TRUSSES FOR THE FIRST MUDEL H UL_D , BE SHIPPED AND SUCCESSFULLY SET BEFORE AN1 MORE TRUSSES ARE BUILT FOR T- AT MODEL.
ARRANJE WITH CRAN E OPERATOR IN ADVANCE FOR A SPREADER BAR OF 18' - 24 IN LENGTH
® DO not `tend On trusses U til they are bmCed per BCSI & properly nailed t0 straps & hangers -- I
15'-3" — - 19'-9"
•
DON'T LIFT TRUSSES
WITH SPANS LONGER THAN
30' BY THE PEAK.
CONSULT BCSI
30' Spanor less 30' to 60' $pan A
60 degrees
Spree er Bar
ior less
�_— '12 ag f— Approx 2/3 to _�
.I Tag rifle ,spon approx. Line 7/2 of Span
REFER TO BCSI REFER TO BCSI'
Truss must be set this way if crone used Truss most be set this way if crane used.
} Tvss s an exampls your truss moy not match. This is on example; truss may not match.
Insist crane operator sets truss this way. .insist crone operator sets truss this way.
TRUSSES FOR THE FIRST MUDEL H UL_D , BE SHIPPED AND SUCCESSFULLY SET BEFORE AN1 MORE TRUSSES ARE BUILT FOR T- AT MODEL.
ARRANJE WITH CRAN E OPERATOR IN ADVANCE FOR A SPREADER BAR OF 18' - 24 IN LENGTH
® DO not `tend On trusses U til they are bmCed per BCSI & properly nailed t0 straps & hangers -- I
15'-3" — - 19'-9"
•
DON'T LIFT TRUSSES
WITH SPANS LONGER THAN
30' BY THE PEAK.
CONSULT BCSI
30' Spanor less 30' to 60' $pan A
60 degrees
Spree er Bar
ior less
�_— '12 ag f— Approx 2/3 to _�
.I Tag rifle ,spon approx. Line 7/2 of Span
REFER TO BCSI REFER TO BCSI'
Truss must be set this way if crone used Truss most be set this way if crane used.
} Tvss s an exampls your truss moy not match. This is on example; truss may not match.
Insist crane operator sets truss this way. .insist crone operator sets truss this way.
I
I f s
SEAT PLATES BY CHAMBERS
4.00 F 12
8'
00
I I
1'
uP set=1/4" heel=315/16"
II
PLUMB CUT END
2 x 4 Top Chord
WALL HEIGHT 8'
TYPICAL END DETAIL
12
4.00 �-
2 2.00—
Cl)
W upset=1/4" heel=3 15/16" INDICATES LOAD BEARING
F PLUMB CUT END REQUIRED BY TRUSSES
2 x 4 Top Chord SUPPLIED BY BUILDER
AT A HEIGHT OF V-0"
WALL HEIGHT 8' ABOVE FINISHED FLOOR
END DETAIL: TYPICAL VAULT
�®I
I®I®I�I�I®I811■1�14�1�1�1�1�1®I®I®
iV/ //I/i
/�i/
��
///i/1
i '
/
Y/
��
I�i /,I
/
�
'/ /1
///,1r
it/
1/
1.�/ ,Iri
\ 1
�
�II
�II
1
I
II
1 1
I
I
010100.0
—
vim
0ea
lid
100aaaa
1%
'MIA
e__1�_
!lam
P'
®EllP
�01
_ _
sell
L
Pill "M
OAF
--
INVERTED11501
r...• •e,a •.
'1
�1
_®AMP
�1
My
:..-10y�=�Nl
� �I�I®I®I®ICI®I�li�l
■I®IB�I�I®I®I®I®I®I©►
I
I 14'-4" I
PORI(
H RIGHT
R
_T T
FABRICATION AGREEMENT
TRUSSES CANNOT BE STARTED UNTIL THIS AGREEMENT IS SIGNED & RETURNED
The legal description of the property where the trusses will be Irate led is:
The undersigned acknowledges and agrees:
I;Trusses will be made In strictaccordance with this truss placement diagram layout,
which Is the sole authority for detennlning.successful fabrication of the trusses.
2. All dimensions In this layout have been verllfed by the undersigned.
.3• Unless written splice Is provided by certmed mall to Chambers Truss within tart (10)
days of delivery the undersigned agrees that no be'* argee will be allowed..ln the event
such wrden notice Is fumished Chambers Trues shell have three i3) builiIness days In which
to begln repairs required, or to substitute olhec Wssea, at Chambers option.
4. 'The
undereigned acknowledges receipt of "BCSI 1-03" cannery sheet by'rPl & WTCA,
5. Delivery Is to Job site, It la the buyel's'responslblllty to make the Job site suitable for
delNery. Chambers Truss has the sole authority to determine the sultablllty of the Job site or a
portion of the Job site for delivery• Chambers Truss will be responsible for dump delNery only.
The buyer la responsible for additional dellvery expenses If Chambers Truss has to redeliver
bemuse job she Is riot prepared for delivery
or buyer is not prepared for delivery of trusses,
Buyer Is responsible to Chambers Truac for towing costs due to site conditions.
5. Price as shown In paragraph 7 below Is aubjeq to change If any changes are, made In
this. layout A $50 per hour fee for revisions may be charged by Chambers Truss. .
7: This Is a PURCHASE ORDER to Chambers, Truss of the sum agreed to, or V ne;
agreement a reasonable Pride. Invoice will be made on delivery and paid within terms of net
on dellvery. Involve may, be made at scheduled date of. delivery If buyer cannot acoepi
delNery of fabricated Wssea. The undersigned agrees to pay Chambers. Truss reasonable
shomey's fee for collections In event of payment not timely made. 1-12 %per month servJce
charge will be added for all sums not paid within terms,
. S. Signature or Initials anyw
here on this sheet
constitutes agreement to all terms herein.
Q:In consideration of Chambers Truss extending credit for this material the undersigned
uneondigonally guarantees payment when due of any and all Indebtedness owed to
Chambers Trues by any entity receiving material and the undersigned agrees to pay such
Indebtedness Including altomeys fees, If default In payment for materiel be made by the
recipient.
1.
10. In the event of any litigation concerning this agreement, the Items furnished hereunder
or payments referred to herein, the. parties agree that the stale venue for any such action will
be Saint Eilcle County, Florida.
11. Design responsibligles era per-Nedonst Standard And Recommended Guldellnes On
RasponslbllItes For Construction Using Metal Plate Connected Wood Trusses
ANSVrPVWTCA 4-2002"
DATED '�•'�
,SIGNED
FOR TITLE -"
Aspmaderbarmaybaregt Wiper"BC311-0U topleverttidtvy&damage.
Multiple ply trusses must be fastened togithar per engineering
Ciefore they are set, (allure to do so can result.ln roof collapse.
Temporary and permanent bracing are required and can save life
and property and Is the resp_nslbllity of the truss erector.
Study the contents ct the [nformatlon packet Included on delivery
before setting trusses.
Trusses must be setand braced perdeslgn to prevontinjuryEt dani
Trusses must be set plumb and square
Do notset bunks or stack of plywood, roofing materlal or any
"Other concentrated loads on trusses, this can cause collapse.
DO NOT SET TRUSSES USING THIS LAYOUT
USE LAYOUT DELIVERED WITH TRUSSES TO SET TRUSSES
CHAMBERS TRUSS INC
3105 Oleander Avenue
Fort Plerl Florida 34982-6423
r 800-551-5932
Fort Pierce 77 =4�51 ¢bRBt" or c rc Fax 772-466$711
Vero Beach 772.568 rawi � r,V3.86-3302 '
The °uble the k.approve, . --- ntative•s
ar
forchetra' shelf
&kre" contractor
otherconrs Field n1e earn responsihfe
revile 0 over, he
structure In +
strapp n of ro shape d
°M aravif 9, anp�y°adfn
fhefr rasp Y and If It to 9 on
Approved iva locations. atls and
Date: BY
Brade n 8 Braden ..,�...
A`
92.0/93.2 MITEK 4.2
"a• e.A.
DESIGN CRITERIA
County
SAINT LUCIE
Building Department
ST LUCIE COUNTY
Wind Design Criteria
ASCE 7-2010
cg
Wind Design Method
MWFRS/C-C hybrid Wind ASCE 7-10
I
Roofing Material
Shingle or Shake
;,
c;rp
Loading in PSF
Roof R.D.L.
ea
Top Chord Live
20
(
0 I
Top Chord Dead
7 4.2
0 �
Bottom Chord Live
10 Non -Concurrent
o
c
Bottom Chord Dead
10 3
r�l
^� I
TOTAL Load
37 7.2
w
M
o
Duration Factor
1.25
0
Wind Speed
165mph
N
m
Top Chord C.B.
Sheeting by builder.
Bottom Chord C.B.
Sheeting by builder.
Highest Mean Height
15'1"
Building Type
ENCLOSED
Building Category
II:Non Restrictive
Exposure Category
C
Barrier Island
No
Conforms to FBC 2017
R.D.L.=Restraining Dead Load C.B.=Continuous Bracina
Verify DESIGN CRITERIA shown above with the
building department and your engineer. '
Design Criteria is the responsibility of the
®-•-••"•••� ✓`.+w,•vt allwyl L114111GG1 VI r[CWtu.
