HomeMy WebLinkAboutBuilding PlansGulf Coast Supply and MFG 5v Crimp Metal roofongPFL #11451.12
26 ga. 5v crimp metal roofing attached to plgwood deck using #9 x 1.5"
wood screws with self sealing washer at 12" o.c. max spacing over ASTM D
(type 2) 30 lb felt underlayment installed with min. 4 aide laps and 6" end
aps fastened with corrosion resistant tin caps and with I. " ring shank nails
spaced 6" o.c. at all laps and two staggered rows 12' o.c. field. Attach
deck to trusses using attachment detail on this sheet
5/8" thick light textured
stucco on typical concrete 12
block construction SLOPE 14
'•. 2„
o
3 COVERED
(DPORCH
W R ,--——————————— — — — —
-- -- — _,, � ;�, ---------
— 1
5/8" thick x 8"w cut
coral finished stucco bands Finish Columns with
5/8' thick cut coral
finished stucco bands
I G H T F., _� E V gee T I O N
SCALE: 1/4' = II
Gulf Coast Supply and MFG 5v Crimp Metal roofing PL #11651.12
26 ga. 5v crimp metal roofing attached to plywood deck using #9 x 1.5"
wood screws with self sealing washer at 12" o.c. max spacing over ASTM D
(type 2) 30 lb felt underlayment installed with min, f aide laps and V end
laps fastened with corrosion resistant tin caps and with 1.25" ring shank nails
spaced 6" o.c. at all laps and two staggered rows 12" o.c. in field. Attach
deck to trusses using attachment detail on this sheet
PE GRESS
i
5/8" thick light textured
stucco on typical concrete
block construction
"T,
Gulf Coast Supply and MFG 5v Crimp Metal roofing FL #11651.12
26 ge. 5v crimp metal roofing attached to plywood neck using #9 x 1.5"
wood screws with self sealing washer at 12' o.c, max spacing over ASTM D
(type 2) 30 lb felt underlayment installed with min. 4 side laps and 6" end
laps fastened with corrosion resistant tin caps and with 1.25" ring shank nails
spaced 6 o.c. at all Iapa and two staggered rows 12" o.c. in field. Attach
deck to trusses using attachment detail on this sheet
stucco on tgprcal concrete 5/8" thick x 8"w cut
block construction coral finished stucco bands
REAR ELEVATION
SCALE: 1/4' a 1'—O'
Gulf Coast Supply and MFG 5v Crimp Metal roofing FL #11651.12
26 ga. 5v crimp metal roofing attached to plywood 'deck using #9 x 1.5"
wood stress with self sealing washer at 12" c.c. max spacing over ASTM D
(type 2) 30 lb felt underlagment installed with min. 4 sidda laps and 6" and
laps fastened with corrosion resistant tin caps and with 1.25" ring shank nails
?aced L" o.c. at all laps and two staggered rows 12" o.c. in field. Attach
dpsick to trusses using attachment detail on this sheet
-1/8" Thick cut coral stucco over paper
backed wire lath nailed to substrate through
one layer of 15 lb felt using 8d nads. Substrate
to be 19/32' CDX Plgwood nailed at 0 o.c.
in field and edges with IOd ring shank galvanized
/ nails into truss webbing.
I�
it [OI
it
I
I[O71 �
IN
110
Mw 1 11
Sm
2" x 4" top plate 1I "1/2' drywall ceiling on truss bottom cord
I/2" drywall on
2" x 4" studs at 14" o.c.
base —board I I / 2" x 4" P.T. bottom plate
\ 4" concrete slab with fibermesh OR
VW #10/10 WWM on 6 mil Viaqueen over
clean compacted termite treated fill
Interior Non-Bearina Partition
rlf s,
SCALE: 1/4' - 1'-0'
0'-0' = Finished Floor €
ALL CONTRACTOR WARRANTIES BEGIN WHEN THE CLOSING
OCCURS BETWEEN THE BUYER AND WYNNE BUILDING CORP.
AND WILL CONTINUE FOR ONE YEAR FROM THAT DATE
PERMITTING INFORMATION (FORM 100)
Florida Building Code Residential: Lth Edition and ASCEI-10for Wind Loading
Buildin Deign is: Enclosed Risk Categol� II Wind Velocity: IL5 mph ultimate
Mean Roof Height: IIII'—Oo• Roof Pitch:
4:12
Or
internal Pressure ant: t01n
Subjectabdity to damage from: Weathering: Negligible Termites: Vera HeavuWidth
of Roof End Zone: 3'-4" Wind Speed:IL5mph ultimate
Wind Exposure Classification: C
LZI x O L= 0.�2L
Adjustment factor for Exposure Height: ASD desi n
Load Combination: ASCE 1-10 Section 2.4 DL+LL; DL+O.LWL; O.LDL+O.1,WL
Components t Cladding Wind Pressure (NET) Roof Zone: I. +20.6/-32.6 psf
Roof Zone: 2. +20.4/-51.0 pal
Roof Zone: 3. +20.L/-84.0 psf
Components t Cladding Wall End Zone Width: 3'-48
Components t Cladding Wind Pressure (NET) Wall Zone: 4.+35.8/-38.1 Pal
Rod Zone I
Wall Zone: 5. +35.8/-41.8 per
Walls Zone 4
Components t Cladding Wind Pressure (NET) on Garage Door:+32.0/-40.3ps1
Shear Walls Considered for Structure? Yes
Continuous Load Path Provided?
m Rod Zone 2
�
yy�� �
Walt Zane 5
ponen Are Comts an Cladding Detta s Provided? Yes
END ZONE
Minimum Sal Beenng Pressure: U29e. PresimpUve: X B Test: psi
S E ODUC AP ROYAL F RIM A T P O E TION F R O E IN S
� s Corner Zones
Rod Zone 3
ROOF LIVE LOAD: 31 fief ROOF DEAD LOAD: 10 Pat
FLOOR LIVE LOAD: _ff_ paf FLOOR DEAD LOAD: 10 sisif
JOB ADDRESS: "S
�;T; I..UPIE COUNT
ncc 10/9
FLOOR PLAN Recess top plate L'w x 3/8"d with coo top - vanfy typo p35'-O"
for steal support angle with contractor
CRASH POST DETAIL 8e detail on then sheet Is'-3° a'-1oY2" 1 " 8'-10 y,"
TYPICAL NOTES: SCALE I/4" = I'-O" 7'-7yz" rt'-7%2"
N.T.S.
