HomeMy WebLinkAboutEnergy CodeFORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: ARBUCCI RESIDENCE LOT #39 Builder Name: ' Street: 4832 WATERSONG WAY Permit Office: ST. LUCIE COUNTY City, State, Zip: ST. LUCIE COUNTY, FL, Permit Number: Owner: MARIO ARBUCCI Jurisdiction: Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types(4761.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Int Insul, Exterior R=20.0 4671.00 ft2 b. Frame - Wood, Adjacent R=19.0 90.00 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 4 d. N/A R= ft2 10. Ceiling Types (2043.0 sqft.) Insulation Area 5. Is this a worst case? No a. Roof Deck (Unvented) R=22.0 2043.00 ft2 6. Conditioned floor area above grade (ft2) 4231 b. N/A R= ft2 Conditioned floor area below grade (ft2) 0 c. R= ft2 11. Ducts R ft2 7. Windows(947.0 sqft.) Description Area a. Sup: Attic, Ret: Attic, AH: Attic 6 375 a. U-Factor: Dbl, U=0.79 585.00 ft2 b. Sup: Attic, Ret: Attic, AH: Attic 6 325 SHGC: SHGC=0.28 b. U-Factor: Dbl, U=1.06 240.00 ft2 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.39 a. Central Unit 48.0 SEER:17.00 b. Central Unit 36.0 SEER:17.50 c. U-Factor: Dbl, U=1.06 80.00 ft2 SHGC: SHGC=0.30 13. Heating systems kBtu/hr Efficiency d. U-Factor: other (see details) 42.00 ft2 a. Electric Strip Heat 34.0 COP:1.00 SHGC: other (see details) b. Electric Strip Heat 27.0 COP:1.00 Area Weighted Average Overhang Depth: 4.294 ft. Area Weighted Average SHGC: 0.305 14. Hot water systems a. Electric Cap: 80 gallons 8. Floor Types (1659.5 sqft.) Insulation Area EF: 0.950 a. Raised Floor R=19.0 1587.50 ft2 b. Conservation features b. Raised Floor R=0.0 72.00 ft2 None c. N/A R= ft2 15. Credits Pstat Glass/Floor Area: 0.224 Total Proposed Modified Loads: 143.95 PASS Total Baseline Loads: 144.22 1 hereby certify that the plans and specifications covered by Review of the plans and &.0iE S7. 0�� this calculation are in compliance with the Florida Energy specifications covered by this Code. calculation indicates compliance with the Florida Energy Code. ti pnx %. -:= .'��•. ,07� PREPARED BY' DATE: - Before construction is completed this building will be inspected for compliance with Section 553.908 ►� * "' I hereby certify that this buildin desig ed, is in compliance Florida Statutes. ✓� 5S COD with the Florida Energy C HrF,'1�� OWNER/AGENT: BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handier enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). File Copy 7/17/2018 7:33 AM EnergyGauge® USA Section R405.4.1 Compliant Software Page 1 of 8 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: ARBUCCI RESIDENCE LOT Bedrooms: 4 Address Type: Street Address Building Type: User Conditioned Area: 4231 Lot # Owner Name: MARIO ARBUCCI Total Stories: 3 Block/Subdivision: # of Units: 1 Worst Case: No PlatBook: Builder Name: Rotate Angle: 0 Street: 4832 WATERSONG W Permit Office: ST. LUCIE COUNTY Cross Ventilation: No County: St. Lucie Jurisdiction: Whole House Fan: No City, State, Zip: ST. LUCIE COUNTY, Family Type: Single-family FL, New/Existing: New (From Plans) Comment: CLIMATE / Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 UNIT 1 2343 25695 2 UNIT 2 1888 16992 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 FLEX ROOM 254 2286 No 0 1 Yes Yes Yes 2 LAUND. 