Chambers Truss Inc. Drawing Name: M11392
Scale:- 1 /4 1'
82 to
tal trusses, 15 different trusses.
MI 4: RLC ACAD: RLC Reviewed By:
Date:10/07/15 Revised:03/21/18
1a' a 6• • 14•� RE�VIEWEI FOR Revised: 3/05/2020
_. i._. "
- C.ODE COMI WYNNE BUILDING CORP,
�/ /SP�GI�ALDCONCERN &MUST BE `► PAREAS ARE OFORCFi
�T. L.U�QC �'_� DESCRIPTION:
`� LEFT WINDSOR
� CHECKED CAREFULLY &MAY � J�
t INDICATE DEVIATION FROM � PAGE1of1CUSTOMERINITIALSEACHPAGE
LANs 15 TRUSS DRAWINGS ARE ATTACHED TO LAYOUT M 11392
6 507 sv` G,� S
®I®I®I®I®INO
�I�I�Iax
�I■II�II®ICI®I®I®ICI®I®�
PISMO
1
�
I
1
1
�
�
1
1
♦ r
1 �
11
11`
INN
\�
—\
�`y�ilssr`II�►�+i �vr'•�srs�l`�►'��Is♦ssr�
�®
_
ON1
SIR
VMS, 611MENIMMI11
ON
1631.
WIN ,
1%SENSE
®®101
1
IN
1111111,�_�_
I
Ilan
Es,.
\�
—\
1®
• • e
t..• •••C.
\—
SETBACK BOSTON
B
\
PlEI®
\
II
\
t
`0I1\\®\\\iI\■iI`��\\II\�,��`lIa®\\\`II�`�\\`II
\�\\\
\\\`�\\\`
®�`IIIC\AEII®\\\\
I\®\\\II`®\\\\II`■
I\®\\`II
I®I
MiTek�
RE: M11392 MiTek USA, Inc.
THE WINDSOR 6904 Parke East Blvd.
Tampa, FL 33610-4115
Site Information:
Customer: Wynne Dev Corp Project Name: M11392
Lot/Block: - Model: THE WINDSOR
Address: unknown Subdivision:
City: St. Lucie County State: FL
General Truss Engineering Criteria & Design Loads (individual Truss Design Drawings Show Special
Loading Conditions):
Design Code: FBC2017/TP12014
Design Program: MiTek 20/20 8.1
Wind Code: ASCE 7-10
Wind Speed: 165 mph
Roof Load: 37.0 psf
Floor Load: N/A psf
This package includes 15 individual, dated
Truss Design Drawings and 0 Additional Drawings.
With my seal affixed to this
sheet, I hereby
certify that I am the Truss Design Engineer and this index sheet
conforms to 61 G15-31.003,
section 5 of the Florida Board
of Professional Engineers Rules.
No. Seal#
Truss Name
Date
1 T19781803
A
9/23/2020
2 T19781804
Al
9/23/2020
3 T19781805
A2
9/23/2020
4 T19781806
A3
9/23/2020
5 T19781807
A4
9/23/2020
6 T19781808
7 T19781809
A5
ATA
9/23/2020
9/23/2020
`PY
FILE CU
8 T19781810
B
9/23/2020
9 T19781811
BHA
9/23/2020
10 T19781812
GRA
9/23/2020
11 T19781813
J1
9/23/2020
REVIEWED FOR
13 T19781815
J5
9/23/2020
14 T19781816
J7
9/23/2020
E
'CODE COMPLIANCE'
!YA �✓
15 T19781817
KJ7
9/23/2020
ST. LUCIE COUNTY
SO=
This item has been electronically signed and sealed by Albani, Thomas using a Digital Signature.
Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies
The truss drawing(s) referenced above have been prepared by
MiTek USA, Inc under my direct supervision ,``tttttti
based on the parameters provided by Chambers Truss. ��OoPS ATruss
Engineers Name: Albani, Thomas
My licenseDnrenewal date for the state of Florida. is February 28, 2021. :�����'���'�
Florida COA: 6634 No 39380
IMPORTANT NOTE: The seal on these truss component designs is a certification
that the engineer named is licensed in the jurisdictions) identified and that the
designs comply with ANSI/TPI 1. These designs are based upon parameters
shown (e.g., loads, supports, dimensions, shapes and design codes), which were
given to MiTek. Any project specific information included is for MiTek
customers file reference purpose only, and was not taken into account in the preparation of
these designs. MiTek has not independently verified the applicability of the design
parameters or the designs for any particular building. Before use, the building designer
should verify applicability of design parameters and properly incorporate these designs
into the overall building design per ANSI/TPI 1, Chapter 2.
STATE OF : 44/�
�llllll{It
Thomas A. Albani PE No.39380
MiTek USA. Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610 September 23, 2020
1 of 1 Albani, Thomas
Job
Truss
Truss Type
Qty
Ply
T19781803
M11392
A
HIP
1
1
�THEWINDSOR
Job Reference o tional
L,namoers truss, inc., run rierce, rt . ^•�• ,s�
ID:_kfiGCA6bx7j2Syl HDXFw7ye3KX-KTRK2jb7uXlhmgejamLw33G2phzq_UFBTsBBV6zXjH_
�1-0-0 6 10-14 9-0-0 14-11-0 20-2-13 26-0-0 , 28 1-2 35-0-0
-0-0 B-10-14 2-1-2 5-11-0 5-3-13 5-9-3 ' 2-1-2 ' 6-10-14
4x8 2x3 11
4.00 12
2x3 4 26 5
3x6 = 4x4 = 4x8 = 20
6 7 27 8 9
Scale=1:60.5
io w
3x4 — 3x4 = 3x6 — 6x8 = 3x4 = 3x6 — 3x4 3x5 —
26-0-0
LOADING (psf)
TCLL 20.0
TCDL 7.0
BCLL 0.0
BCDL 10.0
SPACING- 2-0-0
Plate Grip DOL 1.25
Lumber DOL 1.25
Rep Stress Incr YES
Code FBC2017/TPI2014
CSI.
TC 0.57
BC 0.47
WB 0.94
Matrix -MS
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
in (loc) Udefl Ud
0.42 12-23 >572 240
0.37 12-23 >659 180
0.03 10 n/a n/a
PLATES GRIP
MT20 244/190
Weight: 161 Ib FT = 20%
LUMBER-
BRACING -
TOP CHORD 2x4 SP M 30
TOP CHORD
Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD 2x4 SP M 30
BOT CHORD
Rigid ceiling directly applied or 4-5-1 oc bracing.
WEBS 2x4 SP No.3
REACTIONS. (size) 2=0-8-0, 15=0-8-0, 10=0-8-0
Max Horz 2=-97(LC 10)
Max Uplift 2=-235(LC 12), 15=-1439(LC 12), 10=-799(LC 12)
Max Grav 2=467(LC 17), 15=1596(LC 1), 10=685(LC 22)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-639/108, 3-4=-396/0, 4-5=-967/776, 5-7=-967/776, 7-8=454/938,
8-9=-1009/1884,
9-10=-1265/2154
BOT CHORD 2-17=0/652, 15-17=0/430, 14-15=-704/454, 12-14=-15861938, 10-12=-1971/1174
WEBS 3-17=-372/461, 4-17=-272/451, 4-1 5=-1 087/1002, 5-15=-336/386, 7-14=-766/399,
8-14=-580/997, 8-12=-958/447, 9-12=-358/600, 7-15=-1329/2190
NOTES -
I) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=70ft; L=35ft; eave=5ft; Cat.
11; Exp C; Encl., GCpl=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-6-0, Interior(1) 2-6-0 to 9-0-0, Exterior(2) 9-0-0 to
13-11-6, Interior(1) 13-11-6 to 26-0-0, Exterior(2) 26-0-0 to 30-11-6, Interior(1) 30-11-6 to 36-0-0 zone; porch right exposed;C-C for
This item has been
members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
electronically Signed and
4) This truss has been designed fora 10.0 psf bottom chord live load nonconcurrent with any other live loads.
Sealed by Albani, Thomas, PE
5) ` This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
using a Digital Signature.
will fit between the bottom chord and any other members.
Printed copies of this
P
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 235 lb uplift at joint 2, 1439 lb uplift at
joint 15 and 799 lb uplift at joint 10.
document are not Considered
signed and sealed and the
signature must be verified
on any electronic copies.
Thomas A. Alban! PE No.39380
MiTek USA, Inc. FL Cart 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
March 24,2020
® WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 5119/2020 BEFORE USE.
Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and propedy incorporate this design Into the overall Val
building design. Bracing indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek♦
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITPH Quality Criteria, DSB.89 and BCS/ Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610
Job
Truss
Truss Type
Oty,
Ply
THE WINDSOR
T19781804
M11392
Al
SPECIAL
1
1
Job Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL 8.240 s Mar 9 2020 MiTek Industries, Inc. Tue Mar 2412:54:08 2020 Page 1
ID:_kfiGCA6bx7j2Syl HDXFw7ye3KX-of?iF3blfgtYOgDv7Us9cGoCh5CAjz5KjVwkOZZXjGz
�1-0-0 8-6-0 11-0-0 14-9-0 19-8-14 24-0-0 27-4-7 35-0-0 $6-0-q
1100.0 8-6-0 2-6-0 3-9-0 4-11-14 4-3-2 3 4-7 7-7-9 0-0
5x6 = 2x3 II
4.00 12 4 21 5
�1
0
3x6 =
13 12
3x5 = 5x8 MT18HS =
3x4 =
6 22
2.00 12
5x8 MT18HS =
Scale = 1:61.3
3x12 =
10-0-0
14-9-0
24-6-8
35-0-0
10-0-0
4-9-0
9-9-8
' 10-5-8
Plate Offsets (X Y)—
[2:0-0-2 Edge] [7:0-4-0 0-2-3], [9:0-1-15 Edge]
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL.
in (loc) I/defi L/d
PLATES
GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.63
Vert(LL)
0.75 11-12 >563 240
MT20
244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.91
Vert(CT) -1.21
11-12 >348 180
MT18HS
244/190
BCLL 0.0 '
Rep Stress Incr YES
WB 0.77
Horz(CT)
0.35 9 n/a n/a
BCDL 10.0
Code FBC2017/TPI2014
Matrix -MS
Weight: 155 lb
FT = 20%
LUMBER-
BRACING -
TOP CHORD 2x4 SP M 30
TOP CHORD
Structural wood sheathing directly applied or 2-7-7 oc purlins.
BOT CHORD 2x4 SP M 30
BOT CHORD
Rigid ceiling directly applied or 2-2-0 oc bracing.
WEBS 2x4 SP No.3
REACTIONS. (size) 2=0-8-0, 9=0-8-0
Max Harz 2=-117(LC 10)
Max Uplift 2=-825(LC 12), 9=-825(LC 12)
Max Grav 2=1349(LC 1). 9=1349(LC 1)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-3209/2102, 3-4=-3006/2024, 4-5=-3022/2080, 5-6=-3022/2080, 6-7=-4643/2994,
7-8=-5324/3364, 8-9=-5751/3700
BOT CHORD 2-13=-1883/3007, 12-13=-1591/2657, 11-12=-2456/3908, 9-11=-3442/5478
WEBS 3-13=-425/410, 4-13=-354/571, 4-12=-362/617, 5-12=-269/279, 6-12=-1034/712,
6-11=-373/892, 7-11=-897/1523, 8-11=-404/435
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=70ft; L=35ft; eave=5ft; Cat.
11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-6-0, Interior(1) 2-6-0 to 36-0-0 zone;C-C for
members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) All plates are MT20 plates unless otherwise indicated.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
7) Bearing atjoint(s) 9 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify
capacity of bearing surface.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 825 lb uplift at joint 2 and 825 lb uplift'at
joint 9.
This item has been
electronically signed and
sealed by Albani, Thomas, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Thomas A. Albani PE No.39380
MiTek USA, Inc. FL Cent 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
March 24,2020
®WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE.��
Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and Is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall A
building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek*
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSLITP11 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610
Job
Truss
Truss Type
Qty
Ply
THE WINDSOR
T19781805
M11392
A2
SPECIAL
1
1
Job Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL 8.240 s Mar 9 2020 MiTek Industries, Inc. Tue Mar 2412:54:09 2020 Page 1
ID:kfiGCA6bx7j2Sy1HDXFw7ye3KX-HsZ4SPcOQ8?P?zo5hBO08ULMuVYnSPxUx9glY?zXjGy
1-0-0 8-6-0 13.0-0 14-9-0 224TO 27-4-7 35-0-0 Q6.0•q
-0-0 8-6-0 4-6-0 1-9-0 7-3-0 5-4-7 7-7-9
Scale = 1:61.3
4.00 12
5x6 = 3x4 =
5x8 =
I 21 D 22 6
N
n
3x6 =
12
3x4 = 5x8 =
2.00 12
3xl2
LOADING (psf)
TCLL 20.0
TCDL 7.0
BCLL 0.0
BCDL 10.0
SPACING- 2-0-0
Plate Grip DOL 1.25
Lumber DOL 1.25
Rep Stress Incr YES
Code FBC2017/TP12014
CSI.
TC 0.66
BC 0.95
WB 0.86
Matrix -MS
DEFL. in (loc) I/dell Ud
Vert(LL) 0.72 10 >585 240
Vert(CT) -0.94 10-19 >447 180
Horz(CT) 0.34 8 n/a n/a
PLATES
MT20
MT18HS
Weight: 160 lb
GRIP
244/190
244/190
FT = 20%
LUMBER- BRACING -
TOP CHORD 2x4 SP M 30 TOP CHORD
Structural wood sheathing directly applied or 2-6-15 oc purlins.
BOT CHORD 2x4 SP M 30 BOT CHORD
Rigid ceiling directly applied or 2-2-0 oc bracing.
WEBS 2x4 SP No.3
REACTIONS. (size) 2=0-8-0, 8=0-8-0
Max Horz 2=136(LC 11)
Max Uplift 2=-825(LC 12), 8=-825(LC 12)
Max Grav 2=1349(LC 1), 8=1349(LC 1)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-3211/2064, 3-4=-3017/1998, 4-5=-2580/1800, 5-6=-3379/2225, 6-7=-5242/3250,
7-8=-5759/3665
BOT CHORD 2-13=-1847/3008, 12-13=-1403/2418, 11-12=-1552/2629, 10-11=-1990/3441,
8-10=-3410/5485
WEBS 3-13=420/418, 4-13=-427/688, 4-12=-337/551, 5-12=-777/605, 5-11=465/925,
6-11=-391/277, 6-1 0=-1 318/2268, 7-10=-503/530
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=70ft; L=35ft; eave=5ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-6-0, Interior(1) 2-6-0 to 36-0-0 zone;C-C for
This item has been
members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
electronically signed and
4) All plates are MT20 plates unless otherwise indicated.
sealed by Albani, Thomas, PE
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
using a Digital Signature.
6) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
Printed copies Of this
will fit between the bottom chord and any other members.
7) Bearing at joint(s) 8 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verity
document are not considered
capacity of bearing surface.
signed and sealed and the
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 825 lb uplift at joint 2 and 825 lb uplift at
signature must be verified
joint 8.
on any electronic copies.
Thomas A. Albani PE No.39380
MiTek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
March 24,2020
®WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE 10II-7473 rev. 5/19/2020 BEFORE USE.
Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design Into the overall �
building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek•
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS11TP/1 Quality Criteria, DSX89 and SCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610
Job
Truss
Truss Type
City
Ply
THE WINDSOR
T19781806
M11392
A3
SPECIAL
1
1
Job Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL 8.240 s Mar 9 2020 MiTek Industries, Inc. Tue Mar 24 1Z:54:1U ZU2U rage 1
ID:_kfiGCA6bx7j2Syl HDXFw7ye3KX-127SgidOBS7Gd7N IFvvehhuYXvu2Bsnd9pPr4RzXjGx
1-0- 8-6-0 15 0-0 20-0-0 24-6-8 27-4-7 35-0-0 6-0
-0-0 8-6-0 6-6-0 5 0-0 4-6.8 2-9-15 7-7-9 0-0
Scale = 1:62.3
�i
0
3x5 =
4.00 12
14
2x3 11
5x6 =
13
5x6 =
4x5 =
2.00 12
3x12 zz
rn
0 - r
IA
6
8-6-0 16-3-0
15-3-0
4-6-8
r
10-5-8
Plate Offsets (X Y)—
[2:0-1-6 Edge] [3:0-3-0 Edge] [8:0-3-0 0-3-4] [9:0-1-15 Edgel
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL.
in (loc)
I/deft
L/d
PLATES
GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.60
Vert(LL)
0.73 11
>572
240
MT20
244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.95
Vert(CT)
-0.97 11-20
>432
180
MT18HS
244/190
BCLL 0.0
Rep Stress Incr YES
WB 0.83
Horz(CT)
0.36 9
n/a
n/a
BCDL 10.0
Code FBC2017/TP12014
Matrix -MS
Weight: 160 lb
FT = 20%
LUMBER-
BRACING -
TOP CHORD
2x4 SP M 30 TOP CHORD
Structural wood sheathing directly applied or 2-6-15 oc purlins.
BOT CHORD
2x4 SP M 30 BOT CHORD
Rigid ceiling directly applied or 2-2-0 oc bracing.
WEBS
2x4 SP No.3 WEBS
1 Row at midpt 7-12
REACTIONS.
(size) 2=0-8-0, 9=0-8-0
Max Horz 2=-155(LC 10)
Max Uplift 2=-825(LC 12), 9=-825(LC 12)
Max Gra , 2=1349(LC 1). 9=1349(LC 1)
FORCES. (lb)
-Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD
2-4=-3256/2031, 4-5=2426/1588, 5-6=-2680/1790, 6-7=-2829/1832, 7-8=-5320/3257,
8-9=-5720/3554
BOT CHORD
2-14=-1817/3048, 13-14=-1817/3048, 12-13=-1258/2274, 11-12=-2935/5103,
9-11=-3302/5445
WEBS
4-14=0/329, 4-13=-897/636, 5-12=-316/661, 6-12=-317/616, 7-12=-2727/1643,
7-11=-107211939, 8-11=-390/391
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=70ft; L=35ft; eave=5ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-6-0, Interior(1) 2-6-0 to 36-0-0 zone;C-C for
members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
This item has been
3) Provide adequate drainage to prevent water ponding.
electronically signed and
4) All plates are MT20 plates unless otherwise indicated.
sealed by Albanl, Thomas, PE
5) This truss has been designed fora 10.0 psf bottom chord live load nonconcurrent with any other live loads.
using a Digital Signature.
6) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
Printed Copies Of this
will fit between the bottom chord and any other members.
7) Bearing at joint(s) 9 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify
document are not considered
capacity of bearing surface.
signed and sealed and the
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 825 lb uplift at joint 2 and 825 lb uplift at
signature must be verified
joint 9.
on any electronic copies.
Thomas A. Albani PE No.39380
MiTek USA, Inc. FL Cart 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
March 24,2020
® WARNING -verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 511912020 BEFORE USE.
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an Individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and property Incorporate this design Into the overall
building design. Bracing Indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
MiTek'
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS11TP11 Quality Criteria, DSB-89 and BCSI Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601
Tampa, FL 36610
Job
Truss
Truss Type
Qty
Ply
THE WINDSOR
T19781807
M11392
A4
SPECIAL
1
1
Job Reference o tional
Chambers Truss, Inc., Fort Pierce, FL 8.24U s Mar 9 ZU2U MI I eK Inausmes, Inc. I ue Mar 24 12:b4:11 "LULU Page 1
ID:_kfiGCA6bx7j2Syl HDXFw7ye3KX-DEhgt5eexIF7FHyUpcQtEvQjTIDGwGhnOT90duzXjGw
1-0-0 8-6-0 14-9-0 17-0-0 18-0 24-6-8 27-4-7 35-0-0 6-0
0-0 8-6-0 6-3-0 2-3 0 0-0 6-6-8 2-9-15 7-7-9 0-0
Scale = 1:62.3
4.00 12 5x6 = 4x6 =
9.1
16 15 6x10 =
3x5 = 2x3 II 5x8 = 3x12
zz
2.00 12
8-6-0 14-9-0 180-0
24-6-8
_
35.0-0
8-6-0 6-3-0 MO
6-6-8
10-5-8
Plate Offsets (X Y)—
[2:0-1-6 Edge] [9:0-3-0 Edge] [11:0-1-15 Edge]
LOADING (psi)
SPACING- 2-0-0
CSI.
DEFL.
in
(loc) Udefi Ud
PLATES
GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.59
Vert(LL)
0.80
13 >528 240
MT20
244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.95
Vert(CT)
-1.05
13 >400 180
MT18HS
2441190
BCLL 0.0
Rep Stress Incr YES
WB 0.98
Horz(CT)
0.39
11 file n/a
BCDL 10.0
Code FBC2017frP12014
Matrix -MS
Weight: 172 lb
FT = 20%
LUMBER-
BRACING -
TOP CHORD 2x4 SP M 30
TOP CHORD
Structural wood sheathing directly applied or 2-6-14 oc purlins.
BOT CHORD 2x4 SP M 30
BOT CHORD
Rigid ceiling directly applied or 2-2-0 oc bracing.
WEBS 2x4 SP No.3
WEBS
1 Row at midpt 8-14
REACTIONS. (size) 2=0-8-0, 11=0-8-0
Max Horz 2=-175(LC 10)
Max Uplift 2=-825(LC 12), 11=-825(LC 12)
Max Grav 2=1349(LC 1), 11=1349(LC 1)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 260 (lb) or less except when shown.
TOP CHORD 2-3=-3253/1989, 3-5=-2435/1560, 5-6=-2399/1639, 6-7=2217/1501, 7-8=-2380/1519,
8-10=-5361/3228, 10-11=-5716/3480
BOT CHORD 2-16=-1776/3045, 15-16=-177613045, 14-15=-1117/2168, 13-14=-29M/5154,
11-13=-3232/5441
WEBS 3-16=0/334,3-15=-882/614, 5-15=-238/254, 7-14=-163/427,6-14=-309/604,
6-15=-315/409,8-14=-3146/1901,8-13=-1034/1946,10-13=-343/333
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=70ft; L=35ft; save=5ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-6-0, Interior(1) 2-6-0 to 36-0-0 zone;C-C for
This item has been
members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
electronically sighed and
4) All plates are MT20 plates unless otherwise indicated.
sealed by Albanl, Thomas, PE
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
using a Digital Signature.
6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
Printed Copies Of this
will fit between the bottom chord and any other members.
7) Bearing at joint(s) 11 considers parallel to grain value using ANSI/rPI 1 angle to grain formula. Building designer should verify
document are not considered
capacity of bearing surface.
signed and sealed and the
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 825 lb uplift at joint 2 and 825 lb uplift at
signature must be verified
joint 11.
on any electronic copies.
Thomas A. Albani PE No.39380
MTek USA, Inc. FL Cart 6634
6904 Parke East Blvd. Tampa FL 33810
Date:
March 24,2020
---
AWARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/1912020 BEFORE USE.
Design valid for use only with MTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing Indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
iwiTek'
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSVTPlf Quality Criteria, DSB•69 and BCSI Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601
Tampa, FL 36610
Job
Truss
Truss Type
City
Ply
THE WINDSOR
T19781808
M11392
A5
SPECIAL
16
1
Job Reference o tional
Chambers Truss, Inc., Fort Pierce, FL 8.240 s Mar 9 2020 MiTek Industries, Inc. Tue Mar 24 12:54:13 2U2U Page 1
ID:_kfiGCA6bx7j2Sy1 HDXFw7ye3KX-9dpbinfuTN VrUb6tw1 SLJKWOV6vFOEp3rneVhmzXjGu
1-0-0 8-64) 14-9-0 17-6-0 24-6-8 27 4 7 35-M 6-0
0.0 8 6-0 6.3.0 2-9-0 7-0-8 2-9-15 7-7-9 -0-0
�1
0
5x8 MT18HS 11
4.00 12
14 13
3x5 = 2x3 ll 5x10 =
2.00 12
Scale = 1:60.3
3x12
IT
I�
0
8-6-0 14-9-0
24-6-8
35-0-0
8-6-0 6-3-0
9-9-8
10-5-8
'
Plate Offsets (X Y)—
[2:0-1-6 Edge] [8:0-3-0 Edge] [10:0-1-15 Edge]
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL.
in (loc) I/deb Ud
PLATES
GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.81
Vert(LL)
0.80 12-13 >526 240
MT20
244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.92
Vert(CT) -1.28 12-13 >329 180
MT18HS
244/190
BCLL 0.0
Rep Stress Incr YES
WB 0.74
Horz(CT)
0.36 10 n/a n/a
BCDL 10.0
Code FBC2017frP12014
Matrix -MS
Weight: 160 lb
FT = 20%
LUMBER-
BRACING -
TOP CHORD 2x4 SP M 31 'Except`
TOP CHORD
Structural wood sheathing directly applied or 2-2-0 oc purlins.
1-4,8-11: 2x4 SP M 30
BOT CHORD
Rigid ceiling directly applied or 2-2-0 oc bracing.
BOT CHORD 2x4 SP M 30
WEBS
1 Row at midpt 6-12
WEBS 2x4 SP No.3 *Except*
6-12: 2x4 SP M 30
OTHERS 2x4 SP No.3
REACTIONS. (size) 2=0-8-0, 10=0-8-0
Max Horz 2=-179(LC 10)
Max Uplift 2=-825(LC 12), 10=-825(LC 12)
Max Gram 2=1349(LC 1), 10=1349(LC 1)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-3247/2112, 3-5=-2449/1679, 5-6=-2397/1763, 6-7=-5452/3624, 7-9=-5398/3482,
9-10=-5732/3689
BOT CHORD 2-14=-1865/3040,13-14=-1865/3040,12-13=-1223/2137,10-12=-3431/5459
WEBS 3-14=0/303, 3-13=-861/619, 5-13=-216/264, 6-13=-300/527, 6-12=-2247/3526,
7-12=-323/38B, 9-12=-321/306
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=70ft; L=35ft; eave=5ft; Cat.
This item has been
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-6-0, Interior(1) 2-6-0 to 17-6-0, Extedor(2) 17-6-0 to
electronically signed and
21-0-0, Interior(1) 21-0-0 to 36-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip
sealed by Albani, Thomas, PE
DOL=1.60
using a Digital Signature.
3) All plates are MT20 plates unless otherwise indicated.
Printed copies of this
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
document are not considered
will fit between the bottom chord and any other members, with BCDL = 10.Opsf.
Signed and Sealed and the
6) Bearing at joint(s) 10 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify
signature must be verified
capacity of bearing surface.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 825 lb uplift at joint 2 and 825 lb uplift at
on any electronic copies.
joint 10.
Thomas A. Albani PE No.39380
MiTek USA, Inc. FL Cart 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
March 24,2020
....... .... ............
_.-.-- - —------- ---- --- ---
® WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE 10II-7473 rev. 5/19/2020 BEFORE USE.
