HomeMy WebLinkAboutcompaction testIn -Place Density Report
8t Associates, Inc. Permit # 2009-0143
Report Date: 10/21/2020
Port St. Lucie Branch
Test Method: ASTM D6938
Florida Registration No. 5950
460 NW Concourse Place, Unit 1
Port Lucie, FL 34986
Phone: e:772-878-8.0072
Client: Project:
Renar Development Corp. 113-15-66-5434B
3725 S. East Ocean Boulevard, Suite 101 Morningside Residential Lots
Stuart, FL 34996 Fort Pierce
Fort Pierce, FL
Test Results
Test #
Retest
Of
Test
Date
Proctor ID
Method
Soil
Classification
Optimum
Moisture
(%
Maximum
Dry Density
(pc
In Place
Moisture
%
In Place
Dry
Density
pcf)
In Place
Wet
Density
pcf)
Probe
Depth
(in)
Percent
Compaction
Min Comp.
%)
Remark
374
10/16/20
20-273
(Modified)
A
10.5
113.5
10.3
107.7
118.8
12
95
95
Pass
375
10/16/20
20-273
(Modified)
A
10.5
113.5
8.9
108.2
117.8
12
95
95
Pass
376
10/16/20
20-273
(Modified)
A
--
10.5
113.5
7.3
113.3
121.6
12
100
95
Pass
377
10/16/20
20-273
(Modified)
A
10.5
113.5
8.2
110.8
119.9
12
98
95
Pass
378
10/16/20
20-273
(Modified)
A
10.5
113.5
13.8
107.4
122.2
.12
95
95
Pass
379
10/16/20
20-273
(Modified)
A
--
10.5
113.5
15.5
109.4
126.3
12
96
95
Pass
380
10/16/20
20-273
(Modified)
A
10.5
113.5
14.1
110.1
125.6
12
97
95
Pass
381
10/16/20
20-273
(Modified)
A
-
10.5
113.5
12.6
108.1
121.7
12 1
95
1 95
Pass
Test
Information
Test #
Test Location
Elevation
Reference
Gauge
Make / Model / SN / Calibrated
Field Technician
374
Building Pad Fill: House Pad at 9792 Palm Breezes Dr. Lot 100. S Corner
-1.0
Top of Pad
Troxler / T-3430 / 21330 /
Tech, Port St. Lucie
375
Building Pad Fill: House Pad at 9792 Palm Breezes Dr. Lot 100. E Corner
-1.0
Top of Pad
Troxler / T-3430 / 21330 /
Tech, Port St. Lucie
376
Building Pad Fill: House Pad at 9792 Palm Breezes Dr. Lot 100. N Corner
-1.0
Top of Pad
Troxler / T-3430 / 21330 /
Tech, Port St. Lucie
377
Building Pad Fill: House Pad at 9792 Palm Breezes Dr. Lot 100. W Corner
-1.0
Top of Pad
Troxler / T-3430 / 21330 /
Tech, Port St. Lucie
378
Footings: House Pad at 9792 Palm Breezes Dr. Lot 100. SE Footing
-2.0
Top of Pad
Troxler / T-3430 / 21330 /
Tech, Port St. Lucie
379
Footings: House Pad at 9792 Palm Breezes Dr. Lot 100. NE Footing
-2.0
Top of Pad
Troxler / T-3430 / 21330 /
Tech, Port St. Lucie
380
Footings: House Pad at 9792 Palm Breezes Dr. Lot 100. NW Footing
-2.0
Top of Pad
Troxler / T-3430 / 21330 /
Tech, Port St. Lucie
381
Footings: House Pad at 9792 Palm Breezes Dr. Lot 100. SW Footing
-2.0
Top of Pad
Troxler / T-3430 / 21330 /
Tech, Port St. Lucie
Remarks
comments
Pass: Density Pass
Tests are "Direct Transmission" (Method A) unless probe depth is noted as
"Backscatter". Gauge calibration data on file with the testing agency.
AS A MUTUAL PROTECTION TO OUR CLIENT, THE PUBLIC AND OURSELVES, ALL REPORTS ARE SUBMITTED AS THE CONFIDENTIAL PROPERTY OF Page 1 of 2
THE CLIENT, AND AUTHORIZATION FOR PUBLICATION OF STATEMENTS, CONCLUSIONS OR EXTRACTS FROM OUR REPORTS IS RESERVED PENDIN(
OUR WRITTEN APPROVAL.
m7 a r man In -Place Density Report
00% & Associates, Inc. Permit # 2009-0143
Report Date: 10/21/2020
Port St. Lucie Branch Test Method: ASTM D6938
Florida Registration No. 5950
460 NW Concourse Place, Unit 1
Port St. Lucie, FL 34986
Phone:772-878-0072
Client:
Renar Development Corp.
3725 S. East Ocean Boulevard, Suite 101
Stuart, FL 34996
Project:
113-15-66-5434B
Morningside Residential Lots
Fort Pierce
Fort Pierce, FL
41
* ; No. 63911
r '
' ra or .=
�,rrriON L ON 0
This item has been digitally signed and sealed by Branch
Manager Dan J. Zrallack, P.E. on Oct 21, 2020 using a
Digital Signature.
Printed copies of this document are not considered signed
and sealed and the SHA authentication code must be
verified on any electronic copies.
AS A MUTUAL PROTECTION TO OUR CLIENT, THE PUBLIC AND OURSELVES, ALL REPORTS ARE SUBMITTED AS THE CONFIDENTIAL PROPERTY OF Page 2 of 2
THE CLIENT, AND AUTHORIZATION FOR PUBLICATION OF STATEMENTS, CONCLUSIONS OR EXTRACTS FROM OUR REPORTS IS RESERVED PENDING
OUR WRITTEN APPROVAL.