O W O O
W
W
N
COMM O O
0
O O O O O W
cD
0 0 0 W O+
0 0 0
0 0 0 0 0 0
�CD
i
c
0 Z
0 0
O
V
O
c+
m C" ccn
N
w
C�
OD V
D)
0
+N
\
0
O OOOOO
00000 A
OOOO A O
O O+
OOO c0O CA
0000 Oi+.
O OO++ V
O
+
S S S
cG
N x D
C
0 S S
cn cNil
G
A
j' 0
N
W
to
O.
C
t0D
0000 co
V
pp
OOOOA O
00000 W
000 V V NN
O O N
0000 OAC�
C
.T
ss
*S
S i
*S SS *S
i i i
g.�.
N N+cp
O00
N
0
+�
W W
W W
C071O
CO c) OO$ W O O
W
W
O O O O O O
O O O O O W
O OO W O
00m
OOO CA O CD
�j
�
gg SS
ss �j5 Sq j
tog
Sz?z
i i
i i S
i i
192
m
m
>
-
^^
N =w Y+
?
Z CD
r
nCD
0
O
go
0
T
O
9
cn
8
mT
N
1 „
x
—I
G
FORM 60OA-97
FLORIDA ENERGY EFFICIENCY CODE
FOR BUILDING CONSTRUCTION
Florida Department of Community Affairs
Residential Whole Building Performance Method A./.d
Project Name: SAVANNA CLUB PLAW 9B t Builder:
Address: Permitting Office: PORT %7*- 40414-7
City, State: Permit Number:
Owner: Jurisdiction Number: 66AZ00
Climate Zone: Central
1. New construction or existing
New _
12. Cooling systems
. 2. Single family or multi -family
Multi -family _
a. Central Unit
3. Number of units, if multi -family
1 _
4. Number of Bedrooms
1 _
b. N/A
5. Is this a worst case?
Yes _
6. Conditioned floor area (ft2)
T013 ftz
c. N/A
7. Glass area & type
_
a. Clear - single pane
96.0 ftz _
13. Heating systems
• b. Clear - double pane
0.0 ftz _
a. Electric Strip
c. Tint/other SC/SHGC - single pane
0.0 ft2 _
d. Tint/other SC/SHGC - double pane
0.0 ft2
b. N/A
• 8. Floor types
_
a. Slab -On -Grade Edge Insulation
R=0.0, 84.0(p) ft _
c. N/A
b. N/A
_
c. N/A
14. Hot water systems
9. Wall types
_
a. Electric Resistance
a. Concrete, Int Insul, Exterior
R=5.0, 336.0 ft2 _
b. Concrete, Int Insul, Adjacent
R=5.0, 309.0 ft2 _
b. N/A
c. N/A
_
d. N/A
_
c. Conservation credits
e. N/A
(HR Heat recovery, Solar
10. Ceiling types
_
DHP-Dedicated heat pump)
a. N/A
_
15. HVAC credits
b. N/A
_
(CF-Ceiling fan, CV -Cross ventilation,
c. N/A
BF -Whole house fan,
11. Ducts
_
PT -Programmable Thermostat,
a. Sup: Con. Ret: Con. AH: Interior
Sup. R=4.2, 30.0 ft _
RB-Attic radiant barrier,
b. N/A
MZ-C-Multizone cooling,
MZ-H-Multizone heating)
Glass/Floor Area: 0.09 Total as -built points: 10315.00 ' PASS
Total base points: 11725.00
hereby certify that the plans and specifications covered
by this calculation are in compliance with the Florida
Energy Code.
PREPARED BY:AIdr �09 _'�, S,vc
DATE:
I hereby certify that this building, as designed, is in
compliance with the Florida Ene � y de.
OWNER/AGENT:
DATE:
Cap: 24.3 kBtu/hr
SEER 10.00 _
Cap: 17.0 kBtu/hr
COP: 1.00
Cap: 40.0 gallons _
EF: 0.89
Review of the plans and
zip sT
aT�0
specifications covered by this
yob =
calculation indicates compliance
irp .,•,...., 1.
with the Florida Energy Code.
Before construction is completed
a
this building will be inspected for
compliance with Section 553.908
icon���
Florida Statutes.
wa
BUILDING OFFICIAL:
DATE:
EnergyGauge® (Version: FLRCNA-200)
r
FORM 60OA-97
FLORIDA ENERGY EFFICIENCY CODE
FOR BUILDING CONSTRUCTION
Florida Department of Community Affairs
Residential Whole Building Performance Method A
Project Name: SAVANNA CLUB PLAN B1 BOT Builder:
Address: Permitting Office:
City, State: Permit Number:
Owner: Jurisdiction Number:
Climate Zone: Central
1. New construction or existing
New _
12. Cooling systems
2. Single family or multi -family
Multi -family _
a. Central Unit
3. Number of units, if multi -family
1
4. Number of Bedrooms
1 _
b. N/A
5. Is this a worst case?
Yes
6. Conditioned floor area (ft2)
1'Olf 3-ft? c.
N/A
7. Glass area & type
a. Clear - single pane
96.0 ft2 _
13. Heating systems
- b. Clear - double pane
0.0 ft2 _
a. Electric Strip
c. Tint/other SC/SHGC - single pane
0.0 ft2 _
d. Tint/other SC/SHGC - double pane
0.0 ft2
b. N/A
8. Floor types
a. Slab -On -Grade Edge Insulation
R=0.0, 84.0(p) ft _
c. N/A
b. N/A
_
c. N/A
14. Hot water systems
9. Wall types
_
a. Electric Resistance
a. Concrete, Int Insul, Exterior
R=5.0, 336.0 ft2 _
b. Concrete, Int Insul, Adjacent
R=5.0, 309.0 ft2 _
b. N/A
c. N/A
_
d. N/A
_
c. Conservation credits
e. N/A
(HR-Heat recovery, Solar
10. Ceiling types
_
DHP-Dedicated heat pump)
a. N/A
_
15. HVAC credits
b. N/A
_
(CF-Ceiling fan, CV -Cross ventilation,
c. N/A
BF -Whole house fan,
11. Ducts
_
PT -Programmable Thermostat,
a. Sup: Con. Ret: Con. AH: Interior
Sup. R=4.2, 30.0 ft _
RB-Attic radiant barrier,
b. N/A
MZ-C-Multizone cooling,
MZ-H-Multizone heating)
Glass/Floor Area: 0.09 Total as -built points: 10315.00 ' PASS
Total base points: 11725.00
I hereby certify that the plans and specifications covered
by this calculation are in compliance with the Florida
Energy Code.
PREPARED BY:A16-re� IcF:S
DATE: �Z�wi
I hereby certify that this building, as desi ned, is in
compliance with the Florida En 7
y C e.
