Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Project Information
waghtscft Project Summary oate: Entire House sY QUICK CALLS, INC. 317 ST. LUCIE L'N., Fr. PIERCE, FL,34946 PFane:.772-466.6799 Fax: 772-466.-6796 Email: QUICKCALCS@AOL.COM For: THE GRAND:CARLTON.IMPACT :. WYNNE DEVELOPMENT, FT PIERCE, FL Notes: ��9 Design Information Weather: Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db 70 OF Inside.db 75 OF Design TD 28 OF Design TD 15 OF Daily range L Relative humidity 50 % Moisture difference 61 grAb Heating Summary Sensible Cooling Equipment Load Sizing Structure 17848 Btuh Structure 17520 Btuh Ducts 5654 Btuh Duds 8536 Btuh Central vent (0 drn) 0 Btuh Central: vent (0 cfm) 0 Btuh (none) e) 0 . Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 23503 Btuh Use manufacturer's data n Rate/swin multiplier EquiprhN load 0.95 Infiltration sensible 24753 Btuh Method i Simplified .Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 3203 Btuh Duds . 2318 Btuh Central vent (0 cfm) 0 Btuh Heatingg Coolingg -(none) . Area (ftz) 1446 1446 Equipment latent load 5521 Btuh Volume (iN) 12511 12511 Airchangesmour OA5 0.23 Equipment Total Load (Sen+Lat) 30274 Btuh EquiuAVF (ch) 94 48 Req. total capadty at 0.70 SHR 2.9 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier . - Trade CARRIERAIR CONDITIONING Model 25HSC536KO80: AHRI ref 7914585 Efficiency Heating input - Heating output Temperature rise Actual airflow Air flow factor Static pressure Space thermostat Capacity balance point = 32 OF Backup: 8.5 HSPF 34600 Btuh @ 47°F 1160� 0.049 cfm/Btuh 0.50 in H2O Input = 7 kW, Output = 23009 Btuh;100 AFUE Make Carrier Trade CARRIERAIR CONDITIONING Cond 251-113CMW030 . Coil FX4DN(B;F)037 AHRI ref 7914585 Efficiency 12.0 EER,15 SEER Sensible cooling 24360 Btuh Latent cooling 10440 Btuh Total cooling 34800 Btuh Actual airflow 1160 cfm Airflowfactor 0.045 cfTVBtuh Static pressure 0.50 in H2O Load sensible heat ratio 0A3 Calculations approved byACCAto meet all requirements of Manual J 8th.Ed. -06+ �y�jgjt#S�pf�® 2020-JarF081620.47 n Riglt-Sute®Uriversa1201919.0.07 RSU08101 Page 1 igltsoftWAMTHEGRAND CARLTON-1446-IMPACT.rnp Calc=MJ8 FrontDoorfaces: N +W,righbww Right4@ Worksheet Job: Entire House Date: By. QUICK CALLS, INC. 317 ST. LUCIE LN., Fr.. PIERCE, FL 34946 Phone:772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@/,OL.COM 1 Room name Entire House BEDROOM 2 . Exposed wall 1562 ft 49.0 ft 3 Room height 8.7 It d 8.0 It heat/000l 4 5 Room dimensions Room area 1445.5 1 1.0 x 297.0 ft 297.0 ft2 Ty Construction U-value Or HTM Area . (ft) Load Area (il) Load number (Btuh/ _.F) (Btuh/ft.) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross NIPS Heat Cool Gross NIPS Heat Cool 6 W. 13A-flocs 0143 n -:4.00 2 55 50.3 465 1862 1184 . 