Project Summa Job: -�- wrightsoft® UNIT 7 � Data: JUNE 14, 2018 By: QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466-6796 Email: QUICKCALCS@,AOL.COM Project Information For: MARIOARBUCCI LOT 46 4832 WATERSONG WAY ST. LUCIE COUNTY FL Notes: Weather: Fort Pierce, FL, US Winter Design Conditions . Outside db 42 OF Inside db 70 OF Design TD 28 OF Heating Summary Structure 30495 Btuh Ducts 4466 Btuh Central vent (0 cfm) 0 Btuh (none) Humidification 0 Btuh Piping 0 Btuh Equipment load 34961 Btuh Infiltration Method Simplified Construction quality Average Fireplaces 0 Heating Cooling Area (ftz) 2466 2466 Volume (ft3) 27900 27900 Airchanges/hour 0.46 0.23 Equiv AVF (cfm) 213 109 Heating Equipment Summary Make Trade Model AHRI ref Efficiency Heating Input Heating output Temperature rise Actual airflow Air flow factor Static pressure Space thermostat 100 EFF 11.9 kW 40 23 Btuh 1600 cfm 0.046 cfm/Btuh 0.50 in H2O Summer Design Conditions Outside db 90 OF Inside db 75 OF Design TD 15 OF Daily range Relative humidity L 50 % Moisture difference 61 gr/Ib Sensible Cooling Equipment Load Sizing Structure 27213 Btuh Ducts 3433 Btuh Central vent (0 cfm) 0 Btuh (none) Blower 0 Btuh Use manufacturer's data n Rate/swin multiplier 0.95 Equipmen� sensible load 29113 Btuh Latent Cooling Equipment Load Sizing Structure 4740 Btuh Ducts 3729 Btuh Central vent (0 cfm) 0 Btuh (none) Equipment latent load 8469 Btuh Equipment Total Load (Sen+Lat) 37582 Btuh Req. total capacity at 0.70 SHR 3.5 ton Cooling Equipment Summary Make Carrier Trade Cond 24ANB748CO031 Coil FV4CN13006 AHRI ref 5635352 Efficiency 13.5 EER,17 SEER Sensible cooling 33600 Btuh Latent000ling 14400 Btuh Total cooling 48000 Btuh Actual airflow 1600 cfm Airflowfactor 0.052 cfm/Btuh Static pressure 0.50 in H2O Load sensible heat ratio 0.78 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. -Fk wrightsoft® 2018-JU-1 7 07:33.40 aM,,.. •..-„ • . �_ Right-Sute®Uriversal2018 18.0.16 RSU08101 Page l CKUoameris\WrightsoftHVACWRBUCCI,MARIO.rup CaIc=MJ8 Frort Door faces: SW - 1- wrightsoft, Pro'ect Summary UN2 QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone:772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@,40L.COM For. MARIOARBUCCI LOT 46 4832 WATERSONG WAY ST. LUCIE COUNTY FL Notes: Weather: Fort Pierce, FL, US Winter Design Conditions Outside db 42 OF Inside db 70 OF Design TD 28 OF Heating Summary Structure 20770 Btuh Ducts 4460 Btuh Central vent (0 cfm) 0 Btuh (none) Humidification Piping Equipment load Infiltration Method Construction quality Fireplaces 0 Bttuuh 25230 Btuh Simplified Average 0 Area (ft�) Wlume (ft3) Heating Cooling 1765 1765 17650 17650 Air changes/hour 0.44 0.22 Equiv AVF (cfm) 129 66 Heating Equipment Summary Make Trade Model AHRI ref Efficiency Heating Input Heating output Temperature rise Actual airflow Air flow factor Static pressure Space thermostat 100 EFF 7.2 kW 246100 oBFtuh 1200 cfm 0.048 cfm/Btuh 0.50 in H2O Job: Date: JUNE 14, 2018 By: Summer Design Conditions Outside db Inside db 90 75 OF OF Design TD Daily range Relative humidity Moisture difference 15 L 50 61 OF % grAb Sensible Cooling Equipment Load Sizing Structure 19785 Btuh Ducts 3084 Btuh Central vent (0 clim) 0 Btuh (none) Blower 0 Btuh Use manufacturer's data n Rate/swin multipplier 0.95 Equipmenisensible load 21726 Btuh Latent Cooling Equipment Load Sizing Structure 2754 Btuh Ducts 2564 Btuh Central vent (0 cfm) 0 Btuh (none) Equipment latent load 5318 Btuh Equipment Total Load (Sen+Lat) 27044 Btuh Req. total capacity at 0.70 SHR 2.6 ton Cooling Equipment Summary Make Carrier Trade CARRIERAIR CONDITIONING Cond 24ANB736AO031 Coil FV4CNB006L AHRI ref 7875378 Efficiency 13.5 EER,17.5 SEER Sensible cooling 25200 Btuh Latent cooling 10800 Btuh Total cooling 36000 Btuh Actual airflow 1200 cfm Air flow factor 0.052 cfm/Btuh Static pressure 0.50 in H2O Load sensible heat ratio 0.81 Flle Copy Calculations approved byACCA to meet all requirements of Manual J 8th Ed. wrightsoft- 2018-Jul-17 07:33.40 •M,= • �,�-w� . , Right-SdteSUriversal20l8 l8.O.l6 RSU08101 Page 2 ACCA CK\Doarnerts\WrigtboftWACWRBUCCI,MARIO.np Calc=MJB Front Door faces: SW wrightsoft° R1ght-J® Worksheet Job: UNIT 1 Date: JUNE 14, 2018 QUICK CALCS, INC. By: 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@,AOL.COM 1 2 3 4 5 Room name Exposed wall Room height Room dimensions Room area UNIT 1 278.0 It 11.3 It d 2466.0 fF FLEX ROOM 35.0 ft 10.0 It heat/cool 18.0 x 17.0 It 306.0 tP Ty Construction number U-value (Btuh/fR°F) Or HTM (Btuh/ftn Area (ft� or perimeter (ft) Load (Btuh) Area (ftz) or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 11 -- - 13B 5ocias --- -- 10A-v 106-v IA-clov 1A-clov 1A-r1obd 1A.Llomd-_-___ 1313-5ocx5 1D-2om 1 D-c2om 1Dt•2ov 1 D-c2ov 1 D-c2ov 1D•t2ov _________ 136-5oous 10A-m 10A-m 10A-v 1 D-c2om 1 D-c2ov 1313-5cons 1A-hlov 1A-h1ov 1 D-c2om 1 D-c2om 1 D-c2ov 1D-c2ov 1 D-c2ov ----- --- 19G19csCP-- _ �l27.69 22A:tp1 -, -- 0.064 0.820 0.600 0.900 0.900 1.080 _ 1,2T0 0.064 0.870 0.870 0.570 0.570 0.570 0_570 0.064 1.670 1.670 0.820 0.870 0.570 --_0.570 0.064 0.900 0.900 0.870 0.870 0.570 0.570 0.570 - -- -._-: 0.408 . 0.049 0.989 ne ne ne ne ne ne -ne_ se se se se se se se_ sw sw sw sw sw sw _sw. nw nw nw nw nw nw nw nw -- _i. 22.96 16.80 0.00 0.00 0.00 -_ 3.5.56 1.79 0.00 0.00 15.96 15.96 15.96 ___ 15.96 1.79 0.00 46.76 22.96 0.00 15.96 _- 15.96. 1.79 25.20 25.20 0.00 0.00 15.96 15.96 15.96 -_- 1.59 _ 0.48. _-27.69 14.90 25.00 0.00 0.00 0.00: __ 43:03-- 0.89 0.00 0.00 47.30 36.14 37.73 •-_ 37�73 0.89 0.00 15.98 15.21 0.00 20.29 -- -30;55 0.89 49.12 49.12 0.00 0.00 46.91 46.91 46.91 --128. _ 1.49 --026 0.00 __ 0,0.0 48 24 0 0 0 160 890 0 0 20 18 14 __-_ 56 416 0 40 48 " 0 5 �_-16 1210 10 20 0 0 8 24 42 -_- 520 _ 125 _742 846 -_.-_83 --_-384 0 0 0 0 0 _--0, 782 0 0 0 7 5 _- _ 20 - 307 0 40 48 0 5 -._ 10 1106 0 0 0 0 0 0 0 a---- __52Q _520 _ _ 125- _ 742 -- 102 -17 ' 688 1102 403 0 0 0 _ 5690. 1401 0 0 319 287 223 - __ 694 550 0 1870 1102 0 80 .------255 1982 252 504 0 0 128 383 670 -- ----- ___ 1325 -._-198 353, 2825 _466 -- 342 715 600 0 0 0 _.6884 696 0 0 946 650 528 _ 2113 273 0 639 730 0 101 ___-_-489 984 491 982 0 0 375 1126 1970 --- - - - _.v 667 __-_ _ _1.86 _ 189 237 1102 0 0 0 0 T-_-_0 269 0 0 319 0 0 ___ __0 0 0 0 0 0 0 ----0 0 0 0 0 0 0 0 0 -- - _-_382 _--_51- --- 0 969 ----- 0 -- 117 715 0 0 0 0 133 0 0 946 0 0 ___ _ 0 _ 0 0 0 0 0 0 -------Q 0 0 0 0 0 0 0 0 ---- --- -.-- 192, _ _ _ 48 ------0 ---186 48 0 0 0 0 ---0 170 0 0 20 0 0 __ 0 0 0 0 0 0 0 __-0 0 0 0 0 0 0 0 0 - - - 150 32 0 -- 132 0 0 0 0 0 ___0 150 0 0 0 0 0 _ __ 0 0 0 0 0 0 0 -�-- 0 0 0 0 0 0 0 0 0 - ---- 150 32 _^__0 35 ._-___0 G L-__ _ - - F - F _ _ -__- 306 -__-�0 ___ 0 _0 6 c) AED excursion 512 -56 Enxelope losstgain 23952 23191 3329 2096 12 a) Infiltration b) Room ventilation 6543 0 1792 01 731 0 200 0 13 Intemal gains Ooarpants@ 230 Appliancesrother 1 230 2000 0 0 0 Subtotal (lines6 to 13) 30495 27213 4060 2296 14 15 Less external load Lesstansfer Redistribution Subtotal Ductloads 15% 13% 0 0 0 30495 4466 0 0 0 27213 3433 0% 0% 0 0 0 4060 0 0 0 0 2296 0 Total room load Air required (dm) 34961 1600 30645 1600 4060 186 2296 120 Calculations approved bvACCAto meet all reauirements of Manual J 8th Ed. AW 2018-JLI-1707:33:40 Right-Sute®Uriversal 201818.0.16 RSUD8101 Page 1 CK1Doorrnents\WrigttsoftHVAC\ARBUCCI,MARIO.np Calc=MJB Front Door faces: SW 1- wrightsoft® Right-M Worksheet Job: UNIT 1 Date: JUNE 14, 2018 QUICK CALCS, INC. By: 317 ST. LUCIE LN., Fr.. