HomeMy WebLinkAboutAPPROVED Polyglass MTS Business &
Professional Regulation
OCIS Home Log In User Registration Hot Topics Submit Surcharge Scats&Facts Publications Contact Vs BCIS Site Map r Unks Search
ba
Product Appro►ral pr
USER'Public user
dint A22tgyal Mey>Pmduct of QQ11cation Search>AAppI catien List�Application Detail
11111 FL# FL5259-R29
Application Type Revision
Code Version 2017
Application Status Approved
Comments
Archived
Product Manufacturer POLYGLASS USA
Address/Phone/Email 1111 W. Newport Center Drive
Deerfield Beach, FL 33442
(954)233-1330 Ext242
malpert@polyglass.com
Authorized Signature Maury Alpert
ma Ipert@palyg lass.com
Technical Representative TECH REP
Address/Phone/Email 1111 West Newport Center Drive
Deerfield Beach, FL 33442
(866)802-8017
uspolyglasstechnical@polyglass.com
Quality Assurance Representative QA REP
Address/Phone/Email 1111 West Newport Center Drive
Deerfield Beach, FL 33442
(888)410-1375
uspolyglasstechnical@polyglass.com
Category Roofing
Subcategory Underlayments
Compliance Method Evacuation Report From a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed the Robert Nieminen
Evaluation Report
Florida License PE-59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 10/21/2022
Validated By John W. Knezevich, PE
Validation Checklist-Hardcopy Received
Certificate of independence EL5259 R29 CQI, 2019 01 ,Q$)I NIEMINE .p
Referenced Standard and Year(of Standard) Standard year
ASTM D1970 2015
ASTM D226 2009
ASTM D4798 2011
ASTM D6163 2008
ASTM D6164 2011
ASTM D6222 2011
ASTM D6509 2009
FM 4474 2011
FRSA/TP1 April 2012 2012
UL1897 2012
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted 10/15/2019
Date Validated 10/16/2019
Date Pending FBC Approval 10/20/2019
Date Approved 12/10/2019
Summary of Products
FL* Model,Number or Name Description
5259.1 Polyglass Roof Roofing underiayments
Underiayments
Limits of UseInstallation Instructions
Approved for use in HVHZ: No FL529 R29 II 2019 10 FINAL ER POLYGLASS [JNOERLAYMENTS FL5254-
Approved for use outside HVHZ: Yes R29.Q�f
Impact Resistant: N/A Verified By: Robert Nieminen PE-59166
Design Pressure: +N1AJ-622.5 Created by Independent Third Party:Yes
Other: 1.)The design pressure in this Evaluation Reports
application relates to one particular F€5259 R29 AE 2019 10 FINAL ER POLYGLASS UNDERLAYMENTS FL5259-;
underlayment system (over concrete deck)for
use under foam-on tile systems(where the I Created by Independent Third Party:Yes
underlayment forms part of the load-path).
Refer to ER Section 5.6.1 for other systems,
other deck types and associated maximum
design pressures.2.)Refer to ER Section 5 for
other limits of use.
sack Hex1'
contact y ::2601 Blair Stone Road.Tallahassee FL V399 Ph❑ne:850.487-1824
The State of Florida is an AIVEE0 employer.Cogyriuht 2007-2013 State of norlda,::Pn-VaCV Statement::Acoessibil ty Statement::Refund Statement
Under Florlde law,email addresses are public records.If you do not want your a-mall address released in response to a public-records request,do not send electronic
mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questlons,please contact 850.487.139S."Pursuant to Section 455,275(1],
Florida statutes,effective iJctober 1,2012,liven sees licensed under Chapter 4SS,F.5-must provide the Department with an email address if they have one.The emails
provided may be used for ofclal communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please
provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please dick here.
Product Appraval Accepts:
®cl ® Et
Credit Card
Safe
N EMO I etc,
Certificate of Authorization#32455
353 Christian Street, Unit#13
00 Oxford, CT 06478
(203) 262-9245
ENGINEER EVALUATE TEST CONSULT CERTIFY
EVALUATION
Polyglass USA,Inc. Evaluation Report P12060.02.09-R25
1111 West Newport Center Drive FL5259-R29
Deerfield Beach,FL 33442 Date of Issuance:02/24/2009
(954)233-1230 Revision 25: 10/14/2019
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen,P.E.for
use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described
herein have been evaluated for compliance with the 6th Edition(2017)Florida Building Code sections noted herein.
DESCRIPTION: Polyglass Roof Underlayments
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced
Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this
Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. of any changes to the
product(s), the Quality Assurance or the production facility location(s). NEMO I etc. requires a complete review of this
Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "NEMOletc. Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its
distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 16.
Prepared by:
Robert J.M. Nieminen, P.E. :s
Florida Registration No.59166,Florida❑CA ANE1983 ....... The facsimile seal appearing was authorized by Robert Nieminen,P.E.on
10/14/2019, This does not serve as an electronically signed document.
CE"FICATIDN OF INDEPENDENCE:
1. NEMOI etc. does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. NEMOIetc. is not owned,operated or controlled by any company manufacturing or distributing products it evaluates.
1 Robert Nieminen,P.E.does not have nor wi11 acquire,a financial Interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither NEM01 etc. nor Robert Nieminen, P.E. are, in any way,the Designer of Record for any
project on which this>valuation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained
specifically for that purpose.
02019 MEMO ETC,LLC
ONEMOletc.
EVALUATIONROOFING COMPONENT
Z. SCQPE.
Product Category: Roofing
Sub-Category; Underlayment
Compliance Statement: Roof Underlayments, as produced by Polyglass USA, Inc., have demonstrated compliance with the
following sections of the fith Edition (2017) Florida Building Code through testing in accordance with the following Standards,
Compliance is subject to the Installation Requirements and Limitations Conditions of Use set forth herein.
