HomeMy WebLinkAboutEngineering Architectonic Inc November 5,2020 St. Lucie County Building Department Planning& Development Services Building&Code Regulation Division 2300 Virginia Avenue RECEIVED Ft. Pierce, FL 34982 5 2020 Permitting Department RE: Nettles Island Inc. St. Lucie County 9801 S.Ocean Dr.Jenson Beach, FL 34957 Nettles Island Ocean Pool Pump Room Storage Closet To Whom It May Concern: Our office has performed design pressure calculations for the above referenced project and herby certify that the proposed Fiberglass Door is incompliance with the 2017 Florida Building Code, 165 mph wind zone, exposure "D", risk category II. Exposure"C" Multiplier for 15' mean roof height is 1.29 Wind Zone 4 28 x 1.29=36.12 Wind Zone 5 34 x 1.29=43.86 Required Design Pressures: +/-43.86 Product:Fiberglass Door, FL#17184.5, Plastpro Product Pressures: +/-50 QF ctfUl 'pmitt d, �1® Micha'IFSggl,A I A®� n°AR96 8 m°� File Co �'A�chit ��oraic• Inc. 806 Delaware Avenue Tel: 772 460 7751 www.architectonicinc.com Fort Pierce, Florida 34950 Fax: 772 460 4244 FL Reg#AA26003348 1 of 1