HomeMy WebLinkAbout5V CRIMP (EXTREME) revision11/9/2020 Florida Building Code Online
Ir
�,j,�`i b a1 d,y i�pdgd Ill
��Product Approval
p r\\\iii USER: Public User
ProdApproval Menu > Product or ApyGcazlun Search > Applleallon List > Application Detail
FL #
FL17022-R7
Application Type
Revision
Code Version
2017
Application Status
Approved
Comments 08/18/2017v. date reapply 08/21/17
Archived
Product Manufacturer Extreme Metal Fabricators, LLC
Address/Phone/Email 2160 SW Poma Drive
Palm City, FL 34990
(772) 872-8034
flvalidation@yahoo.com
Authorized Signature
Richard McKuhen
fiva I idation@ ya hoo. com
Technical Representative
Richard McKuhen
Address/Phone/Email
2160 SW Perna Drive
Palm City, FL 34990
(772)872-8034
richard@emfab.net
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Metal Roofing
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed the LOCKE BOWDEN
Evaluation Report
Florida License
PE-49704
Quality Assurance Entity
Keystone Certifications, Inc.
Quality Assurance Contract Expiration Date
04/22/2024
Validated By
Zachary R. Priest, P.E.
I Validation Checklist - Hardcopy Received
Certificate of Independence
Referenced Standard and Year (of Standard)
Equivalence of Product Standards
Certified By
FL17022 R7 COI FL 17022.1 5 V CRIMP ssr.W
Standard
TAS 125
UL 1897
UL 580
Year
2003
2012
2006
Sections from the Code
https://www.floridabuilding.org/prlpr_app_dtl.aspx?param=wGEVXQwtDgv2aBQpHpQQe6rMZMkUEoR%2bGxHGxFe5QkCHzEgvOQveeg%3d%3d 1/3
11/9/2020
Florida Building Code Online
Product Approval Method
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
Date Revised
Method 1 Option D
08/18/2017
08/25/2017
08/28/2017
10/10/2017
10/05/2020
IDif„_ I Model, Number or Name I Description
17022.1 ) 11 - "5V Crimp" (116)
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: No
Design Pressure: +N/A/ -Table A
Other: Refer to evaluation report for conditions. Install the
assembly In compliance with the installation method listed in
this report and applicable code sections of FBC. Refer to
manufacturer's Installation instructions.
17022.2 12 - "5V Crimp" (R6)
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: No
Design Pressure: +N/A/ -Table A
Other: Refer to evaluation report for conditions.Install the
assembly in compliance with the installation method listed in
this report and applicable code sections of FBC. Refer to
manufacturer's Installation instructions.
26 Gauge steel, 3/8" rib height, 24" wide lapped roof panel
mechanically attached to 15/32" plywood or Wood Deck with
fasteners
Installation Instructions
FL17022 R7 II FL 17022,1 5 V CRIMP ssr.pi f
Verified By: Locke Bowden, P.E. 49704
Created by Independent Third Party: Yes
Evaluation Reports
FL17022 R7 AE FL 17022.1 5 V CRIMP ssr pd(
Created by Independent Third Party: Yes
0.032" Aluminum, 3/8" Rib height, 21" wide lapped roof panel,
mechanically attached to 15/32" plywood or Wood Deck with
exposed fasteners
Installation Instructions
FL17022 R7 II FL 17022.2 5 V CRIMP 0.032 ALUM ssrpif
Verified By: Locke Bowden, P.E. 49704
Created by Independent Third Party: Yes
Evaluation Reports
FL17022 R7 AE. EL. 17022.2 5 V CRIMP 0.032 ALUM sscgd
Created by Independent Third Party: Yes
17022.3 3 - "1.5" Mechanical Seam" (115) 1.5" rib height, 16" wide, 24 gauge steel, standing seam roof
panel mechanically attached to 15/32" plywood or wood deck
with clips and fasteners.
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL17022 R7 II FL 17022,3 1.5 MECHANICAL
Approved for use outside HVHZ: Yes seam 2493 ssr.pdf
Impact Resistant: No Verified By: Locke Bowden, P.E. 49704
Design Pressure: +N/A/ -Table A Created by Independent Third Party: Yes '
Other: Refer to evaluation report for conditions and limitations Evaluation Reports
of use. Install the assembly in compliance with the Installation FL17022 R7 AE FL 17022.3 1.5 MECHANICAL
method listed in this report and applicable code sections of seam 24gi3`ir.pd-f
FBC. Refer to manufacturer's installation instructions. Created by Independent Third Party: Yes
17022.4 4 - "1.5" Mechanical Seam" (RS) 1.5" rib height, 16" wide, 0.032" aluminum, standing seam roof
panel mechanically attached to 15/32" plywood or Wood Deck
with clips and fasteners.
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
EL17022 R7 II FL 17022.4 MECHANCIAL SEAM
Approved for use outside HVHZ: Yes
ALUMINUM ssrpd(
Impact Resistant: No
Verified By: Locke Bowden, P.E. 49704
Design Pressure: +N/A/-TableA
Created by Independent Third Party: Yes
Other: Refer to evaluation report for conditions and limitations
Evaluation Reports
of use. Install the assembly in compliance with the Installation
FL17022 R7 AE FL 17022.4 MECHANCIAL SEAM
method listed in this report and applicable code sections of
ALUMINUM ssnRdf
FBC. Refer to manufacturer's installation instructions.