Z. STANDARDS:
Section Property Standard Year
1504.3.1 Wind Uplift FM 4474 2011
1504.3.1 Wind Uplift UL 1897 2012
1507.2.3/1507.1.1 Physical Properties ASTM D226 2009
1507.2.4 1 1507,1A,1507.2.9.2 Physical Properties ASTM D1970 2015
1507.3.3 Physical Properties FRSA/TRI April 2012 2012
1507.11.2 Physical Properties ASTM D6163 2008
1507.11.2 Physical Properties ASTM D6164 2011
1507.11.2 Physical Properties ASTM]D6222 2011
1507.11.2 Physical Properties ASTM D6509 2009
TAS 110 Accelerated Weathering ASTM D4798 2011
3. REFERENCES:
Enter Examination rence Date Ent Exam{ a�tion Reference Date
ERD(TST 6049) Wind Uplift 11757.09.01-1 08/13/2001 ERD(TST 6049) Tensile adhesion P40390.04.15 04/03/2015
ERD(TST 6049) Wind Uplift 11776.06.02 01/15/2003 ERD(TST 6049) TAS 103 P44360.10.14-RI 05/19/2015
ERD(TST 6049) Wind Uplift P1740.01,07 ol/04/2007 ERD(TST 6049) Wind Uplift PLYG-SC8905,05.16.1 05/17/2016
ERD(TST 6049) ASTM D1970 P5110,04.07.1 04/11/2007 ERD(T5T 6049) ASTM D1970 PLYG-SC10130.06.16-1 06/27/2016
ERD(TST 6049) Wind Uplift P9260.03.08 03/21/2008 ERD{TST 6049) Tensiie adhesion PLYG-SC10130.06A6-Z 06/27/2016
ERD(TST 6049) Wind Uplift P30540,11.09-111 11/30/2009 ERD(TST 6049) TAS 10-1 PLYG-SC1O130.06.16-3 06/27/2016
ERD(TST 6049) Tensile Adhesion P11030.11.09-1 11/30/2009 ERD(TST 6049) ASTM 01970/D4798 PLYG-SC8080.07.16 07/16/2016
ERD(TST 6049) Wind Uplift P11030,11.09-2 11/30/2009 ERD(TST 6049) Wind Uplift PLYG-SC12025.10.16 10/12/2016
ERD(TST 6049) ASTM D4977 P11030,11.09.3 11/30/2009 ERD(TST 6049) TAS 103 PLYG-SC13040.12.16 12/27/2015
ERD(TST 6049) ASTM D1970 P33360.06.10 06/25/2010 ERD(TST 60491 30190 physicals PLYG-SC11900.03,17 03/10/2017
ERD(TST 6049) TAS 103 P33370.03.11 03/02/2011 ERD(TST 6049) TAS 103 PLYG-SC12115-08.17 08/08/2017
ERD(TST 6049) Tensile Adhesion P33370-04.11 D4/26/2011 ERD(TST 6049) TAS 103 PLYG-SC13035.08.17 10/31/2017
ERD(TST 6049) ASTM D1970 P37300.10.11 10/19/2011 FM(TST 1967) Wind Uplift 3004091 01/12/2000
ERD(TST 6049) TAS 103 P40390.08.12-1 08/06/2012 ICC-ES(EVIL 2396) IBC Compliance ESR-1697 04/01/2019
ERD(TST 6049) Tensile Adhesion P40390.08.12-2 08/07/2012 M-D(CER 1592) HVHZ Compliance NUA 17-0614,22 07/06/2017
ERD(TST 6049) Tensile Adhesion C41420.09.12-3 09/11/2012 MTI(TST 2509) ASTM 04798 JX20117A D4/01/2008
ERD(TST 6049) Wind Uplift P39680.03.13 03/04/2013 NEMD(TST 6049) ASTM D1970 4-PLYG-18.004.03,19 03/29/2018
ERD(TST 6049) A57M D1970 P45370.04,13 04/26/2013 NEMD(TST 6049) Wind Uplift 4L-PLYG-18-0O3,D1.19 01/11/2019
ERD(TST 6049) Wind Uplift P1738.02.07-112 04/29/2013 NEMD(TST 6049) ASTM D6163 4S-PLYG-18.002.01.19-A 01/24/2019
ERD(TST 6049) Wind Uplift 11757.04.01-1-R1 04/30/2013 NEMD(TST 6049) ASTM D6222 4S-PLYG-18-002.05.19-C 05/20/2019
ERD(TST 6049) ASTM 06164 P37590-03.13.3A 05/06/2013 NEMa(TST 6049) TAS 103 45-PLYG-18-004.10.19-G 10/08/2019
ERD(TST 6049) ASTM D6509 P37590.03.13.1-R1 06/26/2013 NEMD(TST 6049) TAS 103 4S-PLYG-18-004.10.19-I 10/08/2019
ERD(TST 6049) Wind Uplift P41630.08.13 08/06/2013 N£MO(TST 6049) TAS 103 45-PLYG-18-004.10,19-L 10/09/2019
ERD(TST 6049) ASTM D4501 P45940.09.13 09/04/2013 NEMD(TST 6049) TAS 103 4j-PLYG-I9-SSUDL-01.A 10/10/2019
ERD(TST 6049) Wind Uplift P11751.05.03-R1 11/26/2013 PRI(TST 5878) Tensile Adhesion PRIO1111 04/08/2002
ERD(TST 6049) Wind Uplift P11781.11.03-RI IV26/2013 PRI(TST 5878) TAS 103 PU5A-018.02-01 07/14/2003
ERD(TST 6049) 30190 physicals P45270,05.14 05/12/2014 PRI{TST5878) TAS 103 PUSA-035-02-01 09/29/2006
ERD(TST 6049) Tensile adhesion 6020.09,14-5 09/(38/2014 PRI(TST 5979) TAS 103 PUSA-055-02-02 12/10/2007
ERD(TST 6049) Tensile adhesion 6020.09.14-6 09/08/201.4 PRl(TST 5979) ASTM D6222 PU5A-061.02-02 01/28/2008
ERD(TST 6049) Tensile adhesion P46520.10.14 10/03/2014 PRI(TST 5878) ASTM 06164 PUSA-089-02-01 07/29/2009
ERD(TST 6049) ASTM D1970/04798 P43290,10.14 10/1712014 Polyglass USA P/L Affidavit Mule-Hide Cross Ltg 03/Ol/2008
NEMD ETC,LLC. Evaluation Report P12060,02.09-1125
Certificate ofAuthoritofion N3.2455 CH EDITION(2017)FBC NON-HV14Z EVALUATION FL5Z59-R29
Polyglass Roof Undertayments;(954)233-1230 Revision 25:10114/2019
Page 2 of 16
ONEMOjetc.
Enfltv Examination Reference Date Entftv Examination Reference Date
ERD(TST 6049) TAS 103 PLYG-SC7550.03.15 03/24/2015 Polyglass USA Materials Affidavit Polystick Compound 08/18/2011
UL(QUA9625) quality Control Service Confirmation 0911312018
4. PRODucr IDESCRIPTidN:
Product Specification Plant(s) Description
4.1 Elastobase ASTM D6163 FL Fiberglass-reinforced,SBS modified bitumen base sheet
4.2 Elastobase P ASTM D6164 FL Polyester-reinforced,SBS modified bitumen base sheet
4.3 Elastoflex G TU M-D 13-004 PA Polyester-reinforced,modified bitumen tile underlayment
FRSA/TRI April 2012 composed of a sand-surfaced SBS modified bitumen back-
side and granule-surfaced APP modified bitumen top-side
4.4 Elastoflex 56 G ASTM D6164 FL Polyester-reinforced,SBS modified bitumen cap sheet
FRSA/TRI April 2012
4.5 Elastoflex S6 G FR ASTM D6164 FL Polyester-reinforced,SBS modified bitumen cap sheet
FRSA/TRI April 2012
4.6 Mule-Hide SA-APP Cap Sheet ASTM D6222 FL Polyester-reinforced,APP modified bitumen cap sheet
FRSA/TRI April 2012
4.7 HydraGuard Dual Pro ASTM D1970 FL Nominal 60-mil thick dual-layer rubberized asphalt
waterproofing membrane,fiberglass reinforced,with a
polyester fabric surface
4.8 HydraGuard Tile Pro ASTM D1970 FL Nominal 60-mil thick dual-layer rubberized asphalt
TAS 103 waterproofing membrane,fiberglass reinforced,with a
FRSA/TRI April 2012 polyester fabric surface
4.9 Mule-Hide SA-APP Cap Sheet ASTM D6222 FL Polyester-reinforced,APP modified bitumen cap sheet
(FR) FRSA/TRI April 2012
4.10 Polyflex G ASTM D6222 FL Polyester-reinforced,APP modified bitumen cap sheet for
FRSA/TRI April 2012 use as an alternate to Neat Applied"Cap Sheet"in the
"Two Ply System"from FRSA/TRI April 2012(04-12)
beneath mechanically fastened or adhered tile roof
systems
4.11 Polyflex G FR ASTM D6222 FL Polyester-reinforced,APP modified bitumen cap sheet for
FRSA/TRI April 2012 use as an alternate to Heat Applied"Cap Sheet"in the
"Two Ply System"from FRSA/TRI April 2012(04-12)
beneath mechanically fastened the roof systems
4.12 Polyflex SA P ASTM D6222 FL Polyester-reinforced,APP modified bitumen cap sheet
FRSA/TRI April 2012
4.13 Polyflex SA P FIR ASTM D6222 FL Polyester-reinforced,APP modified bitumen cap sheet
FRSA/TRI April 2012
4.14 Polyglass Base ASTM D6509 FL Fiberglass-reinforced,APP modified bitumen base sheet
4.15 Polyglass G2 Base Sheet ASTM D4601 AL Fiberglass-reinforced,asphaltic base sheet
4.16 Polystick IR-Xe ASTM D1970 FL,PA Nominal 60-mil thick rubberized asphalt waterproofing
membrane,glass fiber reinforced,with an aggregate
surface
4.17 Polystick MT5 Plus TAS 103 FL,PA,TX Nominal 60-mil thick rubberized asphalt waterproofing
FRSA/TRI April 2012 membrane,glass fiber reinforced,surfaced with
polyolefinic film surface
MEMO ETC,I.I.C. Evaluation Report P12060,02.09-1125
C'ertifiicateojAuthonration 932455 fit"EDITION(2017)FBC NON-HVHZ EVALUATION FL5259-R29
Polyglass Roof underiayments;(954)233-1230 Revision 25:10/14/2019
Page 3 of 16
NNEMOletc.
