Loading...
HomeMy WebLinkAboutEnergy Codes�.t M .600A-97 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Community Affairs Residential Whole Building Performance Method A Project Name: SAVANNA CLUB,rPL�►N B1-1�0_P� Builder: Address: Permitting Office: PORT ST-1-UGIt City, State: Permit Number: Owner: Jurisdiction Number: (501Z00 Climate Zone: Central 1.- New construction or existing New _ 12. Cooling systems 2. Single family or multi -family Multi -family _ a. Central Unit 3. Number of units, if multi -family 1 _ 4° Number of Bedrooms 1 _ b. N/A 5. Is this a worst case? Yes _ 6. Conditioned floor area (ft2) 1013 ft? c. N/A 7. Glass area & type _ a. Clear -,single pane 96.0 ft2 _ 13. Heating systems b. Clear - double pane 0.0 ft2 _ a. Electric Strip c. Tint/other SC/SHGC - single pane 0.0 ft2 =d. Tint/other SC/SHGC -double pane 0.0 ft2 b. N/A 8. Floor types a. Slab -On -Grade Edge Insulation R=0.0, 84.0(p) ft _ c. N/A ' b. N/A _ c. N/A 14. Hot water systems 9. Wall types _ a. Electric Resistance a. Concrete, Int Insul, Exterior R=5.0, 336.0 ft2 _ b. Concrete, Int Insul, Adjacent R=5.0, 309.0 ft2 _ b. N/A c. N/A d. N/A _ c. Conservation credits e. N/A (HR-Heat recovery, Solar 10. Ceiling types _ DHP-Dedicated heat pump) a. Under Attic R=19.0, 1013.0 ft2 _ 15. HVAC credits b. N/A _ (CF-Ceiling fan, CV -Cross ventilation, c. N/A HF-Whole house fan, 11. Ducts _ PT -Programmable Thermostat, a. Sup: Con. Ret: Con. AH: Interior Sup. R=4.2, 30.0 ft _ RB-Attic radiant barrier, b. N/A MZ-C-Multizone cooling, MZ-H-Multizone heating) Glass/Floor Area: 0.09 Total as -built points: 11611.00` PASS Total base points: 12595.00 I hereby certify that the plans and specifications covered by this calculation are in compliance with the Florida Energy Code. PREPARED BY:,4140'10-v6 . <If-S , •��"�-• DATE: %S I hereby certify that this building, 'as design ',d, is in compliance with the Florida Enera, od . OWNER/AGENT: DATE: Cap: 24.3 kBtu/hr SEER: 10.00 Cap: 17.0 kBtu/hr COP: 1.00 Cap: 40.0 gallons _ EF: 0.89 Review of the plans and TA TIfE STE, specifications covered by this compliance O'e = ; o calculation indicates '"' with the Florida Energy Code. Before construction is completed "'�� "' .0 a this building will be inspected for compliance with. Section 553.908 C0 Florida Statutes. D�5`� we BUILDING OFFICIAL: DATE: EnergyGaugeO (Version: FLRCNA-200) 4 FORM 60OA-97 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Community Affairs Residential Whole Building Performance Method A Project Name: SAVANNA CLUB PLAN�"OP Builder: Address: Permitting Office: City, State: Permit Number: Owner: Jurisdiction Number: Climate Zone: Central 1. New construction or existing New _ 12. Cooling systems 2. Single family or multi -family Multi -family _ a. Central Unit 3. _ Number of units, if multi -family 1 _ 4. Number of Bedrooms 1 _ b. N/A 5. Is this a worst case? Yes 6. Conditioned floor area (ft2) _ 17QU Z c. N/A 7. Glass area & type _ a. Clear - single pane 96.0 ft2 _ 13. Heating systems b. Clear - double pane 0.0 ft2 _ a. Electric Strip c. Tint/other SC/SHGC - single pane 0.0 ft2 _ d. Tint/other SC/SHGC - double pane 0.0 ft2 b. N/A 8. Floor types .a. Slab -On -Grade Edge Insulation R=0.0, 84.0(p) ft _ c. N/A b. N/A _ c. N/A 14. Hot water systems 9. Wall types _ a. Electric Resistance a. Concrete, Int Insul, Exterior R=5.0, 336.0 ft2 _ b. Concrete, Int Insul, Adjacent R=5.0, 309.0 ft2 _ b. N/A c. N/A d. N/A _ c. Conservation credits e. N/A (HR-Heat recovery, Solar 10. Ceiling types _ DHP-Dedicated heat pump) a. Under Attic R-19.0, 1013.0 ft2 _ 15. HVAC credits b. N/A _ (CF-Ceiling fan, CV -Cross ventilation, c. N/A HF-Whole house fan, 11. Ducts _ PT -Programmable Thermostat, a. Sup: Con. Ret: Con. AH: Interior Sup. R=4.2, 30.0 ft _ RB-Attic radiant barrier, b. N/A MZ-C-Multizone cooling, MZ-H-Multizone heating) Glass/Floor Area: 0.09 Total as -built points: 11611.00 y PASS Total base points: 12595.00 I hereby certify that the plans and specifications covered by this calculation are in compliance with the Florida Energy Code. PREPARED BY:AWee. - SX4 r. er 1-vc. DATE: Sep I hereby certify that this building, as designed, is in compliance with the Florida Ener o OWNERIAGENT: DATE: /o/ Cap: 24.3 kBtu/hr _ SEER: 10.00 Cap: 17.0 kBtu/hr _ COP: 1.00 Cap: 40.0 gallons EF: 0.89 Review of the plans and ,sty sT aTFo specifications covered by this o4 = calculation indicates compliance with the Florida Energy Code. Before construction is completed this building will be inspected for tr compliance with Section 553.908 icon`��; Florida Statutes. WF BUILDING OFFICIAL: DATE: EnergyGauge® (Version: FLRCNA-200) FORM 60OA-97 SUMMER CALCULATIONS Residential Whole Building Performance Method A - Details ADDRESS: , , , PERMIT #: BASE AS -BUILT GLASS TYPES .$8 X Conditioned X BSPM = Points Overhang Floor Area Type/SC Ornt Len Hgt Area X SPM X SOF = Points .18 1013.0 42.08 7672.4 Single, Clear E 1.0 5.5' 20.0 59.31 0.96 1141.9 Single, Clear E 5.0 7.7 56.0 59.31 0.65 2164.6 Single, Clear E 1.0 5.5 20.0 59.31 0.96 1143.4 As -Built Total: 96.0 4449.9 WALL TYPES Area X BSPM = Points Type R-Value Area X SPM = Points Adajcent 309.0 0.7 216.3 Concrete, Int Insul, Exterior 5.0 336.0 1.00 336.0 Exterior 336.0 1.90 638.4 Concrete, Int Insul, Adjacent 5.0 309.0 0.60 185.4 Base Total: 645.0 854.7 As -Built Total: 645.0 521.4 DOOR TYPES Area X BSPM = Points Type Area X SPM = Points Adjacent 21.0 1.60 33.6 Adjacent Wood 21.0 2.40 50.4 Exterior 0.0 0.00 0.0 Base Total: 21.0 33.6 As -Built Total: 21.0 60.4 CEILING TYPES Area X BSPM = Points Type R-Value Area X SPM = Points Under Attic 1013.0 0.60 607.8 Under Attic 19.0 1013.0 1.10 1114.3 Base Total: 1013.0 607.8 As -Built Total: 1013.0 1114.3 FLOOR TYPES Area X BSPM = Points Type R-Value Area X SPM = Points Slab 84.0(p) -31.8 -2671.2 Slab -On -Grade Edge Insulation 0.0 84.0(p) -31.90 -2679.6 Raised 0.0 0.00 0.0 Base Total: -2671.2 As -Built Total: -2679.6 INFILTRATION Area X BSPM = Points Area X SPM = Points 1013.0 14.31 14496.0 1013.0 14.31 14496.0 Summer Base Points: 20993.3 Summer As -Built Points: 17952.4 Total Summer X System = Cooling Total X Cap X Duct X System X Credit = Cooling Points Multiplier Points Component Ratio Multiplier Multiplier Multiplier Points 17952.4 1.000 1 0.930 0.341 1.000 5693.3 20993.3 0.3577 7509.3 17962.4 1.00 0.930 0.341 1.000 5693.3 EnergyGaugeTM' DCA Form 60OA-97 FORM 60OA-97 WINTER CALCULATIONS Residential Whole Building Performance Method A - Details ADDRESS: , , , PERMIT #: BASE AS -BUILT GLASS TYPES .1'3 X Conditioned X BWPM = Points, Overhang Floor Area Type/SC Ornt Len Hgt Area X WPM X WOF = Points .18 1013.0 4.79 873.3 Single, Clear E 1.0 5.5 20.0 9.96 1.01 201.2 Single, Clear E 5.0 7.7 56.0 9.96 1.09 609.7 Single, Clear E 1.0 5.5 20.0 9.96 1.01 201.2 As -Built Total: 96.0 1012.1 WALL TYPES Area X BWPM = Points Type R-Value Area X WPM = Points Adajcent. 309.0 1.8 556.2 Concrete, Int Insul, Exterior 5.0 336.0 2.90 974.4 Exterior 336.0 2.00 672.0 Concrete, Int Insul, Adjacent 5.0 309.0 1.90 587.1 ESase Total: 645.0 1228.2 As -Built Total: 645.0 1561.5 DOOR TYPES Area X BWPM = Points Type Area X WPM = Points Adjacent 21.0 4.00 84.0 Adjacent Wood 21.0 5.90 123.9 Exterior 0.0 0.00 0.0 Base Total: 21.0 84.0 As -Built Total: 21.0 123.9 CEILING TYPES Area X BWPM = Points Type R-Value Area X WPM = Points Under Attic 1013.0 0.60 607.8 Under Attic 19.0 1013.0 1.00 1013.0 Base Total: 1013.0 607.8 As -Built Total: 1013.0 1013.0 FLOOR TYPES Area X BWPM = Points Type R-Value Area X WPM = Points Slab 84.0(p) -1.9 -159.6 Slab -On -Grade Edge Insulation 0.0 84.0(p) 2.50 210.0 Raised 0.0 0.00 0.0 Base Total: -159.6 As -Built Total: 210.0 INFILTRATION Area X BWPM = Points Area X WPM = Points 1013.0 -0.28 -283.6 1013.0 -0.28 -283.6 Winter Base Points: 2350.1 Winter As -Built Points: 3636.9. Total Winter X System = Heating Total X Cap X Duct X System X Credit = Heating Points Multiplier Points Component Ratio Multiplier Multiplier Multiplier Points 3636.9 1.000 0.930 1.000 1.000 3382.3 2350.1 1.0730 2521.6 3636.9 1.00 0.930 1.000 1.000 3382.3 EnergyGauge'rm DCA Form 60OA-97 FORM 60OA-97 WATER HEATING & CODE COMPLIANCE STATUS Residential Whole Building Performance Method A - Details ADDRESS: , , , PERMIT #: BASE I AS -BUILT WATER HEATING Number of X Multiplier = Total Tank EF Number of X Tank X Multiplier X Credit = Total Bedrooms Volume Bedrooms Ratio Multiplier 1 2564.00 2564.0 40.0 0.89 1 1.00 2535.19 1.00 2535.2 As -Built Total: 2535.2 CODE COMPLIANCE STATUS BASE AS -BUILT Cooling + Heating + Points Points Hot Water Points = Total Points Cooling Points + Heating + Hot Water = Total Points Points Points 7509.3 2521.6 2564.0 12595.0 6693.3 3382.3 2535.2 11610.8 IF PASS �oDWE� EnergyGaugeTm DCA Form 60OA-97 FORM 60OA-97 Code Compliance Checklist_ Residential Whole Building Pefformance Method A - Details I ADDRESS: , , , PERMIT #: I 6A-21 INFILTRATION REDUCTION COMPLIANCE CHECKLIST COMPONENTS SECTION REQUIREMENTS FOR EACH PRACTICE CHECK Exterior Windows & Doors 606.1.ABC.1.1 Maximum:.3 cfm/s .ft. window area; .5 cfm/s .ft. door area. Exterior & Adjacent Walls 606.1.ABC.1.2.1 Caulk, gasket, weatherstrip or seal between: windows/doors & frames, surrounding wall; foundation & wall sole or sill plate; joints between exterior wall panels at corners; utility penetrations; between wall panels & top/bottom plates; between walls and floor. EXCEPTION: Frame walls where a continuous infiltration barrier is installed that extends from and is sealed to the foundation to the top plate. Floors 606.1.ABC.1.2.2 Penetrations/openings >118" sealed unless backed by truss or joint members. EXCEPTION: Frame floors where a continuous infiltration barrier is installed that is sealed to the perimeter, penetrations and seams. Ceilings 606.1.ABC.1.2.3 Between walls & ceilings; penetrations of ceiling plane of top floor; around shafts, chases, soffits, chimneys, cabinets sealed to continuous air barrier; gaps in gyp board & top plate; attic access. EXCEPTION: Frame ceilings where a continuous infiltration barrier is installed that is sealed at the perimeter, at penetrations and seams. Recessed Lighting Fixtures 606.1.ABC.1.2.4 Type IC rated with no penetrations, sealed; or Type IC or non -IC rated, installed inside a sealed box with 1/2" clearance & 3" from insulation; or Type IC rated with < 2.0 cfm from conditioned space, tested. Multi -story Houses 606.1.ABC.1.2.5 Air barrier on perimeter of floor cavity between floors. Additional Infiltration reqts 606.1.ABC.1.3 Exhaust fans vented to outdoors, dampers; combustion space heaters comply with NFPA, have combustion air. RA-99 nTI41=P PRPCf_RIPTIVP MIPASI IRFC /mncf ha ma+ nr aar_parlpril by all rpsirlPnr-P_s_1 COMPONENTS SECTION REQUIREMENTS CHECK Water Heaters 612.1 Comply with efficiency requirements in Table 6-12. Switch or clearly marked circuit breaker electric or cutoff as must be provided. External or built-in heat trap required. Swimming Pools & Spas 612.1 Spas & heated pools must have covers (except solar heated). Non-commercial pools must have a pump timer. Gas spa & pool heaters must have a minimum thermal efficient of 78%. Shower heads 612.1 Water flow must be restricted to no more than 2.5 pallons per minute at 80 PSIG. Air Distribution Systems 610.1 All ducts, fittings, mechanical equipment and plenum chambers shall be mechanically attached, sealed, insulated, and installed in accordance with the criteria of Section 610. Ducts in unconditioned attics: R-6 min. insulation. HVAC Controls 607.1 Separate readily accessible manual or automatic thermostat for each system. Insulation 604.1, 602.1 Ceilings -Min. R-19. Common walls -Frame R-11 or CBS R-3 both sides. I Common ceiling & floors R-11. IF EnergyGaugeT'" DCA Form 60OA-97 EnergyGauge®/FlaRES'97 FLRCNA-200 c ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE SCORE* = 84.3 The higher the score, the more efficient the home. ' ' 1. New construction or existing New ' 12. Cooling systems 2. Single family or multi -family Multi -family _ a. Central Unit Cap: 24.3 kBtu/hr _ & Number of units, if multi -family 1 _ SEER: 10.00 _ 4. Number of Bedrooms 1 _ b. N/A 5. Is this a worst case? Yes 6. Conditioned floor area (ft2) 1013 ft2 c. N/A _ 7. Glass area & type _ _ a. Clear - single pane 96.0 ft2 _ 13. Heating systems b. Clear - double pane 0.0 ft2 _ a. Electric Strip Cap: 17.0 kBtu/hr _ .c. Tint/other SC/SHGC - single pane 0.0 ft2 _ COP: 1.00 _ d. Tint/other SC/SHGC - double pane 0.0 ft2 b. N/A _ 8. Floor types _ _ - a. Slab -On -Grade Edge Insulation R=0.0, 84.0(p) ft _ c. N/A _ b. N/A c. N/A 14. Hot water systems 9. Wall types _ a. Electric Resistance Cap: 40.0 gallons a. Concrete, Int Insul, Exterior R=5.0, 336.0 ft2 _ EF: 0.89 _ b. Concrete, Int Insul, Adjacent R=5.0, 309.0 ft2 _ b. N/A _ c. N/A d. N/A _ c. Conservation credits _ e. N/A (HR-Heat recovery, Solar 10. Ceiling types _ DIP -Dedicated heat pump) a. Under Attic R=19.0, 1013.0 ft2 _ 15. HVAC credits _ b. N/A _ (CF-Ceiling fan, CV -Cross ventilation, c. N/A BF -Whole house fan, 11. Ducts _ PT -Programmable Thermostat, a. Sup: Con. Ret: Con. AH: Interior Sup. R=4.2, 30.0 ft _ RB-Attic radiant barrier, b. N/A MZ-C-Multizone cooling, MZ-H-Multizone heating) I certify that this home has complied with the Florida Energy Efficiency Code For Building Construction through the above energy saving features which will be installed (or exceeded) ih this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature: Address of New Home: Date: City/FL Zip: *NOTE: The home's estimated energy performance score is only available through the FLARES computer program. This is not a Building Energy Rating. If your score is 80 or greater (or 86 for a US EPADOE EnergyStar''"designation), your home may qualms for energy efficiency mortgage (EEM incentives if you obtain a Florida Energy Gauge Rating. Contact the Energy Gauge Hotline at 4071638-1492 or see the Energy Gauge web site at www.fsec. ucf. edu for information and a list of certified Raters. For information about Florida's Energy Efficiency Code For Building Construction, contact the Department of Community Affairs at 8501487-1824. EnergyGauge® (Version: FLRCNA-200) RIGHT-J CALCULATION PROCEDURES A, B, C, D 0 Entire House FES, INC. Job:01089 4/21199 34 N.W. 168TH. STREET, NORTH MIAMI BEACH, FL 33169 Phone: 305-653-0212 Fax: 305-653-0232 Procedure A - Winter Infiltration HTM Calculation* 1. Winter infiltration AVF 1.0 ach x 9117 ft3 x 0.0167 = 152 cfm 2. Winter infiltration load 1.1 x 152 cfm x 25 OF Winter TD 4187 Btuh 3. Winter infiltration HTM 4187 Btuh / 117 ft2 Total window = 35.8 Btuh/ft2 and door area Procedure B - Summer Infiltration HTM Calculation 1. Summer infiltration AVF 0.5 ach x 9117 ft' x 0.0167 = 76 cfm 2. Summer infiltration load 1.1 x 76 cfm x 16 OF Summer TD = 1340 Btuh 3. Summer infiltration HTM 1340 Btuh / 117 ft2 Total window = 11.5 Btuh/ft2 and door area Procedure C - Latent Infiltration Gain 0.68 x60 gr/lb moist.diff. x 76 cfm = 3094 Btuh Procedure o - Equipment sizing Loads 1. Sensible sizing load Sensible ventilation load 1.1 x 100 cfm vent. x 16 OF Summer TD = 1760 Btuh Sensible load for structure (Line 19) + 13275 Btuh Sum of ventilation and structure loads = 15035 Btuh Rating and temperature swing multiplier x 0.96 Equipment sizing load - sensible = 14434 Btuh 2. Latent sizing load Latent ventilation load 0.68 x 100 cfm vent. x 60 gr/lb moist.diff. _ 4064 Btuh Internal loads = 230 Btuh x 3 people + 690 Btuh Infiltration load from Procedure C + 3094 Btuh Equipment sizing load - latent = 7848 Btuh *Construction Quality is: a No. of Fireplaces is: 0 1 Bold/itallo values have been manually overridden Printout certified by ACCA to meet all requirements of Manual J 7th Ed. wrighltsoft Right -Suite Residential^" 5.0.45 RSR23656 2001-Jul-05 11:57:42 / � HAWrightsoft LOAD CALCS\SAVANNA CLUB\PLAN B1 BOT.rsr Page 1 RIGHT-J LOAD AND EQUIPMENT SUMMARY Entire House FES, INC. Job:01089 4/21/99 34 N.W. 168TH. STREET, NORTH MIAMI BEACH, FL 33169 Phone: 305-653-0212 Fax: 305-653-0232 Project• • For: SAVANNA-CLUB.APT ((PLAN B1 TO.P,_FLJ Phone: K =e Notes: Weather: Fort Lauderdale, FL, US Winter Design. Conditions Summer Design Conditions Outside db 46 OF Outside db 91 OF Inside db 71 OF Inside db 75 OF Design TD 25 OF Design TD 16 OF Daily range M Relative humidity 50 % • Moisture difference 60 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Building heat loss 11634 Btuh Structure 13275 Btuh Ventilation air 0 cfm Ventilation 1760 Btuh Ventilation air loss 0 Btuh Design temperature swing 3.0 OF Design heat load 11634 Btuh Use mfg. data n Rate/swing multiplier 0.96 Infiltration Total sens. equip. load 14434 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Internal gains 690 Btuh Ventilation 4064 Btuh Heating Cooling Infiltration 3094 Btuh Area (ft') �1013 1-01-33 Total latent equip. load 7848 Btuh Volume (ft') 9117 9117 Air changes/hour 1.0 0.5 Total equipment load 22282 Btuh Equiv. AVF (cfm) 152 76 Heating Equipment Summary Cooling Equipment Summary Make n/a Make Trade Trade n/a Efficiency 100.0 EFF Efficiency 0.0 EER Heating input 0 Btuh Sensible cooling 0 Btuh Heating output 0 Btuh Latent cooling 0 Btuh Heating temp rise 0 OF Total cooling 0 Btuh Actual heating fan 575 cfm Actual cooling fan 575 cfm Heating air flow factor 0.049 cfm/Btuh Cooling air flow factor 0.043 cfm/Btuh Space thermostat Load sensible heat ratio 66 % Printout certified by ACCA to meet all requirements of Manual J 7th Ed. wraghtsoft Right -Suite ResidentialT"5.0.45 RSR23656 2001-Jul-05 11:57:42 .4M HAWrightsoft LOAD CALCSISAVANNA CLUBXPLAN B1 BOT.rsr Page 1 RIGHT-J WORKSHEET Entire House ' FES, INC. , Job:01089 4121199 34 N.W. 168TH. STREET, NORTH MIAMI BEACH, FL 33169 Phone: 305-653-0212 Fax: 305-653-0232 NWIVUAL J: /m to. 1 Name of room Entire House PLAN 131 2 Length of exposed wall 84.0 ft 84.0 ft 3 Room dimensions 10.0 x 101.3 ft 4 Ceiings Condit. Option 9.0 ftl d 9.0 ft heattcool TYPE OF CS HTM Area Load (Btuh) Area Load (Btuh) Area Area EXPOSURE NO. Htg Clg (ft� Htg Clg (ft� Htg I Clg Htg Clg Htg Clg 5 Gross a 14B 3.6 1.8 432 - '•*` 432 '*•' - •"• '••• '*•' *•*• Exposed b 12C 2.3 1.8 0 - "•' 0 - ••'• •'** •`** *•■• ••** walls and c 13N 1.4 0.6 330 "" •"' 330 •'•' - ' '* `•" •••• •••' partitions d 13C 0.9 1.0 0 "*' '•`• 0 `•`• ••'• ••*• •'•• ••** ***• 6 Windows and a 1B 26.1 " 96 2508 "'•' 96 2508 "'* •••• '**' glass doors b 813 26.1 '* 0 0 •'•" 0 0 "*•' •*•' •*" Heating c 0.0 " 0 0 - 0 0 "" `**■ •*`* d 0.0 " 0 0- 0 0 •'"' "" `"" e 0.0 *' 0 0- 0 0 *"' **•• *"• 7 Windows and North 27.8 26 `•* 735 26 `•'* 735 "" ••" glass doors NE/NW 0.0 0 ""• 0 0 "•' 0 •"' '*`* Cooling E/W 85.8 70 '•'• 5968 70 "" 5968 SE/SW 0.0 0 "" 0 0 "" 0 `•'* '*•' South 0.0 0 "*` 0 0 '•*' 0 `*'* •••' Harz 0.0 0 '•'• 0 0 "•' 0 8 Other doors a 10D 11.5 9.0 21 242 189 21 242 189 b 10A 14.0 11.0 0 0 0 0 0 0 c 0.0 0.0 0 0 0 0 0 0 9 Net a 14B 3.6 1.8 336 1210 595 336 1210 595 exposed b 12C 2.3 1.8 0 0 0 0 0 0 walls and c 13N 1.4 0.6 309 445 200 309 445 200 partitions d 13C 0.9 1.0 0 0 0 0 0 0 e 0.0 0.0 0 0 0 0 0 0 f 0.0 0.0 0 0 0 0 0 0 10 Ceilings. a 16D 1.3 2.1 1013 1342 2148 1013 1342 2148 b 0.0 0.0 0 0 0 0 0 0 c 0.0 0.0 0 0 0 0 0 0 d 0.0 0.0 0 0 0 0 0 0 e 0.0 0.0 0 0 0 0 0 0 f 0.0 0.0 0 0 0 0 0 0 11 Floors a 22A 20.3 0.0 84 1701 0 84 1701 0 (Note: room b 91A 4.8 2.2 0 0 0 0 0 0 perimeter c 0.0 0.0 0 0 0 0 0 0 is displ. d 0.0 0.0 0 0 0 0 0 0 for slab a 0.0 0.0 0 0 0 0 0 0 floors) f 0.0 0.0 0 0 0 0 0 0 12 Infiltration a 1 35.81 11.5 117 4187 1340 1171 4187 1340 13 Subtotal loss=6+8..