Design valid for use only with Mparameters
iTek® connectors. This design is based only upon pameters shown, and Is for an Individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing Indicated is to prevent buckling of individual truss web andlor chord members only. Additional temporary and permanent bracing MiTek•
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI?PI1 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610
Job
Truss
Truss Type
Oty
Ply
THE WINDSOR
T19781809
M11392
ATA
COMMON
5
1
Job Reference o lional '
chambers I russ, Inc., Tort Tierce, t-L
i1
6
12-11-0
mz,iv s mar v zuzu ml I eK Inausin s, Inc. i ue mar L'1 7L:a9: 19 cucu
ID _kfiGCA6bx7j2Sy1 HDXFw7ye3KX-dpMzW7gWEgdi61g3UkzarX2EkWJA7jTD4RN3I
4.00 12 45 =
6
4-7-0
8-4-0
Scale = 1:59.5
17 '- 15 "" "' 14 '- 12
3x6 — 2x3 II 4x6 = 3x8 = 2x3 II 3x6 =
3x8 = 46 =
j N
I�
0
8-4-0 12-11-0
22-1-0
35-0-0
B-4-0 4-7-0
9-2-0
4726-8-0 0 8-4-0
Plate Offsets (X Y)—
[2:0-0-2 Edge] [10:0-0-2 Edge]
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL.
in (loc) I/defl Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.59
Vert(LL)
0.33 14-15 >999 240
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.68
Vert(CT) -0.64 14-15 >652 180
BCLL 0.0
Rep Stress Incr YES
WB 0.59
Horz(CT)
0.13 10 n/a n/a
BCDL 10.0
Code FBC2017/TPI2014
Matrix -MS
Weight: 166 lb FT = 0%
LUMBER-
BRACING -
TOP CHORD 2x4 SP M 30
TOP CHORD
Structural wood sheathing directly applied or 3-1-15 oc purlins.
BOT CHORD 2x4 SP M 30
BOT CHORD
Rigid ceiling directly applied or 5-2-15 oc bracing.
WEBS 2x4 SP No.3
REACTIONS. (size) 2=0-8-0, 10=0-8-0
Max Horz 2=-179(LC 10)
Max Uplift 2=-775(LC 12), 10=-775(LC 12)
Max Gram 2=1399(LC 1), 10=1399(LC 1)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-3404/1963, 3-5=-2807/1637, 5-6=-2801/1739, 6-7=-2801/1739, 7-9=-2807/1637,
9-10=-3404/1963
BOT CHORD 2-17=-1724/3188, 15-17=-1724/3188, 14-15=-966/2053, 12-14=-1739/3188,
10-12=-1739/3188
WEBS 6-14=-560/968, 9-14=-681/524,6-15=-560/968,3-15=-681/524
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=70ft; L=35ft; eave=6ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-6-0, Interior(1) 2-6-0 to 17-6-0, Exterior(2) 17-6-0 to
21-0-0, Interior(1) 21-0-0 to 36-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip
This item has been
DOL=1.60
3) 100.01b AC unit load placed on the top chord, 17-6-0 from left end, supported at two paints, 5-0-0 apart.
electronically signed and
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
sealed by Albani, Thomas, PE
5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
using a Digital Signature.
will fit between the bottom chord and any other members, with BCDL = 10.Opsf.
Printed copies of this
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 775 lb uplift at joint 2 and 775 lb uplift at
joint 10.
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Thomas A. Alban! PE No.39380
MiTek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
March 24,2020
®WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII.7473 rev. 5119/2020 BEFORE USE.
Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and Is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design Into the overall
r
building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
MOW
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS1/TPI1 Quality Criteria, DSO.89 and BCSI Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601
Tampa, FL 36610
Job
Truss
Truss Type
Qty
Ply
THE WINDSOR
T19781810
M11392
B
COMMON
2
1
Job Reference o tional
Cnambers I runs, Inc., Tort Fierce, rL
11-0-0. 8-3-5
�1
0
o.tau s mars tutu ivu i eK muustnes, mu. i ue iwar t r rt:oy. io tutu
kfiGCA6bx7j2Syl HDXFw7ye3KX-5OwLjSh87_IziuFF2SVp01bSRwk4sA4MJ57c1
?1-0-0 26-8-11 35-0-0
3-6-0 5 8-11 8-3-5
Scale = 1:59.3
4.00 12 3x6 =
6
3x4 = 2x3 II 3x6 = 3x4 = 3x4 = 3x6 = 2x3 II 3x4 =
LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) Udefl L/d PLATES GRIP
TCLL 20.0 Plate Grip DOL 1.25 TC 0.34 Vert(LL) -0.11 14-15 >766 240 MT20 244/190
TCDL 7.0 Lumber DOL 1.25 BC 0.38 Vert(CT) -0.24 17-20 >715 180
BCLL 0.0 Rep Stress Incr YES WB 0.63 Horz(CT) 0.03 10 n/a n/a
BCDL 10.0 Code FBC2017rrP12014 Matrix -MS Weight: 149 lb FT = 20%
LUMBER- BRACING -
TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD 2x4 SP M 30 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 2x4 SP No.3
REACTIONS. All bearings 0-8-0.
(lb) - Max Horz 2=-179(LC 10)
Max Uplift All uplift 100lb or less atjoint(s) except 2=-371(LC 12), 15=-453(LC 12), 14=-453(LC 12), 10=-371(LC
12)
Max Grav All reactions 250 lb or less at joints) except 2=602(LC 1), 15=844(LC 17), 14=840(LC 18), 10=602(LC
1)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-945/572, 5-6=-181/256, 6-7=-181/258, 9-10=-945/574
BOT CHORD 2-17=-407/878, 15-17=-407/878, 12-14=-393/858, 10-12=-393/858
WEBS 3-17=-5/301, 3-15=-819/591, 5-15=-277/325, 7-14=-277/326, 9-14=-819/592,
9-12=-5/301
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=70ft; L=35ft; eave=5ft; Cat.
It; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Extedor(2) -1-0-0 to 2-6-0, Interior(1) 2-6-0 to 17-6-0, Exterior(2) 17-6-0 to
This item has been
21-0-0, Interior(1) 21-0-0 to 36-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip
DOL=1.60
electronically signed and
3) This truss has been designed fora 10.0 psf bottom chord live load nonconcurrent with any other live loads.
sealed by Albani, Thomas, PE
4) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
using a Digital Signature.
will fit between the bottom chord and any other members, with BCDL = 10.Opsf.
Printed copies of this
P
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 371 lb uplift at joint 2, 453 lb uplift at
joint 15, 453lb uplift at joint 14 and 371 lb uplift at joint 10.
document are not Considered
signed and sealed and the
signature must be verified
on any electronic copies.
Thomas A. Albani PE No.39380
MiTek USA, Inc. FL Cart 6834
6904 Parke East Blvd. Tampa FL 33610
Date:
March 24,2020
®WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 5/19/2020 BEFORE USE.
Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design into the overall r
building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek•
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSBTPH Quality Criteria, DSO.89 and SCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610
1 m
0
Job
Truss
Truss Type
Qty
Ply
T19781811
M11392
BHA
BOSTON HIP
1
1
�THEWINDSOR
Job Reference a tional
Chambers Truss, Inc., Fort Pierce, FL 8.240 s Mar 9 2020 MiTek Industries, Inc. Tue Mar 24 12:54:17 2020 Page 1
ID:—kfiGCA6bx7j2Syl HDXFw7ye3KX-2026BBiPXb?HzCPe9tXHTAgmFjM1 K3EfmPcjgXzXjGq
15.6-0 21-6-0
1.0-0 7-0-0 9-6-0 11$-0 13-6-0 1 -0 17-6-0 19-6-0 21-0-0 23-6.0 25-6-0 28-0-0 35-0-0 6-0.0
-0-0 7-" 2-6-0 2-0-0 2-0-0 0-6 1-6-0 2-0-0 2-0-0 1-0-0 2-0-0 2-0.0 2- 00 7-0-0 -0-0
Scale=1:62.4
TOP CHORD MUST BE BRACED BY END
ROOF DIAPHRAGM, OR PROPERLY COI`
PURLINS AS SPECIFIED.
3x4 =
:TE 4.00 12 4x4 =
57 15 58 17
56 12 59
3x6 55 9 20
548
5x12 =53 4 6 x6 = 3x4
3 11 16 11
1
52 4
60 22 3x6
2461 5x12
26
23 6-27
35 42 43 34 44 � 45 46 47 48 � 49 31 50 51 30
3x6 = 6x8 = 6x8 = 3x6 =
I!g
A
28 29 N N
I"7
0
3x4 =
7-0-0 14-0-0
21-0.0
28-0-0
35-0-0
7-0.0 7-0-0
7-0-0
7-0-0
7-0-0
Plate Offsets (X Y)—
[3:0-6-4 0-1-12] (32:0-3-8 0-3-0]
LOADING (pso
SPACING- 2-0-0
CS1.
DEFL.
in (loc)
I/deft
L/d
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.51
Vert(LL)
0.13 35-38
>999
240
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.54
Vert(CT)
-0.16 35-38
>999
180
BCLL 0.0
Rep Stress Incr NO
WB 0.65
Horz(CT)
0.04 28
file
n/a
BCDL 10.0
Code FBC2017/TPI2014
Matrix -MS
Weight: 208 lb FT = 0%
LUMBER- BRACING -
TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 5-3-13 oc purlins.
BOT CHORD 2x4 SP M 30 BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing.
WEBS 2x4 SP No.3 WEBS 1 Row at midpt 3-33, 27-32
JOINTS 1 Brace at Jt(s): 11, 19, 16, 7, 23
REACTIONS. All bearings 0-8-0.
