HomeMy WebLinkAboutCertification for Design Load CompliancePlanning & Development Services Department
Building & Code Regulations Division
2300 Virginia Avenue, Fort Pierce, FL 34982 — (772) 462-1553
Certification for Design Load Compliance
Project Name: ARBUCCI RESIDENCE
Project Address: LOT 39 WATERSONG
Permit #:
Occupancy Type: R-3 Construction Type: V
INSTRUCTIONS FOR USE:
o This certification must be completed, signed, and sealed by the design professional of record.
o Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following:
o New Residences (single or multi -family)
o Residential Addition
o Any accessory structure requiring a building permit
o Any non-residential structure.
* Note: Form not required for interior renovations provided that no exterior structural elements are affected and
certain minor building permits at the discretion of the local building official. Contact the # above for questions.
DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply)
1. DESIGN CODE: Florida 2017 Code Fifth Edition with 20 Supplements using ASCE 7-10
2. Structure Designed as (check one): X Enclosed Partially Enclosed Open
3. Risk Category: _I X II III IV Exposure Category: B C X D
4. Design Wind Velocity 170 mph X ASD LRFD End Zone Width: 3.0 ft
5. Mean Roof Height 39.0 ft Roof Pitch: 7 :12 Parapet: N/A ft
6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings):
Zone 1: 49.9 Zone 2: 86.6 Zone 3: 128.4 Zone 4: 53.2 Zone 5: 62•9 Garage: 50.2
7. Design Loads: Floor: 40 L.L. PSF Roof/Dead: 25 PSF Roof/Live: 30 Balcony: 40L.L PSF
Dock: N/A PSF Deck: PSF Stairs: 40 L.L. PSF Fence: PSF Railings: 200# �QPSF° t, °ate
8. Were Shear Walls Considered For Structure? X Yes Not Applicable Explain Why Not:
9. Is A Continuous Load Path Provided? X Yes Not Applicable Explain Why Not:
10. Design Soil Bearing Pressure: PSF Soil Test Reports Submitted? Yes
OP
DESIGN PROFESSIONAL CERTIFICATION STATEMENT:
I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to
comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie
County. I also certify that structural elements depicted on these plans provide adequate resistance to the design
forces specifierJ:
I JAMES BUSHOUSE P.E. #20311 C.A.#27565
'1 A' h
Date, and Seal
Revised 07/25/2014
Print Name Cert # & Co. Cert Auth.
JAMES BUSHOUSE INC
216 E MAGNOLIA STREET, ARCADIA, FL 34266
Company Name & Address
�� Copy