65 585 No 0 1 Yes Yes Yes 3 CABANA 100 900 No 0 1 Yes Yes Yes 4 STAIR 99 891 No 0 1 Yes Yes Yes 5 FOYER 244 2196 No 0 1 Yes Yes Yes 6 ELE 25 225 No 0 1 No Yes Yes 7 GREAT ROOM 564 6768 No 0 1 Yes Yes Yes 8 STAIRWAY 243 2916 No 0 1 Yes Yes Yes 9 KITCHEN 300 3600 Yes 0 1 Yes Yes Yes 10 LAUNDRY 82 984 No 0 1 Yes Yes Yes 11 BEDROOM 4 190 2280 No 1 1 1 Yes Yes Yes 12 ELEVATOR 25 300 No 0 1 No Yes Yes 13 BATH 4 60 720 No 0 1 Yes Yes Yes 14 POWDER 72 864 No 0 1 Yes Yes Yes 15 A/C 2 20 180 No 0 1 No Yes Yes 16 MASTER BATH 200 1800 No 0 1 Yes Yes Yes 17 TOILET 24 216 No 0 1 Yes Yes Yes 18 M WIC 83 747 No 0 1 Yes Yes Yes 19 WIC 48 432 No 0 1 No Yes Yes 20 WIC 2 42 378 No 0 1 Yes Yes Yes 21 MASTER SUITE 515 4635 No 0 1 1 Yes Yes Yes 7/17/2018 7:33 AM EnergyGauge® USA Section R405.4.1 Compliant Software Page 2 of 8 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 22 BEDROOM 2 195 1755 No 0 1 1 Yes Yes Yes 23 HALLWAY 228 2052 No 0 1 Yes Yes Yes • 24 STARIWAY. 104 936 No 0 1 Yes Yes Yes 25 BATH 2 50 450 No 0 1 Yes Yes Yes 26 WIC 3 50 450 No 0 1 Yes Yes Yes 27 BEDROOM 3 168 1512 No 0 1 1 Yes Yes Yes 28 BATH 3 50 450 No 0 1 Yes Yes Yes 29 OFFICE 131 1179 No 0 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Raised Floor FLEX ROOM ---- ____ 254 ft2 19 0 1 0 2 Raised Floor LAUND. ____ _--- 65 ft2 19 0 1 0 3 Raised Floor CABANA ____ -___ 100 ft2 19 0 1 0 4 Raised Floor STAIR ---- ____ 99 ft2 19 0 1 0 5 Raised Floor FOYER ---- ___- 244 ftZ 19 0 1 0 6 Raised Floor ELE ---- ____ 25 ftz 19 0 1 0 7 Raised Floor STAIRWAY ____ -_-_ 56 ftz 19 0 0 1 8 Raised Floor KITCHEN ____ -_-_ 90 ft2 19 0 0 1 9 Raised Floor KITCHEN ---- ____ 35 ftZ 19 0 1 0 10Raised Floor LAUNDRY ____ ____ 72 ft2 0 0 0 1 11Raised Floor LAUNDRY -___ _--- 10 ftz 19 0 1 0 12Raised Floor BEDROOM 4 ---- 190 ft2 19 0 0 1 13Raised Floor ELEVATOR ---_ ____ 25 ftz 19 0 0 1 14Raised Floor BATH 4 -___ -___ 60 ft2 19 0 0 1 15Raised Floor POWDER ____ ____ 8 ft2 19 0 0 1 16Raised Floor POWDER ____ 56 ft2 19 0 1 0 17Raised Floor A/C 2 ____ ____ 5 ft2 19 0 0 1 18Raised Floor MASTER BATH ____ ___- 28 ft2 19 0 1 0 19Raised Floor MASTER SUITE ---- __-_ 4.5 ft2 19 0 1 0 20Raised Floor BEDROOM 3 -___ ___- 112 ft2 19 0 1 0 21Raised Floor BATH 3 --__ --_- 40 ft2 19 0 1 0 7/17/2018 7:33 AM EnergyGauge® USA Section R405.4.1 Compliant Software Page 3 of 8 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 22Raised Floor OFFICE ---- ---- 81 ft2 19 0 1 0 ROOF V Roof Gable Roof Solar SA Emitt Emitt Deck Pitch # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Gable or Shed Metal 2209 ft2 348 ft2 Light 0.6 No 0.9 No 22 18.4 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Unvented 0 2096 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Unvented) FLEX ROOM 22 Blown 101 ft2 0.1 Wood 2 Under Attic (Unvented) LAUND. 