OWNER/AGENT:
DATE:
Cap: 24.3 kBtu/hr _
SEER: 10.00
Cap: 17.0 kBtu/hr
COP: 1.00
Cap: 40.0 gallons
EF: 0.89
Review of the plans and
ZKE ST
AT�O
specifications covered by this
tio4 -
calculation indicates compliance�'�
with the Florida Energy Code.
Before is completed
construction
a
this building will be inspected for
compliance with Section 553.908
•COD�y'S
Florida Statutes.
wE
BUILDING OFFICIAL:
DATE:
EnergyGauge® (Version: FLRCNA-200)
FORM 60OA-97
SUMMER CALCULATIONS
Residential Whole Building Performance Method A - Details
ADDRESS: , , , PERMIT #:
.
BASE
AS -BUILT
- GLASS TYPES
.18 X Conditioned X BSPM =
Points
Overhang
Floor Area
Type/SC Ornt Len
Hgt Area X SPM
X SOF
= Points
.18 1013.0 42.08
7672.4
Single, Clear E 1.0
5.5 20.0 59.31
0.96
1141.9
Single, Clear E 5.0
7.7 56.0 59.31
0.65
2164.6
Single, Clear E 1.0
5.5 20.0 59.31
0.96
1143.4
As -Built Total:
96.0
4449.9
WALL TYPES
Area X BSPM
= Points
Type
R-Value Area
X SPM
= Points
Adajcent
309.0 0.7
216.3
Concrete, Int Insul, Exterior
5.0 336.0
1.00
336.0
Exterior
336.0 1.90
638.4
Concrete, Int Insul, Adjacent
5.0 309.0
0.60
185.4
Base Total:
645.0
854.7
As -Built Total:
645.0
521.4
DOOR TYPES
Area X BSPM
= Points
Type
Area
X SPM
= Points
Adjacent
21.0 1.60
33.6
Adjacent Wood
21.0
2.40
50.4
Exterior
0.0 0.00
0.0
Base Total:
21.0
33.6
As -Built Total:
21.0
50.4
CEILING TYPES Area X BSPM
= Points
Type
R-Value Area
X SPM
= Points
Under Attic
0.0 0.00
0.0
Base Total:
0.0
0.0
As -Built Total:
0.0
0.0
FLOOR TYPES
Area X BSPM
= Points
Type
R-Value Area
X SPM
= Points
Slab
84.0(p) -31.8
-2671.2
Slab -On -Grade Edge Insulation
0.0 84.0(p)
-31.90
-2679.6
Raised
0.0 0.00
0.0
Base Total:
-2671.2
As -Built Total:
-2679.6
INFILTRATION
Area X BSPM
= Points
Area X SPM
= Points
1013.0 14.31
14496.0
1013.0
14.31
14496.0
Summer Base Points:
20385.5
Summer As -Built Points:
16838.1
Total Summer
X System =
Cooling
Total X Cap X
Duct X System X
Credit
= Cooling
Points
Multiplier
Points
Component Ratio
Multiplier Multiplier
Multiplier
Points
16838.1 1.000
1
'0.930 0.341
1.000
5339.9
20385.5
03577
7291.9
16838.1 1.00
0.930 0.341
1.000
5339.9
EnergyGaugeTM DCA Form 60OA-97
FORM 60OA-97
WINTER CALCULATIONS
Residential Whole Building Performance Method A - Details
ADDRESS: , , , PERMIT #:
BASE
AS -BUILT
- GLASS TYPES
.18 X Conditioned X BWPM =
Points •
Overhang
Floor Area
Type/SC Ornt Len
Hgt Area X WPM X
WOF
= Points
18 1013.0
4.79
873.3
Single, Clear E 1.0
5.5 20.0 9.96
1.01
201.2
Single, Clear E 5.0
7.7 56.0 9.96
1.09
609.7
Single, Clear E 1.0
5.5 20.0 9.96
1.01
201.2
As -Built Total:
96.0
1012.1
-WALL TYPES
Area X
BWPM
= Points
Type
R-Value Area X
WPM
= Points
Adajcent
309.0
1.8
556.2
Concrete, Int Insul, Exterior
5.0 336.0
2.90
974.4
Exterior
336.0
2.00
672.0
Concrete, Int Insul, Adjacent
5.0 309.0
1.90
587.1
Base Total:
645.0
1228.2
As -Built Total:
645.0
1561.5
DOOR TYPES
Area X
BWPM
= Points
Type
Area X
WPM
= Points
Adjacent
21.0
4.00
84.0
Adjacent Wood
21.0
5.90
123.9
Exterior
0.0
0.00
0.0
Base Total:
21.0
84.0
As -Built Total:
21.0
123.9
CEILING TYPES Area X
BWPM
= Points
Type
R-Value Area X
WPM
= Points
Under Attic
0.0
0.00
0.0
Base Total:
0.0
0.0
As -Built Total:
0.0
0.0
FLOOR TYPES
Area X
BWPM
= Points
Type
R-Value Area X
WPM
= Points
Slab
84.0(p)
-1.9
-159.6
Slab -On -Grade Edge Insulation
0.0 84.0(p)
2.50
210.0
Raised
0.0
0.00
0.0
Base Total:
-159.6
As -Built Total:
210.0
INFILTRATION
Area X
BWPM
= Points
Area X
WPM
= Points
1013.0
-0.28
-283.6
1013.0
-0.28
-283.6
Winter Base Points:
1742.3
Winter As -Built Points:
2623.9
Total Winter X
System
= Heating
Total X Cap X
Duct X System X
Credit =
Heating
Points
Multiplier
Points
Component Ratio
Multiplier Multiplier Multiplier
Points
2623.9 1.000
0.930 1.000
1.000
2440.2
1742.3
1.0730
1869.5
2623.9 1.00
0.930 1.000
1.000
2440.2
EnergyGaugeTm DCA Form 60OA-97
r
FORM 60OA-97
WATER HEATING & CODE COMPLIANCE STATUS
Residential Whole Building Performance Method A - Details
ADDRESS: , , , PERMIT #:
BASE AS -BUILT
-WATER HEATING
Number of X Multiplier = Total • Tank EF Number of X Tank X Multiplier X Credit = Total
Bedrooms Volume Bedrooms Ratio Multiplier
1 2564.00 2564.0 40.0 0.89 1 1.00 2535.19 1.00 2535.2
As -Built Total: 2535.2
CODE
COMPLIANCE
STATUS
BASE
AS -BUILT
Cooling + Heating +
Points Points
Hot Water
Points
= Total
Points
Cooling
Points
+ Heating + Hot Water = Total
Points Points Points
7291.9 1869.6
2564.0
11725.4
5339.9
2440.2 2635.2 10315.3
PASS
:..IC en.--et-
EnergyGauge'rm DCA Form 60OA-97
e
FORM 60OA-97
Code Compliance Checklist
Residential Whole Building Performance Method A - Details
ADDRESS: , , , PERMIT #:
6A-21 INFILTRATION REDUCTION COMPLIANCE CHECKLIST
COMPONENTS
SECTION
REQUIREMENTS FOR EACH PRACTICE
CHECK
Exterior Windows & Doors
606.1.ABC.1.1
Maximum:.3 cfm/s .ft. window area; .5 cfm/s .ft. door area.
