Loading...
HomeMy WebLinkAboutHelth paperwork _ f 't1S! APPLICATION #:AP12629Z2 4+` STATE OF FLORIDA PERMIT #.56-SF-1719598 DEPARTMENT OF HEALTH DOCUMENT #:F11164545 ONSITE SEWAGE' TREATMENT AND DISPOSAL SYSTEM CONSTRUCTION INSPECTION AND FINAL APPROVAL DATE PAID,:11109/2016 FEE PAID:51.5.00 D111 RECEIPT 4:56-PID-3139448. APPLICANT: Peter&Jody Hays AGENT: Charles Paschal(Cole Construction) PROPERTY ADDRESS: TBD S Brocksmith Rd Fort Pierce, FL 34945 LOT: 2 BLOCK: SUBDIVISION: ID#: 23W-500-0003-000-5 CHECKED [X] ITEMS .ARE NOT IN COMPLIANCE WITH STATUTE. OR RULE, ANU MUST BE CORRECTED. i TANK INSTALLATION SETBACKS [ ] [01] TANK SIZE [1] 1090.00 121 483.00 [ ] [271 SURFACE' WATER 100 FT [ ] (021 TANK MATERIAL Polyethylene [ ] .[28] DITCHES, FT [ ] [03] OUTLET DEVICE [ ] [29] PRIVATE WELLS 100 FT [ ] [0.4] MULTI-CHAMBERED [ Y N 1 [ ] 130.1 PUBLIC WELLS FT [ ] [051 OUTLET FILTER Polylok PL-68 [ ] [311 IRRIGATION WELLS FT [ ] [06.] LEGEND 1, 70=143-11DC3 2. 70-143-54SC4 [ ] 1.321 POTABLE WATER 100 FT [ ] [071 WATERTIGHT [ ] [33] BUILDING FOUNDATIONS 6 FT [ 1 [08] LEVEL [ ] [34:] PROPERTY LINES 100. FT [ ] [091 DEPTH TO :LID [ ] [35] OTHER FT DRAINFIELD INSTALLATION "FILLED / MOUND SYSTEM [ ] [101' AREA (11 509.4 [2-1 SQFT [ 1 [36.] DRAINFIELD COVER' [ ] [111 DISTRIBUTION BOX HEADER X [ ] [37] SHOULDERS [ 1 (12]. NUMBER OF DRAINLINES 1. 5.00 2. [ 1 [36] SLOPES [ ] [131 DRAINLINE SEPARATION [ ] [391 STABILIZATION 03/19/2018 [ 1 [14] DRAINLINE SLOPE [ ] 1151 DEPTH OF. COVER ADDITIONAL INFORMATION [ ] 116] ELEVATION [ ABOVE / BELOW ]BM 20.00 [ ] [40] UNOBSTRUCTED AREA [ ] [17] SYSTEM LOCATION [ ] [4l] STORMWATER RUNOFF [ ] 118] DOSING PUMPS 1.00 [ ] 142) ALARMS [ } 1191 AGGREGATE SIZE j ] [43] MAINTENANCE ;AGREEMENT y } [26] AGGREGATE EXCESSIVE FINES [ ] [49] BUILDING AREA [ ] [21.] AGGREGATE DEPTh [ } 145] LOCATION CONFORMS WITH SITE PLAN FILL / EXCAVATION.MATERIAL [ ) [46] HINAL SITE GRADING; [ ] [221 FILL AMOUNT [ ] [471 CONTRACTOR MICHAEL W STUHR-(ASHTO } [, '] [2,3] FILL TEXTURE [ ] 148I OTHER INFILTRATOR Quick4 Plus EQ36 LP [ ] [24] EXCAVATION DEPTH ABANDONMENT [ ] [251 AREA REPLACED [ ] [•491 TANK PUMPED [ ] [26] REPLACEMENT MATERIAL [ ] [50] TANK CRUSHED & FILLED Comments: Corrmehts are on page 2. [ APPROVED / — St.Luce CHD DATE: 12/01/2017 CONSTRUCTION DISAPPROVED 1 ' E viroo ental Speclaiisf ri J Ingram(ENVIRONMENTAL HEALTH) FINAL SYSTEM [ APPROVED / DISAPPROVED ]: r ��- St. Lucie CHD DATE: 03/19/2018 Environmontal Spec allst 11 an J Ingram(ENVIRONMENTAL HEALTH) (Explanation of Violations on following page) DH 4016, 08/Q9 (Obsoletes all previous editions which may not be used) Incorporated: 64E=.6.003, PAC l` Page 2 of 3i EH Database v.1 1L0.1 AP1262922 EID1719596 i APPLICATION #-:.AP1262922 STATE OF FLORIDA PERMIT # 56-S'F=1719598 DEPARTMENT OF HEALTH ON SITE SEWAGE TREATMENT AND DISPOSAL SYSTEM DOCUMENT #.F1:1164545 CONSTRUCTION INSPECTION' AND FINAL APPROVAL DATE PArD:11/09/2016 FEE PAID':515:00 RECEIPT #-:56-PIQ-31-394.48 Violation Number Comment. Comments The system is sized for 3:bedrooms with a maximum occupancy of 6 persons(2 per bedroom),fora total estimated flow of,300 gpd. New ST and DT installed.Liberty 113 hp.pump.5x9.long DF. No violations,system ok,to cover.Contractor Notified.onsite.Needs final.inspection for-mound system,alarm check,and site grading. Final system approved.Contractor and building department emailed final approval. � I I 1 i i DH 4016, 08/b9 (Obs:oletes ail previous editions which may not be used) Incorporated: 64E-6.003, ,FAC Page 2 of 3 EH Database v 1 0,1 AP1262922 EID1719590