I. Contractor to verify ALL notes and dimensions prior to 3C high by 4" diameter 2
proceeding with work. steel crash post. Floor Steel countertop support angle -
p g Flange with 4 - 3/8" Install 4' from each end end Base cabinet " ° 11.1. ° ° Lai °
2. Contractor to STRICTLY enforce ALL OSHA Requirements. expansion bolts into one in center of counter. ° °
3. ALL Lumber to be used as Beam Rafters etc... to have slab (3/8"t 50 ksi steel plate) see angle detail EGRESS 12' x 12" Concrete column
2" x 8" wood studs block filled with concrete and
a minimum 1,4
00 P.S.I. fiber stress. 6" 1/2' dr wall at IL" o.c. 13'-II" p (2) #'1 bars vert. tied into
4. No dissimilar metals to touch. y o lintel& above
5. ALL Concrete used for slabs shall be min. 2,500 PSI concrete. ��" 2%" 2' x e" PT wood plate ° o Filled cell under PORCH
ALL Concrete used for vertical filled cells, cost. tie beams etc.. to girder above
shall be 3,000 P.S.I. concrete and/or 4,000 P.S.I. grout mix ° WIRE LATH t STUCCO
6. Drywall at ceilings shall be leveled and attached to bottom chord =3/e' O KITCHEN ISLAND FRAMING DETAIL C19, EILING
of trusses with screws per FBC R102.3.5.
1. ALL wood in contact with concrete shall be pressure treated. 2�zi," 3'
8. ALL wall dimensions are nominal and not finished wall or stud dimensions.
9. ALL plumbing fixtures to be low flow.
10. Contractor to Provide Drain at water heater in accordance
with the current edition of the Florida Plumbing Code.
II. Contractor to Provide a 2'-8" wide door at one bathroom for
handicap accessibility requirements.
12. Lowest finished floor to be set bg Governing Building Department
surveyor to set in field.
13. Separation between residence and garage shall be per FBC R302.6 L"
14. Door between garage and residence shall be 1-3/4"t 20 min. rated door
w.H. = Water Heater
5. Wall and Ceiling shall have a flame -spread classification of not greater than 200 per FBC R302.9.1
6. Wall and ceiling finishes shall have a smoke -developed index of not greater than 450 per FBC R302.9.2
1. All exposed attic insulation materials installed on attic floors shall have a critical radiant
flux not less than 0.12 watt per square centimeter. Exposed foam plastic insulation
materials exposed on the underside of the roof deck or on the attic walls shall comply
with F.B.C. R316 - see permit info box of code edition
8. Gygppsum board material shall conform to ASTM C36, C19, C415, C514, C630, C931
Ccf60, C1002, C1041,0111, C1118, C1218 C1395, or C1396 and shall be installed
according to the following: (FBC R102.3.5�
Drywall
Thick,
Location
Orientation
Framing
Member
Mex s akin
M fasteners
Nod wizing options for
Spacing
installation drywall into
Maximum
Nails
Screws
ggot
2 ox framing s
n.
thickness
Ceiling
Perpendicular
24"
"I"
12"
13ga 1 3/8' long with III head
0.098' diameter x 1 1/4' long
„
y2
annular -ringed or 5d coder nail
0.080' dia. x 1 5/8' long with
Walls
Direction
14'
8"
1L'
15/64' headOR
Gppsum board nail 0.080 dia.
x 1 5/8" with 9/32' head.
Calling
Perpendicular
24"
T
12'
139a 1 5/8" long with 19/L4" head
OR
0.098' diameter x 1 3/8' long
annular -ringed or Ld coder nail
s
0.092' dia xR 1 1/8' long with
Wells
Either
IL"
g•
IL'
Direction
I/4* head
OR
Ggpsum board nail 0.0916' dia.
x I 1/8' with 19/L4' head.
19. ALL ceramic tile surfaces installed shall conform to ASTM A108.1 thru A108.6,
A108.1, A118.1, A118.3, A136.1 and AI31.1
20. Cement, fiber -cement or glass mat g psum backers in accordance with ASTM
C1288, C1325, OR C1118 and installed I.A.W. manufacturers recommendations shall
be used as backer for the wall tile in tub areas and wall panels in shower areas.
21. Insulation including facings such as retarders or vapor permeable members installed
within floor -ceding assemblies, roof -ceiling assemblies, wall, crawl spaces and attics
shall have a flame spread index not to exceed 25 with an accompanging smoke
developed index not to exceed 450 when tested in accordance with ,4STM E 84.
Insulation shall comply with F.B.C. R316.
Gulf Coast Supply and MFG 5v Crimp Metal roofing FL #11451.12
21. ga. 5v crimp metal roofing attached to plywood deck using #9 x 1.5'
wood' screws with self sealing washer at 12" o.c. max spacing over ASTM D
ftype 2) 30 lb felt underlayment installed with min. 4 side laps and V end
laps fastened with corrosion resistant tin caps and with 1.25' ring shank nails
spaced 6" o.c. at all laps and two staggered rows 12" o.c. in field. Attach
Cock to trusses using attachment detail on this sheet
i�.
I2 2'
MASTER IBATH
2. l�.
yi LAUNDRY
I I I 1
1 1 2"1
I I 1 vi
` go �• i
3" silrai "
3 woi 2" 2
Window Schedule
Mark
Size
Rou h Open.
Window Description
PRESSURE ZONE
1.
4'-5Ys"x 4'-1,'/a"
54i"x 54Ya"
single Hung
ZONE 4
2.
111 Ya"x 5'-3 %a"
15' x i %,"
Seigle Hung
ZONE 4
3.
2'-2* x V-2%"
21h"x 3858"
Single Hung
ZONE 4
4.
3'-1* x 5°-3%"
38' x L3'/4"
Single Hung
ZONE 4
ALL Windows to be aluminum windows w/ tint
and mullions per
elevations.
ALL windows to withstand
pressures in permit info box
on sheet I
ALL windows in bathrooms to be tempered
All rough opening dimensions to be verified by contractor
with manufacturer a specs
prior to construction
6.
Door Schedule
Mark
Size
Rough O e ing
Door Description
PRESSURE ZONE
A
9'-0' X 1'-0"
108' x 84'
Overhead Geroge Door
ZONE 4
B
V-0* X L'-Bx
416'/4" x
Fiberglass Panel - lm ing
ZONE 4
C
L'-OM X L'-so
14' x 81 'h" ,.
