Loading...
HomeMy WebLinkAboutEngineering CSM CSM ENGINEERING, LLD 2OB 5W OCEAN BOULEVARD STUART, FLORIDA 34994 E N G I N E E R I N G ❑: 772-220-4601 CIVIL • STRUCTURAL • MARINE W: WWW.CSM-E.NET November 5,2020 � 10 Saint Lucie County Planning&Development Services Building&Code Regulation Division REVIEWED FOR 2300 Virginia Avenue Fort Pierce,Florida34982 IC;ODE; COMPLIANCE o: 772-462-1594 ST. LUCN.E: COUNTY Re: Hutchinson Island Club—Commercial Renovation of New Window Install BOCC.� 10410 S. Ocean Dr. Unit 806 Permit#: 2010-0666 Zv Dear Plan Reviewer, 1� The following are responses to the Conditions of Approval Dated 10-27-2020. Please, find the attached Wind Pressure engineering for the Unit described above (two attached pages). I have also reviewed and approved the NOA#20-0406.04 attached 24 pages. Main pages of concern(6,7,and 15). Thank you and your staff for the continued support. Sincerely, 0 �,.•''�\OENSF '•, FILE COPY No.76910 S SE OF Charles A. Darden Jr.,PE �� J Florida Engineering License No. 76910 csm ENGINEERING CIVIL - STRUCTURAL - MARINE PROJECT: HUTCHINSON ISLAND CLUB - UNIT 806 COMMERCIAL WINDOW INSTALL WIND PRESSURE STRUCTURAL DESIGN CRITERIA: THE DESIGN COMPLIES WITH THE REQUIREMENTS OF THE FLORIDA BUILDING CODE, BUILDING & EXISTING; 6TH EDITION; 2017, ASCE 7-10, & ASD MEAN ROOF HEIGHT 130' WIND VELOCITY 165 MPH; ULTIMATE WIND SPEED WIND VELOCITY 128 MPH; NOMINAL WIND SPEED EXPOSURE "D"; ENCLOSED DESIGN Qz 88 PSF Kd 0.85 Kz 1.48 REDUCTION FACTOR 0.6 ROOF SLOPE FLAT INTERNAL PRESSURE COEFFICIENT +/-0.18 PER TABLE 26.11-1 RISK CATEGORY II OCCUPANCY RESIDENTIAL R-2 CONSTRUCTION TYPE II A GENERAL COMPONENTS AND CLADDING NOTES: 1. WINDOW TO BE INSTALLED PER PRODUCT APPROVAL ZONE 4 AND MEET +/- 60 PSF PRESSURE DESIGN. \0I jlliilii,�/ �� �g A DARE�'�'�. No. 76910 3TAME OF : �i�� •'•.FCORII�P.•''�\�� tS � ZONAL;/ 0 •\• CHARLES A. DARDEN JR. DATE FLORIDA REp EDP iFE5901 NpNEER '6p10 CA �29057 CSM ENGINEERING 11`5-ada'o 208 S.W. OCEAN BLVD. STUART FL 34994 772—L20-4601 csm ENGINEERING R,�, 1/2• GYPSUM WOOD BOARD PT. WOOD FURRING (AS REO'D) PT. WOOD B OCKING PER PUNS AS REO'D) INTERIOR III WINDOW/DOOR FRAME PER PLANS • -PROPOSED WINDOW OOR (SEE PLAN FOR SIZE) TRIM EXTERIOR FLASHING/SEALANT SHALL EXTEND TO THE SURFACE OF THE EXTERIOR WALL FINISH AND SELF-ADHERED FLASHING SHALL COMPLY WITH AAMA 711. STUCCO FINISH 8' C.M.U. PER PLANS CONC. FILLED CELL TYPICALL WINDOW JAMB FLASHING DETAIL SCALE: N.T.S. WINDOW SCHEDULE DESIGNATION APPROX OPENING TYPE I QUANTITY REMARKS SIZE (WxH) 1O 7246 1 HORIZ. ROLLER 1 1 1 DOUBLE PANE. IMPACT WINDOW SCHEDULE: MANUFACTURER PRODUCT EVALUATION EXPIRATION WINDOW DESIGN CODE DESIGN APPROVAL NO. AGENCY DATE PRESSURE PRESSURE PGT NOA 20-D406.04 MIAMI DADE 08-23-2023 +65 PSF -65 PSF +60 PSF -60 PSF F V 'ENSF •. No. 715910 Q :�Q: 0 STATE OFR. ((/L '•.gOR%DPP..•'OR �i CINA�% "�� CHARLES A. DARDEN JR. DATE FIORIDA 7 ROFE599 AL EN 910 CA i29087 f CSM ENGINEERIN it -a0ao 208 S.W. OCEAN BL D. STUART FL 34994 772-120-4601