ENGINEER EVALUATE TEST CONSULT CERTIFY'
REPORTEVALUATION
Polyglass USA, Inc. Evaluation Report 1512060.02.09-1125
1111 West Newport Center Drive FL5259-1129
Deerfield Beach, FL 33442 Date of Issuance: 02/24/2009
(954)233-1230 Revision 25: 10/14/2019
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen, P.E.for
use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described
herein have been evaluated for compliance with the 6" Edition (2017) Florida Building Code sections noted herein.
DESCRIPTION: Polyglass Roof Underlayments
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced
Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this
Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. of any changes to the
product(s), the Quality Assurance or the production facility location(s). NEMO I etc. requires a complete review of this
Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "NEMOletc. Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its
distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 16.
Prepared by:
Robert J.M. Nieminen, P.E.
-'�•..:,<�'"''
Florida Registration No. 59166, Florida DCA ANE1983 The facsimile seal appearing was authorized by Robert Nieminen,P.E.on
10/14/2019. This does not serve as an electronically signed document.
CERTIFICATION OF INDEPENDENCE:
1. NEMO Ietc. does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. NEMO I etc. is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, A.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
S. This is a building code evaluation. Neither NFMOIetc. nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
02019 NEMO ETC,LLC
ONEMOJetc.
ROOFING COMPONENT EVALUATION
1. SCOPE:
Product Category: Roofing
Sub-Category: Underlayment
Compliance Statement: Roof Underlayments, as produced by Polyglass USA, Inc., have demonstrated compliance with the
following sections of the 611 Edition (2017) Florida Building Code through testing in accordance with the following Standards,
Compliance is subject to the Installation Requirements and Limitations/Conditions of Use set forth herein.
2. STANDARDS:
Section Property Standard Year
1504.3.1 Wind Uplift FM 4474 2011
1504.3.1 Wind Uplift UL 1897 2012
1507.2.3/1507.1.1 Physical Properties ASTM D226 2009
1507.2.4/1507A.1, 1S07.2.9.2 Physical Properties ASTM D1970 2015
1507.3.3 Physical Properties FRSA/TRI April 2012 2012
1507.11.2 Physical Properties ASTM D6163 2008
1507.11.2 Physical Properties ASTM D6164 2011
1507.11.2 Physical Properties ASTM D6222 2011
1507.11.2 Physical Properties ASTM D6509 2009
TAS 110 Accelerated Weathering ASTM D4798 2011
3. REFERENCES:
imipt Examination Reference pate Entitv Examination Reference Date
ERD(TST 6049) Wind Uplift 12757.08.01-1 09/13/2001 ERD(TST 6049) Tensile adhesion P40390.04AS 04/03/2015
ERD(TST 6049) Wind Uplift 11776.06.02 01/16/2003 ERD(TST 6049) TAS 103 P44360.10.14-R1 05/18/2015
ERD(TST 60491 Wind Uplift P1740.01.07 01/04/2007 ERD(TST 6049) Wind Uplift PLYG-SC8905.05.16-1 05/17/2016
ERD(TST 60491 ASTM D1970 P5110.04.07-1 04/11/2007 ERD(TST 6049) ASTM D1970 PLYG-SC10130.06.16-1 06/27/2016
