HomeMy WebLinkAboutBlower Door Test FormDate: -7 1 1 e6 l t
Contractor: C o
Job Address: LkS
Construction:
Planning & Development Services
Building & Code Regulation Division
2300 Virginia Ave, Rm 201
Fort Pierce, FL 34982
Phone:772-462-2165 Fax:772-462-6443
BLOWER DOOR TEST FORM
House Infiltration Test Certification
Prescriptive and Performance Method
1 Per mit#: ! TO-2- o 3
( �O New Construction — Complete ( ) Existing —After Addition
House infiltration Test Results SLC Climate tone 2
CFM,JSO) = T Dates t� a
Volume
ACH (SO) = CFM (SO) x 60 / Volume = d CMechanical Ventilation required less than 3 AC
Passing results must be & ACH (50) or less
FBC, Energy
The building or dwelling unlitshallbe tested and verified as having an air leakage rate of not exceeding 7 airchanges per
hour in Climate Zone 1, 2 and 3 air changes per hour in Climate,Zones 3 through 8. Testing shall be conducted with a
blower door at a pressure of 0.2 inches w. g. (50 Pascals). Testing shall be conducted by either individuals as defined in
Section 553.993(5) or (7), Florida Statutes or individuals licensed as forth in Section 489.105 (3)(f), (g) or (1) or an
approved third party. A written report of the results of the test shall be signed by the party conducting the test and
,provided to the code official. Testing shall be -performed at any time after creation of all penetrations of the building
thermal envelope.
FBC, Residential.
Where the air infiltration rate of a dwelling unit is less than 3 air changes per,hour when tested with a blower door at a
pressure of 0.2 inch w. c. (50 Pa) in.accordance with Section,R402,41.2 of the,Florida i3uilding.Code, Energy Conservation
the dwelling unit shall be provided with wholeriouse mechanical ventilation in accordance with Section M1507.3,
Testine Company r y tt -- �pay -' ` Address:l;<D° ill V, rComnName, .
I hereby certify that the above
License/Certification#: _f �-
nfiltration results demonstrate compliance with FBC Energy Conservation
p'b 11402 4,1.2 Climate Zone�2.,
t
�4 j
William Durden
From:
Phil Nisa Jr. <phil@nisair.com>
Sent:
Thursday, July 25, 2019 10:42 AM
To:
William Durden
Cc:
'Mario Arbucci'
Subject:
Coastal construction permit *1807-0413
Attachments:
2012IRCVentilationRequirements(2).pdf
William, Here is the information as requested in PDF form : The total AC space is 4231 and the home has 4 Bedrooms
requiring 90 CFM of makeup air per table M1507.3.3 Nisair has installed a 6" make up capable of 120 CFM with manual
volume
damper to adjust the CFM it is connected to the 5ton air handler that can produce up to 2000 CFM total. Please feel free
to contact me any questions or concerns.
Thank you,
Philip Nisa Jr
Sincerely,
4/18
1�11
AIR CONOMONING
Philip A. Nisa, Jr.
President
phil@nisair.com
www.nisair.com
(0) 772.466.8115 Ext. 203
(C) 772.260.2068
(F) 772.460.2578
Dave R onox
PREMIER DEALER-
Lli��l'i'i ..
Please Note: Florida has very broad public records laws. Most written communications to or from County officials regarding County business are public records
available to the public and media upon request. It is the policy of St. Lucie County that all County records shall be open for personal inspection, examination and I
or copying. Your e-mail communications will be subject to public disclosure unless an exemption applies to the communication. If you received this email in error,
please notify the sender by reply e-mail and delete all materials from all computers.