(lb) - Max Horz 2=179(LC 7)
Max Uplift All uplift 100 lb or less at joint(s) except 2=-565(LC 8), 33=-1269(LC 8), 32=-1017(LC 8),
28=434(LC 8)
Max Grav All reactions 250 lb or less at joint(s) except 2=812(LC 17), 33=1825(LC 1), 32=1529(LC 1),
28=626(LC 1)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-1692/1103, 3-4=-1051259, 27-28=-1129/710, 3-5=441/520, 5-7=436/514,
7-10=436/514, 10-11=-436/514, 11-13=-436/514, 13-16=-436/514, 16-18=-436/514,
18-19=-436/514, 19-21=-382/412, 21-23=-382/412, 23-25=-382/412, 25-27=-387/418
BOT CHORD 2-35=-939/1572, 33-35=-909/1484, 32-33=-382/400, 30-32=-575/1004, 28-30=-568/1039
WEBS 3-35=-191/649, 27-30=0/451, 3-33=-2090/1523, 11-33=-810/782, 19-32=-772/745,
27-32=-1484/1044,9-10=4631453,20-21=-462/454
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=70ft; L=35ft; eave=6ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) All plates are 2x3 MT20 unless otherwise indicated.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 565 lb uplift at joint 2, 1269 lb uplift at
joint 33, 1017 lb uplift at joint 32 and 434 lb uplift at joint 28.
8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.
9) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 265 lb down and 381 lb up at
7-0-0, 158 lb down and 206 lb up at 9-0-12, 158 lb down and 206 lb up at 11-0-12, 158 lb down and 206 lb up at 13-0-12, 158 lb
down and 206 lb up at 15-0-12, 158 lb down and 206 lb up at 17-0-12, 158 lb down and 206 lb up at 17-11-4, 158 lb down and 206
lb up at 19-11-4, 158 lb down and 206 lb up at 21-11-4, 158 lb down and 206 lb up at 23-11-4, and 158 lb down and 206 lb up at
25-11-4, and 158 Ito down and 206 lb up at 27-11-4 on top chord, and 373 lb down and 236 lb up at 7-0-0, 69 lb down at 9-0-12, 69
lb down at 11-0-12, 69 lb down at 13-0-12, 69 lb down at 15-0-12, 69 lb down at 17-0-12, 69 lb down at 17-11-4, 69 lb down at
19-11-4, 69 lb down at 21-11-4, 69 lb down at 23-11-4, and 69 lb down at 25-11-4, and 69 lb down at 27-11-4 on bottom chord.
This item has been
electronically signed and
sealed by Albani, Thomas, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Thomas A. Albani PE No.39380
MiTek USA, Inc. FL Cart 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
March 24,2020
®C`�2tfYtdleVck�13s(gel;s;<dte(LEmrdF,SfBpplfeit-IB NA�f®CBLO(9biB11hFJS&O't�1F8��6ttlt7(�T� �V118t$2(i�BEFORE USE.
DQtri�l9yfl�lPyR�@rtl9F ��e¢d�p/qM�iTtye�kQ®y�connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not
a feli�d-t §i c rf sird�aitrl" g designer must verify the applicability of design parameters and properly Incorporate this design Into the overall MiTek*
bul l esi r rfg l i 9Is'to prevent buckling of individual truss web andfor chord members only. Additional temporary and permanent bracing IyliTe k•
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITP11 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610
Job
Truss
Truss Type
City
Ply
M11392
BHA
BOSTON HIP
1
1b
[HEWINDSORT19781811
Reference o tional
Chambers Truss, Inc., Fort Pierce, FL
ts.z4u s Mar a ZUZU IVu I eK Inuusines, Inc. I Ue wrar Z4 IZ:J4: I r ZULV rage Z
I D:_kfiGCA6bx7j2Sy1 HDXFw7ye3KX-202688iPXb?HzCPe9tXHTAgmFjM1 K3EfmPcjgXzXjGq
LOAD CASE(S) Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25
Uniform Loads (plf)
Vert: 36-39=-20, 1-3=-54, 3-15=-54, 15-27=-54, 27-29=-54
Concentrated Loads (lb)
Vert:35=-373(F) 30=-23(F) 42=-23(F) 43=-23(F)44=-23(F) 45=-23(F) 46=-23(F) 47=-23(F) 48=-23(F) 49=-23(F) 50=-23(F) 51=-23(F) 52=-169(F) 53=-118(F)
54=-118(F) 55=-118(F) 56=-118(F) 57=-118(F) 58=-118(F) 59=-118(F) 60=-118(F) 61=-118(F) 62=-118(F) 63=-118(F)
A WARNING -Verily design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 5/1912020 BEFORE USE.
Design valid for use only with MiTekO connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design into the overall p�
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing I VliTek•
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSUiP/f Quality Criteria, DSB-89 and BCS/ Building Component 6904 Parke East Blvd.
Safety information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610
Job
Truss
Truss Type
city
Ply
THE WINDSOR
T19781812
M11392
GRA
HIP
1
1
Job Reference o tional
GhamberS I fuss, Inc., FOR Marco, rL
7-0-0
5x12 MT18HS =
o.cyv a rvm, a tutu ry - Qy�
ID:_kfiGCA6bx7j2Syl HDXFw7ye3KX-_nAsZgkf3CG_CWZOHIZIYb17yXOVouLyEj5gvQzXjGo
21-5-2 28-0-0 35-M
6-6-2 6 6 14 7-0-0 -0-0
Scale = 1:60.3
4.00 12 3x5 I 3x6 = 4x8 =
3 22 23 24 25 4 26 27 5 28 629 30 31 32
4x8 =
7
15 33 34 14 35 13 36 37 38 1239 11 40 41 10
3x4 = 2x3 11 3x6 = 5x14 = 3x4 = 46 = 24 I I 36 =
35-M
LOADING (psf)
TCLL 20.0
TCDL 7.0
BCLL 0.0
BCDL 10.0
SPACING- - 2-0-0
Plate Grip DOL 1.25
Lumber DOL 1.25
Rep Stress Incr NO
Code FBC2017/TPI2014
CSI.
TC 0.94
BC 0.67
WB 1.00
Matrix -MS
DEFL. in (loc) Vdefi L/d
Vert(LL) 0.30 10-21 >792 240
Vert(CT) -0.30 10-12 >812 180
Horz(CT) 0.09 8 n/a n/a
PLATES
MT20
MT18HS
Weight: 153 lb
GRIP
244/190
244/190
FT = 20%
LUMBER-
BRACING -
TOP CHORD 2x4 SP M 30
TOP CHORD
Structural wood sheathing directly applied or 3-9-5 oc purlins.
BOT CHORD 2x4 SP M 30
BOT CHORD
Rigid ceiling directly applied or 4-6-8 oc bracing.
WEBS 2x4 SP No.3 *Except*
WEBS
1 Row at midpt 6-13
4-13: 2x6 SP No.2
2 Rows at 1/3 pts 3-13
REACTIONS. (size) 2=0-8-0, 13=0-8-0, 8=0-8-0
Max Horz 2=-78(LC 6)
Max Uplift 2=-448(LC 8), 13=-2442(LC 8), 8=-1159(LC 8)
Max Grav 2=755(LC 17), 13=3223(LC 1), 8=1225(LC 18)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-1534/729, 3-4=-1052/1347. 4-6=-1052/1347, 6-7=-1946/1834, 7-8=-2978/2565
BOT CHORD 2-15=-586/1423, 13-15=-596/1464, 12-13=-171011946, 10-12=-2359/2830,
8-10=-2329/2789
WEBS 3-15=-159/733, 3-13=-2917/1869, 4-13=-848/801, 6-13=-3504/3050, 6-12=-430/666,
7-12=-940/731, 7-10=489/690
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2), Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=70ft; L=35ft; eave=5ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional); porch right exposed; Lumber DOL=1.60 plate grip DOL=1.60
This item has been
3) Provide adequate drainage to prevent water ponding.
4) All plates are MT20 plates unless otherwise indicated.
electronically Signed and
5) This truss has been designed fora 10.0 psf bottom chord live load nonconcurrent with any other live loads.
Sealed by Alban!, Thomas, PE
6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
using a Digital Signature.
will fit between the bottom chord and any other members.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 448 lb uplift at joint 2, 2442 lb uplift at
Printed copies of this
joint 13 and 1159 lb uplift at joint 8.
document are not Considered
8) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 203 lb down and 329 lb up at
signed and sealed and the
7-0-0, 90111 down and 155 lb up at 9-0-12, 90 lb down and 155 lb up at 11-0-12, 90 lb down and 155 lb up at 13-0-12, 90 lb down
signature must be verified
and 155 lb up at 15-0-12, 90 lb down and 155 lb up at 17-0-12, 90 lb down and 155 lb up at 17-11-4, 90 lb down and 155 lb up at
on any electronic copies.
19-11-4, 90 lb down and 155 lb up at 21-11-4, 90 lb down and 155 lb up at 23-11-4, and 90 lb down and 155 lb up at 25-11-4, and
203 lb down and 329 lb up at 28-0-0 on top chord, and 452 lb down and 263 lb up at 7-0-0, 63 lb down and 3 lb up at 9-0-12, 63 lb
Thomas A. Alban! PE No.39380
down and 3 lb up at 11-0-12, 63 lb down and 3 lb up at 13-0-12, 63 lb down and 3 lb up at 15-0-12, 63 lb down and 3 lb up at
MITek USA, Inc. FL Cart 6634
17-0-12, 63 lb down and 3 lb up at 17-11-4, 63 lb down and 3 lb up at 19-114, 63 lb down and 3 lb up at 21-11-4, 63 lb down and.