ERD(TST 60491 Wind Uplift P9260.03.08 03/21/2008 ERD(TST 6049) Tensile adhesion PLYG-SC10130.06.16-2 06/27/2016
ERR(TST 6049) Wind Uplift P30540.11.09-R1 11/10/2009 ERD(TST 60491 TAS 103 PLYG-SC10130.06.16-3 06/27/2016
ERD(TST 6049) Tensile Adhesion P11030.11.09-1 11/30/2009 ERD(TST 60491 ASTM 01970/D4798 PLYG-SC8080.07.16 07/16/2016
ERD(TST 6049) Wind Uplift P11030.11.09-2 11/30/2009 ERD(TST 604% Wind Uplfft PLYG-SC12025.10.16 10/12/2016
ERD(T5T 6049) ASTM D4977 1311030.11.09-3 11/30/2009 ERD(TST 6049) TA5 103 PLYG-503040.12.16 12/27/2016
ERD(TST 6049) ASTM D1970 P33360.06.10 06/25/2030 ERD(TST 6049) 30/90 physicals PLYG-SC11900.03.17 03/10/2017
ERD(TST 6049) TAS 103 P33370.03.11 03/02/2011 ERD(TST 6049) TAS 103 PLYG-SC12115.08.17 08/08/2017
ERD(TST 6049) Tensile Adhesion P33370.04.11 04/26/2011 ERD(TST 6049) TA5 103 PLYG-SC13035.08.17 10/31/2017
ERD(TST 6049) ASTM D1970 P37300.10.11 10/19/2011 FM(TST 1867) Wind Uplift 3004091 01/12/2000
ERD(TST 6049) TAS 103 P40390.08-12-1 08/06/2012 IMES(EVIL 2396) IBC Compliance ESR-1697 04/01/2019
ERD(TST 6049) Tensile Adhesion P40390.M12 2 08/07/2012 M-D(CER 1592) HVH2 Compliance NOA 17-0614 11 07/06f2017
ERD(TST 6049) Tensile Adhesion C41420.09.12.3 09/11/2012 MTI(TST 2508) ASTM D4798 JX20H7A 04/01/2008
ERD(TST 6049) Wind Uplift P39680.09.13 03/04/2013 NEMO(TST 6049) ASTM D1970 4-PLYG-18-004.03.18 03/29/2018
ERD(TST 6049) ASTM D1970 P45370.04.13 04/26/2013 N E M 0(TST 6049) Wind Uplift 4L-PLYG-18-003.01.19 01/11/2019
ERD(TST 60491 Wind Uplift P1738.02.07-R2 04/29/2013 NEMO(TST 6049) ASTM D6163 4S-PLYG-18-002.01.19-A 01/24/2019
ERD(TST 6049) Wind Uplift 11757.04.01.1-R1 04/30/2013 NEMO(TST 6049) ASTM 06222 4S-PLYG-18-002.05.19-C 05/20/2019
ERD(TST 6049) ASTM D6164 P37590.D3.13-3A 05/06/2013 NEMO(TST 6049) TAS 103 45-PLYG-18-004.10.19-G 10/08/2019
ERD(TST 6049) ASTM D6509 1)37590.03.13.1-R1 06/26/2013 MEMO(T5T 6049) TA5 103 4S-PLYG-18-004.10.19-1 10/08/2019
ERD(TST 6049) Wind Uplift P41630.08.13 08/06/2013 NEMO(TST 6049) TAS 103 45-PLYG-18-004.10.19-L 10/09/2019
ERD(TST 6049) A5TM D4601 P45940.09.13 09/04/2013 N E M 0(TST 6049) TAS 103 4j-PLYG-19-5SUDL-01.A 10/10/2019
ERD(TST 6049) Wind Uplift P11751.05.03-R1 11/26/2013 PRI(TST 5878) Tensile Adhesion PRIG1111 04/08/2002
ERD(TST 6049) Wind Uplift P11781.11.03-R1 11/26/2013 PRI(TST 5878) TAS 103 PUSA-018-02-01 07/14/2003
ERD(TST 6049) 30/90 physicals P45270.05.14 05/12/2014 PRI(TST 5878) TAS 103 PUSA-035-02.01 09/29/2006
ERD(TST 6049) Tensile adhesion 6020.09.14-5 09/08/2014 PRI(TST 5878) TAS 103 PU5A-055-02-02 12/10/2007
ERD(TST 60491 Tensile adhesion 6020.09.14-6 09/08/2014 PRI(TST 5878) ASTM D6222 PUSA-061-02-02 01/28/2008
ERD(TST 6049) Tensile adhesion P46520.10.14 10/03/2014 PRI(TST 5878) ASTM D6164 PUSA-088-02-01 07/29/2009
ERD(TST 6049) ASTM D1970/D4798 P43290.10.14 10/17/2014 Polyglass USA P/L Affidavit Mule-Hide Cross Ltg 03/01/2008
NEMO ETC,I.I.C. Evaluation Report P12060.02.09-11125
Cerrfficate ofAutnnrimbon V324SS 6"'EDITION(2017)FBC NON-HVHZ EVALUATION FL5259-R29
Polyglass Roof Underlayments;(954)233-1230 Revision 25:10/14/2019
Page 2 of 16
ON EMO I etc.