22 Blown 25 ft2 0.1 Wood 3 Under Attic (Unvented) GREAT ROOM 22 Blown 36 ft2 0.1 Wood 4 Under Attic (Unvented) MASTER BATH 22 Blown 200 ft2 0.1 Wood 5 Under Attic (Unvented) TOILET 22 Blown 24 ft2 0.1 Wood 6 Under Attic (Unvented) M WIC 22 Blown 83 ft2 0.1 Wood 7 Under Attic (Unvented) WIC 22 Blown 48 ft2 0.1 Wood 8 Under Attic (Unvented) WIC 2 22 Blown 42 ft2 0.1 Wood 9 Under Attic (Unvented) MASTER SUITE 22 Blown 515 ft2 0.1 Wood 10 Under Attic (Unvented) BEDROOM 2 22 Blown 195 ft2 0.1 Wood 11 Under Attic (Unvented) HALLWAY 22 Blown 228 ft2 0.1 Wood 12 Under Attic (Unvented) STARIWAY. 22 Blown 104 ft2 0.1 Wood 13 Under Attic (Unvented) BATH 2 22 Blown 50 ft2 0.1 Wood 14 Under Attic (Unvented) WIC 3 22 Blown 50 ft2 0.1 Wood 15 Under Attic (Unvented) BEDROOM 3 22 Blown 168 ft2 0.1 Wood 16 Under Attic (Unvented) BATH 3 22 Blown 50 ft2 0.1 Wood 17 Under Attic (Unvented) OFFICE 22 Blown 124 ft2 0.1 Wood . WALLS A ()cot Adjacent Cavity Width 10 Wall lype SpaceR_VaEt Height n Et n Area Sheathing Framing Solar Below 1 N Exterior Concrete Block - Int Ins&ILEX ROOM 20 18 0 9 0 162.0 ft2 9 0 0.5 0 2 E Exterior Concrete Block - Int InsirlLEX ROOM 20 16 0 9 0 144.0 ft2 9 0 0.5 0 3 S Exterior Concrete Block - Int InsEILEX ROOM 20 5 0 9 0 45.0 ft2 9 0 0.5 0 4 N Exterior Concrete Block - Int Insul LAUND. 20 10 0 9 0 90.0 ft2 9 0 0.5 0 5 E Exterior Concrete Block - Int Insul LAUND. 20 1 0 9 0 9.6 ft2 9 0 0.5 0 6 W Exterior Concrete Block - Int Insul LAUND. 20 7 0 9 0 63.0 ft2 9 0 0.5 0 _ 7 W Exterior Concrete Block - Int Insul CABANA 20 10 0 9 0 90.0 ft2 9 0 0.5 0 _ 8 W Exterior Concrete Block - Int Insul STAIR 20 11 0 9 0 99.0 ft2 9 0 0.5 0 7/17/2018 7:33 AM EnergyGauge® USA Section R405.4.1 Compliant Software Page 4 of 8 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below Space le Et In Pt In Area R-\/.qf-fe Eraction Ah 9 S Exterior Concrete Block - Int Insul FOYER 20 8 0 9 0 72.0 ft2 9 0 0.5 0 10 W Exterior Concrete Block - Int Insul FOYER 20 21 0 9 0 189.0 ft2 9 0 0.5 0 11 N Exterior Concrete Block - Int Ins(HREAT ROO 20 21 0 12 0 252.0 ft2 9 0 0.5 0 12 NE Exterior Concrete Block - Int InsIHREAT ROO 20 9 11 12 0 119.0 ft2 9 0 0.5 0 13 E Exterior Concrete Block - Int InsGREAT ROO 20 14 0 12 0 168.0 ft2 9 0 0.5 0 14 W Exterior Concrete Block - Int InsGREAT ROO 20 21 0 12 0 252.0 ft2 9 0 0.5 0 15 W Exterior Concrete Block - Int InsLSTAIRWAY 20 24 0 12 0 288.0 ft2 9 0 0.5 0 16 E Exterior Concrete Block - Int InsulKITCHEN 20 14 0 12 0 168.0 ft2 9 0 0.5 0 17 E Exterior Concrete Block - Int InsuLAUNDRY 20 9 0 12 0 108.0 ft2 