Loading...
HomeMy WebLinkAboutCertification for Design Load ComplianceProject Name: Project Address: Planning & Development Services Department Building & Code Regulations Division 2300 Virginia Avenue, Fort Pierce, FL 34982 — (772) 462-1553 Certification for Design Load Compliance LA . >� DO; Prc'e Permit #: Occupancy Type: Construction Type: INSTRUCTIONS FOR USE: • This certification must be completed, signed, and sealed by the design professional of record. • Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following: o New Residences (single or multi -family) o Residential Addition o Any accessory structure requiring a building permit o Any non-residential structure. * Note: Form not required for interior renovations provided that no exterior structural elements are affected and certain minor building permits at the discretion of the local building official. Contact the # above for questions. DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply) 1. DESIGN CODE: Florida 2017 Building Code Sixth Edition with 20 NSA Supplements using ASCE 7-10 2. Structure Designed as (check one): X Enclosed Partially Enclosed Open 3. Risk Category: I X II III IV Exposure Category: B X C D 4. Design Wind Velocity 160 mph X ASD LRFD End Zone Width: 6 ft 5. Mean Roof Height 18 ft Roof Pitch: 6 :12 Parapet: NSA ft 6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings): +19.9; 31.E +19.9, -55.1 +19.9, -81.5 +34.s, -37.s +34.6, -46.a +28.5, -32.2 Zone 1: Zone 2: Zone 3: Zone 4: Zone 5: Garage: 7. Design Loads: Floor: 100 PSF Roof/Dead: 12 PSF Roof/Live: 30 Balcony: NSA PSF Dock: NIA PSF Deck: NSA PSF Stairs: NSA PSF Fence: NSA PSF Railings: NSA PSF 8. Were Shear Walls Considered For Structure? Yes X Not Applicable Explain Why Not: Aspect Ratio <4:1 9. Is A Continuous Load Path Provided? X Yes Not Applicable Explain Why Not: 10. Design Soil Bearing Pressure: 2500 PSF Soil Test Reports Submitted? Yes DESIGN PROFESSIONAL CERTIFICATION STATEMENT: I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie County. so c rtify that structur;# elements depicted on these plans provide adequate resistance to the design Date, and Donald J. Nuelle P.E. 52046 Print Name Cert # & Co. Cert Auth. Nuelle Engineering 11634 SW Rowena Street, Port St. Lucie, FL 34987 Company Name & Address Revised 12/07/2018