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS , OL.COM 1 2 3 4 5 Room name Exposed wall Room height Room dimensions Room area LAUND. 17.0 ft 10.0 It heaV000l 1.0 x 69.0 ft 69.0 ftz CABANA 10.0 ft 10.0 ft heaU000l 10.0 x 10.0 it 100.0 ft' Ty Construction number U-value (BtuhW-01F) Or HTM (Btuhflt2) Area (fl or perimeter (ft) Load (Btuh) Area (ftz) or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 11 W - 13B-5oohss - ' 10A v 10B-v IA-clov 1A- lov 1A-r1obd 1A-r1omd-_- 13B-500As 1D-c2om 1 D- tom 1 D-c2ov 1 D-c2ov 1 D-c2ov 1D-c2ov 13B-5oohs v -- 1 OA-m 10A-m 10A-v 1D-c2om - 1 D-c2ov 1D=c2ov 13B-500ros 1A-h1ov 1A-h1ov 1 D-c2om 1 D-c2om 1 D-c2ov 1 D-c2ov 1 D-c2ov 12C Qsw _ -__ 16X19-0md .._- _ _ 19G_19Csq�_ 22A-tpl---_.- �- 0.064 0.820 0.600 0.900 0.900 1.080 -- 1.270. 0.064 0.870 0.870 0.570 0.570 0.570 0.570 0.064 1.670 1.670 0.820 0.870 0,570 0.5.70 0.064 0.900 0.900 0.870 0.870 0.570 0.570 0.570 ._ 0.091. - - 0.408 _ 0.0$9 ne ne ne ne ne ne -ne- se se se se se se se sw sw sw sw sw sw _sw- nw nw nw nw nw nw nw nw _ __ __ ___ -1.79 22.96 16.80 0.00 0.00 0.00 - 35,56 1.79 0.00 0.00 15.96 15.96 15.96 15.96 f.79 0.00 46.76 22.96 0.00 15.96 15..96 1.79 25.20 25.20 0.00 0.00 15.96 15.96 15.96 __.2.55 _-1.59 �0.4t3 -0.89 14.90 25.00 0.00 0.00 0.00 -_-43.03 0.89 0.00 0.00 47.30 36.14 37.73 T 37.73 0.89 6.00 , 15.98 1521 0.00 20.29 _-30.55, 0.89 49.12 49.12 0.00 0.00 46.91 46.91 46.91 - 1.28- --• 1.49 -- 9.2b. 100 0 24 0 0 0 -- 76 0 0 0 0 0; 90 - TM 136 0 403 0 0 0 _-_--_0- 0 0 0 0 0 0 0 . _, -a 0 0 0 0 01 _ 0 125 0 0 0 0 0 0 0 68 0 600 0 0 0 _._._ _0 0 0 0 0 0 0 0 _ _._ 0 0 0 0 0 0 __0 62 0 0 0 0 0 0 0 -- ---0 ---_- 28 - -- 0 --- 0 -- 0 0 0 0 0 0 0 0 0 0 0 0 0 0 .._._-- 0 0 0 0 0 0 -.-___0. 100 10 0 0 0 0 0 0 -----0 .__ - 0 -0 - 100 - W-- 0 0 0 0 0 0 - -_ 0 0 0 0 0 0 0 0 � 0 ---0, 0 0 0 0 0 -__----0 90 0 0 0 0 0 0 0 -- --0 -- _ 0 - -- - -0 -- - -10 ------0 0 0 0 0 0 _ ----A 0 0 0 0 0 0 _ 0 �___.- 0- 0 0 0 0 0 _ --___0 161 252 0 0 0 0 0 0 --_-0- _._.. _ 0 --- --0 ---2T7 -" - 0 0 0 0 0 0 0 0 0 0 0 0 0 __0- 0 0 0 0 0 _-_-O, 80 491 0 0 0 0 0 0 --- -0 .__ 0 - --_0. -- 0 G . _--___-Q 0 0 0 0 0 0 0 o 0 0 0 0 0 _-_ _-0 70 0 0 0 0 0 0 0 -- - - -0- _ -__ _ 1.9. -- -69 _ __. 0 0 0 0 0 0 0 -o 0 0 0 0 0 0 G 70 0 0 0 0 0 0 0 ----. 0 19 -- - -'0 - - 17 _P_- C_ F F.__ _-_---0. -_ - 30 - -0 47-1 6 c) AED excursion -81 101 Envelope loss(gain 1166 677 690 672 12 a) Infiltration b) Room ventilation 355 0 97 0 209 0 57 0 13 Internal gains Occupants@ 230 Appliancesrother 0 0 0 0 0 0 Subtotal (lines 6 to 13) 1521 774 .899 729 14 15 Less extemalload Lesstransfer Redistribution Subtotal Ductloads 21% 16% 0 0 0 1521 325 0 0 0 774 128 0% 0% 0 0 0 899 0 0 0 0 729 0 Total room load Air required (dm) 1845 84 902 47 1411 899 729 38 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. Am- 2018-Jul-1707:33:40 �� u 1.1--^mil" RigI1-Sute®Urdversa120181&0.16RSU08101 Paget CK1DoamerislWrightsoftWACWRBUCCI,MARIO.np Calc=MJ8 Front Door faces: SW -�- wrightsoft° Right-J® Worksheet Job: UNIT 1 Date: JUNE 14, 2018 By: QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466-6796 Email: QUICKCALCS@ OL.COM 1 2 3 4 5 Room name Exposedwall Room height Room dimensions Room area STAIR 6.0 ft 10.0 It heat(000l 9.0 x 6.0 ft 54.0 It` FOYER 29.0 ft 10.0 ft heat/000l 1.0 x 247.0 It 247.0 ft Ty Construction number U-value (BtuhlfF-°F) Or HTM (Btuh/ft2) Area (fF) or perimeter (ft) Load (Btuh) Area (ftz) or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 11 W 13B-5oays 10A-v 1013-v 1A-clov 1A-clov 1A-r1obd 1A-r1 omd----_-. _ _ 136-500As 1 D- tom 1 Dc2om 1 D-c2ov 1 D-c2ov 1 D-c2ov 1D cloy 13B-5ocws 10A-m 10A-m 10A-v 1 D-c2om 1 D-c2ov 1 D-aov ----- 1313-500As 1A-hlov 1A-hlov 1D-c2om 1 D-c2om 1 D-c2ov 1 D-c2ov 1DQov 16X19Omd9G-- -.. 11.9csc _---- 0 0 0 0 0 0 ----- - 0 0 0 0 0 0 0 - -0 0 0 0 0 0 0 0 M 0 0 0 0 0 0 - -_0 - - --0 .�- _ 0 _ _0 0 0 0 0 0 0 _ __.. _ .0 0 0 0 0 0 0 .--- --0 80 0 0 48 0 0 - -- _ Q 210 0 20 0 0 0 0 -- -0 ----0--- __ _--__--0 � 247 0 0 0 0 0 0 0 .- _ . _ __0 0 0 0 0 0 0 - -0 32 0 0 48 0 0 - --- 190 0 0 0 0 0 0 0 0- --_ _._ Q..-- 29 -- -- 0 0 0 0 0 0 . -------A- 0 0 0 0 0 0 -- ---- o 57 0 0 1102 0 0 - - - _0 340 0 504 0 0 0 0 --_o - -0- - --_ -6 � _ 803 0 0 0 0 0 - - -- - - 0. 0 0 0 0 0 0 - --0 26 0 0 730 0 0 - -- - 0 169 0 982 0 0 0 0 ----_--o- -_ 0 0.064 0:820 0.600 0.900 0.900 1,080 . 1.270 0.064 0.870 0.870 0.570 0.570 0.570 0.064 1.670 1.670 0.820 0.870 0.570 --- 0.570 0.064 0.900 0.900 0.870 0.870 0.570 0.570 0.570 --0.408-__-_1.59-.-1A9 _--0.049 0.989 ne ne ne ne ne ne -ne ..__. se se se se se se -se- sw sw sw sw sw sw -sw rw nw nw nw nw nw nw nw 1,79 22.96 16.80 0.00 - 0.00 0.00 35.56 1.79 0.00 0.00 15.96 15.96 15.96 -- 15.96 1.79 0.00 46.76 22.96 0.00 15.96 - 15.96 1.79 25.20 25.20 0.00 0.00 15.96 15.96 15.96 0.89 14.90 25.00 0.00 0.00 0.00 �43.03 0.89 0.00 0.00 47.30 36.14 37.73 �37.73 0.89 0.00 15.98 15.21 0.00 20.29 30.55. 0.89 49.12 49.12 0.00 0.00 46.91 46.91 46.91 0 0 0 0 0 0 _..- 0 0 0 0 0 0 0 -- - -0 0 0 0 0 0 0 --- - 60 0 0 0 0 0 0 0 0 0 0 0 0 0 _Q 0 0 0 0 0 0 - ---0 0 0 0 0 0 0 - - -0 60 0 0 0 0 0 0 0 0 0 0 0 0 0 - - -_..0 0 0 0 0 0 0 - 0 0 0 0 0 0 -- ---0 108 0 0 0 0 0 0 -0 __ _I- 0 �T _ _ __166 - -0 _--_--_ . - - - _- P__� C --- F __--- �-_ _ _ ---- 0.48 _0.- .-.27.69 ._.27.69 0.25 0.00 . _0.00 - -0 :.----0 --- - - 54 --- - 0 ----. _4....----� --- 0 - - _ _ 6 _0 ---0 6 c) AED excursion -9 765 Envelope loss(gain 274 44 3495 3022 12 a) Infiltration b) Room ventilation 125 0 34 0 606 0 166 0 13 Internal gains Occupants@ 230 Appliancesrother 0 0 0 0 0 0 Subtotal (Iines6 to 13) 399 78 4101 3188 14 15 Less extemalload Lesstransfer Redistribution Subtotal Dud loads 0% 0% 0 0 -399 0 0 0 0 -78 0 0 0% 0% 0 0 504 4605 0 0 0 163 3351 0 Total room load Air required (dm) 0 0 0 0 T 4605 211 3351 175 Calculations approved byACCAto meet all requirements of Manual J 8th Ed wrigl �tsoft^ 2018-Jul-l7 07:33AO ACC*. Right Suite® Universal 201818.0.16 RSU08101 Page 3 CK\DoamertslWrightsoftHVAC1ARBUCCI,MARIO.rup Calc=MJ8 Front Door faces: SW +�►- wrightsofta Ri ht-J® Worksheet Job. M Date: JUNE 14, 2018 By.' QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax:772-466-6796 Email: QUICKCALCS@,40L.COM 1 2 3 4 5 Room name Exposed wall Room height Room dimensions Room area ELE 0 ft 10.0 It heat/000l 5.0 x 5.0 ft 25.0 ftz GREAT ROOM 72.0 ft 12.0 It heat/oDol 1.0 x 592.0 ft 592.0 ftz Ty Conshucfion number U-value (Btuhltt;oF) Or HTM (Btuh/M Area (ft� or perimeter (ft) Load (Btuh) Area (M or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 11 W 13B-5oorrs 10A-v 1013-v 1A-c1ov IA-c1ov 1A-r1obd 1A-f1omd_--•---T._._ 13B-5oays 1 D-c2om 1 D-c2om 1 D-c2ov 1 D-c2ov 1 D-c2ov 1D-c2ov_-_ _----- --- 13B-5oons - 10A-m 10A-m 10A-v 1D-c2om 1 D-c2ov 1313-5ows 1A-h1ov 1A-h1ov 1D-c2om 1 D- tom 1 D-c2ov 1 D-c2ov 1 D-c2ov 12Ci--0sw_____-__-,-----0.091.. 16X19-0md 22A-tDl -- 0.064 0.820 0.600 0.900 0.900 1.080 _.._1270 0.064 0.870 0.870 0.570 0.670 0.570 0.570 a6i 1.670 1.670 0.820 0.870 0.570 0.064 0.900 0.900 0.870 0.870 0.570 0.570 0.570 0A08 0.989 0.989 ne ne ne ne ne ne _ne- se se se se se se se sw sw 9N 9N sw sw nw nw nw nw nw nw nw nw _ - - 1.79 22.96 16.80 0.00 0.00 0.00 ----3556 1.79 0.00 0.00 15.96 15.96 15.96 __ 15.96 1.79 0.00 46.76 22.96 0.00 15.96 1.79 25.20 25.20 0.00 0.00 15.96 15.96 15.96 -_-2.55-1.28.-----100_--_ 1.59 --0.48 27.69 -_.�27.69 0.89 14.90 25.00: 0.00 0.00 0.00 ___43.03 0.89 0.00 0.00 47.30 36.14 37.73 37.73 0.89 0.00 15.98 '15.21 0.00 20.29 0.89 49.12 49.12 0.00 0.00 46.91 46.91 46.91 0 0 0 0 0 0 _.. _ 0 0 0 0 0 0 0 . _ _ _ 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 _-_ .