Loading...
HomeMy WebLinkAboutHealth dept permit i I t 1 Y PERMIT #:66-SF-1719598 APPLICATION #:AP 1262922 STATE OF FLORIDA DEPARTNENTiOE HEALTH DATE PAID ONSITE SEWAGE TREATMENT AND DISP FEE PAID: ` a CONSTRUCTION PERMIT Mg- ED RECEIPT #: FEB.0 3 2017 DOCUMENT #: PR1038744 CONSTRUCTION PERMIT FOR: 0 TDS New PERMITTING t.Lucie County,FL APPLICANT: Peter&Jody Hays, PROPERTY ADDRESS: TBD S Brock smith Rd Fort Pierce, FL 34945 LOT: 2 BLOCK: SUBDIVISION: PROPERTY ID #: 2317-500-0003-0 0-5 [SECTION, TOWNSHIP, RANGE, PARCEL NUMBER] [OR TAX ID NUMBER] SYSTEM MUST BE CONSTRUCTED IN ACCORDANCE WITH SPECIFICATIONS AND STANDARDS OF SECTION 381.0065, F.S., AND CHAPTER 64E-6, F.A.C. DEPARTMENT APPROVAL OF SYSTEM DOES NOT GUARANTEE SATISFACTORY PERFORMANCE FOR ANY SPECIFIC PERIOD OF TIME. ANY CHANGE IN MATERIAL FACTS, WHICH SERVED AS A BASIS FOR ISSUANCE OF THIS PERMIT, REQUIRE THE APPLICANT TO MODIFY THE PERMIT APPLICATION. SUCH MODIFICATIONS MAY RESULT IN THIS PERMIT BEING MADE NULL AND VOID. ISSUANCE OF THIS PERMIT DOES NOT EXEMPT THE APPLICANT FROM COMPLIANCE WITH OTHER FEDERAL, STATE, OR LOCAL PERMITTING REQUIRED FOR DEVELOPMENT OF THIS PROPERTY. SYSTEM DESIGN AND SPECIFICATIONS T [ 900 ] GALLONS / GPD' Septic new CAPACITY A [ ] GALLONS / GPD' N/A CAPACITY N [ ] GALLONS GREASE'I RCEPTOR CAPACITY [MAXIMUM CAPACITY SINGLE TANK:1250 GALLONS] F [ ] GALLONS DOSING TANK CAPACITY [ ]GALLONS @[ ]DOSES PER 24.HRS #Pumps [ ] ;-D [ 500 ] SQUARE FEET Drainfield new SYSTEM `'R [ ] SQUARE FEET N/A SYSTEM A, TYPE SYSTEM: [ ] STANDARD ] FILLED [s] MOUND [ ] V"t i CONFIGURATION: [ ] TRENCH [g] BED [ ] N F LOCATION OF BENCHMARK: , fnd rm"1_137673"elev 22.62 Yellow capped iron BM rod fence line E of system I ELEVATION OF PROPOSED SYSTEM SITE [ 10.001 [ INCHES FT ] [ ABOVE BELOW]BENCHMARK/REFERENCE POINT E BOTTOM OF DRAINFIELD TO BE [ 17.001 [ INCHES FT ] [ ABOVE BELOW]BENCHMARK/REFERENCE POINT L D FILL REQUIRED: [25.00] IN HES EXCAVATION REQUIRED: [ 63.001 INCHES The system is sized for 3 bedrooms i vith a maximum occupancy of 6 persons(2 per bedroom),for a total estimated flow O of 300 gpd. T The licensed contractor installing the system is responsible for installing the minimum category of tank in accordance with H s.64E-6.013(3)(0,FAC. E ' R i SPECIFICATIONS BY: Brian n am TITLE: i Environmental Specialist II APPROVED BY: TITLE: Environmental Specialis t. ucle CHD Brian J An ram DATE ISSUED: 11/15/20 6 05/15/2018 DH 4016, 08/09 (Obsoletes all previous editions which may not be used) Incorporated: 64E-6.003, FAC Page 1 of 3 v 1.1.4 AP1262922 SE1013570 y NOTICE OF RIGHTS A party whose substantial interest is affected by this order may petition for an administrative hearing pursuant to sections 120.569 and 120.57, Florida Statutes. Such proceedings are governed-by Rule 28-106, Florida Administrative Code. A petition for administrative hearing must te in writing and must be received by the Agency Clerk for the Department,within twenty-on (21) days from the receipt of this order. The address of the Agency Clerk is 4052 Bald Cypress Way, BIN A-02, Tallahassee, Florida 32399. The Agency Clerk's facsimile nurr ber is 850-413-8743. Mediation is not avail ble as an alternative remedy. Your failure to submit a petition for hearing within 21 days from receipt of this order will constitute a waiver of your right to an administrative hearing, and this order shall become a'final order'. Should this order become a final order, a party who is adversely affected by it is entitled to judicial review purc uant to Section 120.68, Florida Statutes. Review proceedings are governed by the Florida ules of Appellate Procedure. Such proceedings may be commenced by filing one cop of a Notice of Appeal with the Agency Clerk of the Department of Health and a second copy, accompanied by the filing fees required by law, with the Court of Appeal in the appropriate District Court. The notice must be filed within 30 days of rendition of the final order. St. Lucie County Health Department 5150 NW Milner Dr Port Saint Lucie, FL 34983 HEALTH PAYING ON: PERMIT*56- F-1719598 BILL Doc#:56-BID-3303916. CONSTRUCTION APPLICATION#:AP1262922 RECEIVED FROM: Cole Construction AMOUNT PAID:. $ 515.00 PAYMENT FORM: CHECK 2,591 PAYMENT DATE: 11/09/2016 MAIL TO: Peter&Jody Hays FACILITY NAME : PROPERTY LOCATION: TBD 8 Brocksmith Rd Fort Pierce,FL 34945 Lot: 2 Block: Property ID: 2317-500-0003- 00-5 EXPLANATION or DESCRIPTION: QUANTITY FEE -1 - OSTDS Construction Applicatic n and Plan Review,New 1 $ 100.00 123 -OSTDS Construction Site Evaluation 1 $ 115.00 1-26- OSTDS Construction Permit New or Mod, Amendment) 1 $ 55.00 127- OSTDS Construction System Inspection 1 $ 75.00 128- OSTDS Construction System Inspection Research Fee 1 $ 5.00 133- OSTDS Construction Reinspe ction 1 $ 50.00 -1 - Surcharge(All) 1 $ 15.00 -1 - OSTDS New Permit Surcharge 1 $ 100.00 IV RECEIVED BY: VanceMH ' � AUDIT CONTROL NO. 66-PID-3139448 56 STATE OF ELORIDA PERMIT NO. DEPARTN ENU OF HEALTH DATE PAID: ONSITE 'SE GE TREATMENT AND DISPOSAL FEE PAID: tao SYSTEM RECEIPT #: APPLICATICU FOR CONSTRUCTION PERMIT APPLICATION FOR: [v/] New System [ ] Existing System [ ] Holding Tank [ ] Innovative [ ] Repair [ ] Abandonment [ ] Temporary [ ] APPLICANT: Peter B.Hays Jr.and Jody Hays AGENT: 5 P� a ,'L y�S' tg.T•� TELEPHONE: MAILING ADDRESS: 1520 S.Bro ksmith Road,Ft.Pierce,Fl TO BE COMPLETED BY APPLICANT OR APPLICANT'S AUTHORIZED AGENT. SYSTEMS MUST BE CONSTRUCTED BY A PERSON LICENSED PURSUANT TO 489.105(3) (m) OR 489.552, FLORIDA STATUTES. IT IS THE APPLICANT'S RESPONSIBILITY TO PROVIDE DOCUMENTATION OF THE DATE THE LOT WAS CREATED OR PLATTED (MM/DD/YY) IF REQUESTING CONSIDERATION OF STATUTORY GRANDFATHER PROVISIONS. PROPERTY INFORMATION LOT: 2 BLOCK: SUBDIVISION: Hays Subdivision PLATTED: 10/7/15 PROPERTY ID #: 2317-500-0003 000-5 ZONING: AG5 I/M OR EQUIVALENT: [ No ] PROPERTY SIZE: 11.105 AcRris WATER SUPPLY: [ v/] PRIVATE PUBLIC [ ]<=2000GPD [ ]>2000GPD IS SEWER AVAILABLE AS PER 381.0065, FS? [ No ] DISTANCE TO SEWER: FT PROPERTY ADDRESS: S Brocksmith Road,Ft.Pierce DIRECTIONS TO PROPERTY: F om the intersection of The Florida Turnpike and Orange Avenue,travel west on Orange Ave. 1.8 miles+/-to Brocksmith Road,the travel south along Brocksmith Road approximatly 1 mile+/-,parcel is on the east side of Brocksmith Road BUILDING INFORMATION RESIDENTIAL [ ] COMMERCIAL Unit Type of No. of Building Commercial/Institutional System Design No -Establishment Bedrooms Area Sgft Table 1, Chapter 64E 6,. FAC 1 Single Family Residential 3 2136 300 gallons per day 2 3 4 [ ] Floor/Equipment rai as [ ] Other (Specify) SIGNATURE: DATE: l A 1 At/.- DH 4015, 08/09 (Obsoletes 31reV3.0US editions which may not be used) Incorporated 64E-6.001, FA Page 1 of 4 ' I STATE OF FLO DA APPLICATION # AP1262922 DEPARTMENT OF HEALTH PERMIT # 56-SF-1719598 ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM DOCUMENT # SE1013570 SITE EVALUAT ON AND SYSTEM SPECIFICATION APPLICANT: Peter&Jody Hays CONTRACTOR / AGENT: Cole Consiruction LOT: 2 BLOCK: SUBDIVISION: ID#: 2317-500-0003-000-5 TO BE COMPLETED BY ENGINEER, HEALTH DEPARTMENT EMPLOYEE, OR OTHER QUALIFIED PERSON. ENGINEERS MUST PROVIDE REGISTRATION NUMBER AND SIGN AND SEAL EACH PAGE OF SUBMITTAL. COMPLETE ALL ITEMS. PROPERTY SIZE CONFORMS TO SITE LAN: [X]YES [ ]NO NET USABLE AREA AVAILABLE: 11.11 ACRES TOTAL ESTIMATED SEWAGE FLOW: , 300 GALLONS PER DAY [ RESIDENCES-TABLET / OTHER-TABLE 2 ] AUTHORIZED SEWAGE FLOW: 16665.01 GALLONS PER DAY [ 1500 GPD/AcRE7 OR 2500 GPD/ACRE ] UNOBSTRUCTED AREA AVAILABLE: 5000.00 SQFT UNOBSTRUCTED AREA REQUIRED: 750.00 SQFT BENCHMARK/REFERENCE POINT LOCAT ON: fnd prm"LB7673"elev 22.62 Yellow capped iron BM rod fence line E of system ' ELEVATION OF.PROPOSED SYSTEM SI E 10.00 [ INCHES / FT ] [ ABOVE / BELOW ] BENCHMARK/REFERENCE POINT THE MINIMUM SETBACK WHICH CAN BE MAINTAINED FROM THE PROPOSED SYSTEM TO THE FOLLOWING FEATURES SURFACE WATER: 85 FT DITCHES/SWALES: 100 FT NORMALLY WET: [ ]YES [X]NO WELLS: PUBLIC: FT LIMITED USE: FT PRIVATE: 146 FT NON-POTABLE: FT BUILDING FOUNDATIONS: 5 FT PROPERTY LINES: 100 FT POTABLE WATER LINES: 100 FT SITE SUBJECT TO FREQUENT FLOODING? [ ]YES EX]NO 10 YEAR FLOODING? [ ]YES [X]NO] 10 YEAR FLOOD ELEVATION FOR SITE: FT[ MSL / NGVD ] SITE ELEVATION: FT ( MSL / NGVD SOIL PROFILE INFORMATION SITE 1 SOIL PROFILE INFORMATION SITE 2 USDA SOIL SERIES:Riviera sand USDA SOIL SERIES:Riviera sand Munsell#lColor Texture Depth Munsell#1Color Texture Depth 10YR 4/1 Sand 0 To 13 10YR 4/1 Sand 0 To 10 10YR 5/1 Sand 13 To 23 10YR 511 Sand 10 To 22 10YR 3/1 Sand 23 To 