+11+12 *•*' 11634 •"`* "•*` 11634 "'• "" `•:' ■•■* *•** Less external heating •'•' 0 `•" "**' 0 "" *••* '**' `••■ `••* Less transfer - 0 *■** •**• 0 •**• ••■■ ••** ..** **** 14 Duct loss 0% 0 "*' 0°/ 0 •"` °/ •"• °/ '•*• 15 Total loss =13+14 '*" 11634 "'• `•** 11634 "" '"" ••'• •"' •*•* 16 Int gains: People @ 300 3 "•• 900 3 "'•' 900 "•' *••' Appl. @ 1200 1 '*" 1200 1 •••' 1200 "••* 17 Subtot RSH gain=7+8..+12+16 •'•' "•• 13275 ••" - 13275 •"' "`•" ••"• "'"' Less external cooling '*" •••* 0 •**' ***• 0 •*** **•* *••* **** Less transfer **** *'*' 0 ■*•* **** 0 +•** **** ***■ •■■• 18 Duct gain 0% ***• 0 0°/ **** 0 °/ **+* °/ .... 19 Total RSH gain=(17+18)*PLF 1.00 13275 1.00 ••" 13275 '•" •*" 20 Air required (cfm) `*** 575 575 •'•" 575 575 •"` `••• Printout certified by ACCA to meet all requirements of Manual J 7th Ed. wraghtsoFC Right -Suite Residentialn" 5.0.45 RSR23656 2001-Jul-05 11:57:42 C5CA H:\Wrightsoft LOAD CALLS\SAVANNA CLUBIPLAN B1 BOT.rsr Page 1 A 0 FORM 60OA-97 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Community Affairs Residential Whole Building Performance Method A Project Name: SAVANNA CLUB'PLANi!32TtOP Builder: Address: Permitting Office: PORT ST-40C City, State: PORT ST LUCIE, FL Permit Number: Owner: RICH PROPERTIES Jurisdiction Number: 66 /200 Climate Zone: Central 1. New construction or existing New _ 12. Cooling systems 2. Single family or multi -family Multi -family _ a. Central Unit 3� Number of units, if multi -family 1 4. Number of Bedrooms 1 _ b. N/A 5. Is this a worst case? Yes 6. Conditioned floor area (ft2) _ 10$ 2' ' c. N/A 7. Glass area & type _ a. Clear - single pane 67.0 ft2 _ 13. Heating systems b. Clear - double pane 0.0 ft2 _ a. Electric Strip •c. Tintlother SC/SHGC - single pane 0.0 ft2 _ d. Tintlother SC/SHGC - double pane 0.0 ft2 b. N/A 8. Floor types a. Slab -On -Grade Edge Insulation R=0.0, 78.0(p) ft _ c. N/A b. N/A c. N/A 14. Hot water systems 9. Wall types _ a. Electric Resistance a. Frame, Wood, Exterior R=3.0, 110.0 ft2 _ b. Concrete, Int Insul, Adjacent R=3.0, 309.0 ft2 _ b. N/A c. N/A _ d. N/A _ c. Conservation credits e. N/A (HR-Heat recovery, Solar 10. Ceiling types _ DHP-Dedicated heat pump) a. Under Attic R=19.0, 1084.0 ft2 _ 15. HVAC credits b. N/A _ (CF-Ceiling fan, CV -Cross ventilation, c. N/A HF-Whole house fan, 11. Ducts _ PT -Programmable Thermostat, a. Sup: Con. Ret: Con. AH: Interior Sup. R=4.2, 40.0 ft _ RB-Attic radiant barrier, b. N/A MZ-C-Multizone cooling, MZ-H-Multizone heating) Glass/Floor Area: 0.06 Total as -built points: 11322.00 Y PASS Total base points: 12698.00 I hereby certify that the plans and specifications covered by this calculation are in compliance with the Florida Energy Code. PREPARED BY:Alifrl 510� -_ SJ T,vc DATE: L 5yof I hereby certify that this building, as designed, is in compliance with the Florida Ener o OWNER/AGENT: DATE: Cap: 26.0 kBtu/hr SEER: 10.00 Cap: 17.0 kBtu/hr COP: 1.00 Cap: 40.0 gallons _ EF: 0.89 Review of the plans and ST,9?� specifications covered by this indicates o�z� ti calculation compliance with the Florida Energy Code. d Before construction is completed 0 � a this building will be inspected for compliance with Section 553.908'coD Florida Statutes. wg��� BUILDING OFFICIAL: DATE: EnergyGauge® (Version: FLRCNA-200) S k FORM 60OA-97 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Community Affairs Residential Whole Building Performance Method A Project Name: SAVANNA CLUB PLAN 62 O-P Builder: Address: Permitting Office: City, State: PORT ST LUCIE, FL Permit Number: Owner: RICH PROPERTIES Jurisdiction Number: Climate Zone: Central 1. New construction or existing New _ 12. Cooling systems 2. Single family or multi -family Multi -family _ a. Central Unit Cap: 26.0 kBtu/hr _ 3. Number of units, if multi -family 1 _ SEER: 10.00 4. Number of Bedrooms 1 _ b. N/A _ 5. Is this a worst case? Yes 6. Conditioned floor area (ft2) 1084 ft? ` c. N/A _ 7. Glass area & type _ _ a. Clear - single pane 67.0 ft2 _ 13. Heating systems b. Clear - double pane 0.0 ft2 _ a. Electric Strip Cap: 17.0 kBtu/hr _ `c. Tint/other SC/SHGC - single pane 0.0 ft2 _ COP: 1.00 d. Tint/other SC/SHGC - double pane 0.0 ft2 b. N/A _ 8. Floor types _ _ ' a. Slab -On -Grade Edge Insulation R=0.0, 78.0(p) ft _ c. N/A _ b. N/A c. N/A 14. Hot water systems 9. Wall types _ a. Electric Resistance Cap: 40.0 gallons _ a. Frame, Wood, Exterior R=3.0, 110.0 ft2 _ EF: 0.89 _ b. Concrete, Int Insul, Adjacent R=3.0, 309.0 ft2 _ b. N/A c. N/A d. N/A _ c. Conservation credits _ e. N/A (HR-Heat recovery, Solar 10. Ceiling types _ DHP-Dedicated heat pump) a. Under Attic R=19.0, 1084.0 ft2 _ 15. HVAC credits b. N/A _ (CF-Ceiling fan, CV -Cross ventilation, c. N/A HF-Whole house fan, 11. Ducts _ PT -Programmable Thermostat, a. Sup: Con. Ret: Con. AH: Interior Sup. R=4.2, 40.0 ft _ RB-Attic radiant barrier, b. N/A MZ-C-Multizone cooling, MZ-H-Multizone heating) Glass/Floor Area: 0.06 Total as -built points: 11322.00 Y PASS Total base points: 12698.00 1-hereby certify that the plans and specifications covered by this calculation are in compliance with the Florida Energy Code. PREPARED BY:A/&rl Sllid s-�S , Ttic, DATE: hereby certify that this building, ip_ ned,is in compliance with the Florida En. OWNER/AGENT: DATE: d i Review of the plans and ,'THEs" specifications covered by this indicates compliance do calculation with the Florida Energy Code. Before construction is completed this building will be inspected for compliance with Section 553.908 11•o0D Florida Statutes. WE`D BUILDING OFFICIAL: DATE: EnergyGauge® (Version: FLRCNA-200) FORM 60OA-97 SUMMER CALCULATIONS e Residential Whole Building Performance Method A - Details ADDRESS: , PORT ST LUCIE, FL, PERMIT #: BASE AS -BUILT GLASS TYPES .18 X Conditioned X BSPM = Points Overhang Floor Area Type/SC Ornt Len Hgt Area X SPM X SOF = Points 18 1084.0 42.08 8210.2 Single, Clear E 1.0 5.5 '20.0 59.31 0.96 1141.9 Single, Clear E 1.0 5.5 27.0 59.31 0.96 1543.6 Single, Clear E 1.0 5.5 20.0 59.31 0.96 1143.4 As -Built Total: 67.0 3828.8 WALL TYPES Area X BSPM = Points Type R-Value Area X SPM = Points Adajcent 309.0 0.7 216.3 Frame, Wood, Exterior 3.0 110.0 4.64 510.7 Exterior 110.0 1.90 209.0 Concrete, Int Insul, Adjacent 3.0 309.0 0.70 216.3 Base Total: 419.0 425.3 As -Built Total: 419.0 727.0 DOOR TYPES Area X BSPM = Points Type Area X SPM = Points Adjacent 21.0 1.60 33.6 Adjacent Wood 21.0 2.40 50.4 Exterior 0.0 0.00 0.0 Base Total: 21.0 33.6 As -Built Total: 21.0 50.4 CEILING TYPES Area X BSPM = Points Type R-Value Area X SPM = Points Under Attic 1084.0 0.60 650.4 Under Attic 19.0 1084.0 1.10 1192.4 Base Total: 1084.0 650.4 As -Built Total: 1084.0 1192.4 FLOOR TYPES Area X BSPM = Points Type R-Value Area X SPM = Points Slab 78.0(p) -31.8 -2480.4 Slab -On -Grade Edge Insulation 0.0 78.0(p) -31.90 -2488.2 Raised 0.0 0.00 0.0 Base Total: -2480.4 As -Built Total: -2488.2 INFILTRATION Area X BSPM = Points Area X SPM = Points 1084.0 14.31 15512.0 1084.0 14.31 15512.0 a Summer Base Points: 22351.1 Summer As -Built Points: 18822.6 Total Summer X System = Cooling Total X Cap X Duct X System X Credit = Cooling Points Multiplier Points Component Ratio Multiplier Multiplier Multiplier Points 18822.5 1.000 1 0.930 0.341 1.000 5969.2 22351.1 0.3577 7995.0 18822.6 1.00 0.930 0.341 1.000 5969.2 EnergyGaugeTm DCA Form 60OA-97 FORM 60OA-97 WINTER G kCULATIONS Residential Whole Building Performance Method A - Details ADDRESS: , PORT ST LUCIE, FL, PERMIT #: BASE AS -BUILT GLASS TYPES .18 X Conditioned X BWPM = Points. Overhang Floor Area Type/SC Ornt Len Hgt Area X WPM X WOF = Points 18 1084.0 4.79 934.5 Single, Clear E 1.0 5.5 20.0 9.96 1.01 201.2 Single, Clear E 1.0 5.5 27.0 9.96 1.01 271.6 Single, Clear E 1.0 5.5 20.0 9.96 1.01 201.2 As -Built Total: 67.0 674.0 WALL TYPES Area X BWPM = Points Type R-Value Area X WPM = Points Adajcent 309.0 1.8 556.2 Frame, Wood, Exterior 3.0 110.0 4.96 545.3 Exterior 110.0 2.00 220.0 Concrete, Int Insul, Adjacent 3.0 309.0 2.30 710.7 Base Total: 419.0 776.2 As -Built Total: 419.0 1256.0 DOOR TYPES Area X BWPM = Points Type Area X WPM = Points Adjacent 21.0 4.00 84.0 Adjacent Wood 21.0 5.90 123.9 Exterior 0.0 0.00 0.0 Base Total: 21.0 84.0 As -Built Total: 21.0 123.9 CEILING TYPES Area X BWPM = Points Type R-Value Area X WPM = Points Under Attic 1084.0 0.60 650.4 Under Attic 19.0 1084.0 1.00 1084.0 Base Total: 1084.0 650.4 As -Built Total: 1084.0 1084.0 FLOOR TYPES Area X BWPM = Points Type R-Value Area X WPM = Points Slab 78.0(p) -1.9 -148.2 Slab -On -Grade Edge Insulation 0.0 78.0(p) 2.50 195.0 Raised 0.0 0.00 0.0 Base Total: -148.2 As -Built Total: 195.0 INFILTRATION Area X BWPM = Points Area X WPM = Points 1084.0 -0.28 -303.5 1084.0 -0.28 -303.5 Winter Base Points: 1993.4 Winter As -Built Points: 3029.4 Total Winter X System = Heating Total X Cap X Duct X System X Credit = Heating Points Multiplier Points Component Ratio Multiplier Multiplier Multiplier Points 3029.4 1.000 0.930 1.000 1.000 2817.3 1993.4 1.0730 2138.9 3029.4 1.00 0.930 1.000 1.000 2817.3 EnergyGaugeTm DCA Form 60OA-97 FORM 60OA-97 WATER HEATING & CODE COMPLIANCE STATUS Residential Whole Building Performance Method A - Details ADDRESS: , PORT ST LUCIE, FL, PERMIT #: BASE AS -BUILT WATER HEATING Number of X Multiplier = Total . Tank EF Number of X Tank X Multiplier X Credit = Total Bedrooms Volume Bedrooms Ratio Multiplier 1 2564.00 - 2564.0 40.0 0.89 1 1.00 2535.19 1.00 2535.2 As -Built Total: 2535.2 CODE COMPLIANCE STATUS BASE AS -BUILT Cooling + Heating + Points Points Hot Water Points = Total Points Cooling Points + Heating + Hot Water = Total Points Points Points 7996.0 2138.9 2564.0 12697.9 5969.2 2817.3 2536.2 11321.7 PASS EnergyGauge'rm DCA Form 60OA-97 FORM 60OA-97 Code Compliance Checklist Residential Whole Building Performance Method A - Details ADDRESS: , PORT ST LUCIE, FL, PERMIT #: 6A-21 INFILTRATION REDUCTION COMPLIANCE CHECKLIST COMPONENTS SECTION REQUIREMENTS FOR EACH PRACTICE CHECK Exterior Windows & Doors 606.1.ABC.1.1 Maximum:.3 cfm/s .ft. window area; .5 cfm/s .ft. door area. Exterior & Adjacent Walls 606.1.ABC.1.2.1 Caulk, gasket, weatherstrip or seal between: windows/doors & frames, surrounding wall; foundation & wall sole or sill plate; joints between exterior wall panels at comers; utility penetrations; between wall panels & top/bottom plates; between walls and floor. EXCEPTION: Frame walls where a continuous infiltration barrier is installed that extends from and is sealed to the foundation to the top plate. Floors 606.1.ABC.1.2.2 Penetrations/openings >1/8" sealed unless backed. by truss or joint members. EXCEPTION: Frame floors where a continuous infiltration barrier is installed that is sealed to the perimeter, penetrations and seams. Ceilings 606.1.ABC.1.2.3 Between walls &.ceilings; penetrations of ceiling plane of top floor; around shafts, chases, soffits, chimneys, cabinets sealed to continuous air barrier; gaps in gyp board & top plate; attic access. EXCEPTION: Frame ceilings where a continuous infiltration barrier is installed that is sealed at the perimeter, at penetrations and seams. Recessed Lighting Fixtures 606.1.ABC.1.2.4 Type IC rated with no penetrations, sealed; or Type IC or non -IC rated, installed inside a sealed box with 1/2" clearance & 3" from insulation; or Type IC rated with < 2.0 cfm from conditioned space, tested. Multi -story Houses 606.1.ABC.1.2.5 Air barrier on perimeter of floor cavity between floors. Additional Infiltration reqts 606.1.ABC.1.3 Exhaust fans vented to outdoors, dampers; combustion space heaters comply with NFPA, have combustion air. FA-99 nT1411=R PRFCf_RIPTIVF MPASI IPPA /mnef ha ma+ nr axcparlprl by all rpc11rlPncps_1 COMPONENTS SECTION REQUIREMENTS CHECK Water Heaters 612.1 Comply with efficiency requirements in Table 6-12. Switch or clearly marked circuit breaker electric or cutoff as must be provided. External or built-in heat trap required. Swimming Pools & Spas 612.1 Spas & heated pools must have covers (except solar heated). Non-commercial pools must have a pump timer. Gas spa & pool heaters must have a minimum thermal efficiency of 78%. Shower heads 612.1 Water flow must be restricted to no more than 2.5 gallons per minute at 80 PSIG. Air Distribution Systems 610.1 All ducts, fittings, mechanical equipment and plenum chambers shall be mechanically attached, sealed, insulated, and installed in accordance with the criteria of Section 610. Ducts in unconditioned attics: R-6 min. insulation. HVAC Controls 607.1 Separate readily accessible manual or automatic thermostat for each system. Insulation 604.1, 602.1 Ceilings -Min. R-19. Common walls -Frame R-11 or CBS R-3 both sides. Common ceiling & floors R-11. EnergyGaugeTm DCA Form 60OA-97 EnergyGauge®/FlaRES'97 FLRCNA-200 J 11 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE SCORE* = 85.2 The higher the score, the more efficient the home. RICH PROPERTIES,, PORT ST LUCIE, FL, 1. New construction or existing New _ 12. Cooling systems 2. Single family or multi -family Multi -family _ a. Central Unit Cap: 26.0 kBtu/hr _ 3. Number of units, if multi -family 1 _ SEER: 10.00 4. Number of Bedrooms 1 _ b. N/A _ 5. Is this a worst case? Yes 6. Conditioned floor area (ft2) 108 _ft2 c. N/A 7. Glass area & type a. Clear - single pane 67.0 ft2 _ 13. Heating systems b. Clear - double pane 0.0 ft2 _ a. Electric Strip Cap: 17.0 kBtu/hr ' c. Tint/other SC/SHGC - single pane 0.0 ft2 _ COP: 1.00 _ d. Tint/other SC/SHGC - double pane 0.0 ft2 b. N/A _ 8. Floor types _ _ a. Slab -On -Grade Edge Insulation R=0.0, 78.0(p) ft _ c. N/A _ b. N/A c. N/A 14. Hot water systems 9. Wall types _ a. Electric Resistance Cap: 40.0 gallons a. Frame, Wood, Exterior R=3.0, 110.0 ft2 _ EF: 0.89 b. Concrete, hit Insul, Adjacent R=3.0, 309.0 ft2 _ b. N/A _ c. N/A d. N/A _ c. Conservation credits _ e. N/A (HR-Heat recovery, Solar 10. Ceiling types _ DHP-Dedicated heat pump) a. Under Attic R=19.0, 1084.0 ft2 _ 15. HVAC credits _ b. N/A _ (CF-Ceiling fan, CV -Cross ventilation, c. N/A HF-Whole house fan, 11. Ducts _ PT -Programmable Thermostat, a. Sup: Con. Ret: Con. AH: Interior Sup. R=4.2, 40.0 ft _ RB-Attic radiant barrier, b. N/A MZ-C-Multizone cooling, MZ-H-Multizone heating) I certify that this home has complied with the Florida Energy Efficiency Code For Building c Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature: Date: Address of New Home: City/FL Zip: *NOTE: The home's estimated energy performance score is only available through the FLARES computer program. This is not a Building Energy Rating. If your score is 80 or greater (or 86 for a US EPADOE EnergyStar'mdesignation), your home may qualify for energy efficiency mortgage (EEM incentives ifyou obtain a Florida Energy Gauge Rating. Contact the Energy Gauge Hotline at 4071638-1492 or see the Energy Gauge web site at www.fsec. ucf. edu for information and a list of certified Raters. For information about Florida's Energy Efficiency Code For Building Construction, contact the Department of Community Affairs at 8501487-1824. EnergyGauge® (Version: FLRCNA-200) RIGHT-J LOAD AND EQUIPMENT SUMMARY Entire House FES, INC. Job: 01089 4121199 34 N.W. 166TH. STREET, NORTH MIAMI BEACH, FL 33169 Phone: 305-653-0212 Fax: 305-653-0232 Project• • For: SAVANNA CLUB APT PLAN-132-TOP; FL3 Phone: WG e Notes: Design Information Weather: Fort Lauderdale, FL, US Winter Design Conditions Summer Design Conditions Outside db 46 OF Outside db 91 OF Inside db 71 OF Inside db 75 OF Design TD 25 OF Design TD 16 OF Daily range M Relative humidity 50 % Moisture difference 60 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Building heat loss 10920 Btuh Structure 12528 Btuh Ventilation air 0 cfm Ventilation 1760 Btuh Ventilation air loss 0 Btuh Design temperature swing 3.0 OF Design heat load 10920 Btuh Use mfg. data n Rate/swing multiplier 0.96 Infiltration Total sens. equip. load 13716 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Internal gains 690 Btuh Ventilation 4064 Btuh Heating Cooling Infiltration 3311 Btuh Area (ft2) �10-4 1084 Total latent equip. load 8065 Btuh Volume (ft3) 9756 9756 Air changes/hour 1.0 0.5 Total equipment load 21781 Btuh Equiv. AVF (cfm) 163 81 Heating Equipment Summary Cooling Equipment Summary Make n/a Make Trade Trade n/a Efficiency 100.0 EFF Efficiency 0.0 EER Heating input 0 Btuh Sensible cooling 0 Btuh Heating output 0 Btuh Latent cooling 0 Btuh Heating temp rise 0 OF Total cooling 0 Btuh Actual heating fan 542 cfm Actual cooling fan 542 cfm Heating air flow factor 0.050 cfm/Btuh Cooling air flow factor 0.043 cfm/Btuh Space thermostat Load sensible heat ratio 64 % Printout certified by ACCA to meet all requirements of Manual J 7th Ed. .jQ_t� wrjghtsoft Right -Suite ResidentialT 5.0.45 RSR23656 2001-Jul-05 12:05:01 ACCk H:1Wrightsoft LOAD CALCSISAVANNA CLUBTLAN B2 TOP.rsr Page 1 oil :3 0 C 0 CD CD n D_ O 3 CD 3 CD a co 0 �-q 9 O f0 W V D7 w A W N O co co V 0) N m X A W N> DO NNC .�-. OC�NtDC O NNZ rD rD c,^ CD I5T�1 CDO G7 Era,. 0 rG �.iNN� 0�'N3NM. O 7 _ `z.�'NO cz CD ON .01n NN C. Vl O. ._7.,N ,DO ..NO, �� O m j0f0 3� 3� m a ro a m° d C rD y CD a°, a�i cl " 60, A 0. t� Q• H V) >> 1D CL a o o o ro o f o 1D N N » o n cn p � rn p z 0 rD = N (O N y NCD p 7 O N n 00 O O y y n C T C 3 n O D) 11 N 0 3 tD N n n m ID 3 22 W 11 y'D 0 Cf�f =II O 3• + N W \ N rn ^CD n0 Cd �tD n0QN �fD O.O QN O O'N [iI m2Zo �'W dO CT 0) -'�N n0 QtD ° 11 D('pD A �:•� G Cj N » OD -+ ZCi CO ma O ro N O o O D� O 0Znm co asczZ W� nZn� Ow o — CD N n O O 000 A O 00 000 — O 00> N W O A-+ 000000) 00 O> N W f0 'O CO 0000 W W C0000 W G OrOA W 0 60 C", OOGO» 00 (D.P. W 0) = 0 O O OO 00 O»> CCDn O �=00>O»O CD 00 COOOOONO 00000> OOG CD coDD 000 OOOdD00 0000I OD co »O O r 00 07 V W Cl) O N T D) W W A N O 7 os >W o co 00 V CT y1 N �r} 60 CD co0AD W A A A N m O. coC O CD A N 0000 O O m 000000 00000 0 A 000 CT CO O 00 N 00 0000 W v N N i i i N OCD 0) > A i S O. AN N 00 N co CD 00 aD 00 W A 000000 CNO 00000 W OOOOAA OD OOCO 000 0000 ! i D _ v O 0 O s 00 >W 0 Co co V p p 00 OCD poppp pppOOA OOOt0 O01 00 O00 V pp O pppOV W W A 0000 V 01 .