__0 25 - ---0 0 0 0 0 0 0 _._-_ _ A 0 0 0 0 0 0 _._._ __0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 100-----.255-__--_128,-_ 0 >-----_ _ 0 0 --- - 0 0 0 0 0 0 .._-- Q 0 0 0 0 0 0 _.__- 0. 0 0 0 0 0 0 0 0 0 0 0 0 0 ,- 0 0 -- -- 0 0 - -----0 0 0 0 0 0 0 _-__---. -0 0 0 0 0 0 0 - _--0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 _ 0 0 -- 3 336 0 0 0 0 0 .----_160.. 264 0 0 0 0 0 _- -- 56 0- 0 0 0 0 0 264 0 0 0 0 0 0 _ 42 --_-0.___.-_0,._--_0__----9- 74 - - 90 0 .-� -0. 176 0 0 0 0 .0 __- 0 208 0 0 0 0 0 -_ 20 0 0 0 0 0 0 ---0--------- 222 0 0 0 0 0 0 _ - 0 74 -- -- _ 90 0 _. ---6 315 0 0 0 0 0 _._ 5690 373 0 0 0 0 0 ----894 0 0 0 0 0 0 Q 398 0 0 0 0 0 0 670 117 -- _ -43 0 -- - -0 157 0 0 0 0 0 . _ .. 6nA 185 0 0 0 0 0 --.._._2113 0 0 0 0 0 0 -- 0 197 0 0 0 0 0 0 1970 110 - -_ -23 0 ----- 0 _____ . C F F F---.22A-tpl------ 1.49 _ -0.25 0.00 ---0.00 6 c) AED excursion -14 -1303 Envelope loss/gain 255 115 8500 10336 12 a) Infiltration b) Room ventilation 0 0 0 0 1805 0 494 0 13 Internal gains: Ooaupants@ 230 Appliances/other 0 0 0 0 0 0 Subtotal (lines6 to 13) 255 115 10305 10831 14 15 Less external load Less transfer Redistribution Subtotal Ductloads 0% 0% 0 0 -255 0 0 0 0 -115 0 0 21% 16% 0 0 0 10305 2199 0 0 0 10831 1784 Total room load Air required (dm) 0 0 0 0 12504 572 12615 659 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. -4*- wrigF�tsof_t^ 2018-Ad-1707:33:40 ACC'O" Right-SdteO Uriversal 2018 18.0.16 RSU08101 Page 4 CK1Doamerts\WrigttsoftHVACWRBUCCI,MARIO.rLp Calc=MJ8 Front Door faces: SW -�+ wrightsoft9 h1 t-J® Worksheet JobM. UNDate: JUNE 14, 2018 By: QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM 1 2 3 4 5 Room name Fposed wall Room height Room dimensions Room area STAIRWAY 25.0 ft 12.0 ft heat/000l 1.0 x 251.0 ft 251.0 T KrrCHEN 15.0 It 12.0 It heat/cool 20.0 x 15.0 ft 300.0 ft2 Ty Construclion number U-value (Btuhftt2---F) Or HTM (Btuh/ft2) Area (T) or perimeter (ft) Load (Btuh) Area (ft-) or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross NIPS Heat Cool 6 11 ---- 13'13�vs. 5a----- 10A-v 1013-v IA-c1ov AA-c1ov 1A-r1obd 1313-5ooNs 1 D-c2om 1 D-c2om 1 D-c2ov 1 D-c2ov 1 D-c2ov 1 D-c2ov .-. ,._ 136-5ootis 10A-m 10A-m 10A-v 1 D-c2om 1 D-c2ov - _1D_c2ov --.- 1313-5coNs 1A-h1ov 1A-h1ov 1 D-c2om 1 D-c2om 1 D-c2ov 1 D-c2ov 1 D-c2ov .16X19-Omd _-- 22A-tpl . __ _ _ - 0.064 0.820 0.600 0.900 0.900 1.080 0.064 0.870 0.870 0.570 0.570 0.570 _r --_WRO 0.064 1.670 1.670 0.820 0.870 0.570 ,M 0:570 0.064 0.900 0.900 0.870 0.870 0.570 0.570 0.570 OA08 -- 0..049 Y 0.989 ne ne ne ne ne ne se se se se se se sw sw sw sN sm sw _snr nw nw nw nw nw nw nw nw _-'_--2.55 _� . -- - -_. 1.79 22.96 16.80 0.00 0.00 0.00 1.79 0.00 0.00 15.96 15.96 15.96 1.79 0.00 46.76 122.96 0.00 15.96 __ 15:96 1.79 25.20 25.20 0.00 0.00 15.96 15.96 15.96 - _-1.59 ------0.48. 27.69 _._.. �.__. - 0.89 14.90 25.00 0.00 0.00 0.00 0.89 0.00 0.00 47.30 36.14 37.73 0.89 0.00 15.98 15.21 0.00 2029 _30,55- 0.89 49.12 49.12 0.00 0.00 46.91 46.91 46.91 , 1.28 1A9 " 0.25 0.00 -._. _... .----0 0 0 0 0 0' 0 0 0 0 0 0 0 0 0 0 0 0 -- --- _ Q 300 0 0 0 0 0 24 0 ,_. 0 0_ __- _56 0 ._-.--_---- --- - 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 -- 0 276 0 0 0 0 0 0 0 _ 0. __. -- -._--_56 -.--._ 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 -- _-- 0 495 0 0 0 0 0 383 0 "-_0 _ _ 0 _27 0 -_- .._... -•.---_-Q ----_O 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 -0 246 0 0 0 0 0 1126 0 -____Q 0 _ 14. 0 ------- _ 0 O 0 0 0 0 0 180 0 0 0 18 0 0 0 0 0 0 0 0 .,-- 9 0 0 0 0 0 0 0 _0 o. ------ 6---- 0 0 0 0, 0 162 0 0 0 7 0 0 0 0 0 0 0 0 -- --_ 0 0 0 0 0 0 0 0 _--__ 0 ,__0 0 `--225 0 -_-__-. O 0 0 0 0 0 290 0 0 0 287 0 0 0 0 0 0 0 0 0.. 0 0 0 0 0 0 0 -__-_ 4 0 ------ -0 0 0 0 0 0 144 0 0 0 650 0 ----__._- _ 0 0 0 0 0 0 0 _-----9 0 0 0 0 0 0 0 _ - - 0 -0 - ------0- ----- 57_ _.�._ 0 ------- 0 -__ . C-- _ _ F19C_19cscp- F 0 _0 - - 0 -----107_ 0 -_. _-_ -_- ---225 0 6 c) AED exajrsion 282 13 Envelope loss(gain 904 1668 685 865 12 a) Infiltration b) Room ventilation 627 0 172 0 376 0 103 0 13 Internal gains Occupants@ 230 Appliances/other 0 0 0 0 0 2000 Subtotal (lines 6to 13) 1531 1839 10611 2968 14 15 Less external load Less transfer Redistribution Subtotal Dud loads 21% 16% 0 0 9 1540 329 0 0 4 1844 304 21% 16% 0 0 0 1061 226 0 0 0 2968 489 Total room load Air required (dm) 1868 86 2147 112 1591 1287 3457 180 Calculations approved bVACCA to meet al I requirements of Manual J 8th Ed. _ # wrightso_fta 2018-Jul-1707:33:40 Right -Suite® Universal 201818.0.16 IRS U08101 Page 5 '��`...CK\Doamerts\WrightsoftWACWRBUCCI,MARIO.rup Calc=MJ8 Front Door faces: SW wrightsoft° Right-M Worksheet Job: UNIT 1 Date: JUNE 14, 2018 By: QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@,AOL.COM 1 2 3 4 5 Room name E>posed wall Room height Room dimensions Room area LAUNDRY 9.0 ft 12.0 ft heat/000l 1.0 x 82.0 It 82.0 tt2 BEDROOM4 28.0 It 12.0 ft heat/oDol 1.0 x 204.0 it 204.0 it' Ty Construction number U-value (BtuhW--F) Or HTM (Btuhtfl Area (ft-) or perimeter (ft) Load (Btuh) Area (fF) or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 11 m 13B-5oc s----- 10A v 1013-v IA-c1ov 1A-c1ov 1A-r1obd 1A,r1omd__---- 1365oom 1 D-c2om 1 D-c2om 1 D-c2ov 1D-c2ov 1 D-c2ov 1DQo_v_p_M __--_- 13B-5ooA5 10A m 10A-m 10A-v 1DQom 1 D-c2ov ,1Dc2oy 1313-5ocws 1A-hlov 1A-hlov 1D-c2om 1 D-c2om 1 D-c2ov 1 D-c2ov 1 D-c2ov 12C Osw_-� 16X19-0md- ?ZA-tpl - - -- -2267tpl.._ _-• - . - _ _-_-0.064 0.820 0.600 0.900 0.900 1.080 _- 1.270 0.064 0.870 0.870 0.570 0.570 0,570 .-_.__.0_570 0.064 1.670 1.670 0.820 0.870 0.570 0.570 0.064 0.900 0.900 0.870 0.870 0.570 0.570 0.570 -- - _ Q091-_ 0408 --0049. - - 0.989 _ 0.989 ne ne ne ne ne ne _ne_ se se se se se se se_ sw sw sw sw sw sw _4sw_ nw nw nw nw nw nw nw nw _ _ ✓ �_ _� --1.79 22.96 16.80 0.00 0.00 0.00 _35.56. 1.79 0.00 0.00 15.96 15.96 15.96 15.96 1.79 0.00 46.76 22.96 0.00 15.96 15.96 1.79 25.20 25.20 0.00 0.00 15.96 15.96 15.96 -w- ---2.55 1.59 0.48 -27,69 _-27.69 0.89 14.90 25.00 0.00 0.00 0.00 __4-3.03. 0.89 0.00 0.00 47.30 36.14 37.73 37773 0.89 0.00 15.98 15.21 0.00 20.29 ---30.55 0.89 49.12 49.12 0.00 0.00 46.91 46.91 46.91 _----_-_ 1.28 ---!Al _9.25 _ _ 0_00_ --__._0.:90. _ 0_..0 '0 0 0 0 0 -----0_ 108 0 0 0 0 14 --- 0 0 0 0 01 0 0 -_ 0 0 0 0 0 0 0 0 ----0 ____ 0 - _82_21. -- 0 _--0 0 0 0 0 0 -_-0 94 0 0 0 0 5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 -----0 _ _ 0 .- --- _. - 0. ..-----__ 0 0 0 0 0 0 ----__-0 o 0 0 0 0 0 .------_ 0 84 0 0 0 0 528 -_ 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 o 0 0 0 0 0 _-- 0. 168 0 0 0 0 0 o 0 0 0 0 0 --- Q 168 0 0 0 0 0 _--_ a 0 0 0 0 0 ----0 301 0 0 0 0 0 -.--- 0 206 0 1870 0 0 80 0 0 0 0 0 0 0 0 -------- _ - ..-- - -0. _-__-- 53 o 0 0 0 0 0 -.--0 149 0 0 0 0 0 ---- _ 0 102 0 639 0 0 101 0 0 0 0 0 0 0 0 -----_0 --- 0 . - -- 0 _-_ . 168 0 0 0 0 223 _ _-.- 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 --- _-__-_ -----0 _ _ _ 0 --- _..,._ -_0 _._-.-- 168 0 40 0 0 5 0 0 0 0 0 0 0 0 __.- _.. 115 0 40 0 0 5 0 0 0 0 0 0 0 0 _ _ ------------ _PT C _-_ F - .-_ -F ----- ------0 0 -- -- 0 -0 -- -------Q ---v 0 -- - --0 . - 4 ------ - -- 0 - -- Q . - .