27 10YR 2/1 Sand 22 To 26 10YR 4/2 Sandy Clay Loam 27 To 60 10YR 4/2 Sandy Clay Loam 26 To 63 10YR 5/2 Loamy Sand 60 To 64 10YR 5/2 Loamy Sand 63 To 67 10YR 5/1 Sand 64 To 72 10YR 5/1 Sand 67 To 72 OBSERVED WATER TABLE: 55.00 n CHES [ ABOVE / BELOW ] EXISTING GRADE TYPE: [ PERCHED / APPARENT ] ESTIMATED WET SEASON WATER TABLE EI EVATION: 17 INCHES A ABOVE / BELOW ] EXISTING GRADE HIGH WATER TABLE VEGETATION: [ ]YES IX]NO MOTTLING: [X]YES [ ]NO DEPTH: 17.00 INCHES SOIL TEXTURE/LOADING RATE FORS STEM SIZING: Sand/0.60 DEPTH OF EXCAVATION: 63 INCHES DRAINFIELD CONFIGURATION: [ ' ] TRENCH [X] BED [ ] OTHER (SPECIFY) REMARKS/ADDITIONAL CRITERIA WSWT determined using USDA WSS and so I broings 10yr5/1 and 10yr6/1 stripping in 10yr5/1 matr x 10%with diffuse boundaries starting at 17"in SB2. SB1 10"above BM.SB2 9"above BM. Alp SITE EVALUATED BY: DATE: 11/14/2016 Ing'ra Brlan(Title:Environmental Specialist IQ(ENVIRONMENTAL HEALTH) DE 4015, 08/09 (Obsoletes previous a na which may not be used) Incorporated: 64E-6.001, FAC Page 3 of 4 AP1262922 EID1719598 v 1.0.2 %ro a Sara I Page 1 of P Site Address:S Parcel ID:2317-500-0003- Account#: 180325 Sec/Town/Range: BROCKSMITH RD 0 0-5 17/35S/39E Map ID:23/17N I Zoning:AG-5 Use Type:6000 Jurisdiction:Saint Lucie County Ownership 1 Legal Description Peter B Hays Ir HAYS SUBDIVISION(PB 71-12)LOT 2(11.105 AC- Jody Hays 483,734 SF)(OR 3892-858) 1520 S Brocksmith RD Fort Pierce,FL 34945-4403 Current Values Historical Values 3-year Just/Market: $124,616 Assessei $3,054 Year Just/Market Assessed Exemptions Taxable Exemptions: $0 Taxable $3,054 2016 $124,616 $3,054 $0 $3,054 Sale History Date Book/Page Sale Code Deed Grantor Price 07-19-2016 3892/0858 0130 TR Hays(TR)Peter B $100 02-20-2004 1922/2091 XX01 WD Hays,Peter B $100 08-14-2002 1570/1946 XX00 WD Walko,Edward M $185,000 Primary Building Information Finished Area of this building:0 SF Gross Area of this building:0 SF Exterior Data View: Roof Cover: Roof Structure: Building Type: Year Built:N/A Fram : Grade: Effective Year:2014 Primary Wall: Story Height: No.Units:0 Secondary Wall: Interior Data Bedrooms:0 A/C o:0% Electric: Primary Int Wall: Full Baths:0 Heat d%:N/A% Heat Type: Avg Hgt/Floor:0 Half Baths:0 Sprin cled%:0% Heat Fuel: Primary Floors: Total Areas h-� Finished/Under Air 0 (SF): Gross Area.(SF): 0. Land Size(acres): 11.11 Land Size(SF): 483,734 Total Building Count: 1 Special Features and Yard Items Type Qty Units Year Blt This information;is t elieved to be correct at this time but it is subject to change and is not warranted. 0 Copyri ght 2016 Saint Lucie County Property Appraiser.All rights reserved. i I ttp://www.paslc.org/RECard/ 11/9/2016 YE STATE OF FLORIDA PERMIT APPLICATION TO CONSTRUCT, REPAIR,MODIFY,OR ABANDON A WELL Permit No. _9 7 Florida Unique 10 '�rj'�'� ❑Southwest PLEASE FILL OUT ALL APPLICABLE FIELDS 0Northwest' ("Denotes Required Fields Where Applicable) P.ermltS►I ulaWns Required(See Attached) - F - O L Johns River i fietw ter wdiconrradorisresponsible(or completing outh Florida this lmmandlawor&ngthepermRappNcationforlie fi2.524 Quad No. Delineation No. ''•`pq - �. _ 0, uwannee River appmpriatede:egatedoathodtywhe2apprlcable O DEP CUPANUP Appltcetion No, y ❑Delegated Authority(If Applicable) ABOVE THIS LINE-FOR OFFICIAL USE ONLY a _ 1. e? P 'Owner,LegaLNbme if C6rporation AddressD 'City 'State 'ZIP Telaphone Number 2. -5f, c,�tSrhi!"4 � 77" ri-car,,JZI 'Weil Location-sAddres Road Name or Number,City 3. 3 S-40 Off() 3 000 -1- .Z 'Parcel 1D No.(t IN)or Alternate Key(Circle One) Lot Block Unit 4. S� 4--[�[.��� Z J Xkf I V d PI yi d/r4 Check if 62-524:❑ Yes❑ No 'Section•orrLand=Grant 'Township 'Ra ge *County s ubdivision �{� y-]� f�J/ / �//�/{ }�. �f 5. ;Zr,s}MI�S A/Jj T115,0 '�.— wx� 1//1^Jt7/i= (!a/Tl .IIhEI 'W r well Contractor 'License Number 'Tele hone Number E-mail Address 'Water Well Contractors Address City State ZIP 7. 'Type of Work: 'Construction ❑ Repair ❑ Modification[]Abandonment 8. 'Number ofProposed Wells � .Reason for Repatr. ModhcatlonorA6anlfonment 9. ;Specify Intended Uses)of Well(s):8 lly MAP Domestic Landscape Irrigation El Agricultural Irrigation ® Site Investigations ❑ Bottled Water Supply Recreation Area Irrigation Livestock Monhoring Public Water Stipply(Limited Use/DOH) Nursery Irrigation Test, JAN 2 5 20 Public Water Supply(Community or Non-Community/DEP)� CommerclaUindustrial Earth-Coupled Geothermal ❑❑❑ Class I Injection Golf Course Irrigation H, Supply HVAC Return Class V Injection:❑ Recharge ❑ CommerclaVindustrial Disposal ❑ Aquifer Storage and Recovery.❑ Drainage FDO*Lo,cfe yRemedtatic ❑ Recovery❑ AirSparge ❑ Other (Do-a-)Other (Desombe) TH 10.'Oistanw from Septic System if 5 200 ft. �Z 11.Facility Descriptton - ' 12.Estimated Start D-f3.'Estimated Well Depth 220 ft. 'Estimated Casing Depth�C? .fl. Primary asing Diameter_ _in. Open Hole: From 14.Estimated Screen Interval:From "30_To 10-0 ft. 15."Primary Casing Material: Black Steel Galvanized PVC Stainless Steel Not Cased Other. 16.Secondary Casing: Telescope Casing Liner Surface Casing Diameter in. 17.Secondary Casing Material: Black Steel Galvanized PVC Stainless Steel i her j ) 18.'Method of Construction,Repair,or Abandonment. Auger Cable Tool Jetted � Rotary Sonic ) Combination(Two or More Methods) Hand Driven(Well Point.Sand Point) iHydraull t(Direct Push) } Horizontal Drilling Plugged by Approved Method Other toescriae) 19.Proposed Grouting Interval for the Primary,Secondary,and Ad�1 'Fromo igSeal Material( Bentonite OtherFrom Tc Seal Material( Bentonite Other !: i From To Seal Material( Bentonite Neat Cement Other ) l From To Seal Material( Bentonite Neat Cement Other ) } 20.Indicate total number of existing wells on site U List number of existing unused wells on site r 21.1Is this well or any existing well or water withdr�on the owner's contiguous propertyy covered urfder a Consumptive/Water Use Permit(CUP),WUP) or CUPMIUP A�Splication Yes N If yes,complete the following:C%/WUP No.; District Well ID,No. I 22.Latitude Longitude - 5 23.Data.Obtained From: GPS Map Survey Datum: NAD 27 NAD 83 WGS�84 IbonbydetWrMIWd=qq,1aebtMepphIrabsalTaaee,FiVioaAertWstneiWCoeo.maealawatar I.Cw*U tiaminstmnararm.prapeny,IIItheIntamulbanpravldpt!aaccu".M INlluntxate ImY use peMA"Mat�cial durpeyrrt�,lraeoa4tasMaa a*wil MnblatnM prtortomwtarrwmam etwd rosr>am�ios uiderchaplar 313,FiorYte SUtuNs to mt<Wain orprapetly.atNndert p'�wek;w,tuAYv�}?MtI Om wiutucwt,.1 hNbstraNy tlutAs(dlannellen wu w pleb appteeskn is acarats sadthal l wit obtain 0*41 sM ter111&&e.Rel dttte)etmaioii provibed Is seume.20 1Wfilm ftv"541: rae.31 sly wrovalimmayar.t ra45114s.orual powiom nh.uapptsaw.toome.topiumeawee re5ponsBapdfas usutea sopva.Cam,eorcJNs tndhi.itpAasaartefbdJ.lriLp or Mttit9m&Ibor yaeeaes waviatkike ol[taer DnYka'WNIa>0tl.ys esa cpmplati.nal'WawmWn6n.mppY mannadon.0 w me wessu duft the owstraadton npdr.rrndpta4t7oti Aw. Ah6 ppriit. sbaedtnmanl suwulud by tli}aSM,rroL or the ParS ski--all--n,."Oct accum frrl, 'Signature of Contras hi -License No. -Signature of Owner or(:Agen 'Date I BELOW -FOR OFFICIAL Apprrrvai Giant ed 8y Issue Date Z(t7 ( Expiratlon Date 5�s l Hydrologlsl Apfoval uw4h Fee Received S Receipt No. Check No. 1 t THIS PERMIT IS NOTVALID UNTIL PROPERLY SIGNED BY AN AUTHORIZED OFFICER OR REPRESENTATIVE OF THE MD OR DELEGATED AUTHORITY,THE PERMIT SHALL BE.AVAILABLE AT THE WELL SITE DURING ALL CONSTRUCTION,REPAIR,MODIFICATION,OR ABANDONMENT ACTIVITIES. l ) I I i FORM R405-2014 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: HAYS RESIDENCE Builder Name: COLE CONSTRUCTION SERVICES LLC Street: 1720 S BROCKSMITH RD. Permit Office: ST.LUCIE COUNTY -tity,State,Zip: FT.PIERCE,FL, Permit Number:1702-0071 Owner: JODY&PETER HAYS Jurisdiction: Design Location: FL,Fort Pierce County:: ST.LUCIE COUNTY(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types(2085.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Ext Insul, Exterior R=4.2 1985.00 ft2 b.Frame-Wood,Exterior R=11.0 100.00 ft2 3. Number of units,if multiple family 1 c.N/A R= ftz 4. Number of Bedrooms 3 d.N/A R= ft2 5. Is this a worst case? No 10.Ceiling Types (2136.0 sqft.) Insulation Area a.Under Attic(Vented) R=30.0 2136.00 ft2 6. Conditioned floor area above grade(ft2) 2136 b.N/A R= ft2 Conditioned floor area below grade(ft2) 0 c.N/A R= ft2 11.Ducts R ft2 7. Windows(222.9 sqft.) Description Area a.Sup:Attic,Ret:Attic,AH:Garage 6 425 a. U-Factor: Dbl,U=0.65 222.91 ft2 SHGC: SHGC=0.25 b. U-Factor: N/A ft2 12.Cooling systems kBtu/hr Efficiency SHGC: a.Central Unit 41.0 SEER:16.00 c. U-Factor: N/A ft2 SHGC: 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a.Electric Strip Heat 34.0 COP:1.00 SHGC: Area Weighted Average Overhang Depth: 8.961 ft. Area Weighted Average SHGC: 0.250 14. Hot water systems 8. Floor Types (2136.0 sqft.) Insulation Area a.Electric Cap:40 gallons - a.Slab-On-Grade Edge Insulation R=0.0 2136.00 ft2 b. Conservation features EF:0.970 b.N/A R= ft2 None c.N/A R= ft2 15.Credits Pstat Glass/Floor Area:. 