72 72 268 183 4Ar2om 13A4ocs 0.7-70 0.143 ' .n a 21:56 4.00 `19.31 2S5 38 128 . 0 83 815 333 730 212 '. 0' 0 ' 0 0 : 0 0 : 0 0 1Ac1om 1270 a 35.56 8729 24 2 848 2082 0 0 0 0 D 11 11DO 0.390 a 10.92 11.31 21 21 229 238 0 0 0 0 W '.. , 1L13A-4ocs -.13A-flocs 0.143 0.143 se s 4.00 4.00 2.55 2.55 34 360 : 34 353 136. 1414 86 899 0 216 0 216 0 865 , 0 550 -G 1Ac1om 1270 s 35.56 34.77 7 7 247 241 0 0 0 0 G 13A-06cs 1Ac1om. 0143 1270 vv -.. w 4:00: 35.56 2.55 �6521 310 32 237 . 2 949 1140 603 1770 104 .32 72 2 288 1140 183 1770 4A6.2om' . 12C-Osw. . . 0.770 0.091 ' w 21.56 2.55 . 19.31 128 41 192 41 192 880 489 788 246 0 0 0 0 0 0 . 0 0 P C .16A30md 0.032 0.96 , 2.32 1446 1446 1295. 3354 297 297 266 689 F 22A-tpl 0.989 27.69 0.00 1446 156 4325 0. 297 49 1357 0, 6 c) AED excursion 918 627 Envelope loss/gain 14961 13349 4204 Q03 12 a) Infiltration 2887 791 848 232 b) Room ventilation 0 0 0 0 13 Internal gains: Oocupanb@ 230 6 1380 3 690 Applianoes/other 2000 0 Subtotal (lines 6 to 13) 17848 17520 5053 4925 Less exlemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subotal 17848 17520 5053 4925 151 Dud loads 32% 49% 5654 8536 32% 490/o 1601 2400 Total room load 23503 26056 6653 7325 Air required(cfm) 11601 1160 328 326 Calculations aDoroved bvACCA to meet all reaulrements of Manual J 8th Ed. wr �iglaL.of t� 2020-Jarr081620:47 Right SuteO Uriversal 201919.0.07 RSU08101 ACX;k_ Page 1 ighlsoftWAC1THEGRAND CARLTON-1.446-IMPACT.np Calc=MJ8 Front Door faces: N - - wrighuar Right-M Worksheet Job: Entire House Date` QUICK CALCS, INC. By 317 ST. LUCIE LN., FT. PIERCE. FL 34946 Phone:772-466-6799 Fax 772-466-6796 Email: QUICKCALCS a,40L.COM 1 Room name WIC KITCHEN 2 Exposed wall O ft O ft 3 Room height 8D ft heaV000l 8.0 ft heat/cool 4 5 Room dimensions Room area 6D x 9.0 It 54.0 ft2 1.0 x 172.0 ft 172.0 ftz Ty Construction U-value Or HTM Area Area(" Load number (Btuh&-.*F) (Btuhfll� or perimeter (ft) (tuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 V�/ G 13AAocs - ::4A5 tom 13AAo s 0.M 0.770 0.143 :. n n' a 4.00 21".56. 4.00 .: 2.55 19.31 2.55 : 0 : 0: 0 0 0 0 0. 0. 0 0 0 0 0 0 0 0 0 0 0 0 0. 0 0 0 W 11 IA-c1om 11DO 1270 0.390 a a 35.56 10.92 8729 11.31 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 -IL--G D W t13AAocs 13AAocs 0.143 0.143 1270 'se s s 4.00 4.00 35.56 , 2:55 2.55 34.77 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 .0 0 0 0 0 0 -G1Aclom �13X46cs G IA-c1om 0.143 1270 -'w w 4.00 35.50 2.55 5521 0. 0 .0 0 0 0 0 0. 0 p 0 0 0.. 0 0 0 c--G P .4A5-2om . 12C-Osw . 0.770 0.091 w - 21.56 2.55 1931: 128 0. 0 0 0 0 0 .0 0 0 64 0 64 0 163 0 82 C : •16A-30md 0.032 - . 0.90. 2.32 54 54 48 125 172 172 154 399 F 22A tpl 0.989 - 27.69 0.00 54 0 . 0 0 172 0 0 . 