HomeMy WebLinkAboutEngineering Architectonic Inc
November 5,2020
St. Lucie County Building Department Planning& Development Services
Building&Code Regulation Division
2300 Virginia Avenue RECEIVED
Ft. Pierce, FL 34982 5 2020
Permitting Department
RE: Nettles Island Inc. St. Lucie County
9801 S.Ocean Dr.Jenson Beach, FL 34957
Nettles Island Ocean Pool Pump Room Storage Closet
To Whom It May Concern:
Our office has performed design pressure calculations for the above referenced project and herby certify
that the proposed Fiberglass Door is incompliance with the 2017 Florida Building Code, 165 mph wind
zone, exposure "D", risk category II.
Exposure"C" Multiplier for 15' mean roof height is 1.29
Wind Zone 4 28 x 1.29=36.12
Wind Zone 5 34 x 1.29=43.86
Required Design Pressures: +/-43.86
Product:Fiberglass Door, FL#17184.5, Plastpro
Product Pressures: +/-50
QF
ctfUl 'pmitt d,
�1® Micha'IFSggl,A I A®�
n°AR96 8 m°� File Co
�'A�chit ��oraic• Inc.
806 Delaware Avenue Tel: 772 460 7751 www.architectonicinc.com
Fort Pierce, Florida 34950 Fax: 772 460 4244 FL Reg#AA26003348 1 of 1