Created by Independent Third Party: Yes
17022.5 15 - "1 in. Nail Strip" (115)
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: No
Design Pressure: +N/A/ -Table A
Other: Refer to evaluation report for conditions and limitations
of use. Install the assembly in compliance with the Installation
1" rib height, 16" wide, 26 gauge steel, standing seam roof
panel mechanically attached to 15/32" plywood or wood deck
with fasteners.
Installation Instructions
FL17022 R7 II FL 17022.5 1.0 NAILSTRIP ssr.pdf
Verified By: Locke Bowden, P.E. 49704
Created by Independent Third Party: Yes
Evaluation Reports
FL17022 R7 AE FL 17022 5 1,0 NAILSTRIP ssr pdf
Created by Independent Third Party: Yes
https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgv2aBQpHpQQe6rMZMkUEoR%2bGxHGxFeSOkCHzEgvOQveeg"/u3d°/n3d 213
Palm City, FL 34990
(772)872-8034
Compliant with Florida Building Code 2017 (6th ed.)
Compliant with Florida Product Approval Rule # 61G2O-3
Compliant: Keystone Certifications
Product: 5 V Crimp 26GA Steel Roof Panel FBC Sec. 1507.4.2
Yield strength: 50 ksi min.; Attached to min. 15/32" plywood or Wood
Deck w/ min. 0.42 specific gravity with screws. 24" Coverage
Rib Height 3/8"
Corrosion Resistant Compliant: FBC Sec. 1507.4.3
Fastener 1 (Method 1 Attachment): #9 x 1-1/2" Hex -Washer Head wood screw* to penetrate
3/16" min. thru deck or 5/8" embedment into wood plank. (*or sufficient length to meet
requirements)
Fastener 2 (Method 2,3, & 4 Attachment): #10 x 1-1/2" Hex -Washer Head wood screw* to
penetrate 3/16" min. thru deck or 5/8" embedment into wood plank. (*or sufficient length
to meet requirements)
Underlayment: To be compliant with FBC Sec. Chart 1507.1.1
Slope: Shall be in compliance with FBC Sec. 1507.
See Fastener attachment specifications above
Install Details: Table A Allowable Loads
METHOD 1
METHOD 2
METHOD 3
METHOD 4
DESIGN PRESSURE*
-86 PSF
-93.5 PSF
-101 PSF
-228 PSF
ROW SPACING
16" o.c.
16" o.c.
8" O.C.
6" o.c.
FASTENER SPACING (ALONG Panel width)
12" o.c.
12" o.c.
12" o.c.
12" o.c.
FASTENER SIZE
#9
#10
#10
#10
Reference Data: ARCHITECTURAL TESTING, INC. TST ID#: 1527
UL 580-06 & 1897-041 Test Report 005893.01-450-18 05/02/14
Test Report F3366.01-450-18 12/18/15
TAS 125-03 Test Report D05893.02-450-18 07/22/14
*EQUIVALENCY-UL 1897-04 is equivalent to test standard UL 1897-1 ?f i IF If,. *Design pressure margin of safety 2:1
D r 0,
Locke Bowden, P.E. does not have, not will acquire a financial intpl' +lq 0JC�cq j »n'm�f4+facturing or distributing products
under this evaluation. • "
Locke Bowden, P.E. is not owned, operated, or controlled by ady cotnparfVpn 4b06atur;r, or Elstributing products under this
report.
/717
m
v ,
FL17022.1 5V Crimp (26GA Steel), 24" Wide Roof Panel -Details
Limitations:
1. Underlayment to be compliance with current Florida Building Code (FBC)2017 6th ed.
2. Minimum slope to be compliant with Florida Building Code 2017 61h ed., and per with Manufacturer's installation reference.
3. Products are compliant for State of Florida product approval per Rule 61 G20-3. Compliance Method: 1-D
4. Engineering analysis for "project specific approval by local authorities w/jurisdiction is allowed by other registered engineers.
5. Fire classification is not part of this acceptance. Shear diaphragm values are outside this report.
6. Support framing in compliance w/FBC 2017 6th ed., Chapter 22 for Steel, Chapter 23 for Wood and Chapter 16 for
Structural Loading.
7. This report does not imply warranty, installation, recommended product use outside of this report.
A_
441
Deck:
-15132" or greater Plywood, or
- Wood plank
- Fasteners -
#9 x 1-112" Min. or
#10 x 1-112" Min. pw7We'AR for Row 5-V Crimp Roof Panel
Spacing and Design Pressures
Hex Washer Head Wood Screws
OPTIONAL STRIATIONS
Panel Profile
Nominal 12" Nominal 12"
O.C. O.C.
Fasten
9 x 1-1/2" Min. or #10 x 1-112" Min. per
-Table "A" Hex Washer Head Screw
Spaced 12" o.c. across the Panel Width
Panel Refer to Table "A" for Spacing Along Panel
Overlap Length
Deck-15132" or greater
Plywood, or
-1Nbod plank