6904 Parke East Blvd. Tampa FL 33810
3 lb up at 23-11-4, and 63 lb down and 3 lb up at 25-11-4, and 452 lb down and 263 lb up at 27-11-4 on bottom chord. The
Data:
design/selection of such connection device(s) is the responsibility of others.
March 24,2020
9) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).
,&kQ ri IAICASEP( siStlimd®t&rs and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 5119/2020 BEFORE USE.
Diil9ntf9Nftrtl� a Wuwt MlTek@ connectors. This design is based only upon parameters shown, and is for an Individual building component, not
a truss system. Bel re se, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
r
building design. Bracing indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
Wek'
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS11TPl1 Quality Criteria, DSB-89 and BCSI Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601
Tampa, FL 36610
Job
Truss
Truss Type
City
Ply
T19781812
M11392
GRA
HIP
1
1
�THEWINDSOR
Job Reference o tional
Chambers Truss, Inc., Fort Pierce, FL
is-z4u S mar v zuzu mi I eK mausmBS, Inc. I ue mar Z4 -i z:04:-i a GVGV rage z
ID:_kfiGCA6bx7j2Sy1 HDXFw7ye3KX-_nAsZgkf3CG_CWZOHIZIYbl?yXOVouLyEj5gvOzXjGo
LOAD CASE(S) Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25
Uniform Loads (plf)
Vert: 1-3=-54, 3-7=-54, 7-9=-54, 16-19=-20
Concentrated Loads (Ib)
Vert:3=-147(B) 7=-147(B) 15=-452(B)13=-40(B) 4=-90(B) 10=-452(B) 22=-90(B) 23=-90(B) 24=-90(B) 26=-90(B) 27=-90(B) 28=-90(B) 30=-90(B) 31=-90(B)
32=-90(B) 33=-40(B) 34=-40(B) 35=-40(B) 36=-40(B) 37=-40(B) 38=-40(B) 39=-40(B) 40=-40(B) 41=-40(B)
®WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 5/19/2020 BEFORE USE.
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an Individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall -
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek•
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS11TP/1 Quality Criteria, DSB-69 and BCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610
Job
Truss
Truss Type
Qty
Ply
THE WINDSOR
T19781813
M11392
AMONO
TRUSS
8
1
Job Reference o tional
Chambers Truss, Inc., Fort Pierce, FL
8.240 s Mar 9 2020 MiTek Industries, Inc. TUB Mar 24 12:54:19 2020 Page 1
I D:_kfiGCA6bx7j2Syl HDXFw7ye3KX-_nAsZgkf3CG_CWZOHIZIYblBwXAho7vyEj5gvQzXjGo
-1-0-0 1-0-0
1-0-0 1-0-0
3x4 =
Scale = 1:6.1
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in
(loc) I/defl L/d
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.18
Vert(LL) -0.00
5 >999 240
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.02
Vert(CT) -0.00
5 >999 180
BCLL 0.0
Rep Stress Incr YES
WB 0.00
Horz(CT) 0.00
4 file n/a
BCDL 10.0
Code FBC20171TP12014
Matrix -MP
Weight: 5 lb FT = 0%
LUMBER-
BRACING -
TOP CHORD 2x4 SIP No.3
TOP CHORD
Structural wood sheathing directly applied or 1-0-0 oc pudins.
BOT CHORD 2x4 SP No.3
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS. (size) 3=Mechanical, 2=0-8-0, 4=Mechanical
Max Horz 2=48(LC 12)
Max Uplift 3=-4(LC 9), 2=-140(LC 12)
Max Grav 3=11(LC 17), 2=118(LC 1), 4=17(LC 12)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=70ft; L=35ft; eave=6ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) zone;C-C for members and forces & MWFRS for reactions
shown; Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 pelf bottom chord live load nonconcurrent with any other live loads.
3) ' This truss has been designed for a live load of 20.Opsf on the bottom chard in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 4 lb uplift at joint 3 and 140 lb uplift at
joint 2.
This item has been
electronically signed and
sealed by Albani, Thomas, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Thomas A. Albani PE No.39380
MiTek USA, Inc. FL Cent 6834
6904 Parke East Blvd. Tampa FL 33610
Date:
March 24,2020
®WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5119/2020 BEFORE USE.
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design Into the overall MOW
k�
building design. Bracing indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing 1 V
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the IiT
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSUTP/f Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610
Job
Truss
Truss Type
Qty
Ply
T19781814
M11392
J3
MONO TRUSS
8
1
�THEWINDSOR
Job Reference o tional
Chambers Truss, Inc., Fort Pierce, FL 8.240 s Mar 9 2020 MiTek Industries, Inc. Tue Mar 2412:54:20 2020 Page 1
ID:_kfiGCA6bx7j2Syl HDXFw7ye3KX-SzkEmAIHgWOrgg8Dq?4_501MZxUHXa95SNgNRszXjGn
-1-0-0 3-0-0
1-0-0 3-0-0
3x4 =
LOADING (psf)
SPACING- 2-0-0
CSI.
TCLL 20.0
Plate Grip DOL 1.25
TC 0.18
TCDL 7.0
Lumber DOL 1.25
BC 0.19
BCLL 0.0 '
Rep Stress Incr YES
WB 0.00
BCDL 10.0
Code FBC2017/TP12014
Matrix -MP
LUMBER -
TOP CHORD 2x4 SP No.3
BOT CHORD 2x4 SP No.3
REACTIONS. (size) 3=Mechanical, 2=0-8-0, 4=Mechanical
Max Horz 2=85(LC 12)
Max Uplift 3=-54(LC 12), 2=-147(LC 12), 4=-4(LC 12)
Max Grav 3=64(LC 1), 2=173(LC 1), 4=50(LC 3)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
Scale = 1:9.4
DEFL.
in
(loc)
I/defi
L/d
PLATES GRIP
Vert(LL)
0.01
4-7
>999
240
MT20 244/190
Vert(CT)
-0.01
4-7
>999
180
Horz(CT)
-0.00
3
n/a
n/a
Weight: 11 lb FT = 0%
BRACING -
TOP CHORD Structural wood sheathing directly applied or 3-0-0 oc purlins
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
NOTES-
1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=70ft; L=35ft; eave=6ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-6-0, Interior(1) 2-6-0 to 2-11-8 zone;C-C for
members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 54 lb uplift at joint 3, 147 lb uplift at joint
2 and 4 Ito uplift at joint 4.
This item has been
electronically signed and
sealed by Albani, Thomas, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Thomas A. Albani PE No.39380
MiTek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33810
Date:
March 24,2020
®WARNING - Verlfy deslgn parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE.
Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not -
a truss system. Before use, the building designer must verify the applicability of design parameters and. property Incorporate this design Into the overall �8
building design. Bracing Indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MOW
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS11TPl! Quality Criteria, DSB-89 and BCS/ Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610
Job
Truss
Truss Type
city
Ply
THE WINDSOR
T19781815
M11392
J5
MONO TRUSS
8
1
Job Reference o tional
Chambers Truss, Inc., Fort Pierce, FL
1-M
3x4 =
LOADING (psf)
SPACING- 2-0-0
CSI.
TCLL 20.0
Plate Grip DOL 1.25
TC 0.73
TCDL 7.0
Lumber DOL 1.25
BC 0.70
BCLL 0.0
*
Rep Stress Incr YES
WB 0.00
BCDL 10.0
Code FBC2017/TP12014
Matrix -MP
LUMBER -
TOP CHORD 2x4 SP No.3
BOT CHORD 2x4 SP No.3
REACTIONS.
(size) 3=Mechanical, 2=0-8-0, 4=Mechanical
Max Horz 2=123(LC 12)
Max Uplift 3=-104(LC 12), 2=-177(LC 12), 4=-9(LC 12)
Max Grav 3=115(LC 1), 2=243(LC 1), 4=87(LC
3)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
8.240 s mar a 2020 Mirex industries, Inc. i ue rwar — rc.�.< r cucu Faye i
ID:_kfiGCA6bx7j2Sy1 HDXFw7ye3KX-wAHc_WlvbgWiRpjPOibDeOrOoKiYG1 PFh 1 awzlzXjGm
5-0-0 1
DEFL. in (loc) I/deft L/d
Vert(LL) 0.07 4-7 >863 240
Vert(CT) -0.06 4-7 >964 180
Horz(CT) -0.00 3 n/a n/a
Scale=1:12.7
PLATES GRIP
MT20 244/190
Weight: 17 lb FT = 0%
BRACING -
TOP CHORD Structural wood sheathing directly applied or 5-0-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
NOTES-
1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=70ft; L=35ft; eave=6ft; Cat.
11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-6-0, Interior(1) 2-6-0 to 4-11-8 zone;C-C for
members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 104 lb uplift at joint 3, 177 lb uplift at
joint 2 and 9 lb uplift at joint 4.
