Loading...
HomeMy WebLinkAboutProduct Approval; Metal Roofing11/19/2019 Florida Building Code Online Business & Professional Regulation r��ra BCIS Home I. Log In I User Registration I Hot Topics Submit Surcharge Stats & Facts Publications Contact Us BCIS Site Map Links Search Florida r iProduct Approval �r � USER: Public User L�hckPaW�vi m Product Approval Menu > Product or Application Search > Application List > Application Detail W OFFICE -OF THE FL # FL17796-Rl SECRETARY Application Type Revision Code Version 2017 Application Status Approved Comments Archived O Product Manufacturer Atlantic Metal II of Vero Beach Address/Phone/Email 4020 43rd Avenue Vero Beach, FL 32960 (772) 257-5730 FLvalidation@yahoo.com Authorized Signature William Lasky FLvalidation@yahoo.com Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Metal Roofing Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer 0 Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the LOCKE BOWDEN Evaluation Report Florida License PE-49704 Quality Assurance Entity Keystone Certifications, Inc. Quality Assurance Contract Expiration Date 06/11/2025 Validated By Zachary R. Priest, P.E. G Validation Checklist - Hardcopy Received Certificate of Independence FL17796 R1 COI FL 17796 1.0 Nail Strip 24GA over 15 32 Plywood - 2017 Code RR.12df Referenced Standard and Year (of Standard) Standard Year TAS 100 1995 TAS 125 2003 TAS110 2000 UL1897 2012 UL 580 2006 Equivalence of Product Standards Certified By Sections from the Code https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgs%2bbt23mL8HofjjKv7zYVGsdytxRV640WjfC3zOhF3BRA%3d%3d 1/3 11/19/2019 Florida Building Code Online Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved Method 1 Option D 01/24/2018 02/14/2018 02/20/2018 04/10/2018 FL # Model, Number or Name Description 17796.1 1 1/2" Nail Strip 1 1/2" Nail Strip 15 1/2" Wide over 1/2" Plywood - HVHZ. Complianr with FBC 2017 6th ed. Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-116.OPSF Other: 78.5 psf @ 11" o.c. -116.0 psf @ 6 1/2" o.c. Install per manufacturers details. For use in HVHZ Zones. 17796.2 11 1/2" Snap Lock Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-101.OPSF other: -86.0 psf @ 24" o.c. -108.5 psf @ 12" o.c. -116.0 psf @ 6" o.c. Install per manufacturers details. For use in HVHZ Zones. 17796.3 1 1" Mechanical Lock Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-101.OPSF Other: -63.5 psf @ 24" o.c. -101.0 psf @ 6" o.c. Install per manufacturers details. For use in HVHZ Zones. Installation Instructions FL17796 RI II FL 17796 1.5 Nail Strip 24GA over Plywood - 2017 Code RR.pdf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL17796 RI AE FL 17796 1.5 Nail Strip 24GA over Plywood - 2017 Code RR.pdf Created by Independent Third Party: Yes 1 1/2" Snap Lock 24 Ga. over 16" Wide 1/2" Plywood Installation Instructions FL17796 R1 II FL 17796 1.5 Snap Lock 24GA SS over Plywood - 2017 Code RR.pdf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL17796 R1 AE FL 17796 1.5 Snap Lock 24GA SS over Pi wood - 2017 Code RR.pdf Created by Independent Third Party: Yes 1" Mechanical Lock 0.032" Aluminum 16" Wide over 1/2" Plywood Installation Instructions FU7796 RI II FL 17796 1.0 