0.104 Total Proposed Modified Loads: 72.25 PASS Total Baseline Loads: 72.94 1 hereby certify that the plans and specifications covered by Review of the plans and T$E ST9?' this calculation are in compliance with the Florida Ener y specifications covered by this Code. calculation indicates compliance with the Florida Energy Code. PREPARED BY: Before construction is completed DATE: -lam this building will be inspected for compliance with Section 553.908 I hereby certify that this building, as designed, is in compliance Florida Statutes. with the Florida Energy C de. COD WE T4� OWNER/AGENT:-AV-4BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.2.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage test report in accordance with R402.4.1.2. I e E Copy , 5/1/2017 2:18 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 6 i FORM R405-2014 PROJECT Title: HAYS RESIDENCE Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 2136 Lot# Owner: JODY&PETER HAYS Total Stories: 1 Block/SubDivision: #of Units: 1 Worst Case: No PlatBook: Builder Name: COLE CONSTRUCTION SER Rotate Angle: 0 Street: 1720 S BROCKSMITH Permit Office: ST.LUCIE COUNTY Cross Ventilation: No County: ST.LUCIE COUNTY •Jurisdiction: Whole House Fan: No City,State,Zip: FT. PIERCE, Family Type: Single-family FL, New/Existing: New(From Plans) 'Comment: CLIMATE / IECC Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site Zone 97.5% 2.5% Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VERO_BEACH_MUNI 2 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 2136 21810 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 MUD ROOM 101 1010 No 0 1 Yes Yes Yes 2 LAUNDRY 42 420 No 0 1 Yes Yes Yes 3 PANTRY 63 630 No 0 1 Yes Yes Yes • 4 WIC 2 66 660 No 0 1 Yes Yes Yes 5 MASTER BEATH 176 1760 No 0 1 Yes Yes Yes 6 MASTER BEDROO 231 2310 No 1 1 1 Yes Yes Yes 7 WIC 77 770 No 0 1 No Yes Yes 8 KITCHEN 270 2700 Yes 0 1 Yes Yes Yes 9 GREAT ROOM 450 4950 No 2 1 Yes Yes Yes 10 BEDROOM 3 168 1680 No 1 1 1 Yes Yes Yes 11 BATH#3 48 480 No 0 1 Yes Yes Yes 12 BATH 3 48 480 No 0 1 Yes Yes Yes 13 BEDROOM 2 180 1800 No 1 1 1 Yes Yes Yes 14 POWDER 21 210 No 0 1 No Yes Yes 15 FOYER 132 1320 No 0 1 Yes Yes Yes 16 HALL 63 630 No 0 1 No Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab-On-Grade Edge Insulatio MUD ROOM 21 ft 0 101 ftZ ---- 0 1 0 2 Slab-On-Grade Edge Insulatio LAUNDRY 7 ft 0 42 ftZ ---- 0 1 0 5/1/2017 2:18 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 6 FORM R405-2014 FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 3 Slab-On-Grade Edge Insulatio PANTRY 4 ft 0 63 ft2 ---- 0 1 0 4 Slab-On-Grade Edge Insulatio WIC 2 6 ft 0 66 ft2 ---- 0 1 0 w 5 Slab-On-Grade Edge Insulatio MASTER BEATH 27 ft 0 176 ft2 ---- 0 1 0 6 Slab-On-Grade Edge Insulatio MASTER BEDRO 14 ft 0 231 ft2 ---- 0 1 0 7Slab-On-Grade Edge Insulatio WIC 1 ft 0 77 ft2 ---- 0 1 0 8 Slab-On-Grade Edge Insulatio KITCHEN 18 ft 0 270 ft2 ---- 0 1 0 9 Slab-On-Grade Edge Insulatio GREAT ROOM 45 ft 0 450 ft2 ---- 0 1 0 10SIab-On-Grade Edge Insulatio BEDROOM 3 14 ft 0 168 ft2 ---- 0 1 0 11SIab-On-Grade Edge Insulatio BATH#3 14 ft 0 48 ft2 ---- 0 1 0 12SIab-On-Grade Edge Insulatio BATH 3 6 ft 0 48 ft2 ---- 0 1 0 13SIab-On-Grade Edge Insulatio BEDROOM 2 12 ft 0 180 ft2 ---- 0 1 0 14SIab-On-Grade Edge Insulatio POWDER 1 ft 0 21 ft2 ---- 0 1 0 15SIab-On-Grade Edge Insulatio FOYER 6ft 0 132 ft2 ---- 0 1 0 16SIab-On-Grade Edge Insulatio HALL 1 ft 0 63 ft2 ---- 0 1 0 ROOF / Roof Gable Roof Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Hip Composition shingles 2251 ft2 0 ft2 Light 0.6 No 0.9 No 0 18.4 ATTIC V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC 1 Full attic Vented 150 2136 ft2 N N i 5/1/2017 2:18 PM EnergyGauge@ USA-FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 6 FORM R405-2014 CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic(Vented) MUD ROOM 30 Blown 101 ft2 0.1 Wood 2 Under Attic(Vented) LAUNDRY 30 Blown 42 ft2 0.1 Wood 3 Under Attic(Vented) PANTRY 30 Blown 63 ft2 0.1 Wood 4 Under Attic(Vented) WIC 2 30 Blown 66 ft2 0.1 Wood 5 Under Attic(Vented) MASTER BEATH 30 Blown 176 ft2 0.1 Wood 6 Under Attic(Vented) MASTER BEDRO 30 Blown 231 ft2. 0.1 Wood 7 Under Attic(Vented) WIC 30 Blown 77 ft2 0.1 Wood 8 Under Attic(Vented) KITCHEN 30 Blown 270 ft2 0.1 Wood 9 Under Attic(Vented) GREAT ROOM 30 Blown 450 ft2 0.1 Wood 10 Under Attic(Vented) BEDROOM 3 30 Blown 168 ft2 0.1 Wood 11 Under Attic(Vented) BATH#3 30 Blown 48 ft2 0.1 Wood 12 Under Attic(Vented) BATH 3 30 Blown 48 ft2 0.1 Wood 13 Under Attic(Vented) BEDROOM 2 30 Blown 180 ft2 0.1 Wood 14 Under Attic(Vented) POWDER 30 Blown 21 ft2 0.1 Wood 15 Under Attic(Vented) FOYER 30 Blown 132 ft2 0.1 Wood 16 Under Attic(Vented) HALL 30 Blown 63 ft2 0.1 Wood WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below Space lleren ,leEractsnr1 E Exterior Concrete Block-Ext InsMUD ROOM 4.2 10 0 10 0 100.0 ft2 0 0 0.6 0 2 S Exterior Concrete Block-Ext InsMUD ROOM 4.2 1 0 '10 0 10.0 ft2 0 0 0.6 0 3 W Exterior Concrete Block-Ext InsMUD ROOM 4.2 10 0 10 0 100.0 ft2 0 0 0.6 0 4 W Exterior Concrete Block-Ext Insi11AUNDRY 4.2 7 0 10 0 70.0 ft2 0 0 0.6 0 5 S Exterior Concrete Block-Ext InsuPANTRY 4.2 4 0 10 0 40.0 ft2 0 0 0.6 0 6 S Exterior Concrete Block-Ext Insul WIC 2 4.2 6 0 10 0 60.0 ft2 0 0 0.6 0 7 E Exterior Concrete Block-Ext Indd14STER BE 4.2 11 0 10 0 110.0 ft2 0 0 0.6 0 8 S Exterior Concrete Block-Ext Ins1AWSTER BE 4.2 16 0 10 0 160.0 ft2 0 0 0.6 0 9 E Exterior Concrete Block-Ext InsMASTER BE 4.2 14 0 10 0 140.0 ft2 0 0 0.6 0 10 W Exterior Concrete Block-Ext InsuKITCHEN 4.2 18 0 10 0 180.0 ft2 0 0 0.6 0 _11 N Exterior Concrete Block-Ext Ina%REAT ROO 4.2 15 0 11 0 165.0 ft2 0 0 0.6 0 _12 W Exterior Concrete Block-Ext InGREAT ROO 4.2 30 0 11 0 330.0 ft2 0 0 0.6 0 13 N Exterior Concrete Block-Ext InfiffDROOM 3 4.2 14 0 10 0 140.0 ft2 0 0 0.6 0 14 N Exterior Concrete Block-Ext InsuBATH#3 4.2 8 0 10 0 80.0 ft2 0 0 0.6 0 15 E Exterior Concrete Block-Ext InsuBATH#3 4.2 6 0 10 0 60.0 ft2 0 0 0.6 0 16 E Exterior Concrete Block-Ext Insul BATH 3 4.2 6 0 10 0 60.0 ft2 0 0 0.6 0 17 E Exterior Concrete Block-Ext In!flffDROOM 2 4.2 12 0 10 0 120.0 ft2 0 0 0.6 0 18 E Exterior Concrete Block-Ext Insul FOYER 4.2 6 0 10 0 60.0 ft2 0 0 0.6 0 19 N Exterior Frame-Wood MUD ROOM 11 10 10 100.0 ft2 0.23 0.6 0 I I 5/1/2017 2:18 PM EnergyGaugeO USA-FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 6 FORM R405-2014 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 W Insulated MUD ROOM None .39 2 10 8 22.7 ftZ 2 E Insulated FOYER None .39 3 8 24 ftz WINDOWS Orientation shown is the entered,Proposed orientation. / Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening 1 E 1 Metal Low-E Double Yes 0.65 0.25 12.0 ftZ 12 ft 0 in 1 ft 4 in None None 2 E 7 Metal Low-E Double Yes 0.65 0.25 9.0 ftz 2 ft 0 in 1 ft 4 in None None 3 E 9 Metal Low-E Double Yes 0.65 0.25 28.3 ftZ 6 ft 0 in 1 ft 4 in None None 4 W 10 Metal Low-E Double Yes 0.65 0.25 24.0 ftZ 12 ft 0 in 1 ft 4 in None None 5 W 12 Metal Low-E Double Yes 0.65 0.25 96.0 ft2 12 ft 0 in 1 ft 4 in None None 6 N 13 Metal Low-E Double Yes 0.65 0.25 15.0 ftZ 2 ft 0 in 1 ft 4 in None None 7 E 15 Metal Low-E Double Yes 0.65 0.25 9.0 ftz 2 ft 0 in 1 ft 4 in None None 8 E 17 Metal Low-E Double Yes 0.65 0.25 14.6 ftZ 6 ft 0 in 1 ft 4 in None None 9 E 17 Metal Low-E Double Yes 0.65 0.25 15.0 ftZ 6 ft 0 in 1 ft 4 in None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation 1 140ft2 140ft2 loft loft 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000454 2544.5 139.69 262.71 .3315 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Strip Heat None COPA 34 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit Split SEER: 16 41 kBtu/hr cfm 0.8 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.97 40 gal 60.9 gal 120 deg None 5/1/2017 2:18 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 5 of 6 FORM R405-2014 SOLAR HOT WATER SYSTEM FSEC Collector Storage Cart # Company Name System Model# Collector Model# Area Volume FEF None None ftZ DUCTS / ---Supply --Return— Air CFM 25 CFM25 HVAC# V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 425 ftZ Attic 105 ftz Default Leakage Garage (Default) (Default) 1 1 TEMPERATURES Programable Thermostat:Y Ceiling Fans: Coolingan Feb Mar Apr jMa rj Jun rl Jul ri Au rl Se Oct Nov ]Dec Heatin Jan HFeb Mar E APr I May Jun Jul AuSep Oct XNovDecVentin Jan Feb X Mar [x]A r May Jun Jul Aug Se [X]Oct X Nov [ ]]Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 5/1/2017 2:18 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 6 of 6 I ' FORM R405-2014 TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: HAYS RESIDENCE Builder Name: COLE CONSTRUCTION SERVICES LLC Street: 1720 S BROCKSMITH RD. Permit Office: ST. LUCIE COUNTY City,State,Zip: FT.PIERCE, FL, Permit Number:1702-0071 Owner: JODY&PETER HAYS Jurisdiction: Design Location: FL,Fort Pierce COMPONENT CRITERIA CHECK Air barrier and thermal barrier A continuous air barrier shall be installed in the building envelope. Exterior thermal envelope contains a continuous barrier. Breaks or joints in the air barrier shall be sealed. Air-permeable insulation shall not be used as a sealing material. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the insulation and any gaps in the air barrier shall be sealed. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Corners and headers shall be insulated and the junction of the foundation Walls and sill plate shall be sealed. The junction of the top plate and the top or exterior walls shall be sealed. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Knee walls shall be sealed. Windows, skylights and doors The space between window/door jambs and framing and skylights and framing shall be sealed. Rim joists Rim joists are insulated and include an air barrier. Floors (including above-garage Insulation shall be installed to maintain permanent contact with underside and cantilevered floors) of subfloor decking. The air barrier shall be installed at any exposed edge of insulation. Crawl space walls Where provided in lieu of floor insulation, insulation shall be permanently attached to the crawlspace walls. Exposed earth in unvented crawl spaces shall be covered with a Class I vapor retarder with overlapping joints taped. Shafts, penetrations Duct shafts, utility penetrations, and flue shaft openings to exterior or unconditioned space shall be sealed. Narrow cavities Batts in narrow cavities shall be cut to fit, or narrow cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal envelope shall be air tight, IC rated,and sealed to the drywall. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind piping and wiring. Shower/tub on exterior wall Exterior walls adjacent to showers and tubs shall be insulated and the air barrier installed separating them from the showers and tubs. Electrical/phone box on The air barrier shall be installed behind electrical or communication boxes or air sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub-floor or drywall. Fireplace An air barrier shall be installed on fireplace walls. Fireplaces shall have gasketed doors 5/1/2017 2:19 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 1 FORM R405-2014 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 99 The lower the EnergyPerformance Index, the more efficient the home. 1720 S BROCKSMITH RD., FT. PIERCE, FL, 1. New construction or existing New(From Plans) 9. Wall Types Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Ext Insul, Exterior R=4.2 1985.00 ftz b.Frame-Wood, Exterior R=11.0 100.00 ftz 3. Number of units,if multiple family 1 c.N/A R= ftz 4. Number of Bedrooms 3 d.N/A R= ftz 5. Is this a worst case? No 10.Ceiling Types Insulation Area a.Under Attic(Vented) R=30.0 2136.00 ftz 6. Conditioned floor area(ftz) 2136 b.N/A R= ftz _ z 7. Windows— Description Area 11 Ducts R R ftz a. U-Factor: Dbl,U=0.65 222.91 ftz SHGC: SHGC=0.25, a.Sup:Attic,Ret:Attic,AH:Garage 6 425 b. U-Factor: N/A ftz SHGC: 12.Cooling systems kBtu/hr Efficiency c. U-Factor: N/A ftz a.Central Unit 41.0 SEER:16.00 SHGC: d. U-Factor: N/A ftz 13.Heating systems kBtu/hr Efficiency SHGC: a.Electric Strip Heat 34.0 COP:1.00 Area Weighted Average Overhang Depth: 8.961 ft. Area Weighted Average SHGC: 0.250 8. Floor Types Insulation Area 14.Hot water systems a.Electric Cap:40 gallons a.Slab-On-Grade Edge Insulation R=0.0 2136.00 ftz EF:0.97 ^ b.N/A R= ftz C.N/A R= ftz b. Conservation features None 15.Credits Pstat I certify that this home has complied with the Florida Energy Efficiency Code for Building 4'�KEST�T Construction through the above energy saving features which will be installed (or exceeded) IV in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. 0 Builder Signature: Date: �I Address of New Home: City/FL Zip: *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage(EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at(321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 5/1/2017 2:18 PM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Compliant Software Page 1 of 1 - htsoftm 9 Protect Summary Job: wri �! '7 Date: Jan 30,2017 Enure House By: QUICK CALCS, INC. 317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone:772-466-6799 Fax 772-466-6796 Email:QUICKCALCS@AOL.COM Proaect Information For: HAYS RESIDENCE ST. LUCIE COUNTY, FL Notes: Desicin Information Weather: Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db 70 OF Inside db 75 OF Design TD 28 OF Design TD 15 OF Daily range L Relative humidity 50 % Moisture difference 61 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 24971 Btuh Structure 19324 Btuh Ducts 7008 Btuh Ducts 11402 Btuh Central vent (69 cfm) 2125 Btuh Central vent (69 cfm) 1139 Btuh Outside air Outside air Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 34104 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Infiltration Equipment sensible load 30271 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 3430 Btuh Ducts 3133 Btuh Central vent(69 cfm) 2885 Btuh Heatingg Cooling Outside air Area(ft2 2136 2136 Equipment latent load 9448 Btuh Volume(ft3) 21810 21810 Air changes/hour 0.32 0.16 Equipment total load 39720 Btuh Equiv.AVF (cfm) 116 58 Req. total capacity at 0.70 SHR 3.6 ton Heating Equipment Summary Cooling Equipment Summary Make Make Trane Trade Trade TRAN E Model Cond 4TTR40431-1 AHRI ref Coil TEM6AOD48H41++TDR AHRI ref 7567550 Efficiency 100 EFF Efficiency 13.0 EER, 16 SEER Heating Input 5.1 kW Sensible cooling 28700 Btuh Heating output 17448 Btuh Latent cooling 12300 Btuh Temperature rise 50 OF Total cooling 41000 Btuh Actual air flow 318 cfm Actual airflow 1367 cfm Air flow factor 0.010 cfm/Btuh Air flow factor 0.044 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio FILE COPY Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. C Wrl IItSOft' 2017-Jan-3011:09:23 9 Right-Suite®Universal 2017 17.0.14 RSU08101 Page 1 6CA ...Quick Calcs\Documents\HAYS-ST.LUCIE COUNTY.rup Calc=MJ8 Front Door faces: N -wrightsoft'. Right-JO Worksheet Job: Entire House Date: Jan 30,2017 QUICK CALCS, INC. By: 317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone:772-466-6799 Fax 772-466-6796 Email:QUICKCALCS@4OL.COM 1 Room name Entire House MUD ROOM 2 Exposed wall 194.0 ft 21.0 ft 3 Room height 10.2 ft d 10.0 ft heat/cool 4 Room dimensions 1.0 x 101.0 ft 5 Room area 2136.0 ft2 101.0 ft2 Ty Construction U,-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ft2-°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) ' Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 IV- 13A-4ocs 0.143 ne 4.00 2.55 650 538 2154 1370 100 w- 352 r f24 4A5-2om 0.770 ne 21.56 36.90 18 0 388 664 0 0 0 . 0 4A5-2om 0.770 ne 21.56 36.90 12 0 259 443 12 0 -259 443 4A5-2om 0.770 ne 21.56 36.90 28 0 611 1045 0 0 0 0 11 4A5-2om 0.770 ne 21.56 36.90 15 0 314 538 0 0 0 0 4A5-2om 0.770 ne 21.56 36.90 15 0 323 553 0 0 0 0 =-D ___ _ 0.390 ne 10.92 _ 11..31 ___-_24 24 262 271 -0 -__ 0_ .0 W 13A�ocs _ _ 0.143-se _ _ 4.00 _ 2.55 270 _ 270 _ 1081 _ 687 10 10 40 25 h W 13A-4ocs 0.143 sw 4.00 2.55 680 537 2151 1366 100 77 316 19710D-m 1.390 sw 38.92 20.03 96 96 3736 1922 0 0 0 0 4A5-tom 0.770 sw 21.56 19.31 24 24 517 463 0 0 0 0 - 11D0 0.390 sw.- 10.92 _ 11.31 __ _ 23_ 23 248 - _ 256 _ --2 3-_ _-. 23 _ 248 _.. 256 Lw 13A-4ocs 0.143 nw 4.00 2.55 385 370 1481 942 0 0 0 0 -G 4A5-2om _ _0.770 nw _ -21.56 36.90 15 _ 0__ 323 _ 553 _0 0 _ _ ___0 .-_. 0 0--- _12C=0sw---_ _ _•_0.091.- _ .2.55_ 1.28 100__ 100_ __. '255 128_ 100 100_ __ 255-_ _--. 128. C-...-_ 16B-30md.,_ _-0,032 - _0.90 1.68- 2136 2136 1914 3588 „ . 