0 6 c) AED excursion -9 -170 Envelope losstgain 48 117 317 311 12 a) Infillration 0 0 0 0 b) Roomventiation 0 0 0 0 13 Internal gains: Occupants@ 230 0 0 0 0 Appllances/other 01 1 2000 Subtotal (lines 6 to 13) 48 117 317 2311 Less exlemal load 0 0 0 0 Lesstransfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 48 117 317 2311 15 Ductloads 32% 49% 15 57 32% 49% 100 1126 FfTotal room load 64 174 418 3437 Air required (dm) 3 8 21 153 Calculations approved byACCAto meet all requirements of Manual J 8th'Ed. - wrigllalso!'t ° . 2020-Jan•0816:20:47 Rigtt-Scite®Uriversai 201919.0.07 RSU68101 IghtsoftHVAC1THE GRAND CARLTON-1446-1MPACT.r p Calc= W8 Front boor faces: N Pege 2 - t- vurigtitfsoft� Right-J@ Woftheet Date Entire House °ate QUICK CALLS, INC. By: 317 ST. LUCIE LN., Fr.. PIERCE, FL 34946 Phone: 772466-6799 Fax 772-466-6796 Email: QUICKCALCS@J10L.COM 1 Room name BATH B®ROOM2 2 .E)posed vuall 5.0 it 342 It 3 Room height 8D It heaU000l 8D It heaUcool 4 5 Room dimensions Room area 9.0 x 5.0 It 45.0 f' 1D x 203.5 It 203.5 ftZ Ty Construction U-value Or HTM Area (ff) Load s number (BtuKV--°F) (Btu hllF) or perimeter r (ft) (Btuh) or perimeter (ft) (BWh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 yJ L ' 'G 13AAoss W-26m ..... 0.143 0.770 n ,n 4:00, 21:56: 2.55 " . 19.31 40 . 0 40 .. 0 160 .. 0 102 0 128 0 128 : -0 513 -" "o 326. 1. 0. 13AAo s 0.143 a 4.00 2.55 0 0 0 0 80 56 225 143 11 1A-clom 11DO 1270 0.390 a a 35.56 %92 8729 11.31 0 0 0 0 0 0 0 0 24 0 2 0 848 0 2082 0 D W V�! �G AMA= 13A�4ocs 1A-c1om 0.143 0.143 1270 se s s 4.00 4.00 35.56 2.55 2.55 34.77 0 0 0 0 0 0 0 0 0 0 0 0 34 32 0 34 32 0 136 128 0 86 81 0 G 13A-46ts 1A-c1om 0.143: 1270 W • w 4:00 35.66 2.55 5521 0 0 0 0 0 0 0' 0 0 0 0 0 0 0 0 0 .4A5-2om ..:0.770..w 21.56 19:31 0. 0 0 .0 0 0 0 0 P 12C-Osw 0.091 .- 2.55 128 0 0 0 0 0 0 0 0 C . •16A30mcl 0.032 _ ._ 0.90 2.32 45 45 40 104 204 204 182 .472 F 22Atol 0.989 27.69 0.00 45 5 138 0 204 34 946 0 6 cj AED excursion -16 -85 Envelo'peloss/gain 339 196 2978 3106 12 a)' Infiltration 87 24 593 162 b) Room ventilation 0 0 0 0 13 Internal gains. Occupants@ 230 0 0 1 230 Applianceslother 0 0 Subtotal (lines 6 to 13) 425 214 3571 3498 Lessekiemalload 0 0 0 0 Less transfer 0 0 0. 0 Redistribution 0 0 0 0 14 Subtotal 425 214 3571 3498 15 Ductloads 32% 49% 135 104 32% 49% 1131 1704 Total room load 560 318 1 1 4702 5203. Air required(cfm) 28 14 232 232 Calculations approved bvACCA to meet all requirements of Manual J 8th-Ed. wr�gHtsofC 2020-Jar,.081620.47 Right-Sute@ Uriversal 20l9 l..9.0.07 RSU08101 Page 3 igNsoftHVAC1THEGRAND CARLTON-1446-IMPACTrip Calc = W8. Front Door faces: N YF wrightwft`° Right-JO Worksheet Job: Entire House Bate: ey QUICK CALLS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name LAUNDRY GREAT/DINING 2 3 4 5 E)posedvuall Room height Room dimensions Room area 6.0 It 8D it heat/cool 7.0 x 6.0 It 42.0 IF 47.0 ft 9.8 ft heaUcool 1.0 x 526.0 It 526.0 IF Ty Construction number U-value (Bluh/LT) Or HTM Area or perimeter (ft) Load (B h) oorperimter (it) (Btuh) Heat Cool Gross NIPS Heat Cool Gross NIPS Heat Cool 6 13AAocs 4A5 tom' 13AAocs 0143 _0770 0.143 , n ` n a 4'.00 . 