Loading...
HomeMy WebLinkAboutStarters NOA NOA No.: 15-0922.05 Expiration Date: 08/09/21 Approval Date: 04/14/16 Page 1 of 4 MIAMI-DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T (786) 315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.gov/economy GAF 1 Campus Drive Parsippany, NJ 07054 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami-Dade County RER -Product Control Section to be used in Miami-Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Section (in Miami-Dade County) and/or the AHJ (in areas other than Miami-Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: GAF Pro-Start® Eave/Rake Starter Strip Shingles and WeatherBlockerTM Premium Eave/Rake Starter Strip Shingles LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami-Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews NOA No.14-1022.15 and consists of pages 1 through 4. The submitted documentation was reviewed by Gaspar J Rodriguez. NOA No.: 15-0922.05 Expiration Date: 08/09/21 Approval Date: 04/14/16 Page 2 of 4 ROOFING ASSEMBLY APPROVAL Category: Roofing Sub-Category: Asphalt Shingles Material: Laminate Deck Type: Wood 1. SCOPE This approves GAF Pro-Start® Eave/Rake Starter Strip Shingles and WeatherBlockerTM Premium Eave/Rake Starter Strip Shingles manufactured by GAF as described in Section 2 of this Notice of Acceptance, designed to comply with the High Velocity Hurricane Zone of the Florida Building Code. 2. PRODUCT DESCRIPTION Manufactured by Applicant Dimensions Test Specifications Product Description GAF Pro-Start® Eave/Rake Starter Strip Shingles Manufacturing Locations #1, 2, and 3 13" x 38" TAS 110 Prefabricated starter strip asphalt shingle. GAF WeatherBlockerTM Premium Eave/Rake Starter Strip Shingles Manufacturing Location #2 17" x 40" TAS 110 Prefabricated starter strip asphalt shingle. 2.1. MANUFACTURING LOCATIONS 1. Dallas, TX 2. Mt. Vernon, IN 3. Tuscaloosa, AL 2.2. EVIDENCE SUBMITTED Test Agency Test Identifier Test Name/Report Date PRI Asphalt Technologies, Inc. ELK-34-02-01 TAS 100 05/16/00 Underwriters Laboratories, Inc. 01NK06632 ASTM D 3462 02/01/01 94NK9632 TAS 107 03/29/00 00NK32754 ASTM D 3462 08/11/00 09CA06856 ASTM D 3462 05/15/09 10CA07264 ASTM D 3462 05/27/10 10NK11953 ASTM D 3462 10/29/10 NOA No.: 15-0922.05 Expiration Date: 08/09/21 Approval Date: 04/14/16 Page 3 of 4 3. LIMITATIONS 3.1 Fire classification is not part of this acceptance. Refer to a current Approved Roofing Materials Directory for fire ratings of this product. 3.2 Shall not be installed on roof mean heights in excess of 33 ft. 3.3 All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61G20-3 of the Florida Administrative Code. 4. INSTALLATION 4.1 Starter Strip Shingles shall be installed in compliance with Roofing Application Standard RAS 115. 4.2 The manufacturer shall provide clearly written application instructions. 5. LABELING Shingles shall bear the imprint or identifiable marking of the manufacturer's name or logo, city and state of manufacturing facility, and following statement: "Miami-Dade County Product Control Approved" or the Miami-Dade County Product Control Seal as shown below. 6. BUILDING PERMIT REQUIREMENTS: 6.1 Application for building permit shall be accompanied by copies of the following: 6.1.1 This Notice of Acceptance. 6.1.2 Any other documents required by Building Official or Applicable building code in order to properly evaluate the installation of this system. NOA No.: 15-0922.05 Expiration Date: 08/09/21 Approval Date: 04/14/16 Page 4 of 4 GAF PRO-START® Eave/Rake STARTER STRIP SHINGLES GAF WEATHERBLOCKERTM PREMIUM EAVE/RAKE STARTER STRIP SHINGLES END OF THIS ACCEPTANCE