4. PRODUCT DESCRIPTION:
Product Specification Plant(s) Description
4.18 Polystick MU-X ASTM D1970 FL,NV,PA Nominal 54-mil thick dual-layer rubberized asphalt
(See Section S.8) waterproofing membrane,fiberglass reinforced,with a
polypropylene film surface
4.19 Polystick TU Max ASTM D1970 FL, PA,TX Nominal 60-mil thick rubberized asphalt waterproofing
TAS 103 membrane with a 190 g/m2 polyester fabric surface
FRSA/TRI April 2012
4.20 Polystick TU P TAS 103 TX Nominal 130-mil thick rubberized asphalt waterproofing
FRSA/TRI April 2012 membrane,glass-fiber/polyester reinforced,with a
granular surface
4.21 Polystick TU Plus ASTM D1970 FL,PA Nominal 80-mil thick rubberized asphalt waterproofing
TAS 103 membrane,glass fiber reinforced,with a polyester fabric
FRSA/TRI April 2012 surface
S. DMITATIONS:
5.1 This is a building code evaluation. Neither NEM01etc. nor Robert Nieminen,R.E.are,in any way,the Designer of Record for any
project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless
retained specifically for that purpose.
5.2 This Evaluation Report is not for use in the HVHZ.
5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory for fire ratings of
this product.
5.4 Polyglass Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced within
FBC approval documents. If not listed,a request may be made to the Authority Having Jurisdiction for approval based on this
evaluation combined with supporting data for the prepared roof covering,
5.5 Allowable Roof Covers:
TABLE 1: ROOF COVER OPTIONS
Wood Shakes
Underlayment Asphalt Shingles Nail-On The Foam-On Tile Metal &Shingles state
Elastobase Yes Yes Yes
Base Sheet in 2 tem Yes Yes Yes
( -plY sys � (Base Sheet In 2-ply system)
Elastobase P Yes Yes Yes
Yes Yes Yes
(Base Sheet in 2-ply system) (Base Sheet in z-ply system)
Polyglass Base No Yes Yes No No No
(Base Sheet in 2-ply system) (Base Sheet in 2-ply system}
Polyglass G2 Base No Yes Yes No No No
(Base Sheet In 2-ply system) (Base Sheet In 2-ply system)
Elastoflex G TU Yes Yes Yes (See 5.5.1) No Yes Yes
Elastoflex 56 G Yes Yes Yes (See 5.5.1) No Yes Yes
Elastoflex 56 G FR Yes Yes No No Yes Yes
HydraGuard Dual Pro Yes No No Yes Yes Yes
HydraGuard Tile Pro Yes Yes Yes (See 5.5.1) Yes Yes Yes
Mule-Hide SA-APP Cap
Sheet Yes Yes Yes (See 5,5,1) Na Yes Yes
Mule-Hide SA-APP Cap Yes Yes Yes (See 5.5.1) No Yes Yes
Sheet(FR)
Polyflex G Yes Yes Yes (See 5.5.1) No Yes Yes
Polyflex G FR Yes Yes No No Yes Yes
Polyflex SA P Yes Yes Yes (See 5.5.1) No Yes Yes
Polyflex SA P FR Yes Yes Yes (See 5.5.1) No Yes Yes
Polystick 1R-Xe Yes No No No Yes Yes
NENEO ETC,LLC. Evaluation Report P12064.42.09-1125
Certificote of Authorization432455 5:"EDITION(2t617)FSC NON-11VHI EVALUATION FL5259-1129
Polyglass Raof Underlayments;(954)233-1230 Revision 25:10/14/2019
Page 4 of 16
NNEMOjetc.
TABLE 1: ROOF COVER OPTIONS
Wood Shakes
Underlayment Asphalt Shingles Nail-On Tile Foam-On Tile Metal &5h[ngles $into
Polystick MTS Plus Yes Yes No Yes Yes Yes
Polystick MU-X Yes No No Yes Yes Yes
Polystick TU Max No Yes Yes (See 5.5.1) Yes No No
Polystick TU P No Yes Yes (See 5.5.1) No No No
Polystick TU Plus Yes Yes Yes (See 5.5.1) Yes Yes Yes
5.5.1 "Foam-On Tile"is limited to use of the following Approved tile adhesives/underlayment combinations.
TABLE IA:ALLOWABLE TILE ADHESIVE/UNDERLAYMENT COMBINATIONS'
Florida Product
Adhesive Approval Underlayments
DAP Foam Touch'n Seal StormBond FL14506 Polystick TU Max or Polystick TU Plus
Roof Tile Adhesive
Dow Tile Bond— FL22525 HydraGuard Tile Pro,Polyflex SA P,Polystick TU Max,Polystick TU P or
Polystick TU Plus
Elastoflex G TU,Elastoflex S6 G,HydraGuard Tile Pro,Mule-Hide SA-APP
ICP Adhesives Polyset®AH-160 FL6332 Cap Sheet,Mule-Hide SA-APP Cap Sheet(FR),Polyflex G,Polyflex SA P,
Polyflex SA P FR,Polystick TU Max,Polystick TU P or Polystick TU Plus
THJad,
oflex S6 G,HydraGuard Tile Pro,Mule-Hide SA-APP Cap Sheet,Mule-
ICP Adhesives Polyset*RTA-1 FL6276 SA-APP Cap Sheet(FR),Polyflex G,Polyflex SA P,Polyflex SA P FR,
tick TU Max,Polystick TU P or Polystick TU Plus
5.6 Allowable Substrates:
TABLE 2: SUBSTRATE OPTIONS FOR ADHERED UNDERLAYMENTS
Underlayment Application Substrates(designed to meet wind loads for project)
Type Primer Material(S)
plywood,OSB,Southern Yellow Pine or Huber
HydraGuard Dual Pro, Deck/ (Optional)ASTM D41 Engineered Woods"ZIP System"Panels
HydraGuard Tile Pro, sheathing
Polystick(all variations), ASTM D41 structural concrete
self-Mule-Hide SA-APP Cap (Optional)ASTM D41 ASTM C1289 Type 11 Class 1 palyisocyanurate,ASTM
Sheet,Mule-Hide SA-APP adhering Insulation or W8-3000 C1289 Type V polyisocyanurate-composite,DensDeck
Cap Sheet(FR),Polyflex Prime or SECUROCK Gypsum-Fiber Roof Board
SA P or Polyflex 5A P FR Base N/A ASTM D226 felt,Elastobase,Elastobase P or Mule-Hide
Sheet Nail Base
Deck ASTM D41 structural concrete
Elastoflex G TU,E last oflex hot asphalt Insulation (Optional)ASTM D41 DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board
56 G or Elastoflex 56 G FR Base N/A ASTM D226 felt,Elastobase,Elastobase P,Mule-Hide Nail
Sheet Base or Polyglass G2 Base
Deck ASTM D41 structural concrete
Polyflex G or Polyflex G FR torch- Insulation (Optional)ASTM D41 DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board
applied Base Elastobase,Elastobase P,Mule-Hide Nail Base,Polyglass
Sheet N/A G2 Base or Polyglass Base
Refer to Tile Manufacturer's or Adhesive Manufacturer's Florida Product Approval for Overturning Moment Resistance Performance.