101 101_ 90 a_.170, 22A-tpl. __.. _ _ ._ _0.989_ __ _ 27.69 _ _0.00- _2136 194 - 582-- - _5372 _0 _101 21 0_ 6 c)AED excursion 1421 -32 Envelope loss/gain 21392 16215 2135 1412 12 a) Infiltration 3579 959 379 101 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 5 1150 0 0 Appliances/other 1000 0 Subtotal(lines 6 to 13) 24971 19324 2514 1513 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 24971 19324 2514 1513 15 Duct loads 28% 59% 7008 11402 28% 59% 705 893 Total room load 31979 30726 3219 2406 Air required(cfm) 318 1367 32 107 Calculations approved by ACCA to meet all Calculations approved by to meet all requirements of Manual J 8th Ed. Manual J 8th Ed wrightsoft' Right-Suite®Universal 2017 17.0.14 RSU08101 2017-Jan-30 1:009:23 ...Quick Calcs\Documents\HAYS-ST.LUCIE COUNTY.rup Calc=MJ8 Front Door faces: N g - -wrightscift° Right-A)Worksheet Job: Entire House Date: Jan 30,2017 QUICK CALCS, INC. BY: 317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone:772-466-6799 Fax 772-466-6796 Email:QUICKCALCS@AOL.COM 1 Room name LAUNDRY PANTRY 2 Exposed wall 3 Room height 10.0 ft 7 0 ft heat/cool 10.0 ft 4.0 ft heat/cool 4 Room dimensions 7.0 x 6.0 ft 7.0 x 9.0 ft 5 Room area 42.0 ft2 63.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ft2-°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6--- 13A-4ocs - - - 0.143 ne 4.00 2.65 -- - - 0 --- -0 -6 - - -0 -0 0 --- 0 4A5.2om 0.770 ne 21.56 36.90 0 0 0 0 0 0 0 0 4A5-2om 0.770 ne 21.56 36.90 0 0 0 0 0 0 0 0 4A5.2om 0.770 ne 21.56 36.90 0 0 0 0 0 0 0 0 11 4A5-2om 0.770 ne 21.56 36.90 0 0 0 0 0 0 0 0 4A5-2om 0.770 ne 21.56 36.90 0 0 0 0 0 0 0 0 11DO 0.390 ne 10.92 11.31- -_ . 0 0 0 0 0 _0 , 0 _ 0 W 13,A-4ocs _ _ _ 0.143-se __4.00 2.55 0 _ 0 . 0 0 40 40 160 102 V1l 13A4ocs 0.143 sw 4.00 2.55 70 70 280 178- 0 0 0 - --0 1OD-m 1.390 sw 38.92 20.03 0 0 0 0 0 0 0 0 4A5-2om 0.770 sw 21.56 19.31 0 0 0 0 0 0 0 0 11 D0_ 0.390 sw ___10.92, 11.31 - _. -0 __ _ .0_- 0,_ W 13A-4ocs 0.143 rnv 4.00 2.55 0 0 0 0 0 0 0 0 L--G 4A5-2om-___ _, .-- _ _ 0.770 nw 21.56 36_90 _ - 0 - 0__ 0. 0 _ ._ 0 0_ 0 P -- -12C-Osw_. --- _ - .....0.991 - 2.5.5 _ .-1.28 0 0 - 0 - 0-- 0 ---0 -- 0- 0-. .. _ 0 C.-__ 16B-30md__ 0.032 - 0.90_ 1..68 42 42 _ 38 71 63 63 56 . _ 106 22A-tpl ____. _0.989 - 27.69. 0.00 _42 7 ... -_.194 _ 0 63 0.. - -- - ---------------- -- --- -- -- 6 c)AED excursion -6 -5 Envelope loss/gain 512 243 327 203 12 a) Infiltration 126 34 72 19 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 638 277 400 222 Less external load I 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 638 277 400 222 151 Duct loads 28% 59% 179 163 28% 59% 112 131 Total room load 817 440 512 353 Air required(cfm) 8 20 5 16 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. _:I-� -Fk" wriglhtsaft- I 2017-Jan-30 11:09:23 Right-Suite®Universal 2017 17.0.14 RSU08101 Page 2 ...Quick Calcs\Documents\HAYS-ST.LUCIE COUNTYrup Calc=MJ8 Front Door faces: N - wrightsoft° Right-J®Worksheet Job: Entire House Date: Jan 30,2017 QUICK CALCS, INC. 317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone:772-466-6799 Fax 772-466-6796 Email:QUICKCALCS@AOL.COM 1 Room name WIC 2 MASTER BEATH 2 Exposed wall j 3 Room height 10.0 ft 6.0 ft heat/cool 10.0 ft 27 O ft heat/cool 4 Room dimensions 11.0 x 6.0 ft 11.0 x 16.0 ft 5 Room area 66.0 ft2 176.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ft2-°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) ' Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 -- 13A-4ocs. -- - 0.143 ne -4.00 2.55 - -0- - -_6- - - -0 - 0 - ---110 ----101 - 404 4A5-tom, 0.770 ne 21.56 36.90 0 0 0 0 9 0 194 332 4A5-2om 0.770 ne 21.56 36.90 0 0 0 0 0 0 0- 0 4A5-2om. 0.770 ne 21.56 36.90 0 0 0 0 0 0 0 0 11 4A5-2om 0.770 ne 21.56 36.90 0 0 0 0 0 0 0 0 4A5-2om 0.770 ne 21.56 36.90 0 0 0 0 0 0 0 0 11DO -_, _ _._ 0.390 -ne 10.92 11.31 0 _ _ 0 _ _ ___0 __. 0 0 0_ 0 0 W__- 13A�locs___ __ _ -, 0.143 _se_ ___4,- _ _255 60 ___ _60 _ ___240 153_ _1_60 _160 641 - _ 407 W 13A-flocs 0.143 sw 4.00 2.55 0 0 0 0 0 0 - 0 0 10D-m 1.390 sw 38.92 20.03 0 0 0 0 0 0 0 0 4A5.2om 0.770 sw 21.56 19.31 0 0 0 0 0 0 0 0 - 11D0__ _- ._ . _ _ _.-0.390_sw __-10.92 __11.31_ __ 0._-_ -- _0 WII -- 13A-4ocs 0.143 nw 4.00 2.55 0 6 0 0 0 0 0 0 P.L-G 4A5-2om__ 0.770_nw 21.56 36.90 0 0 0 0 0 _ 0 0 _-_-0 _---- - 2.55 - 0 --0 - -0 ----0 - -0-- 0. - 0 - 0 _16B_30md _ _ 032_ - _ 0.90- 1:68 66 -_ 66 59 111 176 176 158 296 F --- 22A-tpl, - --_0.989 - - _ 27.69 . 0.00 _ 66 6 _ _-_166 _0 ._ -_.176 _._ _27..__ _ 748- .------0 6 c)AED excursion -6 -29 Envelope loss/gain 466 258 2144 1263 12 a) Infiltration 108 29 487 130 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 574 287 2631 1393 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 574 287 2631 1393 15 Duct loads 28% 59% 161 169 28% 59% 738 822 Total room load T7735 456 3370 2215 Air required(cfm) 7 20 33 99 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed s-7- -Fk wrightsoft- Right-Suite®Universal 2017 17.0.14 RSU08101 2017-Jan-30 1 Page 3 ...Quick Calcs\Documents\HAYS-ST.LUCIE COUNTY.rup Calc=MJ8 Front Door faces: N . i - wrightsoft° Right-J®Worksheet Job: Entire House Date: Jan 30,2017 QUICK CALCS, INC. 317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone:772-466-6799 Fax:772-466-6796 Email:QUICKCALCS@AOL.COM 1 Room name MASTER BEDROOM WIC 2 Exposed wall 3 Room height 10.0 ft 14.0 ft heat/cool 10.0 ft Oft heat/cool 4 Room dimensions 1.0 x 231.0 ft 11.0 x 7.0 ft Dorn area 231.0 ft2 77.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ft2-°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) ' Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13A flocs - 0.143 n-e -. .4.0-0 _ -2.55 140 112 447 - - --28_4- -0 - -6- - -0.. 0 4A5-2om -0.770 ne 21.56 36.90 -0 0 0 0 0 0 0 0 4A5.2om 0.770 ne 21.56 36.90 0 0 0 0 0 0 0 0 4A5-2om 0.770 ne 21.56 36.90 -28 0 611 1045 0 0 0 0 11 4A5-2om,.• 0.770 ne 21.56 36.90 0 0 0 0 0 0 0 0 4A5-2om 0.770 ne 21:56 36.90 0 0 0 0 0 0 0 0 _-_- - 11 DO_ _------- - --- ---0 390 ne _ 10.92 --_11 31.-.- --__0 --- 0- - 0 - W _ _ 13A-0ocs _ _ 0.143 se_ _ 4.00- _ 2.55 _ 0 0 _ __0._ 0. 0 _ _ _-_ 0 _ 0 _ _ -_ _0 W 13A-4ocs 0.143 sw 4:00 2.55 0 0 .0 .0 0 .0 0 0 10D-m 1.390 sw 38.92 20.03 0 0 0 0 0 0 0 0 4A5-2om 0.770 sw 21.56 19.31 0 0 0 0 0 0 0 0 _ 11-DO - _ _ __0.390 -sw ,_ 10.92, 11.31 , 0 -0 0 _ 0 _ 0 _ -0 _ 0 0 W 13A-4ocs 0.143 nw 4.00 2.55 0 0 0 0 0 0 0 0 _� 465-2om„ ._ _ -0.770_nw_ _ 21.56 36.90 0 P_- 12C-Osw _- . __ __ _6-_* - _ _ 2.55.__ 1.28 _0. _0 C _ _ 16B-30md_ 0.032 0.90__. _1.68 _ 231 _ 231 207. 388 77 77___ _69 _ 129 F- .22A-tpl__.. - - 0.989 _- _ _27.69`-_ O.W. -_231 14 _388_ 0 77 0 0 - ` _0 6 c)AED excursion -41 -3 Envelope loss/gain 1653 1676 69 127 12 a) Infiltration 252 68 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 1 230 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 1905 1974 69 127 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 1905 1974 69 127 15 Duct loads 28% 59% 535 1165 28% 59% 19 75 Total room load 2440 3139 88 201 Air required(cfm) 24 1401 1 9 I Calculations approved by ACCA to meet all requirements of Manual J 8th Ed wrightsoft' Right-Suite®Universal 2017 17.0.14 RSU08101 2017-Jan-30 1 Page 4 ...Quick Calcs\Documents\HAYS-ST.LUCIE COUNTY.rup Calc=MJ8 Front Door faces: N 9 I i -�-wrightsoft° Right-M Worksheet Job: Entire House Date: Jan 30,2017 QUICK CALCS, INC. 317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone:772-466-6799 Fax 772-466-6796 Email:QUICKCALCS@4OL.COM 1 Room name KITCHEN GREAT ROOM 2 Exposed wall 18.0 ft 45.0 ft 3 Room height 10.0 ft heat/cool 11.0 ft heat/cool 4 Room dimensions 18.0 x 15.0 ft 30.0 x 15.0 ft ' 5 Room area 270.0 ft2 450.0 ft2 Ty Construction U-value Or HTM Area (ft� Load Area (ft2) Load number (Btuh/ft2�°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13A-4ocs 0.143 ne 4.00 2.55 0 ' 0 0 6 0 6 6 6 4A5-2om 0.770 ne 21.56 36.90 0 0 0 0 0 0 0 0 4A5-2om 0.770 ne 21:56 36.90 0 0 0 0 0 0 0 0 4A5-2om 0.770 ne 21.56 36.90 0 0 0 0 0 0 0 0 11 4A5-2om 0.770 ne 21.56 36.90 0 0 0 0 0 0 0 0 4A5-2om.. 0.770 ne 21.56 36.90 0 0 0 0 0 0 0 0 11 D0__ -- ---.- -- -0.390 ne _--10.92 11.31 _ _ __ 0 - _0_ 0 -- -0 _ - -0 __--.- _0_ -__-- 0 - _ -0 W - 13A-40cs 0143_se - 4.00 255 0-_ 0 0 0 0 _..0 0 0 13A�ocs 0.143 sw 4.00 2.55 160 156 .625 397_ 330 2M 937 596 10D-m 1.390 sw 38.92 20.03 0 0 0 0 96 96 3736 1922 4A5-2om 0.770 sw 21.56 19.31 24 24 517 463 0 0 0 0 11 D0 --0.390 sw -_-10.92 -11.31 -.,,,- 0 -0 0 0 - - 0 0 0 _0 W 13A-4ocs 0.143 nw 4.00 2.55 0 0 0 0 165 165 661 420 W--G 4A5-2om__-_ 0.770 rnv- 21.56_ 36.90 0 _ _ 0_ 0 _ 0_ _ 0 0 0 0 P - 12C-0sw - -- ---0.091 - --2.55 1.28 - ---0 -- - _Q -- - -� -- 6 --- -�- - 0 0. C-.._ _ 16B-30md 0._032_- 0.90 _-_.1.68 270._ _. 270 _ _„- _242_.___ 454, 450 _ _ 456 403 . 756 F -- 22A-tpl _ 0.989 _-_ _27.69 0.00 270 _ 18 498 0. 