=0 Z x 113 }S i S S *S 6DOj Ot • • • » • » O O co CD A A r71 A A N V A N A i s a V #; n `'pWN OD 0 A N N N O O O O O tb O co O O O O O O W 0 0 0 0 0 0) A A O O O CT W O O O N cn O O O O O O W O_ A Er x N N> AN N 00 i S (A(,�� N coN ca OCO0) CD CT A i i i S N ODOOOp 00 A 000000 00000 fD OOOOAA Coco OOOCa 00 a7 x i i i i i i y i CO d 35 liSi2 ro n,;a N Z n N� 2O 'AA '^ V/ m m I I RIGHT-J CALCULATION PROCEDURES A, B, C, D Entire House 0 FES, INC. Job: 01089 4121199 34 N.W. 168TH. STREET, NORTH MIAMI BEACH, FL 33169 Phone: 305-653-0212 Fax: 305-653-0232 Procedure A - Winter Infiltration HTM Calculation* 1. Winter infiltration AVF 1.0 ach x 9756 ft3 x 0.0167 = 163 cfm 2. Winter infiltration load 1.1 x 163 cfm x 25 OF Winter TD = 4480 Btuh 3. Winter infiltration HTM 4480 Btuh / 88 ft2 Total window = 50.9 Btuh/ft2 and door area Procedure B - Summer Infiltration HTM Calculation 1. Summer infiltration AVF 0.5 ach x 9756 ft3 x 0.0167 = 81 cfm 2. Summer infiltration load 1.1 x 81 cfm x 16 OF Summer TD = 1434 Btuh 3. Summer infiltration HTM 1434 Btuh / 88 ft2 Total window = 16.3 Btuh/ft2 and door area Procedure C - Latent Infiltration Gain 0.68 x 60 gr/lb moist.diff. x 81 cfm = 3311 Btuh -roceclure U - Equipment sizing Loacis 1. Sensible sizing load Sensible ventilation load 1.1 x 100 cfm vent. x 16 Sensible load for structure (Line 19) Sum of ventilation and structure loads Rating and temperature swing multiplier Equipment sizing load - sensible 2. Latent sizing load Latent ventilation load OF Summer TD = x 0.68 x 100 cfm vent. x 60 gr/lb moist.diff Internal loads = 230 Btuh x 3 people Infiltration load from Procedure C Equipment sizing load - latent `Construction Quality is: a +Y 1760 Btuh 12528 Btuh 14288 Btuh 0.96 13716 Btuh 4064 Btuh 690 Btuh 3311 Btuh 8065 Btuh No. of Fireplaces is: 0 BoWitalic values have been manually overridden Printout certified by ACCA to meet all requirements of Manual J 7th Ed. S wrightsoft Right -Suite Residential"" 5.0.45 RSR23656 2001-Jul-05 12:05:01 M. H:%Wrightsoft LOAD CALCS\SAVANNA CLUBIPLAN B2 TOP.rsr Page 1 I FORM 600A-97 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Community Affairs Residential Whole Building Performance Method A Project Name: SAVANNA CLUB PLAN A1-13OTTOM Builder: Address: Permitting Office: p09T %7- AociE City, State: PORT ST LUCIE, FL Permit Number: Owner: RICH PROPERTIES Jurisdiction Number: 66/A00 Climate Zone: Central 1. New construction or existing New _ 12. Cooling systems 2. Single family or multi -family Multi -family _ a. Central Unit S. Number of units, if multi -family 1 4. Number of Bedrooms 1 _ b. N/A 5. Is this a worst case? Yes _ 6. Conditioned floor area (ft2) 814`ftz c. N/A 7. Glass area & type a. Clear - single pane 54.0 ft2 _ 13. Heating systems b. Clear - double pane 0.0 ft2 _ a. Electric Strip c. Tintlother SC/SHGC - single pane 0.0 ft2 _ d. Tint/other SC/SHGC - double pane 0.0 ft2 b. N/A $. Floor types a. Slab -On -Grade Edge Insulation R=0.0, 98.0(p) ft _ c. N/A b. N/A _ c. N/A 14. Hot water systems 9. Wall types _ a. Electric Resistance a. Concrete, Int Insul, Exterior R=3.0, 450.0 ft2 _ b. Concrete, Int Insul, Adjacent R=3.0, 304.5 ft2 _ b. N/A c. N/A _ d. N/A _ c. Conservation credits e. N/A (HR-Heat recovery, Solar 10. Ceiling types _ DHP-Dedicated heat pump) a. N/A _ 15. HVAC credits b. N/A _ (CF-Ceiling fan, CV -Cross ventilation, c. N/A HF-Whole house fan, 11. Ducts _ PT -Programmable Thermostat, a. Sup: Con. Ret: Con. AH: Interior Sup. R=4.2, 30.0 ft _ RB-Attic radiant barrier, b. N/A MZ-C-Multizone cooling, MZ-H-Multizone heating) Glass/Floor Area: 0.06 Total as -built points: 9667.60 r PASS Total base points: 10844.00 r hereby certify that the plans and specifications covered by this calculation are in compliance with the Florida Energy Code. PREPARED BY: A/lbef-O' 54d6 9'65 -X"ac DATE: a! I hereby certify that this building, as-desig7i d, is in compliance with the Florida Energy • OWNER/AGENT: zildffle DATE: EnergyGaugeO (Version: FLRCNA-200) Cap: 21.5 kBtu/hr SEER:10.00 _ Cap: 17.0 kBtu/hr _ COP: 1.00 _ Cap: 30.0 gallons EF: 0.89 Review of the plans and ztE sT specifications covered by this yo4 calculation indicates compliance with the Florida Energy Code. Before construction is completed y this building will be.inspected for compliance with Section 553.908 �•0on� Florida Statutes. BUILDING OFFICIAL: DATE: C FORM 60OA-97 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Community Affairs Residential Whole Building Performance Method A Project Name: SAVANNA CLUB PLAN;A'hBOTTOM Builder: Address: Permitting Office: City, State: PORT ST LUCIE, FL Permit Number: Owner: RICH -PROPERTIES Jurisdiction Number: Climate Zone: Central 1. New construction or existing New _ 12. Cooling systems 2. Single family or multi -family Multi -family _ a. Central Unit 3. Number of units, if multi -family 1 _ 4. Number of Bedrooms 1 _ b. N/A 5. Is this a worst case? Yes 6. Conditioned floor area (ft2) 89 1 c. N/A 7. Glass area & type _ a. Clear - single pane 54.0 ft2. _ 13. Heating systems b. Clear - double pane 0.0 ft2 _ a. Electric Strip c. Tint/other SC/SHGC - single pane 0.0 ft2 _ d. Tint/other SC/SHGC - double pane 0.0 ft2 b. N/A S. Floor types a. Slab -On -Grade Edge Insulation R=0.0, 98.0(p) ft _ c. N/A b. N/A c. N/A 14. Hot water systems 9. Wall types _ a. Electric Resistance a. Concrete, Int. Insul, Exterior R=3.0, 450.0 ft2 _ b. Concrete, Int Insul, Adjacent R=3.0, 304.5 ft2 _ b. N/A c. N/A d. N/A _ c. Conservation credits e. N/A (HR-Heat recovery, Solar 10. Ceiling types _ DHP-Dedicated heat pump) a. N/A _ 15. HVAC credits b. N/A _ (CF-Ceiling fan, CV -Cross ventilation, c. N/A BF -Whole house fan, 11. Ducts _ PT -Programmable Thermostat, a. Sup: Con. Ret: Con. AH: Interior Sup. R=4.2, 30.0 ft _ RB-Attic radiant barrier, b. N/A MZ-C-Multizone cooling, MZ-H-Multizone heating) Glass/Floor Area: 0.06 Total as -built points: 9667.60 Y PASS Total base points: 10844.00 1 hereby certify that the plans and specifications covered by this calculation are in compliance with the Florida Energy Code. PREPARED BY: Adfe-1 Sod F.55 .4 Zut DATE: ? SOF I hereby certify that this building, as designed, is in compliance with the Florida Energy ode OWNER/AGENT: DATE: Cap: 21.5 kBtu/hr _ SEER- 10.00 Cap: 17.0 kBtu/hr COP: 1.00 Cap: 30.0 gallons EF: 0.89 Review of the plans and ZtE sT aT�o specifications covered by this o� = calculation indicates compliance with the Florida Energy Code. Before is completed construction a this building will be inspected for compliance with Section 553.908 •COD Florida Statutes. {NE BUILDING OFFICIAL: DATE: EnergyGauge® (Version: FLRCNA-200) FORM 60OA-97 SUMMER CALCULATIONS Residential Whole Building Performance Method A - Details ADDRESS: , PORT ST LUCIE, FL, PERMIT #: BASE AS -BUILT GLASS TYPES .18 X Conditioned X BSPM = Points - Overhang Floor Area Type/SC Ornt Len Hgt Area X SPM X SOF = Points '.18 894.0 42.08 6771.1 Single, Clear E 1.0 5.5 27.0 59.31 0.96 1543.6 Single, Clear E 1.0 5.5 20.0 59.31 0.96 1143.4 Single, Clear S 1.0 4.3 7.0 44.66 0.88 274.5 As -Built Total: 54.0 2961.4 WALL TYPES Area X BSPM = Points Type R-Value Area X SPM = Points Adajcent 304.5 0.7 213.1 Concrete, Int Insul, Exterior 3.0 450.0 1.40 630.0 Exterior 450.0 1.90 855.0 Concrete, Int Insul, Adjacent 3.0 304.5 0.70 213.1 Base Total: 754.5 1068.1 As -Built Total: 754.5 843.2 DOOR TYPES Area X BSPM = Points Type Area X SPM = Points Adjacent 21.0 1.60 33.6 Adjacent Wood 21.0 2.40 50.4 Exterior 0.0 0.00 0.0 Base Total: 21.0 33.6 As -Built Total: 21.0 50.4 CEILING TYPES Area X BSPM = Points Type R-Value Area X SPM = Points Under Attic 0.0 0.00 0.0 Base Total: 0.0 0.0 As -Built Total: 0.0 0.0 FLOOR TYPES Area X BSPM = Points Type R-Value Area X SPM = Points Slab 98.0(p) -31.8 -3116.4 Slab -On -Grade Edge Insulation 0.0 98.0(p) -31.90 -3126.2 Raised 0.0 0.00 0.0 Base Total: -3116.4 As -Built Total: -3126.2 INFILTRATION Area X BSPM = Points Area X SPM = Points 894.0 14.31 12793.1 894.0 14.31 12793.1 Summer Base Points: 17549.6 Summer As -Built Points: 13521.9 Total Summer X System = Cooling Total X Cap X Duct X System X Credit = Cooling Points Multiplier Points Component Ratio Multiplier Multiplier Multiplier Points 13521.9 1.000 0.930 0.341 1.000 4288.2 17549.6 0.3577 6277.6 13521.9 1.00 0.930 0.341 1.000 4288.2 EnergyGaugeTm DCA Form 60OA-97 FORM 60OA-97 WINTER CALCULATIONS Residential Whole Building Performance Method A - Details ADDRESS: , PORT ST LUCIE, FL, PERMIT #: BASE AS -BUILT GLASS TYPES .18 X Conditioned X BWPM = Points. Overhang Floor Area Type/SC Ornt Len Hgt Area X WPM X WOF = Points .18 894.0 4.79 770.7 Single, Clear E 1.0 5.5 27.0 9.96 1.01 271.6 Single, Clear E 1.0 5.5 20.0 9.96 1.01 201.2 Single, Clear S 1.0 4.3 7.0 7.73 1.04 56.5 As -Built Total: 54.0 529.3 WALL TYPES Area X BWPM = Points Type R-Value Area X WPM = Points Adajcent 304.5 1.8 548.1 Concrete, Int Insul, Exterior 3.0 450.0 3.80 1710.0 Exterior 450.0 2.00 900.0 Concrete, Int Insul, Adjacent 3.0 304.5 2.30 700.3 Base Total: 754.6 1448.1 As -Built Total: 754.5 2410.4 DOOR TYPES Area X BWPM = Points Type Area X WPM = Points Adjacent 21.0 4.00 84.0 Adjacent Wood 21.0 5.90 123.9 Exterior 0.0 0.00 0.0 Base Total: 21.0 84.0 As -Built Total: 21.0 123.9 CEILING TYPES Area X BWPM = Points Type R-Value Area X WPM = Points Under Attic 0.0 0.00 0.0 Base Total: 0.0 0.0 As -Built Total: 0.0 0.0 FLOOR TYPES Area X BWPM = Points Type R-Value Area X WPM = Points Slab 98.0(p) -1.9 -186.2 Slab -On -Grade Edge Insulation. 0.0 98.0(p) 2.50 245.0 Raised 0.0 0.00 0.0 Base Total: -186.2 As -Built Total: 245.0 INFILTRATION Area X BWPM = Points Area X WPM = Points 894.0 -0.28 -250.3 894.0 -0.28 -250.3 Winter Base Points: 1866.3 Winter As -Built Points: 3058.3 Total Winter X System = Heating Total X Cap X Duct X System. X Credit = Heating Points Multiplier Points Component Ratio Multiplier Multiplier Multiplier Points 3058.3 1.000 0.930 1.000 1.000 2844.2 1866.3 1.0730 2002.6 3058.3 1.00 0.930 1.000 1.000 2844.2 EnergyGaugeTm DCA Form 60OA-97 FORM 60OA-97 WATER HEATING & CODE COMPLIANCE STATUS Residential Whole Building Performance Method A - Details ADDRESS: , PORT ST LUCIE, FL, PERMIT #: BASE AS -BUILT VVATER HEATING Number of X Multiplier = Total Tank EF Number of X Tank X Multiplier X Credit = Total Bedrooms Volume Bedrooms Ratio Multiplier 1 2564.00 2564.0 30.0 0.89 1 1.00 2535.19 1.00 2535.2 As -Built Total: 2535.2 CODE COMPLIANCE STATUS BASE AS -BUILT Cooling + Heating + Points Points Hot Water Points = Total Points Cooling Points + Heating + Hot Water = Total Points Points Points 6277.5 2002.6 2564.0 10844.0 4288.2 2844.2 2535.2 9667.6 PASS EnergyGaugeTm DCA Form 60OA-97 FORM 60OA-97 Code Compliance Checklist Residential Whole Building Performance Method A - Details ADDRESS: , PORT ST LUCIE, FL, PERMIT #: 6A-21 INFILTRATION REDUCTION COMPLIANCE CHECKLIST COMPONENTS SECTION REQUIREMENTS FOR EACH PRACTICE CHECK Exterior Windows & Doors 606.1.ABC.1.1 Maximum:.3 cfm/s .ft. window area; .5 cfm/s .ft. door area. Exterior & Adjacent Walls 606.1.ABC.1.2.1 Caulk, gasket, weatherstrip or seal between: windows/doors & frames, surrounding wall; foundation & wall sole or sill plate; joints between exterior wall panels at corners; utility penetrations; between wall panels & top/bottom plates; between walls and floor. EXCEPTION: Frame walls where a continuous infiltration barrier is installed that extends from and is sealed to the foundation to the top plate. Floors 606.1.ABC.1.2.2 Penetrations/openings >1/8" sealed unless backed by truss or joint members. EXCEPTION: Frame floors where a continuous infiltration barrier is installed that is sealed to the perimeter, penetrations and seams. Ceilings 606.1.ABC.1.2.3 Between walls & ceilings; penetrations of ceiling plane of top floor; around shafts, chases, soffits, chimneys, cabinets sealed to continuous air barrier; gaps in gyp board & top plate; • attic access. EXCEPTION: Frame ceilings where a continuous infiltration barrier is installed that is sealed at the perimeter, at penetrations and seams. Recessed Lighting Fixtures 606.1.ABC.1.2.4 Type IC rated with no penetrations, sealed; or Type IC or non -IC rated, installed inside a sealed box with 1/2" clearance & 3"from insulation; or Type IC rated with < 2.0 cfm from conditioned space, tested. Multi -story Houses 606.1.ABC.1.2.5 Air barrier on perimeter of floor cavity between floors. Additional Infiltration reqts 606.1.ABC.1.3 Exhaust fans vented to outdoors, dampers; combustion space heaters comply with NFPA, have combustion air. &A_99 n rUCO 001=09`0I01rI\/C IIACACI IRGC /mncf ha ma4 nr avraarlarl by all ra4irla_nCP_C _I COMPONENTS SECTION REQUIREMENTS CHECK Water Heaters 612.1 Comply with efficiency requirements in Table 6-12. Switch or clearly marked circuit breaker electric or cutoff as must be provided. External or built-in heat trap required. Swimming Pools & Spas 612.1 Spas & heated pools must have covers (except solar heated). Non-commercial pools must have a pump timer. Gas spa & pool heaters must have a minimum thermal. efficiency of 78%. Shower heads 612.1 Water flow must be restricted to no more than 2.5 gallons per minute at 80 PSIG. Air Distribution Systems 610.1 All ducts, fittings, mechanical equipment and plenum chambers shall be mechanically attached, sealed, insulated, and installed in accordance with the criteria of Section 610. Ducts in unconditioned attics: R-6 min. insulation. HVAC Controls 607.1 Separate readily accessible manual or automatic thermostat for each system. Insulation 604.1, 602.1 Ceilings -Min. R-19. Common walls -Frame R-11 or CBS R-3 both sides. Common ceiling & floors R-11. EnergyGaugeTm DCA Form 60OA-97 EnergyGauge®/FlaRES'97 FLRCNA-200 I I ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE SCORE* = 84.1 The higher the score, the more efficient the home. RICH PROPERTIES,, PORT ST LUCIE, FL, 1. New construction or existing New _ 12. Cooling systems 2; Single family or multi -family Multi -family _ a. Central Unit Cap: 21.5 kBtu/hr _ 3. Number of units, if multi -family 1 _ SEER: 10.00 _ 4. Number of Bedrooms 1 _ b. N/A 5. Is this a worst case? Yes 6. Conditioned floor area (ft) fi7kft c. N/A _ 7. Glass area & type a. Clear - single pane 54.0 ft2 _ 13. Heating systems b. Clear - double pane 0.0 ft2 _ a. Electric Strip Cap: 17.0 kBtu/hr _ c. Tint/other SC/SHGC - single pane 0.0 ft2 _ COP: 1.00 _ d. Tint/other SC/SHGC - double pane 0.0 ft2 b. N/A _ 8, Floor types _ — a. Slab -On -Grade Edge Insulation R=0.0, 98.0(p) ft _ c. N/A _ b. N/A _ — c. N/A 14. Hot water systems' 9. Wall types _ a. Electric Resistance Cap: 30.0 gallons _ a. Concrete, Int Insul, Exterior R=3.0, 450.0 ft2 _ EF: 0.89 _ b. Concrete, Int Insul, Adjacent R=3.0, 304.5 ft2 _ b. N/A _ c. N/A _ d. N/A _ c. Conservation credits e. N/A (HR-Heat recovery, Solar 10. Ceiling types _ DHP-Dedicated heat pump) a. N/A _ 15. HVAC credits b. N/A _ (CF-Ceiling fan, CV -Cross ventilation, c. N/A HF-Whole house fan, 11. Ducts _ PT -Programmable Thermostat, a. Sup: Con. Ret:.Con. AH: Interior Sup. R=4.2, 30.0 ft _ RB-Attic radiant barrier, b. N/A MZ-C-Multizone cooling, MZ-H-Multizone heating) I certify that this home has complied with the Florida Energy Efficiency Code For Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature: Date: Address of New Home: City/FL Zip: .TIiE ST,91�0�� a �01) WF �&o *NOTE: The home's estimated energy performance score is only available through the FLARES computer program. This is not a Building Energy Rating. If your score is 80 or greater (or 86 for a US EPADOE EnergyStar7mdesignation), your home may qualify for energy efficiency mortgage (EEM incentives if you obtain a Florida Energy Gauge Rating. Contact the Energy Gauge Hotline at 4071638-1492 or see the Energy Gauge web site at www.fsec. ucf edu for information and a list of certified Raters. For information about Florida's Energy Efficiency Code For Building Construction, contact the Department of Community Affairs at 8501487-1824. Energy.Gauge® (Version: FLRCNA-200) RIGHT-J LOAD AND EQUIPMENT SUMMARY, Entire House FES, INC. Job: 01089 4121199 34 N.W. 168TH. STREET, NORTH MIAMI BEACH, FL 33169 Phone: 305-653-0212 Fax: 305-653-0232 Project Information For: SAVANNA CLUB FLAN Al LYP_., F= Phone: WC=e Notes: Design Information Weather: Fort Lauderdale, FL, US Winter Design Conditions Summer Design Conditions Outside db 46 OF Outside db 91 OF Inside db 71 OF Inside db 75 OF Design TD 25 OF Design TD 16 OF Daily range M Relative humidity 50 % Moisture difference 60 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Building heat loss 10251 Btuh Structure 8489 Btuh Ventilation air 0 cfm Ventilation 1320 Btuh Ventilation air loss 0 Btuh Design temperature swing 3.0 OF Design heat load 10251 Btuh Use mfg. data n Rate/swing multiplier 0.96 Infiltration Total sens. equip. load 9416 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Internal gains 460 Btuh Ventilation 3048 Btuh Hea ing�—Cooling �8'94 Infiltration 2730 Btuh Area (ftz) 894� Total latent equip. load 6239 Btuh Volume (ft') 8046 8046 Air changes/hour 1.2 0.5 Total equipment load 15655 Btuh Equiv. AVF (cfm) 161 67 Heating Equipment Summary Cooling Equipment Summary Make n/a Make Trade Trade " n/a Efficiency 100.0 EFF Efficiency 0.0 EER - Heating input 0 Btuh Sensible cooling 0 Btuh Heating output 0 Btuh Latent cooling 0 Btuh Heating temp rise 0 OF Total cooling 0 Btuh Actual heating fan 367 cfm Actual cooling fan 367 cfm Heating air flow factor 0.036 cfm/Btuh Cooling air flow factor 0.043 cfm/Btuh Space thermostat Load sensible heat ratio 61 % Printout certified by ACCA to meet all requirements of Manual J 7th Ed. wng f-titsoft Right-Sulte Residential^" 5.0.45 RSR23656 2001-Jul-05 09:06:44 ACCK H:1Wrightsoft LOAD CALCS\SAVANNA CLUB\PLAN Al BOT.rsr Page 1 RIGHT-J CALCULATION PROCEDURES A, B, C, D 0 Entire House FES, INC. Job: 01089 4121199 34 N.W. 168TH. STREET, NORTH MIAMI BEACH, FL 33169 Phone: 305-653-0212 Fax: 305-653-0232 Procedure A - Winter Infiltration HTM Calculation* 1. Winter infiltration AVF 1.2 ach x 8046 ft3 x 0.0167 = 161 cfm 2. Winter infiltration load 1.1 x 161 cfm x 25 OF Winter TD = 4434 Btuh 3. Winter infiltration HTM 4434 Btuh / 75 ft2 Total window = 59.1 Btuh/ft2 and door area Procedure B - Summer Infiltration HTM Calculation 1. Summer infiltration AVF 0.5 ach x 8046 ft3 x 0.0167 = 67 cfm 2. Summer infiltration load 1.1 x67 cfm x 16 OF SummerTD = 1182 Btuh 3. Summer infiltration HTM 1182 Btuh / 75 ft2 Total window = 15.8 Btuh/ft2 and door area Procedure C - Latent Infiltration Gain 0.68 x60 gr/lb moist.diiff. x 67 cfm = 2730 Btuh eroceaure u - tgwpment sizing Loaas 1. Sensible sizing load Sensible ventilation load 1.1 x 75 cfm vent. x 16 OF Summer TD = 1320 Btuh Sensible load for structure (Line 19) + 8489 Btuh Sum of ventilation and structure loads = 9809 Btuh Rating and temperature swing multiplier x 0.96 Equipment sizing load - sensible = 9416 Btuh 2. Latent sizing load Latent ventilation load 0.68 x 75 cfm vent. x 60 gr/lb moist.diff. = w 3048 Btuh Internal loads = 230 Btuh x 2 people + 460 Btuh Infiltration load from Procedure C + 2730 Btuh Equipment sizing load - latent = 6239 Btuh *Construction Quality is: a No. of Fireplaces is: 0 Bold/italic values have been manually overridden Printout certified by ACCA to meet all requirements of Manual J 7th Ed. , = wnghtsoft Right-SuiteResiderdialTM 5.0.45RSR23656 2001-Jul-0509:06:44 H:\Wrightsoft LOAD CALCS\SAVANNA CLUB\PLAN Al BOT.rsr Page 1 0) co cm 0 C 0 �7 IMIli HIM Mill 0 o •« Zvi o O W0Moo0 0)00 rntnnOoo 00000O 000000 � 00000)0000)r- •♦ i i« {z� •y X W W n T W W W m M L U i • i t ♦ ♦« V' O my r O O O O O N O O O N W 0 0 0 0 0 0 0 0 0 t0 0 0 0 o 0 v O O O r n mWW� isj r $ $ �S N ry rn v o co a) am)� x « «L « s . «SiiSS: Q X M Z 0 n COO 00 V 0 0 0 0 0 n 0 n 0 0 0 0 0 O V to 0 0 O 0 0 0 0 0 0 W 0 0 0 0 0 to o N r c J n W N p st N to to O v co 0) n O O O z W)QMOOO WOO nt0 fh000 OOOOOO 000000 N oO W 000W n D) O W 0) Q) W cOO N ' r vcc ) W W •«` « « 7 m r 0 0 0 0 0 N O O O N W 0 0 0 0 0 0 0 0 0 tp 0 0 0 0 0 `7 O O O r n O W 'O }x ss p {s� j ty$ N �.N-•'MV Do W M N N O«« * j N 70 J x i i 1 «« N n c000O na I- 000 00 Ovtn 000 000000 WO0000 to o Nr o • nWN 300000 V N to WO 0) n O OO v W W W O O O W O W 0 0 0 O 0 0 OR OR W RR 0 r 0 0 0 0 0 O N 0 0 0 0 W 0 0 O) rr 0r 00 « « « « « « rCOGOC 01r0 r r G-GO N00000 ONOC 00 tl') MN �O N Goc r r O x W (D c)vO)00 rr 0000 to 00 W M"t0)00 M00000 Mc00o00 r C O) M cV rC C G NN O C O C O cd N— 00 0 r 00 O O C N V 0 0 0 0 0 } J EL fA0 [aUZU �NMM cD cd ❑Q 00 cv0ZU vNMM ❑ W �Q N0) c6 c LZ cA-5 D7 N + O._ W 3 0 UZ rrr rW ZZ Eo rr rrrr r +. C aoi n� c WM U'D Q Cc U•O 0)u-. ma C.)W.0 0,00- W.0 U'D 0 W.0U•O mw .p y O•@ a LLQ �•� r.V.. CD nIS y 0 co •l0 O C om .0 p+j rnCO � c QOO! Jg2 W � O .o E $ �� ai Li = zov O o mo v m O p 0rE a N WO a. a C am5 Om= • L cSo. ' jrnx j O O ZC. 200CN LL!