sliding Glows Doer
ZONE 4
D
2'-0' X V-8'
Solid Core - Wood
- I. -Panel -Bi-Fold
Pirrdted 24' x 81 %d'
9
2'-6' X L'-8'
Solid Care - Wood
- L-Panel
F
5'-0' X V-8'
Solid Core - Wood
- L-Panel - Bi-fold
G
2'-8* x L'-so x 1 N"
Said Core Wood. Steel, or Masorete Door
H
2'-8' X V-8"
Solid Care - Wood
- L-Penal
J
2'-6' X V-8'
Solid Care - Wood
- L-Panel - Br-Pold
ALL Exterior doors to withstand pressures stated
box on sheet #I
GARAGE DOOR SPECIFIED IN PRODUCT APPROVAL FORM
WITHSTAND THE PRESSURES STATED IN PERMIT INFO BOX
All rough opening dimensions to be verified by contractor
with manufacturer a specs prior to construction
in permit info
AND SHALL
ON SHEET #1
Simpson HETA 20 or equal
hurricane anchor et each truss 12 Masonry Beam
with (10) IOd x 11/2' nails I" x 6" P.T. Buck nailed to
f 24' ox.) eupporting Max. 4 I - PRE-ENGINEERED TRUSSES block with case hardened nails
18101be. uplift at 24 o.c. TYPICAL prior to door attachment
(shop drawings by manufacturer)
Aluminum Drip -�-0 R-30 blown fiberglass
Edge t Fascia in bottom chord of trusses
I/2" drywall with smooth finish
2" x V Sub -Fascia Two rows of beam block filled with concrete
and (l) #5 bar Cont. in each row. Substitute
Kagcan fug o vent vmul soffit installed precast lintel filled with concrete and (1) #5
mngg 1/8' dia shank x I.5" long lowly. bar cunt. for bottom row over openings
roofing nails with 3/8' dia. head per
product approval -see chart sheet #1 1/2" drywall over I" x furrin
stnppa at IL' o.c. with R4.1 Pirfod _
inaulation on tgpical 8" Block walls
5/8" thick light textured All drywall to be installed per FBC R102.3.1
stucco on typical concrete I and shall meet all pertaining ASTM codes.
block construction ro Mortar to be Type "M" onTg proportioned per FBC RL01.1 -
and Mortar lonta shall comply with PBC R601.2.1.
Provide Dur-O-Rock at all wet areas (ex. showers, tubs etc...)
#5 bar vert. w/
30' overlap Fill cell with concrete and
at each filled cell lU #5 bar vert. (typical).
ax spacing shall not exceed
Wood 48' unless otherwise noted
Base see foundation plan notes for
spacing at openings
4" concrete slab with fibermesh OR
VxV #10/10 WWM on L mil Visqueen over
clean compacted termite treated fill
Cr
Grade
e l _ 14" x 14" Concrete footing
with (2) #5 bars cunt. and #5
TYPiCAL SECTIONtransverse bars at 48" o.c.
Scale : 1/2" = 1'-0"
KITCHEN
r ,MV
e
12'
I
I
N
2' LLAV-1
1u2,
V BATH 82
SANITARY RISER
Attach buck to block mall with
1/4' dia. Elmo cone screw* with mn.
1 1/4' penetration at 12' o.c. max
and 4' mix from each corner thru
two
2' x L" PT Buck
Exurwr
no
YIM
a8 Wood screws thru jamb into back
Detail
at each hinge and 15' *1 max and
at Door pear to dam' attaahmont
NTS
INSTALL VULKEM BLOCK SEALANT
T
ON ALL JAMB, HEADER, AND
SILL
BLOCK PRIOR TO BUCK
INSTALLATION
i
Instal windows thru buck into
block with 3/I0 tap -can with
1 1/2' penetration at i' o.c. max
from a&+ corner and 20.' &a. mex
thereafter at .Iemba and 20" o.c. max
Exterior face
at head and oil per product approval
or mall
gunk to be r x 4' PT
Vanes
I'x4' P.T. Buck nailed to
Detail
lock with came hardened nails
at Windows prior to window attachment
NTS
IT
3"� r
Verify attachment
hole location with GC
Install SGD thru buck into prior to fabrication
block with 3/16" tap -con with 3/8" thick
1 1/2" penetration at 0o.e. max steel bracket
'_'"'from each corner and 20." o.c. max
thereafter at head per product approval
3"
Use 3/16" tap -con with COUNTER TOP BRACKET DETAIL
1 1/2" penetration at 6" o.c. max.
from each corner and 20" o.c. max
thereafter at sill per product approval
1' x 6' P.T. Buck nailed to
block with case hardened nails
Head prior to door attachment
fixed door
sliding door
IY Masonry Wall -.
^Bottom' Trac Typical Flooring
Bill Install SGD thru buck into
block with 3/IL" tap -con with
S l l d i n g D o o r Detail 1 1/2" penetration at 6" o.c. max
from each corner and 20." o.c. max
area at at Jambs per product approval Jamb
At Masonry Wall NTS
Braden i Braden AIA, PA
Architects - Planners
411
S.E. Coconut Avenue
Tel
: (112) 281-8258
Fax
: (112) 281-8283
E-marl:
bradenaiaOcomcast.net
CLt.im,.t 1=1
'AAQQ1 #tAA/%nn^r
z
I
MASTER
BEDROOM
8'-O" A_F.F.
Flat Ceiling I
I
® I
Rod t Shelf 8'-O" to19'-8" A.F.F.
T Vaulted Ceding
in
ao �� GREAT'ROOM
N
�LOS T I o I
sc
_
Rod E Shelf = n
I
to be
high
C-4"
III
DRYER ASHER I
In
LAUNDRY I
to 9'-8" A.F.F.
d Vaulted Ceiling
I
\34 ),,1#hNING V=omlt t 11 I ROOMI counter Lops t. 13/8' thick steel
overhang wall 15" I counter top supp is
t,l
SECOND
q BEDROOM
e'-O" A.F.F. O
Flat Ceiling
t1
12'-e"
11,
THIRD,
BEDROOM
FM
top& to
1 wall 1.5"
-�
-�--� aw
C110
_JI
+41" high wall
I
1 ow I
o a
I I
I
KITCHEN -
I
I
rlib8'-O"
to 19'-e" A.F.F.__ iI
Vault d Ceding M O
Upper cabinets to
-
extend over Ref.
I
MICRO
RlF'. NON-V INT
l
I
l
OPENING L
-
-
2'
Provide auto
%� R-1 Batu Inwukeieii `r
V
w'H'
closer
4"� Steel Ballard
©
Sae detail on this
sheet
ul
OFla
>
r
2tx xA`aass ,
I
zI
A
` am `ght
J
I
k --�
- -
rillIQ
s 8'-O" A.F.F.
IRV Flat Ceiling
GARAG
I4
0
°
MT °
garage to be
2 _e
struck block r+
°
EMERGENCY
EGRESS
i_____________
___
�
I
1
1
1
1
r
I
1
1
I
o
t
t
I
I
I
I
N
Die 6
c i
uD co in
ZL r
Nb
z
H.B.
O
a-
N
A
2'-8" ® 9'_0„ 2, 8., 6 _4„ 2,_8. 9'-0,. ® 2' 8" REVIEWED FOR
-I- J145CODE COMPLIANCE
ST. LUCIE COUNTY
Square Footage Breakdown SOCC
Total A/C Space = 1,153 sq. ft.
Covered Porch Total = 212 sq. ft.
Garage = 459 sq. ft.
Total Cubic Ft = 14,024 Under Roof Total = 2,484 sq. ft.
W gnne Building Corp. Date Drawn : Revisions : Sheet Comm #
j REAR Drawn
5-23-18 Garage floor slope and
T H E w I I�I � D S O R PORCH Drawn log: smoke detector revision 21
15- I
c.c.u.