in-tiv Examination Reference Date Entity Examination Reference Date
ERE)(TST 6049) TAS 103 PLY&SC7550.03.15 03/24/2015 Polyglass USA Materials Affidavit Polystick Compound 08/18/2011
UL(QUA9625) Quality Control Service Confirmation 09/13/2018
4. PRODUCT DESCRIPTION:
Product Specification Plant(s) Description
4.1 Elastobase ASTM D6163 FL Fiberglass-reinforced,SBS modified bitumen base sheet
4.2 Elastobase P ASTM D6164 FL Polyester-reinforced,SBS modified bitumen base sheet
4.3 Elastoflex G TU M-D 13-004 PA Polyester-reinforced, modified bitumen tile underlayment
FRSA/TRI April 2012 composed of a sand-surfaced SBS modified bitumen back-
side and granule-surfaced APP modified bitumen top-side
4.4 Elastoflex S6 G ASTM D6164 FL Polyester-reinforced, SBS modified bitumen cap sheet
FRSA/TRI April 2012
4.5 Elastoflex S6 G FIR ASTM D6164 FL Polyester-reinforced,S135 modified bitumen cap sheet
FRSA/TRI April 2012
4.6 Mule-Hide SA-APP Cap Sheet ASTM D6222 FL Polyester-reinforced,APP modified bitumen cap sheet
FRSA/TRI April 2012
4.7 HydraGuard Dual Pro A5TM D1970 FL Nominal 60-mil thick dual-layer rubberized asphalt
waterproofing membrane,fiberglass reinforced,with a
polyester fabric surface
4.8 HydraGuard Tile Pro ASTM D1970 FL Nominal 60-mil thick dual-layer rubberized asphalt
TAS 103 waterproofing membrane,fiberglass reinforced,with a
FRSA/TRI April 2012 polyester fabric surface
4.9 Mule-Hide SA-APP Cap Sheet ASTM D6222 FL Polyester-reinforced,APP modified bitumen cap sheet
(FR) FRSA/TRI April 2012
4,10 Polyflex G ASTM D6222 FL Polyester-reinforced,APP modified bitumen cap sheet for
FRSA/TRI April 2012 use as an alternate to Heat Applied "Cap Sheet" in the
"Two Ply System"from FRSA/TRI April 2012(04-12)
beneath mechanically fastened or adhered tile roof
systems
4.11 Polyflex G FIR ASTM 06222 FL Polyester-reinforced,APP modified bitumen cap sheet for
FRSA/TRl April 2012 use as an alternate to Heat Applied "Cap Sheet"in the
"Two Ply System"from FRSA/TRI April 2012 (04-12)
beneath mechanically fastened tile roof systems
4.12 Polyflex SA P ASTM D6222 FL Polyester-reinforced,APP modified bitumen cap sheet
FRSA/TRI April 2012
4.13 Polyflex SA P FIR ASTM D6222 FL Polyester-reinforced,APP modified bitumen cap sheet
FRSA/TRI April 2012
4.14 Polyglass Base ASTM D6509 FL Fiberglass-reinforced,APP modified bitumen base sheet
4.15 Polyglass G2 ease Sheet ASTM D4501 AL Fiberglass-reinforced, asphaltic base sheet
4.16 Polystick IR-Xe ASTM D1970 FL, PA Nominal 60-mil thick rubberized asphalt waterproofing
membrane,glass fiber reinforced,with an aggregate
surface
4.17 Polystick MTS Plus TAS 103 FL, PA,TX Nominal 60-mil thick rubberized asphalt waterproofing
FRSA/TRI April 2012 membrane,glass fiber reinforced,surfaced with
polyolefinic film surface
NEW ETC,LLC. Evaluation Report P12060.02.09-R25
Certificate of Authorization 432455 6TN EDITION(2017)FSC NON-HVHZ EVALUATION FL5259-R29
Polyglass Roof Underlayments;(954)233-1230 Revision 25;10/14/2019
Page 3 of 16
OMEMO f etc.