NEMA ETC,LLC. Evaluation Report P12060.02.49-1125
Certificate of Authorization#32455 a EDITION(2017)FBC NON-HVHI EVALUATION FL5259-R29
Polyglass Roof Underlayments,(954)233-1230 Revislon 25:10/14/2019
Page 5 of 16
ONEMOletc.
5.6.1 Wind Resistance for Underla meat Systems in Foam-On Tile AP plications:
The following wind uplift limitations apply to underlayment systems that are not prescriptively addressed in FRSA/TRI April
2012(04-12) and are used in foam-on or mortar-set tile applications, Maximum Design Pressure is the result of testing for
wind load resistance based on allowable wind loads and reflects the ultimate passing pressure divided by 2(the 2 to 1 margin
of safety per FBC 1504.9 has already been applied), Refer to FRSA/TRI April 2012(04-12),Appendix A,Table 1A or FBC 1609
for determination of design wind loads,
#1 Maximum Design Pressure=-52.5psf:
Deck: APA rated,7/16 CAT,0.4IS in„Exposure 1,05B sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Joints: Min.4-inch wide strips of Elastoflex SA-V over all OSB joints
Base Ply: Polystick MTS Plus,self-adhered.
Underlayment:Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FR),Polyflex SA P,Polyflex SA P FR,Polystick TU Max,Polystick
TU P or Polystick TU Plus,self-adhered.
42 Maximum Design Pressure=-90psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: None
Base Ply: (Optional)Polystick MTS Plus,self-adhered.
Underlayment:Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FR),Polyflex 5A P.Polyflex SA P FR,Polystick TU Max,Polystick
TU P or Polystick TU Plus,self-adhered.
#3 Maximum Design Pressure=-97.5 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: PG100 or ASTM D41
Base Ply: (Optional)Polystick MTS Plus,self-adhered.
Underlayment: Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FR),Polyflex SA P,Polyflex SA P FR,Polystick TU Max,Polystick
TU P or Polystick TU Plus,self-adhered and back-nailed within the selvedge-edge side laps using 12 ga.x 13:"ring shank nails
through 32 ga.,1-5/8"diameter tin caps spaced 12-inch o.c.
#4 Maximum Design Pressure=-105psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: WB-3000
Base Ply: (Optional)Polystick MTS Plus,self-adhered,
Underlayment: Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FR),Polyflex SA P.Polyflex SA P FR,Polystick TU Max,Polystick
TU P or Polystick TU Plus,self-adhered and back-nailed within the selvedge-edge side laps using 12 ga.x IX"ring shank nails
through 32 ga.,1-5/8"diameter tin caps spaced 12-inch o.c.
#5 Maximum Design Pressure=-135 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: (Optional)PG100 or ASTM D41
Base Ply: (Optional)Polystick MTS Plus,self-adhered.
Joints: Min.4-inch wide strips of Elastaflex SA-V over all plywood joints.
Underlayment: Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-ARP Cap Sheet(FR),Polyflex SA P.Polyflex SA P FR,Polystick TU Max,Polystick
TU P or Polystick TU Plus,self-adhered.
#6 Maximum Design Pressure=-315 psf:
Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: PG100 or ASTM D41
Base Ply: (Optional)Polystick MTS Plus,self-adhered,
Underlayment: HydraGuard Tile Pro, Mule-Elide SA-APP Cap Sheet, Mule-Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR,
Polystick TU Max,Polystick TU P or Polystick TU Plus,self-adhered.
#7 Maximum Design Pressure=-622.5psf:
Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: PG100 or ASTM D41
Underlayment: Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied.
NEMO ETC,LLC. Evaluation Report P12060.02.99-R25
Cerrr(irate of Authorization#32455 0 EDITION(2017)FBC NON-HVHZ EVALUATION FL5259-1129
Polyglass Roof Underlayments,(954)233-1230 Revision 25:1 0/1 412 0 113
Page 6 of 16
ONEMOletc.
#8 Maximum Design P ressu re=-30.0 psf*:
Deck: Min.15/32-inch OSB to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase or Mule-Hide Nail Base(poly-film top surface)
Fasteners: 11 ga.x 1.25-inch long x 1-inch head diameter round metal cap nails
Spacing: 6-inch o.c.at the 3-inch wide side laps and 6-inch o.c.at two(2)equally spaced staggered center rows.
Base Ply: (Optional)Polystick MTS Plus,self-adhered.
Underlayment:Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FR),Polyflex SA P,Polyflex 5A P FR,Polystick TU Max,Polystick
TU P or Polystick TU Plus,self-adhered.
#9 Maximum Design Pressure=-37.5 psf*:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction,
Base Sheet; Elastobase or Mule-Hide Nail Base(poly-film top surface)
Fasteners: 11 ga.x 1.2S-inch long x 1-inch head diameter round metal cap nails
Spacing; 6-inch❑.c.at the 3-inch wide side laps and 6-inch O.C.at two(2)equally spaced staggered center rows.
Base Ply: (Optional)Polystick MTS Plus,self-adhered.
Underlayment:Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FR),Polyflex SA P,Polyflex 5A P FR,Polystick TU Max,Polystick
TU P or Polystick TU Plus,self-adhered.
#10 Maximum Design Pressure=-37.5psf*:
Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: One(1)or two(2)layers ASTM D226,Type 11 felt
Fasteners: 11 ga.x 1.25-inch long x 1-inch head diameter round metal cap nails
Spacing; 6-inch o.c.at the 3-inch wide side laps and 12-inch o.c.at two(2)equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex 56 G,applied in full mopping of hot asphalt.
#11 Maximum Design Pressure=-45psf*:
Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: 0ne(1)layer ASTM D226,Type II felt
Fasteners: 11 ga.x 1.25-inch x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps
Spacing: 4-inch o.c.at the 2-inch wide side laps and 4-inch o.c.at two(2)equally spaced staggered center rows.
Base Ply: (Optional,for use with self-adhering underlayment only)Polystick MTS Plus,self-adhered.
Underlayment: Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FR),Polyflex SA P,Polyflex SA P FR,Polystick TU Max,Polystick
TU P or Polystick TU Plus,self-adhered or Elastoflex G TU,applied in full mopping of hot asphalt.
#12 Maximum Design_Pressure=-45 psf*:
Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Two(2)layers ASTM 0226,Type II felt
Fasteners: 11 ga.x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps
Spacing: 9-inch o.c.at the 2-inch wide side laps and 9-inch o.c.at two(2)equally spaced staggered center rows.
Base Ply: (Optional,for use with self-adhering underlayment only)Polystick MTS Plus,self-adhered.
Underlayment: Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FR),Polyflex 5A P,Polyflex SA P FR,Polystick TU Max,Polystick
TU P or Polystick TU Plus,self-adhered or Elastoflex G TU or Elastoflex 56 G,applied in full mopping of hot asphalt,
#13 Maximum Design Pressure=-45 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction,
Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap)
Fasteners: Simplex MAxX Cap Fasteners
Spacing: 9-inch o.c.at the 2-inch wide side laps and 18-inch o.c.at two(2)equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex 56 G,applied in full mopping of hat asphalt or Polyflex G,torch-applied.
#14 Maximum Design Pressure=-45.0 psf:
Deck: APA rated,7/16 CAT,0.418 in.,Exposure 1,05B sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase or Mule-Hide Nail Base(poly-film top surface)
Fasteners: 12 ga.annular ring shank nails with 1-5/8"diameter tin caps
Spacing: 6-inch o.c.at the 3-inch wide side laps and 5-inch o.c.at four(4)equally spaced staggered center rows.
Base Ply: (Optional)Polystick MTS Plus,self-adhered.
Underlayment:Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FR),Polyflex 5A P,Polyflex SA P FR,Polystick TU Max,Polystick
TU P or Polystick TU Plus,self-adhered.