Spanish Lakes RIGHT Checked bg: Impact
Si. Lucie County Florida D.R.B. 01= 5
1 rN, U lr I U r\ /-,\ L_ I Y L/ I I_ -
I. ALL FOOTING ARE DESIGNED FOR A MiNIMUM OF 2,500 PSF SOIL
BEARING CAPACITY. IF ANY SUB -SOIL, MUCK OR NON -UNIFORM
CONDITIONS EXIST, REPORT TO ARCHITECT AND OBTAIN
PROPER ENGINEERING DATA FOR DESIGN.
2• ALL SLABS AND FOOTINGS TO BE A MINIMUM 2,600 PSI AT 28 DAYS
ALL COLUMNS, FILLED CELLS, AND BEAMS SHALL BE MIN. 3000 PSI
BE 3000 PSI OR 4.000 PSI GROUT MIX AT 28 DAYS
3. POISON SOIL AND COVER W/ 6 MIL. VISQUEEN WITHIN 24 HOURS. NO
SOIL POISONING TO BE ACCOMPLISHED OUTSIDE OF FOUNDATION.
4 GROUND FLOOR SLAB TO BE A MINIMUM 4" THICK W/ 6X6 10/10
WELDED WIRE MESH REINFORCING ON 6 MIL. POLYETHYLENE VAPOR
BARRIER ON TERMITE TREATED, CLEAN MACHINE COMPACTED FILL
(MINIMUM 95% DENSITY). LAP POLYETHYLENE 12" MINIMUM. FIBERMESH
MIX MAY BE SUBSTITUTED FOR WELDED WIRE MESH.
5 LOT TO BE CLEARED OF ALL SMALL PLANT GROWTH AND DEBRIS
BEFORE FILL IS BROUGHT IN. FILL MATERIAL SHALL CONSIST OF
CLEAN GRANULAR SAND CONTAINING LESS THAN 10% MATERIAL
PASSING THE US STANDARD NO. 200 MESH SIEVE. PLACE
STRUCTURAL PILL IN LOOSE LAYERS OF 12" IN THICKNESS AND
COMPACT EACH LIFT TO AT LEAST 95% OF ITS MODIFIED DRY
PROCTOR VALUE.
6• GENERAL CONTRACTOR TO VERIFY ALL EXISTING CONDITIONS AND
DIMENSIONS. BRING ANY DISCREPANCIES OR OMISSIONS TO THE
ATTENTION OF THE ARCHITECT.
7. GARAGE FLOORS TO BE SMOOTH TROWEL FINISH (SLOPPED PER
FOUNDATION PLAN). PROVIDE 1-1/2" RECESS FOR OVERHEAD DOOR
FOUNDATiON FLAN
8. SLOPE ALL PORCH SLABS, COVERED WALK, ETC. AWAY
FROM HOUSE TO DRAINS (IF PROVIDED) PER PLANS
9. DESIGN LOADS ARE AS FOLLOWS:
ROOF (DL+LL) = 41 PSF
WIND VELOCITY = PER PERMIT INFO BOX ON SHEET #1
EXPOSURE =" C"
10. ALL REINFORCING STEEL SHALL BE GRADE 40, MEETING ASTM A-16, E
A-35 SPECIFICATIONS. ALL ANCHOR TO BE A - 30-1 STEEL.
11. ALL DOWELS, SLEEVES, CONDUITS, INSERTS, BLOCKOUTS, ANCHOR
BOLTS AND FRAMES SHALL BE IN PLACE PRIOR TO POURING CONCRETE.
FOR OPENINGS AND SPECIAL FEATURES OMITTED ON THESE PLANS,
SEE ARCHITECTURAL OR MECHANICAL PLANS WHERE APPLICABLE.
12. MINIMUM CONCRETE PROTECTION FOR REINFORCING BARS:
FOOTING: 3"
BEAMS: 1-1/2"
13. LAP ALL REINFORCING STEEL A MINIMUM OF 48 BAR DIAMETERS.
14. USE STRUCTURAL GRADE WOOD WITH A MINIMUM Fb OF 1400 PSI
IS. ALL STANDARD LUMBER SHALL BE SYP WITH A MINIMUM Fib OF 1000
PSI OF NO.2 SOUTHERN PINE, UNLESS NOTED OTHERWISE.
14. ALL LUMBER IN CONTACT WITH ANY CONCRETE OR MASONRY SHALL BE
PRESSURE TREATED. FASTENERS TO HAVE MIN. G185 RATING.
I. Any changes to plans must be submitted to the architect
for approval before proceedingWith construction.
2. Contractor Shall be responsible for verification of all
notation and dimensions before starting construction.
3. Soil conditions assumed to be 2500 psf. Should any other conditions be
encountered, the architect shall be notified in writing for revision
-4. Verify all recess thickness at showers, tile, etc....
5. Contractor to provide filled cell with concrete and 1 1*5 bar vert. at 48"
O.C. max. Provide (1) filled cell on each side of openings upp to 5'-II" wide.
Provide (2) filled cells on each side of openings from 6'-O" to 9'-11"
and Provide (3) filled cells on each Side of openings from 10'-0" and up
Contractor to see plans for any other condition used. Foundation walls
shall have filled cells at 24" o.c. unless otherwise noted (see section)
6. Contractor to provide for Form Board Survey - Form Board Survey
to be provided to Truss Company prior to truss construction
1. Contractor to provide for soil test prior to construction and provide
a copy of soil test to architect for review prior to construction
8. ALL Reinforcing steel shall be grade 60, meeting ASTM A-16 and
A-35 specifications. ALL Anchors to be A-301 steel.
9. Provide a minimum of 3" concrete protection at footings and
1-1/2" concrete protection at beams for ALL reinforcing bars.
#5 bar Vert. w/ Thicken edge to 8"x8"
SCALE: 1/4" = I'—O"
FOOTING
SCHEDULE
Mark
Sme
Description
I
14"W
x 14"D
MONOLITHIC FOOTING
WITH
2 #5 BARS CONTINUOUS
12"W
X 14"D
MONOLITHIC FOOTING
- V
STEP DETAIL ON THIS SHEET
30"
x 30" x IVD
COLUMN FOOTING WITH (4)
#5 BARS EACH WAY
B'W
x 8"D
THICKEN SLAB EDGE
WITH
1 #5 BAR CONTINUOUS
®x
With
With
14"D
Curb at Garage
MONOLITHIC FOOTING
WITH
2 #5 BARS CONTINUOUS - CURB • 0'-0'
6
12"W
X 18"D
MONOLITHIC FOOTING
- V
STEP DETAIL ON THIS SHEET
30" overlap S ECT ONS AL with concrete and 4" concrete slab with fibermesh OR
at each filled cell one #5 bar continuous Vx6" #10/10 WWM on 10 mil Visqueen over
\ clean compacted termite treated fill
4" concrete slab with fibermesh OR
L"xb" #10/10 WWM on 10 mil Visqueen over
clean compacted termite treated fill
ti �1110111 � �
TYPICAL FOOTIN
14"w x 14"d concrete monolithic
footing with (2) #5 bars cost.
