Loading...
HomeMy WebLinkAboutCertification for Design Load CompliancePlanning & Development Services Department Building & Code Regulations Division 2300 Virginia Avenue, Fort Pierce, FL 34982 — (772) 462-1553 Certification for Design Load Compliance Project Name: ARBUCCI RESIDENCE Project Address: LOT 39 WATERSONG Permit #: Occupancy Type: R-3 Construction Type: V INSTRUCTIONS FOR USE: o This certification must be completed, signed, and sealed by the design professional of record. o Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following: o New Residences (single or multi -family) o Residential Addition o Any accessory structure requiring a building permit o Any non-residential structure. * Note: Form not required for interior renovations provided that no exterior structural elements are affected and certain minor building permits at the discretion of the local building official. Contact the # above for questions. DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply) 1. DESIGN CODE: Florida 2017 Code Fifth Edition with 20 Supplements using ASCE 7-10 2. Structure Designed as (check one): X Enclosed Partially Enclosed Open 3. Risk Category: _I X II III IV Exposure Category: B C X D 4. Design Wind Velocity 170 mph X ASD LRFD End Zone Width: 3.0 ft 5. Mean Roof Height 39.0 ft Roof Pitch: 7 :12 Parapet: N/A ft 6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings): Zone 1: 49.9 Zone 2: 86.6 Zone 3: 128.4 Zone 4: 53.2 Zone 5: 62•9 Garage: 50.2 7. Design Loads: Floor: 40 L.L. PSF Roof/Dead: 25 PSF Roof/Live: 30 Balcony: 40L.L PSF Dock: N/A PSF Deck: PSF Stairs: 40 L.L. PSF Fence: PSF Railings: 200# �QPSF° t, °ate 8. Were Shear Walls Considered For Structure? X Yes Not Applicable Explain Why Not: 9. Is A Continuous Load Path Provided? X Yes Not Applicable Explain Why Not: 10. Design Soil Bearing Pressure: PSF Soil Test Reports Submitted? Yes OP DESIGN PROFESSIONAL CERTIFICATION STATEMENT: I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie County. I also certify that structural elements depicted on these plans provide adequate resistance to the design forces specifierJ: I JAMES BUSHOUSE P.E. #20311 C.A.#27565 '1 A' h Date, and Seal Revised 07/25/2014 Print Name Cert # & Co. Cert Auth. JAMES BUSHOUSE INC 216 E MAGNOLIA STREET, ARCADIA, FL 34266 Company Name & Address �� Copy