NEMO ETC,LLC. Evaluation Report P12060.02.09-825
Certificate o(Authoriration#32455 0 EDITION(2017)FBC NON-HVH7 EVALUATION FL5259-R29
Paiyglass Roof Underlayments;(954)233-1230 Revision 25:10/14/2019
Page 7 of 16
ONEMOletc.
#15 Maximum Design Pressure=-45.0 psf:
Deck: APA rated,7/16 CAT,0.418 in.,Exposure 1,OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase(sand top surface)
Fasteners: 12 ga.annular ring shank nails with 1-5/8"dia meter tin caps
Spacing: 6-inch o.c.at the 3-inch wide side laps and 6-inch o.c.at four(4)equally spaced staggered center rows.
Underlayment:Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt.
#16 Maximum Design Pressure=-45.0 osf:
Deck: APA rated,7/16 CAT,0.418 in.,Exposure 1,OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase or Polyglass Base
Fasteners: 12 ga.annular ring shank nails with 1-5/8"diameter tin caps
Spacing: 6-inch o.c.at the 3-inch wide side laps and 6-inch o.c.at four(4)equally spaced staggered center rows.
Underlayment: Po[yflex G,torch-applied.
#17 Maximum Design Pressure=-52.5 psf;
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap)
Fasteners: Simplex MAXX Cap Fasteners
spacing: 9-inch o.c,at the 2-inch wide side laps and 12-inch o.c.at two(2)equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex 56 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied.
#18 Maximum Design Pressure=-52.5 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase or Mule-Hide Nail Base(poly-film top surface)
Fasteners: Simplex Original Cap Nails
Spacing: 6-inch o.c.at the 3-inch wide side laps and 6-inch o.c,at four(4)equally spaced staggered center rows.
Base Ply: (optional)Polystick MTS Plus,self-adhered.
Underlayment: Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FR),Polyflex SA P,Pclyflex SA P FR,Polystick TU Max,Polystick
TU P or PoiystickTU Plus,self-adhered.
#19 Maximum Design Pressure=-52.5 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-fifm surface for torch-applied cap)
Fasteners: Simplex Original Cap Nails
Spacing: 6-inch o.c.at the 3-inch wide side laps and 6-inch o.c.at four(4)equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex$6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied.
#20 Maximum Design Pressure=-60 psf:
Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap)
Fasteners: 11 ga.x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps
Spacing: 8-inch o.c.at the 4-inch wide side laps and 8-inch o.c.at three(3)equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied.
#21 Maximum Design Pressure=-60 psf:
Deck: Mim 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap)
Fasteners: OMG#12 standard Roofgrip with CMG Flat Bottom Metal Plates
Spacing: 12-inch o.c.at the 4-inch wide side laps and 12-inch o.c.at two(2)equally spaced staggered center rows.
Underlayment: Eiastoflex G TU or Elastoflex 56 G,applied in full mopping of hot asphalt or Po[yfex G,torch-applied.
NEM❑ETC,LLc. Evaluation Report P12060.02.09-1125
Certificate of Authorization#32455 6""EDITION(2017)FBC NON•HVHI EVALUATION FL5259-R29
Polyglass Roof Underlayments;(954)233-1230 Revision 25:10/14/2019
Page 8 of 16
ONEMOletc.
#22 Maximum Design Pressure=-60.0 sf:
Deck: APA rated,7/16 CAT,0.418 in.,Exposure 1,OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastabase or Mule-Hide Nail Base(poly-film top surface)
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 8-inch o.c.at the 3-inch wide side laps and 8-inch o.c.at three(3)equally spaced staggered center rows.
Primer: PG100 or AST D41 primer applied to stress plates.
Base Ply: (Optional)Polystick MTS Plus,self-adhered.
Underlayment: Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FR),Polyflex SA P,Pofyfiex SA P FR,Polystick TU Max,Polystick
TU P or Polystick TU Plus,self-adhered.
#23 Maximum Design Pressure=-60.0 sf:
Deck: APA rated,7/16 CAT,0.418 in.,Exposure 1,OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet. Elastobase(sand top surface)
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 8-inch a.c.at the 3-inch wide side laps and 8-inch o.c.at three(3)equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G.applied in full mopping of hot asphalt.
#24 Maximum Design Pressure=-60.0 psf:
Deck: APA rated,7/16 CAT,0.418 in.,Exposure 1,OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase or Polyglass Base
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 8-inch o.c.at the 3-inch wide side laps and 8-inch o.c.at three(3)equally spaced staggered center rows.
Underlayment: Polyflex G,torch-applied.
#25 Maximum Design Pressure=-67.5 sf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Poiyglass G2 Base or Polyglass Base(requires use of torch-applied underlayment)
Fasteners: 12 ga.x 1.25-inch long 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps
Spacing: 8-inch o.c.at the 4-inch wide side laps and 8-inch o.c.at four(4)equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G,applied in full mapping of hot asphalt or torch-applied or Polyflex G,torch-applied.
#26 Maximum Design Pressure=-67.5 sf:
Deck: APA rated,19/32 CAT,0.578 in.,Exposure 1,OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase or Mule-Hide Nail Base(poly-film top surface)
Fasteners: TRUFAST Versa-Fast Fasteners&Plates with two(2)screws per plate installed 180'into the holes of the plate, parallel to
the width direction of the sheet.
Spacing: 12-inch o.c.at the 4-inch wide side laps and 12-inch o.c.at two(2)equally spaced staggered center rows.
Primer: (Optional)PG100 or ASTM D41 primer applied to stress plates.
Base Ply: (Optional)Polystick MTS Plus,self-adhered.
Underlayment;Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FR),Polyflex SA P,Polyflex 5A P FR,Polystick TU Max,Polystick
TU P or Polystick TU Plus,self-adhered,
#27 Maximum Design Pressure=-67.5 sf:
Deck: APA rated,19/32 CAT,0.578 in.,Exposure 1,OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastabase(sand top surface)
Fasteners: TRUFAST Versa-Fast Fasteners&Plates with two(2)screws per plate installed 180°into the holes of the plate,parallel to
the width direction of the sheet.
Spacing: 12-inch o.c.at the 4-inch wide side laps and 12-inch o.c.at two(2)equally spaced staggered center rows.
Underlayment: Elastoflex G TiJ or Elastoflex S6 G,applied in full mopping of hot asphalt.
NEnno ETC,LLC. Evaluation Report P12060.02.09-R25
Certificate of Authorization N32455 fin'EDITION(2017)FBC NON-HVH2 EVALUATION FL5259-1129
Polyglass Roof Underlaymerrts;(954)233-1230 Revision 25:10/14/2019
Page 9 of 16
ONEMOletc.
#28 Maximum Design Pressure=-67.5psf:
Deck: APA rated,19/32 GAT,0.578 in.,Exposure 1,GSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase or Polyglass Base
Fasteners: TRU FAST Versa-Fast Fasteners&Plates with two(2)screws per plate installed 180'into the holes of the plate,parallel to
the width direction of the sheet.
Spacing: 12-inch o.c.at the flinch wide side laps and 12-inch o.c.at two(2)equally spaced staggered center rows.
Underlayment;Polyflex G,torch-applied.
#29 Maximum_ Design Pressure=-75 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Polyglass G2 Base or Polyglass Base(requires use of torch-applied underlayment)
Fasteners: Dekfast#14 with Dekfast Hex plates,OMG#14 HD with CMG 3"Galvalume Steel Plates,OMG Roofgrip#14 with OMG Flat
Bottom Plates(AccuTrac),Trufast HD with Trufast 3-inch Insulation Plates or Simplex MAXX Cap Fasteners
Spacing: 10-inch o.c.at the 4-inch wide side laps and 10-inch o.c.at three(3)equally spaced staggered center rows.
Underlayment:Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt or torch-applied or Polyflex G,torch-applied.