Mechanical Lock .032 or .040 Alum - 2017 Code RR.pdf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL17796 R1 AE FL 17796 1.0 Mechanical Lock .032 or .040 Alum - 2017 Code RR.pdf Created by Independent Third Party: Yes 117796.4 1 1" Nail Strip 11" Nail Strip 24 Ga. 16" Wide over 1/2" Plywood Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +N/A/-153.5PSF Other: -59.75 psf @ 16" o.c. -101.0 psf @ 6 3/4" o.c. -153.5 psf @ 6 3/4" 6.c. 12" o.c. Install per manufacturers details. Not for use in HVHZ Zones. Installation Instructions FL17796 RI II FL 17796 1.0 Nail Strip 24GA over 15 32 Pywood - 2017 Code RR.pdf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL17796 RI AE FL 17796 1.0 Nail Strip 24GA over 15 32 Plywood - 2017 Code RR.pdf Created by Independent Third Party: Yes 117796.5 1 1" Snap Lock 1 1" Snap Lock 24 Ga. 17" Wide 1/2" Plywood Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-131.OPSF other: -67.3 psf @ 24" o.c. -131.0 psf @ 6" o.c. Install per manufacturers details. For use in HVHZ Zones. Installation Instructions FL17796 R1 II FL 17796 1.0 Snap Lock 24GA SS over Plywood - 2017 Code RR.pd[ Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL17796 RI AE FL 17796 1.0 Snap Lock 24GA SS over P1Ywood - 2017 Code RR.g_df Created by Independent Third Party: Yes 17796.E 15V Crimp 26 Ga. 5V Crimp Roof Panel over Plywood wits of Use Installation Instructions App I � use in HVHZ: FL17796 RI II FL 17796 5V Crimp 24GA or 26GA Min, Thru Approved for use outside HVHZ: Yes Fastened over Plywood - 2017 Code RR.pff Impact Resistant: N/A Verified By: Locke Bowden, P.E. 49704 https://www.floridabuilding.org/pr/pr_app_dti.aspx?param=wGEVXQwtDgs%2bbt23mL8HofjjKv7zYVGsdytxRV640WTjfC3zOhF3BRA%3d%3d 2/3 11/19/2019 Florida Building Code Online Design Pressure: +N/A/-156.5PSF I Created by Independent Third Party: Yes Other: -108.5 psf @ 12" o.c. -156.5 psf @ 6" o.c. Install per Eva9uation Reports manufacturers details. For use in HVHZ Zones. FL17796 R1 AE FL 17796 5V Crimp 24GA or 26GA Min. Thru Fastened over Plywood - 2017 Code RR.pdf i Created by Independent Third Party: Yes i Back Next Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy atatement :: Accessibility. Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. 'Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emalls provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: ® ® ® e___ -zzc Credit• Safe securiMM TRICS• hftps://www.floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDgs%2bbt23mL8HofjjKv7zYVGsdytxRV640WTjfC3zOhF3BRA%3d%3d 3/3 4310 45t' Street Vero Beach, FL 32966 (772)257-5730 ,Florida Pfoduct Approval #17796, Sub -Category: Metal Roofing Method: 1:13, Compliant with Florida Building Code 2017 (6t' ed.) Compliant with Florida Product Approval Rule #8 61G20-3 Compliant Quality Assurance Program: keystone Cerifications FBC Sections:. 