�C QJJ❑ZJQU g `- 3DX1 (aQ S cAJJ ❑�--Q C9WcC- T co 0) O N M v to W n c0 0) 0 FORM 60OA-97 FLORIDA_ENERGY EFFICIENCY CODE POR BUILDING CONSTRUCTION Florida Department of Community Affairs Residential Whole Building Performance Method A Project Name: SAVANA CLUB APTPAIT;A2=B0T.1 Builder: Address: Permitting Office: PcR'r vr--<uc►e City, State: PORT ST LUCIE, FL Permit Number: Owner: RICH PROPERTIES Jurisdiction Number: 6 6/Roo Climate Zone: Central 1. New construction or existing New _ 12. Cooling systems 2. Single family or multi -family Multi -family _ a. Central Unit 3. Number of units, if multi -family 1 _ 4. Number of Bedrooms 1 _ b. N/A 5. Is this a worst case? Yes _ 6. Conditioned floor area (ft2) 914 ft2 c. N/A 7. Glass area & type a. Clear - single pane 54.0 ft2 _ 13. Heating systems - b. Clear - double pane 0.0 ft2 _ a. Electric Strip ' c. Tintlother SC/SHGC - single pane 0.0 ft2 _ d. Tintlother SC/SHGC - double pane 0.0 ft2 b. N/A S. Floor types _ a. Slab -On -Grade Edge Insulation R=0.0, 46.0(p) ft _ c. N/A b. N/A _ c. N/A 14. Hot water systems 9. Wall types _ a. Electric Resistance a. Concrete, Int Insul, Exterior R=3.0, 450.0 ft2 _ b. Concrete, Int Insul, Adjacent R=3.0, 289.0 ft2 _ b. N/A c. N/A _ d. N/A _ c. Conservation credits e. N/A (HR-Heat recovery, Solar 10. Ceiling types _ DHP-Dedicated heat pump) a. N/A _ 15. HVAC credits b. N/A _ (CF-Ceiling fan, CV -Cross ventilation, c. N/A HF-Whole house fan, 11. Ducts _ PT -Programmable Thermostat, a. Sup: Con. Ret: Con. AH: Interior Sup. R=4.2, 40.0 ft _ RB-Attic radiant barrier, b. N/A MZ-C-Multizone cooling, MZ-H-Multizone heating) Glass/Floor Area: 0.06 Total gas -built points: 9994.90 Total base points: 11677.00 PASS I hereby certify that the plans and specifications covered by this calculation are in compliance with the Florida Energy Code. PREPARED BY: AlLcrt !NC - DATE: Spa/ I hereby certify that this building, as designed, is in compliance with the Florida, E'n y gpfle. OWNER/AGENT: DATE: Cap: 21.9 kBtu/hr _ SEER: 10.00 Cap: 17.0 kBtu/hr _ COP: 1.00 Cap: 30.0 gallons EF: 0.89 lReview of the plans and z sT specifications covered by thisaT�o '. A� calculation indicates compliance y,,,`'''' _ with the Florida Energy Code. Before construction is completed this building will be inspected for compliance with Section 553.908 �•�on� Florida Statutes. WE BUILDING OFFICIAL: DATE: EnergyGauge® (Version: FLRCNA-200) FORM 60OA-97 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Community Affairs Residential Whole Building Performance Method A Project Name: SAVANA CLUB APUNIT A2=BOT] Builder: Address: Permitting Office: City, State: PORT ST LUCIE, FL Permit Number: Owner: RICH PROPERTIES Jurisdiction Number: Climate Zone: Central 1. New construction or existing New _ 12. Cooling systems 2. Single family or multi -family Multi -family _ a. Central Unit 3. Number of units, if multi -family 1 _ 4. Number of Bedrooms 1 _ b. N/A 5. Is this a worst case? Yes _ 6. Conditioned floor area (ft2) C914V c. N/A 7. Glass area & type _ a. Clear - single pane 54.0 ft2 _ 13. Heating systems b. Clear - double pane 0.0 ft2 _ a. Electric Strip c. Tint/other SC/SHGC - single pane 0.0 ft2 _ d. Tintlother SC/SHGC - double pane 0.0 ft2 b. N/A 8. Floor types _ a. Slab -On -Grade Edge Insulation R=0.0, 46.0(p) ft _ c. N/A b. N/A c. N/A 14. Hot water systems 9. Wall types _ a. Electric Resistance a. Concrete, Int Insul, Exterior R=3.0, 450.0 ft2 _ b. Concrete, Int Insul, Adjacent R=3.0, 289.0 ft2 _ b. N/A c. N/A d. N/A _ c. Conservation credits e. N/A (HR-Heat recovery, Solar 10. Ceiling types _ DHP-Dedicated heat pump) a. N/A _ 15. HVAC credits b. N/A _ (CF-Ceiling fan, CV -Cross ventilation, c. N/A HF-Whole house fan, 11. Ducts _ PT -Programmable Thermostat, a. Sup: Con. Ret: Con. AH: Interior Sup. R=4.2, 40.0 ft _ RB-Attic radiant barrier, b. N/A MZ-C-Multizone cooling, MZ-H-Multizone heating) a Glass/Floor Area: 0.06 Total as -built points: 9994.90 PASS Total base points: 11677.00 I hereby certify that the plans and specifications covered by this calculation are in compliance with the Florida Energy Code. PREPARED BY: 410't qL4 F .9 IAVc- DATE: :5 a I hereby certify that this building, as designed, is in compliance with the Florida !Enqpgy ode. OWNER/AGENT: DATE: Cap: 21.9 kBtu/hr SEER: 10.00 Cap: 17.0 kBtu/hr _ COP: 1.00 Cap: 30.0 gallons _ EF: 0.89 Review of the plans and CTUE STAY specifications covered by this calculation indicates compliance with the Florida Energy Code. Before construction is completed A. this building will be inspected for compliance with Section 553.908 �•oon�5'� Florida Statutes. eve BUILDING OFFICIAL: DATE: EnergyGauge® (Version: FLRCNA-200) FORM 60OA-97 SUMMER CALCULATIONS Residential Whole Building Performance Method A - Details ADDRESS:, PORT ST LUCIE, FL, PERMIT #: BASE AS -BUILT GLASS TYPES .18 X Conditioned X BSPM = Points • Overhang Floor Area Type/SC Ornt Len Hgt Area X SPM X SOF = Points .18 914.0 42.08 6922.6 Single, Clear E 2.0 5.0 27.0 59.31 0.81 1290.2 Single, Clear E 2.0 5.0 20.0 59.31 0.81 955.7 Single, Clear S 2.0 3.0 7.0 44.66 0.63 197.1 As -Built Total: 54.0 2443.1 WALL TYPES Area X BSPM = Points Type R-Value Area X SPM = Points Adajcent 289.0 0.7 202.3 Concrete, Int Insul, Exterior 3.0 450.0 1.40 630.0. .Exterior 450.0 1.90 855.0 Concrete, Int Insul, Adjacent 3.0 289.0 0.70 202.3 Base Total: 739.0 1057.3 As -Built Total: 739.0 832.3 DOOR TYPES Area X BSPM = Points Type Area X SPM = Points Adjacent 21.0 1.60 33.6 Adjacent Wood 21.0 2.40 50.4 Exterior 0.0 0.00 0.0 Base Total: 21.0 33.6 As -Built Total: 21.0 50.4 CEILING TYPES Area X BSPM = Points Type R-Value Area X SPM = Points Under Attic 0.0 0.00 0.0 Base Total: 0.0 0.0 As -Built Total: 0.0 0.0 FLOOR TYPES Area X BSPM = Points Type R-Value Area X SPM = Points Slab 46.0(p) -31.8 -1462.8 Slab -On -Grade Edge Insulation 0.0 46.0(p) -31.90 -1467.4 Raised 0.0 0.00 0.0 Base Total: -1462.8 As -Built Total: -1467.4 FNFILTRATION Area X BSPM = Points Area X SPM = Points 914.0 14.31 13079.3 914.0 14.31 13079.3 Summer Base Points: 19630.0 Summer As -Built Points: 14937.7 Total Summer X System = Cooling Total X Cap X Duct X System X Credit = Cooling Points Multiplier Points Component Ratio Multiplier Multiplier Multiplier Points 14937.7 1.000 1 0.930 0.341 1.000 4737.2 19630.0 0.3577 7021.7 14937.7 1.00 0.930 0.341 1.000 4737.2 EnergyGaugeTM DCA Form 60OA-97 FORM 60OA-97 WINTER CALCULATIONS Residential Whole Building Performance Method A - Details ADDRESS:, PORT ST LUCIE, FL, PERMIT #: BASE AS -BUILT GLASS TYPES .18 X Conditioned X BWPM = Points, Overhang Floor Area Type/SC Ornt Len Hgt Area X WPM X WOF = Points 18 914.0 4.79 788.0 Single, Clear E 2.0 5.0 27.0 9.96 1.04 280.3 Single, Clear E 2.0 5.0 20.0 9.96 1.04 207.6 Single, Clear S 2.0 3.0 7.0 7.73 1.51 81.8 As -Built Total: 64.0 569.7 WALL TYPES Area X BWPM = Points Type R-Value Area X WPM = Points Adajcent 289.0 1.8 520.2 Concrete, Int Insul, Exterior 3.0 450.0 3.80 1710.0 Exterior 450.0 2.00 900.0 Concrete, Int Insul, Adjacent 3.0 289.0 2.30 664.7 Base Total: 739.0 1420.2 As -Built Total: 739.0 2374.7 DOOR TYPES Area X BWPM = Points Type Area X WPM = Points Adjacent 21.0 4.00 84.0 Adjacent Wood 21.0 5.90 123.9 Exterior 0.0 0.00 0.0 Base Total: 21.0 84.0 As -Built Total: 21.0 123.9 CEILING TYPES Area X BWPM = Points Type R-Value Area X WPM = Points Under Attic 0.0 0.00 0.0 Base Total: 0.0 0.0 As -Built Total: 0.0 0.0 FLOOR TYPES Area X BWPM = Points Type R-Value Area X WPM = Points Slab 46.0(p) -1.9 -87.4 Slab -On -Grade Edge Insulation 0.0 46.0(p) 2.50 115.0 Raised 0.0 0.00 0.0 Base Total: -87.4 As -Built Total: 115.0 ;NFILTRATION Area X BWPM = Points Area X WPM = Points 914.0 -0.28 -255.9 914.0 -0.28 -255.9 Winter Base Points: 1948.9 Winter As -Built Points: 2927.4 Total Winter X System = Heating Total X Cap X Duct X System X Credit = Heating Points Multiplier Points Component Ratio Multiplier Multiplier Multiplier Points 2927.4 1.000 0.930 1.000 1.000 2722.5 1948.9 1.0730 2091.1 2927.4 1.00 0.930 1.000 1.000 2722.5 EnergyGaugeTm DCA Form 60OA-97 FORM 60OA-97 WATER HEATING & CODE__ COMPLIANCE STATUS Residential Whole Building Performance Method A - Details ADDRESS:, PORT ST LUCIE, FL, PERMIT #: BASE AS -BUILT WATER HEATING Number of X Multiplier = Total Tank EF Number of X Tank X Multiplier X Credit = Total Bedrooms Volume Bedrooms Ratio Multiplier 1 2564.00 2564.0 30.0 0.89 1 1.00 2535.19 1.00 2535.2 As -Built Total: 2535.2 CODE COMPLIANCE STATUS BASE AS -BUILT Cooling + Heating + Hot Water = Total Points Points Points Points 7021.7 2091.1 2564.0 11676.8 4737.2 2722.5 2535.2 9994.9 PASS q" 01JOE ST9?�0�� I a .r,�coD WE���� EnergyGaugeTTM DCA Form 60OA-97 FORM 60OA-97 _Code Compliance Checklist _ Residential Whole Building Performance Method A - Details ADDRESS:, PORT ST LUCIE, FL, PERMIT #: 6A-21 INFILTRATION REDUCTION COMPLIANCE CHECKLIST COMPONENTS SECTION REQUIREMENTS FOR EACH PRACTICE CHECK Exterior Windows & Doors 606.1.ABC.1.1 Maximum:.3 cfm/s .ft. window area; .5 cfm/s .ft. door area. Exterior & Adjacent Walls 606.1.ABC.1.2.1 foundation & wall sole or sill plate; joints between exterior wall panels at comers; utility penetrations; between wall panels & top/bottom plates; between walls and floor. from, and is sealed to, the foundation to the top plate. Floors 606.1.ABC.1.2.2 Penetrations/openings >1/8" sealed unless backed by truss or joint members. EXCEPTION: Frame floors where a continuous infiltration barder.is installed that is sealed to the perimeter, Penetrations and seams. Ceilings 606.1.ABC.1.2.3 Between walls & ceilings; penetrations of ceiling plane of top floor, around shafts, chases, soffits, chimneys, cabinets sealed to continuous air barrier; gaps in gyp board & top plate; installed that is sealed at the perimeter, at penetrations and seams. Recessed Lighting Fixtures 606.1.ABC.1.2.4 conditioned space, tested. Multi -story Houses 606.1.ABC.1.2.5 Air barrier on perimeter of floor cavity between floors. Additional Infiltration reqts 606.1.ABC.1.3 have combustion air. RA-99 (ATI41=R PRESCRIPTIVE MFASI IRFS fmnct ha mat nr pxr_pprlpcl by all rPsidpnr_Ps_1 COMPONENTS SECTION REQUIREMENTS CHECK Water Heaters 612.1 breaker electric or cutoff as must be provided. External or built-in heat trap required. Swimming Pools & Spas 612.1 must have a pump timer. Gas spa & pool heaters must have a minimum thermal efficiency of 78%. Shower heads 612.1 Water flow must be restricted to no more than 2.5 gallons per minute at 80 PSIG. Air Distribution Systems 610.1 attached, sealed, insulated, and installed in accordance with the criteria of Section 610. Ducts in unconditioned attics: R-6 min. insulation. HVAC Controls 607.1 Separate readily accessible manual or automatic thermostat for each system. Insulation 604.1, 602.1 Ceilings -Min. R-19. Common walls -Frame R-11 or CBS R-3 both sides. Common ceiling & floors R-11. EnergyGaugeTM DCA Form 60OA-97 EnergyGauge®/FlaRES'97 FLRCNA-200 DISPLAY CARD ESTIMATED ENERGY PERFORMANCE SCORE* = 84.6 The higher the score, the more efficient the home. 1. New construction or existing .2. Single family or multi -family 3. Number of units, if multi -family 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned floor area (ft2) 7. Glass area & type a. Clear - single pane • b. Clear - double pane c. Tintlother SC/SHGC - single pane d. Tintlother SC/SHGC - double pane '8. Floor types a. Slab -On -Grade Edge Insulation b. N/A c. N/A 9. Wall types a. Concrete, Int Insul, Exterior b. Concrete, Int Insul, Adjacent c. N/A d. N/A e. N/A 10. Ceiling types a. N/A b. N/A c. N/A 11. Ducts a. Sup: Con. Ret: Con. AH: Interior b. N/A RICH PROPERTIES,, PORT ST LUCIE, FL, New _ 12. Cooling systems Multi -family _ a. Central Unit 1 1 _ b. N/A Yes _ 914 ftZ c. N/A 54.0 ft2 _ 13. Heating systems 0.0 ft2 _ a. Electric Strip 0.0 ft2 _ 0.0 ft2 b. N/A R=0.0, 46.0(p) ft _ c. N/A 14. Hot water systems _ a. Electric Resistance R=3.0, 450.0 ft2 R=3.0, 289.0 ft2 _ b. N/A _ c. Conservation credits (HR-Heat recovery, Solar _ DHP-Dedicated heat pump) _ 15. HVAC credits _ (CF-Ceiling fan, CV -Cross ventilation, HF-Whole house fan, _ PT -Programmable Thermostat, Sup. R=4.2, 40.0 ft _ RB-Attic radiant barrier, MZ-C-Multizone cooling, MZ-H-Multizone heating) I certify that this home has complied with the Florida Energy Efficiency Code For Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed .based on installed Code compliant features. Builder Signature: Address of New Home: Date: City/FL Zip: Cap: 21.9 kBtu/hr _ SEER: 10.00 Cap: 17.0 kBtu/hr _ COP: 1.00 Cap: 30.0 gallons _ EF: 0.89 _ *NOTE. The home's estimated energy performance score is only available through the FLARES computer program. TM your home may qualify for energy efficiency mortgage (EEM incentives if you obtain a Florida Energy Gauge Rating. Contact the Energy Gauge Hotline at 4071638-1492 or see the Energy Gauge web site at www.fsec. ucf edu for information and a list of certified Raters. For information about Florida's Energy Efficiency Code For Building Construction, contact the Department of Community Affairs at 8501487-1824. EnergyGaugeO (Version: FLRCNA-200) RIGHT-J LOAD AND EQUIPMENT SUMMARY Entire House FES, INC. Job: SAVANA CLUB UNIT A2-130T 4/21199 34 N.W. 168TH. STREET, NORTH MIAMI BEACH, FL 33169 Phone: 305-653-0212 Fax: 305-653-0232 Project• • For: SAVANNA CLUB UNIT�A2=BOT; F`L' Phone:-WC--W Notes: SAVANA CLUB UNIT A2-BOT Weather: Winter Design Conditions Outside db 47 OF Inside db 71 OF Design TD 24 OF Heating Summary Building heat loss 11406 Btuh Ventilation air 0 cfm Ventilation air loss 0 Btu Design heat load 11406 Btu Infiltration Method Simplified Construction quality Average Fireplaces 0 West Palm Beach, FL, US Summer Design Conditions h h Outside db 90 OF Inside db 75 OF Design TD 15 OF Daily range L Relative humidity 50 % Moisture difference 61 gr/lb Sensible Cooling Equipment Load Sizing Structure 10820 Btuh. Ventilation 825 Btuh Design temperature swing 3.0 OF Use mfg. data n Rate/swing multiplier 0.95 Total sens. equip. load 11063 Btuh Heating Cooling Area (ft2) 914 914 Volume (ft') 8226 8226 Air changes/hour 1.0 0.5 Equiv. AVF (cfm) 137 69 Heating Equipment Summary Make n/a Trade n/a Efficiency • Heating input Heating output Heating temp rise Actual heating fan Heating air flow factor Space thermostat 0 Btuh 0 Btuh 0 OF 468 cfm 0.041 cfm/Btuh Latent Cooling Equipment Load Sizing Internal gains 460 Btuh Ventilation 2088 Btuh Infiltration 2868 Btuh Total latent equip. load 5416 Btuh Total equipment load 16479 Btuh Cooling Equipment Summary Make Trade Efficiency 0.0 EER Sensible cooling 0 Btuh Latent cooling 0 Btuh Total cooling 0 Btuh Actual cooling fan 468 cfm Cooling air flow factor 0.043 cfm/Btuh Load sensible heat ratio 68 % Printout certified by ACCA to meet all requirements of Manual J 7th Ed. �- Wrj0h t50ft Right -Suite Residentl;Iw 5.0.58 RSR23656 2001-Oct-10 11:55:02 /4CC% H:IWrightsoft LOAD CALCSISAVANNA CLUBIPLAN A2 BOT.rsr Page 1 RIGHT-J SHORT FORM Entire House -- - ` FES, INC. Job: SAVANA CLUB UNIT A2-130T 4121/99 34 N.W. 168TH. STREET, NORTH MIAMI BEACH, FL 33169 Phone: 305-653-0212 Fax: 305 65M232 Project• • For: SAVANNA-CL-UBi I�IT A2-BOT.; FL Phone: WC-=W� Design Information Htg Clg Infiltration Outside db (°F) 47 90 Method Simplified Inside db (°F) 71 75 Construction quality Average Design TD (OF) 24 15 Fireplaces 0 Daily range - L Inside humidity (%) - 50 Moisture difference (gr/lb) - 61' HEATING EQUIPMENT COOLING EQUIPMENT Make n/a Make Trade Trade n/a Efficiency 100.0 EFF Efficiency 0.0 EER Heating input 0 Btuh Sensible cooling 0 Btuh Heating output 0 Btuh Latent cooling 0 Btuh Heating temperature rise 0 OF Total cooling 0 Btuh Actual heating fan 468 cfm Actual cooling fan 468 cfm Heating air flow factor 0.041 cfm/Btuh Cooling air flow factor 0.043 cfm/Btuh Space thermostat Load sensible heat ratio 68 % ROOM NAME Area Htg load Clg load Htg AVF Clg AVF (ft2) (Btuh) (Btuh) (cfm) (cfm) UNIT-A2-130T 914 11406 10820 468 468 Entire House d 914 11406 10820 468 468 Ventilation air 0 825 Equip. @ 0.95 RSM 11063 Latent cooling 5416 Tyrw. r. I nAA 44Ann 4MA70 AAR AAR Printout certified by ACCA to meet all requirements of Manual J 7th Ed. wrightsoft Right -Suite Residential^" 5.0.58 RSR23656 2001-Oct-10 11:55:02 ,(gip H:\Wrightsoft LOAD CALCS\SAVANNA CWB\PLAN A2 BOT.rsr Page 1 OP `�.O. a W �5r 00 Dp 0 W Ito to D.. Cl) C C) C; at CD N !D a �CD z� to Oo 1 it, co N (0)) rn 0 co V T CA X� A W N> D—I�rrin �orrtn j �p N�'�T O N Z 0 Z w x O S o $ m �03 X � Ci.Z1� Z (D w N N (O N tyI) i o y p CD .O. y O N 7 N n _� w 7 c. N n .%='p O y N p O 0 N N .p-. 7• .O+ N y (D (D N 7 3 y C y O m y f0 3 Cl) y Z C •ch p x N O N C7 y N7 7 7 Q N n On 0 0 O y 0 0 O.N >> n Nn C C-n a O �. C O'O -0 3 N y 7 N m j X r O N= �' w N n n O w 7 w �+ 3 �- 8 + N+ _ CD v H E"r "^N C10 O'w ^`N nt�O'w �O n0 O'w O vw '*fD O.O vw �`fD L10 o•w r.� A .w.m n zn 3� m o``O) a� oq mm vPTCb-• D� o CA to NA czcm 00 Do ayZc C � z WNA ozow O( 7 0 N N = @ + N O T 03 0 0 0 0 A co 0 0 0 0 0> 0 0 0> N W G O W A N fJ1 O W> O ?. G P O O P P P 0 0 0 0 0 0 O> N W C O tO A 1J fT p OO _ OOOON O OOOOON 00-+>NN > O NO m N OOO�O n ' 00 OOOOODO 00000 W OOW OIJ O V A 000000 00 W� ON ?S y 2) 7 0 o O V f0 o N A t0 to W CA Cn co w C oss o 01 OOOO O O OOOOOO O OOO A O OO OOO O O CT OO OOOA O Os O*S> V (p �}7 +�>N i 7 f0 CD A► i i i A A 0) .A.i >_ Of N W n .00D O O co O O 0)0 O O O) N V O O OOO A O O O O O O O CT OOO V V G) coN O O N O OOOOA C i $} }S 0v Am 003 NCD •-' n j.�fD W W n m O O O O Ot O O W O O O O O O O 0 0 0 O O OOO W 0 O O co O OO m 0 CD # ; i i 3 � C . 