Loading...
HomeMy WebLinkAboutLetter; Design Loads7ft ri iroo-01UL-0-F srarESon NOVEMBER 8, 1995 MR. PHILL DRAWDY 1216 BELL AVE. FORT PIERCE, FL. 34982 MANUFACTURERS, INC. POST OFFICE BOX 1128 STARKVILLE, MISSISSIPPI39759 TELEPHONE (601) 323-8021 FAX (601) 324-2984 RE: MR. PHIL DRAWDY 800 EDWARDS RD. FORT PIERCE, FL. 34982 GSM Job# 30123 RF 70 x 95 x 20 E.H. SSRF 20 x 40 x 14-4 L.S.E.H. RF 70 x 105 x 20 E.H. Gentlemen: In accordance with purchase order documents, the referenced structure has been designed to withstand the loads as listed. The loads were applied as recommended by the Standard Building Code, Southern Building Code Congress International, Incorporated, 1991 Edition. In addition to the dead load of the building components, the design loads are as follows: ROOF LIVE LOAD Primary Framing 12 psf Secondary Framing 20 psf GROUND SNOW LOAD 0 psf Exposure Factor NA WIND SPEED 110 mph Exposure Factor C SEISMIC ZONE 0 COLLATERAL LOAD 0 psf BUILDING USE CATEGORY I The building was designed in accordance with design specifications in the Ninth Edition of AISC Manual of Steel Construction and the 1986 Edition with 1989 Addendum of the AISI. Gulf States Manufacturers, Inc. is an approved manufacturer in the AISC Quality Certification Program in the category of Metal Building Systems. The design of accessories such as doors, windows, translucent panels, louvers and ventilators are not included with respect to properties or use regardless of their source. Other parts of the project such as the foundation, existing buildings, masonry walls, mechanical equipment and erection of the building components are not part of the design by Gulf States Manufacturers, Inc. Effects on the building due to the excluded items that fail to withstand their required loads are not covered in this letter. The building components should be erected in accordance with the referenced job number erection drawings on a properly designed foundation with anchor bolts of the diameter(s) and yield strength shown on the Gulf States anchor bolt plan. Field inspection of materials which are provided by Gulf States is the responsibility of the erector and/or overall project professionals. The foundation designer will find the column reactions with the referenced job anchor bolt setting plans. To the best of my knowledge this design conforms with the load requirements of the building code and purchase order documents as previously stated. The undersigned is not the engineer for the overall project. Sincerely: GULF STATES MANUFACTURERS, INC. James E. Hulton, P. E. Design Engineer lmc Enclosures (2) NOV .8 MANUFACTURERS OF METAL BUILDING SYSTEMS