ETAIL
4" concrete slab with fibermesh OR
611x6" #10/10 WWM on 10 mil Visqueen over
clean compacted termite treated fill
s #5 bar cont.
��
#5 bar Vert. w/
30' overlap
at each filled cell
Adjust curb height
based on gar. floor
slope.
#5 bar in curb \
-
,. ,
tr tra;0
101, (2) #5 bars cunt. bottom steel
12"
2 DETAIL AT 6" GARAGE STEPDOWN
SCALE 1/2" = I'-O"
12' x 12' concrete column
block filled with concrete
and (2) #1 bars vert. tied
into lintels above
Top of footer
IL" below finished floor
Verify house slab
height in field
III x
30"x30"AV concrete
_1 column footing with (4)
#5 bars each way
SCALE 1/2" = If
mlwi i! "- ■min
SCALE 1/2" = 1'-0"
4' concrete slab with fibermesh OR
VxV #10/10 WWM on 10 mil Visqueen over
clean compacted termite treated fill
0'-01,
(III I I 14"w x 14"d concrete monolithic
footing with (2) #5 bars cont.
14"
ARAGE CURB
J SCALE 1/2" = it.
4" concrete slab with fibermesh OR
611x6" #10/10 WWM on 10 mil Visqueen over
clean compacted termite treated fill
i #5 bar cont.
101, (2) #5 bars cont. bottom steel
1r'
DETAIL AT 9" GARAGE STEPDOWN
SCALE 1/2" = 1'-0"
Termite Protection for New
Construction.
Soil treatment used for subterranean termite prevention
inside the foundation perimeter shall be done after all
excavation, backfilling and compaction is complete.
If soil area is disturbed after initial chemical soil treatment
area shall be re -treated with a chemical soil treatment
including spaces boxed or framed.
Treatment must be in accordance with the rules and laws
established by the Florida Department of Agriculture and
consumer services.
Protective sleeves around metallic piping penetrating
concrete slab on grade floors shall not be of cellulose
containing materials and shall receive application of
termicide in annular space between sleeve and pipe.
2" x L" PT wood secured with \
3/8"dia. x V anchor bolt at IS" o.c.
overhead door track secured to wood
jamb per manufacturer's product approval
Garage Door Jamb Detail
GARAGE DOOR TO WITHSTAND PRESSURES STATED NTS
PERMIT INFO BOX ON SHEET #I. SEE PRODUCT
APPROVAL FORM FOR MANUFACTURER MAKE AND MODEL.
Filled Cell Masonry Column With One
4+5 From Footing To Beam Each. Filled Cell Masonry Column With One
Conc. Fill To Be 3000 PSI #5 From Footing
See Floor Plan For Location g To Tie Beam
Conc. Fill To Be 3000 PSI
See Floor Plan For Location
.
Double Filled Cell Column Single Filled Cell Column
NTS NTS
r— — — — — —�
12' x 12" concrete column block filled
with concrete and (2) #1 bars vert. tied
Into lintels above
1Y,
8'-102" I °
lo'-off
— — `a
I I I I I ° ° ° o p ° o
----�----- i
® L— J®
® ©Lit
I FII
2,q
2j
Filled cell under
girder above
I©I J
r
Rear Porch Slab to O
be poured separatelu
p
ju ® I
ryl
°
from House Slab. O
0-
Thicken footing to
I 24"w x 14"d x 24"L I
k
I
under filled cell
��j I under girder bearing. I ° °
�Q
FI J4
°I
I
I
I
°I
°
H.B.
A/C
Rea Patio/Slab to FI
be flush with bottom of
1
sliding door recess.
Slope I"
I
��yyI
LJ'
I
I
I
I
I
4" concrete slab with fibermesh OR I
I 6"x6" #10/10 WWM on 6 mil Visqueen over
clean compacted termite treated fill
I� I
I I
oYER ASHER I
IQ
I I
I I
I I
I F-a
°
i-
F-
I I �-
I
° I
I I
°I I°
r I
OW I I
I ,
FI \1 4" concrete slab with fibermesh OR
L"xL" (CI0/10 WWM on 6 mil Visqueen over
clean compacted termite treated fill I
MICROWAVE
i
I sr c�lAR °
OPENING • O
I
i 4'$ Steel Ballard °
i I See detail on this sheet
I F`#>1 1
I I IF 11
I Q I i o F5 I
L — ca q////,
F6------ r — — —
—
a ° I I
° r — — — — — — — i ° ° I a"
LU
I O 14 step
LU
I Io
-4 I F517
°L---------4J*—----- — ° ° ° 1.5" Recess for O — — a ° ° ° 1.5" Recess for O 00
arage Door ;a arage oor
9'-0" 2'-a 6'-4" 2'-8. 91-01, 2,-S"
Braden t Braden AIAe PA
Architects - Planners
Wynne Building Corp.
Tell S.E. Coconut Avenue
f j�l D C�
THE
FB Tel : ('i12) 281-8258
W IC
I `� v 4
S ankh LakesE-marl:
St. Lucie Count Florida
Fax : (112) 281-8283
bradenaia comcast.net
Stuart. FL 34996 #AACOO0032
0
m
Date Drawn Revisions :
REAR 3-28-18 �-23-18 Garage floor slope and
Drawn bg: smoke detector revision
PORCH C.C.U.
RIGHT Checked bg:
D.R.B.
H.B.
REVIEWED K
CODE COMPLIANCE
ST. LUCIE COU'
SOGC
Sheet Comm #
31 15-159B
impact
OF 5
ROOF SHEETING
ATTACHMENT DETAIL
I. Minimum Nall Size = 8d ring shank (min. 2.5" long)
2. Minimum Screw Size = #8 x 2"
3. Minimum Sheathing Thickness 19/32" CDX Plywood
4. Use nails or screws bas d on pressure for roof stated
in permit info box on these pans for zone 3
II
Area
Ede
Field
Fastener
x.
Pressu
Zone I
611
4 of8d
ring shank
45 psf
Zone 2
4 "
4 of
8d ring shank
lG psf
Zone 3
4 to
11 If8d
ring shank
84 pat
I*
* Zone 3a
6"
6"
#8 wood screw
112.5 psf
** Use nails or s rews based on pres ure for roof stated
in permit info box on these plans ?or zone 3
Verify with Plan
Concrete
/ Lintel
Provide #5 bars with min. 48 bar
diameters overlap into beam. Tie
filled call steel into continuous
beam block steel. X,,
Provide #5 bar set in pre -cast ROOF FL A i • Scale : 1/2" = 1'-0"
lintel into beam where length of
the opening calls for it. — O v e r h a in t 1' - O" l t h t d t h fi t
Provide Cast -Crete =
8U8-OB/OT precast - `-
lintel act in mortar -4
Min. Be Bearing-i--� -�- - --
"x 12"
rin Block
#�
-i Rebar
Reber 48 Bar Die.