0 V w c o z 0 O V W o OO OOO O OOO o00 CID Cn CA O 000 A O N OO N W OOOOOOt to OOOOOA -W+ O OSsO O» V O 71 S (0 C' c pai co W DO) n co O O � co 0 000 0)V 000 OA O 0 00000 O 000 V V C)) -0OOOOA O O i O NCA j> O j W W s ••♦ co 000 n 0s00 W 000000 000000 > f0 000 W O> 00 W W co OOPCDO w s z S S S i 5 y ii d O C4 CD cn CP n,;u m �— ^Z^ —4 `I 0 L 5N� 00T Vi i 2 m i FORM 60OA-97 FLORIDA EN_ ERGY EFFICIENCY -.CODE FOR BUILDING CONSTRUCTION Florida Department of Community Affairs Residential Whole Building Performance Method A .Project Name: SAVANNA CLUB PLAN Al TO - Builder: 'Address: Permitting Office: FORT sT c.vcle City,'State: PORT ST LUCIE, FL Permit Number: Owner: RICH PROPERTIES Jurisdiction Number: 6CI200 Climate Zone: Central 1. New construction or existing New _ 12. Cooling systems - 2. Single family or multi -family Multi -family _ a. Central Unit 3. Number of units, if multi -family 1 - 4. Number of Bedrooms 1 _ b. N/A 5. Is this a worst case? Yes 6. Conditioned floor area (ft2) _ 899_ 2 . c. N/A 7. Glass area & type _ a. Clear - single pane 54.0 ft2 _ 13. Heating systems b. Clear - double pane 0.0 ft2 _ a. Electric Strip c. Tint/other SC/SHGC - single pane 0.0 ft2 _ d. Tintlother SC/SHGC - double pane 0.0 ft2 b. N/A 8. Floor types _ a. Slab -On -Grade Edge Insulation R=0.0, 98.0(p) ft _ c. N/A b. N/A _ c. N/A 14. Hot water systems 9. Wall types _ a. Electric Resistance a. Concrete, Int Insul, Exterior R=3.0, 450.0 ft2 b. Concrete, Int Insul, Adjacent R=3.0, 304.5 ft2 _ b. N/A c. N/A _ d. N/A _ c. Conservation credits e. N/A (HR-Heat recovery, Solar 10. Ceiling types _ DHP-Dedicated heat pump) a. Under Attic R=19.0, 894.0 ft2 _ 15. HVAC credits b. N/A _ (CF-Ceiling fan, CV -Cross ventilation, c. N/A HF-Whole house fan, 11. Ducts _ PT -Programmable Thermostat, a. Sup: Con. Ret: Con. AH: Interior Sup. R=4.2, 30.0 ft _ RB-Attic radiant barrier, b. N/A MZ-C-Multizone cooling, MZ-H-Multizone heating) Glass/Floor Area: 0.06 Total as -built points: 10811.00 y PASS Total base points:,11611.00 I. hereby certify that the plans and specifications covered by this calculation are in compliance with the Florida 'Energy Code. PREPARED BY: DATE:��% I hereby certify that this building, as des' ned, is in compliance with the Florda En de. OWNERIAGENT: DATE: I9 /i of Cap: 21.5 kBtu/hr _ SEER: 10.00 Cap: 17.0 kBtu/hr _ COP: 1.00 Cap: 30.0 gallons EF: 0.89 Review of the plans and zOE Sr aT�o specifications covered by this indicates tio�` = calculation compliance�•��D� with the Florida Energy Code. Before construction is completed A' ""� "" ° °� a this building will be inspected for compliance with Section 553.908 �•�oD� Florida Statutes. WF BUILDING OFFICIAL: DATE: EnergyGauge® (Version: FLRCNA-200) 7 9 FORM 60OA-97 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Community Affairs Residential Whole Building Performance Method A Project Name: SAVANNA CLUB PLA ATTOP Builder: Address: Permitting Office: City, State: PORT ST LUCIE, FL Permit Number: Owner: RICH PROPERTIES Jurisdiction Number: Climate Zone: Central 1. New construction or existing New - 12. Cooling systems 2. Single family or multi -family Multi -family - a. Central Unit Cap: 21.5 kBtu/hr - .-3. Number of units, if multi -family 1 _ SEER: 10.00 _ 4. Number of Bedrooms I - b. N/A - 5. Is this a worst case? Yes _ - 6. Conditioned floor area (ft2) 894 $2 c. N/A - 7. Glass area & type - - a. Clear - single pane 54.0 ft2 - 13. Heating systems - b. Clear - double pane 0.0 ft2 - a. Electric Strip Cap: 17.0 kBtu/hr - c. Tint/other SC/SHGC - single pane 0.0 ft2 - COP: 1.00 - d. Tint/other SC/SHGC - double pane 0.0 ft2 b. N/A - -8. Floor types - - a. Slab -On -Grade Edge Insulation R=0.0, 98.0(p) ft - c. N/A - b. N/A - - c. N/A 14. Hot water systems 9. Wall types - a. Electric Resistance Cap: 30.0 gallons - a. Concrete, Int Insul, Exterior R=3.0, 450.0 ft2 - EF: 0.89 - b. Concrete, Int Insul, Adjacent R=3.0, 304.5 ft2 - b. N/A - c. N/A - - d. N/A _ c. Conservation credits - e. N/A (HR-Heat recovery, Solar 10. Ceiling types - DHP-Dedicated heat pump) a. Under Attic R=19.0, 894:0 ft2 - 15. HVAC credits - b. N/A - (CF-Ceiling fan, CV -Cross ventilation, c. N/A HF-Whole house fan, 11. Ducts - PT -Programmable Thermostat, a. Sup: Con. Ret: Con. AH: Interior Sup. R=4.2, 30.0 ft - RB-Attic radiant barrier, b. N/A MZ-C-Multizone cooling, MZ-H-Multizone heating) Glass/Floor Area: 0.06 Total as -built points: 10811.00 PASS Total base points: 11611.00 I hereby certify that the plans and specifications covered by this calculation are in compliance with the Florida Energy Code. PREPARED BY:Alieel XX4 i-'F.S,, Tivc DATE: I hereby certify that this building, as desi ed, is in compliance with the Florida En e C e. OWNER/AGENT: DATE: /D /! i)/ Review of the plans and ST`9�� specifications covered by this indicates o�'JUE ti = , , o �'� calculation compliance with the Florida Energy Code. is Before construction completed a this building will be inspected for compliance with Section 553.908 •con�y� Florida Statutes. BUILDING OFFICIAL: DATE: EnergyGauge® (Version: FLRCNA-200) FORM 60OA-97 SUMMER CALCULATIONS Residential Whole Building Performance Method A - Details ADDRESS: , PORT ST LUCIE, FL, PERMIT #: BASE AS -BUILT GLASS TYPES X Conditioned X BSPM = Points Overhang .18 Floor Area Type/SC Ornt Len Hgt Area X SPM X SOF = Points .18 894.0 42.08 6771.1 Single, Clear E 1.0 5.5 27.0 59.31 0.96 1543.6 Single, Clear E 1.0 5.5 20.0 59.31 0.96 1143.4 Single, Clear S 1.0 4.3 7.0 44.66 0.88 274.5 As -Built Total: 54.0 2961.4 WALL TYPES Area X BSPM = Points Type R-Value Area X SPM = Points Adajcent 304.5 0.7 213.1 Concrete, Int Insul, Exterior 3.0 450.0 1.40 630.0 ' Exterior 450.0 1.90 855.0 Concrete, Int Insul, Adjacent 3.0 304.5 0.70 213.1 Base Total: 754.5 1068.1 As -Built Total: 754.5 843.2 DOOR TYPES Area X BSPM = Points Type Area X SPM = Points Adjacent 21.0 1.60 33.6 Adjacent Wood 21.0 2.40 50.4 Exterior 0.0 0.00 0.0 Base Total: 21.0 33.6 As -Built Total: 21.0 50.4 CEILING TYPES Area X BSPM = Points Type R-Value Area X SPM = Points U'er Attic 894.0 0.60 536.4 Under Attic 19.0 894.0 1.10 983.4 Bag Total: 894.0 636.4 As -Built Total: 894.0 983.4 1 FLLOR TYPES Area X BSPM = Points Type R-Value Area X SPM = Points SI2i;} 98.0(p) -31.8 -3116.4 Slab -On -Grade Edge Insulation 0.0 98.0(p) -31.90 -3126.2 RJ:r 0.0 0.00 0.0 Baotal: -3116.4 As -Built Total: -3126.2 ' IPfRATION Area XBSPM =Points Area X SPM = Points 894.0 14.31 12793.1 894.0 14.31 12793.1 Slier Base Points: 18086.0 Summer As -Built Points: 14505.3 r: dimmer X System = Cooling Total X Cap X Duct X System X Credit = Cooling its Multiplier Points Component Ratio Multiplier Multiplier Multiplier Points ti. 14605.3 1.000 0.930 0.341 1.000 4600.1 I 16.0 0.3577 6469.4 14505.3 1.00 0.930 0.341 1.000 4600.1 4+. 1 1 i�. 6eTM DCA Form 60OA-97 I A I FORM 60OA-97 WINTER CALCULATIONS Residential Whole Building Performance Method A - Details ADDRESS: , PORT ST LUCIE, FL, PERMIT #: BASE AS -BUILT -GLASS TYPES .18 X Conditioned X BWPM = Points • Overhang Floor Area Type/SC Ornt Len Hgt Area X WPM X WOF = Points .18 894.0 4.79 770.7 Single, Clear E 1.0 5.5 27.0 9.96 1.01 271.6 Single, Clear E 1.0 5.5 20.0 9.96 1.01 201.2 Single, Clear S 1.0 4.3 7.0 7.73 1.04 56.5 As -Built Total: 54.0 529.3 WALL TYPES Area X BWPM = Points Type R-Value Area X WPM = Points Adajcent 304.5 1.8 548.1 Concrete, Int Insul, Exterior 3.0 450.0 3.80 1710.0 Exterior 450.0 2.00 900.0 Concrete, Int Insul, Adjacent 3.0 304.5 2.30 700.3 Base Total: 754.5 1448.1 As -Built Total: 754.5 2410.4 DOOR TYPES Area X BWPM = Points Type Area X WPM = Points s Adjacent 21.0 4.00 84.0 Adjacent Wood 21.0 5.90 123.9 Exterior 0.0 0.00 0.0 Base Total: 21.0 84.0 As -Built Total: 21.0 123.9 CEILING TYPES Area X BWPM = Points Type R-Value Area X WPM = Points Under Attic 894.0 0.60 536.4 Under Attic 19.0 894.0 1.00 894.0 Base Total: 894.0 536.4 As -Built Total:. 894.0 894.0 FLOOR TYPES Area X BWPM = Points Type R-Value Area X WPM = Points Slab 98.0(p) -1.9 -186.2 Slab -On -Grade Edge Insulation 0.0 98.0(p) 2.50 245.0 Raised 0.0 0.00 0.0 Base Total: -186.2 As -Built Total: 245.0 INFILTRATION Area X BWPM = Points Area X WPM = Points 894.0 -0.28 -250.3 894.0 -0.28 -250.3 Winter Base Points: 2402.7 Winter As -Built Points: 3952.3 Total Winter X System = Heating Total X Cap X Duct X System X Credit = Heating Points Multiplier Points Component Ratio Multiplier Multiplier Multiplier Points 3952.3 1.000 0.930 1.000 1.000 3675.6 2402.7 1.0730 2578.1 3952.3 1.00 0.930 1.000 1.000 3675.6 EnergyGaugeTm DCA Form 60OA-97 FORM 60OA-97 WATER___ HEATING & CODE_ COMPLIANCE STATUS Residential Whole Building Performance Method A - Details ADDRESS:, PORT ST LUCIE, FL, PERMIT #: BASE AS -BUILT WATER HEATING Number of X Multiplier = Total Tank EF Number of X Tank X Multiplier X Credit = Total Bedrooms Volume Bedrooms Ratio Multiplier 1 2564.00 2564.0 30.0 0.89 1 1.00 2535.19 1.00 2535.2 As -Built Total: 2535.2 CODE COMPLIANCE STATUS BASE AS -BUILT Cooling + Heating + Points Points Hot Water Points = Total Points Cooling Points + Heating + Hot Water = Total Points Points Points 6469.4 2578.1 2564.0 11611.5 4600.1 3675.6 2535.2 10810.9 PASS EnergyGaugeTm DCA Form 60OA-97 FORM 60OA-97 Code Compliance Checklist Residential Whole Building Performance Method A - Details ADDRESS:, PORT ST LUCIE, FL, PERMIT #: 6A-21 INFILTRATION REDUCTION COMPLIANCE CHECKLIST COMPONENTS SECTION REQUIREMENTS FOR EACH PRACTICE CHECK Exterior Windows & Doors 606.1.ABC.1.1 Maximum:.3 cfm/s .ft. window area .5 cfm/s .ft. door area. Exterior & Adjacent Walls 606.1.ABC.1.2.1 Caulk, gasket, weatherstrip or seal between: windows/doors & frames, surrounding wall; foundation & wall sole or sill plate; joints between exterior wall panels at corners; utility penetrations; between wall panels & top/bottom plates; between walls and floor. EXCEPTION: Frame walls where a continuous infiltration barrier is installed that extends from and is sealed to the foundation to the top plate. Floors 606.1.ABC.1.2.2 Penetrations/openings >1/8" sealed unless backed by truss or joint members. EXCEPTION: Frame floors where a continuous infiltration barrier is installed that is sealed to the perimeter, penetrations and seams. Ceilings 606.1.ABC.1.2.3 Between walls & ceilings; penetrations of ceiling plane of top floor; around shafts, chases, soffits, chimneys, cabinets sealed to continuous air barrier; gaps in gyp board & top plate; attic access. EXCEPTION: Frame ceilings where a continuous infiltration barrier is installed that is sealed at the perimeter, at penetrations and seams. Recessed Lighting Fixtures 606.1.ABC.1.2.4 Type IC rated with no penetrations, sealed; or Type IC or non -IC rated, installed inside a sealed box with 1/2" clearance & 3" from insulation; or Type IC rated with < 2.0 cfm from conditioned space, tested. Multi -story Houses 606.1.ABC.1.2.5 Air barrier on perimeter of floor cavity between floors. Additional Infiltration reqts 606.1.ABC.1.3 Exhaust fans vented to outdoors, dampers; combustion space heaters comply with NFPA, have combustion air. CA 99 fVrUC0 130CQf�010711/C RACACI IDCC 1—M- hn mn4 nr nvrnniinri rnv all racirinnePs I COMPONENTS SECTION REQUIREMENTS CHECK Water Heaters 612.1 Comply with efficiency requirements in Table 6-12. Switch or clearly marked circuit breaker electric or cutoff as must be provided. External or built-in heat trap required. Swimming Pools & Spas 612.1 Spas & heated pools must have covers (except solar heated). Non-commercial pools must have a pump timer. Gas spa & pool heaters must have a minimum thermal efficiency of 78%. Shower heads 612.1 Water flow must be restricted to no more than 2.5 gallons per minute at 80 PSIG. Air Distribution Systems 610.1 All ducts, fittings, mechanical equipment and plenum chambers shall be mechanically attached, sealed, insulated, and installed in accordance with the criteria of Section 610. Ducts in unconditioned attics: R-6 min. insulation. HVAC Controls 607.1 Separate readily accessible manual or automatic thermostat for each system. Insulation 604.1, 602.1 Ceilings -Min. R-19. Common walls -Frame R-11 or CBS R-3 both sides. Common ceiling & floors R-11. EnergyGaugeTM DCA Form 60OA-97 EnergyGauge®/FlaRES'97 FLRCNA-200 a A ,. ENERGY PERFORMANCE LEVEL (EPL) - DISPLAY CARD ESTIMATED ENERGY PERFORMANCE SCORE* = 84.1 The higher the score, the more efficient the home. 1. New construction or existing .2. Single family or multi -family 3. Number of units, if multi -family 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned floor area (ft2) 7. Glass area & type a. Clear - single pane b. Clear - double pane c. Tint/other SC/SHGC - single pane d. Tintlother SC/SHGC - double pane 1. Floor types a. Slab -On -Grade Edge Insulation b. N/A c. N/A 9. Wall types a. Concrete, Int Insul, Exterior b. Concrete, Int Insul, Adjacent c. N/A d. N/A e. N/A 10. Ceiling types a. Under Attic b. N/A c. N/A 11. Ducts a. Sup: Con. Ret: Con. AH: Interior b. N/A RICH PROPERTIES,, PORT ST LUCIE, FL, New _ 12. Cooling systems Multi -family _ a. Central Unit 1 _ 1 _ b. N/A Yes _ 8 4_ft: c. N/A 54.0 ft2 _ 13. Heating systems 0.0 ft2 _ a. Electric Strip 0.0 ft2 _ 0.0 ft2 b. N/A R=0.0, 98.0(p) ft _ c. N/A 14. Hot water systems _ a. Electric Resistance R=3.0, 450.0 ft2 R=3.0, 304.5 ft2 _ b. N/A _ c. Conservation credits (HR-Heat recovery, Solar _ DHP-Dedicated heat pump) R=19.0, 894.0 ft2 _ 15. HVAC credits _ (CF-Ceiling fan, CV -Cross ventilation, HF-Whole house fan, _ PT -Programmable Thermostat, Sup. R=4.2, 30.0 ft _ RB-Attic radiant barrier, MZ-C-Multizone cooling, MZ-H-Multizone heating) I certify that this home has complied with the Florida Energy Efficiency Code For Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature: Address of New Home: Date: City/FL Zip: Cap: 21.5 kBtu/hr _ SEER: 10.00 Cap: 17.0 kBtu/hr _ COP: 1.00 Cap: 30.0 gallons _ EF: 0.89 _ *NOTE: The home's estimated energy performance score is only available through the FLARES computer program. This is not a Building Energy Rating. If your score is 80 or greater (or 86 for a US EPADOE EnergyStardesignation), your home may qualms for energy efficiency mortgage (EEM incentives ifyou obtain a Florida Energy Gauge Rating. Contact the Energy Gauge Hotline at 4071638-1492 or see the Energy Gauge web site at www.fsec. ucf. edu for information and a list of certified Raters. For information about Florida's Energy Efficiency Code For Building Construction, contact the Department of Community Affairs at 8501487-1824. EnergyGauge® (Version: FLRCNA-200) RIGHT-J LOAD AND EQUIPMENT SUMMARY Entire House FES, INC. Job: 01089 4121199 34 N.W. 168TH. STREET, NORTH MIAMI BEACH, FL 33169 Phone: 305-653-0212 Fax: 305-65U232 Project• • For: SAVANNA CLUB PLAN Al TOP FL, FL Phone: WC=e Notes: Design Information Weather: Fort Lauderdale, FL, US Winter. Design Conditions Summer Design Conditions Outside db 46 OF Outside db 91 OF Inside db 71. OF Inside db 75 OF Design TD 25 OF Design TD 16 OF Daily range M Relative humidity 50 % Moisture difference 60 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Building heat loss 9451 Btuh Structure 9934 Btuh Ventilation air 0 cfm Ventilation 880 Btuh Ventilation air loss 0 Btuh 'Design temperature swing 3.0 OF Design heat load 9451 Btuh Use mfg. data n Rate/swing multiplier 0.96 Infiltration Total sens. equip. load 10382 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Internal gains 460 Btuh Ventilation 2032 Btuh Heating Cooling Infiltration 2730 Btuh Area (ft2) (.694 893:� Total latent equip. load 5223 Btuh Volume (fF) 8046 8046 Air changes/hour 1.2 0.5 Total equipment load 15604 Btuh Equiv. AVF (cfm) 161 67 Heating Equipment Summary Cooling Equipment Summary Make n/a Make - Trade Trade n/a Efficiency 100.0 EFF Efficiency 0.0 EER • Heating input 0 Btuh Sensible cooling 0 Btuh Heating output 0 Btuh Latent cooling 0 Btuh Heating temp rise 0 OF Total cooling 0 Btuh Actual heating fan 430 cfm Actual cooling fan 430 cfm Heating air flow factor 0.046 cfm/Btuh Cooling air flow factor 0.043 cfm/Btuh Space thermostat Load sensible heat ratio 67 % Printout certified by ACCA to meet all requirements of Manual J 7th Ed. wng htsoft Right -Suite ResldentialTM 5.0.45 RSR23656 2001-Jul-05 09:11:50 H:ftightsott LOAD CALCS\SAVANNA CLUBIPLAN Al TOP.rsr Page 1 0 O C_ 0 CD CD Q. ^n ♦J D 0 B CD CD SD O 3 (D C N L v N• m a O O W V O Cn A W N •'.� O CO CID V O Cn A W N -+ D�orry g �Orrfn � ^-vim- n (� CD o i X Z w w O osg O w =� Si tD w rt1 v Doi inc � X� m o rz w w E 0 fn Q !n N f0 N .Oi. N N S O y n . O O N W 7 a v O N E. N n C N n fR O N D m 7 O fp ID C.Z1 O y O 0 0 �.. w 0 � C' N 3 w C-i/ D' r ^^ " f0 C O w y 7 7 CD O O O O 7 O O N O w N >> O O S y d o. Z w pj 7 • cn ' N 7 N w N N 7' — O (� O N N n p to p N N n n O C CD n y 3= w II N a y N 3 w 7 m CD X O r 'o w C/, a n N C- + CD + y0. �`(D n0fSw �`CD nO CTw "'CD n000 OVw MCI) �`CD nn Qw "'tD nO tSw p 11 D� A C� 7' m ON co Low N A 0� 3+ f� �'�0�� f0 w m m C j w d vrm Dv O W W NA 0z0co 00 Do a ``, �fCn ZS WW ozom j CD ��11^ G _n = Nla^ r N OOOOAO CD 0000 � 000—N W OAS OOOO D7G) OO o-+N w !n � OOO Ofb W 00000 W 000011 LJO 00 (n 0000-�-� 00 tOA (J !n = p NW n ko 00 o ON 0 00000 N 00� 0 �-+ O-'CO 000 Cn O,�N1 • '� '� • '� '� OO�O--�-� f0 00 OOOONO 00000� 000 mm w 000 000OD ObD 000CD co co y D S: t S � � m O CI O V f00 O Cn (AJ1 W C7t N co V w O = c �N c CA o00000 000OOA o 0o CnAO OO 00000 Cn 000 OOA OOOO) V CD i i CD co ♦ » s CO CO A Z, A4 Cn N S 0. m A 0 0 0 0 0 A 0 0 0 0 o 0 0 0 0 0 0 COn 0 0 0 CA N O O O N 0 0 0 0 0 W C ♦ ♦ + w '»� » i i 92Z ca A coOCOO N O OD V n CA (a W OO O AO o 0A 00 m N 000000 tD 00000 Cn t000 000 V Cn V W 00 CO CD 000 V 00 �io x o, co CA Cn N(A V w r 0 D O O �N O \ V Cn 000000 co 000OOA OCn CAn OOO CnAO 00 000 CO OO, OO o 00A o 00(A V 00 Z S X D }$S$ }z s t0 O w CD (D co 0 C m OL 0 O_A WO -�+000 A 000000 OOOOOCOn 0000 N o OON 00000� ^W • S$ W x i i i S S to v CD (O -+ 10 co" i i 2 Cp co V co co v co W A V A o 0 O A 0 0 N 0 0 0 0 0 0 0 0 0 0 0 M 0 0 0 V Cn 10000 0 0 0 0 0 w d • S � i x � » � i � i i '� f0 52 C- 0 O 0 co Co A N m tD s 0 RIGHT-J CALCULATION PROCEDURES A, B, C, D Entire House FES, INC. Job: 01089 4121199 34 N.W.166TH. STREET, NORTH MIAMI BEACH, FL 33169 Phone: 305-653-0212 Fax: 305-653-0232 Procedure A - Winter Infiltration HTM Calculation* 1. Winter infiltration AVF 1.2 ach x 8046 ft3 x 0.0167 = 161 cfm 2. Winter infiltration load 1.1 x 161 cfm , x 25 OF Winter TD = 4434 Btuh 3. Winter infiltration HTM 4434 Btuh / 75 ft2 Total window = 59.1 Btuh/ftz anddoor area Procedure B - Summer Infiltration HTM Calculation 1. Summer infiltration AVF 0.5 ach x 8046 ft3 x 0.0167 = 67 cfm 2. Summer infiltration load 1.1 x67 cfm x 16 OF Summer TD = 1182 Btuh 3. Summer infiltration HTM 1182 Btuh / 75 ftz Total window = 15.8 Btuh/ft2 and door area Procedure C - Latent Infiltration Gain 0.68 x 60 gr/lb moist.diff. x 67 cfm = 2730 Btuh Procedure u - equipment bizing Loaas 1. Sensible sizing load Sensible ventilation load 1.1 x 50 cfm vent. x 16 OF Summer TD = 880 Btuh Sensible load for structure (Line 19) + 9934 Btuh Sum of ventilation and structure loads = 10814 Btuh Rating and temperature swing multiplier x 0.96 Equipment sizing load - sensible = 10382 Btuh 2. Latent sizing load Latent ventilation load 0.68 x 50 cfm vent. x 60 gr/lb moist.diff. _ 2032 Btuh Internal loads = 230 Btuh x 2 people + 460 Btuh Infiltration load from Procedure C + 2730 Btuh Equipment sizing load - latent = 5223 Btuh *Construction Quality is: a No. of Fireplaces is: 0 Bold/italic values have been manually overridden Printout certified by ACCA to meet all requirements of Manual