- -._ .2 6 c) AED excursion 195 413 Envelope loss/gain 431 828 27291 1698 12 a) Infiltration b) Room ventilation 226 0 62 0 702 0 192 0 13 Internal gains: Oooupants@ 230 Appliances(other 0 0 0 1 230 0 Subtotal (lines 6 to 13) 657 890 3431 2120 14 15 Less e)demal load Less transfer Redistribution Subtotal Ductloads 21% 16% 0 0 0 657 140 0 0 0 890 147 21% 16% 0 0 1 3431 732 0 0 0 2120 349 Total room load Air required (dm) 1 797 36 10361 54 4164 191 2470 129 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. wrights_oft 2018-Jul-l7 07:33AO - Right-Sute®Uriversal 201818.0.16 RSU08101 Page 6 CK1DoameriMWrigtLoftHVAC1ARBUCCI,MARIO.rup CaIc=MJ8 Frort Door faces: SW - wrightsoft® Right-J® Worksheet Job: UNIT % Date: JUNE 14, 2018 By: QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466-6796 Email: QUICKCALCS@AOL.COM 1 2 3 4 5 Room name Exposedwall Room height Room dimensions Room area ELEVATOR 0 It 12.0 it heaVcool 5.0 x 5.0 it 25.0 ftz BATH 4 9.0 ft 12.0 ft heaV000l 5.0 x 13.0 it 65.0 ftz Ty Constudion number U-value (BtuhAt-'F) Or HTM (Btuh/ft� Area (ftl or perimeter (ft) Load (Btuh) Area (ftl or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 11 W 1313-500Hs 10A-v 108-v 1A-olov 1A-clov IA-rlobd 1313-500AS 1D-c2om 1 D-c2om 1 D-c2ov 1 D-c2ov 1 D-c2ov _1D_c2ov_._ 136 5ooAs 10A-m 1oA-m 10A-v 1 D-c2om 1 D-c2ov 13B-50ays 1A-h1ov 1A-hlov 1 D-c2om 1 D-c2om 1 D-c2ov 1 D-c2ov 1 D-c2ov- - 12C:.Q -- - 16X19-0md-_---_---•- 22A-WI--- - - - 0.064 0.820 0.600 0.900 0.900 1.080 0.064 0.870 0.870 0.570 0.570 0.570 -_ _. 0.570 0.064 1.670 1.670 0.820 0.870 0.570 0.064 0.900 0.900 0.870 0.870 0.570 0.570 0.570 0.091 ___-- 0A08 --- 0.989 ne ne ne ne ne ne se se se se se se _se_ sw sw sw sry sry sw nw nw nw nw nw nw nw nw 1.79 22.96 16.80 0.00 0.00 0.00 1.79 0.00 0.00 15.96 15.96 15.96 _ _._15:96 1.79 0.00 46.76 22.96 0.00 15.96 1.79 2520 25.20 0.00 0.00 15.96 15.96 15.96 - -2.55 1:5@_.. -27.69 -- 27.69 0.89 14.90 25.00 0.00 0.00 0.00 0.69 0.00 0.00 47.30 36.14 37.73 -.37.73 0.89 0.00 15.98 15.21 0.00 20.29 0.89 49.12 49.12 0.00 0.00 46.91 46.91 46.91 _-_1.26: 1__49 025 - 0.00 -0.0.0 0 0 0 0 0 0 0 0 0 0 0 0 _. _. _._0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 -- - 0 -.._a _---_ 25. _ -- 0 - - 0 0 0 0 0 0 0 0 0 0 0 0 0 _.._ 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 -------0 _ _ 4.,_-__--Q _25 - -. 4 - --- - 8 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 - - ---,---12 - -0 - -- 0 0 0 0 0 0 0 0 0 0 0 0 0 . __._. _.._-0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 - ----0 -------0 - -- - 6 - -- 0 - ------0 0 0 0 0 0 0 0 0 0 0 0 0 _-_ -_. 0 60 0 0 0 0 0 48 0 0 0 0 0 0 0 --- -0 --------0 _ -.-- 60 - -0 - - _ 5. 0 0 0 0 0 0 0 0 0 0 0 0 .-0 52 0 0 0 0 0 5 48 0 0 0 0 0 0 0 _ - -0 - - -- -0 --60 --- - 0 ------ 0 0 0 0 0 0 0 0 0 0 0 0 __--_-- 0. 93 0 0 0 0 0 -----128 86 0 0 0 0 0 0 0 --- -0 0 - --29 - - -0 0 0 0 0 0 0 0 0 0 0 0 0 0 46 0 0 0 0 0 _----- 244. 43 0 0 0 0 0 0 0 - --0 ..__----0 -- - 15 -- - _ 0 __ -.•-_ P-- - _C F - -- F -_- _. 6 c) AED excursion -1 133 Envelope loss/gain 12 6 355 482 12 a) Infiltration b) Room ventilation 0 0 0 0 226 0 62 0 13 Internal gains: Occupants@ 230 Appliances/other 0 0 0 0 0 0 Subtotal (lines6 to 13) 12 6 580 544 14 151 Less external load Lesstransfer Redistribution Subtotal Duct loads 21% 16% 0 0 -12 0 0 0 0 -6 0 0 ' 21% 16% 0 0 4 584 125 0 0 2 546 90 Total room load Airrequired (dm) 0 0 0 0 1321 709 635 33 Calculations awroved bvACCAto meet all reauirements of Manual J 8th Ed. -F wrigF�tsoTt^ 201 8-Jd-1 7 07:33.40 M Rigtt-SUteOUriversa12018 18.0.16 RSU08101 Page 7 CK\Doamerts\WrightsoftHVACWRBUCCI,MARIO.nip Calc=MJ8 Front Door faces: SW - wrightsoft, Right-J® Worksheet Job: UNIT 1 Date: JUNE 14, 2018 QUICK CALCS, INC. By. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax:772-466-6796 Email: QUICKCALCS@AOL.COM 1 2 3 4 5 Room name Exposed wall Room height Room dimensions Room area POWDER 18.0 ft 12.0 It heat/000l 9.0 x 9.0 It 81.0 ft 20.0 A/C 2 0 It 12.0 ft heat/000l 4.0 x 5.0 It It' Ty Construcion number U-value (Btuhlfl;°F) Or HTM (Btuh/F) Area (fF) or perimeter (ft) Load (Btuh) Area (ft� or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 11 _ � 1313-5o ws,---' 1OA-v 1013-v 1A-clov 1A-cloy 1A-rlobd 1A-r1omd_-.-._._._. 13B5ocws 1 D-c2om 1 D-c2om 1D-c2ov 1DQov 1 D-c2ov 1D-c2ov_ 10Xrn 10A-m 10A-v 1 D-c2om 1Dr2ov 1D_-c2ov_` ___-_-- 1313-5ooAs 1A-h1ov 1A-hlov 1 D-c2om 1 D-c2om 1 D-c2ov 1 D-c2ov 1D-c2ov 12C«Osw -_ -- 0.064 0.820 0.600 0.900 0.900 1.080 ------1-2Z0 0.064 0.870 0.870 0.570 0.570 0.570 0.570 0.064 1.670 1.670 0.820 0,870 0.570 -- 0.570 0.064 0.900 0.900 0.870 0.870 0.570 0.570 0.570 0:091 _0.408 0.0491- 0.989_= - __0989 ne ne ne ne ne ne -_ne_ se se se se se se se sw sw sw sw sw sw _-sw..__ nw nw nw rrw nw nw nw nw -_ _= . 1.79 22.96 16.80 0.00 0.00 0.00 ---;35.56 1.79 0.00 0.00 15.96 15.96 15.96 -_ 15.96 1.79 0.00 46.76 22.96 0.00 15.96 15.96 1.79 25.20 25.20 0.00 0.00 15.96 15.96 15596 -_..2.55 1.59 27.69 27.69 0.89 14.90 25.00 0.00 0.00 0.00 r-_43.03 0.89 0.00 0.00 47.30 36.14 37.73 37.73 -- 0.89 0.00 15.98 15.21 0.00 20.29 ; 30.55- 0.89 49.12 49.12 0.00 0.00 46.91 46.91 46.91 _- _1.28 -1.49 0.00 _..-O.OQ - 0 0 0 0 0 0 --.__0. 0 0 0 0 0 0 0. 008 0 0 0 0 0 0: 108 0 0 0 0 8 0 0 _ 9. ,- _ 0 0 ._-_.._-_64,---- o 0 0 0 0 0 0 0 0 0 0 0 0 T - 108 0 0 0 0 " 0 _ _ 0 100 0 0 0 0 0 0 0 __0 -_ 0 0 o 0 0' 0 0 0 -0--0 0 0 0 0 0 0 _ 0 194 0 0 0 0 0 0 179 0 0 0 0 128 0 0 --- - - Q 0 0- o 0 0 0 0 0 --- --0 0 0 0 0 0 0 0 --- 96 0 0 0 0 0 .-- .-0 89 0 0 0 0 375 0 0 ._ -_-._ 0 0 0 O 0 0 0 0 0 ---- o 0 0 0 0 0 0 0 --' - 0 0 0 0 0 0 -___--0 _--- a 0 0 0 0 0 ----0 0 0 0 0 0 0 0 ------ o 0 0 0 0 0 --- -- 0 0 0 0 0 0 0 _ -_ 0 0 0 0 0 0 0 --_.----0 0 0 0 0 0 0 0 0 ----- -0 _ 0 0 0 0 0 0 0 --- -- Q 0 0 0 0 0 0 -__ 0 6 0 0 0 0 0 --._----9 0 0 0 0 0 0 0 0 ----- --0 _ 0 __-__0 _ -L----G- P - - 0 0 0 0 0 0 - ._a. Q 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 .-. --0 _- 0 ----0 0 C F .F_-.--._ 16X19-Omd ,22&tpl_-______-_-- 0 0 0 6 c) AED excursion 82 0 Ernelope loss(gain 899 645 2 1 12 a) Infiltration b) Room ventilation 451 0 124 0 0 0 0 0 13 Internal gains Occupants@ 230 Appliances/other 0 0 0 0 0 0 Subtotal (lines6 to 13) 1350 768 2 1 14 15 Less external load Less transfer Redistribution Subtotal Dudloads 21% 16% 0 0 1 1351 288 0 0 0 769 127 21% 16% 0 0 -2 0 0 0 0 -1 0 0 Total room load Air required (o5n) 1639 75 896 47 0 0 0 0 Calculations approved byACCAto meetall requirements of Manual J 8th Ed. _ - wrfghtsoit^ 201 8-Jul-1 7 07:33AO Right-Sute®Udversa1201818.0.16RSU0B101 Page 'CC-i`...CK1Docments\WrigttsoftHVAC1ARBUCCI,MARIO.rup Calc=MJ8 Frorl Door faoes: SW wrightsoft° Right-J® Worksheet Job: UNIT 1 Date: JUNE 14, 2018 By: QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466-6796 Email: QUICKCALCS@AOL.COM 1 2 3 4 5 Room name Exposed wall Room height Room dimensions Room area STORAGE 5.0 ft 10.0 ft heat/000l 9.0 x 5.0 ft 45.0 ft' Ty Construdion number U-value (Btuh/F--°F) Or HTM (Btuhtft Area (ft2) or perimeter (ft) Load (Btuh) Area or perimeter Load Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 11 V 1313-'5oons 10A-v 1013-v 1A-clov IA-clov 1A-r1obd _1A:r1omd-_.--� 13B-500AS 1 D-c2om 1 D-c2om 1 D-c2ov 1 D-c2ov 1 D-c2ov 1 D-c2ov --_n 1313-500AS 10A-m 10A-m 10A-v' 1 D-c2cm 1Dr2ov 1Q-jc2o% 13B-5ooNs 1A-h1ov 1A-h1ov 1 D-c2om 1 D-c2om 1 D-c2ov 1 D-c2ov 1 D-c2ov 16X19-0md 19C _19csc;_ -_ 22A-ipl 0.064 0.820 0.600 0.900 0.900 1.080 - 1.270 0.064 0.870 0.870 0.570 0.570 0.570 - 0.570 0.064 1.670 1.670 0.820 0.870 0.570 - _0.570 0.064 0.900 0.900 0.870 0.870 0.670 0.570 0.570 _---0091. _- 0A08 0.049 0.989 ____-_0969 ne ne ne ne ne ne __ne- se se se se se se _ Se_ sw 9N sN sent 9N 9N . sw nw nw nw nw nw nw nw nw __ , _- - _r_ 1.79 22.96 16.80 0.00 0.00 0.00 1.79 0.00 0.00 15.96 15.96 15.96 _ 15,96 1.79 0.00 46.16. 