HomeMy WebLinkAboutEngineering RECEIVED NOV 0 6-2020 . City of Port. Saint Lucie Permitting Department St, Lucie County Building Department RESIDENTTL&L ENGINEER/ARCHITECT LETTER OF COMPLIANCE 1 DATE: October 28,2020 `} PERII/1IT 1 I NAME. Scott R. Sanders ADDRESS: 101 Ridge Place,Port St.Lucie I have personally inspected The new metal roof and underlayment (Description of work- performed) at the above named address. Applicable items including but not limited to are Structural, Electrical, Plumbing, Mechanical Components and the system's are in compliance with the F,loxidaiRes�denti.al Cade 6th Edition (2017). t S a g.' t (St afure of Enb�ncer/Ar�chitOct) S � seal and sin tyre - Revised 06t28f2016 uv ' - Southeast Building Engineers, LLC 3578 Rolling Acres Road I JEBE.,.1.0 Pace, FL 32571 RECEIVED 772-774-go86 r<o G_L Gv' s.sanders@sebeningeers.com NOV 0 6`2020 Permitting Department St. Lucie County October 28,2020 City of Port St.Lucie Building Department 121 SW Port St Lucie Blvd. Port St Lucie,FL 34984 Subiect: Roof Installation Certification 101 Ridge Place Port St.Lucie,FL To Whom It May Concern: This firm was retained to certify the installation of a"5V"crimp metal roofing that was completed without having required intermediate inspections at the above referenced project.This report and all statements are based on orL-site inspection of randomly chosen section,photo and/or video documentation taken during installation,paid invoices, and delivery receipts provided by the owner,Mr.Steven M.Trempe. Our findings are as follows: Project Design Criteria: 160 MPH Wind Speed Exposure"C" Roof Hieght<30'-0" Internal Pressure Coefficient 0.18 Roof slope<6:12 a=3'-0" Documentation: Mr.Trempe proved to our satisfaction that they did indeed utilize"5V"Crimp metal roofing manufactured by Extreme Metal Fabricators,LLC(installation governed by product approval FL 17022.1),and Ultra HT Wind& Water Seal underlayment manufactured by MFM Building Products Corp.(installation governed by product approval NOA 18-1015.01)delivered to the site to cover the project's roof. We were provided photographs sufficient to verify the following Construction: I. Wood Plank Decking !wry We verified existing lx6 wood plank decking was free of damage and was re- nailed throughout with a minimum of(3)10d ringshank nails @ each truss bearing. f lF / F ,\ Page 112 u . Southeast Building Engineers, LLC 3578 Rolling Acres Road (SEBE.Lt.0 Pace, FL 32571 772-774-9o86 l tee`' s.sanders@sebeningeers.com II. Underlavment We found that Ultra HT Wind&Water Seal underlayment was installed that utilizes a self-adhered fastening system. There was no unexplained stretching, ' bubbling,wrinkling,and/or tears with all proper edge/end lapping maintained. As such we are certifying that the underlayment was properly installed. III. "5V"Metal Panels We verified the use of 5V"Crimp metal roofing manufactured by Extreme Metal Fabricators,LLC and fastened with#1Ox1-1/2"wood screws w/sealing washers z with row spacing of 16"o.c.and @ 12"o.c along panel width. Final Findings: All inspected areas of work were installed in accordance with the 2017 Florida Building Code 61 Edition,all product approvals,and in compliance with acceptable construction practices. All fastening is compliant with the design pressure determined by this firm. Therefore,we hereby certify the installation of the"5V"metal roof panels and all required components meet or exceed all requirements of the 2017 Florida Building Code 61 Edition. Should you require any additional information or clarification,please contact me. Sincerely, a ��ScotfR Sanders-'P E 4 �-� ' - KFL teg N` ' 64781 4 a, Y 'outheast Building Engrpeers,LLC AA t f ,A Page 212