J 7th Ed. ASF. wino htsoft Right -Suite Residerdialm S.0.45 RSR23656 2001-Jul-05 09:11:50 ACCK HAWrightsoft LOAD CALCSISAVANNA CLUBTLAN Al TOP.rsr Page 1 FORM 60OA-97 :FLORIDA ENERGY EFFICIENCY CODE__ FOR BUILDING CONSTRUCTION Florida Department of Community Affairs Residential Whole Building Performance Method A Project Name: SAVANA CLUB APT UNIT A2TQ Builder: Address: Permitting Office: PORT ST- LUG 14 City, State: PORT ST LUCIE, FL Permit Number: Owner: RICH PROPERTIES Jurisdiction Number: (G 1z00 Climate Zone: Central 1. New construction or existing New _ 12. Cooling systems - 2. Single family or multi -family Multi -family _ a. Central Unit Cap: 21.9 kBtu/hr _ 3. Number of units, if multifamily 1 _ SEER: 10.00 4. Number of Bedrooms 1 _ b. N/A _ 5. Is this a worst case? Yes 6. Conditioned floor area (ft2) 9ff c. N/A _ 7. Glass area & type _ _ a. Clear - single pane 54.0 ft2 _ 13. Heating systems b. Clear - double pane 0.0 ft2 _ a. Electric Strip Cap: 17.0 kBtu/hr _ c. Tint/other SC/SHGC - single pane 0.0 ft2 _ COP: 1.00 _ d. Tint/other SC/SHGC - double pane 0.0 ft2 b. N/A _ 8. Floor types a. Slab -On -Grade Edge Insulation R=0.0, 46.0(p) ft _ c. N/A _ b. N/A c. N/A 14. Hot water systems 9. Wall types _ a. Electric Resistance Cap: 30.0 gallons _ a. Concrete, Int Insul, Exterior R=3.0, 450.0 ft2 _ EF: 0.89 b. Concrete, hit Insul, Adjacent R=3.0, 289.0 ft2 _ b. N/A _ c. N/A d. N/A _ c. Conservation credits _ e. N/A (HR-Heat recovery, Solar 10. Ceiling types _ DHP-Dedicated heat pump) a. Under Attic R=19.0, 914.0 ft2 _ 15. HVAC credits b. N/A _ (CF-Ceiling fan, CV -Cross ventilation, c. N/A HF-Whole house fan, 11. Ducts _ PT -Programmable Thermostat, a. Sup: Con. Ret: Con. AH: Interior Sup. R=4.2, 40.0 ft _ RB-Attic radiant barrier, b. N/A MZ-C-Multizone cooling, MZ-H-Multizone heating) Glass/Floor Area: 0.06 Total as -built points: 11164.00 Y PASS Total base points: 12461.00 I hereby certify that the plans and specifications covered by this calculation are in compliance with the Florida Energy Code. PREPARED BY:l6eei Ir-16•s♦ -- vc. DATE:syP I hereby certify that this building,,as designed, is in compliance with the'Florida Ener X- OWNERIAGENT: DATE: Review of the plans and specifications covered by this 011�i'0IESIN. calculation indicates compliance' with the Florida Energy Code. Before construction is completed °� a this building will be inspected for compliance with Section 553.908 �•ooD�S'� Florida Statutes. BUILDING OFFICIAL: DATE: EnergyGauge® (Version: FLRCNA-200) I I G FORM 60OA-97 FLORIDA_ ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Community Affairs Residential Whole Building Performance Method A Project Name: SAVANA CLUB APT UNIT A2� TOP Builder: Address: Permitting Office: City, State: PORT ST LUCIE, FL Permit Number: Owner: RICH PROPERTIES Jurisdiction Number: Climate Zone: Central 1. New construction or existing New _ 12. Cooling systems - 2. Single family or multi -family Multi -family _ a. Central Unit 3. Number of units, if multi -family 1 _ 4. Number of Bedrooms 1 _ b. N/A 5. Is this a worst case? Yes _ 6. Conditioned floor area (ft2) 914 fie c. N/A 7. Glass area & type _ a. Clear - single pane 54.0 ft2 _ 13. Heating systems b. Clear - double pane 0.0 ft2 _ a. Electric Strip c. Tint/other SC/SHGC - single pane 0.0 ft2 _ d. Tint/other SC/SHGC - double pane 0.0 ft2 b. N/A 8. Floor types a. Slab -On -Grade Edge Insulation R=0.0, 46.0(p) ft _ c. N/A b. N/A _ c. N/A 14. Hot water systems 9. Wall types _ a. Electric Resistance a. Concrete, Int Insul, Exterior R=3.0, 450.0 ft2 _ b. Concrete, Int Insul, Adjacent R=3.0, 289.0 ft2 _ b. N/A c. N/A _ d. N/A _ c. Conservation credits e. N/A (HR-Heat recovery, Solar 10. Ceiling types _ DHP-Dedicated heat pump) a. Under Attic R=19.0, 914.0 ft2 _ 15. HVAC credits b. N/A _ (CF-Ceiling fan, CV -Cross ventilation, c. N/A HF-Whole house fan, 11. Ducts _ PT -Programmable Thermostat, a. Sup: Con. Ret: Con. AH: Interior Sup. R=4.2, 40.0 ft _ RB-Attic radiant barrier, b. N/A MZ-C-Multizone cooling, MZ-H-Multizone heating) Y Glass/Floor Area: 0.06 Total as -built points: 11164.00 PASS Total base points: 12461.00 I hereby certify that the plans and specifications covered by this calculation are in compliance with the Florida Energy Code. PREPARED BY:Nder-� -14' d IcE.s , Tiyc DATE: ? a I hereby certify that this building, as designed, is in compliance with the Florida Ener o OWNERIAGENT: DATE: /D Cap: 21.9 kBtu/hr _ SEER: 10.00 Cap: 17.0 kBtu/hr _ COP: 1.00 Cap: 30.0 gallons _ EF: 0.89 Review of the plans and AUE ST`9T� specifications covered by this 0 calculation indicates compliance �,,;'''� • _ with the Florida Energy Code. Before construction is completed a this building will be inspected for compliance with Section 553.908 �•�on�5't Florida Statutes. wE BUILDING OFFICIAL: DATE: EnergyGauge® (Version: FLRCNA-200) R FORM 60OA-97 SUMMER CALCULATIONS Residential Whole Building Performance Method A - Details ADDRESS: , PORT ST LUCIE, FL, PERMIT #: BASE AS -BUILT -GLASS TYPES .18 X Conditioned X BSPM = Points Overhang Floor Area Type/SC Ornt Len Hgt Area X SPM X SOF = Points .18 914.0 42.08 6922.6 Single, Clear E 2.0 5.0 27.0 59.31 0.81 1290.2 Single, Clear E 2.0 5.0 20.0 59.31 0.81 955.7 Single, Clear S 2.0 3.0 7.0 44.66 0.63 197.1 As -Built Total: 64.0 2443.1 WALL TYPES Area X BSPM = Points Type R-Value Area X SPM = Points Adajcent 289.0 0.7 202.3 Concrete, Int Insul, Exterior 3.0 450.0 1.40 630.0 Exterior 450.0 1.90 855.0 Concrete, Int Insul, Adjacent 3.0 289.0 0.70 202.3 Base Total: 739.0 1057.3 As -Built Total: 739.0 832.3 DOOR TYPES Area X BSPM = Points Type Area X SPM = Points Adjacent 21.0 1.60 33.6 Adjacent Wood 21.0 2.40 50.4 Exterior 0.0 0.00 0.0 Base Total: 21.0 33.6 As -Built Total: 21.0 50.4 CEILING TYPES Area X BSPM = Points Type R-Value Area X SPM = Points Under Attic 914.0 0.60 548.4 Under Attic 19.0 914.0 1.10 1005.4 Base Total: 914.0 548.4 As -Built Total: 914.0 1005.4 FLOOR TYPES Area X BSPM = Points Type R-Value Area X SPM = Points Slab 46.0(p) -31.8 -1462.8 Slab -On -Grade Edge Insulation 0.0 46.0(p) -31.90 -1467.4 Raised 0.0 0.00 0.0 Base Total: -1462.8 As -Built Total: -1467.4 INFILTRATION Area X BSPM = Points Area X SPM = Points 914.0 14.31 13079.3 914.0 14.31 13079.3 Summer Base Points: 20178.4 Summer As -Built Points: 15943.1 Total Summer X System = Cooling Total X Cap X Duct X System X Credit = Cooling Points Multiplier Points Component Ratio Multiplier Multiplier Multiplier Points 15943.1 1.000 1 0.930 0.341 1.000 5056.0 20178.4 0.3577 7217.8 15943.1 1.00 0.930 0.341 1.000 5066.0 EnergyGaugeTm DCA Form 60OA-97 r < FORM 60OA-97 WINTER_ CALCULATIONS -� Residential Whole Building Performance Method A - Details ADDRESS: , PORT ST LUCIE, FL, PERMIT #: BASE AS -BUILT GLASS TYPES .18 X Conditioned X BWPM = Points Overhang Floor Area Type/SC Ornt Len Hgt Area X WPM X WOF = Points 18 914.0 4.79 788.0 Single, Clear E 2.0 5.0 27.0 9.96 1.04 280.3 Single, Clear E 2.0 5.0 20.0 9.96 1.04 207.6 Single, Clear S 2.0 3.0 7.0 7.73 1.51 81.8 As -Built Total: 64.0 669.7 WALL TYPES Area X BWPM = Points Type R-Value Area X WPM = Points Adajcent 289.0 1.8 520.2 Concrete, Int Insul, Exterior 3.0 450.0 3.80 1710.0 Exterior 450.0 2.00 900.0 Concrete, Int Insul, Adjacent 3.0 289.0 2.30 664.7 Base Total: 739.0 1420.2 As -Built Total: 739.0 2374.7 DOOR TYPES Area X BWPM = Points Type Area X WPM = Points Adjacent 21.0 4.00 84.0 Adjacent Wood 21.0 5.90 123.9 Exterior 0.0 0.00 0.0 Base Total: 21.0 84.0 As -Built Total: 21.0 123.9 CEILING TYPES Area X BWPM = Points Type R-Value Area X WPM = Points Under Attic 914.0 0.60 548.4 Under Attic 19.0 914.0 1.00 914.0 Base Total: 914.0 648.4 As -Built Total: 914.0 914.0 FLOOR TYPES Area X BWPM = Points Type R-Value Area X WPM = Points Slab 46.0(p) -1.9 -87.4 Slab -On -Grade Edge Insulation 0.0 46.0(p) 2.50 115.0 Raised 0.0 0.00 0.01 Base Total: -87.4 As -Built Total: 115.0 INFILTRATION Area X BWPM = Points Area X WPM = Points 914.0 -0.28 -255.9 914.0 -0.28 -255.9 Winter Base Points: 2497.3 Winter As -Built Points: 3841.4 Total Winter X System = Heating Total X Cap X Duct X System X Credit = Heating Points Multiplier Points Component Ratio Multiplier Multiplier Multiplier Points 3841.4 1.000 0.930 1.000 1.000 3572.5 2497.3 1.0730 2679.6 3841.4 1.00 0.930 1.000 1.000 3572.5 EnergyGaugeTm DCA Form 60OA-97 x FORM 60OA-97 WATER HEATING & CODE COMPLIANCE STATUS. Residential Whole Building Performance Method A - Details ADDRESS: , PORT ST LUCIE, FL, PERMIT #: BASE AS -BUILT WATER HEATING Number of X Multiplier = Total Tank EF Number of X Tank X Multiplier X Credit = Total Bedrooms Volume Bedrooms Ratio Multiplier 1 2564.00 2564.0 30.0 0.89 1 1.00 2535.19 1.00 2535.2 As -Built Total: 2535.2 CODE COMPLIANCE STATUS BASE AS -BUILT Cooling + Heating + Points Points Hot Water Points = Total Points Cooling Points + Heating + Hot Water = Total Points Points Points 7217.8 2679.6 2564.0 12461.4 5056.0 3572.5 2535.2 11163.7 PASS EnergyGaugeTm DCA Form 60OA-97 r I FORM 60OA-97 Code Compliance Checklist Residential Whole Building Performance Method A - Details ADDRESS: , PORT ST LUCIE, FL, PERMIT #: 6A-21 INFILTRATION REDUCTION COMPLIANCE CHECKLIST COMPONENTS SECTION REQUIREMENTS FOR EACH PRACTICE CHECK Exterior Windows & Doors 606.1.ABC.1.1 Maximum:.3 cfm/s .ft. window area; .5 cfm/s .ft. door area. Exterior & Adjacent Walls 606.1.ABC.1.2.1 Caulk, gasket, weatherstrip or seal between: windows/doors & frames, surrounding wall; foundation & wall sole or sill plate; joints between exterior wall panels at corners; utility penetrations; between wall panels & top/bottom plates; between walls and floor. EXCEPTION: Frame walls where a continuous infiltration barrier is installed that extends from and is sealed to the foundation to the top plate. Floors 606.1.ABC.1.2.2 Penetrations/openings >1/8" sealed unless backed by truss or joint members. EXCEPTION: Frame floors where a continuous infiltration barrier is installed that is sealed to the perimeter, penetrations and seams. Ceilings 606.1.ABC.1.2.3 Between walls & ceilings; penetrations of ceiling plane of top floor; around shafts, chases, soffits, chimneys, cabinets sealed to continuous air barrier; gaps in gyp board & top plate; attic access. EXCEPTION: Frame ceilings where a continuous infiltration barrier is installed that is sealed at the perimeter, at penetrations and seams. Recessed Lighting Fixtures 606.1.ABC.1.2.4 Type IC rated with no penetrations, sealed; or Type IC or non -IC rated, installed inside a sealed box with 1/2" clearance & 3" from insulation; or Type IC rated with < 2.0 cfm from conditioned space, tested. Multi -story Houses 606.1.ABC.1.2.5 Air barrier on pqrimeter of floor cavity between floors. Additional Infiltration reqts 606.1.ABC.1.3 Exhaust fans vented to outdoors, dampers; combustion space heaters comply with NFPA, have combustion air. CA 12H f%'MICO D0CC!`01DT1\/C RIICAQI IQCQ ha Maf nr AW-00fi!Oei hV All rAQitIP_flCP--R_1 COMPONENTS SECTION REQUIREMENTS CHECK Water Heaters 612.1 Comply with efficiency requirements in Table 6-12. Switch or clearly marked circuit breaker electric or cutoff as must be provided. External or built-in heat trap required. Swimming Pools & Spas 612.1 Spas & heated pools must have covers (except solar heated). Non-commercial pools must have a pump timer. Gas spa & pool heaters must have a minimum thermal efficient of 78%. Shower heads 612.1 Water flow must be restricted to no more than 2.5 gallons per minute at 80 PSIG. Air Distribution Systems 610.1 All ducts, fittings, mechanical equipment and plenum chambers shall be mechanically attached, sealed, insulated, and installed in accordance with the criteria of Section 610. Ducts in unconditioned attics: R-6 min. insulation. HVAC Controls 607.1 Separate readily accessible manual or automatic thermostat for each system. Insulation 604.1, 602.1 Ceilings -Min. R-19. Common walls -Frame R-11 or CBS R-3 both sides. Common ceiling & floors R-11. EnergyGaugeTm DCA Form 60OA-97 EnergyGauge®/FlaRES'97 FLRCNA-200 4 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE SCORE* = 84.0 The higher the score, the more efficient the home. RICH PROPERTIES,, PORT ST LUCIE, FL, 1. New construction or existing New - 12. Cooling systems ' 2. Single family or multi -family Multi -family - a. Central Unit Cap: 21.9 kBtu/hr - 3. Number of units, if multi -family 1 - SEER: 1.0.00 - 4. Number of Bedrooms 1 - b. N/A - 5. Is this a worst case? Yes - - 6. Conditioned floor area (W) 9I47ft2 c. N/A - 7. Glass area & type - - a. Clear - single pane 54.0 ft2 _ 13. Heating systems b. Clear - double pane 0.0 ft2 - a. Electric Strip Cap: 17.0 kBtu/hr - c. Tint/other SC/SHGC - single pane 0.0 ft2 - COP: 1.00 - d. Tintlother SC/SHGC - double pane 0.0 ft2 b. N/A - 8. Floor types - - a. Slab -On -Grade Edge Insulation R=0.0, 46.0(p) ft - c. N/A - b. N/A - - c. N/A 14. Hot water systems 9. Wall types - a. Electric Resistance Cap: 30.0 gallons - a. Concrete, Int Insul, Exterior R=3.0, 450.0 ft2 - EF: 0.89 - b. Concrete, Int Insul, Adjacent R=3.0, 289.0 ft2 - b. N/A - c. N/A - - d. N/A - c. Conservation credits - e. N/A (HR-Heat recovery, Solar 10. Ceiling types - DHP-Dedicated heat pump) a. Under Attic R=19.0, 914.0 ft2 - 15. HVAC credits - b. N/A - (CF-Ceiling fan, CV -Cross ventilation, c. N/A HF-Whole house fan, 11. Ducts - PT -Programmable Thermostat, a. Sup: Con. Ret: Con. AH: Interior Sup. R=4.2, 40.0 ft - RB-Attic radiant barrier, b. N/A MZ-C-Multizone cooling, MZ-H-Multizone heating) f certify that this home has complied with the Florida Energy Efficiency Code For Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature: Date: JUE sT47 F Address of New Home: City/FL Zip: c'0 WU l %. *NOTE: The home's estimated energy performance score is only available through the FLARES computer program. This is not a Building Energy Rating. I our score is 80 or greater or 86 or a US EPADOE Ener StarTmdesi ation your home may qualify for energy eff ciency mortgage (EEM incentives if you obtain a Florida Energy Gauge Rating. Contact the Energy Gauge Hotline at 4071638-1492'or see the Energy Gauge web site at www.fsec. ucf. edu for information and a list of certified Raters. For information about Florida's Energy Efficiency Code For Building Construction, contact the Department of Community Affairs at 8501487-1824. EnergyGauge® (Version: FLRCNA-200) 0 RIGHT-J LOAD AND EQUIPMENT SUMMARY 0Entire House FES, INC. Job: SAVANA CLUB UNIT A2-TOP 4121/99 34 N.W. 168TH. STREET, NORTH MIAMI BEACH, FL 33169 Phone: 305-653-0212 Fax: 305-653-0232 Project • • For: SAVANNA-CL-UV UNIT�A2-TOP, F Phone: WG—W__--.1 Notes: SAVANA CLUB UNIT A2-TOP Design Information Weather: West Palm Beach, FL, US Winter Design Conditions Summer Design Conditions Outside db 47 OF Outside db 90 OF Inside db 71 OF Inside db 75 OF Design TD 24 OF Design TD 15 OF L Daily range Relative humidity 50 % Moisture difference 61 gr/lb Heating Summary Building heat loss 12568 Btuh Ventilation air 0 cfm Ventilation air loss 0 Btuh Design heat load 12568 Btuh Infiltration Method Construction quality Fireplaces Area (ftz) Volume (ft') Air changes/hour Equiv. AVF (cfm) Simplified Average 0 Heating Cooling [914--914 8226 8226 1.0 0.5 137 69 Heating Equipment Summary Make n/a Trade n/a Efficiency Heating Input Heating output Heating temp rise Actual heating fan Heating air flow factor Space thermostat 100.0 EFF 0 Btuh 0 Btuh 0 OF 559 cfm 0.044 cfm/Btuh Sensible Cooling Equipment Load Sizing Structure 12903 Btuh Ventilation 825 Btuh Design temperature swing 3.0 OF Use mfg. data n Rate/swing multiplier 0.95 Total sens. equip. load 13041 Btuh Latent Cooling Equipment Load Sizing Internal gains 460 Btuh Ventilation 2088 Btuh Infiltration 2868 Btuh Total latent equip. load 5416 Btuh Total equipment load 18458 Btuh Cooling Equipment Summary Make Trade Efficiency Sensible cooling Latent cooling Total cooling Actual cooling fan Cooling air flow factor Load sensible heat ratio 0.0 EER 0 Btuh 0 Btuh 0 Btuh 559 cfm 0.043 cfm/Btuh 72 % Printout certified by ACCA to meet all requirements of Manual J 7th Ed. wr�g htsoft Right -Suite Residential"' 5.0.58 RSR23656 2001-Oct-09 17:12:03 ACC% H:\Wrightsoft LOAD CALCS\SAVANNA CLUB\PLAN A2 TOP.rsr Page 1 Ll I RIGHT-J SHORT FORM Entire House WR FES, INC. Job: SAVANA CLUB UNIT A2-TOP 4121199 34 N.W. 168TH. STREET, NORTH MIAMI BEACH, FL 33169 Phone: 305-653-0212 Fax: 305-653-0232 Project• • For: SAVANNA CLUB UNITP_,_FLJ Phone: WC=W Design Information Htg Clg Infiltration Outside db (OF) 47 90 Method Simplified Inside db (OF) 71 75 Construction quality Average Design TD (OF) 24 15 Fireplaces 0 Daily range - L Inside humidity (%) - 50 Moisture difference (gr/lb) - 61 HEATING EQUIPMENT Make n/a Trade n/a Efficiency 100.0 EFF Heating input 0 Btuh Heating output 0 Btuh Heating temperature rise 0 OF Actual heating fan 559 cfm Heating air flow factor 0.044 cfm/Btuh Space thermostat COOLING EQUIPMENT Make Trade Efficiency 0.0 EER Sensible cooling . 0 Btuh Latent cooling 0 Btuh Total cooling 0 Btuh Actual cooling fan 559 cfm Cooling air flow factor 0.043 cfm/Btuh Load sensible heat ratio 72 % ROOM NAME Area Htg load Clg load Htg AVF Clg AVF (ft2) (Btuh) (Btuh) (cfm) (cfm) UNIT-1 ALT. 914— 12568 12903 559 559 Entire House d 914 12568 12903 559 559 Ventilation air 0 825 Equip. @ 0.95 RSM 13041 ' Latent cooling 5416 -Al ^ I r%4A 42Ar.R I rira I AR -CI Printout certified by ACCA to meet all requirements of Manual J 7th Ed. ,$_: wrightsoft Right -Suite Residential TM 5.0.58 RSR23656 2001-Oct-09 17:12:04 C)M H:1Wrightsoft LOAD CALCSISAVANNA CLUBIPLAN A2 TOP.rsr Page 1 Ott I^ N W rJ vN DD 0 Ito D� 0 c; CD CD CL D � Z myy 9 Op V O � m N N W m M O r CD r. C n 0 CD CD T O c0 0 V 0 CT A W N O co 0 V O¢f CT A W N+ D-IGrrfA M O -i�rrfA O» o o u; � ZT n 0 d x z 0 o m m ag 920 eft X4 m 6 6- C ccn N Q .�N N f0 N 'N 5E 61 V. N 4 O N Ll 7. O_ � y 3�(@i O a —'O .r C. V1 O m c� O to 7 w n D7 V! 7 CN d �Z. N O N C N N Om 7 0 cp 3 cp 3 (D 7' O O A �O (D Lb. O OOram^CD O Ci N vUM .O. y (D 770 O' d 7 O Cfl dS 7 O cG d O N O. NnO y G_ O!.0 C• (/1 �. N N N _ 7 - 00 N n 00 p f/i p CQ -n ny � a H)0 3 � n n m 0rr m� (A.103 3� g�. ± �� �. �j D "0 A c. 9 N n �S � � m � CD d 0 CS D1 "� CD O. 0 Cr SO -w cp d 0 (J 0) 0 CS 21 2 V1 fA Z Z -w cp d 0 C7 0f �. cp n 0 [7 N �'E' g �P. °�a agN a c>zcNim av za �z:0 .z°y . ^/mom \�@ N + + N N r + TI co 0000 A cD 00000+ O OO+N W 00— 0000OI CJI O OO+N W fG 'O O 10, CGOOOA OGGCO tJ OOCO.D•IV in OA OO COA N in = OC O O O O O O N O O O O O O N O O++ N N + + O N O m N O O O N O V S S S S S S O O++ N N O 0 0 0 0 0 O 0 0 C C 0 0 0 G1 O O W+ C N O V A O O O O O O C O W O N D O O.}SMOOOOOO S O c0 N A A j c(�� OD V O 0 7 C OOO OOA OOO o 0 0 0 OO�}0 co 0 N.1S a O OOA OO OSS++ V (p N w f0 nN CD m OD i S S i N ' N fD 0 N Cfl 0000 OD V A 0000 O 00000 O 00VIS" w 00 000OOW c Er}$ }S 7S N N+ CT K) CON0 i i + N N N O W+_c0 W W W W cD i S S Ov d. N O 0 0 0 coo O O O W O O W W N COMM O O 0 O O O O O W cD 0 0 0 W O+ 0 0 0 0 0 0 0 0 0 �CD i c 0 Z 0 0 O V O c+ m C" ccn N w C� OD V D) 0 +N \ 0 O OOOOO 00000 A OOOO A O O O+ OOO c0O CA 0000 Oi+. O OO++ V O + S S S cG N x D C 0 S S cn cNil G A j' 0 N W to O. C t0D 0000 co V pp OOOOA O 00000 W 000 V V NN O O N 0000 OAC� C .T ss *S S i *S SS *S i i i g.