22.96 0.00 15.96 ___ 15.96 1.79 25.20 25.20 0.00 0.00 15.96 15.96 15.96 ____ 2.55 - 1.59 _ - 0.48 27.69 _,_, 27.69 0.89 14.90 25.00 0.00 0.00 0.00 0.89 0.00 0.00 47.30 36.14 37.73 _ 37.73 0.89 0.00 15.98 15.21 0.00 20.29 _30.55. 0.89 49.12 49.12 0.00 0.00 46.91 46.91 46.91 --._1.20. _ JA9 _025: 0.00 - 0.0Q 0 0 0 0 0 0 " 0 0 0 0 0 0 0 0 0 0 0 0 -- -- 0 0 0 0 0 0 0 --__..:0. 50 0 0 0 0 0 0 0 -----_0 -. 0 5 0 0 0 - 0 0 0 0 0 0 0 0 0 - - 0 0 .0 0 0 0 0 _ _- __Q_--__-- 90 0 0 0 0 0 0 0 0. -_. 0 138 0 0 0 0 0 0 0 0 0 0 0 0 --- 0 0 0 0 0 0 0 44 0 0 0 0 0 0 0 _ -- 0 _ -_-__ 0 0 --- -- -..__._ _ - -- - --- ----. - --- ----- - -- --- -- _ 0 0 0 0 0 0 ^ - 0 0 0 0 0 0 0 0 ---- - - 50 0 0 0 0 0 0 0 _-_ _0 -__-_ 0_ 45 --__ 0 G -^ C _ - -F F 6 c) AED exausion -8 Ernelope loss(gain 228 37 12 a) Infiltration b) Room ventilation 104 0 29 0 13 Internal gain& Ooupants@ 230 Applianoeslother 0 0 0 Subtotal (lines6to13) 333 65 14 15 Less extemalload Lesstransfer Redistribution Subtotal Dud loads 21% 16% 0 0 150 482 103 0 0 29 95 16 Total room load Air required (dm) 585 27 110 s Calculations approved bVACCAto meet all requirements of Manual J 8th Ed. _ wrigFrtsoft- 201 8-JLJ-1 7 07:33:40 Right SUte® Universal 2018 18.0.16 RSU08101 Page 9 'CCI�`...CK\DoamertslWrightsoftWACWRBUCCI,MARIO.rup Calc=MJ8 Front Door faces: SW - wrightsoft° Ri ht-J® Worksheet Job: VVI% 2 Date: JUNE 14, 2018 By: QUICK CALCS, INC. 317 ST. LUCIE LN., Fr.. PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466-6796 Email: QUICKCALCS@,AOL.COM 1 2 3 4 5 Room name E)qoosed wall Room height Room dimensions Room area UNrr 2 189.9 It 10.0 ft d 1765.0 ftz MASTER BATH 36.0 It 10.0 It heat/Oool 1.0 x 200.0 It 200.0 ft2 Ty Construction number U-value (BtuhAF--°F) Or HTM (Btuhflt2) Area (M or perimeter (ft) Load (Btuh) Area (ft2) or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 11 �- 1313-5ooAs - - -- 10A-v 1013-v 1A-c1ov IA-c1ov 1A-r1obd 1A-r1omd- -- - 13B-5oays 1 D-c2om 1 D-c2om 1 D-c2ov 1 D-c2ov 1 D-c2ov 1D-c2ov --- - 36-5ocAs 10A-m 10A-m 10A-v 1 D-c2om 1 D-c2ov 1Dt2ov__---- 138-5oons 1A-h1ov 1A-hlov 1DQom 1D4om 1 D-c2ov 1 D-c2ov 1 D-c2ov -_ _.-- -_ -_-._- _ 12C-0sw ----� 16X19-0md 22A-tpl 22A-WI --- --- -----0.064 0.820 0.600 0.900 0.900 1.080 --- 1.270 0.064 0.870 0.870 0.570 0.570 0.570 -- 0.570 0.064 1.670 1.670 0.820 0.870 0.570 -0.570 0.064 0.900 0.900 0.870 0.870 0.570 0.570 --_.- 0.570 --- _. 0 091 OA08 0.049 0.989 . _- _0.989 ne ne ne ne ne ne -.ne- se se se se se se -se- sw sN sw sw sw sw aA nw nw nw nw nw nw nw nw --- -_- - - - =- 1.79 0.00 0.00 25.20 25.20 30.24 -- 0.00 1.79 24.36 24.36 0.00 0.00 0.00 -- -0-00 1.79 46.76 0.00 0.00 24.36 0.00 ----0.00 1.79 0.00 0.00 24.36 24.36 0.00 0.00 0.00 _- --- -- 0.00 1.59 --_ 0.00 -ADO ---27.6.9 -- 0.89 0.00 0.00 57.34 57.34 40.18 ------ 0.00- 0.89 43.38 43.38 0.00 0.00 0.00 -- 0-Q8 0.89 42.20 0.00 0.00 43.38 0.00 ---0.00 0.89 0.00 0.00 58.95 58.95 0.00 0.00 0.00 - 0.00 1.49 __... _0.00 0.00 ---- 0.00 - 280 0 0 18 24 80 - ----- ,Q 670 50 20 0 0 0 -- 0 280 80 0 0 20 0 ------0 670 0 0 10 20 0 0 0 ._. - _ _-. _ 0 1765 - - 158 0 0 0 0 0 - - __ 600 25 10 0 0 0 --- - 0 180 4 0 0 10 0 - - 640 0 0 0 0 0 0 _ 0 - - - � 1765 - - 0 0 --- 37 -283 0 0 454 605 2419 -- _.- 0 1075 1218 487 0 0 0 - - 0 323 3741 0 0 487 0 -- - -0 1147 0 0 244 487 0 0 .0 - _-.-_- -- - -0 2798 ---0 0 ---J-033- - - 141 0 0 1032 1376 3214 - - __0 534 2169 868 0 0 0 ------0 160 3376 0 0 868 0 ---- 0 569 0 0 589 1179 0 0 0 . _ - -- _ -_ - - 0 2623 -- - -0 0 -- - --0 -- -140 0 0 18 24 0 - ----0 60 0 0 0 0 0 - -_0 0 0 0 0 0 0 - -- - 0 160 0 0 0 0 0 0 0 -- --._._ -- _ _ 0 200 --- 0 0 - --14 - -98 0 0 0 0 0 - -- 0 60 0 0 0 0 0 - -- - - 0 0 0 0 0 0 0 - 0 160 0 0 0 0 0 0 0 .__ -. --. - --0 200 _. _ --0 0 - --176 0 0 454 605 0 - ----0 108 0 0 0 0 0 0 0 0 0 0 0 - - - 287 0 0 0 0 0 0 _ 0 - 0_0 317 --- ---- -0 0 - 87 0 0 1032 1376 0 ... -- - 0 53 0 0 0 0 0 0 0 0 0 0 0 -- - ---0 142 0 0 0 0 0 0 0 297 - 0 0 G - ------ . _---- P -_-- C F F- - -.0 0 - --2.1.9- 6 c) AED excursion 0 -369 Envelope loss/gain 16800 18698 2015 2620 12 a) Infiltration b) Room ventilation 3969 0 1087 0 752 0 206 0 13 Internal gains Occupants@ 230 Applianoes/other 0 0 0 0 0 0 Subtotal (lines6 to 13) 20T70 19785 2767 2826 14 15 Less external load Lesstransfer Redistribution Subtotal Ductloads 21% 16% 0 0 0 20770 4460 0 0 0 19785 3084 21% 16% 0 0 0 2767 594 0 0 0 2826 441 Total room load Air required (cf n) 25230 1200 22869 1200 1 3361 160 3266 171 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. _ wrGghtso_Tt^ 2018-Jul-1707:33:40 Right -Suite ® Universal 201818.0.16 RSU08101 Page 10 CK1Doomerts\WrightssoftHVAC1ARBUCCI,MARIO.rLip Calc=MJ8 Frort Door faces: SW - wrightsoft Right-J® Worksheet Job: UNIT 2 Date: JUNE 14, 2018 By: QUICK CALLS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax. 772-466-6796 Email: QUICKCALCS@,40L.COM 1 2 3 4 5 Room name Exposed wall Room height Room dimensions Room area TOILET 4.0 ft 10.0 ft heat/cool 6.0 x 4.0 It 24.0 1F M WIC 12.0 It 10.0 ft heat/cool 1.0 x 83.0 It 83.0 fF Ty Construction number U-value (Btuh/11--9 Or HTM (Btuhdl) Area (n or perimeter (ft) Load (Btuh) Area (n or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 11 0 0 0 0 0 0 0 0 0 0 0 0 0 0- -- - 0 0 0 0 0 0 __-o- 0 0 0 0 0 0 0 - 1313=5ooAs' 10A-u 1013-v IA-c1ov 1A-c1ov 1A-r1obd 1A-0omd -. 13B-5ooAs 1 D-c2om 1 D- tom 1 D-c2ov 1 D-c2ov 1 D-c2ov 1 D-c2ov - 0.064 0.820 0.600 0.900 0900 1.080 1,27.0 0.064 0.870 0.870 0.570 0.570 0.570 0.570 -ne ne ne ne ne ne -ne_ se se se se se se se 1.79 0.00 0.00 25.20 2520 30.24 _.000 1.79 24.36 24.36 0.00 0.00 0.00 0.00 0.89 0.00 0.00 57.34 57.34 40.18 0.00 0.89 43.38 43.38 0.00 0.00 0.00 0.00 - 0 0 0 0 0 0 0 _ 0 0 0 0 0 0 0 0 0 0 0 0 0 _--_-�.- 0 0 0 0 0 0 ---0 0 0 0 0 0 0 0 _ .0 0 0 0 0 0 0, = . - 0 0 0 0 0 0 0 ----0- 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0---- _ 0 0 0 0 0 0 0-- 0 0 0 0 0 0 0 _ -. 13B-500AS - 10A-m 10A-m 10A-v . 1 D- tom 1 D-c2cv 1 D_-c2ov 136-50CAS 1A-hlov 1A-hiov 1 D-c2om 1 D-c2om 1 D-c2ov 1 D-c2ov 1D-c2ov ---- --_ 16X19-0md 19G19cscp,__- 0.064 1.670 1.670 0.820 0.870 0.570 0.570 0.064 0.900 0.900 0.870 0.870 0.570 0.570 _ 0.570 0.408 --.-0.049 siv sw sw sw sw sw _sw nw nw nw nw nw nw nw _nw - 1.79 46.76 , 0.00 0:00 24.36 0.00 .-0.00 1.79 0.00 0.00 24.36 24.36 0.00 0.00 _ 0.00 -._0.00 1.59 ---0.00 0.89' 42.20 0.00 • 0.00 43.38r0 0.00 0.00- 0.89 0.00 0.00 58.95 58.95 0.00 0.00 - 0.00 0.00 1.49 0.00 0 0 0 0 0 40 0 0 10 0 0 0 ^ --- 0 _ ---_0 24 0 0 0 0 0 0 0 30 0 0 0 0 0 0 -- - - ---_0 24 .,�0 0- 0 0 0 0 0 54 0 0 244 0 0 0 _-- -- 0 38 _ _0 0 0 0 0 0 0 _._p 27 0 0 589 0 0 0 0 0 0 0 0 0 0 120 0 0 0 0 0 0 - _0 83 -.-__0 _ 0 0 0 0 0 0 0 ____0 ' 120 0 0 0 0 0 0 - --- 0 83 ;�---0 __ 0 0 0 0 0 0 0 Q _ T 0 0 0 0 0 0 ____o 107 0 0 0 0 0 0 --- 0 123 _-40. -- -_ 0 _� _! 215 0 0 0 0 0 0 _ -- 0 132 -0. _ _ _ _0 C ---- 36 __-0 0 6 c) AED excursion 143 -34 Envelope loss(gain 335 795 347 196 12 a) Infiltration b) Room ventilation 84 0 23 0 251 0 69 0 13 Internal gains: Occupants@ 230 Appliancestother 0 0 0 0 0 0 Subtotal (lines 6 to 13) 419 818 1597 264 14 15 Less external load Lesstransfer Redistribution Subtotal Duo:loads 21% 16% 0 0 0 419 90 0 0 0 818 127 21% 16% 0 0 185 782 168 0 0 84 348 54 Total room load Air required (dm) 509 24 945 50 950 45 403 21 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. _ - wrGghtso_Tt d S2018-Jul-1707:33:40 Ngtute®Udversa12018 18.0.16 RSU08101 Page 11 '��`...CKDoameNs\WrigttsoftWACWRBUCCI,MARIO.nip Calc=MJ8 Front Door faces: SW -rF wrightsoftm Right-J® Worksheet Job: UNIT 2 Date: JUNE 14, 2018 By: QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466-6796 Email: QUICKCALCS@,AOL.COM 1 Room name WIC WIC 2 2 Exposed wall 0 it 6.0 It 3 Room height 10.0 It heat/cool 10.0 ft heat/oDol 4 5 Room dimensions Room area 8.0 x 6.0 It 48.0 ft= 7.0 x 6.0 It 42.0 fP Ty Construclion U-value Or HTM Area (M Load Area (fL2) Load number (Btuh/fP--°F) (Btuh/ft) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 W 1313-5ocAs 0.064 ne 1.79 0.89 0 0 0 0 0 0 0 ` 0 10A-v 0.820 ne 0.00 0.00 0 0 0 0 0 0 0 0 1013-v 0.600 ne 0.00 0.00 0 0 0 0 0 0 0 0 1A-clov 0.900 ne 25.20 57.34 0 0 0 0 0 0 0 0 11 1A-clov. IA-rlobd 0.900 1.080 ne ne 25.20 30.24 57.34 40.18 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1.270._ne_-..'Q.00._�0.0.0.