450 45 _ 1246 _ 0- - --- - --- --- -- - 6 c)AED excursion 335 1121 Envelope loss/gain 1882 1649 6983 4815 12 a) Infiltration 325 87 893 239 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 2 460 Appliances/other 1000 0 Subtotal(lines 6 to 13) 2207 2736 7876 5514 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 2207 2736 7876 5514 15 Duct loads 28% 59% 619 1614 28% 59% 2210 3253 Total room load 2826 4351 10086 8767 Air required(cfm) 28 1941 1 1100 390 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. � ' wrightsoft' Right-Suite® Pa Universal 2017 17.0.14 RSUD8101 2017-Jan-30 11:age 5 ...Quick Calcs\Documents\HAYS-ST.LUCIE COUNTY.rup Calc=MJ8 Front Door faces: N I • i - -wrightsoft° Right-M Worksheet Job: Entire House Date: Jan 30,2017 QUICK CALCS, INC. By. 317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone:772-466-6799 Fax 772-466-6796 Email:QUICKCALCS@,AOL.COM 1 Room name BEDROOM 3 BATH#3 2 Exposed wall 14.0 ft 14.0 ft 3 Room height 10.0 ft heat/cool 10.0 ft heat/cool 4 Room dimensions 12.0 x 14.0 ft 6.0 x 8.0 ft ' 5 Room area 168.0 ft2 48.0 ftz Ty Construction U-value Or HTM Area (ft� Load Area (W) Load number (Btuh/ft?°F) (Btuh/ft� or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 , _ - -13A-4ocs _ _.. 0.143 ne 4.00 2.55 0 -0 -0 0 i30 51 M4' 130 4A5-2om-- 0.770 ne 21.56 36.90 0 0 0 0 9 0 194 332 4A5-2om 0.770 ne 21.56 36.90 '0 0 0 0 0 0 0 0 4A5-2om' 0.770 ne 21.56 36.90 0 0 0 0 0 0 0 0 11 4A5-2om 0.770 ne 21.56 36.90 0 0 0 0 0 0 0 0 4A5-2om 0770 ne 21.56 36.90 0 0 0 0 0 0 0 0 - _ - 11DO - _- _ __-0.390, ne_ 10.92- _11.31 __ 0 0 0 _ _ 0 _ _ W - 13A-4ocs_. _. _ 0.143 -se 4.00 2.55 0_ _ 0 0 0 6 ___J 0 _ 0_ _ , 0 13A-4ocs. 6A43 sw 4.00 2.55 D 0 0 0 0 0 0 0 10D-m 1.390 sw 38.92 20.03 0 0 0 0 0 0 0 0 4A5-2om 0.770 sw 21.56 19.31 0 0 0 0 0 0 0 0 _ 11D0 --_ -_0.390 -sw. _ 10.92 . .11.31- - __,.0 . . 0_ - 0... w 13A-4ocs 0.143 nw 4.00 2.55 140 125 501 318 80 80 320 204 �--G -4A5 2qm .__ 0.770 nw _ 21.56, -_36_90 15 0 323 553 .__ 0 _ _0 0 _ 0 P --- 12C-0sw_.-. _ .._0._0.91_,_ _ _2.55 .__1.28 - -0 0 C 16B-30md_ _ 0.032__- 0.90 1.68 _ _ 168 168 151 _ 262 _ 46 _ _ F 22A-tpl..._ _0989 _ --27.69_ 0.00 - .._168 -- - -- 81 -- 14 . 388_-. _0 .__. 48 14_. _.388_- -0 6 c)AED excursion 164 -17 Envelope loss/gain 1362 1318 1149 729 12 a) Infiltration 252 68 252 68 b) Room ventilation 0 0 0 0 13 Intemal gains: Occupants @ 230 1 230 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 1615 1615 1402 797 Less extemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 1615 1615 1402 797 15 Duct loads 28% 59% 453 953 28% 59% 393 470 Total room load 2068 2568 1795 1267 Air required(cfm) 21 114 18 56 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrightsoft' Right-Suite®Universal 2017 17.0.14 RSU08101 2017-Jan-30 1 Page 6 ...Quick Calcs\Documents\HAYS-ST.LUCIE COUNTY.rup Cale=MJ8 Front Door faces: N -�-wrightsoft9 Right-M Worksheet Job: Entire House Date: Jan 30,2017 QUICK CALCS, INC. By. 317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone:772-466-6799 Fax 772-466-6796 Email:QUICKCALCS AOL.COM 1 Room name BATH 3 BEDROOM 2 2 Exposed wall 6.0 ft 12.0 ft 3 Room height 10.0 ft heat/cool 10.0 ft heat/cool 4 Room dimensions 6.0 x 8.0 ft 12.0 x 15.0 ft ' 5 Room area 48.0 ft' 180.0 ftz Ty Construction U-value Or HTM Area (ft� Load Area number (Btuhlft2-°F) (Btuh/ft� or perimeter (ft) (Btuh) or (ft� Load perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool ------ -- -- _ _ 6 13A-4ocs a 0143 ne - 4.00 2.55 60 60 240 153 120 90 362 r 230 4A5.2om 0.770 ne 21.56 36.90 0 0 0 0 0 0 0 A 4A5-2om, 0.770 ne 21.56 36.90 0 0 0 0 0 0 0 0 4A5-2om 0.770 ne 21.56 36.90 0 0 0 0 0 0 0 0 11 4A5-2om' 0.770 ne 21.56 36.90 0 0 0 0 15 0 314 538 4A5.2om 0.770 ne 21.56 36.90 0 0 0 0 15 0 323 553 11D0 _ i --- - - -- -----0.390 ne -_- 10.92 .11.31- - -0 - _-- 0 - - 0 ----0------o -- -----0 0_ w 13A-40cs__ 0.143_se __ 4.00 _ z55 0 0 0__ 0 _ 0 0 0 0 w 13A-4ocs 0.143 sw 4.00 2.55 0 0 0 0 0 0 _ 0 0 10D-m 1.390 sw 38.92 20.03 0 0 0 0 0 0 0 0 4A5.2om 0.770 sw 21.56 19.31 0 0 0 0 0 0 0 0 ��----- 11D0_ _. _ .._0.390..sw 10.92_ 11.31 __. _-0 - 0 -- _..__ .0 _ _ -.. 0 0 _0 0 -_-. 0- IwI 13A-40cs 0.143 nw 4.00 2.55 0 0 0 0 0 0 0 0 L--G 4A512om 0,770 nw 21.56 _ 36.90 _ _ 0 _ _ 0 0 0 0 0 0_ 0 Q.091 _- - 2.55 1.28 __ _ 0 _ __ 0 C_-_ 16B_30md _ 0.032 - 0.90 1.68 48 48 43 _ 81 180 _ 180 161 _302 .,0.989- _27.69. __.0.00 _ 48 6 _. , 166 _ - _ 0__. _180-_ 12 _ _--332--_ _ _._0- r, 6 c)AED excursion -5 -39 Envelope loss/gain 449 228 1493 1585 12 a) Infiltration 108 29 216 58 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 1 230 Appliances/other 0 0 Subtotal(lines 6 to 13) 558 257 1710 1873 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 558 257 1710 1873 151 Duct loads 28% 59% 156 152 28% 59% 480 1105 Total room load 714 409 2190 2978 Air required(cfm) 7 18 1 122 132 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. . wrightsoft' Rigtjt-Suite®Universal 2017 17.0.14 RSU08101 2017-Jan-30 11:09:23 14CG'` ...Quick Calcs\Documents\HAYS-ST.LUCIE COUNTY.rup Calc=MJ8 Front Door faces: N Page 7 - -wrightsoft° Right-JO Worksheet Job: Entire House Date: Jan 30,2017 QUICK CALCS, INC. By: 317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone:772-466-6799 Fax.772-466-6796 Email:QUICKCALCS@AOL.COM 1 Room name POWDER FOYER 2 Exposed wall 0 ft 6.0 ft 3 Room height 10.0 ft heat/cool 10.0 ft heat/cool 4 Room dimensions 7.0 x 3.0 ft 6.0 x 22.0 ft } 5 Room area 21.0 ft2 132.0 ft' a Ty Construction U-value Or HTM Area (ft� Load Area (ftz) Load number (Btuhtftz°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 .. 13A�ocs 0.143 ne - 4-:00 2.55 -_0 0 - 0 0 60 36 144 -92 4A5-2om 0.770 ne 21.56 36.90 -0 0 0 0 0 0 0 0 4A5-2om 0.770 ne 21.56 36.90 0 0 0 0 0 0 0 0 4A5-2om 0.770 ne 21.56 36.90 0 0` 0 0 0 0 0 0 11 4A5-2om` 0.770 ne 21.56 36.90 0 0 0 0 0 0 0 0 4A5-2om 0.770 ne 21.56 36.90 0 0 0 0 0 0 0 0 I .11 D0 __ .. _0.390 ne -_ _10.92 _ 11.31 _ _ 0 0- 0 0 .-_- _ 24 _ _- 24 __ _ 262 _____271- W 13A-flocs _ _ 0.143-se 4.00 255 0 0 _ 0 _ _ 0_ 0 _ 0 0 0 W 13A-4ocs 0.143 sw __4.o0 2.55 6 0 0 0 0 -0-- 0 0 10D-m 1.390 sw 38.92 20.03 0 0 0 0 0 0 0 0 4A5-2om 0.770 sw 21.56 19.31 0 0 0 0 0 0 0 0 11D0_ __.__. _._0.390_sw __ 10.92 1.1..31 _. .. 0 _ _ W 13A-0ocs 0.143 nw 4.00 2.55 0 0 0 0 - 0 0 0 0 _�--G 4A5-2om 21.56 36.90 _ _0 0 -- 0 0 0 p ono nw - 12C_Osw _ _._0 091 .__ _ _ _2.55 1.28 _ _ -- 0 .. _ 0 _ ..., .-:.0_ --...0 0: __ ..:0._ ---- 0 6 C 16B-30md 0.032_- 0.90 _1_68 21 21 19 35 132 132 118 - 222 22A-tpl.___._. __ _. _0.989 _ -- ---27.69_ ._0.00 _ .. .-21.- - e 0 -0 0 _ .132 _6_ 166 0 6 c)AED excursion -1 -13 Envelope loss/gain 19 35 691 572 12 a) Infiltration 0 0 108 29 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 19 35 799 601 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution % 0 0 0 0 14 Subtotal 19 35 799 601 15 Duct loads 28% 59% 5 20 28% 59% 224 355 Total room load 24 55 1023 956 Air required(cfm) 0 2 10 43 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed - wrightsoft- Right-Suite®Universal 2017 17.0.14 RSU08101 2017-Jan-30 11::09:233 ...Quick Calcs\Documents\HAYS-ST.LUCIE COUNTY.rup Calc=MJ8 Front Door faces: N 9 e 8 + -wrightsoft° Right-J®Worksheet Job: Entire House Date: Jan 30,2017 QUICK CALCS, INC. By. 317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone:772-466-6799 Fax 772-466-6796 Email:QUICKCALCS@,\OL.COM 1 Room name HALL 2 Exposed wall 0 ft 3 Room height 10.0 ft heat/cool 4 Room dimensions 1.0 x 63.0 ft ' 5 Room area 63.0 ftz 2 Ty Construction U-value Or HTM Area (W) Load Area Load number (13tuh/ftz-°F) (13tuh/ft� or perimeter (ft) (13tuh) or perimeter Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 - - -- 13A-4bcs - - -- - -- -0.143 ne -4.00- 255- ---- � --- - - 0--- - - �- - ---0 -- - - - - -- 4A5-2om 0.770 ne 21.56 - 36.90 - 0 0 0 0 4A5-2om 0.770 ne 21.56 36.90 0 0 0 0 4A5-2om 0.770 ne 21.56 36.90 0 0 0 0 11 4A5-2om. 0.770 ne 21.56 36.90 0 0 . 0 0 4A5-2om, 0.770 ne 21.56 36.90 0 0 0 0 11D0 .__._0.390. ne _10.92.--11.31-_ _-- 0--- -- -_0_-. -- 0 _- _-- _0_ _ -- -----_ W_ _ 13A-4ocs----- - - - -- - - - --- __ ___0.143, se_ _ ._ 4.00 _ _2.55_ __0 _ _0__ _ _ _ ___ 13A-4ocs 0.143 sw 4.00 2.55 0 0 0 0 10D-m 1.390 sw 38.92 20.03 0 0 0 0 .Vh 4A5-2om 0.770 sw 21.56 19.31 0 0 0 0 Al DO__ - -- -_ - 0.390-sw _10.92 ..- 11.31. -=-0 0 - 0 -._0 WI � 13A-4ocs 0.143 nw 4.00 2.55 0 0 0 0 _L-G _4A5-20m___ --. ---0,770-nw _ 2-t56__ 36.90_1 . ___.._0._ : _ .__0__._ .-� P 12C-0sw _._ - _. 0.091 - 2.55 .1.28_. _ 0. _ - _ 0._ - 0 0- C. ..._ 1613-30md-. - - -. _0.,032 0.90_ _1.68__ .__,63. 63 -..._ .. 