#30 Maximum Design Pressure=-90psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction,
Base Sheet; Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap)
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 6-inch o.c.at the 2-inch wide side laps and 6-inch o.c.at two(2)equally spaced staggered center rows.
Underlayment:Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied.
#31 Maximum Design Pressure=-90 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap)
Fasteners: OMG#12 Standard Roofgrip or CMG#14 Heavy Duty with OMG 3"Round Metal Plates or OMG Flat Bottom Metal Plates
Spacing: 6-inch o.c.at the 4-inch wide side laps and 6-inch o.c.at three(3)equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied.
#32 Maximum Design Pressure=-90 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase(sanded top surface)
Fasteners: Trufast#12 DP or Trufast#14 HD with Trufast 3"Metal Insulation Plates
Spacing: 6-inch o.c.at the 4-inch wide side laps and 6-inch o.c.at three(3)equally spaced staggered center rows.
Underlayment:Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt.
#33 Maximum Design Pressure=-90 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Polyglass G2 Base or Polyglass Base(requires use of torch-applied underlayment)
Fasteners: Dekfast#14 with Dekfast Hex plates,OMG#14 HD with OMG 3"Galvalume Steel Plates,OMG Roofgrip#14 with OMG Flat
Bottom Plates(AccuTrac),Trufast HD with Trufast 3-inch Insulation Plates or Simplex MAXX Cap Fasteners
Spacing: 9-inch o.c.at the 4-inch wide side laps and 9-inch o.c.at four(4)equally spaced staggered center rows.
Underlayment:Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt or torch-applied or Polyflex G,torch-applied.
#34 Maximum Design Pressure=-90.0 sf:
Deck: APA rated,7/16 CAT,0.418 in.,Exposure 1,OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase or Mule-Hide Nail Base(poly-film top surface)
Fasteners: TRU FAST Versa-Fast Fasteners&Plates with two(2)screws per plate installed 180°into the holes of the plate,parallel to
the width-direction of the sheet
Spacing: 9-inch o.c.at the 2-inch wide side laps and 12-inch o.c.at two(2)equally spaced staggered center rows.
Primer: PG100 or ASTM D41 primer applied to stress plates.
Base Ply: (0ptiona1)Polystick MTS Plus,self-adhered.
Underlayment: Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FIR),Polyflex SA P.Polyflex SA P FIR,Polystick TU Max,Polystick
TU P or Polystick TU Plus,self-adhered.
NEMO ETC,LLC. Evaluation Report P12060.02.09-R25
Certificate of AuthorizQrdan#32455 0 EDITION(2017)FBC NON•HVHI EVALUATION FL5259-R29
Polyglass Roof Underlayments;(954)233-1230 Revision 25:10/14/2019
Page 10 of 16
ONEMOletc.
#35 Maximum Design Pressure--90.0 psf:
Deck: APA rated,7/16 CAT,0.418 in.,Exposure 1,DSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase(sand top surface)
Fasteners: TRUFAST Versa-Fast Fasteners&Plates with two(2)screws per plate installed 180'into the holes of the plate,parallel to
the width-direction of the sheet
Spacing: 9-inch o.c.at the 2-inch wide side laps and 12-inch o.c.at two(2)equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt.
#36 Maximum Design Pressure=-90.0psf:
Deck: APA rated,7/16 CAT,0.418 in.,Exposure 1,DSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase or Polyglass Base
Fasteners: TRUFAST Versa-Fast Fasteners&Plates with two(2)screws per plate installed 180'into the holes of the plate,parallel to
the width-direction of the sheet
Spacing: 9-inch o.c.at the 2-inch wide side laps and 12-inch o.c.at two(2)equally spaced staggered center rows.
Underlayment: Polyflex G,torch-applied.
#37 Maximum Design Pressure=-97.5 psf:
Deck: Min,19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase or Mule-Hide Nail Base(poly-film top surface)
Fasteners; 11 ga.x 1.25-inch x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps
Spacing: 4-inch o.c.at the 4-inch wide side laps and 4-inch❑.c.at four(4)equally spaced staggered center rows.
Base Ply: (0ptiona1)Palystick MTS Plus,self-adhered.
Underlayment:Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FR),Polyflex SA P,Polyflex SA P FR,Polystick TU Max,Polystick
TU P or Polystick TU Plus,self-adhered.
#38 Maximum Design Pressure=-97.5 psf:
Deck: APA rated,19/32 CAT,0.578 in.,Exposure 1,DSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase or Mule-Hide Nail Base(poly-film top surface)
Fasteners: Simplex MAXX Cap Fasteners
Spacing; 6-inch o.c.at the 4-inch wide side laps and 6-inch o.c.at four(4)equally spaced staggered center rows.
Primer: PG100 or ASTM 041 primer applied to stress plates.
Base Ply: (0ptiona1)Polystick MTS Plus,self-adhered.
Underlayment: Mule-Hide SA-APP Cap Sheet,Mule-hide SA-APP Cap Sheet(FIR),Polyflex SA P,Polyflex SA P FR,Polystick TU Max,Polystick
TU P or Polystick TU Plus,self-adhered.
#39 Maximum Design Pressure=-97.5psf:
Deck: APA rated,19/32 CAT,0.578 in.,Exposure 1,DSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase(sand tap surface)
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 6-inch o.c.at the 4-inch wide side laps and 6-inch o.c.at four(4)equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt.
#40 Maximum Design Pressure=-97.5psf:
Deck: APA rated,19/32 CAT,0.578 in.,Exposure 1,OS sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase or Polyglass Base
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 6-inch o.c.at the 4-inch wide side laps and 6-inch o.c.at four(4)equally spaced staggered center rows.
Underlayment: Polyflex G,torch-applied.
#41 Maximum Design Pressure=-105 psf.-
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap)
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 6-inch o.c.at the 2-inch wide side laps and 6-inch o.c.at three(3)equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex 56 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied.
NEMO ETC,LLC. Evaluation Report P12050.02.09-1125
Certlficote of Authorization#32455 6"'EDITION(2017)FBC NON-HVHI EVALUATION FL5259-1129
Polyglass Roof Underlayments;(954)233-1230 Revision 25:10/14/2019
Page 11 of 15
ONEM01eft.
#42 Maximum Design Pressure=-105.0 psf:
Deck: APA rated,7/16 CAT,0.418 in.,Exposure 1,OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase or Mule-Hide Mail Base(poly-film top surface)
Fasteners: TRUFAST Versa-Fast Fasteners&Plates with two(2)screws per plate installed 180'into the holes of the plate,parallel to
the width-direction of the sheet
Spacing: 6-inch o.c.at the 4-inch wide side laps and 6-inch o.c.at three(3)equally spaced staggered center rows.
Primer: PG100 or ASTM D41 primer applied to stress plates.
Base Ply: (Optional)Polystick MTS Plus,self-adhered.
Underlayment: Mule-Hide SA-APP Cap Sheet,Mule-tilde SA-APP Cap Sheet(FIR),Polyflex SA P.Polyflex SA P FIR,Polystick TU Max,Polystick
TU P or Polystick TU Plus,self-adhered.
#43 Maximum Design Pressure=-105.0 psf:
Deck: APR rated,7/16 CAT,1418 in.,Exposure 1,OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase(sand top surface)
Fasteners: TRUFAST Versa-Fast Fasteners&Plates with two(2)screws per plate installed 180'into the holes of the plate,parallel to
the width-direction of the sheet
Spacing: 6-inch o.c.at the 4-inch wide side laps and 6-inch o.c.at three(3)equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt.
#44 Maximum Design Pressure=-105.0 psf:
Deck: APA rated,7/16 CAT,0.418 in.,Exposure 1,OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase or Polyglass Base
Fasteners: TRUFAST Versa-Fast Fasteners&Plates with two(2)screws per plate installed 180°into the holes of the plate,parallel to
the width-direction of the sheet
Spacing: 6-inch o.c.at the 4-inch wide side laps and 6-inch o.c.at three(3)equally spaced staggered center rows.