21:56: 4.00 2.55 19.31 2.65 0 ` 0 0 0 0 0 0 0 0 � 0 0' 0 . 255 38 0 217 0 0 860 ` 815:. 0 552 ' 730 0 11 11DO 13AAocs. 13AAocs 1A-c1om 1270 0.390 0.143 0.143 1270 a a se s s 35.56 10.92 4.00 4.00 35.56 8729 11.31 '2.55 2.55 34.77 0 0 0 48 0 0 0 0 48 0 0 0 0 192 0 0 0 0 122 0 0 0 0 0 0 0 0 . 0 0 0 0 0 01 0 0 0 0 0 0 0 t=1Aclom D :W : - 1LV�1 G' G IA-c 4A5 -tom:- 12C-Osw 16A30md 22A tpl 12 0 0.770 0.091 0.032 0.989 w' w - - - 35.56 21.56 2.55 0.90 27.69 5521 19.31 128 2.32 0.00 0 .0. 56 42 42 0 0 56 42 6 0 0 143 38 166 0 .0 72 97 0 20:. 41 0 526 526 160 p 41 0 526 47 661 0 880 0 471 1302 420 p -, :.788 0 1220 0 P C F 6 c) AED e=ursfon -22 668 Envelope losstgain 539 270 4997 4379 12 a) Infiltration 104 28 997 273 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants@ 230 0 0 2 460 ApplianoWother 0 0 Subtotal (lines 6 to 13) 643 298 5994. 5112 Less e4emal load 0 0 0 0 Lesstransler 0 0 0 0. Redistribution 0 0 0 0 14 Subtotal 643 298 5994 5112 15 Dud loads 32% 49% 204 145 32% 49% 1699 249D 1Total room load 846 443 7892 7602 Ajr required (drn) 1 42 201 1 390 338 Calculations approved WACCA to meet all requirements of Manual J 8th Ed. 4$6- wr79tit�'" 2020-Jan-081620:47 ACLP► Right -Suite@ Universal 201919.0.07 RSU08101 Page 4 igHsoftHVAC\THE GRAND CARLTON-1446-1MPACT.nip Calc=MJ8 FrordDoorfaces: N . - wrigti-tsoft° Right-M Worksheet Job: Entire House Date: QUICK CALLS, INC. By. 317 ST. LUCIE LN., Fr. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS AOL.COM 1 Room name FOYER M BATH 2 Exposed wall 7.0 ft 8.0 ft 3 Room height 8D It heaf/000l 8.0 It heakool 4 5 Room dimensions Room area. 1.0 x 50.0 ft 50.0 ffz 7.0 x 8D ft 56.0 flz Ty Constuclion U-value 'Or HTM Area (T) Load Area (fF) Load number (BWhfiF--: F) (Btuhd2) or perimeter M (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 yJ �C 13AAocs 0.143 n 4.00 2.55 .8 8 32 20 0 0 -0 a .4A5.2om : _ 13AAocs 0.770 0.143 n a 21.56 4.00 , - 19.31 2.55 0 48 0 27 0 108 .0 69 0 0 0 0 :0 0 0 0 11 1A-clom 11DO 1270 0.390 a a 35.56 10.92 8729 11.31 0 21 0 21 0 229 0 238 0 0 0 0 0 0 0 0 D -W t•-G 13AAocs 13AAocs 1A-clom 13A46cs hblom 0.143. 0.143 1270 0.143 1270 se s s , w w 4.00 4.00 35.56 4.06 35.56 2.55 2.55 34.77 2:55 55.21 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 64 7 0 0' 0 57 7 0 0 0 228 247 0. 0 0 145 241 0 0 G :4Arr2om 12C-Osry -16M. Omd .0.770 0.091 0.032 w - 21.56 2.55 0.90 19.31' 128 2.32 0. 