56- - 1w- F -0.989 __- _ - 27.69 __0:00 630 0 0 6 c)AED excursion -2 Envelope loss/gain 56 104 12 a) Infiltration 0 0 b) Room ventilation 0 0 13 Internal gains: Occupants @ 230 0 0 Appliances/other 0 Subtotal(lines 6 to 13) 56 104 Less external load 0 0 Less transfer 0 0 Redistribution 0 0 14 Subtotal 56 104 15 Duct loads 28% 59% 16 61 Total room load 72 165 Air required(cfm) 1 7 'I Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. ,_Q � wrightsoft- Right-Suite®Universal 2017 17.0.14 RSU08101 2017-Jan-30 11:Page ge 9 9 'CC�'` ...Quick Calcs\DocumentslHAYS-ST.LUCIE COUNTY.rup Calc=MJ8 Front Door faces: N I i OFFICE USE ONLY: _ PERMIT# DATE FILED: yp _—_--- ___-- •o�.�' REVISION FEE: 11 !co RECEIPT# a. PLANNING&DEVELOPMENT SERVICES BUILDING&CODE REGULATION DIVISION 2300 VIRGINIA AVENUE FORT PIERCE,FL 349&-5652 (772)462-1553 APPLICATION FOR BUILDING PERMIT REVISIONS PROJECT INFORMATION 1. LOCATION/SITE ADDRESS: ?�(� S. fnr,�..S f1/�l� Kcl • y� ��P✓�-� ✓q(q� 2. DETAILED DESCRIPTION OF PROJECT REVISIONS: ���h D►p r'•�. - ,-[7 V � I�iv1u-� i l J rl�✓•. V l.t-�'r'.�? �'�/'� r 3. CONTRACTOR INFORMATION: STATE of FL REG./CERT.#: o S 37 ST.LUCIE COUNTY CERT.#. BUSINESS NAME: sue F-I-e QUALIFIERS NAME: r � ADDRESS: S7 roctL `v.� h f2 / CITY: i STATE: i= L ZIP: 41 9,*"S PHONE(DAYTIlVIE): S/G -055a FAX: 4. OWNER/BUILDER INFORMATION: NAME: ADDRESS: CITY: STATE: ZIP: PHONE: FAX: 5. ARCHITECT/ENGINEER INFORMATION: On I NAME: ADDRESS: CITY: STATE: PHONE(DAYTIME): i SLCCQ 9/23109 Revised 04/26/2010 90 I lEaIvlsloN 3232 SE.Dixie Hwy. GAS APPLIANCE INSIDE 13UILDING ENVELOPE,UG LINE 10 PSV INTERIOR 12'.TO 13'.WC nk p FERRELLGAS Stuarl,FL 34997 Me 772-287-4330 Fax 772-287-3456 n AUG OWNER: HAYS RESIDENCE St. LLir-lp- Fl- ADDRESS 2720 S.BROC6Mrffl RD. CITY FORT PIERCE STATE FLORIDA ZIP 34946 CONTACT JARED MOLINE-772-519-0558 BUILDER-CORE CONSTRUCTION FERRELLGAS BY JOSH CELL 239-300-3146 INSTALLATION TO BE MADE IN OCCORDANCE WITH NFPA 54 8 58 AS WELL AS ALL STATE AND LOCAL CODES OUTLETS 4 'j- TOTAL BTU'S 320,000 REGULATORS 1ST STAGE 522HGJ MEC 2NDSTAGE 662 HSRL MEC In sgk\k OrN UJ4*cr 0 TANK SIZE Soo A/G UIG xxx L to From Sowcc.bF- PAIR LENGTH 4' -HELIX 6" FORM R405-2014 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method F ' Project Name: HAYS RESIDENCE Builder Name: COLE CONSTRUCTION SERVICES LLC Street: 1720 S BROCKSMITH RD. AU `1 h 9 13ermit Office: ST.LUCIE COUNTY City,State,Zip: FT.PIERCE,FL, Permit Number:1702-0071 Owner: JODY&PETER HAYS PEF;:,,l TiN'rx Jurisdiction: Design Location: FL, Fort Pierce St. Lucie C;OUnnl,Cfwnty:: ST.LUCIE COUNTY(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types(2085.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Ext Insul,Exterior R=4.2 1985.00 ft2 b.Frame-Wood, Exterior R=11.0 100.00 ft2 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms 3 d.N/A R= ft2 5. Is this a worst case? No 10.Ceiling Types (2136.0 sqft.) Insulation Area a.Under Attic(Vented) R=30.0 2136.00 ft2 6. Conditioned floor area above grade(ft2) 2136 b.N/A R= ft2 Conditioned floor area below grade(ft2) 0 c.N/A R= ft2 11.Ducts R ft2 7. Windows(222.9 sqft.) Description Area a.Sup:Attic, Ret:Attic,AH:Garage 6 425 a. U-Factor: Dbl,U=0.65 222.91 ft2 SHGC: SHGC=0.25 b. U-Factor: N/A ft2 12.Cooling systems kBtu/hr Efficiency SHGC: a.Central Unit 41.0 SEER:16.00 c. U-Factor: N/A ft2 SHGC: 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a.Electric Strip Heat 34.0 COP:1.00 SHGC: Area Weighted Average Overhang Depth: 8.961 ft. Area Weighted Average SHGC: 0.250 14.Hot water systems 8. Floor Types (2136.0 sqft.) Insulation Area a.Propane Tankless Cap: 1 gallons a.Slab-On-Grade Edge Insulation R=0.0 2136.00 ft2 b. Conservation features EF:0.600 b.N/A R= ft2 None c.N/A R= ft2 15.Credits Pstat Glass/Floor Area: 0.104 Total Proposed Modified Loads: 71.35 PASS Total Baseline Loads: 72.96 1 hereby certify that the plans and specifications covered by Review of the plans and �eZHE Sp,�?� this calculation are in compliance with the Florida Energy specifications covered by this �+ , = z O� Code. calculation indicates compliance vj � with the Florida Energy Code. ti Hr,,,"rf��.. ::: •;;.� �„ O PREPA D B Before construction is completed . ,..:. .. DATE: - this building will be inspected for O T-lk compliance with Section 553.908 1166 I hereby certify that this building, as designed, is in compliance Florida Statutes. with the Florida Energy Code. G'OD WE OWNER/AGENT: BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification!by the air handler unit manufacturer that the air ha e a a certified factory-sealed in accordance with R403.2.2.1. s r -Compliance requires an Air Barrier and Insulation Inspection Checklist in acc : wit . 0 1. a n .#6 leakage test report in accordance with R402.4.1.2. 8/14/2017 9:56 AM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 6 FORM R405-2014 PROJECT Title: HAYS RESIDENCE! Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 2136 Lot# Owner: JODY&PETER HAYS Total Stories: 1 Block/SubDivision: #of Units: 1 Worst Case: No PlatBook: Builder Name: COLE CONSTRUCTION SER Rotate Angle: 0 Street: 1720 S BROCKSMITH Permit Office: ST. LUCIE COUNTY Cross Ventilation: No County: ST.LUCIE COUNTY Jurisdiction: Whole House Fan: No City,State,Zip: FT.PIERCE, Family Type: Single-family FL, New/Existing: New(From Plans) Comment: CLIMATE / IECC Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site Zone 97.5% 2.5% Winter Summer Degree Days Moisture Range FL,Fort Pierce FL_VERO_BEACH_MUNI 2 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 2136 21810 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 MUD ROOM 101 1010 No 0 1 Yes Yes Yes 2 LAUNDRY 42 420 No 0 1 Yes Yes Yes 3 PANTRY 63 630 No 0 1 Yes Yes Yes 4 WIC 2 66 660 No 0 1 Yes Yes Yes 5 MASTER BEATH 176 1760 No 0 1 Yes Yes Yes 6 MASTER BEDROO 231 2310 No 1 1 1 Yes Yes Yes 7 WIC 77 770 No 0 1 No Yes Yes 8 KITCHEN 270 2700 Yes 0 1 Yes Yes Yes 9 GREAT ROOM 450 4950 No 2 1 Yes Yes Yes 10 BEDROOM 3 168 1680 No 1 1 1 Yes Yes Yes 11 BATH#3 48 480 No 0 1 Yes Yes Yes 12 BATH 3 48 480 No 0 1 Yes Yes Yes 13 BEDROOM 2 180 1800 No 1 1 1 Yes Yes Yes 14 POWDER 21 210 No 0 1 No Yes Yes 15 FOYER 132 1320 No 0 1 Yes Yes Yes 16 HALL 63 630 No 0 1 No Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab-On-Grade Edge Insulatio MUD ROOM 21 ft 0 101 ftZ ---- 0 1 0 2 Slab-On-Grade Edge Insulatio LAUNDRY 7 ft 0 42 ftZ ---- 0 1 0 8/14/2017 9:56 AM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 6 I FORM R405-2014 FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 3 Slab-On-Grade Edge Insulatio PANTRY 4 ft 0 63 ft2 ---- 0 1 0 4Slab-On-Grade Edge Insulatio WIC 2 6 ft 0 66 ft2 ---- 0 1 0 5 Slab-On-Grade Edge Insulatio MASTER BEATH 27 ft 0 176 ft2 ---- 0 1 0 6 Slab-On-Grade Edge Insulatio MASTER BEDRO 14 ft 0 231 ft2 ---- 0 1 0 7 Slab-On-Grade Edge Insulatio WIC 1 ft 0 77 ft2 ---- 0 1 0 8 Slab-On-Grade Edge Insulatio KITCHEN 18 ft 0 270 ft2 ---- 0 1 0 9 Slab-On-Grade Edge Insulatio GREAT ROOM 45 ft 0 450 ft2 ---- 0 1 0 10SIab-On-Grade Edge Insulatio BEDROOM 3 14 ft 0 168 ft2 ---- 0 1 0 11SIab-On-Grade Edge Insulatio BATH#3 14 ft 0 48 ft2 ---- 0 1 0 12SIab-On-Grade Edge Insulatio BATH 3 6 ft 0 48 ft2 ---- 0 1 0 13SIab-On-Grade Edge Insulatio BEDROOM 2 12 ft 0 180 ft2 ---- 0 1 0 14SIab-On-Grade Edge Insulatio POWDER 1 ft 0 21 ft2 ---- 0 1 0 15SIab-On-Grade Edge Insulatio FOYER 6 ft 0 132 ft2 ---- 0 1 0 16SIab-On-Grade Edge Insulatio HALL 1 ft 0 63 ft2 ---- 0 1 0 ROOF / Roof Gable Roof Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Hip Composition shingles 2251 ft2 0 ft2 Light 0.6 No 0.9 No 0 18.4 ATTIC V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC 1 Full attic Vented 150 2136 ft2 N N 8/14/2017 9:56 AM EnergyGaugeO USA-FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 6 FORM R405-2014 CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic(Vented) MUD ROOM 30 Blown 101 ft2 0.1 Wood 2 Under Attic(Vented) LAUNDRY 30 Blown 42 ft2 0.1 Wood 3 Under Attic(Vented) PANTRY 30 Blown 63 ft2 0.1 Wood 4 Under Attic(Vented) WIC 2 30 Blown 66 ft2 0.1 Wood 5 Under Attic(Vented) MASTER BEATH 30 Blown 176 ft2 0.1 Wood 6 Under Attic(Vented) MASTER BEDRO 30 Blown 231 ft2 0.1 Wood 7 Under Attic(Vented) WIC 30 Blown 77 ft2 0.1 Wood 8 Under Attic(Vented) KITCHEN 30 Blown 270 ft2 0.1 Wood 9 Under Attic(Vented) GREAT ROOM 30 Blown 450 ft2 0.1 Wood 10 Under Attic(Vented) BEDROOM 3 30 Blown 168 ft2 0.1 Wood 11 Under Attic(Vented) BATH#3 30 Blown 48 ft2 0.1 Wood 12 Under Attic(Vented) BATH 3 30 Blown 48 ft2 0.1 Wood 13 Under Attic(Vented) BEDROOM 2 30 Blown 180 ft2 0.1 Wood 14 Under