-____.0v_--_e_0. 0_. Q___ ___..1A-r1omd__,__._._-__ 13B-5ocArs 0.064 se 1.79 0.89 0 0 0 __ 0 60 --0 66 ---.0 108 _0 53 1 D-c2om 0.870 se 24.36 43.38 0 0 0 0 0 0 0 0 1 D- tom 0.870 se 24.36 43.38 0 0 0 0 0 0 0 0 1DQov 0.570 se 0.00 0.00 0 0 0 0 0 0 0 0 1 D-c2ov 0.570 se 0.00 0.00 0 0 0 0 0 0 0 0 1 D-c2ov 0.570 se 0.00 0.00 0 0 0 0 0 0 0 0 1D-c2ov 136 5oons __ 0,570 0.064- se sa _-0.00 _ , 1.79 -__0.00 0:8'9 0 0 0 _0 0 �._0 _ _ 0 _-._ _.__0. 0 10A-m 1.670 sw 46.76 42.20 0 0 0 0 0 0 0 0 10A m 1.670 sw 0.06 0.00 0 0 0 0 0 0 0 0 10A-v 0.820 sw, 0.00 0.00 0 0 0 0 0 0 0 0 1 D-c2om 0.870 sw 24.36, 43.38 0 0 A 0 0 0 0 0 1D-c2ov 6.570 sw 0.06 >0.00 0 0 0 0 0 0 0 0 __ _ iD c2ov__ .,�,.___ 136-5ooAs 0.064 nw 1.79 0.89 0 0 0 0 0 0 0 0 1A-hlov 0.900 nw 0.00 0.00 0 0 0 0 0 0 0 0 1A-h1ov 0.900 nw 0.00 0.00 0 0 0 0 0 0 0 0 1 D- tom 0.870 nw 24.36 58.95 0 0 0 0 0 0 0 0 1 D-c2om 0.870 nw 24.36 58.95 0 0 0 0 0 0 0 0 1 D-c2ov 0.570 nw 0.00 0.00 0 0 0 0 0 0 0 0 1 D-c2ov 0.570 nw 0.00 0.00 0 0 0 0 0 0 0 0 1 D-c2ov 0.570 _0091,._- nw 0.00 _._ 0:0.0 0.00 _me__0.00 0 _._.__._ Q 0 0 0 0 0 --0._.____ 0 ___0 0 0:_-_ 0 0 0 _ �__: C .__._ 16X19 Omd 0.408 _ _ 1.59 1.49_ 48 48 _.__ 76 �- --0 67_ ___.___.. 19CE19cscp-.,____ _ 0,049 _- _`- _ __ W 0.00 - , 0.00 0_00 . a_ Q 0 0 _----.- ___ Q 0 - - ---- -71 _ 0 0 ---42 _0 0 -- --42 __ ___ 0 _ - 0 0 _ _-_ .:62 --I--A 22A_tpl______w,_ w_0989 ___27.6_9 _._-0.00 . _ _0-0 _ -- ----- __0.___.-_-0 _ _. -,_0�-- _ _4 _ _ .. .. _.0. 6 c) AED excursion -8 -17 Envelope loss(gain , 76 63 174 98 12 a) Infiltration 0 0 125 34 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants@ 230 0 0 0 0 Applianoes/other 0 0 Subtotal (lines 6to 13) 76 63 299 133 Less external load 0 0 0 0 Lesstransfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 76 63 299 133 15 Dudloads 21% 16% 16 10 21% 16% 64 21 Total room load I i 92 73 1 364 153 Air required (dm) 4 4 17 8 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. + wrGgF�tsoTt 2018-Jul-1707:33:40 - - Right -Suite® Universal 2018 18.0.16 RSU08101 Page 12 CK1Doamerts\WrightsoftHVACWRBUCCI,MARIO.rup Calc=MJ8 Frort Door faces' SW - wrightsoft9 Right-J® Worksheet Job: UNIT 2 Date: JUNE 14, 2018 By: QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466-6796 Email: QUICKCALCS@1OL.COM 1 2 3 4 5 Room name E)posed wall Room height Room dimensions Room area MASTER SUITE 33.9 It 10.0 it heat/000l 1.0 x 415.0 ft 415.0 ttz BEDROOM2 13.0 ft 10.0 ft heaV000l 15.0 x 13.0 ft 195.0 ftz Ty Construction number U-value (Btuhfil?-°F) Or HTM (Btuhlftf) Area (ft� or perimeter (ft) Load (Btuh) Area (ft2) or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 11 W --- 1313-500ms, 10A-v 1015-v 1A-ciov 1A-clov 1A-r1obd IA-riomd-_-._-. 1313-5oom 1 D-c2om 1 D-c2om 1 D-c2ov 1 D-c2ov 1 D-c2ov 1 D1ov - --- - 13B-5ooNs 10A m 10A-m 10A-v 1 D-c2om 1 D-c2ov 1D�2ov-- ---- 136-50ays 1A-h1ov 1A-h1ov 1 D-c2om 1 D-c2om 1 D-c2ov 1 D-c2ov 1 D-c2ov 12C-0swr---- 16X19-0md 22A-tpl,-.m._--.- 0.064 0.820 0.600 0.900 0.900 1.080 _-..-1.270 0.064 0.870 0.870 0.570 0.570 0.570 -0.570 0.064 1,670 1.670 0.820 0.870 0.570 -- 0.570 0.064 0.900 0.900 0.870 0.870 0.570 0.570 0.570 _-0A08 _0989 ne ne ne ne ne ne _ne se se se se se se --� sN sN sN sN sw sN -suv- nw nw nw nw nw nw nw nw -_ _ 1.79 0.00 D:00 25.20 25.20 30.24 - --0.00 1.79 24.36 24.36 0.00 0.00 0.00 - 0-00 1.79 46.76 0.00 0.00 24.36 0.00 .-_ W0.00 1.79 0.00 0.00 24.36 24.36 0.00 0.00 0.00 _-_ 1.59 0.89 0.00 0.00 57.34 57.34 40.18 .�0.00 0.89 43.38 43.38 0.00 0.00 0.00 _- 0 00 0.89 '42.20 0.00 0.00 43.38 0.00 --0.00 0.89 0.00 0.00 58.95 58.95 0.00 0.00 0.00 _ 1.49. 140 0 0 0 0 80 --,-__0 200 20 0 0 0 0 -- - -0 0 01 6, 0 0 0 ----0 0 0 0 0 0 0 0 0 60 0 0 0 0 0 - -p 180 10 0 0 0 0 - --- 6 ( 0 0 0 0 0 - - -- 0 0 0 0 0 0 0 0 0 415 108 0 0 0 0 2419 - - 0 323 487 0 0 0 0 ------ 0. 0 0 0 0 0 0 -- - 0 0 0 0 0 0 0 0 658 0 53 0 0 0 0 3214 -------0 160 868 0 0 0 0 - -._ - -66 0 0 0 0 0 - ---- -0 0 0 0 0 0 0 0 0 - _ _ 617 0 _0 0 0 0 0 0 0 ---- 0 130 0 20 0 0 0 6 ---Q 0 0 0 0 0 - --0 0 0 0 0 0 0 0 0 ,195 0 0 0 0 0 0 0 .--. --0 110 0 10 0 0 0 --- --- 0 6 0 0 0 0 0 ---0 0 0 '0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 -- -- - Q 98 0 868 0 0 0 --- - _6 0 0 0 '0 0 0 -- - - 0 0 0 0 0 0 0 0 _ 290 - 0 -..__.--0 .____----0 197 0 487 0 0 0 0 0 0 0 0 0 0 - -- 0 0 0 0 0 0 0 0 0 -- - P-- -- C -- F ._.._ _- - 195 - 309. -_-_0 0 415 0 -a_ -27.69 -__._0.00 _._._0 -0- 0 --0 - - 0 --- 0 6 c) AED excursion -589 232 Envelope loselgain 3994 4323 993 1487 12 a) Infiltration b) Room ventilation 710 0 194 0 272 0 74 0 13 Internal gains Oocupants@ 230 Appliancesrother 0 0 0 0 0 0 Subtotal (lines6 to 13) 4705 4517 1265 1561 14 15 Less external load Lesstransfer Redistribution Subtotal Duct loads 21% 16% 0 0 0 4705 1010 0 0 0 4517 704 21% 16% 0 0 0 1265 272 0 0 0 1561 243 Total room load Air required (dm) 5715 272 52M 274 1537 73 1805 95 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. -Hr+- wrigFmtsoTt- 2018-Jul-1707:33:40 -^^^•- -, Right Sate® UNversa1201818.0.16 RSU08101 Page 13 CK\Doamerts\WrightsoftHVAC\ARBUCCI,MARIO.nip Calc=MJ8 FrontDoor %ces:SW 1- wrightsoft® Right-J® Worksheet Job: UNIT 2 Date: JUNE 14, 2018 By: QUICK CALCS, INC. 317 ST. LUCIE LN., Fr.. PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466-6796 Email: QUICKCALCS@/10L.COM 1 2 3 4 5 Room name Exposed vvall Room height Room dimensions Room area HALLWAY 7.0 ft 10.0 It heaVcool 1.0 x 228.0 ft 228.0 ftz STAIRWAY. 13.0 It 10.0 ft heat/cool 8.0 x 13.0 ft 104.0 ft' Ty Construction number U-value (Btuhtft-°F) Or HTM (Btuh/ft) Area (ft) or perimeter (ft) Load (Btuh) Area (ft) or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 11 V 1313-5oor5 10A v 106-v IA-c1ov 1A-clov 1A-rlobd 1A-r1omd--- - - - 13B-5ooAs 1 D- tom 1 D-c2cm 1 D-c2ov 1 D-c2ov 1 D-c2ov 13B-5ooros 10A-m 10A-m 10A-v 1 D-c2om 1 D-c2ov 13B-5ocws 1A-h1ov 1A-h1ov 1 D-c2om 1 D-c2om 1 D-c2ov 1 D-c2ov 1D-c2ov - -_ - 16X1_9-0md - - - 0.064 0.820 0.600 0.900 0.900 1.080 - 1.270 0.064 0.870 0.870 0.570 0.570 0.570 --0.570 0.064 1.670 1.670 0.820 0.870 0.570 0.064 0.900 0.900 0.870 0.870 0.570 0.570 _- 0.570 -----OA08 0.989 089 ne ne ne ne ne ne . ,ne-- se se se se se se _se sw sw sw sw sw sw --w-----9.00.. nw nw nw nw rtw nw nw nw - -- __- 1.79 0.00 0.00 2520 25.20 30.24 --0.00 1.79 24.36 24.36 0.00 0.00 0.00 - 0-00 1.79 46.76 0.00 0.00 24.36 0.00 1.79 0.00 0.00 24.36 24.36 0.00 0.00 0.00 --- 1.59 -__0.00 __-_27.69 0.89 0.00 0.00 57.34 57.34 40.18 „ _ 0.0.0. 0.89 43.38 43.38 0.00 0.00 0.00 - --0All 0.89 42.20 0.00 0.00- 43.38 0.00 0.00- 0.89 0.00 0.00 58.95 58.95 0.00 0.00 0.00 - 1.49 0.00 _-0.00 0 0 0 0 0 0 -- 0 0 0 0 0 0 0 -- - 0 0 0` 0 0 0 _-,..0 70 0 0 0 20 0 0 0 -----228 Q_._ _ - - -0 _ 00 0 0 0 0 0 ... -- .0. 0 0 0 0 0 0 --- '0 0 0 0 0 0 -----0 50 0 0 0 0 0 0 0 -'--0 ----_. 228 -_- 0 _ _0 - --- 0 0 0 0 0 ----0 0 0 0 0 0 0 .,- - --0 0 0 0 0 0 0 ----0-- 90 0 0 0 487 0 0 0 _-- ---0 -----_ 362 ------0 -..