HomeMy WebLinkAboutcompaction testmg a In -Place Density Report Client:
Project:
& Associates, Inc.
Permit # 2009-0475
Renar Development Corp.
113-15-66-5434B
Report Date: 10/21/2020
3725 S. East Ocean Boulevard, Suite 101
Morningside Residential Lots
Port St. Lucie Branch
Test Method: ASTM D6938
Stuart, FL 34996
Fort Pierce
Florida Registration No. 5950
460 NW Concourse Place, Unit 1
Port St. Lucie, FL 34986
Fort Pierce, FL
Phone: 772-878-8-0072
Test Results
Test #
Retest
Of
Test
Date
Proctor lD
Method
Soil
Classification
Optimum
. Moisture
N
Maximum
Dry Density
(pcf)
In Place
Moisture
%
In Place
Dry
Density
(pcf)
In Place
Wet
Density
(pcf)
Probe
Depth
(in)
Percent
Compaction
Min Comp.
N
Remark
358
10/16/20
20-277
(Modified)
A
--
10.5
109.5
5.6
107.9
113.9
12
99
95
Pass
359
10/16/20
20-277
(Modified)
A
10.5
109.5
7.1
105.4
112.9
12
96
95
Pass
360
10/16/20
20-277
(Modified)
A
10.5
109.5
8.3
106.3
115.1
12
97
95
Pass
361
10/16/20
20-277
(Modified)
A
--
10.5
109.5
7.8
107.2
115.6
12
98
95
Pass
362
10/16/20
20-270
(Modified)
A
10.5
106.0
9.2
101.3
110.6
12
96
95
Pass
363
10/16/20
20-270
(Modified)
A
--
10.5
106.0
11.7
100.6
112.4
12
95
95
Pass
364
10/16/20
20-270
(Modified)
A
--
10.5
106.0
8.1
102.3
110.6
12
97.
95
Pass
365
10/16/20
20-270
(Modified)
A
-
10.5
106.0
10.3
101.1
111.5
12
95
95
Pass
Test
Information
Test #
Test Location
Elevation
Reference
Gauge
Make / Model / SN / Calibrated
Field Technician
358
Building Pad Fill: House Pad at 9508 Silver Sands Ln. Lot 3. SE Corner
-1.0
Top of Pad
Troxler / T-3430 / 21330 /
Tech, Port St. Lucie
359
Building Pad Fill: House Pad at 9508 Silver Sands Ln. Lot 3. NE Corner
-1.0
Top of Pad
Troxler / T-3430 / 21330 /
Tech, Port St. Lucie
360
Building Pad Fill: House Pad at 9508 Silver Sands Ln. Lot 3. NW Corner
-1.0
Top of Pad
Troxler / T-3430 / 21330 /
Tech, Port St. Lucie
361
Building Pad Fill: House Pad at 9508 Silver Sands Ln. Lot 3. SW Corner
-1.0
Top of Pad
Troxler / T-3430 / 21330 /
Tech, Port St. Lucie
362
Footings: House Pad at 9508 Silver Sands Ln. Lot 3. E Footing
-2.0
Top of Pad
Troxler / T-3430 / 21330 /
Tech, Port St. Lucie
363
Footings: House Pad at 9508 Silver Sands Ln. Lot 3. N Footing
-2.0
Top of Pad
Troxler / T-3430 / 21330 /
Tech, Port St. Lucie
364
Footings: House Pad at 9508 Silver Sands Ln. Lot 3. W Footing
-2.0
Top of Pad
Troxler / T-3430 / 21330 /
Tech, Port St. Lucie
365
Footings: House Pad at 9508 Silver Sands Ln. Lot 3. S Footing
-2.0
Top of Pad
Troxler / T-3430 / 21330 /
Tech, Port St. Lucie
Remarks
I Comments
Pass: Density Pass
Tests are "Direct Transmission" (Method A) unless probe depth is noted as
"Backscatter". Gauge calibration data on file with the testing agency.
AS A MUTUAL PROTECTION TO OUR CLIENT, THE PUBLIC AND OURSELVES, ALL REPORTS ARE SUBMITTED AS THE CONFIDENTIAL PROPERTY OF Page 1 of 2
THE CLIENT, AND AUTHORIZATION FOR PUBLICATION OF STATEMENTS, CONCLUSIONS OR EXTRACTS FROM OUR REPORTS IS RESERVED PENDIN(
OUR WRITTEN APPROVAL.
' ,� a r In -Place Density Report client:
& Associates, Inc.
Port St. Lucie Branch
Florida Registration No. 5950
460 NW Concourse Place, Unit 1
Port St. Lucie, FL 34986
Phone:772.878-0072
Permit # 2009-0475 Renal, Development Corp.
Report Date: 10/21/2020 3725 S. East Ocean Boulevard, Suite 101
Test Method: ASTM D6938 Stuart, FL 34996
Project:
113-15-66-5434B
Morningside Residential Lots
Fort Pierce
Fort Pierce, FL
J.
No.6391, a * � r
1 �
5rA OF
:mow;'
,C �
ta,�' .
This item has been digitally signed and sealed by Branch
Manager Dan J. Zrallack, P.E. on Oct 21, 2020 using a
Digital Signature.
Printed copies of this document are not considered signed
and sealed and the SHA authentication code must be
verified on any electronic copies.
AS A MUTUAL PROTECTION TO OUR CLIENT, THE PUBLIC AND OURSELVES, ALL REPORTS ARE SUBMITTED AS THE CONFIDENTIAL PROPERTY OF Page 2 of 2
THE CLIENT, AND AUTHORIZATION FOR PUBLICATION OF STATEMENTS, CONCLUSIONS OR EXTRACTS FROM OUR REPORTS IS RESERVED PENDING
OUR WRITTEN APPROVAL.