Exterior & Adjacent Walls
606.1.ABC.1.2.1
Caulk, gasket, weatherstrip or seal between: windows/doors & frames, surrounding wall;
foundation & wall sole or sill plate; joints between exterior wall panels at comers; utility
penetrations; between wall panels & top/bottom plates; between walls and floor.
EXCEPTION: Frame walls where a continuous infiltration barrier is installed that extends
from and is sealed to the foundation to the top plate.
Floors
606.1.ABC.1.2.2
Penetrations/openings >1/8" sealed unless backed by truss or joint members.
EXCEPTION: Frame floors where a continuous infiltration barrier is installed that is sealed
to the perimeter, penetrations and seams.
Ceilings
606.1.ABC.1.2.3
Between walls & ceilings; penetrations of ceiling plane of top floor; around shafts, chases,
soffits, chimneys, cabinets sealed to continuous air barrier; gaps in gyp board & top plate;
attic access. EXCEPTION: Frame ceilings where a continuous infiltration barrier is
installed that is sealed at the perimeter, at penetrations and seams.
Recessed Lighting Fixtures
606.1.ABC.1.2.4
Type IC rated with no penetrations, sealed; or Type IC or non -IC rated, installed inside a
sealed box with 1/2" clearance & 3" from insulation; or Type IC rated with < 2.0 cfm from
conditioned space, tested.
Multi -story Houses
606.1.ABC.1.2.5
Air barrier on perime r of floor cavity between floors.
Additional Infiltration reqts
606.1.ABC.1.3
Exhaust fans vented to outdoors, dampers; combustion space heaters comply with NFPA,
have combustion air.
&A_ff9 rVirUED DDCQC`DIDTIVC MCAQI IDCQ /mne4 hn maf nr nvrnnr11nr1 her m11 racirllancac I
COMPONENTS
SECTION
REQUIREMENTS
CHECK
Water Heaters
612.1
Comply with efficiency requirements in Table 6-12. Switch or clearly marked circuit
breaker electric or cutoff as must be provided. External or built-in heat trap required.
Swimming Pools & Spas
612.1
Spas & heated pools must have covers (except solar heated). Non-commercial pools
must have a pump timer. Gas spa & pool heaters must have a minimum thermal
efficient of 78%.
Shower heads
612.1
Water flow must be restricted to no more than 2.5 gallons per minute at 80 PSIG.
Air Distribution Systems
610.1
All ducts, fittings, mechanical equipment and plenum chambers shall be mechanically
attached, sealed, insulated, and installed in accordance with the criteria of Section 610.
Ducts in unconditioned attics: R-6 min. insulation.
HVAC Controls
607.1
Separate readily accessible manual or automatic thermostat for each system.
Insulation
604.1, 602.1
Ceilings -Min. R-19. Common walls -Frame R-11 or CBS R-3 both sides.
Common ceiling & floors R-11.
EnergyGaugeTm DCA Form 60OA-97 EnergyGauge®/FlaRES'97 FLRCNA-200
v
0
ENERGY PERFORMANCE LEVEL (EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE SCORE* = 84.3
The higher the score, the more efficient the home.
1.
New construction or existing
New
_ 12. Cooling systems
- 2.
Single family or multi -family
Multi -family
_ a. Central Unit
Cap: 24.3 kBtu/hr _
3.
Number of units, if multi -family
1
_
SEER: 10.00
4.
Number of Bedrooms
1
_ b. N/A
5.
Is this a worst case?
Yes
6.
Conditioned floor area (ft2)
1013 ftz
c. N/A
7.
Glass area & type
a. Clear - single pane
96.0 ft2
_ 13. Heating systems
'
b. Clear - double pane
0.0 ft2
_ a. Electric Strip
Cap: 17.0 kBtu/hr _
c. Tint/other SC/SHGC - single pane
0.0 ft2
_
COP: 1.00
d. Tint/other SC/SHGC - double pane
0.0 ft2
b. N/A
_
8.
Floor types
a. Slab -On -Grade Edge Insulation
R=0.0, 84.0(p) ft
_ c. N/A
b. N/A
_
c. N/A
14. Hot water systems
9.
Wall types
_ a. Electric Resistance
Cap: 40.0 gallons
a. Concrete, hit Insul, Exterior
R=5.0, 336.0 ft2
_
EF: 0.89 _
b. Concrete, Int Insul, Adjacent
R=5.0, 309.0 ft2
_ b. N/A
c. N/A
_
d. N/A
_ c. Conservation credits
e. N/A
(HR-Heat recovery, Solar
10. Ceiling types
_ DHP-Dedicated heat pump)
a. N/A
_ 15. HVAC credits
_
b. N/A
_ (CF-Ceiling fan, CV -Cross ventilation,
c. N/A
BF -Whole house fan,
11. Ducts
_ PT -Programmable Thermostat,
a. Sup: Con. Ret: Con. AH: Interior
Sup. R=4.2, 30.0 ft
_ RB-Attic radiant barrier,
b. N/A
MZ-C-Multizone cooling,
MZ-H-Multizone heating)
certify that this home has complied with the Florida Energy Efficiency Code For Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
-based on installed Code compliant features.
Builder Signature:
Address of New Home:
Date:
City/FL Zip:
p. 04THE sr9�
rnn
COD w8
*NOTE: The home's estimated energy performance score is only available through the FLARES computer program.
This is not a Building Energy Rating. If your score is 80 or greater (or 86 for a US EPADOE EnergyStar designation),
your home may qualms for energy efficiency mortgage (EEM incentives ifyou obtain a Florida Energy Gauge Rating.
Contact the Energy Gauge Hotline at 4071638-1492 or see the Energy Gauge web site at www.fsec. ucf edu for
information and a list of certified Raters. For information about Florida's Energy Efficiency Code For Building Construction,
' contact the Department of Community Affairs at 8501487-1824.