1504.3.2, 1506, 1507.4.3, 1517,1518.9, 1523.6.5.2.4 Underlayment: See Section 1507, Table 1507.1.1 24GA steel FOR HVHZ: ASTM A653 G90 FOR NON-HVHZ: ASTM A792 unpainted or painted w/ Valspar Fluropon See Table 1507.4.3(2) 15 %" Wide Female Rib: 1'W tall Male Rib: %" tall rib w/ slotted strip Panel Seam: Snap Lock Panel Fastener: Corrosion resistant Compliant; ALL to penetrate min. %" through plywood Min. 50ksi Through Panel Slot: (1) #12-11 -- 1" tall Pancake Type A In Pan of Panel: (2) #10-11 x 1" Eclipse Head Type A FOR HVHZ Construction 19/32" or greater APA Plywood or wood plank. In reroofing applications add 15/32" plywood where roof is less than 19/32" thick (min. 15/32") the attachment of the decking shall be no less than 813 annual ring shank nails@ 6"o.c. FOR NON-HVHZ Construction: min. 15/32" APA Plywood over supports at max. 24" o.c. Fire Barrier: Any approved fire barrier having a current NOA. -*Desien Pressure: I Panel Slot Fastener S@acinLr: I Panel Pan Fastener SRaacinR: -78.5 PSF 11" O.C. N/A -116 PSF 6 %11 O.C. 12" O.C. 24GA steel FOR HVHZ:-ASTM A653 690 FOR NON-HVHZ: ASTM A792 unpainted or painted wr/ Valspar Fluropon See Table 1507.4.3 (2) 16" Wide Rib: 1 %" Panel Seam: Snap Lock Roof Panel Clip:1500SNS, Fixed,18GA, 3 %" Long Min. 50ksi Corrosion Resistant Clip Fastener: (2) #12-11 Pancake Type A to penetrate min. %" thru plywood. FOR HVHZ Construction:19/32" or greater APA Plywood or wood plank. In reroofing applications add 15/32" plywood add 15/32" plywood where roof is less than 19/32" thick (min. 15/32") the attachment of the decking shall be no less than 8D annual ring shank nails @ 6"o.c. FOR NON-HVHZ Construction: mien. 15/32" :SPA Plywood over supports at max. 24" o.c. Fire Barrier: Any approved fire barrier having a current NOA. * Design Pressure: Clip Spacing: Fasteners per Clip: -86.0 PSF 24" O.C. 2 -109.5 PSF 12" O.C. 2 .116.0 6" O.C. 2 .03r-- or .040" Aluminum?, 3105 H-24 unpainted or painted with Valspar Fluropon conforming to FBC 2017 6" ed. Min. 22.7 ksi 16" Wide Rib Height: 1" Panel Seam: 180• Seam, Double Lock w/ mechanical seamer Roof Panel Clip: UC-3 Stainless Steel Butterfly Clip Assembly, Two -Piece Slider Corrosion Resistant Clip Fastener: (2) #12-11 x 1" Pancake Type A to penetrate min. %" thru plywood FOR HVHZ Construction: 19/32" or greater APA Plywood or wood plank. In reroofing applications add 15/32" plywood where roof is less than 19/32" thick (min. 15/32") the attachment of the decking shall be no less than 81) annual ring shank nails @ 6"o.c. FOR NON-HVHZ Construction: min. 15/32" APA Plywood over supports at max. 24" o.c. Fire Barrier: Any approved fire harrier having a current NOA. "Design Pressure: Clip Spacing: Fasteners per Clip: .63.5 PSF 24" O.C. 2 -101.0 PSF 6" O.C. 2 24GA Steel, conforming to FBC 2017 G' ed. Yield Strength: Min. 50 ksi Self -adhered roofing underlayment min. 40 mil thickness. 16" Wide Female Rib: I" tall klale Rib: %" tall rib w/ slotted strip Panel Seam: Snap Lock Panel Fastener: Corrosion Resistant Compliant; ALL to penetrate %" min. through plywood Through Panel Slot: (1) #10-13 x 1" GP Pancake Type A In Pan of Panel: (2) #10-11 x 1" Eclipse Head Type A Substrate: Min. 15/32" APA Plywood over supports at max. 2e o.c. Min. slope shall comply w/ FBC 2017 61 ed. "Design Pressure: Panel Slot Fastener Spacing: Panel Pan Fastener Spacing: -59.75 PSF 16" O.C. N/A -101.0 PSF 6 %" O.C. N/A -153.5 PSF 6 %" O.C. 3.2" O.C. FL 1,7796 1 Lbck 24GA• Roof Panel Over ••• NoAp'pon 24GA steel FOR HVHZ: ASTM A653 G90 FOR NON-HVHZ: ASTM A792 unpainted or painted w/ Valspar Fluropon See Table 1507.4.3 (2) 17" Wide Rib Height: 1" Panel Seam: Snap Lock Roof Panel Clips:1000SNS, Fixed, 18GA, 3 W Long Corrosion Resistant Clip Fastener: (2) #12-12 Pancake Head Type A to penetrate min. W through plywood Min. 50ksi FOR HVHZ-Construction: 19/32" or greater APA Plywood or wood plank. In reroofing applications add 15/32" plywood where roof is less than 19/32" thick (min.15/32") attachment of the decking shall be no less than 8D annual ring shank nails @ 6"o.c. FOR NON-HVHZ Construction: min.15/32" APA Plywood over supports at max. 24" o.c. Fire Barrier: Any approved fire barrier having a current NOA. Min. slope shall comply w/ FBC 2017 Wh ed. **Design Pressure: I CIiD Soacine: I Fasteners per Clio: 1 -67.3 PSF 1 24" O.C. 1 2 1 24GA steel FOR HVHZ: ASTM A653 G90 FOR NOR!-HVHZ: ASTM A792 unpainted or painted w/ Valspar Fluropon See Table 1507.4.3 (2) 24" Wide Rib Height: 3/8" major rib Min. 50ksi Fire Barrier: %" Georgia Pacific "Dens Deck" or approved equal. FOR HVHZ Construction: 19/32" or greater APA Plywood or wood plank. In reroofing applications add 15/32" plywood where roof Is less than 19/32" thick (min.15/32") the attachment of the decking shall be no less than 80 annual ring shank nails @ 6"o.c. FOR NON-HVHZ Construction: Min. 15/32" APA Plywood over supports at max. 24"o.c. Min. slope shall comply w/FBC 2017 61 ed. *'"Design Pressure: Fastener Pattern: Fastener Spacing: -108.5 PSF Panel Rib 12" O.C. -156.5 PSF Panel Rib 6" O.C. Reference ®ata: TAllrNUIYYK9330LI I;11V1.LUIJ=A MrtI r nrIANUIIV Vr 6:l Force Engineering & Testing (TST-5328) 72-0190T 07 TAS 125-03 (UL 580-061/UL 1897-122) Farabaugh Engineering & Testing.(TST-1564) T349-07 TAS 100.95 PRI Asphalt Technologies TAS 110-00 (ASTM G 155/ASTM B 117) Force Engineering & Testing (TST-5328) 72-0180T-07 TAS 125-03 (UL 580-061/1.11. 1897-122) Farabaugh Engineering & Testing (TST-1654) T107-07 TAS IOD-95 Force Engineering & Testing (TST-5328) 72-0191T-07 TAS 125-03 (UL 58D-061/UL 1897-122) Farabaugh Engineering & Testing (TST-1654) T232-07 TAS 100-95 Force Engineering & Testing (TST 5328) 72-0314T-06 UL 580-941/UL 1897-122 Farabaugh Engineering & Testing (TST-1654) T158-07 TAS 100-95 Force Engineering & Testing (TST-5328) 72-021OT-07 TAS 125-03 (UL 580-061/UL 1897-122) Farabaugh Engineering & Testing (TST-1654) T233-07 TAS 100-95 Force Engineering & Testing (TST-5328) 115-0172T-07 A-C TAS 125-03 (UL 5M061/UL 1897-1221 Farabaugh Engineering & Testing (TST 1654) T130-07 TAS 100-95 T215-08 TAS 10D-95 1, UL 580-94 test standard is equivalent to UL 580-06 test standards. Z UL 1897-98 test standard is equivalent to UL 1897-12 test standards. Limitations: 1. Underlayment to be compliance with current Florida Building Code (FBC)2017 6TM ed.. see Chart 1507.1.1 2. Minimum slope to be compliant with Florida Building Code 2017 0 ed., and per with Manufacturer's installation reference. 3. Products are compliant with State of Florida product approval per Rule 61G20-3. Compliance. Method: 1-1) 4. Engineering analysis for "project specific approval by local authority's w/Jurisdiction is allowed by other registered engineers. S. Fire classification is not part of this acceptance. shear diaphragm values are outsidethis report. 