- - -0 -- - -0 o 0 0 0 0 0 - -,----0 0 0 0 0 0 0 - - - -0 0 0 0 0 0 0 ----0-0 44 0 0 0 1179 0 0 0 _ _ 0 - - --339 ----- -0 -- -0 - 0 0-_0 0 0 0 0 0 ---_- --0. 0 0 0 0 0 0 --- 0 0 0 0 0 0 0 130 0 0 0 0 0 0 0 . _ _ - 0 ----- 104 ---- � - - 0 . - -0 0 0 0 0 0 0 0 0 0 0 0 - -- 0 0 0 0 0 0 -- -0 130 0 0 0 0 0 0 0 .. 0 _--104 - -- - - � -- --0 -_ - ---- 0 0 0 0 0 0 0 0 0 0 0 0 - --- - 0 0 0 0 0 0 0 ----0-- 233 0 0 0 0 0 0 0 _ _ _ _ 0 --- -- 165 --- -----0 ---- 0 0 0 0 0 0 0 0 0 0 0 0 0 - -0 0 0 0 0 0 0 - 1 116 0 0 0 0 0 0 0 -----0 ---_-155- ---- ---0 G _�-G C_ _---- F----0,00 F_-.-_..2291p1 6 c) AED excursion 257 -40 Envelope losstgain 938 1819 398 230 12 a) Infiltration b) Room ventilation 146 0 40 0 272 0 74 0 13 Internal gains: Occupants@ 230 Applianoes/other 0 0 0 0 0 0 Subtotal (lines 6 to 13) 1085 1859 669 305 14 15 Less extemalload Lesstransfer Redistribution Subtotal Duct loads 21% 16% 0 0 485 1569 337 0 0 221 2080 324 21% 16%1 0 0 -669 0 0 0 0 -305 0 0 Total room load Airrequired(dm) 1906 91 2404 126 0 0 100 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. -Fk- 2018-JU-1707:33:40 - - Right-Suite®Uriversal201818.0.16 RSU08101 Page 14 CK\DoarnertslWrigttsoftHVACWRBUCCI,MARIO.n{p CaIc=MJ8 Frort Door faces: SW -°b Fr wrightsoftRiaht-J@ Date: JUNE 14, 2018 OR& 2 By: QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@,AOL.COM 1 2 3 4 5 Room name Exposed wall Room height Room dimensions Room area BATH 2 5.0 It 10.0 It heaV000l 10.0 x 5.0 It 50.0 its WIC 3 5.0 It 10.0 It heat/000l 10.0 x 5.0 It 50.0 ft2 Ty Construction number U-value (BtuhA?-°F) Or HTM (Btuh/ft). Area (T) or perimeter (ft) Load (Btuh) Area (IF) or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 11 ���' 13B.5ooi�s'� 1OA-v r 1013-v 1A-lov -- 1A-cloy'' 1A-r1obd 1&Oprnd 136-5oons 1D-c2om 1 D-r2om 1 D-c2ov 1 D-c2ov 1 D-c2ov 1D-c2ov 13B 5aan5 . 1 OA-m 10A-m ' 10A-v 1D•t2om 1 D=c2cv 1D•t2ov_..__._ _�.- 1313-500As 1A-h1ov 1A-h1cv 1DQom 1 D-c2om 1 Dc2cv 1 D-c2ov 1 D-c2ov 16X19-0md 22Ahp1 .22A- I - _ _- 64 „ 0.0 0.820 0.600 0.900 0.900 1.080 1.270 0.064 0,870 0.870 0.570 0.570 0.570 0.570 0.064sw 1.670 1.670 0.820 0.870 0.570 , 0.5TO 0.064 0.900 0.900 0.870 0.870 0.570 0.570 0.570 OA08 _-__0.989 j 9W _ ne ne ne ,ne ` ne ne _ne se se se se se se se sw , sw . sN sw sw sw nw nw nw nw nw nw nw nw _ - - �_- 1:7_-9 ,: 6.00 0.00 2520 25.20 3024 _.:0,00 1.79 24.36 24.36 0.00 0.00 0.00 �0.00 ' 1.79 46.78 0:00 0.00 24.36 0.00 0.00 1.79 0.00 0.00 24.36 24.36 0.00 0.00 0.00 1.59 0,90 0.00 ._ __ 27.69 . __ .8. 0.89 ,. 0.00 • 0.00 57.34 57.34 40.18 _ 0.00.. 0.89 43.38 43.38 0.00 0.00 0.00 0.00 `0.89 •42.20 0.00' `•- 0.00 . 43.38 0.00 -_-�0.00 0.89 0.00 0.00 58.95 58.95 0.00 0.00 0.00 _. 1.49 0.00 __ Wd -.-. -0o . 0 ! 0 0 0 • 0 _0 50 10 0 0 0 0 0 ---6 0 - 0 " 0 " 0 0, .,_ 0 0 0 0 0 0 0 0 0 TM 50 __. 0 _ 9 _-_. _.. _0 0 0 0 0' 0 _..-._._.._0 40 5 0 0 0 0 0 _ 0 0 0 0 0 0 __.: 0 0 0 0 0 0 0 0 0 _ 50 _ 0 _:_._e _ U _X___..____ 0. 0 0 0 0 0" __ �._. O 72 244 0 0 0 0 __- 0 __ 0 0 - , 0 0 0 0' ___-_-__0 0 0 0 0 0 0 0 0 _ _ 79 _ 0. _ ----0 0 0 0 0 0 ___ _0 36 434 0 0 0 0 0 m -0-_ 0 0 6 0 0 _ _0 0 0 0 0 0 0 0 0 _ 74 y_ 0 0 0 0 0 0 0 __A 50 0 0 0 0 0 0 __0 0 ' 0 0 0 0 0 0 0 0 0 6 �0. __ Q 50 0 0 0 0 0 0 ________..0 0 0 0 0 0 _0 0 0 0 0 0 0 0 0 _---_ 0. 0 0 0 "0 0 _ Q 90 0 0 0 0 0 0 -0 0 0 0 0 0 _ -_0 0 0 0 0 0 0 0 0 79 _ ___ 0 0 0 0 0 0 44 0 0 0 0 0 0 0 0 0 0 0 0 ._- __ _0 0 0 0 0 0 0 0 0 74 G Y _ - ' __ .� 0 0 0 0 0 0 0 0 50 0 C _F -__ 50 0 0 �_. _ 0 6 c) AED exajrsion 126 -17 Envelope loss(gain 395 670 169 102 12 a) Infiltration b) Room ventilation 104 0 29 0 104 0 29 0 13 Internal gains Occupants@ 230 Applianceslother 0 0 0 0 0 0 Subtotal (lines 6to 13) 499 699 273 130 14 15 Less extemalload Lesstransfer Redistribution Subtotal Ductloads 21% 16% 0 0 0 499 107 0 0 0 699 109 21% 16% 0 0 0 273 59 0 0 0 130 20 Total room load Air required (cfm) 606 29 808 42 332 16 151 8 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. +1r wrightsoft 2018-Jed-1707:33AO 1 ® -� Right-SulteUrgVersal201818.0.16 RSU08101 Page 15 '��f'`...CK\Doamerds\WtightwftHVACWRBUCCI,MARIO.rup Calc=MJB Front Door faces: SW -1- wrightsoft° ht-J® Worksheet Job: RiMITT 2 Date: JUNE 14, 2018 By: QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax. 772-466-6796 Email: QUICKCALCS@,AOL.COM 1 2 3 4 5 Room name E>posed vvall Room height Room dimensions Room area BEDROOMS 26.0 it 10.0 It heat/cool 14.0 x 12.0 ft 168.0 ftz BATH 3 8.0 It 10.0 ft heat/000l 5.0 x 10.0 ft 50.0 fP Ty Construclion number U-value (Bfuh/R-°F) Or HTM (Btuh/fF) Area (ft=) or perimeter (ft) Load (Btuh) Area (W) or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 11 W - 13B-5ooAs - -- - 1GA-v IOB-v AA-c1ov IA-clov IA-r1obd 1A_.-rlomd-------- 136-5ooAs 1 D- tom 1D-c2om 1 D-c2ov 1 D-c2ov 1 D-c2ov _1DQov _-_-_-- 138-5oohs 1OA-m 10A-m 10A v 1 D-c2om 1 D-c2ov JD-c2ov _ 1313-5ooAs 1A-h1ov 1A-h1ov 1 D-c2om 1 D-c2om 1 D-c2ov 1 D-c2ov _1 D-c2ov _--_ - 12C Osw - --- 16X19-0md_ --__ _ -- 0.064 0:820 0.'600. 0.900 0.900 1.080 --1..270 0.064 0.870 0.870 0.570 0.570 0.570 -__-- 0.570 0.064 1.670 1.670 0.820 0.870 0.570 --0.570 0.064 0.900 0.900 0.870 0.870 0.570 0.570 - ___. 0.570 - _-0.091. _-.0408�1.591.49 ne ne ne ne ne ne _ne_ se se se se se se _se_ sw sw sw sw sw sw _sw nw nw nw nw nw nw nw nw --' - 1.79 0.00 0.00 25.20 , 25.20 3024 ____O.00----0'0.0. 1.79 24.36 24.36 0.00 0.00 0.00 ,�_0.00 1.79 46.76 0.00 0.00 24.36 - 0.00 --000 1.79 0.00 0.00 24.36 24.36 0.00 0.00 0_00 ---0.00 _ ,_0.00 - 0.00 27.69 - 0.89 0.00 0:00 57:34 57.34 40.18 0.89 43.38 43.38 0.00 0.00 0.00 __ 0.00 - 0.89 42.20 0.00 0.00 43.38 ' 0.00 --OAO 0.89 0.00 0.00 58.95 58.95 0.00 0.00 _ - 0.00 - --0 00 -_.. 0.00 -. _ 0.00_ - - _0 0 0 0 0 0 _�--0 120 20 0 0 0 0 ____ _ 0- - 140 40 0 0 10 0 __ _ _0 0 0 0 0 0 0 0 -. 0 -_-----0 __--168 0 9$. - --0 0 0 0 0 0 - - 0---- 100 10 0 0 0 0 -_---- 0 90 2 0 0 5 0 0 -- 0 0 0 0 0 179 487 0 0 0 0 -- ----0 161 1870 0 0 244 0 -_ -__0, 0 0 0 0 0 0 0 - - 0 0 0 0 0 0 89 868 0 0 0 0 ----.---0 80 1688 0 0 434 0 ------ 0 0 0 0 0 0 0 0 ----- 0 - ---0 250 _ 0 -- - 0 -- -- 0 0 0 0 0 0 0 0 0 0 0 - ---_ 0 50 0 0 0 10 0 -----0 30 0 0 0 0 0 0 0 --- - 9 50 0 -- --35 - - - 0 0 0 0 0 0 0 0 0 0 0 _ ___ 0 - 40 0 0 0 5 0 -_--0 30 0 0 0 0 0 0 -_ --- 0 -- - 50 -_ 0 ------ -- -- 0 0 0 0 0 0 0 0 0 0 0 0 _ 0 '-- 72 0 0 0 244 0 -----------0_---- 54 0 0 0 0 0 0 -------- 4 - - --Q --_ _ 79 _ _ 0 - - --0 0 0 0 0 0 0 0 0 0 0 0 _ _ _ 0 36 0 0 0 434 0 27 0 0 0 0 0 0 ----_ 0 -- -- -0_C _ 74 - 0 -_ ---. - _ -- 0 0 0 0 0 0 0 . __.. 0 -- - -0 168 _ Y_0 - _15 G --__ P - - F9 -0 - --- 0 266 _ 0 -- -42Q 6 c) AED excursion -84 180 Envelope loss/gain 3628 33241 603 750 12 a) Infiltration b) Room ventilation 543 0 149 0 167 0 46 0 13 Internal gains Oocupants@ 230 AppliancerVother 0 0 0 0 0 0 Subtotal (lines 6to 13) 4171 3473 771 796 14 15 Less ekemalload Lesstransfer Redistribution Subtotal Duct loads 21% 16% 0 0 0 4171 896 0 0 0 3473 541 21% 16 0 0 0 0 771 165 0 0 0 796 124 Total room load Air required (dm) 5067 2411 4014 211 936 45 920 48 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. wrlghtsoTt- - 2018-Jul-17 07:33AO ACCA Right-Sute®Universal 201818.0.16 RSU08101 Page 16 ...CK1Doamerts\WrightsoftHVAC1ARBUCCI,MARIO.n¢r Calc=MJ8 Front Door faces: SW -rF wrightsofta Right-J® Worksheet Job: UNIT 2 Date: DUNE 14, 2018 By: QUICK CALCS, INC. 317 ST. LUCIE LN., Fr.. PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466-6796 Email: QUICKCALCS@,40L.COM 1 Room name OFFICE 2 Exposed wall 21.0 ft 3 Room height 10.0 ft heat/000l 4 5 Room dimensions Room area 9.0 x 12.0 ff 108.0 flz Ty Construction U-value Or HTM Area (ftz) Load Area Load number (Btuh/fl�°F) (Btuhtfl or perimeter (ft) (Btuh) or perimeter Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13B-5oays 0.064 ne -._--_-_---_-___..