EnergyGauge® (Version: FLRCNA-200)
RIGHT-J LOAD AND EQUIPMENT SUMMARY
Entire House
FES, INC. Job: 01089 4121199
34 N.W. 168TH. STREET, NORTH MIAMI BEACH, FL 33169 Phone: 305-653-0212 Fax: 305-653-0232
Project• •
For: SAVANNA CLUB APT
;PLAN-61—FL�
Phone: WC=e
Notes:
Design Information
Weather: Fort Lauderdale, FL, US
Winter Design Conditions Summer Design Conditions
Outside db 46 OF Outside db 91 OF
Inside db 71 OF Inside db 75 OF
Design TD 25 OF Design TD 16 OF
Daily range M
Relative humidity 50 %
Moisture difference 60 gr/lb
Heating Summary Sensible Cooling Equipment Load Sizing
Building heat loss
10292
Btuh
Structure
11127
Btuh
Ventilation air
0
cfm
Ventilation
1760
Btuh
Ventilation air loss
0
Btuh
Design temperature swing
3.0
OF
Design heat load
10292
Btuh
Use mfg. data
n
Rate/swing multiplier
0.96
Infiltration
Total sens. equip. load
12372
Btuh
Method
Simplified
Latent Cooling Equipment Load
Sizing
Construction quality
Average
Fireplaces
0
Internal gains
690
Btuh
Ventilation
4064
Btuh
Heating
Cooling
Infiltration
3094
Btuh
Area (ftZ)
013�
Total latent equip. load
7848
Btuh
Volume (ft3)
9117-91`17
Air changes/hour
1.0
0.5
Total equipment load
20220
Btuh
Equiv. AVF (cfm)
152
76
Heating Equipment Summary
Cooling Equipment Summary
Make n/a
Make
• Trade
Trade
n/a
Efficiency
100.0 EFF
Efficiency
0.0 EER
Heating input
0
Btuh
Sensible cooling
0
Btuh
Heating output
0
Btuh
Latent cooling
0
Btuh
Heating temp rise
0
OF
Total cooling
0
Btuh
Actual heating fan
482
cfm
Actual cooling fan
482
cfm
Heating air flow factor
0.047
cfm/Btuh
Cooling air flow factor
0.043
cfm/Btuh
Space thermostat
Load sensible heat ratio
62
%
Printout certified by ACCA to meet all requirements of Manual J 7th Ed.
wrrghtsoft Right -Suite Residential 5.0.45 RSR23656 2001-Jul-05 09:14:39
i1CCi\ H:\Wrightsoft LOAD CALCS199049\U2BOT.rsr Page 1
7
O
rat
CD
a;
CD
a
^n
`!
0
3
CD
CD
N
O
W
L
zF
m
a
O (O W V O
U) A W
N
O
c0
co
J
C)
cn
A W N+
D—Iprrtn S
-iOrrm
g
�o u;v^ n
0
a F X Z
O
0 g
=��i
w m inc O
m
�c4
.0s.
Z77
(G
(mii vmi C
N .O. N N
O
S'
O G 7. O O
f-i!v y y 3 (D O
7
in O
'� N
!�
to d
7 O
r N d
7 O
m O U)
O w y co
'0
O m
C O f0 3 2
to r1^ m
C w mo 7•
oNNmD)
w
Q�m y
N
770.
O
t�0 `d
00
77 p,
Nd
Co
y 5 O�.Z
(D 2C=�� N
HN�Np
j
f��
Nd
O
N(n
�N
.Z1T
�mOD
d� N=
11 � w ww
3
d
d
m
w 0El �-
7 _.
+
J
�m dO cw
'""(D dOQw
'""N d0 0, 0)
O O'w
2mm ZZ
—M d0 cw
"'m 0. C) O'w
O 11 D�
o_
A �•�
nN d m
d
t�tNu
DD
O
+
0z0ccoo
Do
w+
WW
+
wwN•P
OZ0co
Zn
0�
+
(G i'V O
3 w v
U3
+
w
o o o
a Ery Zi
o d
7
d
m
�r2 2
`.
N
O O O O A O
0 0 0 0 0+
O O O+ N W
+
O A+
N N
O O O O m
O O O+ N W
C)
=
^^m
N lcv
+
N
O
0
co
OOOOCD W
OOOCO W
OOcoA W C)
OOC)
0000++
C O(DA W
p
+
OO
000 000 N+
00+0++
W N
C, OC,
_n
O0
(T
000OON
C) W OD
OC)O
C)00coOCD
OOC)C)C)CD
*
y
m
m
O
k
O
(O
fW.1 (A+)
w
0•
CDO
+W
O
�
J
OD
O OOOO A
O O OOO O
(WA
O OO co O 0)0
N
0+
J N
O OOO OO
000000
O$TO OO O7SsN
d' N
(O n
CD r-
N
• M
O O
N
O
W
N
N000
co
00000
000 OO
A
O
O
co
^�
C
ss
¢$qq zz
ggSS
(T
w
(ov
d
N V000 V 00
0
000000
000000
o t
OOOOO(T
00 (O
�
000 W O (T
_
3D
S O » k
+
O W
fp
W (Aj
w
O Y
O [�C
0\ +(,p
\
V
OOOOOA
000000
000(O O 0)
N
00+
J N
000000
000000
OOOOON
�' O Z
� X �
w M + M
k
»: i '� i
N,
}$
C
. .
N
v
A j
N
A
V
O
a
0
coA
N
co OOON
V
1 00000
000000
000 (TOO
00 N
00000co
^W
C
O W
,'S
CA
U93
co V000J00
O
000000
000000
O (WO
00000(T
W
00(o
co
m (.)
w
• S Z»
i i
i i•
(O
�y
�
♦ »» �•}�
• S♦ »
ryy » 1ST
111111
HIM
CD
YI
O
20
N
m
m
q
RIGHT-J CALCULATION PROCEDURES A, B, C, D
Entire House
FES, INC. Job:01089 4/21199
34 N.W. 168TH. STREET, NORTH MIAMI BEACH, FL 33169 Phone: 305-653-0212 Fax: 305-653-0232
Procedure A - Winter Infiltration HTM Calculation*
1. Winter infiltration AVF
1.0 ach x 9117 ft3 x 0.0167 = 152 cfm
2. Winter infiltration load
1.1 x 152 cfm x 25 OF Winter TD = 4187 Btuh
3. Winter infiltration HTM
4187 Btuh / 117 ft2 Total window = 35.8 Btuh/ft2
and door area
Procedure B - Summer Infiltration HTM Calculation
1. Summer infiltration AVF
0.5 ach x 9117 ft3 x 0.0167 = 76 cfm
2. Summer infiltration load
1.1 x76 cfm x 16 OF SummerTD = 1340 Btuh
3. Summer infiltration HTM
1340 Btuh / 117 ft2 Total window = 11.5 Btuh/ft2
and door area
Procedure C - Latent Infiltration Gain
0.68 x 60 gr/lb moist.diff. x 76 cfm = 3094 Btuh
rroceaurU LJ - r-gUIFJIIItl11L 011-1119 L-Uaua
1. Sensible sizing load
Sensible ventilation load
1.1 x 100 cfm vent. x 16 OF Summer TD =
1760
Btuh
Sensible load for structure (Line 19) +
11127
Btuh
Sum of ventilation and structure loads =
12887
Btuh
Rating and temperature swing multiplier x
0.96
Equipment sizing load - sensible =
12372
Btuh
2. Latent sizing load
Latent ventilation load
0.68 x 100 cfm - vent. x 60 gr/lb moist.diff. _
4064
Btuh
Internal loads = 230 Btuh x 3 people +
690
Btuh
Infiltration load from Procedure C +
3094
Btuh
Equipment sizing load - latent =
7848
Btuh
*Construction Quality is: a
No. of Fireplaces is: 0
Bold/italic values have been manually overridden
Printout certified by ACCA to meet all requirements of Manual J 7th Ed.