72 50 0 72 50 0 183 45 0 92 116 0 0 56 0 0 56 0 0 50 0 0 P C . F 22A 1pI 0.989 27.69 0.00 50 7 194 0 56 8 222 .130 0 6 c) AED excursion -39 -38 Envelope low/gain 792 496 747 478 12 a) Infiltration 121 33 138 38 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants@ 230 0 0 0 0 Applianoes/other 1 0 0 Subtotal (lines 6 to 13) 913 529 885 516 Less wdemal load 0 0 0 0 Lesstranst'er 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 913 529 885 516 15 Dud loads 32% 49% 289 258 32% 49% 2801 251 Total room load 1202 787 1166 ' 768 Air required (dm) 59 35 58 34 Calculations approved WACCAto meet all requirements of Manual J 8th Ed. 2020-Jan•081620.47 .4 CA RigltSuteC� Uriversa12019 79.0.07 RSU08101 Page 5 ighlsoftWAMTHEGRAND CARLTON-1446-IMPACT.np Calc=MJ8 Front Door faces: N Job: + wrightsoft® Duct S' telrn Summary Job: Entire House By. QUICK CALCS; INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772466-6796. Email: QUICKCALCS@AOL.COM For. THE GRAND CARLTON IMPACT WYNNE DEVELOPMENT, FT. PIERCE, FL Externalstatic pressure Pressurelosses Availablestatic pressure Supply/ return available pressure Lowestfrictibn rate Actual airflow Total effective length (TEL) Heating 0:50 in H2O 0 in H2O 0.50 . in H2O 0.250 / 0.250 in H2O 0.285 in/100ft 1160 cfm 176 Supply Branch Detail Table Cooling 0.50 in H2O 0 in H2O 0.50 in H2O 0.250 / 0.250 in H2O 0.285 in/100ft 1160 cfm Name Design (Btuh) Htg (cfm) Clg (cfm) Design FR Diam (in) H x W (in) Duct Mat Actual Ln (ft) Ftg.Egv Ln (ft) Trunk BATH h 566 28 14 0.364 4.0 Ox 0 VIFx 22.4 115.0 st1 BEDROOM 2 h 4702 .232 232 0.360 7.0 Ox 0 VIFx 23.9 115.0 st1 BEDROOM -A h 3327 164 163. 0.300 6.0 Ox0 VIFx 31.8 135.0 st2 BEDROOM-B h 3327 164 163 0.285 6.0 Ox 0 VIFx 40.6 135.0 st2 FOYER h 1202 59 35 0.505 4.0 Ox 0 VIFx 4.0 95.0 GREAVDINING h 3946 195 169 . 0.300 7.0 Ox0 VIFx 31.8 135.0 st2 GREAWDINING-A h 3946 195 169 0.300 7.0 Ox 0 VIFx 31.8 135:0 st2 KrrCHEN c 3437 21 153 0.379 6.0 Ox 0 VIFx 17.0 115.0 st1 LAUNDRY h 846 42 20 0.361 4.0 Ox 0 VIFx 23.3 115.0 st1 M. BATH -A h 768 58 34 0 0 Ox 0 VIFx 0 0 WIC c 174 3 8 0.309 4.0 Ox0 VIFx 27.0 135.0 s2 Supply Trunk Detail Table Trunk Htg Clg Design. Veloc Diam H x W Duct . Name Type (CFm) (cfm) FR. (fpm) (in) (in) Material Trunk st2 PeakAVF 721 672 - 0.285 918 12.0 0 x 0 VinlFlx st1 st1 PeakAVF 1043 1091 0.285 1020 14.0 0 x 0 VinlFlx Wr%ghtsoft 2020-Jarr081620:48 AL- RigltSLite@)Uriversal20l9l9.0.07RSU08101 Pagel A=.JgttsoftWAC\THEGRAND CARLTON-1446-IMPACT.np Calc=W8 FrontDoorfaces: N Return Branch Detail Table Name . Grille Size (in) . Htg . (cfm) Clg (ch) . TEL .(ft). Design .. FR Veloc . (fpm) Diam (in) H x W (in) Stud/Joist . Opening (in) Duct Mati. Trunk rb1 Ox0 1160 1160 0 0 0 0 Ox 0 MFx -> wrightsoft® 2020-Jao-08162048 RigttSUte®Uriversal 201919.0.07 RSU08101. Page 2 ...igtboftWAMTHEGRAN DCARLTON-1446-IMPACT.rtp CaIc=W8 FrordDoortoes: N