9 0 0.5 0 _ 18 E Exterior Concrete Block - Int InsBEDROOM 4 20 13 0 12 0 156.0 ft2 9 0 0.5 0 19 S Exterior Concrete Block - Int InsBEDROOM 4 20 14 0 12 0 168.0 ft2 9 0 0.5 0 20 S Exterior Concrete Block - Int Insul BATH 4 20 5 0 12 0 60.0 ft2 9 0 0.5 0 21 W Exterior Concrete Block - Int Insul BATH 4 20 4 0 12 0 48.0 ft2 9 0 0.5 0 _22 S Exterior Concrete Block - Int InsuIPOWDER 20 9 0 12 0 108.0 ft2 9 0 0.5 0 _23 W Exterior Concrete Block - Int InsuIPOWDER 20 8 0 12 0 96.0 ft2 9 0 0.5 0 _24 N Exterior Concrete Block - Int InsUASTER BA 20 14 0 9 0 126.0 ft2 9 0 0.5 0 _25 E Exterior Concrete Block - Int InsUASTER BA 20 6 0 9 0 54.0 ft2 9 0 0.5 0 _26 W Exterior Concrete Block - Int InsUASTER BA 20 16 0 9 0 144.0 ft2 9 0 0.5 0 _27 W Exterior Concrete Block - Int Insul TOILET 20 4 0 9 0 36.0 ft2 9 0 0.5 0 _28 W Exterior Concrete Block - Int Insul M WIC 20 12 0 9 0 108.0 ft2 9 0 0.5 0 _29 E Exterior Concrete Block - Int Insul WIC 2 20 6 0 9 0 54.0 ft2 9 0 0.5 0 _30 N Exterior Concrete Block - Int InsMASTER SUI 20 14 0 9 0 126.0 ft2 9 0 0.5 0 _31 E Exterior Concrete Block - Int InsMASTER SUI 20 20 0 9 0 180.0 ft2 9 0 0.5 0 _32 E Exterior Concrete Block - Int InsBEDROOM 2 20 13 0 9 0 117.0 ft2 9 0 0.5 0 33 W Exterior Concrete Block - Int InsuHALLWAY 20 7 0 10 0 70.0 ft2 9 0 0.5 0 _34 W Exterior Concrete Block - Int InsiSTARIWAY. 20 13 0 9 0 117.0 ft2 9 0 0.5 0 _35 E Exterior Concrete Block - Int Insul BATH 2 20 5 0 9 0 45.0 ft2 9 0 0.5 0 _36 E Exterior Concrete Block - Int Insul WIC 3 20 5 0 9 0 45.0 ft2 9 0 0.5 0 _37 E Exterior Concrete Block - Int InsBEDROOM 3 20 12 0 9 0 108.0 ft2 9 0 0.5 0 _38 S Exterior Concrete Block - Int InsBEDROOM 3 20 14 0 9 0 126.0 ft2 9 0 0.5 0 _39 S Exterior Concrete Block - Int Insul BATH 3 20 5 0 9 0 45.0 ft2 9 0 0.5 0 _40 W Exterior Concrete Block - Int Insul BATH 3 20 3 0 9 0 27.0 ft2 9 0 0.5 0 _41 S Exterior Concrete Block - Int Insul OFFICE 20 9 0 9 0 81.0 ft2 9 0 0.5 0 _42 W Exterior Concrete Block - Int Insul OFFICE 20 12 0 9 0 108.0 ft2 9 0 0.5 0 _43 N Garage Frame - Wood OFFICE 19 10 9 90.0 ft2 0.23 0.5 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 N Wood FLEX ROOM None .2 .1 .1 .0 ft2 7/17/2018 7:33 AM EnergyGauge® USA Section R405.4.1 Compliant Software Page 5 of 8 •' ' - � � I`I1�ji;��Jl�il��iF1:�'L�3.1�[�7:����i:7�:Z�7:i� WINDOWS Orientation shown is the entered, Proposed orientation. V Wall Overhang # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 N 1 Vinyl Low-E Double Yes 1.06 0.39 N 80.0 ft2 4 ft 0 in 1 ft 4 in Drapes/blinds Exterior 1 m 2 E 2 Vinyl Low-E Double Yes 0.79 0.28 N 40.0 ft2 2 ft 0 in 7 ft 0 in None None 3 N 4 Vinyl Low-E Double Yes 0.79 0.28 N 24.0 ft2 2 ft 0 in 7 ft 0 in None None 4 W 7 Vinyl Low-E Double Yes 0.79 0.28 N 10.0 ft2 2 ft 0 in 1 ft 4 in None None 5 S 9 Vinyl Low-E Double Yes 0.79 0.28 N 48.0 ft2 5 ft 0 in 1 ft 4 in None None 6 W 10 Vinyl Low-E Double