�• wrjghtsoft Right -Suite Residential*^+ 5.0.45 RSR23656 2001-Jul-05 09:14:39
ACCK H:\Wdghtsoft LOAD CALCS\99049\U2BOT.rsr Page 1
a
a
FORM 60OA-97
FLORIDA ENERGY EFFICIENCY CODE
FOR BUILDING CONSTRUCTION
Florida Department of Community Affairs
Residential Whole Building Performance Method A
Project Name: SAVANNA CLUB PLAN' 2 B0_ Builder:
Address: Permitting Office: PORT sT MIC-1 '
City, State: PORT ST LUCIE, FL Permit Number:
Owner: RICH PROPERTIES Jurisdiction Number: G610,66
Climate Zone: Central
1.
New construction or existing
New
2.
Single family or multi -family
Multi -family _
3.
Number of units, if multi -family
1
4.
Number of Bedrooms
1 _
5.
Is this a worst case?
Yes
6.
Conditioned floor area (ft2)
C1084aft2-
7.
Glass area & type
_
a. Clear - single pane
67.0 ft2
-
b. Clear - double pane
0.0 ft2 _
c. Tint/other SC/SHGC - single pane
0.0 ft2 _
d. Tint/other SC/SHGC - double pane
0.0 ft2
8.
Floor types
_
a. Slab -On -Grade Edge Insulation
R=0.0, 78.0(p) ft
b. N/A
c. N/A
9.
Wall types
a. Frame, Wood, Exterior
R=3.0, 110.0 ft2
b. Concrete, Int Insul, Adjacent
R=3.0, 309.0 ft2 _
c. N/A
d. N/A
e. N/A
10. Ceiling types
a. N/A
b. N/A
_
c. N/A
11. Ducts
a. Sup: Con. Ret: Con. AH: Interior
Sup. R=4.2, 40.0 ft
b. N/A
12. Cooling systems
a. Central Unit
Cap: 26.0 kBtu/hr _
SEER:10.00 _
b. N/A
c. N/A
13. Heating systems
a. Electric Strip
Cap: 17.0 kBtu/hr _
COP: 1.00 _
b. N/A
c. N/A
14. Hot water systems
a. Electric Resistance
Cap: 40.0 gallons
EF: 0.89 _
b. N/A
c. Conservation credits _
(HR-Heat recovery, Solar
DHP-Dedicated heat pump)
15. HVAC credits
(CF-Ceiling fan, CV -Cross ventilation,
HF-Whole house fan,
PT -Programmable Thermostat,
RB-Attic radiant barrier,
MZ-C-Multizone cooling,
MZ-H-Multizone heating)
Glass/Floor Area: 0.06 Total as -built points: 9935.40 y PASS
Total base points: 11767.00
I hereby certify that the plans and specifications covered
by this calculation are in compliance with the Florida
Energy Code.
PREPARED BY:A/dre-l- 5-Wai PE.S ZLM
DATE:
I hereby certify that this building, -as desi 'ed, is in
compliance with the Florida En C e.
OWNER/AGENT:
DATE:
Review of the plans and
STATF
specifications covered by this
o4Tx�
calculation indicates compliance
with the Florida Energy Code.
Before construction is completed
this building will be inspected for
compliance with Section 553.908
11•�oD�5't
Florida Statutes.
wE
BUILDING OFFICIAL:
DATE:
EnergyGauge® (Version: FLRCNA-200)
0
I
FORM 60OA-97
FLORIDA ENERGY EFFICIENCY CODE
FOR BUILDING CONSTRUCTION
Florida Department of Community Affairs
Residential Whole Building Performance Method A
Project Name: SAVANNA CLUB PLAN B2 BOT Builder:
Address: Permitting Office:
City, State: PORT ST LUCIE, FL Permit Number:
Owner: RICH PROPERTIES Jurisdiction Number:
Climate Zone: Central
.1. New construction or existing
New _
12. Cooling systems
2. Single family or multi -family
Multi -family _
a. Central Unit
3. Number of units, if multi -family
1 _
4. Number of Bedrooms
1 _
b. N/A
5. Is this a worst case?
Yes _
6. Conditioned floor area (W)
1D84'ft2
c. N/A
7. Glass area & type
_
a. Clear - single pane
67.0 ft2 _
13. Heating systems
b. Clear - double pane
0.0 ft2 _
a. Electric Strip
c. Tint/other SC/SHGC - single pane
0.0 ft2 _
d. Tint/other SC/SHGC - double pane
0.0 ft2
b. N/A
8. Floor types
_
a. Slab -On -Grade Edge Insulation
R=0.0, 78.0(p) ft _
c. N/A
b. N/A
_
c. N/A
14. Hot water systems
9. Wall types
_
a. Electric Resistance
a. Frame, Wood, Exterior
R=3.0, 110.0 ft2 _
b. Concrete, Int Insul, Adjacent
R=3.0, 309.0 ft2 _
b. N/A
c. N/A
_
d. N/A
_
c. Conservation credits
e. N/A
(HR-Heat recovery, Solar
10. Ceiling types
_
DHP-Dedicated heat pump)
a. N/A
_
15. HVAC credits
b. N/A
_
(CF-Ceiling fan, CV -Cross ventilation,
c. N/A
HF-Whole house fan,
11. Ducts
_
PT -Programmable Thermostat,
a. Sup: Con. Ret: Con. AH: Interior
Sup. R=4.2, 40.0 ft _
RB-Attic radiant barrier,
b. N/A
MZ-C-Multizone cooling,
MZ-H-Multizone heating)
Glass/Floor Area: 0.06 Total as -built points: 9935.40 ~ PASS
Total base points: 11767.00
I hereby certify that the plans and specifications covered
by this calculation are in compliance with the Florida
Energy Code.
PREPARED BYAIA-d 4-d ic
DATE:
I hereby certify that this building, as designed, is in
compliance with the Florida Ener o
OWNER/AGENT:
DATE:
Cap: 26.0 kBtu/hr
SEER: 10.00
Cap: 17.0 kBtu/hr _
COP: 1.00
Cap: 40,0 gallons
EF: 0.89
Review of the plans and
AU ST9T
specifications covered by this
° _ _
'.VA.
calculation indicates compliance
�,,,°''� " _
with the Florida Energy Code.