Min. Overlap
Column to Lintel AttdChment
ovide PT Buck
;ached per ,lamb
ads into filled ce
4" Pre -cast
SIN X
— Roof
gs a
pitch at
Un ass o erwlse no a On Is s ee
-f:12 unless otherwise noted on this sheet
— Truss
shop drawings
to be
provided by manufacturer
— Any
changes
to this plan
shall be submitted to the
Z architect for
approval in
writing prior to starting construction.
- ALL
TRUSS
TO TRUSS
CONNECTIONS BY
�I
TRUSS MANUFACTURER
- Architect to review Truss Shop Drawings Prior
t t t f 1 t d Ift f t
O cons I uc ion or ayoU an up I veil
ice Ion
Filled Cell — Contractor to provide
for Form Board
Survey
and to provide
Form Board Survey to
Truss Company
prior to
truss construction
bars with min. 48 bar
srlep in filled cell. Tie
ral'into continuous
yl I Concrete Footing
(we factor schedule
for exact sizes)
DETAIL AT WINDOW OPENING iN
CBS WALL Scale: 1/2" = 1'-0"
SINGLE PLY REAR GIRDER TRUSS,
Had 20 x 44 bledurm to vart. We of
tress with II x LS role at 40 o c.
Install Siapaan MOT eito way wins
5/8' die. threaded rod set wni. IZ'
into wet base and (22) 10d rails me truce
TRUSS BLOCKING DETAIL
AT GIRDER STRAPPING:
AT CENTER BEARING POINT
NTS I I
I/8" thick II ht textured stucco installed per
AST" C III over ASTM D type 2 pa er backed
BEAM
` . wire lath Walled to substrate through one layer of
r/�� Irl ASTM D Tgpe 2 felt paper using Sid nails. Substrate
to be 19/32" CDX Plywood nailed at L" o.c. in field
and edges with IOd ring shank nails into studs.
Mark Size and Descri Lion
Gulf Coast Supply and MFG 5v Crimp Metal roofing FL #II451.12
Two rows of beam block rIIIRd with concrete and 1 #5 bar 2G ga. 5v crimp metal roofing attached to plywood -deck using #9 x 1.5"
BI continuous in each row. Hook vert. bar over top bar with wood screws with self sealing washer at 12" o.c. max spacing over ASTM D
#5 90e bend bar with a 10' min. lap at top bar. laps fastened Iwithelcorrosion resistantttine caps and with 1.26'lariingashank nails
spaced 6" o.c. at all late and two eta gored rows 12' o.c. in field. Attach
deck to trusses using atachmant data on this sheet
Additional recast Lintel n " u $$
#5 bare = Lintel Bar Clear A B
"_Fr. ,;: �IeAm Length Length Span Bars Bars
2'-10" 2'-8" I'-6" 2 u3 none
3'-6" 3'-4" 2'-2" 2.43 none
er8-OBAT 8!'8-115/IT O'8-I8/2T
Additional 4'-O" 3'-10" 2'-8" 2,43 none
- i #5 bars
ci.aA Mtn'; 1*IH4"
4'-C4'-4" 3'-2" 2,#3 none
ne Rau of:.:y Block Abov5'-4" 5'-2" 4'-0" 2,43 none
.-101,'"'"2u4 none
Precast L'•:: i '„Additions-6"6'-4" 5'-4 2,#4 none
#5 bars----r
7'-O" 6'-2" 2,45 none
2,#5 none
NOTES:
I. min. coverage of stee1=1.5"
2. min. bearing required a ea. end=8" ALL reinforcing steel Is grade 40.
3. standard for remf. stael=ASTM A615
TYPICAL LINTEL SECTION
( PRECAST CONCRETE )
LINTEL SCHEDULE
Mark
1111 do or
Unit
width
Lintel
Size
Cast -Crete
8
'H�
Block
Above
Bottae
still
Tap
steal
Sma
"I
Loa
(PLFD
Max
oad
L
fPLF)
Max.
wd�
fPLF)
L22
2'-2'
3'-d'
01128-OBAT
1
85
30L9
111114411
1024
L31
A',
4'-0'
�8-OB/IT
1
s5
2661
1363
143
L45
A 4'-5`
f V-10'
VIRe-OB/IT
A
1
$5
505
A'109
33"1
L50
6'-0'
B'—Is
Bfi8-O8/IT
1
86
1238
1 836
121
LAO
C-8'
T-V
81158-015/IT
I
s5
Ion
'121
534
L80
V-O'
Y-4'
BPS-IB/2T
I
s5
2
85
152
511
512
LI
1'-O"
11
1111138-10111
1
$5
2
s5
643
530
401
L905
11
11
e144-IB/2T
ONE
1
85
2
85
B33
se3
401
LI00
10'-0"
III
8f'8-IB/2T
1
85
2
86
592
4414
462
LIOOB
11'-44
8"6-I5/2T
ONE
1
85
2
86
is"
1028
452
L120
r10I�'�-/O�'
17-00
13'-4'
91138-18/2'r
1
s5
2
s5
411
428
324
L1208
17-00
13'-4'
8PI6-IB/2T
ONE
1
IB
2
85
1015
110
324
L140
W-00
IIIII
811116-IB/2T
ONE
1
85
2
85
1250
401
251
LILO
IL'-O'
n'-4'
111P8-IB/2T
1
85
2
85
Soo
112
N4
LILOB
IL'-O'
IT-4` 1
81"16-I15/2T
ONE
1
85
2
85
150
BOO
114
- ALL LINTELS SHALL BE MADE BY CAST-CRETE.
- LINTELS SHALL BE FILLED SOLID WITH 3000 PSI CONCRETE
- REFER TO CAST-CRETE CATALOG FOR ALL INFORMATION REGARDING
LINTEL CONSTRUCTION, HANDLING INFORMATION, AND SAFE LOAD REQ.
REQUIREMENTS
- LINTELS OVER III LONG ARE TO BE PRESTRESSED.
Simpson HETA 20 or equal
hurricane anchor at each truss
with (10) IOd x 1 i/2" nails -
( 24' o.c.) supporting Max
IIIuplift
Aluminum Drip .�--^^"'—"
Edge t fascia
12"
2" x L" Sub-Fasci
Kagcan fall o vent vinyl soffit installed
wing 1/8' dia shank x 1.5' long gals.
roofing nails with 3/8' dia, head per
product approval — we chart sheet #1
12' x 12' concrete column
block filled with concrete
and (2) #1 bars vert. tie
into lintels above
thicken edge to SAW
with concrete and
one #5 bar continuous
BEYOND
0oP footer
below finished floor
41 12
Aluminum Drip -
Edge t Fascia
Flash and Counter
flash
Nail ledger to
gable end to
with (2) IOd
at each web
Brace Gable and
with 2' x 4" SYP #2
aft back nailed to bottom
or top chords using (2) IOc
nails at each truss
PRE-ENGINEERED WOOD TRUSSES
e 24"o.c. TYPICAL
( shop drawings by manufacturer )
N
Q
W
a
m
�
r_
a-7
X
s7
.r
O W
IN
F-
9L
LU
2..c
ei ro
N
Q
U
°
aul
W
u
N
4
�G
\R-30 blown fiberglass
1/2' this stucco an 3/6' hi —rib lath
in bottom chord oP trusses
attached to horiraital ar-d vertrcal good
freeing with nods or staples to provide
1/2" drywall with smooth finish
no less then 1-3/4' penetretion iniA
Ares vital good framing and 3/4' penetration
Two rows of beam block filled with concrete
into vertreaI wood framing members
and (1) #5 bar cost. in each row. Substitute
precast lintel filled with concrete and (l) #5
bar cunt. for bottom row over openings
5/8thick II fit textured
1/2' drggwall over Is x furring"
9
strips at IL" o.c. with RAI trial
stucco on typical concrete
rnsulation
on tgpical
8" Block walls
block construction
All drywall to
be installed per FBC Rio2.3.1
Varies - see plan
Varies
and shall meet all pertaining ASTM codes.
