HomeMy WebLinkAboutProposed Dock Plan View***NOTES*** - -- -
- LAYOUT PER ST LUCIE COUNTY PROPERTY APPRAISER MAP AND 6-4-20 SITE VISIT
- NEW 30x10 DOCK ADJACENT TO NEW SEAWALL AND UNDER 25% OF CANAL WIDTH
- 50' SURROUNDING PERIMETER BOTTOM AREA WAS IN -WATER INSPECTED ON 6-4-2020 AT LOW TIDE
AND IS BARREN OF ANY SEAGRASSES OR RESOURCES. ONLY MUDDY SAND BOTTOM IS PRESENT.
1
ADJACENT
SINGLE
FAMILY
RESIDENTIAL
JOSH PRINCE
120 RIOMAR CT
PORT ST LUCIE, FL 33452
PARCEL ID:
3419-575-0007-000-1
-40'
RIOMAR CT
ADJACENT
SINGLE
FAMILY
RESIDENTIAL
EX -CULVERT
W/ HEADWALL
"90MHW
30
10 C EXISTING SEAWALL �,T ° a E H yip
(TO REMAIN) lq'
DEAD-END FINGER CANAL
1 00'WIDE OFF OF
N FORK OF ST LUCIE RIVER
30x10 (300 SF) 4
MARGINAL DOCK c
TURBIDITY CURTAIN �' �
Permit Number
A r
56-387873-002-EE
PROPOSED DOCK P Southeast District y°
PLAN VIEW o
y
SCALE 1" = 30'
SCALE: 1' = W
Croushore Marine Engineering Inc. DATE: 05.0420
100 ANDROS ROAD, PALM SPRINGS, FLORIDA 33461 REVISED: 07.0320
PH (561) 951-6036
FL CERT OF AUTH #30254
� IDw.WN BY: CRC
JOSH PRINC
PORT ST LUCIE, FL P-1
PROPOSED DOCK
PLAN VIEW SHEET OF
***NOTES***
- LAYOUT PER ST LUCIE COUNTY PROPERTY APPRAISER MAP AND 6-4-20 SITE VISIT
NEW '30x10 DOCK ADJACENT TO NEW SEAWALL AND UNDER 25% OF CANAL WIDTH
- 50' SURROUNDING PERIMETER BOTTOM AREA WAS INSPECTED ON 6-4-2020 AT LOW TIDE AND IS
BARREN OF ANY SEAGRASSES OR RESOURCES. ONLY MUDDY SAND BOTTOM IS PRESENT.
NO $AV OBSERVED.
DECK BOARD NOT SHOWN FOR CLARITY
ADJACENT
SINGLE
FAMILY
RESIDENTIAL
DEAD-END FINGER CANAL
- 100' WIDE OFF OF
N FORK OF ST LUCIE RIVER
30x10 (300 SF)
MARGINAL DOCK
PROPOSED DOCK
PLAN VIEW
SCALE 1" = 30'
DATE, '._
Croushore Marine Engineering Inc.
DATE: 08.1620
100 ANDROS ROAD, PALM SPRINGS, FLORIDA 33461
PH (561) 951-6036
FL CERT OF AUTH #30254
CRC
RIOMAR CT
ADJACENT
SINGLE
FAMILY
RESIDENTIAL
/- EX-. CULVERT
W/ HE�11�
�is
V
I
eJ(uLQ0za
cl-0 CHRISTOPHER R. CROLISHORE, PE
FLORIDA PE # 74580.
JOSH PRINCE
PORT ST LUCIE, FL p_ j
PROPOSED DOCK
PLAN VIEW SHEET OF
` L
***NOTES***
— ALL WOOD TO BE SYP, GRADE #1 OR BETTER
— PILES TO BE 2.50 CCA, SUB —FRAMING TO BE 0.60 CCA
— DECK BOARDS TO BE TROPICAL DECKING
— ALL HARDWARE TO BE HDG, UNLESS NOTED
- 4" BOLT ASSEMBLY KIT INCLUDES: 3" FLAT WASHER AND 4" (ID) HEX NUT
— EXTERIOR STRINGERS CONNECTED TO 8" PILE W/ (1) 4" BOLT ASSEMBLY KIT
- CROSS —TIES CONNECTED TO 8" PILE W/ (2) 4" BOLT ASSEMBLY KITS
INTERIOR STRINGERS CONNECTED TO CROSS —TIES W/ SIMPSON H2.5A HURRICANE STRAPS
— DECKBOARD CONNECTED TO STRINGERS W/ CAMO 316 SS 2-3/8" EDGE DECK SCREWS
— 2 PER BOARD PER STRINGER
8" O MARINE PILE
@ 10' OCEW (TYP) 10, OC
2x6 TROPICAL
DECKING
CONTINUOUS EXISTING VINYL SEAWALL
W/ SEAWALL (TO REMAIN)
2x8 STRINGER 3'-6"
@ 22" OC
(MAX) (TYP) 1'-10" OC
I!
KIT (TYP)
3x10 CROSS -TIE 3'
MHW +.' MHW
MLW MLW
�'„ifl III'i1
MUDLINEloo
/\\H,,
/
01
\\/
PROPOSED DOCK
TYPICAL CROSS�SECTION VIEW
1
SCALE 1" = 3' CHRISTOPHER R. CROUSHORE, PE
FLORIDA PE # 74580
Croushore Marine Engineering Inc. SCALE:,"=3.
DATE: 0G1620 JOSH PRINCE
100 ANDROS ROAD, PALM SPRINGS, FLORIDA33461 PORT ST LUCIE, FL . CS-1
PH (561) 951-6036
FL CERT OF AUTH #30254 PROPOSED DOCK
DRAWN BY: CRC TYPICAL CROSS-SECTION VIEW SHEET OF
- ALL WOOD TO BE SYP, GRADE #1 OR BETTER
- ALL MARINE PILES TO BE 2.50 CCA PT
- ALL SUB -FRAMING TO BE 0.60 CCA PT
- ALL INSIDE PILES ARE BELOW DECK
- TURBIDITY CURTAIN TO BE USED DURING ALL PILE INSTALLATIONS.
CURTAIN LAYOUT
100' WIDE CANAL
3'
10, OC
3'-6"
SEAWALL
PROPOSED DOCK
TYPICAL CROSS-SECTION VIEW
SCALE 1" = 3'
SCALE: Croushore Marine Engineering Inc. DATE: �. �•=3'
100 ANDROS ROAD, PALM SPRINGS, FLORIDA 33461 REVISED: 07.03.20
PH (561) 95"036
FL CERT OF AUTH #30254
Br. CRC
SEE P-1 FOR TURBIDITY
p
4
4 Permit Number y
r
(56-387873-002-EE
Southe
�yvis`
JOSH PRINCE
PORT ST LUCIE, FL CS
PROPOSED DOCK
TYPICAL CROSS-SECTION VIEW SHEET20F2