Yes 0.79 0.28 N 40.0 ft2 2 ft 0 in 1 ft 4 in None None 7 N 11 Vinyl Low-E Double Yes 1.06 0.39 N 160.0 ft2 8 ft 0 in 1 ft 4 in None None 8 E 13 Vinyl Low-E Double Yes 0.79 0.28 N 56.0 ft2 2 ft 0 in 1 ft 4 in None None 9 W 14 Vinyl Low-E Double Yes 0.79 0.28 N 42.0 ft2 2 ft 0 in 1 ft 4 in None None 10 W 15 Vinyl Low-E Double Yes 0.79 0.28 N 24.0 ft2 2 ft 0 in 1 ft 4 in None None 11 E 16 Vinyl Low-E Double Yes 0.79 0.28 N 18.0 ft2 2 ft 0 in 1 ft 4 in None None 12 E 17 Vinyl Low-E Double Yes 0.79 0.28 N 14.0 ft2 2 ft 0 in 1 ft 4 in None None 13 S 19 Vinyl Low-E Double Yes 0.79 0.28 N 40.0 ft2 5 ft 0 in 1 ft 4 in Drapes/blinds Exterior 1 14 S 19 Vinyl Low-E Double Yes 0.79 0.28 N 5.0 ft2 5 ft 0 in 1 ft 4 in None None 15 S 19 Vinyl Low-E Double Yes 0.79 0.28 N 8.0 ft2 2 ft 0 in 1 ft 4 in None None 16 S 20 Vinyl Low-E Double Yes 0.79 0.28 N 8.0 ft2 2 ft 0 in 1 ft 4 in None None 17 W 23 Vinyl Low-E Double Yes 0.79 0.28 N 8.0 ft2 2 ft 0 in 1 ft 4 in None None 18 N 24 Vinyl Low-E Double Yes 0.22 0.17 N 18.0 ft2 2 ft 0 in 1 ft 4 in None None 19 N 24 Vinyl Low-E Double Yes 0.22 0.17 N 24.0 ft2 2 ft 0 in 1 ft 4 in None None 20 W 27 Vinyl Low-E Double Yes 0.79 0.28 N 10.0 ft2 2 ft 0 in 1 ft 4 in None None 21 N 30 Vinyl Low-E Double Yes 1.06 0.3 N 80.0 ft2 8 ft 8 in 1 ft 4 in None None 22 E 31 Vinyl Low-E Double Yes 0.79 0.28 N 20.0 ft2 2 ft 0 in 1 ft 4 in None None 23 E 32 Vinyl Low-E Double Yes 0.79 0.28 N 20.0 ft2 2 ft 0 in 1 ft 4 in None None 24 W 33 Vinyl Low-E Double Yes 0.79 0.28 N 20.0 ft2 2 ft 0 in 1 ft 4 in None None 25 E 35 Vinyl Low-E Double Yes 0.79 0.28 N 10.0 ft2 2 ft 0 in 1 ft 4 in None None 26 E 37 Vinyl Low-E Double Yes 0.79 0.28 N 20.0 ft2 2 ft 0 in 1 ft 4 in None None 27 S 38 Vinyl Low-E Double Yes 0.79 0.28 N 40.0 ft2 5 ft 0 in 9 ft 0 in None None 28 S 38 Vinyl Low-E Double Yes 0.79 0.28 N 10.0 ft2 2 ft 0 in 1 ft 4 in None None 29 S 39 Vinyl Low-E Double Yes 0.79 0.28 N 10.0 ft2 2 ft 0 in 1 ft 4 in None None 30 S 41 Vinyl Low-E Double Yes 0.79 0.28 N 40.0 ft2 5 ft 0 in 9 ft 0 in None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 840 ft2 840 ft2 33 ft 9 ft 19 7/17/2018 7:33 AM EnergyGauge® USA Section R405.4.1 Compliant Software Page 6 of 8 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000449 4980.1 273.4 514.18 .4847 7 ' HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 2 Electric Strip Heat/ Electric Strip Heat/ None None COPA 34 kBtu/hr COP:1 27 kBtu/hr 1 2 sys#1 sys#2 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 2 Central Unit/ Central Unit/ Split Split SEER: 17 48 kStu/hr cfm 0.85 SEER: 17.5 36 kBtu/hr cfm 0.85 1 2 sys#1 sys#2 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.95 80 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cert # Company Name Collector Storage System Model # Collector Model # Area Volume FEF None None ft2 DUCTS V # ---- Supply — Location R-Value Area --- Return ---- Air CFM 25 CFM25 Location Area Leakage Type Handler TOT OUT QN RLF HVAC # Heat Cool 1 2 Attic 6 375 ft2 Attic 6 325 ft2 Attic Attic 75 ft2 Default Leakage Attic (Default) (Default) 95 ft2 Default Leakage Attic (Default) (Default) 1 1 2 2 TEMPERATURES Programable Thermostat: Y Coolin [ ]Jan Feb Mar Heating IX] Jan f X� Feb Mar Ventin [ ] Jan [ Feb X Mar Ceiling Fans: Au X Se Oct f Apr f May f Jun 4 Jul AuSeP f Oct]Nov A r Ma X Jun X Jul ri [X A r [ Ma [ Jun [ Jul Aug Se [X Oct [ ]Nov [X] Nov j Dec f X] Dec [ j Dec 7/17/2018 7:33 AM EnergyGauge® USA Section R405.4.1 Compliant Software Page 7 of 8 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 1-leating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Veating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. 0 ft2 Oft 0.3 FLEX ROOM Default(8 Ibs/sq.ft. ft2 ft 0.3 LAUND. Default(8 Ibs/sq.ft. ft2 ft 0.3 CABANA Default(8 Ibs/sq.ft. ft2 ft 0.3 STAIR Default(8 lbs/sq.ft. ft2 ft 0.3 FOYER Default(8 Ibs/sq.ft. ft2 ft 0.3 ELE Default(8 Ibs/sq.ft. ft2 ft 0.3 GREAT ROOM Default(8 Ibs/sq.ft. ft2 ft 0.3 STAIRWAY Default(8 Ibs/sq.ft. ft2 ft 0.3 KITCHEN Default(8 Ibs/sq.ft. ft2 ft 0.3 LAUNDRY Default(8 Ibs/sq.ft. ft2 ft 0.3 BEDROOM 4 Default(8 Ibs/sq.ft. ft2 ft 0.3 ELEVATOR Default(8 Ibs/sq.ft. ft2 ft 0.3 BATH 4 Default(8 lbs/sq.ft. ft2 ft 0.3 POWDER Default(8 Ibs/sq.ft. ft2 ft 0.3 A/C 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 MASTER BATH Default(8 Ibs/sq.ft. ft2 ft 0.3 TOILET Default(8 Ibs/sq.ft. ft2 ft 0.3 M WIC Default(8 Ibs/sq.ft. ft2 ft 0.3 WIC Default(8 Ibs/sq.ft. ft2 ft 0.3 WIC 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 MASTER SUITE Default(8 Ibs/sq.ft. ft2 ft 0.3 BEDROOM 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 HALLWAY Default(8 Ibs/sq.ft. ft2 ft 0.3 STARI WAY. Default(8 Ibs/sq.ft. ft2 ft 0.3 BATH 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 WIC 3 Default(8 Ibs/sq.ft. ft2 ft 0.3 BEDROOM 3 Default(8 Ibs/sq.ft. ft2 ft 0.3 BATH 3 Default(8 Ibs/s .ft. ft2 ft 0.3 OFFICE Name: Test Rater Rating Compant: Test Rater Date: 7)- n.- M 7/17/2018 7:33 AM EnergyGaugeO USA Section R405.4.1 Compliant Software Page 8 of 8 2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: ARBUCCI RESIDENCE LOT #39 Builder Name: Street: 4832 WATERSONG WAY Permit Office: ST. LUCIE COUNTY City, State, Zip: ST. LUCIE COUNTY, FL, Permit Number: Y U Owner: MARIO ARBUCCI Jurisdiction: W Design Location: FL, Fort Pierce U COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall requirements The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with /soffit The insulation in an dropped ceiling/soffit y pp g the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity sealed. with a material having a thermal resistance of R-3 Knee walls shall be sealed. per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/doorjambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spac as. