HomeMy WebLinkAboutCertification for Design Load ComplianceProject Name:
Project Address:
Planning & Development Services Department
Building & Code Regulations Division
2300 Virginia Avenue, Fort Pierce, FL 34982 — (772) 462-1553
Certification for Design Load Compliance
LA . >� DO; Prc'e
Permit #: Occupancy Type: Construction Type:
INSTRUCTIONS FOR USE:
• This certification must be completed, signed, and sealed by the design professional of record.
• Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following:
o New Residences (single or multi -family)
o Residential Addition
o Any accessory structure requiring a building permit
o Any non-residential structure.
* Note: Form not required for interior renovations provided that no exterior structural elements are affected and
certain minor building permits at the discretion of the local building official. Contact the # above for questions.
DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply)
1. DESIGN CODE: Florida 2017 Building Code Sixth Edition with 20 NSA Supplements using ASCE 7-10
2. Structure Designed as (check one): X Enclosed Partially Enclosed Open
3. Risk Category: I X II III IV Exposure Category: B X C D
4. Design Wind Velocity 160 mph X ASD LRFD End Zone Width: 6 ft
5. Mean Roof Height 18 ft Roof Pitch: 6 :12 Parapet: NSA ft
6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings):
+19.9; 31.E +19.9, -55.1 +19.9, -81.5 +34.s, -37.s +34.6, -46.a +28.5, -32.2
Zone 1: Zone 2: Zone 3: Zone 4: Zone 5: Garage:
7. Design Loads: Floor: 100 PSF Roof/Dead: 12 PSF Roof/Live: 30 Balcony: NSA PSF
Dock: NIA PSF Deck: NSA PSF Stairs: NSA PSF Fence: NSA PSF Railings: NSA PSF
8. Were Shear Walls Considered For Structure? Yes X Not Applicable Explain Why Not:
Aspect Ratio <4:1
9. Is A Continuous Load Path Provided? X Yes Not Applicable Explain Why Not:
10. Design Soil Bearing Pressure: 2500 PSF Soil Test Reports Submitted? Yes
DESIGN PROFESSIONAL CERTIFICATION STATEMENT:
I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to
comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie
County. so c rtify that structur;# elements depicted on these plans provide adequate resistance to the design
Date, and
Donald J. Nuelle P.E. 52046
Print Name Cert # & Co. Cert Auth.
Nuelle Engineering
11634 SW Rowena Street, Port St. Lucie, FL 34987
Company Name & Address
Revised 12/07/2018