Attic(Vented) POWDER 30 Blown 21 ft2 0.1 Wood 15 Under Attic(Vented) FOYER 30 Blown 132 ft2 0.1 Wood 16 Under Attic(Vented) HALL 30 Blown 63 ft2 0.1 Wood WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below SpaceR_VaArea Ft In R-Value 1 E Exterior Concrete Block-Ext InsMUD ROOM 4.2 10 0 10 0 100.0 ft2 0 0 0.6 0 2 S Exterior Concrete Block-Ext InsMUD ROOM 4.2 1 0 10 0 10.0 ft2 0 0 0.6 0 3 W Exterior Concrete Block-Ext InsMUD ROOM 4.2 10 0 10 0 100.0 ft2 0 0 0.6 0 4 W Exterior Concrete Block-Ext Insi1LAUNDRY 4.2 7 0 10 0 70.0 ft2 0 0 0.6 0 5 S Exterior Concrete Block-Ext InsuPANTRY 4.2 4 0 10 0 40.0 ft2 0 0 0.6 0 6 S Exterior Concrete Block-Ext Insul WIC 2 4.2 6 0 10 0 60.0 ft2 0 0 0.6 0 7 E Exterior Concrete Block-Ext InsMASTER BE 4.2 11 0 10 0 110.0 ft2 0 0 0.6 0 8 S Exterior Concrete Block-Ext IndUASTER BE 4.2 16 0 10 0 160.0 ft2 0 0 0.6 0 9 E Exterior Concrete Block-Ext Ins)JASTER BE 4.2 14 0 10 0 140.0 ft2 0 0 0.6 0 10 W Exterior Concrete Block-Ext InsuKITCHEN 4.2 18 0 10 0 180.0 ft2 0 0 0.6 0 11 N Exterior Concrete Block-Ext InGREAT ROO 4.2 15 0 11 0 165.0 ft2 0 0 0.6 0 _12 W Exterior Concrete Block-Ext InGREAT ROO 4.2 30 0 11 0 330.0 ft2 0 0 0.6 0 13 N Exterior Concrete Block-Ext Ind3EDROOM 3 4.2 14 0 10 0 140.0 ft2 0 0 0.6 0 _14 N Exterior Concrete Block-Ext.InsuBATH#3 4.2 8 0 10 0 80.0 ft2 0 0 0.6 0 15 E Exterior Concrete Block-Ext InsuBATH#3 4.2 6 0 10 0 60.0 ft2 0 0 0.6 0 16 E Exterior Concrete Block-Ext Insul BATH 3 4.2 6 0 10 0 60.0 ft2 0 0 0.6 0 17 E Exterior Concrete Block-Ext InJIffDROOM 2 4.2 12 0 10 0 120.0 ft2 0 0 0.6 0 18 E Exterior Concrete Block-Ext Insul FOYER 4.2 6 0 10 0 60.0 ft2 0 0 0.6 0 19 N Exterior Frame-Wood MUD ROOM 11 10 10 100.0 ft2 0.23 0.6 0 8/14/2017 9:56 AM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 6 FORM R405-2014 j DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 W Insulated MUD ROOM None .39 2 10 8 22.7 ftZ 2 E Insulated FOYER None .39 3 8 24 ftZ WINDOWS Orientation shown is the entered,Proposed orientation. Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening 1 E 1 Metal Low-E Double Yes 0.65 0.25 12.0 ftZ 12 ft 0 in 1 ft 4 in None None 2 E 7 Metal Low-E Double Yes 0.65 0.25 9.0 ftZ 2 ft 0 in 1 ft 4 in None None 3 E 9. Metal Low-E Double Yes 0.65 0.25 28.3 ftz 6 ft 0 in 1 ft 4 in None None 4 W 10 Metal Low-E Double Yes 0.65 0.25 24.0 ft2 12 ft 0 in 1 ft 4 in None None 5 W 12 Metal Low-E Double Yes 0.65 0.25 96.0 ftz 12 ft 0 in 1 ft 4 in None None 6 N 13 Metal Low-E Double Yes 0.65 0.25 15.0 ftz 2 ft 0 in 1 ft 4 in None None 7 E 15 Metal Low-E Double Yes 0.65 0.25 9.0 ftz 2 ft 0 in 1 ft 4 in None None 8 E 17 Metal Low-E Double Yes 0.65 0.25 14.6 ftz 6 ft 0 in 1 ft 4 in None None 9 E 17 Metal Low-E Double Yes 0.65 0.25 15.0 ftZ 6 ft 0 in 1 ft 4 in None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation 1 140ft2 140ft2 loft loft 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000454 2544.5 139.69 262.71 .3315 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Strip Heat None COPA 34 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit Split SEER: 16 41 kBtu/hr cfm 0.8 1 sys#1 HOT WATER SYSTEM # System Type SubTpe Location EF Cap Use SetPnt Conservation 1 Propane Tankless Garage 0.6 1 gal 60.9 gal 120 deg None I 8/14/2017 9:56 AM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 5 of 6 FORM R405-2014 SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model# Collector Model# Area Volume FEF None None ft2 DUCTS / —Supply— —Return— Air CFM 25 CFM25 HVAC# # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 425 ft2 Attic 105 ft2 Default Leakage Garage (Default) (Default) 1 1 TEMPERATURES Programable Thermostat:Y Ceiling Fans: CoolingJan Feb Mar Apr Ma rj Jun rl Jul ri Au rl Se Oct Nov Dec Heatin Jan Feb Mar E Apr I May Jun Jul AuSeP Oct Nov Dec Ventin Jan Feb X Mar [X]A r May Jun Jul Aug Se [Xl Oct HX Nov H Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 8/14/2017 9:56 AM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 6 of 6 FORM R405-2014 TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: HAYS RESIDENCE Builder Name: COLE CONSTRUCTION SERVICES LLC Street: 1720 S BROCKSMITH RD. Permit Office: ST.LUCIE COUNTY City,State,Zip: FT.PIERCE, FL, Permit Number:1702-0071 Owner: JODY&PETER HAYS Jurisdiction: Design Location: FL, Fort Pierce COMPONENT CRITERIA CHECK Air barrier and thermal barrier A continuous air barrier shall be installed in the building envelope. Exterior thermal envelope contains a continuous barrier. Breaks or joints in the air barrier shall be sealed. Air-permeable insulation shall not be used as a sealing material. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the insulation and any gaps in the air barrier shall be sealed. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Corners and headers shall be insulated and the junction of the foundation Walls and sill plate shall be sealed. The junction of the top plate and the top or exterior walls shall be sealed. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Knee walls shall be sealed. Windows, skylights and doors The space between window/doorjambs and framing and skylights and framing shall be sealed. Rim joists Rim joists are insulated and include an air barrier. Floors (including above-garage Insulation shall be installed to maintain permanent contact with underside and cantilevered floors) of subfloor decking. The air barrier shall be installed at any exposed edge of insulation. Crawl space walls Where provided in lieu of floor insulation, insulation shall be permanently attached to the crawlspace walls. Exposed earth in unvented crawl spaces shall be covered with a Class I vapor retarder with overlapping joints taped. Shafts, penetrations Duct shafts, utility penetrations,and flue shaft openings to exterior or unconditioned space shall be sealed. Narrow cavities Batts in narrow cavities shall be cut to fit, or narrow cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal envelope shall be air tight, IC rated,and sealed to the drywall. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind piping and wiring. Shower/tub on exterior wall Exterior walls adjacent to showers and tubs shall be insulated and the air barrier installed separating them from the showers and tubs. Electrical/phone box on The air barrier shall be installed behind electrical or communication boxes or air sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub-floor or drywall. Fireplace An air barrier shall be installed on fireplace walls. Fireplaces shall have gasketed doors 8/14/2017 9:56 AM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 1 FORM R405-2014 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 98 The lower the EnergyPerformance Index, the more efficient the home. 1720 S BROCKSMITH RD. FT. PIERCE FL 1. New construction or existing New(From Plans) 9. Wall Types Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Ext Insul,Exterior R=4.2 1985.00 ftz b.Frame-Wood,Exterior R=11.0 100.00 ftz 3. Number of units,if multiple family 1 c.N/A R= ftz 4. Number of Bedrooms 3 d. N/A R= ftz 5. Is this a worst case? No 10.Ceiling Types Insulation Area a.Under Attic(Vented) R=30.0 2136.00 ftz 6. Conditioned floor area(ftz) 2136 b.N/A R= ftz _ z 7. Windows** Description Area 11 Ducts R R ftz SH SHGC: SHGC=0.25 a. U-Factor: U=0.65 222.91 ftz a.Sup:Attic,Ret:Attic,AH:Garage 6 425 b. U-Factor: N/A ftz SHGC: 12.Cooling systems kBtu/hr Efficiency c. U-Factor: N/A ftz a.Central Unit 41.0 SEER:16.00 SHGC: d. U-Factor: N/A ftz 13.Heating systems kBtu/hr Efficiency SHGC: a.Electric Strip Heat 34.0 COP:1.00 Area Weighted Average Overhang Depth: 8.961 ft. Area Weighted Average SHGC: 0.250 8. Floor Types Insulation Area 14.Hot water systems Cap: 1 gallons a.Slab-On-Grade Edge Insulation R=0.0 2136.00 ftz a.Propane EF:0.6 b.N/A R= ftz c.N/A R= ftz b. Conservation features None 15.Credits Pstat I certify that this home has complied with the Florida Energy Efficiency Code for Building ZgE ST Construction through the above energy saving features which will be installed (or exceeded) tiO4 = ApFo in this home before final inspection. Otherwise, a new EPL Display Card will be completed s, based on installed Code compliant features. �. ,,,,,,., �-. =; ••,..•, o Builder Signature: Date: Address of New Home: City/FL Zip: CAD WE *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage(EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at(321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 8/14/2017 9:56 AM EnergyGauge@)USA-FlaRes2014 -Section R405.4.1 Compliant Software Page 1 of 1 i