#5 bar vert. w/
io
Mortar to be Type "M" onlpg
proportioned per FBC RbOTI
30" overlap
ProvidetDur joints shall
all
wetf area owers,
at
exx.Lh tubs etc...)
at each filled cell
Fill cell with concrete and
Rear Petro/Slab to
(l) #5 bar vert. (typical).
be flush with bottom or
ex spacing shall not exceed
sliding door recess.
Wood
48" unless otherwise noted
see foundation plan notes for
Base
spacing at openings
Step per foundation plan
4" concrete slab with fibermesh OR
L"xL" #10/10 WWM on L mil Visqueen over
Slope per foundation plan a
if
clean compacted termite treated fill
a
IIII IIII IIII 'li
IIII .L.- �l IIII ', . .III IIII IIII—IIII= III!
1III —III --II 1= 1111 IIII III -
IT — II
• FI
Tublcal Section at Front Forth
Scale . 1/2" = 1'-0"
Braden t Braden AIAe PA
Architects - Planners
411 S.E. Coconut Avenue
Tel : (712) 287-8258
Fax : (112) 281-8283
E-mail: bradenaia®comcast.net
Simpson HETA 20
5trap truss to wall using Simpson MGT wit
hurricane anchor 8t each
truss
5/a dia.
into beam
threaded rod with min 12 embed
either wet set or in epoxy with
( 24" O.C.) supporting
1810 lbs. uplift
Max.
HETA 20
(22) 10d
�truaa leg
nails into truss. Add blocking to
per detail on this sheet
IPA
Pr
IV r
IN
Own
11
WA IN
VA I HE W;-A-
I
O
t
PAWAIWA0A MrWYA Ar
I
I
iAttic
Access BI
110
l
11
i11
i
1
1
INI
=i�
THETA 2
Provide dawn t Simpson HETA 20 Pr7mde for putter
apO11 hurricane anchor at each truss
( 24" o.c.) supporting Max.
1810 lbs. uplift
WynrLe Building Corp.
THE WINDSC
S anis�h Lakes
S A. Lucie County Florida
QHETA 20D
0
I
N
a
w
N
W
REVIEWED FOR
\OODE COMPLIANCE
ST. LUCIE COUNTY
Provide downspout9O(',C
Date Drawn Revisions : Sheet Comm #
REAR 3-28-18 5-23-18 Garage floor slope and
Drawn bg: smoke detector revision
PORCH C.C.U. 4. 16-169B
RiGHT Checked bg: impact
D.R.B. 111 c
-2-19
I Opt. PATIO/SLAB
■
PANEL
"A"
Pal"
BR
Lead
Wee
Description
c"'d
c"'
DOW Moon
Wire
Lead
BR
1I
1
20
1.2 ke
812
Rerrgerator
I
ROW
#i
12.0 ka
50
2
1
20
1.2 ks
$12
Cloth" Washer
3
1
20
1.5 km
912
Kitchen S.A.C.
5
L
Dryer
810
5.0 ks
30
2
1
20
1.5 Its
#12
Kitchen S.A.C.
I
e
1
20
—
#12
Bothroae Recapta
9
10
Air Candamw
#10
5.0 ko
30
2
1
20
1.2 ks
812
olwoswwr
11
12
1
20
1.2 ke
$12
Microwave
13
1 14
1 As Hand
#10
5.0 ke
30
2
1
15
—
#14
General Lighting
15
It.
1
15
—
$14
General Lighting
11
18
WH
#10
5.0 ko
26
2
1
16
—
#14
General Lighting
19
20
I
I6
—
014
General Lighting
21
22
GDO
#12
0.e1 KIM
20
1
1
15
—
#14
General Lighting
23
24
Spare
Spare
25
26
Spare
Spam
21
1 28
1 Spare
Spam
1 29
1 Sol
Spero
PANEL "A" LOAD CALCULATION SHEET
Load Description
Ot .
I Watts
Total(Watts)
Genaral,Lightma t3, watts sg: ft,),,,,,,,,,,,,,,,,,,,,,,,,
,Small, Appliance, Cireuit(s)
,liangq... ............................. ......... .........
12efr(gerator..................................................
Mlcrawave.....................................................
Dish , Washer
...........................
�lothea .41.a>}her...............................................
.Clothed..PiI................................................
,Water Heater ..............
Garage,Door,Opener, ,, „
1135
3
SaIII
2
1,500
3,000
1
12,000
12.000
1
1,200
I 00
I
1500
11500
1
1,200
100
1
1,200
100
1
5,000
5,000
I
4 500
4,1500
I
No
810
Total Watts
35 IF
First 10000 Watts e100%
1
10,000
10,000
Remainder 29AI5 e40%
1
O
10,246
Electric Heat or A/C 10,000 065%
I
10,000
10,000
Calculated Load
Watts
30,246
Voltage
240
Calculated Wattage Divided bg Voltage = Total Amps 126.02
Panel Size Required = ISO Amps
Electrical S mbol Legend
S
Single Pole batch
®
Recessed Can Light
Double Palo Switch
Eyeball Recessed
FIB
Push Button Switch
Exhaust Fan
Dupiex Outlet
¢
Calling Mounted Light
Special Receptacle
♦
Wall Mounted Light
aterpr ground fault circlet
Light with Pull Chain )attic)
13
Floor Duplex Outlet
Computer Connecuon Jack
®
Carbon Monoxde Detector
4&
Flood Light
T
Thermostat
®
Electrical Panel
®
Central Vac
8
Electrical Meter
®
Smoke Detector
Ceding fan
®
Television Jack
Telephone Jack
a �
A/C Disconnect
®
I x 4 Fkirsiment Light
CM
12 x 4 Florescent Li
®
Speaker Hook -Up
= JUNCTION BOX TO SUPPORT A PAN
Q as THERMOSTAT LOCATION
B/A = BALANCED AIR
Vent thru
Soffit --
MECHANICAL LAYOUT
SCALE: 1/4" = 1'-0"
1-2-19
FIELD VERIFY SERVICE LOCATION RESPECIVE TO PANEL LOCATION AND USE APPROPRIATE RISER BELOW
A/C disc.