Underlayment: Polyflex G,torch-applied.
#45 Maximum Design Pressure=-112.5 psf:
Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase or Mule-Hide Nail Base(poly-film top surface)
Fasteners: 11 ga.x 1.25-inch x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps
Spacing: 6-inch o.c.at the 4-inch wide side laps and 6-inch o.c.at four(4)equally spaced staggered center rows.
Primer: PG100 or ASTM D41 primer at all tin-caps
Base Ply_ Polystick MTS Plus,self-adhered
Underlayment: Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FIR),Polyflex SA P,Polyflex SA P FR.Polystick TU Max,Polystick
TU P or Polystick TU Plus,self-adhered.
#46 Maximum Design Pressure=-120 1psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap)
Fasteners: OMG#12 Standard Roofgrip or OMG#14 Heavy Duty with OMG 3"Round Metal Plates or OMG Flat Bottom Metal Plates
Spacing: 6-inch o.c.at the 4-inch wide side laps and 6-inch o.c.at five(5)equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied.
#47 _Maximum Design Pressure=-120 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority}laving Jurisdiction.
Base Sheet: Elastobase(sanded top surface)
Fasteners: Trufast#12 DP or Trufast#14 HD with Trufast 3"Metal Insulation Plates
Spacing: 6-inch o.c.at the 4-inch wide side laps and 6-inch o.c.at five(5)equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex 56 G,applied in full mopping of hot asphalt.
NEMO ETC,LLC. Evaluation Report P12060.02.09-1125
Certificate Of Authorization#32455 6-EDITION(2011)FBC NON-HVHZ EVALUATION FL5259-R29
Polyglass Roof underlaymerds;(954)233-1230 Revision 25:10/14/2019
Page 12 of 16
ONEMOletc.
#48 Maximum Desijzn Pressure=-127.5 sf:
Deck: APA rated,19/32 CAT,0.578 in.,Exposure 1,05B sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase or Mule-Hide Nail Base(poly-film top surface)
Fasteners: TRUFAST Versa-Fast Fasteners&Plates with one(1)screw per plate,in the center hole.
Spacing: 9-inch o.c.at the 4-inch wide side laps and 9-inch o.c.at four(4)equally spaced staggered center rows.
Primer: PG100 or ASTM D41 primer applied to stress plates.
Base Ply: (Optional)Polystick NITS Plus,self-adhered.
Underlayment: Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FIR),Polyflex 5A P,Polyflex SA P FIR,Polystick TU Max,Polystick
TU P or Polystick TU Plus,self-adhered.
#49 Maximum Design Pressure=-127.5 O:
❑e& APA rated,19/32 CAT,0.578 in.,Exposure 1,05B sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase(sand top surface)
Fasteners: TRUFAST Versa-Fast Fasteners&Plates with one(1)screw per plate,in the center hole.
Spacing: 9-inch o.c.at the 4-inch wide side laps and 9-inch o.c.at four(4)equally spaced staggered center rows.
Underlayment:Elastoflex G TU or Elastoflex 56 G,applied in full mopping of hot asphalt.
#50 Maximum Design Pressure=-127.5 sf:
Deck: APA rated,19/32 CAT,0.578 in.,Exposure 1,OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase or Polyglass Base
Fasteners: TRUFAST Versa-Fast Fasteners&Plates with one(1)screw per plate,in the center hole.
Spacing: 9-inch o.c.at the 4-inch wide side laps and 9-inch o.c.at four(4)equally spaced staggered center rows.
Underlayment:Polyflex G,torch-applied.
5.6.1.1 All other direct-deck, adhered Polyglass underlayment systems beneath foam-an tile systems carry a Maximum Design
Pressure of-45 psf.
5.6.1.2 For mechanically attached Base Sheet, the maximum design pressure for the selected assembly shall meet or exceed that
required under FRSA/TRI April 2012(04-12),Appendix A,Table 1A.
Alternatively, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure
determined in accordance with FBC 1609. In this case, zones 2 and 3 shall employ an attachment density designed by a
qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WD1, FM Loss
Prevention Data Sheet 1-29 and Roofing Application Standard RA5 117, Assemblies marked with an asterisk* carry the
limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29(January 2016)for Zone 2/3 enhancements.
5.7 Exposure Limitations:
TABLE 3: ExPOsURE LIMITATIONS
Underlayment Maximum Exposure(days)
Elastoflex G TU,HydraGuard Dual Pro,HydraGuard Tile Pro,Polystick MT5 Plus,Polystick TU 180
Max,Polystick TU P or Polystick TU Plus
Polystick IR-xe or Polystick MU-X 90
Elastobase,Elastobase P,Polyglass G2 Base or Polyglass Base 30
180
Elastoflex 56 G,Elastoflex 56 G FIR,Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet (for adhesive-set tile)
(FIR),Polyflex G,Polyflex G FIR,Polyflex SA P or Polyflex SA P FIR UNLIMITED
(for mechanically fastened roof
prepared roof covers)
5.8 Polystick MU-X has been found through comparative testing to have a lesser coefficient of friction than ASTM D226 roofing
felt in a dry condition, tested at standard laboratory conditions. Agreement between purchaser and seller, as set forth in
Section 4.3,Nate 1 of ASTM D1970-15,should be established as to slip resistance.
Nsnno ETC,LLc. Evaluation Report P12060.02.09-R25
CerrificureofAuthorrrdrion#32455 6'EDITION(2017)FBC NON-HVH2 EVALUATION FL5259-R29
Polyglass Roof U nd erlayme nts;(954)233-1230 Revision 25:10/14/2019
Page 13 of 16
5.9 Tile Slippaige Limitations FRSAITRI April 2012(04-12)) ONEMOJetc.
When loading roof tiles on the underlayment in direct-deck tile assemblies,the maximum roof slope shall be as follows. These
slope limitations can only be exceeded by using battens during loading of the roof tiles.
TAaLE 2: TILE SLIPPAGE LimrrATioNs FOR DIRECT-DECK TILE INSTALLATIONS
Underlayment Tile Profile Staging Method Maximum Slope
Elastoflex G TU Flat 10-t1le stack 7:12
Lugged 8-tile stack(6 over 2) 6:12
Elastoflex 56 G or 56 G FR Flat or Lugged 6-tile stack(4 over 2) 4:12
HydraGuard Tile Pro Flat or Lugged 6-tile stack(4 over 2) 7:12
Poly-flex G or G FR Flat or Lugged 6-tile stack(4 over 2) 4:12
Polyflex 5A P or 5A P FR Flat or Lugged 6-tile stack(4 over 2) 4:12
Polystick MTS Plus Flat 6-tile stack(4 over 2) 5:12
Lugged 6-tile stack(4 over 2) 4:12
Flat 6-tile stack(4 over 2)or 10-tile stack 7:12
Polystick TU Max Lugged 6-tile stack(4 over 2) 7:12
Lugged 10-tile stack 6:12
Poiystick TU P Flat 6-tile stack(4 over 2) 6:12
Lugged 6-tile stack(4 over 2) 4:12
Polystick TU Plus Flat or Lugged 6-tile stack(4 over 2) 7.12
Flat or Lugged 10-ti€e stack 6:12
fi. INSTALLATION:
6.1 Polyglass Roof Underlayments shall be installed in accordance with Polyglass published installation requirements subject to the
Limitations set forth in Section 5 herein and the specifics noted below.
6.2 Re-fasten any loose decking panels,and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust
and debris prior to application,and prime the substrate(if applicable).
6.3 Elastobase,Elastobase P or Mule-Hide Nail Base:
6.3.1 Non-Tile Applications:
Shall be installed in compliance with the codified requirements for ASTM❑226,Type II underlayment in FBC Table 1507.1.1 for
the type of prepared roof covering to be installed and Polyglass published requirements.