Before construction is completed
this building will be inspected for
�.
compliance with Section 553.908
icon
Florida Statutes.
we'``�y�
BUILDING OFFICIAL:
DATE:
EnergyGauge® (Version: FLRCNA-200)
FORM 60OA-97
SUMMER CALCULATIONS
Residential Whole Building Performance Method A - Details
I ADDRESS:, PORT ST LUCIE, FL, PERMIT #: I
BASE
AS -BUILT
"GLASS TYPES
.18 X Conditioned X BSPM =
Points
Overhang
Floor Area
Type/SC Ornt Len
Hgt Area X SPM
X SOF
= Points
18 1084.0
42.08
8210.2
Single, Clear E 1.0
5.5 20.0 59.31
0.96
1141.9
Single, Clear E 1.0
5.5 27.0 59.31
0.96
1543.6
Single, Clear E 1.0
5.5 20.0 59.31
0.96
1143.4
As -Built Total:
67.0
3828.8
1NALL TYPES
Area X BSPM
= Points
Type
R-Value Area
X SPM
= Points
.Adajcent
309.0 0.7
216.3
Frame, Wood, Exterior
3.0 110.0
4.64
510.7
Exterior
110.0 1.90
209.0
Concrete, Int Insul, Adjacent
3.0 309.0
0.70
216.3
Base Total:
419.0
425.3
As -Built Total:
419.0
727.0
DOOR TYPES
Area X BSPM
= Points
Type
Area
X SPM
= Points
Adjacent
21.0 1.60
33.6
Adjacent Wood
21.0
2.40
50.4
Exterior
0.0 0.00
0.0
Base Total:
21.0
33.6
As -Built Total:
21.0
50.4
CEILING TYPES
Area X BSPM
= Points
Type
R-Value Area
X SPM
= Points
Under Attic
0.0 0.00
0.0
Base Total:
0.0
0.0
As -Built Total:
0.0
0.0
FLOOR TYPES
Area X BSPM
= Points
Type
R-Value Area
X SPM
= Points
Slab
78.0(p) -31.8
-2480.4
Slab -On -Grade Edge Insulation
0.0 78.0(p)
-31.90
-2488.2
Raised
0.0 0.00
0.0
Base Total:
-2480.4
As -Built Total:
-2488.2
INFILTRATION
Area X BSPM
= Points
Area X SPM
= Points
1084.0 14.31
15512.0
1084.0
14.31
15512.0
Summer Base Points:
21700.7
Summer As -Built Points:
17630.1
Total Summer
X System =
Cooling
Total X Cap X
Duct X System X
Credit
= Cooling
Points
Multiplier
Points
Component Ratio
Multiplier Multiplier
Multiplier
Points
17630.1 1.000
0.930 0.341
1.000
5591.0
21700.7
0.3577
7762.3
17630.1 1.00
0.930 0.341
1.000
5591.0
EnergyGaugeTm DCA Form 60OA-97
FORM 60OA-97
WINTER CALCULATIONS
Residential Whole Building Performance Method A - Details
ADDRESS:, PORT ST LUCIE, FL, PERMIT #:
BASE
AS -BUILT
GLASS TYPES
.18 X Conditioned X BWPM =
Points,
Overhang
Floor Area
Type/SC Ornt Len
Hgt Area X WPM X WOF
= Points
.18 1084.0
4.79
934.5
Single, Clear E 1.0
5.5 20.0 9.96
1.01
201.2
Single, Clear E 1.0
5.5 27.0 9.96
1.01
271.6
Single, Clear E 1.0
5.5 20.0 9.96
1.01
201.2
As -Built Total:
67.0
674.0
'WALL TYPES
Area X
BWPM
= Points
Type
R-Value Area X
WPM
= Points
Adajcent
309.0
1.8
556.2
Frame, Wood, Exterior
3.0 110.0
4.96
545.3
Exterior
110.0
2.00
220.0
Concrete, Int Insul, Adjacent
3.0 309.0
2.30
710.7
Base Total:
419.0
776.2
As -Built Total:
419.0
1256.0
DOOR TYPES
Area X
BWPM
= Points
Type
Area X
WPM
= Points
Adjacent
21.0
4.00
84.0
Adjacent Wood
21.0
5.90
123.9
Exterior
0.0
0.00
0.0
Base Total:
21.0
84.0
As -Built Total:
21.0
123.9
CEILING TYPES Area X
BWPM
= Points
Type
R-Value Area X
WPM
= Points
Under Attic
0.0
0.00
0.0
Base Total:
0.0
0.0
As -Built Total:
0.0
0.0
FLOOR TYPES
Area X
BWPM
= Points
Type
R-Value Area X
WPM
= Points
Slab
78.0(p)
-1.9
-148.2
Slab -On -Grade Edge Insulation
0.0 78.0(p)
2.50
195.0
Raised
0.0
0.00
0.0
Base Total:
-148.2
As -Built Total:
195.0
INFILTRATION
Area X
BWPM
= Points
Area X
WPM
= Points
1084.0
-0.28
-303.5
1084.0
-0.28
-303.5
Winter Base Points:
1343.0
Winter As -Built Points:
1946.4
Total Winter X
System
= Heating
Total X Cap X
Duct X System X
Credit =
Heating
Points
Multiplier
Points
Component Ratio
Multiplier Multiplier Multiplier
Points
1945.4 1.000
0.930 1.000
1.000
1809.2
1343.0
1.0730
1441.1
1945.4 1.00
0.930 1.000
1.000
1809.2
EnergyGaugeTm DCA Form 60OA-97
FORM 60OA-97
WATER HEATING & CODE COMPLIANCE STATUS
Residential Whole Building Performance Method A - Details
ADDRESS:, PORT ST LUCIE, FL, PERMIT #:
BASE AS -BUILT
'WATER HEATING
Number of X Multiplier = Total Tank EF Number of X Tank X Multiplier X Credit = Total
Bedrooms Volume Bedrooms Ratio Multiplier
1 2564.00 2564.0 40.0 0.89 1 1.00 2535.19 1.00 2535.2
As -Built Total: 2535.2
CODE
COMPLIANCE
STATUS
BASE
AS -BUILT
Cooling + Heating +
Points Points
Hot Water
Points
= Total
Points
Cooling
Points
+ Heating + Hot Water = Total
Points Points Points
7762.3 1441.1
2564.0
11767.4
5591.0
1809.2 2535.2 9935.4
PASS
EnergyGaugeTm DCA Form 60OA-97
FORM 60OA-97
Code Compliance Checklist
Residential Whole Building Performance Method A - Details
ADDRESS: , PORT ST LUCIE, FL, PERMIT #:
6A-21 INFILTRATION REDUCTION COMPLIANCE CHECKLIST
COMPONENTS
SECTION
REQUIREMENTS FOR EACH PRACTICE
CHECK
Exterior Windows & Doors
606.1.ABC.1.1
Maximum:.3 cfm/s .ft. window area; .5 cfm/s .ft. door area.
Exterior & Adjacent Walls
606.1.ABC.1.2.1
Caulk, gasket, weatherstrip or seal between: windows/doors & frames, surrounding wall;
foundation & wall sole or sill plate; joints between exterior wall panels at corners; utility
penetrations; between wall panels & top/bottom plates; between walls and floor.
EXCEPTION: Frame walls where a continuous infiltration barrier is installed that extends
from and is sealed to the foundation to the top plate.