4. PRODUCT DESCRIPTION:
Product Specification Plant(s) Description
4.18 Polystick MU-X ASTM D1970 FL, NV, PA Nominal 54-mi4 thick dual-layer rubberized asphalt
(See Section 5.8) waterproofing membrane,fiberglass reinforced,with a
polypropylene film surface
4.19 Polystick TU Max ASTM D1970 FL, PA,TX Nominal 60-mil thick rubberized asphalt waterproofing
TAS 103 membrane with a 190 g/m2 polyester fabric surface
FRSA/TRI April 2012
4.20 Polystick TU P TAS 103 TX Nominal 130-mil thick rubberized asphalt waterproofing
FRSA/TRI April 2012 membrane,glass-fiber/polyester reinforced,with a
granular surface
4.21 Polystick TU Plus ASTM 01970 FL, PA Nominal 80-mil thick rubberized asphalt waterproofing
TA5103 membrane,glass fiber reinforced,with a polyester fabric
FRSA/TRI April 2012 surface
5. LIMITATIONS:
5.1 This is a building code evaluation. Neither NEMO[etc.nor Robert Nieminen, P.E.are, in any way,the Designer of Record for any
project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless
retained specifically for that purpose,
5.2 This Evaluation Report is not for use in the HVHZ.
5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory for fire ratings of
this product.
5.4 Polyglass Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced within
FBC approval documents. If not listed, a request may be made to the Authority Having Jurisdiction for approval based on this
evaluation combined with supporting data for the prepared roof covering.
5.5 Allowable Roof Covers:
TABLE 1: ROOF COVER OPTIONS
Wood Shakes
Underlayment Asphalt Shingles Nail-On Tile Foam-On Tile Metal &Shingles Slate
Elastobase Yes Yes Yes Yes Yes Yes
(Base sheet in 2-ply system) (Base Sheet in 2-ply system)
YGs Yes
Elastohase P Yes (Base Sheet n 2-ply system) (Base Sheet in 2-ply system) Yes Yes Yes
Polyglass Base No Yes Yes No No No
(Base sheet in 2-ply system) (Base Sheet in 2-p1y system(
Polyglass G2 Base No Yes Yes No No No
{Base Sheet in 2-ply system) {Base Sheet in 2-ply system)
Elastoflex G TU Yes Yes Yes (See 5.5.1) No Yes Yes
Elastoflex S6 G Yes Yes Yes (See 5.5.1) No Yes Yes
Elastoflex S6 G FR Yes Yes No No Yes Yes
HydraGuard Dual Pro Yes No No Yes Yes Yes
HydraGuard Tile Pro Yes Yes Yes {See 5.5.1) Yes Yes Yes
Mule-Hide SA-APP Cap
Yes Yes Yes (See 5.5.1) No Yes Yes
Sheet
Mule-Hide SA-APP Cap
Sheet(FR) Yes Yes Yes (See 5.5.1) No Yes Yes
Polyflex G Yes Yes Yes (See 5.5.1) No Yes Yes
Polyflex G FR Yes Yes No No Yes Yes
Polyflex SA P Yes Yes Yes (See 5.5.1) No Yes Yes
Polyflex 5A P FR Yes Yes Yes (See 5.5.1) No Yes Yes
Polystick IR-Xe Yes No No No Yes Yes
NEMO ETC,LLC. Evaluation Report P12060.02.09-R25
Certificate of Authori2ation#32455 6'"EOITION(2017)FBC NON-HVHI EVALUATION FL5259-R29
Polyglass Roof Underlayments;1954)233-1230 Revision 25:10/14/2019
Page 4 of 16
ONEMOjetc.