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the drywall. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind p*p*ng and wirffing. Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electrical/phone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids between fire sprinkler cover glates and walls or cemlonas, a. In addition, inspection of log walls shall be in accordance with the provisions of [CC-400. 7/17/2018 7:33 AM EnergyGauge® USA FBC 6th Edition (2017) Compliant Software Page 1 of 1 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 100 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 c) AHU location Attic/Attic 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 4 13. Cooling system: Capacity 84.0 a) Split system SEER varies 5. Is this a worst case? (yes/no) 5. No b) Single package SEER c) Ground/water source SEER/COP 6. Conditioned floor area (sq. ft.) 6. 4231 d) Room unit/PTAC EER e) Other 7. Windows, type and area a) U-factor:(weighted average) 7a. 0.856 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.305 14. Heating system: Capacity 61.0 c) Area 7c. 947.0 a) Split system heat pump HSPF b) Single package heat pump HSPF 8. Skylights c) Electric resistance COP 1.0 a) U-factor:(weighted average) 8a. NA d) Gas furnace, natural gas AFUE b) Solar Heat Gain Coefficient (SHGC) 8b. NA e) Gas furnace, LPG AFUE f) Other 9. Floor type, insulation level: a) Slab -on -grade (R-value) 9a. b) Wood, raised (R-value) 9b. varies 15. Water heating system c) Concrete, raised (R-value) 9c. a) Electric resistance EF 0.95 b) Gas fired, natural gas EF 10. Wall type and insulation: c) Gas fired, LPG EF A. Exterior: d) Solar system with tank EF 1. Wood frame (Insulation R-value) 10A1. e) Dedicated heat pump with tank EF 2. Masonry (Insulation R-value) 10A2. 20.0 0 Heat recovery unit HeatRec% B. Adjacent: g) Other 1. Wood frame (Insulation R-value) 10131. 19.0 2. Masonry (Insulation R-value) 10132. 16. HVAC credits claimed (Performance Method) 11. Ceiling type and insulation level a) Ceiling fans a) Under attic 11 a. 22.0 b) Cross ventilation No b) Single assembly 11 b. c) Whole house fan No c) Knee walls/skylight walls 11 c. d) Multizone cooling credit d) Radiant barrier installed 11 d. No e) Multizone heating credit f) Programmable thermostat Yes *Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT I certify that this home has complied with the F rida Building Code, Energy Conservation, through the above energy saving features which will be install (or exc ded) in this home before final inspection. Otherwise, a new EPL display card will be completed4'on ins Iled code compliant features. Builder Signature: d/ ! Date: Address of New Home: 4832 WATERSONG WAY City/FL Zip: ST. LUCIE COUNTY, FL 7/17/2018 7:33:12 AM EnergyGauge® USA 6.0.02 - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1