Loading...
HomeMy WebLinkAboutCertification for Design Load CompliancePlanning & Development Services Department Building & Code Regulations Division REVIEWED FOR 2300 Virginia Avenue, Fort Pierce, FL 34982 — (76� Ve 5'-;0MPLIANCE Certification for Design Load CorrrpliancST. � UCI E��ssi�� COUNTY Project Name: J And W Express Service Inc 931® Project Address: 405 N Ffa Rd Fort Pierce, FI 34945 Permit #: 1911-0473 Occupancy Type: NA Construction Type: IV INSTRUCTIONS FOR USE: * This certification must be completed, signed, and sealed by the design professional of record. * Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following: o New Residences (single or multi -family) o Residential Addition o Any accessory structure requiring a building permit �� o Any non-residential structure. PLE * Note: Form not required for interior renovations provided that no exterior structural elements are affected and certain minor building permits at the discretion of the local building official. Contact the # above for questions. DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply) 1. DESIGN CODE: Florida FBC Code Fifth Edition with 20 17 Supplements using ASCE 7-10 2. Structure Designed as (check one): _Enclosed _Partially Enclosed X Open 3. Risk Category: _I _II X III IV Exposure Category: X B _C _D 4. Design Wind Velocity 160 mph ASD LRFD End Zone Width: 40 ft 5. Mean Roof Height 17 ft Roof Pitch: 4 :12 Parapet: 0 ft 6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings): Zone 1: Zone 2: X Zone 3: Zone 4: Zone 5: Garage: 7. Design Loads: Floor: 40 PSF Roof/Dead: 40 PSF Roof/Live: 40 Balcony: PSF Dock: PSF Deck: PSF Stairs: PSF Fence: PSF Railings: PSF 8. Were Shear Walls Considered For Structure? _Yes x Not Applicable Explain Why Not: OPEN CONSTRUCTION WALLS 9. Is A Continuous Load Path Provided? X Yes _Not Applicable Explain Why Not: 10. Design Soil Bearing Pressure: 2000 @95% PSF Soil Test Reports Submitted? NO Yes DESIGN PROFESSIONAL CERTIFICATION STATEMENT: I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie County. I also certify that structural elements depicted on these plans provide adequate resistance to the design • forces specified: G��ii�,���/ Wayne Gandy .;9�/Q Print Name Cert # & Co. Cert Auth. • `� -3111. Signature, @t* ind dal * * _=�J��U L'• L01oli;,�L S E F company Name & Address �j Revised 07/25r iQ •`' /���i��SS�ONAi