TABLE 1. ROOF COVER OPTIONS
Wood Shakes
Underlayment Asphalt Shingles Nall-On Tile Foam-On Tile Metal &Shingles Slate
Polystick MTS Pius Yes Yes No Yes Yes Yes
Polystick MU-X Yes No No Yes Yes Yes
Polystick TU Max No Yes Yes (See 5.5.1) Yes No No
Polystick TU P No Yes Yes (See 5.5.11 No No No
PolystickTU Plus Yes Yes Yes (See 5.5.1) Yes Yes Yes
5.5.1 "Foam-On Tile" is limited to use of the following Approved tile adhesives/underlayment combinations.
TABLE IA:ALLOWABLE TILE ADHESIVE/UNDERLAYMENT COMBINATIONS)
Florida Product
Adhesive Approval Underlayments
DAP Foam Touch'n Seal StormBond FL14506 Polystick TU Max or Polystick TU Plus
Roof Tile Adhesive
Dow TileBondT" FL22525 HydraGuard Tile Pro,Polyflex SA P,Polystick TU Max,Polystick TU P or
Polystick TU Plus
Elastoflex G TU,Elastoflex S6 G,HydraGuard Tile Pro,Mule-Hide SA-APP
ICP Adhesives Polysete AH-160 FL6332 Cap Sheet,Mule-Hide SA-APP Cap Sheet(FR), Polyflex G,Polyflex SA P,
Polyflex SA P FR,Polystick TU Max,Polystick TU P or Polystick TU Plus
Elastoflex S6 G, HydraGuard Tile Pro,Mule-Hide SA-APP Cap Sheet,Mule-
ICP Adhesives Polysete RTA-1 FL6276 Hide SA-APP Cap Sheet(FR),Polyflex G, Polyflex SA P,Polyflex SA P FR,
Polystick TU Max,Polystick TU P or Polystick TU Plus
5.6 Allowable Substrates:
TABLE 2: SUBSTRATE OPTIONS FOR ADHERED UNDERLAYMENTS
Underlayment Application Substrates(designed to meet wind loads for project)
Type Primer Material(s)
Deck// (Optional)ASTM D41 plywood,OSB,Southern Yellow Pine or Huber
HydraGuard Dual Pro, Engineered Woods"ZIP System"Panels
HydraGuard Tile Pro, sheathing
ASTM D41 structural concrete
Polystick(all variations), self- ASTM C1289 Type Il Class 1 polyisocyanurate,ASTM
Mule-Hide SA-APP Cap adhering Insulation (Optional)ASTM D41 C1289 Type V polyisocyanurate-composite,DensDeck
Sheet,Mule-Hide SA-APP or WB-3000
Cap Sheet(FR),Polyflex Prime or SECUROCK Gypsum Fiber Roof Board
SA P or Polyflex SA P FR Base A5TM D226 felt,Elastobase,Elastobase P or Mule-Hide
Sheet N/A Nail Base
Deck ASTM D41 structural concrete
Elastoflex G TU,Elastoflex hot asphalt Insulation (Optional)ASTM D41 DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board
S6 G or Elastoflex 56 G FR Base ASTM D226 felt,Elastobase,Elastobase P,Mule-Hide Nail
Sheet NSA Base or Polyglass G2 Base
Deck ASTM D41 structural concrete
Polyflex G or Polyflex G FR torch- Insulation (Optional)ASTM D41 DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board
applied Base N/A Elastobase,Elastobase P,Mule-Hide Nail Base,Polyglass
Sheet G2 Base or Polyglass Base
Refer to Tile Manufacturer's orAdhesive Manufacturer's Florida Product Approval for Overturning Moment Resistance Performance.
MEMO ETC,I.I.C. Evaluation Report P12060.02.09-R25
Certificate of Aurhorazition N32455 6T"EDITION(2017)FBC NON-HVHZ EVALUATION FL5259-R29
Polyglass Roof Underlayments;(954)233-1230 Revision 25:10/14/2019
Page 5 of 16