Floors
606.1.ABC.1.2.2
Penetrations/openings >118" sealed unless backed by truss or joint members.
EXCEPTION: Frame.floors where a continuous infiltration barrier is installed that is sealed
to the pedmeter, penetrations and seams.
Ceilings
606.1 ABC.1.2.3
Between walls & ceilings; penetrations of ceiling plane of top floor; around shafts, chases,
soffits, chimneys, cabinets sealed to continuous air barrier; gaps in gyp board & top plate;
attic access. EXCEPTION: Frame ceilings where a continuous infiltration barrier is
installed that is sealed at the perimeter, at penetrations and seams.
Recessed Lighting Fixtures
606.1.ABC.1.2.4
Type IC rated with no penetrations, sealed; or Type IC or non -IC rated, installed inside a
sealed box with 1/2" clearance & 3" from insulation; or Type IC rated with < 2.0 cfm from
conditioned space, tested.
Multi -story Houses
606.1.ABC.1.2.5
Air barrier on perimeter of floor cavity between floors.
Additional Infiltration reqts
606.1.ABC.1.3
Exhaust fans vented to outdoors, dampers; combustion space heaters comply with NFPA,
have combustion air.
RA-99 r1T149=0 DR1=Sr'D1DTIV1= MGACI IRFC /mnc4 ho mo4 nr ovraarlarl by all racirlancac 1
COMPONENTS
SECTION
REQUIREMENTS
CHECK
Water Heaters
612.1
Comply with efficiency requirements in Table 6-12. Switch or clearly marked circuit
breaker electric or cutoff as must be provided. External or built-in heat trap required.
Swimming Pools & Spas
612.1
Spas & heated pools must have covers (except solar heated). Non-commercial pools
must have a pump timer. Gas spa & pool heaters must have a minimum thermal
efficient of 78%.
Shower heads
612.1
Water flow must be restricted to no more than 2.5 gallons per minute at 80 PSIG.
Air Distribution Systems
610.1
All ducts, fittings, mechanical equipment and plenum chambers shall be mechanically
attached, sealed, insulated, and installed in accordance with the criteria of Section 610.
Ducts in unconditioned attics: R-6 min. insulation.
HVAC Controls
607.1
Seperate readily accessible manual or automatic thermostat for each system.
Insulation
604.1, 602.1
Ceilings -Min. R-19. Common walls -Frame R-11 or CBS R-3 both sides.
Common ceiling & floors R-11. Y
EnergyGaugeTm DCA Form 60OA-97 EnergyGauge®/FlaRES'97 FLRCNA-200
ENERGY PERFORMANCE LEVEL (EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE SCORE* = 85.2
The higher the score, the more efficient the home.
1.
New construction or existing
2.
Single family or multi -family
3.
Number of units, if multi -family
4.
Number of Bedrooms
5.
Is this a worst case?
6.
Conditioned floor area (ft2)
7.
Glass area & type
a. Clear - single pane
b. Clear - double pane
c. Tint/other SC/SHGC - single pane
•
d. Tintlother SC/SHGC - double pane
8.
Floor types
a. Slab -On -Grade Edge Insulation
b. N/A
c. N/A
9.
Wall types
a. Frame, Wood, Exterior
b. Concrete, Int Insul, Adjacent
c. N/A
d. N/A
e. N/A
10. Ceiling types
a. N/A
b. N/A
c. N/A
11. Ducts
a. Sup: Con. Ret: Con. AH: Interior
b. N/A
RICH PROPERTIES,, PORT ST LUCIE, FL,
New _
12. Cooling systems
Multi -family _
a. Central Unit
1
1 _
b. N/A
Yes
_
c. N/A
67.0 ft2 _
13. Heating systems
0.0 ft2 _
a. Electric Strip
0.0 ft2 _
0.0 ft2
b. N/A
R=0.0, 78.0(p) ft _
c. N/A
14. Hot water systems
_
a. Electric Resistance
R=3.0, 110.0 ft2
R=3.0, 309.0 ft2 _
b. N/A
_
c. Conservation credits
(ER -Heat recovery, Solar
_
DHP-Dedicated heat pump)
_
15. HVAC credits
_
(CF-Ceiling fan, CV -Cross ventilation,
HF-Whole house fan,
_
PT -Programmable Thermostat,
Sup. R=4.2, 40.0 ft _
RB-Attic radiant barrier,
MZ-C-Multizone cooling,
MZ-H-Multizone heating)
I•certify that this home has complied with the Florida Energy Efficiency Code For Building .
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant features.
Builder Signature:
Address of New Home:
Date:
City/FL Zip:
Cap: 26.0 kBtu/hr
SEER: 10.00
Cap: 17.0 kBtu/hr _
COP: 1.00
Cap: 40.0 gallons
EF: 0.89
*NOTE. The home's estimated energyperformance score is only available through the FLARES computer program.
This is not a Building Energy Rating. If your score is 80 or greater (or 86 for a US EPADOE EnergyStar'designation),
your home may qualms for energy efficiency mortgage (EEA1) incentives ifyou obtain a Florida Energy Gauge Rating.
Contact the Energy Gauge Hotline at 4071638-1492 or see the Energy Gauge web site at www.fsec. ucf edu for
information and a list of certified Raters. For information about Florida's Energy Efficiency Code For Building Construction,
contact the Department of Community Affairs at 8501487-1824.
- . EnergyGauge® (Version: FLRCNA-200)
r u, %
RIGHT-J LOAD AND EQUIPMENT SUMMARY
Entire House
FES, INC. Job: 01089 4/21/99
34 N.W. 168TH. STREET, NORTH MIAMI BEACH, FL 33169 Phone: 305-653-0212 Fax: 305-653-0232
For: SAVANNA CLUB APT
PLANCB2 BOT.; FL
Phone: WC=e
Notes:
Weather: Fort Lauderdale, FL, US
Winter Design Conditions
Outside db 46 OF
Inside db 71 OF
Design TD 25 OF
Heating Summary ,
Building heat loss
9484
Btuh
Ventilation air
0
cfm
Ventilation air loss
0
Btuh
Design heat load
9484
Btuh
Infiltration
Method
Simplified
Construction quality
Average
Fireplaces
0
Heating_ __
Cooling
Area (ft2)
�084
084�3
Volume (ft')
9756
9756
Air changes/hour
1.0
0.5
Equiv. AVF (cfm)
163
81
Heating Equipment Summary
Make n/a
Trade
n/a
' Efficiency
100.0 EFF
Heating input
0
Btuh
Heating output
0
Btuh
Heating temp rise
0
OF
Actual heating fan
443
cfm
• Heating air flow factor
0.047
cfm/Btuh
Space thermostat
Summer Design Conditions
Outside db
91
OF
Inside db
75
OF
Design TD
16
OF
Daily range
M
,
Relative humidity
50
%
Moisture difference
60
gr/lb
Sensible Cooling Equipment
Load
Sizing
Structure
10230
Btuh
Ventilation
1760
Btuh
Design temperature swing
3.0
OF
Use mfg. data
n
Rate/swing multiplier
0.96
Total sens. equip. load
11510
Btuh
Latent Cooling Equipment Load Sizing
Internal gains
690
Btuh
Ventilation
4064
Btuh
Infiltration
3311
Btuh
Total latent equip. load
8065
Btuh
Total equipment load 19575 Btuh
Cooling Equipment Summary
Make
Trade
Efficiency
0.0 EER
Sensible cooling
0
Btuh
Latent cooling
0
Btuh
Total cooling
0
Btuh
Actual cooling fan
443
cfm
Cooling air flow factor
0.043
cfm/Btuh
Load sensible heat ratio 60 %
Printout certified by ACCA to meet all requirements of Manual J 7th Ed.