A/C disc.
#2/0 AL SER Cable
(3) #1 THHN Copper
S
With #1 Grnd
2" PVC Schedule
40 conduit
2" PVC Schedule
AMP
40 conduit sleeve A
MCB
into attic MCB
PANEL AHU
PANEL AHU
200a rated
200a rated
meter can n
meter can n
AiC
124 CFM
IO)dOxk
MASTER"
BEDROOM
12W2WO
124 CFM B/A
IOidOxL - e%
-J 141 CFM
IOx1OxI
id:1iPd
B/A
8x4x4
9 CFM
LOSET
8x4x4
50 CFM —
DRYER ASHER
LAUNDRY
L8x4x4
It CFM _
8x4x4
III CFM
12"xl
SECOND
BEDROOM
B/A
THIRD
BEDROOM
100 CFM
IOxLxL
METER METER 150 Amp
Intersystem bonding Intersptem banding Panel
2" PVC ( FPL Termnabon pant 2" PVC ( FPL Tsrminabon pant
schedule 80 schedule 80 r_________
GGARAGE
O��LF CART
2' rigid service FPL 2' rigid service FPL I G A R A G E
I
I
GEC Bar #`` e a ire GEC Bar #`` e a ira I
to ) 8'—i�Cria1'vanLad to �) 8'—�Crialivanaed I
ground rods ground rode
I
PORCH
14'1 CFM
IOx1OxI
EATi ROOM
I
I
I
I
I
I 14-1Clem
12'
DINING
ROOM
I
I I
o I DW
ELECTRICAL RISER ALTERNATE SERVICE ELECT. RISER
— Contractor shall use AL—CU Landing lugs. NTS — Contractor shall use AL—CU Landing lugs. NTS
Contractor shall torque lugs I.A.W.
manufacturers recommendations which
shall be verified prior to construction
Verify AIC/KIC Rating prior to ordering equipment
L
ELECTRIC NOTES:
— Contractor shall torque lugs I.A.W.
manufacturers recommendations which
shall be verified prior to construction
— Verify AIC/KIC Rating prior to ordering equipment
I.
Use copper wire only from panel to devices
15. Contractor shall guarantee all materials and workmanship
free defects for less than two from
20. All equipment and panel sizes shall be verified before
2.
Provide and wire all required smoke E Carbon
of a period of not years
ordering. The contractor &hall provide circuit routings to
Monoxide detectors.
the date of acceptance or certificate of occupancy, or one
suit the conditions.
3.
Contractor to verify location of electrical
year from closing sale of house.
,lob
service and provider.
Correction of defects shall be completed without additional
21. Furnish and install all fixtures as called for on the plans
4.
ALL bath and kitchen receptacles to be GFCI protected.
charge and shall include replacement& or repair of any
or as selected bg others.
S.
ALL exterior outlets to be WP/GFCI protected.
other phase of installation that may have been damaged.
L.
Recessed cans to be installed per NFPA requirements.
IL. It is not the intent of these plans to show every minor detail
22• All raceway& and pipes placed in or through any concrete
1.
Tamper reaistant AFCt receptacles are required in
of construction. The contractor shall furnish and install
slab &hall be spaced a minimum of three diameters of the
ALL rooms_
all items for a complete electrical system and provide all
largest conduit or pipe from any other service.
S.
A/C Return Air Balance Must comply w/ FBC RM1402
the requirements necessary for the equipment to be placed in
9.
A(C R Fri t�� lines that are run thru slabs must be
sleeve in
proper working order.
23. All exposed wire below 9'-1' shall be installed in metal EMT
Il. All work shall be done in accordance with the N.E.C. and conduit.
10. ALL A/C Equipment shall comply with energy calculation shall comply with all local codes and ordinances, and shall 24. Dryer Vents to be installed per
II. All work shall be performed by a licensed electrical meet all standard requirements of the local electric utility FSC RMI502
contractor, the completed Wtem shall be fully operative. and telephone company.
12. Contractor shall pay for all face, permits, tee ing, and
inspections including blower testing where required. 18. The electrical system shall be completely and effective1
13. All work shall be coordinated with other trades to avoid grounded as required by the latest edition of the N.E.C.
interference with the progress of construction.
14. All required insurance shall be provided for protection 19. All material shall be new and shall bear underwriters'
against the pubbc dablhty and property damage Por the labels where applicable.
duration oP the work -
3 TON
SEE MANUAL
'J' and Enargy
Calculation
for Unit lea,
Install oulet
under disc, —
not shown for
clarity
GARAGE
r----------------- i
I I
1 I
I 1
1 I
I I
I I
I I
I I
I I
I I
I I
AiC
MASTER
BEDROOM
;FC CLOSE
PORCH
WP GFCI ` 1
e �
�S
c
DRYER I AIC 5MERI
LAUNDRY
T �T
SECOND /
BEDROOM,/ I
/ 1
GREAT
ROOM
:..
ROOM
FCl
IF I
d�
_ _ 1
B E D R O O I IM , — — '�
Am
4"m Steel Ballard
See detail on this ahNt
F"I>I
r'�
/
O
I =
4,
S' -T -A xA5awes
1 �
L—"d—�"_J
7
OPTIONAL PANEL
LOCATION
_
\\
/
GARAGE
FCI
/ / 1
GFCI
150 Amp
(
`Z*L\
Panel GFCI \
r-------- _ �-�
y� i
{Y/}+
\ ` GFCI
r---------------i
Garage �'
Door I va
I
/
Garage
I Door
Opener I a
/
I Opener I
GOLF CART;
/
GARAGE
I I
1 I
I I GFCI
to galrage lights
i I
r
�
ELECTRICAL FLAN '-------
Past Light with O
SCALE: 1/4" = I'-O" Photo cell
Center Post Light
Attic Ventina Calculations
Total Attic Space = 2101 sq. ft. C 2309
Venting Ratio 1/150 = 18.00 sq. ft. required
Provide A Continuous Vented Soffit
between driveways
Wire For
Front Post
Light
REVIEWED FOR
CODE COMPLIANCE
ST. LUCIE COUNTY
ROCC
Braden i Braden AAA, Pro
Wynne Building Corp.
Date Drawn :
Revisions :
Sheet
Comm #
Architects - Planners
REAR
3-28-18
5-23-I8 Garage floor slope and
411 S.E. Coconut Avenue
J� III I j''�
THE w I I `� D S O R
PORCH
Drawn bg:
smoke detector revision
E— 1
IFD-159B
Tel : (112) 281-8258
RB
C.C.U.
Sppan1>�h Lakes
Fax : (112) 281-8283
E-mail: bradenalaScomcast.net
RIGHT
Checked by:
Impact
Stuart FL 99L #AAC0000 2
S. Lucie County Florida
D.R.B.
OF 5