Loading...
HomeMy WebLinkAboutcompaction testmg a In -Place Density Report Client: Project: & Associates, Inc. Permit # 2009-0475 Renar Development Corp. 113-15-66-5434B Report Date: 10/21/2020 3725 S. East Ocean Boulevard, Suite 101 Morningside Residential Lots Port St. Lucie Branch Test Method: ASTM D6938 Stuart, FL 34996 Fort Pierce Florida Registration No. 5950 460 NW Concourse Place, Unit 1 Port St. Lucie, FL 34986 Fort Pierce, FL Phone: 772-878-8-0072 Test Results Test # Retest Of Test Date Proctor lD Method Soil Classification Optimum . Moisture N Maximum Dry Density (pcf) In Place Moisture % In Place Dry Density (pcf) In Place Wet Density (pcf) Probe Depth (in) Percent Compaction Min Comp. N Remark 358 10/16/20 20-277 (Modified) A -- 10.5 109.5 5.6 107.9 113.9 12 99 95 Pass 359 10/16/20 20-277 (Modified) A 10.5 109.5 7.1 105.4 112.9 12 96 95 Pass 360 10/16/20 20-277 (Modified) A 10.5 109.5 8.3 106.3 115.1 12 97 95 Pass 361 10/16/20 20-277 (Modified) A -- 10.5 109.5 7.8 107.2 115.6 12 98 95 Pass 362 10/16/20 20-270 (Modified) A 10.5 106.0 9.2 101.3 110.6 12 96 95 Pass 363 10/16/20 20-270 (Modified) A -- 10.5 106.0 11.7 100.6 112.4 12 95 95 Pass 364 10/16/20 20-270 (Modified) A -- 10.5 106.0 8.1 102.3 110.6 12 97. 95 Pass 365 10/16/20 20-270 (Modified) A - 10.5 106.0 10.3 101.1 111.5 12 95 95 Pass Test Information Test # Test Location Elevation Reference Gauge Make / Model / SN / Calibrated Field Technician 358 Building Pad Fill: House Pad at 9508 Silver Sands Ln. Lot 3. SE Corner -1.0 Top of Pad Troxler / T-3430 / 21330 / Tech, Port St. Lucie 359 Building Pad Fill: House Pad at 9508 Silver Sands Ln. Lot 3. NE Corner -1.0 Top of Pad Troxler / T-3430 / 21330 / Tech, Port St. Lucie 360 Building Pad Fill: House Pad at 9508 Silver Sands Ln. Lot 3. NW Corner -1.0 Top of Pad Troxler / T-3430 / 21330 / Tech, Port St. Lucie 361 Building Pad Fill: House Pad at 9508 Silver Sands Ln. Lot 3. SW Corner -1.0 Top of Pad Troxler / T-3430 / 21330 / Tech, Port St. Lucie 362 Footings: House Pad at 9508 Silver Sands Ln. Lot 3. E Footing -2.0 Top of Pad Troxler / T-3430 / 21330 / Tech, Port St. Lucie 363 Footings: House Pad at 9508 Silver Sands Ln. Lot 3. N Footing -2.0 Top of Pad Troxler / T-3430 / 21330 / Tech, Port St. Lucie 364 Footings: House Pad at 9508 Silver Sands Ln. Lot 3. W Footing -2.0 Top of Pad Troxler / T-3430 / 21330 / Tech, Port St. Lucie 365 Footings: House Pad at 9508 Silver Sands Ln. Lot 3. S Footing -2.0 Top of Pad Troxler / T-3430 / 21330 / Tech, Port St. Lucie Remarks I Comments Pass: Density Pass Tests are "Direct Transmission" (Method A) unless probe depth is noted as "Backscatter". Gauge calibration data on file with the testing agency. AS A MUTUAL PROTECTION TO OUR CLIENT, THE PUBLIC AND OURSELVES, ALL REPORTS ARE SUBMITTED AS THE CONFIDENTIAL PROPERTY OF Page 1 of 2 THE CLIENT, AND AUTHORIZATION FOR PUBLICATION OF STATEMENTS, CONCLUSIONS OR EXTRACTS FROM OUR REPORTS IS RESERVED PENDIN( OUR WRITTEN APPROVAL. ' ,� a r In -Place Density Report client: & Associates, Inc. Port St. Lucie Branch Florida Registration No. 5950 460 NW Concourse Place, Unit 1 Port St. Lucie, FL 34986 Phone:772.878-0072 Permit # 2009-0475 Renal, Development Corp. Report Date: 10/21/2020 3725 S. East Ocean Boulevard, Suite 101 Test Method: ASTM D6938 Stuart, FL 34996 Project: 113-15-66-5434B Morningside Residential Lots Fort Pierce Fort Pierce, FL J. No.6391, a * � r 1 � 5rA OF :mow;' ,C � ta,�' . This item has been digitally signed and sealed by Branch Manager Dan J. Zrallack, P.E. on Oct 21, 2020 using a Digital Signature. Printed copies of this document are not considered signed and sealed and the SHA authentication code must be verified on any electronic copies. AS A MUTUAL PROTECTION TO OUR CLIENT, THE PUBLIC AND OURSELVES, ALL REPORTS ARE SUBMITTED AS THE CONFIDENTIAL PROPERTY OF Page 2 of 2 THE CLIENT, AND AUTHORIZATION FOR PUBLICATION OF STATEMENTS, CONCLUSIONS OR EXTRACTS FROM OUR REPORTS IS RESERVED PENDING OUR WRITTEN APPROVAL.