__-._.----.--,-..___-_ 1:79 0.89 0 0 0 __-__---___-_.__..___-..---.----.-.-_-_--__. 0 10A-v 0.820 ne 0.00 0.00 0 0 0 0 1013-v 0.600 ne 0.00 0.00 0 0 0 0 1A-dov 0.900 ne 25.20 57.34 0 0 0 0 11 IA-clov 0.900 ne 25.20 57.34 0 0 0 0 1A-r1obd 1:080 ne 30.24 40.18 0 0 0 0 1A-0omd- - --- -1.270 ..ne- ----0.00 0- 0 - -- 136-5ochs 0.064 se 1.79 _. -_0.00..----- 0.89 ---0 0 --- - 0 - - 0 0 1 D- tom 0,870 se 24.36 43.38 0 0 0 0 1 D-c2om 0.870 se 24.36 43.38 0 0 0 0 1 D-c2ov 0.570 se 0.00 0.00 0 0 0 0 1 D-c2ov 0.570 se 0.00 0.00 0 0 0 0 1 D-c2ov 0.570 se 0.00 0.00 0 0 0 0 1D-c2ov 136-5ocns 0,570 0.064 se0.00..--_0.00._--_0-,0 - sw 1.79 0.89 90 50 -.__- 0.__-----__0 90 44 - 10A-m 1.670 sw 46.76 42.20 40 2 1870 1688 10A-m 1,670 sw 0.00 0.00 0 0 0 0 10A-v 0,820 sw 0.00 0.00 0 0 0 0 1 D-c2om 0.870 sw 24.36 43.38 0 0 0 0 1D-c2ov 0.570 sw 0.00 0.00 0 0 0 0 ------.1D-aa%v__---- - - 0.570 -s -- 0.00 0._00 136-5ooms 0.064 nw 1.79 -- 0.89 - ----0 120 -- - -Q 120 - ----0 215 - -0 167 - ---- --- - -- - -- 1A-hlov 0.900 nw 0.00 0.00 0 0 0 0 1A-h1ov 0.900 nw 0.00 0.00 0 0 0 0 1 D-r2om 0.870 nw 24.36 58.95 0 0 0 0 1 D-c2om 0.870 nw 24.36 58.95 0 0 0 0 1 D-c2ov 0.570 nw 0.00 0.00 0 0 0 0 1 D-c2ov 0.570 nw 0.00 0.00 0 0 0 0 -- 1 D-c2ov 0.570 nw 0.00 0.00 0 0 0 0 - - ---- -- - - - - - - - . 0.091 - _ - - - - 0.00 - �- -- -- 0.00- - - - - 0. - -- - - -- 0 -- - - ---- - ----- - - - -.. C - 18X1.9-0md-- - _.--- 0.408 -..- - - 108 -- -0 108 -- - 171 - 160 19C-19 - �P----------0.049-c-----0.00 -- -_--1.59.--- -_1-.49 ----0.00 -- ----0 _. -- -.._ ._.- --- F _ __- 22A_tol_ _ - - -- - -__-- 0.989 0,00 0 -------_0.- -----8 0 ------0- 0 - --- F___-.._ -_--- .�A-WL__ _ _-0.989 -_- _ :_. _._ _ _ _..27.69 _ _-0.00 _ 0.0Q ._ _-72, _ _ _ _ _0 _14 388 .- ---0 - 6 c) AED excursion 220 Envelope losslgain 2734 2220 12 a) Infiltration 439 120 b) Room ventilation 0 0 13 Internal gains Occupants@ 230 0 0 Applianceslother 0 Subtotal (lines 6to 13) 3173 2340 Less external load 0 0 Lesstranster 0 0 Redistribution 0 0 14 Subtotal 3173 2340 15 Duct loads 21% 16% 681 365 Total room load i i 3854 2705 Air required (dm) 183 142 Calculations approved bvACCAto meet all requirements of Manual J 8th Ed. wrightsoft ^�^•^- �^^•-��^-A Right-Su2018-Jed-17 07:33:40 ��te®Urdversa1201818.0.16 RSU08101 Page 17 CK\Doamn ents\WrightsoftHVAC\ARBUCCI,MARIO.p Calc=MJ8 Front Door faces: SW DuctSystem SummaryJob: +�++ wrightsoft® St Date: JUNE 14, 2018 UNIT 1 By. QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phore: 772-466-6799 Fax: 772-466-6796 Email: QUICKCALCS@40L.COM Project• • For: MARIOARBUCCI LOT 46 4832 WATERSONG WAY ST. LUCIE COUNTY, FL External static pressure Pressurelosses Available static pressure Supply / return available pressure Lowest fiction rate Actual airflow Total effective length (TEL) Heating 0.50 in H2O 0 in H2O 0.50 in H2O 0.250 / 0.250 in H2O 0.153 in/100ft 1600 cfm 326 ft Cooling 0.50 in H2O 0 in H2O 0.50 in H2O 0.250 / 0.250 in H2O 0.153 i n/100ft 1600 dim Name Design (Btuh) Htg (Cfm) Clg (Cfrn) Design FR Diam (in) H x W (in) Duct Matl Actual Ln (ft) Ftg.Egv Ln (ft) Trunk 13ATH4 C 635 32 33 0.321 4.0 Ox0 MFx 11.0 145.0 SO BEDROOM4 h 4164 191 129 0.272 8.0 Ox0 MFx 19.0 165.0 st8 CABANA h 899 41 38 0.179 5.0 Ox0 MFx 64.0 215.0 st11 FLEXROOM h 4060 186 120 0.168 8.0 Ox0 MFx 63.0 235.0 st11 FOYER h 2302 105 87 0.276 6.0 Ox0 MFx 26.0 155.0 st9 FOYER -A h 2302 105 87 0.329 6.0 Ox0 MFx 17.0 135.0 st9 GREATROOM C 3154 143 165 0.205 7.0 Ox0 MFx 49.3 195.0 st7 GREATROOM-A C 3154 143 165 0.207 7.0 Ox0 MFx 46.8 195.0 st7 GREATROOM-B c 3154 143 165 0.234 7.0 Ox0 MFx 39.0 175.0 st7 GREATROOWC C 3154 143 165 0.235 7.0 Ox0 MFx 38.0 175.0 st7 KITCHEN C 1728 29 90 0.272 6.0 Ox 0 MFx 29.0 155.0 st7 KITCHEN•A c 1728 29 90 0.282 6.0 Ox 0 MFx 22.0 155.0 st7 LAUND. h 1845 84 47 0.153 4.0 Ox0 MFx 71.0 255.0 st11 LAUNDRY c 1036 36 54 0.251 5.0 Ox0 MFx 24.0 175.0 st8 POWDER h 1639 75 47 0.415 5.0 Ox0 MFx 5.6 115.0 st2 STAIRWAY c 2147 86 112 0.410 7.0 Ox0 MFx 7.0 115.0 st1 STORAGE h 585 27 6 0.198 4.0 Ox0 MFx 57.0 195.0 st11 wrightsoft® 2018-JU-1 7 07:33:43 Right-Srete4DUrdversal20l8l8.O.l6RSUD8101 Page ACCK...CK1Doamerts\WrightsoftHVACWRBUCCI,MARIO.np Calc=MJB Frort Door faces: SW Supply Trunk Detail Table Name Trunk Type Htg (cfm) Clg (cfm) Design FR Veloc (fpm) Diam (in) H x W (in) Duct Material Trunk st11 PeakAVF 338 211 0.153 620 10.0 0 x 0 VInIFIX st10 st9 PeakAVF 549 386 0.153 699 12.0 0 x 0 VInIFIx st3 st10 PeakAVF 338 211 0.153 620 10.0 0 x 0 VinlFlx SO st3 PeakAVF 549 386 0.153 699 12.0 0 x 0 VinlFlx st2 PeakAVF 334 263 0.251 757 9.0 0 x 0 VInIFIX st8 PeakAVF 259 216 0.251 743 8.0 0 x 0 VinlFlx st2 st1 PeakAVF 717 951 0.205 890 14.0 0 x 0 VnIFIX st7 PeakAVF 631 839 0.205 785 14.0 0 x 0 VinlFlx st6 st6 PeakAVF 631 839 0.205 785 14.0 0 x 0 VinlFlx st1 Return Branch Detail Table Name Grille Size (in) Htg (cfm) Clg (cfm) TEL R Design FR Meloc (fpm) Diam (in) H x W (in) Stud/Joist Opening (in) Duct Mat Trunk rb3 Ox 0 1600 1600 0 0 0 0 Ox 0 MFx wrightsoft" ^►: a,� w, .,�.� 9ght-Stjfte@UNversa1201818.0.16RSU08101 ACCA...CK1Docunerfs\WriglftsoftWAC\ARBUCCI,MARIO.rup Calc=MA Frord Door %ces: SW 2018-JU-17 07:33A3 Page 2 wrightsoft® Duct System Summary UNIT 2 QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466-6796 Email: QUICKCALCS@-AOL.COM For. MARIO ARBUCCI LOT 46 4832 WATERSONG WAY ST. LUCIE COUNTY FL External static pressure Pressure losses Available static pressure Supply / return available pressure Lowest fiction rate Actual airflow Total effective length (TEL) Heating 0.50 in H2O 0 in H2O 0.50 in H2O 0.250 / 0.250 in H2O 0.161 in/100ft 1200 dim 310 ft Supply Branch Detail Table Job: Date: JUNE 14, 2018 By: Cooling 0.50 in H2O 0 in H2O 0.50 in H2O 0.250 / 0.250 in H2O 0.161 in/100ft 1200 cfm Name Design (Btuh) Htg (cfm) Clg (cfm) Design FIR Diam (in) H x W (in) Duct Mat Actual Ln (ft) Ftg.Egv Ln (ft) Trunk BATH c 808 29 42 0.370 4.0 Ox0 VIFx 15.1 120.0 st4 BATH 3 c 920 45 48 0.345 4.0 Ox 0 VIFx 10.0 135.0 st5 BEDROOM 2 c 1805 73 95 0.321 7.0 Ox 0 VIFx 16.0 140.0 st4 BEDROOM 3 h 5067 241 211 0.298 8.0 Ox 0 VIFx 13.0 155.0 st5 HALLWAY c 2404 91 126 0.256 6.0 Ox 0 ShMt 15.2 180.0 st4 M WIC h 950 45 21 0.208 4.0 Ox 0 VIFx 40.0 200.0 st4 MASTER BATH c 3266 160 171 0.161 6.0 Ox0 VIFx 50.0 260.0 st4 MASTERSUITE c 2611 136 137 0.164 7.0 Ox0 VIFx 44.6 260.0 st4 MASTERSUITE-A c 2611 136 137 0.198 7.0 Ox0 VIFx 32.0 220.0 st4 OFFICE h 3854 183 142 0.394 6.0 Ox0 VIFx 12.0 115.0 st5 TOILET c 945 24 50 0.175 4.0 Ox0 VIFx 46.0 240.0 st4 WIC h 92 4 4 0.246 4.0 Ox 0 VIFx 23.0 180.0 st4 WIC2 h 364 17 8 0.266 4.0 Ox0 VIFx 27.8 160.0 st4 WIC h 332 16 8 0.336 4.0 Ox0 VIFx 13.6 135.0 sty Trunk Htg Clg Design Meloc Diam H x W Duct Name Type (cfm) (dim) FIR (fpm) (in) (in) Material Trunk st4 PeakAVF 715 791 0.161 740 14.0 0 x 0 VinIFIX st5 PeakAVF 485 409 0.298 889 10.0 0 x 0 VInIFIx * wrightsoft® �, �,- , Right-SmoteOUrriversal201818.0.16RSU08101 ACC% ...CK1Doamerds\Wrigtt oft HVACWRBUCCI,MARIO.np CaIc=MJ8 Frort Door faces: SW 2018-JQ-17 07:33A3 Page 3 Name Grille Size (in) Htg (cfm) Clg (cfm) TEL (ft) Design FR Meloc (fpm) Diam (in) H x W (in) Stud/Joist Opening (in) Duct Mat Trunk rb2 Ox0 1200 1200 0 0 0 0 Ox 0 MFx - - =ightsoft® Right Sute®Urrversa1201818.0.16RSU08101 CK\Doamertss\WrigtdsoftHVAC1ARBUCCI,MARIO.np Calc=MJ8 FrordDoor faces: SW 2018-JU-17 07:33:43 Page 4