�. N N+cp O00 N 0 +� W W W W C071O CO c) OO$ W O O W W O O O O O O O O O O O W O OO W O 00m OOO CA O CD �j � gg SS ss �j5 Sq j tog Sz?z i i i i S i i 192 m m > - ^^ N =w Y+ ? Z CD r nCD 0 O go 0 T O 9 cn 8 mT N 1 „ x —I G FORM 60OA-97 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Community Affairs Residential Whole Building Performance Method A./.d Project Name: SAVANNA CLUB PLAW 9B t Builder: Address: Permitting Office: PORT %7*- 40414-7 City, State: Permit Number: Owner: Jurisdiction Number: 66AZ00 Climate Zone: Central 1. New construction or existing New _ 12. Cooling systems . 2. Single family or multi -family Multi -family _ a. Central Unit 3. Number of units, if multi -family 1 _ 4. Number of Bedrooms 1 _ b. N/A 5. Is this a worst case? Yes _ 6. Conditioned floor area (ft2) T013 ftz c. N/A 7. Glass area & type _ a. Clear - single pane 96.0 ftz _ 13. Heating systems • b. Clear - double pane 0.0 ftz _ a. Electric Strip c. Tint/other SC/SHGC - single pane 0.0 ft2 _ d. Tint/other SC/SHGC - double pane 0.0 ft2 b. N/A • 8. Floor types _ a. Slab -On -Grade Edge Insulation R=0.0, 84.0(p) ft _ c. N/A b. N/A _ c. N/A 14. Hot water systems 9. Wall types _ a. Electric Resistance a. Concrete, Int Insul, Exterior R=5.0, 336.0 ft2 _ b. Concrete, Int Insul, Adjacent R=5.0, 309.0 ft2 _ b. N/A c. N/A _ d. N/A _ c. Conservation credits e. N/A (HR Heat recovery, Solar 10. Ceiling types _ DHP-Dedicated heat pump) a. N/A _ 15. HVAC credits b. N/A _ (CF-Ceiling fan, CV -Cross ventilation, c. N/A BF -Whole house fan, 11. Ducts _ PT -Programmable Thermostat, a. Sup: Con. Ret: Con. AH: Interior Sup. R=4.2, 30.0 ft _ RB-Attic radiant barrier, b. N/A MZ-C-Multizone cooling, MZ-H-Multizone heating) Glass/Floor Area: 0.09 Total as -built points: 10315.00 ' PASS Total base points: 11725.00 hereby certify that the plans and specifications covered by this calculation are in compliance with the Florida Energy Code. PREPARED BY:AIdr �09 _'�, S,vc DATE: I hereby certify that this building, as designed, is in compliance with the Florida Ene � y de. OWNER/AGENT: DATE: Cap: 24.3 kBtu/hr SEER 10.00 _ Cap: 17.0 kBtu/hr COP: 1.00 Cap: 40.0 gallons _ EF: 0.89 Review of the plans and zip sT aT�0 specifications covered by this yob = calculation indicates compliance irp .,•,...., 1. with the Florida Energy Code. Before construction is completed a this building will be inspected for compliance with Section 553.908 icon��� Florida Statutes. wa BUILDING OFFICIAL: DATE: EnergyGauge® (Version: FLRCNA-200) r FORM 60OA-97 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Community Affairs Residential Whole Building Performance Method A Project Name: SAVANNA CLUB PLAN B1 BOT Builder: Address: Permitting Office: City, State: Permit Number: Owner: Jurisdiction Number: Climate Zone: Central 1. New construction or existing New _ 12. Cooling systems 2. Single family or multi -family Multi -family _ a. Central Unit 3. Number of units, if multi -family 1 4. Number of Bedrooms 1 _ b. N/A 5. Is this a worst case? Yes 6. Conditioned floor area (ft2) 1'Olf 3-ft? c. N/A 7. Glass area & type a. Clear - single pane 96.0 ft2 _ 13. Heating systems - b. Clear - double pane 0.0 ft2 _ a. Electric Strip c. Tint/other SC/SHGC - single pane 0.0 ft2 _ d. Tint/other SC/SHGC - double pane 0.0 ft2 b. N/A 8. Floor types a. Slab -On -Grade Edge Insulation R=0.0, 84.0(p) ft _ c. N/A b. N/A _ c. N/A 14. Hot water systems 9. Wall types _ a. Electric Resistance a. Concrete, Int Insul, Exterior R=5.0, 336.0 ft2 _ b. Concrete, Int Insul, Adjacent R=5.0, 309.0 ft2 _ b. N/A c. N/A _ d. N/A _ c. Conservation credits e. N/A (HR-Heat recovery, Solar 10. Ceiling types _ DHP-Dedicated heat pump) a. N/A _ 15. HVAC credits b. N/A _ (CF-Ceiling fan, CV -Cross ventilation, c. N/A BF -Whole house fan, 11. Ducts _ PT -Programmable Thermostat, a. Sup: Con. Ret: Con. AH: Interior Sup. R=4.2, 30.0 ft _ RB-Attic radiant barrier, b. N/A MZ-C-Multizone cooling, MZ-H-Multizone heating) Glass/Floor Area: 0.09 Total as -built points: 10315.00 ' PASS Total base points: 11725.00 I hereby certify that the plans and specifications covered by this calculation are in compliance with the Florida Energy Code. PREPARED BY:A16-re� IcF:S DATE: �Z�wi I hereby certify that this building, as desi ned, is in compliance with the Florida En 7 y C e. OWNER/AGENT: DATE: Cap: 24.3 kBtu/hr _ SEER: 10.00 Cap: 17.0 kBtu/hr COP: 1.00 Cap: 40.0 gallons EF: 0.89 Review of the plans and ZKE ST AT�O specifications covered by this tio4 - calculation indicates compliance�'� with the Florida Energy Code. Before is completed construction a this building will be inspected for compliance with Section 553.908 •COD�y'S Florida Statutes. wE BUILDING OFFICIAL: DATE: EnergyGauge® (Version: FLRCNA-200) FORM 60OA-97 SUMMER CALCULATIONS Residential Whole Building Performance Method A - Details ADDRESS: , , , PERMIT #: . BASE AS -BUILT - GLASS TYPES .18 X Conditioned X BSPM = Points Overhang Floor Area Type/SC Ornt Len Hgt Area X SPM X SOF = Points .18 1013.0 42.08 7672.4 Single, Clear E 1.0 5.5 20.0 59.31 0.96 1141.9 Single, Clear E 5.0 7.7 56.0 59.31 0.65 2164.6 Single, Clear E 1.0 5.5 20.0 59.31 0.96 1143.4 As -Built Total: 96.0 4449.9 WALL TYPES Area X BSPM = Points Type R-Value Area X SPM = Points Adajcent 309.0 0.7 216.3 Concrete, Int Insul, Exterior 5.0 336.0 1.00 336.0 Exterior 336.0 1.90 638.4 Concrete, Int Insul, Adjacent 5.0 309.0 0.60 185.4 Base Total: 645.0 854.7 As -Built Total: 645.0 521.4 DOOR TYPES Area X BSPM = Points Type Area X SPM = Points Adjacent 21.0 1.60 33.6 Adjacent Wood 21.0 2.40 50.4 Exterior 0.0 0.00 0.0 Base Total: 21.0 33.6 As -Built Total: 21.0 50.4 CEILING TYPES Area X BSPM = Points Type R-Value Area X SPM = Points Under Attic 0.0 0.00 0.0 Base Total: 0.0 0.0 As -Built Total: 0.0 0.0 FLOOR TYPES Area X BSPM = Points Type R-Value Area X SPM = Points Slab 84.0(p) -31.8 -2671.2 Slab -On -Grade Edge Insulation 0.0 84.0(p) -31.90 -2679.6 Raised 0.0 0.00 0.0 Base Total: -2671.2 As -Built Total: -2679.6 INFILTRATION Area X BSPM = Points Area X SPM = Points 1013.0 14.31 14496.0 1013.0 14.31 14496.0 Summer Base Points: 20385.5 Summer As -Built Points: 16838.1 Total Summer X System = Cooling Total X Cap X Duct X System X Credit = Cooling Points Multiplier Points Component Ratio Multiplier Multiplier Multiplier Points 16838.1 1.000 1 '0.930 0.341 1.000 5339.9 20385.5 03577 7291.9 16838.1 1.00 0.930 0.341 1.000 5339.9 EnergyGaugeTM DCA Form 60OA-97 FORM 60OA-97 WINTER CALCULATIONS Residential Whole Building Performance Method A - Details ADDRESS: , , , PERMIT #: BASE AS -BUILT - GLASS TYPES .18 X Conditioned X BWPM = Points • Overhang Floor Area Type/SC Ornt Len Hgt Area X WPM X WOF = Points 18 1013.0 4.79 873.3 Single, Clear E 1.0 5.5 20.0 9.96 1.01 201.2 Single, Clear E 5.0 7.7 56.0 9.96 1.09 609.7 Single, Clear E 1.0 5.5 20.0 9.96 1.01 201.2 As -Built Total: 96.0 1012.1 -WALL TYPES Area X BWPM = Points Type R-Value Area X WPM = Points Adajcent 309.0 1.8 556.2 Concrete, Int Insul, Exterior 5.0 336.0 2.90 974.4 Exterior 336.0 2.00 672.0 Concrete, Int Insul, Adjacent 5.0 309.0 1.90 587.1 Base Total: 645.0 1228.2 As -Built Total: 645.0 1561.5 DOOR TYPES Area X BWPM = Points Type Area X WPM = Points Adjacent 21.0 4.00 84.0 Adjacent Wood 21.0 5.90 123.9 Exterior 0.0 0.00 0.0 Base Total: 21.0 84.0 As -Built Total: 21.0 123.9 CEILING TYPES Area X BWPM = Points Type R-Value Area X WPM = Points Under Attic 0.0 0.00 0.0 Base Total: 0.0 0.0 As -Built Total: 0.0 0.0 FLOOR TYPES Area X BWPM = Points Type R-Value Area X WPM = Points Slab 84.0(p) -1.9 -159.6 Slab -On -Grade Edge Insulation 0.0 84.0(p) 2.50 210.0 Raised 0.0 0.00 0.0 Base Total: -159.6 As -Built Total: 210.0 INFILTRATION Area X BWPM = Points Area X WPM = Points 1013.0 -0.28 -283.6 1013.0 -0.28 -283.6 Winter Base Points: 1742.3 Winter As -Built Points: 2623.9 Total Winter X System = Heating Total X Cap X Duct X System X Credit = Heating Points Multiplier Points Component Ratio Multiplier Multiplier Multiplier Points 2623.9 1.000 0.930 1.000 1.000 2440.2 1742.3 1.0730 1869.5 2623.9 1.00 0.930 1.000 1.000 2440.2 EnergyGaugeTm DCA Form 60OA-97 r FORM 60OA-97 WATER HEATING & CODE COMPLIANCE STATUS Residential Whole Building Performance Method A - Details ADDRESS: , , , PERMIT #: BASE AS -BUILT -WATER HEATING Number of X Multiplier = Total • Tank EF Number of X Tank X Multiplier X Credit = Total Bedrooms Volume Bedrooms Ratio Multiplier 1 2564.00 2564.0 40.0 0.89 1 1.00 2535.19 1.00 2535.2 As -Built Total: 2535.2 CODE COMPLIANCE STATUS BASE AS -BUILT Cooling + Heating + Points Points Hot Water Points = Total Points Cooling Points + Heating + Hot Water = Total Points Points Points 7291.9 1869.6 2564.0 11725.4 5339.9 2440.2 2635.2 10315.3 PASS :..IC en.--et- EnergyGauge'rm DCA Form 60OA-97 e FORM 60OA-97 Code Compliance Checklist Residential Whole Building Performance Method A - Details ADDRESS: , , , PERMIT #: 6A-21 INFILTRATION REDUCTION COMPLIANCE CHECKLIST COMPONENTS SECTION REQUIREMENTS FOR EACH PRACTICE CHECK Exterior Windows & Doors 606.1.ABC.1.1 Maximum:.3 cfm/s .ft. window area; .5 cfm/s .ft. door area. Exterior & Adjacent Walls 606.1.ABC.1.2.1 Caulk, gasket, weatherstrip or seal between: windows/doors & frames, surrounding wall; foundation & wall sole or sill plate; joints between exterior wall panels at comers; utility penetrations; between wall panels & top/bottom plates; between walls and floor. EXCEPTION: Frame walls where a continuous infiltration barrier is installed that extends from and is sealed to the foundation to the top plate. Floors 606.1.ABC.1.2.2 Penetrations/openings >1/8" sealed unless backed by truss or joint members. EXCEPTION: Frame floors where a continuous infiltration barrier is installed that is sealed to the perimeter, penetrations and seams. Ceilings 606.1.ABC.1.2.3 Between walls & ceilings; penetrations of ceiling plane of top floor; around shafts, chases, soffits, chimneys, cabinets sealed to continuous air barrier; gaps in gyp board & top plate; attic access. EXCEPTION: Frame ceilings where a continuous infiltration barrier is installed that is sealed at the perimeter, at penetrations and seams. Recessed Lighting Fixtures 606.1.ABC.1.2.4 Type IC rated with no penetrations, sealed; or Type IC or non -IC rated, installed inside a sealed box with 1/2" clearance & 3" from insulation; or Type IC rated with < 2.0 cfm from conditioned space, tested. Multi -story Houses 606.1.ABC.1.2.5 Air barrier on perime r of floor cavity between floors. Additional Infiltration reqts 606.1.ABC.1.3 Exhaust fans vented to outdoors, dampers; combustion space heaters comply with NFPA, have combustion air. &A_ff9 rVirUED DDCQC`DIDTIVC MCAQI IDCQ /mne4 hn maf nr nvrnnr11nr1 her m11 racirllancac I COMPONENTS SECTION REQUIREMENTS CHECK Water Heaters 612.1 Comply with efficiency requirements in Table 6-12. Switch or clearly marked circuit breaker electric or cutoff as must be provided. External or built-in heat trap required. Swimming Pools & Spas 612.1 Spas & heated pools must have covers (except solar heated). Non-commercial pools must have a pump timer. Gas spa & pool heaters must have a minimum thermal efficient of 78%. Shower heads 612.1 Water flow must be restricted to no more than 2.5 gallons per minute at 80 PSIG. Air Distribution Systems 610.1 All ducts, fittings, mechanical equipment and plenum chambers shall be mechanically attached, sealed, insulated, and installed in accordance with the criteria of Section 610. Ducts in unconditioned attics: R-6 min. insulation. HVAC Controls 607.1 Separate readily accessible manual or automatic thermostat for each system. Insulation 604.1, 602.1 Ceilings -Min. R-19. Common walls -Frame R-11 or CBS R-3 both sides. Common ceiling & floors R-11. EnergyGaugeTm DCA Form 60OA-97 EnergyGauge®/FlaRES'97 FLRCNA-200 v 0 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE SCORE* = 84.3 The higher the score, the more efficient the home. 1. New construction or existing New _ 12. Cooling systems - 2. Single family or multi -family Multi -family _ a. Central Unit Cap: 24.3 kBtu/hr _ 3. Number of units, if multi -family 1 _ SEER: 10.00 4. Number of Bedrooms 1 _ b. N/A 5. Is this a worst case? Yes 6. Conditioned floor area (ft2) 1013 ftz c. N/A 7. Glass area & type a. Clear - single pane 96.0 ft2 _ 13. Heating systems ' b. Clear - double pane 0.0 ft2 _ a. Electric Strip Cap: 17.0 kBtu/hr _ c. Tint/other SC/SHGC - single pane 0.0 ft2 _ COP: 1.00 d. Tint/other SC/SHGC - double pane 0.0 ft2 b. N/A _ 8. Floor types a. Slab -On -Grade Edge Insulation R=0.0, 84.0(p) ft _ c. N/A b. N/A _ c. N/A 14. Hot water systems 9. Wall types _ a. Electric Resistance Cap: 40.0 gallons a. Concrete, hit Insul, Exterior R=5.0, 336.0 ft2 _ EF: 0.89 _ b. Concrete, Int Insul, Adjacent R=5.0, 309.0 ft2 _ b. N/A c. N/A _ d. N/A _ c. Conservation credits e. N/A (HR-Heat recovery, Solar 10. Ceiling types _ DHP-Dedicated heat pump) a. N/A _ 15. HVAC credits _ b. N/A _ (CF-Ceiling fan, CV -Cross ventilation, c. N/A BF -Whole house fan, 11. Ducts _ PT -Programmable Thermostat, a. Sup: Con. Ret: Con. AH: Interior Sup. R=4.2, 30.0 ft _ RB-Attic radiant barrier, b. N/A MZ-C-Multizone cooling, MZ-H-Multizone heating) certify that this home has complied with the Florida Energy Efficiency Code For Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed -based on installed Code compliant features. Builder Signature: Address of New Home: Date: City/FL Zip: p. 04THE sr9� rnn COD w8 *NOTE: The home's estimated energy performance score is only available through the FLARES computer program. This is not a Building Energy Rating. If your score is 80 or greater (or 86 for a US EPADOE EnergyStar designation), your home may qualms for energy efficiency mortgage (EEM incentives ifyou obtain a Florida Energy Gauge Rating. Contact the Energy Gauge Hotline at 4071638-1492 or see the Energy Gauge web site at www.fsec. ucf edu for information and a list of certified Raters. For information about Florida's Energy Efficiency Code For Building Construction, ' contact the Department of Community Affairs at 8501487-1824. EnergyGauge® (Version: FLRCNA-200) RIGHT-J LOAD AND EQUIPMENT SUMMARY Entire House FES, INC. Job: 01089 4121199 34 N.W. 168TH. STREET, NORTH MIAMI BEACH, FL 33169 Phone: 305-653-0212 Fax: 305-653-0232 Project• • For: SAVANNA CLUB APT ;PLAN-61—FL� Phone: WC=e Notes: Design Information Weather: Fort Lauderdale, FL, US Winter Design Conditions Summer Design Conditions Outside db 46 OF Outside db 91 OF Inside db 71 OF Inside db 75 OF Design TD 25 OF Design TD 16 OF Daily range M Relative humidity 50 % Moisture difference 60 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Building heat loss 10292 Btuh Structure 11127 Btuh Ventilation air 0 cfm Ventilation 1760 Btuh Ventilation air loss 0 Btuh Design temperature swing 3.0 OF Design heat load 10292 Btuh Use mfg. data n Rate/swing multiplier 0.96 Infiltration Total sens. equip. load 12372 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Internal gains 690 Btuh Ventilation 4064 Btuh Heating Cooling Infiltration 3094 Btuh Area (ftZ) 013� Total latent equip. load 7848 Btuh Volume (ft3) 9117-91`17 Air changes/hour 1.0 0.5 Total equipment load 20220 Btuh Equiv. AVF (cfm) 152 76 Heating Equipment Summary Cooling Equipment Summary Make n/a Make • Trade Trade n/a Efficiency 100.0 EFF Efficiency 0.0 EER Heating input 0 Btuh Sensible cooling 0 Btuh Heating output 0 Btuh Latent cooling 0 Btuh Heating temp rise 0 OF Total cooling 0 Btuh Actual heating fan 482 cfm Actual cooling fan 482 cfm Heating air flow factor 0.047 cfm/Btuh Cooling air flow factor 0.043 cfm/Btuh Space thermostat Load sensible heat ratio 62 % Printout certified by ACCA to meet all requirements of Manual J 7th Ed. wrrghtsoft Right -Suite Residential 5.0.45 RSR23656 2001-Jul-05 09:14:39 i1CCi\ H:\Wrightsoft LOAD CALCS199049\U2BOT.rsr Page 1 7 O rat CD a; CD a ^n `! 0 3 CD CD N O W L zF m a O (O W V O U) A W N O c0 co J C) cn A W N+ D—Iprrtn S -iOrrm g �o u;v^ n 0 a F X Z O 0 g =��i w m inc O m �c4 .0s. Z77 (G (mii vmi C N .O. N N O S' O G 7. O O f-i!v y y 3 (D O 7 in O '� N !� to d 7 O r N d 7 O m O U) O w y co '0 O m C O f0 3 2 to r1^ m C w mo 7• oNNmD) w Q�m y N 770. O t�0 `d 00 77 p, Nd Co y 5 O�.Z (D 2C=�� N HN�Np j f�� Nd O N(n �N .Z1T �mOD d� N= 11 � w ww 3 d d m w 0El �- 7 _. + J �m dO cw '""(D dOQw '""N d0 0, 0) O O'w 2mm ZZ —M d0 cw "'m 0. C) O'w O 11 D� o_ A �•� nN d m d t�tNu DD O + 0z0ccoo Do w+ WW + wwN•P OZ0co Zn 0� + (G i'V O 3 w v U3 + w o o o a Ery Zi o d 7 d m �r2 2 `. N O O O O A O 0 0 0 0 0+ O O O+ N W + O A+ N N O O O O m O O O+ N W C) = ^^m N lcv + N O 0 co OOOOCD W OOOCO W OOcoA W C) OOC) 0000++ C O(DA W p + OO 000 000 N+ 00+0++ W N C, OC, _n O0 (T 000OON C) W OD OC)O C)00coOCD OOC)C)C)CD * y m m O k O (O fW.1 (A+) w 0• CDO +W O � J OD O OOOO A O O OOO O (WA O OO co O 0)0 N 0+ J N O OOO OO 000000 O$TO OO O7SsN d' N (O n CD r- N • M O O N O W N N000 co 00000 000 OO A O O co ^� C ss ¢$qq zz ggSS (T w (ov d N V000 V 00 0 000000 000000 o t OOOOO(T 00 (O � 000 W O (T _ 3D S O » k + O W fp W (Aj w O Y O [�C 0\ +(,p \ V OOOOOA 000000 000(O O 0) N 00+ J N 000000 000000 OOOOON �' O Z � X � w M + M k »: i '� i N, }$ C . . N v A j N A V O a 0 coA N co OOON V 1 00000 000000 000 (TOO 00 N 00000co ^W C O W ,'S CA U93 co V000J00 O 000000 000000 O (WO 00000(T W 00(o co m (.) w • S Z» i i i i• (O �y � ♦ »» �•}� • S♦ » ryy » 1ST 111111 HIM CD YI O 20 N m m q RIGHT-J CALCULATION PROCEDURES A, B, C, D Entire House FES, INC. Job:01089 4/21199 34 N.W. 168TH. STREET, NORTH MIAMI BEACH, FL 33169 Phone: 305-653-0212 Fax: 305-653-0232 Procedure A - Winter Infiltration HTM Calculation* 1. Winter infiltration AVF 1.0 ach x 9117 ft3 x 0.0167 = 152 cfm 2. Winter infiltration load 1.1 x 152 cfm x 25 OF Winter TD = 4187 Btuh 3. Winter infiltration HTM 4187 Btuh / 117 ft2 Total window = 35.8 Btuh/ft2 and door area Procedure B - Summer Infiltration HTM Calculation 1. Summer infiltration AVF 0.5 ach x 9117 ft3 x 0.0167 = 76 cfm 2. Summer infiltration load 1.1 x76 cfm x 16 OF SummerTD = 1340 Btuh 3. Summer infiltration HTM 1340 Btuh / 117 ft2 Total window = 11.5 Btuh/ft2 and door area Procedure C - Latent Infiltration Gain 0.68 x 60 gr/lb moist.diff. x 76 cfm = 3094 Btuh rroceaurU LJ - r-gUIFJIIItl11L 011-1119 L-Uaua 1. Sensible sizing load Sensible ventilation load 1.1 x 100 cfm vent. x 16 OF Summer TD = 1760 Btuh Sensible load for structure (Line 19) + 11127 Btuh Sum of ventilation and structure loads = 12887 Btuh Rating and temperature swing multiplier x 0.96 Equipment sizing load - sensible = 12372 Btuh 2. Latent sizing load Latent ventilation load 0.68 x 100 cfm - vent. x 60 gr/lb moist.diff. _ 4064 Btuh Internal loads = 230 Btuh x 3 people + 690 Btuh Infiltration load from Procedure C + 3094 Btuh Equipment sizing load - latent = 7848 Btuh *Construction Quality is: a No. of Fireplaces is: 0 Bold/italic values have been manually overridden Printout certified by ACCA to meet all requirements of Manual J 7th Ed. �• wrjghtsoft Right -Suite Residential*^+ 5.0.45 RSR23656 