This item has been
electronically signed and
sealed by Albani, Thomas, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Thomas A. Albani PE No.39380
MiTek USA, Inc. FL Cart 6834
6904 Parke East Blvd. Tampa FL 33610
Date:
March 24,2020
®WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE.
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and Is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall t� V I
building design. Bracing indicated Is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing IV1iTelc
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS11TP/1 Quality Criteria, DSB-89 and BCS/ Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610
Job
Truss
Truss Type
Qty
Ply
THE WINDSOR
T19781816
M11392
J7
MONO TRUSS
24
1
Job Reference o tional
Chambers Truss, Inc., Fort Pierce, FL
3x4 =
8.240 s Mar 9 2020 MiTek Industries, Inc. Tue Mar 24 12.54.21 2020 Page 1
ID:_kfiGCA6bx7j2Syl HDXFw7ye3KX-wAHc_WlvbgWiRpjPOibDeOrSnKmPG1 PFh 1 awzlzXjGm
7-0-0
7-0-0
Scale: 3/4"=1'
7-0-0
7-M
Plate Offsets (X Y)— [2:0-1-14 Edge]
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in
(loc) I/deft L/d
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.47
Vert(LL) 0.17
4-7 >494 240
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.39
Vert(CT) -0.19
4-7 >447 180
BCLL 0.0
Rep Stress Incr YES
WB 0.00
Horz(CT) -0.00
3 We n/a
BCDL 10.0
Code FBC2017/TPI2014
Matrix -MP
Weight: 23 lb FT = 0%
LUMBER-
BRACING -
TOP CHORD 2x4 SP M 30
TOP CHORD
Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD 2x4 SP M 30
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS. (size) 3=Mechanical, 2=0-8-0, 4=Mechanical
Max Horz 2=161(LC 12)
Max Uplift 3=-153(LC 12), 2=-211(LC 12), 4=-12(LC
12)
Max Grav 3=165(LC 1), 2=315(LC 1), 4=125(LC 3)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=70ft; L=35ft; eave=6ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-6-0, Interior(1) 2-6-0 to 6-11-8 zone;C-C for
members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 153 lb uplift at joint 3, 211 lb uplift at
joint 2 and 12 lb uplift at joint 4.
This item has been
electronically signed and
sealed by Albani, Thomas, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Thomas A. Albani PE No.39380
MiTek USA, Inc. FL Cart 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
March 24,2020
®WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE 10II.7473 rev. 5/19/2020 BEFORE USE.
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an Individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design into the overall Ar
building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing 1 VliTek•
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS11TP/1 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610
Job
Truss
Truss Type
Qty
Ply
THE WINDSOR
•
T19781817
M11392
KJ7
MONO TRUSS
4
1
Job Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL 8.240 s Mar 9 2020 MiTek Industries, Inc. T ue Mar 24 12:54:22 2020 Page 1
ID:_kfiGCA6bx7j2Sy1HDXFw7ye3KX-OMr BsmXM7eZ3zibyQ7SADNhnk9g?RvOwhJUWIzXjGI
-1-5-0 6-8-12 9-10-1
1-5 0 6-8-12 3-1-5
3x4 =
5
3x4 =
Scale=1:20.6
6-8-12
3-1-5
LOADING (psf)
SPACING- 2-0-0
CS1.
DEFL. in
(loc) I/defl L/d
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.20
Vert(LL) -0.04
7-10 >999 240
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.26
Vert(CT) -0.08
7-10 >999 180
BCLL 0.0 '
Rep Stress Incr NO
WB 0.24
Horz(CT) 0.01
5 n/a n/a
BCDL 10.0
Code FBC20171TP12014
Matrix -MS
Weight: 38 lb FT = 0%
LUMBER-
BRACING -
TOP CHORD 2x4 SP M 30
TOP CHORD
Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD 2x4 SP M 30
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 2x4 SP No.3
REACTIONS. (size) 4=Mechanical, 2=0-11-5, 5=Mechanical
Max Horz 2=192(LC 8)
Max Uplift 4=-131(LC 8), 2=-262(LC 8), 5=-238(LC 8)
Max Grav 4=156(LC 13), 2=379(LC 1). 5=461(LC 1)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-838/366
BOT CHORD 2-7=-487/798, 6-7=-487/798
WEBS 3-7=0/307, 3-6=-920/561
NOTES-
1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=70ft; L=35ft; eave=6ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 131 lb uplift at joint 4, 262 lb uplift at
joint 2 and 238 lb uplift at joint 5.
6) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).
LOAD CASE(S) Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25
Uniform Loads (plf)
Vert: 1-2=-54
Trapezoidal Loads (plf)
Vert: 2=0(F=27, B=27)-to-4=-133(F=-39, B=-39), 8=0(F=10, B=10)-to-5=-49(F=-15, B=-15)
This item has been
electronically signed and
sealed by Albani, Thomas, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Thomas A. Alban! PE No.39380
MiTek USA, Inc. FL Cart 6834
6904 Parke East Blvd. Tampa FL 33610
Date:
March 24,2020
® WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE 14II-7473 rev. 5/19/2020 BEFORE USE.
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and Is for an Individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall r
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek•
Is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSYTP11 Quality Crlferia, DSB-89 and BCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610
Symbols
PLATE LOCATION AND ORIENTATION
Center plate on joint unless x, y
offsets are indicated.
Dimensions are in ft-in-sixteenths.
Apply plates to both sides of truss
and fully embed teeth.
Ole
-
-I-
For 4 x 2 orientation, locate
plates 0- 1r15' from outside
edge of truss.
This symbol indicates the
required direction of slots in
connector plates.
" Plate location details available in MiTek 20/20
software or upon request.
PLATE SIZE
The first dimension is the plate
4 X 4 width measured perpendicular
to slots. Second dimension is
the length parallel to slots.
LATERAL BRACING LOCATION
Indicated by symbol shown and/or
by text in the bracing section of the
output. Use T or I bracing
if indicated.
BEARING
Indicates location where bearings
(supports) occur. Icons vary but
reaction section indicates joint
number where bearings occur.
Min size shown is for crushing only.
Industry Standards:
ANSI/TP11: National Design Specification for Metal
Plate Connected Wood Truss Construction.
DSB-89: Design Standard for Bracing.
BCSI: Building Component Safety Information,
Guide to Good Practice for Handling,
Installing & Bracing of Metal Plate
Connected Wood Trusses.
Numbering System
6-4-8 dimensions shown in ft-in-sixteenths
(Drawings not to scale)
1 2 3
TOP CHORDS
C1-2 C2-3
N WEBS, 4 0 NN
LL
; yes g O
U ��e c5 M
EL
a
O ci-e c6a C5-6 00
BOTTOM CHORDS
JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE
AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO
THE LEFT.
CHORDS AND WEBS ARE IDENTIFIED BY END JOINT
NUMBERS/LETTERS.
PRODUCT CODE APPROVALS
[CC -ES Reports:
ESR-1311, ESR-1352, ESR1988
ER-3907, ESR-2362, ESR-1397, ESR-3282
Trusses are designed for wind loads in the plane of the
truss unless otherwise shown.
Lumber design values are in accordance with ANSI/TPI 1
section 6.3 These truss designs rely on lumber values
established by others.
© 2012 MiTek® All Rights Reserved
z
a
MiTek Engineering Reference Sheet: Mll-7473 rev. 5/19/2020
® General Safety Notes
Failure to Follow Could Cause Property
Damage or Personal Injury
1. Additional stability bracing for truss system, e.g.
diagonal or X-bracing, is always required. See BCSI.
2. Truss bracing must be designed by an engineer. For
wide truss spacing, individual lateral braces themselves
may require bracing, or alternative Tor I
bracing should be considered.
3. Never exceed the design loading shown and never
stack materials on inadequately braced trusses.
4. Provide copies of this truss design to the building
designer, erection supervisor, property owner and
all other interested parties.
5. Cut members to bear tightly against each other.
6. Place plates on each face of truss at each
joint and embed fully. Knots and wane at joint
locations are regulated by ANSIfrPl 1.
7. Design assumes trusses will be suitably protected from
the environment in accord with ANSI/TPI 1.
8. Unless otherwise noted, moisture content of lumber
shall not exceed 19% at time of fabrication.
9. Unless expressly noted, this design is not applicable for
use with fire retardant, preservative treated, or green lumber.
10. Camber is a non-structural consideration and is the
responsibility of truss fabricator. General practice is to
camber for dead load deflection.
11. Plate type, size, orientation and location dimensions
indicated are minimum plating requirements.
12. Lumber used shall be of the species and size, and
in all respects, equal to or better than that
specified.
13. Top chords must be sheathed or purlins provided at
spacing indicated on design.
14. Bottom chords require lateral bracing at 10 ft. spacing,
or less, if no ceiling is installed, unless otherwise noted.
15. Connections not shown are the responsibility of others.
16. Do not cut or alter truss member or plate without prior
approval of an engineer.
17. Install and load vertically unless indicated otherwise.
18. Use of green or treated lumber may pose unacceptable
environmental, health or performance risks. Consult with
project engineer before use.
19. Review all portions of this design (front, back, words
and pictures) before use. Reviewing pictures alone
is not sufficient.
20. Design assumes manufacture in accordance with
ANSI/TPI 1 Quality Criteria.
21.The design does not take into account any dynamic
or other loads other than those expressly stated.