Elastobase, Elastobase P or Mule-Hide Nail Base may be covered with a layer of Polystick, Polyflex SAP, PolyfIex SA P FR,Mule-
Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR), self-adhered, Elastoflex G TU, Elastoflex S6 G or Elastoflex 56 G FR in hot
asphalt or Polyflex G or Polyflex G FR,torch applied. Roof cover limitations are those are those associated with the top-layer
underlayment,as set forth in Table 1.
6.3.2 Tile Applications:
Elastobase, Elastobase P or Mule-Hide Nail Base are limited to use as a mechanically attached base sheet in the "Two Ply
System"from FRSA/TRI April 2012(04-12). Reference is made to Table 1 and Section 5.6.1 herein,coupled with FRSA/TRI April
2012(04-12)Installation Manual.
NEMO ETC,LLC. Evaluation Report P12060.02.49-R25
certificate ofAuthoriration#32455 6-EDITION(2017)FBC NON-HVHI EVALUATION FL5259-R29
Polyglass Roof Underlayments;(954)233-1230 Revision 25:10/14/2019
Page 14 of 16
ONEMOjetc.
6.4 [HydraGuard dual Pro.HydraGuard Tile Pro,Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FR),Polyflex SA P,
Polyflex SA P FR,Polystick IR-Xe,Polystick MTS Plus,Polystick MU-X,Polystick TU Max,Polystick TU P or Polystick TU Plus:
6.4.1 General:
Ail seal-lap seams(selvage laps)must be firmly rolled with a in
accordance with Polyglass requirements to ensure full contact ,.
and adhesion. For HydraGuard Dual Pro and HydraGuard Tile '
Pro, align the edge of the top sheet to the end of the glue ".. .
pattern(the sheet will overlap the fabric).
View of Ove lap Seam of HydraGuard Dual Pro and HydraGuard Tile Pro
6.4.2 Non-Tile Applications:
Shall be installed in compliance with the codified requirements for ASTM D1970(except Polystick TU P) underlayment in FBC
Table 1507.1.1 for the type of prepared roof covering to be installed and Polyglass published requirements.
6.4.3 Tile Applications texcludes HydraGuard Dual Pro, Polystick!R-Xe and Polystick MU-X
Shall be installed in compliance with the requirements far Self-Adhered Membrane set forth in FRSA/TRI April 2012(04-12)and
Polyglass published requirements.
For mechanically fastened tile roofing over 2-ply system, consisting of Base Sheet and self-adhering top sheet(s), Base Sheet
fastening shall be not less than FRSA/TRI April 2012(04-12),Table 1.
For adhesive-set tile applications,refer to Section 5.6.1 herein.
6.4.4 Multi-Ply Underla ment Systems:
Polystick MTS Plus followed by HydraGuard Tile Pro, Polyflex 5A P, Polystick MTS Plus, Polystick MU-X, Polystick TU Max,
Polystick TU P or Polystick TU Plus is allowable for use under mechanically attached prepared roof systems. Limits of use are
those associated with the top-layer material. This is not a requirement, but is allowable if a 2-ply underlayment system is
desired.
Polystick MTS Plus followed by HydraGuard Tile Pro, Polyflex SA P, Polystick TU Max, Polystick TU P or Polystick TU Plus is
allowable for use under adhesive-set the systems. Limits of use are those associated with the top-layer material. This is not a
requirement, but is allowable if a 2-ply underlayment system is desired.
6.5 Elastoflex G TU,Elastoflex S6 G or Elastoflex S6 G FR:
6.5.1 Elastoflex G TU,ElastoflexS6 G or ElastoflexS6 G FR shall be installed in compliance with current Polyglass published installation
requirements. For use in tile applications:
Elastoflex G TU is for use as an alternate to"Mineral Surface Roll Roofing"(ASTM D6380,Class M)in the"Single Ply System"
from FRSA/TRI April 2012(04-12) beneath mechanically fastened tile roof systems or the Hot Asphalt applied "Cap Sheet"
in the"Two Ply System"from FRSA/TRI April 2012(04-12)beneath mechanically fastened or adhered tile roof systems.
Elastoflex 56 G is for use as an alternate to"Mineral Surface Roll Roofing"(ASTM D6380,Class M)in the"Single Ply System"
from FRSA/TRI April 2012(04-12) beneath mechanically fastened tile roof systems or the Hot Asphalt applied "Cap Sheet"
in the"Two Ply System"from FRSA/TR!April 2012(04-12)beneath mechanically fastened or adhered tile roof systems.
+� Elastoflex 56 G FR is for use as an alternate to "Mineral Surface Roll Roofing" (ASTM D6380, Class M) in the "Single Ply
System"from FRSA/TRI April 2012(04-12)beneath mechanically fastened tile roof systems or the Hot Asphalt applied"Cap
Sheet"in the"Two Ply System"from FRSA/TRI April 2012(04-12)beneath mechanically fastened tile roof systems.
NEAAO ETC,LLC. Evaluation Report P12060.02,09-1125
Certificate of Authorization#32455 5TM EDITION(2017)FBC NON-HVH2 EVALUATION FL5259-R29
Polyglass Roof Underlayments;(954)233-1230 Revision 25:10/14/2019
Page 15 of 16
ONEMOjetc.
6.5.2 For hot-asphalt-applications,Elastoflex G TU,Elastoflex 56 G or Elastoflex S6 G FR shall be fully asphalt-applied to the substrates
noted in Table 2. Side laps shall be minimum 3-inch and end-laps minimum 6-inch wide, off-set minimum 3 feet from course
to course. Side and end laps shall be fully adhered in a complete mopping of hot asphalt with asphalt extending approximately
3/8-inch beyond the lap edge.
6.6 Polyflex G or PolyRex G FR:
6.6.1 Polyflex G or Polyflex G FR shall be installed in compliance with current Polyglass published installation requirements. For use
in tile applications:
+� Polyflex G is for use as an alternate to the Heat Applied"Cap Sheet"in the"Two Ply System"from FRSA/TRI April 2012(04-
12)beneath mechanically fastened or adhered tile roof systems(Refer to Table 2 for base sheet options).
Polyflex G FR is for use as an alternate to the Heat Applied "Cap Sheet" in the "Two Ply System"from FRSA/TRI April 2012
(04-12)beneath mechanically fastened the roof systems(Refer to Table 2 for base sheet options).
6.6.2 Polyflex G or Polyflex G FR shall be fully torch-applied to the substrates noted in Table 2. Side laps shall be minimum 3-inch and
end-laps minimum 6-inch wide,off-set minimum 3 feet from course to course. Side and end laps shall be fully heat-welded and
inspected to ensure minimum 3/8-inch flow of modified compound beyond the lap edge.
6.7 Tile Staging:
6.7.1 Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the underlayment. Refer to Table 2
herein,and Polyglass published requirements for the staging.
6.7.2 Battens and/or Counter-battens,as required by the tile manufacturer and FRSA/TRI April 2012(04-12)must be used on all roof
slopes greater than 7:12. Precautions should be taken as needed, such as the use of battens or nail-boards,to prevent tile
sliding and/or damage to the underlayment during the IoadIng process.
7. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official orAutharity Having Jurisdiction in orderto properly evaluate the installation of this product.
is. MANUFACTURING PLANTS:
Contact the noted QA agency for information on product locations covered for F.A.C. 61G20-3 QA requirements. Refer to
Section 4 herein for product&production locations having met codified physical properties specifications.
9. QUALITY ASSURANCE ENTITY:
UL,LLC—QUA9625;(314)578-3406;k.chancellor@us.ul.com
-END OF EVALUATION REPORT-
NEMO ETC,LLC• Evaluation Report P12060.42.09-R25
Certrfcateof Authorization#32455 V"EDIT10N(20171 FBC N0N-HVHI EVALUATION FL5259-R29
Polyglass Roof Underlayments;(954)233-1230 Revision 25:10/14/2019
Page 16 of 16