6. Support framing in compliance w/FBC 2017 6th ed., Chapter 22 Steel, Chapter 23 Wood and Chapter 16 Structural Loading. 7. This report does not imply warranty, installation, recommendedproduct use outside of this report. Certificate of Independence: Locke Bowden, P.E. does not have, not will acquire a financial interest in any company manufacturing or distributing products under this evaluation. Locke Bowden, P.E. is not owned, operatgA4J tVMitfNv4py any company, manufacturer or distributing products under report. Locke Bowden, P.E FL Reg. no. 49704 .0 10 STATE OF LORI�A••G�.`� 04,�'fir, AL %���� ATLANTIC LANTIC METAL II OF VERO BEACH, INC. 5V Crimp 24GA or 26GA Min. Thru Fastened over Plywood — INSTALLATION DETAILS 6-V GRiNIP EXPOSED FASTENER S�ISTENI 12" Q.C. %4A1N FIELD . b" O.C. PE, RI•11AETEIZ 5V CRIMP PANEL MEMBRANE h � N€ JILT A FASTENER 99 `- SUSSTRUCTURC- MATSWAL OMONS FW14 a° cNs PATH A 633 "1 ASTH A )7Z _ _.._... ' Vc CM PROWME FV L [l:SM CM= SEWS Tit PATCH PRACTIC+I r Auy VATERSN WDE, 49 -Pmr,Ti7J RU;iEST FACiA1G4i1C7N Cpii0b15 STEEL 26 Ii;CHMICALDATA j ./ 27-1/2- Ra-t:. Stock Pjuterial For 24` Coverage Note . AR Raciii 0.05 12NO V 99 Fixed Qverlap Ribs 26 For..24` Coverae� 24' Coverac 7/81 Adjustable -Center Rib -Ad jus taole C'nderlan Ribs ATLANTIC METAL II OF VERO BEACH, =. 6V Crimp 24GA or 26GA Min. Thru Fastened over Plywood — INSTALLATION DETAILS • TYPICAL DETAOLS RIDGE SV CRIMP PANEL, fu0FLASH FASTENER #9 /y TRH OUTSIDE TAPE SEALER CLOSURE FASTENE_RNG WATERPROOF SUBSTRUCTURE MEM$RANE Cb�SSE�'ai® OF RIDGE OVER WOOD DECk ISOMETRIC VIEW OF RIDGE OVER WOOD DECK ATLANTIC METAL II OF VERO BEACH, INC. 5V Crimp 24GA or 26GA Min. Thru Fastened over Plywood — INSTALLATION DETAILS . - 5-V MM.P PANEL - 30A� FELT ' FUII_SHEET IN VALLEY IN=E CLOSURE . - - - STFUP' W/ _URSTRAM' _ SEALANr ' - - B•4. VALLEY F'LASM➢170. h; B 1IYL T - -" APE Frr-to=r-J+ ilr 0.c 9-10 R 1'1%i IRAs R/WADU (b ;I. PA1 ei1 15/32• PLYWOOD 644EATHINO"COY OTHERS) [VALLEY ENDLAP 0 MJN.] 2a•.c.a �- Norwv. CoymC�. FASTENERPATTERN.AT VALLEY - 9-15,x 1 1/2 HWH W/NEOPRENE )MASHER f 12" 0,0.] 1/S"x1 CONT. BUTYL TAPE 5—V CRIMP.P;ANEL,. / '%E"'PLYV000 SHEATHNG [BY OTHERS] IF - 30#. FELT P.LYV/COD SHEATHING [BY OTHERS] RAKC FLASHING — 9-15 x 1 1/2 HWH Y1/NEOPRENE- WASHUR f12' O.C.j WOOD TRIM [BY OTHERS] ATLANTIC METAL II OF E'ER® BEACH, INC. GV Crimp 24GA or 26GA Min. Thru Fastened over Plywood — INSTALLATION DETAILS PREFUNIS4E7 WALL PANEL. -.. / .Gy OTN725j i 10.12 r I PANCAhY;' N[Ap �' , !AW OZ [ I2" 0^. t � iiriialiitip R/Ke IVJU QAT'Ir.v - �eUTTL TP.P` . PREFlhpJ{ED -5-v CRIMP PANEL PLYWOOD S EATONC-(N8CS1] PLI'MOD SHEATIMC [9Y_.Ot}teRSj $+15 s 1 1 2 IRCi %lIEC4TitYR WARI1 ocj 7C; do WATER `YF'SELC ldlN. 4B" WOE ® SLOP=D ROOF TO CONTINUE UP WALL TO RECLET $0 !3 FELT TldrnA;tFrb L 10-12 x 1 PANCAKE -HEAD SELF -TAPPER [12' O.C.] 5-V CRIMP PANEL 9-IS x 11�2 HiS'{ W/WPSFftR [6`PER PANEL] 30g'FELT INSIDE-- CLOSURE STRIP WITH 1JREr8ANE SEALANT' 1/8"x1" CONT. BUTYL TAPE i5/'32" PLYWOOD SHEATHING 111 I (BY OTHERS)' - I EAVE FLASHING WALL PANEL FASTENER ® 12" O.C. (BY OTHERS). WOOD 'BLOCKING `WALL PANEL (BY OTHERS) 24" O.C. . ' N0IANAL`COVERAtE .. . FASTENER PATTERN AT SAVE