,. Wriigj ltr!.c3 t Right -Suite ResidentialTM 5.0.45 RSR23656 2001-Jul-05 12:00:28
� HAWrightsoft LOAD CALCS\SAVANNA CLUBXPLAN B2 BOT.rsr Page 1
oil
Sr
1
S
oW
�5r
Ow
DO
n0 p
W
ZD4o
DCl)
c
om
cz
r0
D N
za
N
W OC
00
N
c
CA
N
W
N
W
088 J tD
O A W
N
-+
O
CO
co
J
M
CT
M4
X
A W N
D-IOrrtn
10rrfA
o_cwmc
g
�o v;
o CDZO
w Z
wwxm
O
O
ow-r2
=C
mw
'o i TG)
ww_x
moww
�ocmmc
N
_,
"
N O
CD
�• N O.
C N �.
(n
f0
CyP
tZi
M13 W rn
v Q
7
c: y y
�
C,
N N
O m
(O 3 CD
C '� N �'
y vOi N 61
N
0'
CD
N a
y
>> �,
(n 0.
n'
O
O
O N
O
O H
7 7 d
N o.
y 0
C -II
y O; O Z
-+...� C
CD 2 N fD y N
O.�
N y O p
7
3
y
X 0
O w=
w N
7
O
M
j ID'
w co
a
a
m• 0 3 C
rn
'^ fD O. O v w
"" N C1 0 CS w
�` N O. O Q w
O CJ w
ZZ
'^ N CS n C7 w
'O CD a 0 Cr w
��
OJ
A g P°
O•
n'
W
=JvCD
CO
n
mpm
W@
±
a
v
0z0E
Do2fnlA
agyZ=
ZOD
OM
-n3
r ^
cn
N
N N
=
N
N
O
O
O O O O A O
0 0 0 0 0
O O O N W
O A
0 0 0 0 01 0
O O O N W
fG
'O
W
'0OOG
O w W
00066 W
OOM.P W M
0001
0O(OA Ca 0
=
p
7
00
O
0000 CD
OOOOON
OO-r0��
OO
(D
000000
S : S : r x
00"0"-+
0
O
W
COOONO
00000-+
OOQO W,
OOO
OOO CO 00
C Q a 0 m m
+�00
TS
S
`%
m
O i i
: i:
N
W
w
•tO
0 0
e �W
O
co
()
V
00000 co
000000
O O
OOOCOO N
00 .N.�
W
000 V 00
CD
OOOOOJ
W W A
0000 V CA
-
,y1 Cp
A �xx :xr
A A
A
C1i
1+NV
N
x ::xx
V
x xxi
tOO.
aoCD
O
W
Go OD
A 0 0 0 A
O
0 0 0 p p O
0 0 0 0 0 0
P
O O O CT coO
O O N
O O O O O O
C
8 8x
'a
v
Co
A N N NCO
i
N 8 W
8
v
O.
A W C.)O O
(A OOOO OOO
W
A
OOOOOO
000000
OO CD
000OAA
OO CO
A
C OOCD OO
CD
O
»
O O
_
W A
w
0 p
0 0
�W
O
\
coW
V
00000 CD
OOOOp O
8
00. COO M
N
00�
(D
000SS J as
(D
000OGV
W
Op OO V
Z
x N
x
CD
`' O C.
.N -CD
ZA
A A A
A
» r r
�
r �i i
CD OOi
O
�j CD
Cl)
AOOO.P.
m
O
OOO O OO
OO OOOO
O OO OI CD O
OO N
CD CD 0 000
W
O
O_A
x $
x» x»
x S x x x x
to
w
O A A
00
W 0 0 0 0 0 0 0
A
0 0 0 0 0 0
O O O O O O
O O O
O O CCD
O O O CAD 0 0
w
�
ss� SS ss
SS
92
93
� � �
� x x x
� x r �
:I]
Y x x
♦ ♦
• ♦
.I ka s
RIGHT-J CALCULATION PROCEDURES A, B, C, D
Entire House
FES, INC. Job: 01089 4/2V99
34 N.W. 168TH. STREET, NORTH MIAMI BEACH, FL 33169 Phone: 305-653-0212 Fax: 305-653-0232
Procedure A - Winter Infiltration HTM Calculation*
1. Winter infiltration AVF
1.0 ach x 9756 ft3 x 0.0167 = 163 cfm
2. Winter infiltration load
1.1 x 163 cfm . x 25 OF Winter TD = 4480 Btuh
3. Winter infiltration HTM
4480 Btuh / 88 ft2 Total window = 50.9 Btuh/ft2
and door area
Procedure B - Summer Infiltration HTM Calculation
1. Summer infiltration AVF
0.5 ach x 9756 ft3 x 0.0167 = 81 cfm
2. Summer infiltration load
1.1 x 81 cfm x 16 OF Summer TD = 1434 Btuh
3. Summer infiltration HTM
1434 Btuh / 88 ft2 Total window = 16.3 Btuh/ft2
and door area
Procedure C - Latent Infiltration Gain
0.68 x 60 gr/lb moist.diff. x 81 cfm = 3311 Btuh
Procedure D - Equipment sizing toads
1. Sensible sizing load
Sensible ventilation load
1.1 x 100 cfm vent. x 16 OF Summer TD =
1760
Btuh
Sensible load for structure (Line 19) +
10230
Btuh
Sum of ventilation and structure loads =
11990
Btuh
Rating and temperature swing multiplier x
0.96
Equipment sizing load - sensible =
11510
Btuh
2. Latent sizing load
Latent ventilation load
0.68 x 100 cfm vent. x 60 gr/lb moist.diff. _ .
4064
Btuh
Internal loads = 230 Btuh x 3 people +
690
Btuh
Infiltration load from Procedure C +
3311
Btuh
Equipment sizing load - latent =
8065
Btuh
*Construction Quality is: a No. of Fireplaces is:, 0
Bol0talic values have been manually overridden
Printout certified by ACCA to meet all requirements of Manual J 7th Ed.
ASF.. Wr-jglhtSOft Right -Suite Residential*"' 5.0.45 RSR23656 2001-Jul-05 12:00:28