2001-Jul-05 09:14:39 ACCK H:\Wdghtsoft LOAD CALCS\99049\U2BOT.rsr Page 1 a a FORM 60OA-97 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Community Affairs Residential Whole Building Performance Method A Project Name: SAVANNA CLUB PLAN' 2 B0_ Builder: Address: Permitting Office: PORT sT MIC-1 ' City, State: PORT ST LUCIE, FL Permit Number: Owner: RICH PROPERTIES Jurisdiction Number: G610,66 Climate Zone: Central 1. New construction or existing New 2. Single family or multi -family Multi -family _ 3. Number of units, if multi -family 1 4. Number of Bedrooms 1 _ 5. Is this a worst case? Yes 6. Conditioned floor area (ft2) C1084aft2- 7. Glass area & type _ a. Clear - single pane 67.0 ft2 - b. Clear - double pane 0.0 ft2 _ c. Tint/other SC/SHGC - single pane 0.0 ft2 _ d. Tint/other SC/SHGC - double pane 0.0 ft2 8. Floor types _ a. Slab -On -Grade Edge Insulation R=0.0, 78.0(p) ft b. N/A c. N/A 9. Wall types a. Frame, Wood, Exterior R=3.0, 110.0 ft2 b. Concrete, Int Insul, Adjacent R=3.0, 309.0 ft2 _ c. N/A d. N/A e. N/A 10. Ceiling types a. N/A b. N/A _ c. N/A 11. Ducts a. Sup: Con. Ret: Con. AH: Interior Sup. R=4.2, 40.0 ft b. N/A 12. Cooling systems a. Central Unit Cap: 26.0 kBtu/hr _ SEER:10.00 _ b. N/A c. N/A 13. Heating systems a. Electric Strip Cap: 17.0 kBtu/hr _ COP: 1.00 _ b. N/A c. N/A 14. Hot water systems a. Electric Resistance Cap: 40.0 gallons EF: 0.89 _ b. N/A c. Conservation credits _ (HR-Heat recovery, Solar DHP-Dedicated heat pump) 15. HVAC credits (CF-Ceiling fan, CV -Cross ventilation, HF-Whole house fan, PT -Programmable Thermostat, RB-Attic radiant barrier, MZ-C-Multizone cooling, MZ-H-Multizone heating) Glass/Floor Area: 0.06 Total as -built points: 9935.40 y PASS Total base points: 11767.00 I hereby certify that the plans and specifications covered by this calculation are in compliance with the Florida Energy Code. PREPARED BY:A/dre-l- 5-Wai PE.S ZLM DATE: I hereby certify that this building, -as desi 'ed, is in compliance with the Florida En C e. OWNER/AGENT: DATE: Review of the plans and STATF specifications covered by this o4Tx� calculation indicates compliance with the Florida Energy Code. Before construction is completed this building will be inspected for compliance with Section 553.908 11•�oD�5't Florida Statutes. wE BUILDING OFFICIAL: DATE: EnergyGauge® (Version: FLRCNA-200) 0 I FORM 60OA-97 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Community Affairs Residential Whole Building Performance Method A Project Name: SAVANNA CLUB PLAN B2 BOT Builder: Address: Permitting Office: City, State: PORT ST LUCIE, FL Permit Number: Owner: RICH PROPERTIES Jurisdiction Number: Climate Zone: Central .1. New construction or existing New _ 12. Cooling systems 2. Single family or multi -family Multi -family _ a. Central Unit 3. Number of units, if multi -family 1 _ 4. Number of Bedrooms 1 _ b. N/A 5. Is this a worst case? Yes _ 6. Conditioned floor area (W) 1D84'ft2 c. N/A 7. Glass area & type _ a. Clear - single pane 67.0 ft2 _ 13. Heating systems b. Clear - double pane 0.0 ft2 _ a. Electric Strip c. Tint/other SC/SHGC - single pane 0.0 ft2 _ d. Tint/other SC/SHGC - double pane 0.0 ft2 b. N/A 8. Floor types _ a. Slab -On -Grade Edge Insulation R=0.0, 78.0(p) ft _ c. N/A b. N/A _ c. N/A 14. Hot water systems 9. Wall types _ a. Electric Resistance a. Frame, Wood, Exterior R=3.0, 110.0 ft2 _ b. Concrete, Int Insul, Adjacent R=3.0, 309.0 ft2 _ b. N/A c. N/A _ d. N/A _ c. Conservation credits e. N/A (HR-Heat recovery, Solar 10. Ceiling types _ DHP-Dedicated heat pump) a. N/A _ 15. HVAC credits b. N/A _ (CF-Ceiling fan, CV -Cross ventilation, c. N/A HF-Whole house fan, 11. Ducts _ PT -Programmable Thermostat, a. Sup: Con. Ret: Con. AH: Interior Sup. R=4.2, 40.0 ft _ RB-Attic radiant barrier, b. N/A MZ-C-Multizone cooling, MZ-H-Multizone heating) Glass/Floor Area: 0.06 Total as -built points: 9935.40 ~ PASS Total base points: 11767.00 I hereby certify that the plans and specifications covered by this calculation are in compliance with the Florida Energy Code. PREPARED BYAIA-d 4-d ic DATE: I hereby certify that this building, as designed, is in compliance with the Florida Ener o OWNER/AGENT: DATE: Cap: 26.0 kBtu/hr SEER: 10.00 Cap: 17.0 kBtu/hr _ COP: 1.00 Cap: 40,0 gallons EF: 0.89 Review of the plans and AU ST9T specifications covered by this ° _ _ '.VA. calculation indicates compliance �,,,°''� " _ with the Florida Energy Code. Before construction is completed this building will be inspected for �. compliance with Section 553.908 icon Florida Statutes. we'``�y� BUILDING OFFICIAL: DATE: EnergyGauge® (Version: FLRCNA-200) FORM 60OA-97 SUMMER CALCULATIONS Residential Whole Building Performance Method A - Details I ADDRESS:, PORT ST LUCIE, FL, PERMIT #: I BASE AS -BUILT "GLASS TYPES .18 X Conditioned X BSPM = Points Overhang Floor Area Type/SC Ornt Len Hgt Area X SPM X SOF = Points 18 1084.0 42.08 8210.2 Single, Clear E 1.0 5.5 20.0 59.31 0.96 1141.9 Single, Clear E 1.0 5.5 27.0 59.31 0.96 1543.6 Single, Clear E 1.0 5.5 20.0 59.31 0.96 1143.4 As -Built Total: 67.0 3828.8 1NALL TYPES Area X BSPM = Points Type R-Value Area X SPM = Points .Adajcent 309.0 0.7 216.3 Frame, Wood, Exterior 3.0 110.0 4.64 510.7 Exterior 110.0 1.90 209.0 Concrete, Int Insul, Adjacent 3.0 309.0 0.70 216.3 Base Total: 419.0 425.3 As -Built Total: 419.0 727.0 DOOR TYPES Area X BSPM = Points Type Area X SPM = Points Adjacent 21.0 1.60 33.6 Adjacent Wood 21.0 2.40 50.4 Exterior 0.0 0.00 0.0 Base Total: 21.0 33.6 As -Built Total: 21.0 50.4 CEILING TYPES Area X BSPM = Points Type R-Value Area X SPM = Points Under Attic 0.0 0.00 0.0 Base Total: 0.0 0.0 As -Built Total: 0.0 0.0 FLOOR TYPES Area X BSPM = Points Type R-Value Area X SPM = Points Slab 78.0(p) -31.8 -2480.4 Slab -On -Grade Edge Insulation 0.0 78.0(p) -31.90 -2488.2 Raised 0.0 0.00 0.0 Base Total: -2480.4 As -Built Total: -2488.2 INFILTRATION Area X BSPM = Points Area X SPM = Points 1084.0 14.31 15512.0 1084.0 14.31 15512.0 Summer Base Points: 21700.7 Summer As -Built Points: 17630.1 Total Summer X System = Cooling Total X Cap X Duct X System X Credit = Cooling Points Multiplier Points Component Ratio Multiplier Multiplier Multiplier Points 17630.1 1.000 0.930 0.341 1.000 5591.0 21700.7 0.3577 7762.3 17630.1 1.00 0.930 0.341 1.000 5591.0 EnergyGaugeTm DCA Form 60OA-97 FORM 60OA-97 WINTER CALCULATIONS Residential Whole Building Performance Method A - Details ADDRESS:, PORT ST LUCIE, FL, PERMIT #: BASE AS -BUILT GLASS TYPES .18 X Conditioned X BWPM = Points, Overhang Floor Area Type/SC Ornt Len Hgt Area X WPM X WOF = Points .18 1084.0 4.79 934.5 Single, Clear E 1.0 5.5 20.0 9.96 1.01 201.2 Single, Clear E 1.0 5.5 27.0 9.96 1.01 271.6 Single, Clear E 1.0 5.5 20.0 9.96 1.01 201.2 As -Built Total: 67.0 674.0 'WALL TYPES Area X BWPM = Points Type R-Value Area X WPM = Points Adajcent 309.0 1.8 556.2 Frame, Wood, Exterior 3.0 110.0 4.96 545.3 Exterior 110.0 2.00 220.0 Concrete, Int Insul, Adjacent 3.0 309.0 2.30 710.7 Base Total: 419.0 776.2 As -Built Total: 419.0 1256.0 DOOR TYPES Area X BWPM = Points Type Area X WPM = Points Adjacent 21.0 4.00 84.0 Adjacent Wood 21.0 5.90 123.9 Exterior 0.0 0.00 0.0 Base Total: 21.0 84.0 As -Built Total: 21.0 123.9 CEILING TYPES Area X BWPM = Points Type R-Value Area X WPM = Points Under Attic 0.0 0.00 0.0 Base Total: 0.0 0.0 As -Built Total: 0.0 0.0 FLOOR TYPES Area X BWPM = Points Type R-Value Area X WPM = Points Slab 78.0(p) -1.9 -148.2 Slab -On -Grade Edge Insulation 0.0 78.0(p) 2.50 195.0 Raised 0.0 0.00 0.0 Base Total: -148.2 As -Built Total: 195.0 INFILTRATION Area X BWPM = Points Area X WPM = Points 1084.0 -0.28 -303.5 1084.0 -0.28 -303.5 Winter Base Points: 1343.0 Winter As -Built Points: 1946.4 Total Winter X System = Heating Total X Cap X Duct X System X Credit = Heating Points Multiplier Points Component Ratio Multiplier Multiplier Multiplier Points 1945.4 1.000 0.930 1.000 1.000 1809.2 1343.0 1.0730 1441.1 1945.4 1.00 0.930 1.000 1.000 1809.2 EnergyGaugeTm DCA Form 60OA-97 FORM 60OA-97 WATER HEATING & CODE COMPLIANCE STATUS Residential Whole Building Performance Method A - Details ADDRESS:, PORT ST LUCIE, FL, PERMIT #: BASE AS -BUILT 'WATER HEATING Number of X Multiplier = Total Tank EF Number of X Tank X Multiplier X Credit = Total Bedrooms Volume Bedrooms Ratio Multiplier 1 2564.00 2564.0 40.0 0.89 1 1.00 2535.19 1.00 2535.2 As -Built Total: 2535.2 CODE COMPLIANCE STATUS BASE AS -BUILT Cooling + Heating + Points Points Hot Water Points = Total Points Cooling Points + Heating + Hot Water = Total Points Points Points 7762.3 1441.1 2564.0 11767.4 5591.0 1809.2 2535.2 9935.4 PASS EnergyGaugeTm DCA Form 60OA-97 FORM 60OA-97 Code Compliance Checklist Residential Whole Building Performance Method A - Details ADDRESS: , PORT ST LUCIE, FL, PERMIT #: 6A-21 INFILTRATION REDUCTION COMPLIANCE CHECKLIST COMPONENTS SECTION REQUIREMENTS FOR EACH PRACTICE CHECK Exterior Windows & Doors 606.1.ABC.1.1 Maximum:.3 cfm/s .ft. window area; .5 cfm/s .ft. door area. Exterior & Adjacent Walls 606.1.ABC.1.2.1 Caulk, gasket, weatherstrip or seal between: windows/doors & frames, surrounding wall; foundation & wall sole or sill plate; joints between exterior wall panels at corners; utility penetrations; between wall panels & top/bottom plates; between walls and floor. EXCEPTION: Frame walls where a continuous infiltration barrier is installed that extends from and is sealed to the foundation to the top plate. Floors 606.1.ABC.1.2.2 Penetrations/openings >118" sealed unless backed by truss or joint members. EXCEPTION: Frame.floors where a continuous infiltration barrier is installed that is sealed to the pedmeter, penetrations and seams. Ceilings 606.1 ABC.1.2.3 Between walls & ceilings; penetrations of ceiling plane of top floor; around shafts, chases, soffits, chimneys, cabinets sealed to continuous air barrier; gaps in gyp board & top plate; attic access. EXCEPTION: Frame ceilings where a continuous infiltration barrier is installed that is sealed at the perimeter, at penetrations and seams. Recessed Lighting Fixtures 606.1.ABC.1.2.4 Type IC rated with no penetrations, sealed; or Type IC or non -IC rated, installed inside a sealed box with 1/2" clearance & 3" from insulation; or Type IC rated with < 2.0 cfm from conditioned space, tested. Multi -story Houses 606.1.ABC.1.2.5 Air barrier on perimeter of floor cavity between floors. Additional Infiltration reqts 606.1.ABC.1.3 Exhaust fans vented to outdoors, dampers; combustion space heaters comply with NFPA, have combustion air. RA-99 r1T149=0 DR1=Sr'D1DTIV1= MGACI IRFC /mnc4 ho mo4 nr ovraarlarl by all racirlancac 1 COMPONENTS SECTION REQUIREMENTS CHECK Water Heaters 612.1 Comply with efficiency requirements in Table 6-12. Switch or clearly marked circuit breaker electric or cutoff as must be provided. External or built-in heat trap required. Swimming Pools & Spas 612.1 Spas & heated pools must have covers (except solar heated). Non-commercial pools must have a pump timer. Gas spa & pool heaters must have a minimum thermal efficient of 78%. Shower heads 612.1 Water flow must be restricted to no more than 2.5 gallons per minute at 80 PSIG. Air Distribution Systems 610.1 All ducts, fittings, mechanical equipment and plenum chambers shall be mechanically attached, sealed, insulated, and installed in accordance with the criteria of Section 610. Ducts in unconditioned attics: R-6 min. insulation. HVAC Controls 607.1 Seperate readily accessible manual or automatic thermostat for each system. Insulation 604.1, 602.1 Ceilings -Min. R-19. Common walls -Frame R-11 or CBS R-3 both sides. Common ceiling & floors R-11. Y EnergyGaugeTm DCA Form 60OA-97 EnergyGauge®/FlaRES'97 FLRCNA-200 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE SCORE* = 85.2 The higher the score, the more efficient the home. 1. New construction or existing 2. Single family or multi -family 3. Number of units, if multi -family 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned floor area (ft2) 7. Glass area & type a. Clear - single pane b. Clear - double pane c. Tint/other SC/SHGC - single pane • d. Tintlother SC/SHGC - double pane 8. Floor types a. Slab -On -Grade Edge Insulation b. N/A c. N/A 9. Wall types a. Frame, Wood, Exterior b. Concrete, Int Insul, Adjacent c. N/A d. N/A e. N/A 10. Ceiling types a. N/A b. N/A c. N/A 11. Ducts a. Sup: Con. Ret: Con. AH: Interior b. N/A RICH PROPERTIES,, PORT ST LUCIE, FL, New _ 12. Cooling systems Multi -family _ a. Central Unit 1 1 _ b. N/A Yes _ c. N/A 67.0 ft2 _ 13. Heating systems 0.0 ft2 _ a. Electric Strip 0.0 ft2 _ 0.0 ft2 b. N/A R=0.0, 78.0(p) ft _ c. N/A 14. Hot water systems _ a. Electric Resistance R=3.0, 110.0 ft2 R=3.0, 309.0 ft2 _ b. N/A _ c. Conservation credits (ER -Heat recovery, Solar _ DHP-Dedicated heat pump) _ 15. HVAC credits _ (CF-Ceiling fan, CV -Cross ventilation, HF-Whole house fan, _ PT -Programmable Thermostat, Sup. R=4.2, 40.0 ft _ RB-Attic radiant barrier, MZ-C-Multizone cooling, MZ-H-Multizone heating) I•certify that this home has complied with the Florida Energy Efficiency Code For Building . Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature: Address of New Home: Date: City/FL Zip: Cap: 26.0 kBtu/hr SEER: 10.00 Cap: 17.0 kBtu/hr _ COP: 1.00 Cap: 40.0 gallons EF: 0.89 *NOTE. The home's estimated energyperformance score is only available through the FLARES computer program. This is not a Building Energy Rating. If your score is 80 or greater (or 86 for a US EPADOE EnergyStar'designation), your home may qualms for energy efficiency mortgage (EEA1) incentives ifyou obtain a Florida Energy Gauge Rating. Contact the Energy Gauge Hotline at 4071638-1492 or see the Energy Gauge web site at www.fsec. ucf edu for information and a list of certified Raters. For information about Florida's Energy Efficiency Code For Building Construction, contact the Department of Community Affairs at 8501487-1824. - . EnergyGauge® (Version: FLRCNA-200) r u, % RIGHT-J LOAD AND EQUIPMENT SUMMARY Entire House FES, INC. Job: 01089 4/21/99 34 N.W. 168TH. STREET, NORTH MIAMI BEACH, FL 33169 Phone: 305-653-0212 Fax: 305-653-0232 For: SAVANNA CLUB APT PLANCB2 BOT.; FL Phone: WC=e Notes: Weather: Fort Lauderdale, FL, US Winter Design Conditions Outside db 46 OF Inside db 71 OF Design TD 25 OF Heating Summary , Building heat loss 9484 Btuh Ventilation air 0 cfm Ventilation air loss 0 Btuh Design heat load 9484 Btuh Infiltration Method Simplified Construction quality Average Fireplaces 0 Heating_ __ Cooling Area (ft2) �084 084�3 Volume (ft') 9756 9756 Air changes/hour 1.0 0.5 Equiv. AVF (cfm) 163 81 Heating Equipment Summary Make n/a Trade n/a ' Efficiency 100.0 EFF Heating input 0 Btuh Heating output 0 Btuh Heating temp rise 0 OF Actual heating fan 443 cfm • Heating air flow factor 0.047 cfm/Btuh Space thermostat Summer Design Conditions Outside db 91 OF Inside db 75 OF Design TD 16 OF Daily range M , Relative humidity 50 % Moisture difference 60 gr/lb Sensible Cooling Equipment Load Sizing Structure 10230 Btuh Ventilation 1760 Btuh Design temperature swing 3.0 OF Use mfg. data n Rate/swing multiplier 0.96 Total sens. equip. load 11510 Btuh Latent Cooling Equipment Load Sizing Internal gains 690 Btuh Ventilation 4064 Btuh Infiltration 3311 Btuh Total latent equip. load 8065 Btuh Total equipment load 19575 Btuh Cooling Equipment Summary Make Trade Efficiency 0.0 EER Sensible cooling 0 Btuh Latent cooling 0 Btuh Total cooling 0 Btuh Actual cooling fan 443 cfm Cooling air flow factor 0.043 cfm/Btuh Load sensible heat ratio 60 % Printout certified by ACCA to meet all requirements of Manual J 7th Ed. ,. Wriigj ltr!.c3 t Right -Suite ResidentialTM 5.0.45 RSR23656 2001-Jul-05 12:00:28 � HAWrightsoft LOAD CALCS\SAVANNA CLUBXPLAN B2 BOT.rsr Page 1 oil Sr 1 S oW �5r Ow DO n0 p W ZD4o DCl) c om cz r0 D N za N W OC 00 N c CA N W N W 088 J tD O A W N -+ O CO co J M CT M4 X A W N D-IOrrtn 10rrfA o_cwmc g �o v; o CDZO w Z wwxm O O ow-r2 =C mw 'o i TG) ww_x moww �ocmmc N _, " N O CD �• N O. C N �. (n f0 CyP tZi M13 W rn v Q 7 c: y y � C, N N O m (O 3 CD C '� N �' y vOi N 61 N 0' CD N a y >> �, (n 0. n' O O O N O O H 7 7 d N o. y 0 C -II y O; O Z -+...� C CD 2 N fD y N O.� N y O p 7 3 y X 0 O w= w N 7 O M j ID' w co a a m• 0 3 C rn '^ fD O. O v w "" N C1 0 CS w �` N O. O Q w O CJ w ZZ '^ N CS n C7 w 'O CD a 0 Cr w �� OJ A g P° O• n' W =JvCD CO n mpm W@ ± a v 0z0E Do2fnlA agyZ= ZOD OM -n3 r ^ cn N N N = N N O O O O O O A O 0 0 0 0 0 O O O N W O A 0 0 0 0 01 0 O O O N W fG 'O W '0OOG O w W 00066 W OOM.P W M 0001 0O(OA Ca 0 = p 7 00 O 0000 CD OOOOON OO-r0�� OO (D 000000 S : S : r x 00"0"-+ 0 O W COOONO 00000-+ OOQO W, OOO OOO CO 00 C Q a 0 m m +�00 TS S `% m O i i : i: N W w •tO 0 0 e �W O co () V 00000 co 000000 O O OOOCOO N 00 .N.� W 000 V 00 CD OOOOOJ W W A 0000 V CA - ,y1 Cp A �xx :xr A A A C1i 1+NV N x ::xx V x xxi tOO. aoCD O W Go OD A 0 0 0 A O 0 0 0 p p O 0 0 0 0 0 0 P O O O CT coO O O N O O O O O O C 8 8x 'a v Co A N N NCO i N 8 W 8 v O. A W C.)O O (A OOOO OOO W A OOOOOO 000000 OO CD 000OAA OO CO A C OOCD OO CD O » O O _ W A w 0 p 0 0 �W O \ coW V 00000 CD OOOOp O 8 00. COO M N 00� (D 000SS J as (D 000OGV W Op OO V Z x N x CD `' O C. .N -CD ZA A A A A » r r � r �i i CD OOi O �j CD Cl) AOOO.P. m O OOO O OO OO OOOO O OO OI CD O OO N CD CD 0 000 W O O_A x $ x» x» x S x x x x to w O A A 00 W 0 0 0 0 0 0 0 A 0 0 0 0 0 0 O O O O O O O O O O O CCD O O O CAD 0 0 w � ss� SS ss SS 92 93 � � � � x x x � x r � :I] Y x x ♦ ♦ • ♦ .I ka s RIGHT-J CALCULATION PROCEDURES A, B, C, D Entire House FES, INC. Job: 01089 4/2V99 34 N.W. 168TH. STREET, NORTH MIAMI BEACH, FL 33169 Phone: 305-653-0212 Fax: 305-653-0232 Procedure A - Winter Infiltration HTM Calculation* 1. Winter infiltration AVF 1.0 ach x 9756 ft3 x 0.0167 = 163 cfm 2. Winter infiltration load 1.1 x 163 cfm . x 25 OF Winter TD = 4480 Btuh 3. Winter infiltration HTM 4480 Btuh / 88 ft2 Total window = 50.9 Btuh/ft2 and door area Procedure B - Summer Infiltration HTM Calculation 1. Summer infiltration AVF 0.5 ach x 9756 ft3 x 0.0167 = 81 cfm 2. Summer infiltration load 1.1 x 81 cfm x 16 OF Summer TD = 1434 Btuh 3. Summer infiltration HTM 1434 Btuh / 88 ft2 Total window = 16.3 Btuh/ft2 and door area Procedure C - Latent Infiltration Gain 0.68 x 60 gr/lb moist.diff. x 81 cfm = 3311 Btuh Procedure D - Equipment sizing toads 1. Sensible sizing load Sensible ventilation load 1.1 x 100 cfm vent. x 16 OF Summer TD = 1760 Btuh Sensible load for structure (Line 19) + 10230 Btuh Sum of ventilation and structure loads = 11990 Btuh Rating and temperature swing multiplier x 0.96 Equipment sizing load - sensible = 11510 Btuh 2. Latent sizing load Latent ventilation load 0.68 x 100 cfm vent. x 60 gr/lb moist.diff. _ . 4064 Btuh Internal loads = 230 Btuh x 3 people + 690 Btuh Infiltration load from Procedure C + 3311 Btuh Equipment sizing load - latent = 8065 Btuh *Construction Quality is: a No. of Fireplaces is:, 0 Bol0talic values have been manually overridden Printout certified by ACCA to meet all requirements of Manual J 7th Ed. ASF.. Wr-jglhtSOft Right -Suite Residential*"' 5.0.45 RSR23656 2001-Jul-05 12:00:28 /4CACK HAWrightsoft LOAD CALCS\SAVANNA CLUB\PLAN B2 BOT.rsr Page 1