Loading...
HomeMy WebLinkAboutEnergy CodesFORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: MW-57 TACOMA Builder Name: GHO BUILDERS Street: 9630 KNOLLWOOD LN Permit Office: ST. LUCIE COUNTY City, State, Zip: FORT PIERCE, FL, 34951 Permit Number. Owner. Jurisdiction: Design Location: FL, ST LUCIE CO INTL County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types (2435.9 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R=4.1 2132.60 ft' b. Frame - Wood, Adjacent R=11.0 303.33 ft' 3. Number of units, If multiple family 1 c. N/A R= ft' 4. Number of Bedrooms 3 d. NIA R= ft' 5. Is this a worst case? No 10. Ceiling Types (2521.0 sqft.) Insulation Area a. UnderAttic (Vented) R=40.0 2521.00 ft= 6. Conditioned floor area above grade (W) 2521 b. WA R= ft' Conditioned floor area below grade (ft') 0 c. WA R= ft' 11. Ducts R ft' 7. Windows(447.3 sqft.) Description Area a. Sup: Attic, Ret: Attic, AH: Main 6 683 a. U-Factor: Dbl, U=0.62 447.28 ft' SHGC: SHGC=0.26 b. U-Factor: NIA ft' 12. Cooling systems kBtu/hr Efficiency SHGC: a. Central Unit 56.0 SEER:16.00 c. U-Factor. N/A ft' SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor. NIA ft' a. Electric Strip Heat 34.0 COP:1.00 SHGC: Area Weighted Average Overhang Depth: 0.000 ft. Area Weighted Average SHGC: 0.260 14. Hot water systems 8. Floor Types (2521.0 sqft.) Insulation Area a. Electric Cap: 50 gallons a. Slab -On -Grade Edge Insulation R=0.0 2521.00 ft' b. Conservation features EF: 0.940 b. NIA R= ft' None c. NIA R= ft' 15. Credits Pstat Glass/Floor Area: 0.177 Total Proposed Modified Loads: 79.98 PASS Total Baseline Loads: 82.40 I hereby certify that the plans and specifications covered by Review of the plans and Srgr� this calculation are in comollance with the Florida Energy specifications covered by this O4ZIiE Code.0 calculation indicates compliance Code. with the Florida Energy an, PREPARED BY: Before construction is completed DATE: 9/10/2020 this building will be inspected for compliance with Section 553.908 # • Q I herebycertify tt]3t-4i� fy g, as des is in compliance Florida Statutes. with the Florida nergy Code. � COD ytls'1�° OWNER/AGENT: BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification bJ the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -seated in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). 9/9/2020 2:05 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: Building Type: Owner Name: # of Units: Builder Name: Permit Office: Jurisdiction: Family Type: New/Existing: Comment: MW 57 TACOMA User 1 GHO BUILDERS ST. LUCIE COUNTY Single-family New (From Plans) Bedrooms: 3 Conditioned Area: 2521 Total Stories: 1 Worst Case: No Rotate Angle: 0 Cross Ventilation: No Whole House Fan: No Address Type: Street Address Lot # Block/Subdivision: PlatBook: Street: 9630 KNOLLWOOD LN County: St. Lucie City, State, Zip: FORT PIERCE, FL, 34951 CLIMATE / V Design Location Design Temp TMY Site 97.6 % 2.5 % Int Design Temp Heating Design Daily Temp Winter Summer Degree Days Moisture Range FL, ST LUCIE CO INTL FL VERO BEACH_MUNI 39 90 70 75 299 58 Medium BLOCKS Number Name Area Volume 1 Blockl 2521 25714.2 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 Main 2521 25714.2 Yes 4 3 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio Main 215.3 ft 0 _ 2521 W -__- 0 0 1 ROOF / V # Type Roof Gable Roof Materials Area Area Color Red Solar SA Emitt Emilt Deck Pitch Barr Absor. Tested Tested Insul. (deg) 1 Hip Flat the/slate 2819 ft' 0 ft2 Medium N 0.4 N 0.9 No 0 26.6 ATTIC # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 2521 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Free Truss Type 1 Under Attic (Vented) Main 40 Blown 2521 ft= 0.1 Wood 9/9/2020 2:05 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT WALLS ZXAdjacent F1 Space Cavity Width Height Sheathing Framing Solar Below mt To Wall Type R-%/alue EtIn-Et In Area R Value r: ctioa_ Abso"rade.%_ N Exterior Concrete Block - Ext Insul Main 4.1 64 7 9 4 602.8 ft2 0 0 0.3 0 2 NE Exterior Concrete Block - Ext Insul Main 4.1 1 5 11 4 16.1 ft2 0 0 0.3 0 3 E Exterior Concrete Block - Ext Insul Main 4.1 63 6 9 4 591.9 ft2 0 0 0.3 0 4 SE Exterior Concrete Block - Ext Insul Main 4.1 2 10 11 4 32.1112 0 0 0.3 0 5 S Exterior Concrete Block - Ext Insul Main 4.1 36 1 9 4 336.8 ft2 0 0 0.3 0 6 SW Exterior Concrete Block - Ext Insul Main 4.1 3 1 9 4 28.8 ft2 0 0 0.3 0 7 W Exterior Concrete Block - Ext Insul Main 4.1 56 2 9 4 624.2 ft2 0 0 0.3 0 8 - Garage Frame -Wood Main 11 32 6 9 4 303.3 ft2 0 0.25 0.3 0 DOORS # Omt Door Type Space Storms U Value Width Height Area Ft In Ft In 1 S Wood Main None .39 6 7 42 ft= WINDOWS Orientation shown Is the entered. ProDosed orientation. / Wall Overhang V # Omt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation int Shade Screening 1 n 1 Metal Double (Clear) Yes 0.62 0.26 N 43.3 ft2 0 ft 0 In 0 ft 0 in None None 2 n 1 Metal Double (Clear) Yes 0.62 0.26 N 20.0 ft2 0 ft 0 In 0 ft 0 In None None 3 n 1 Metal Double (Clear) Yes 0.62 0.26 N 43.8 ft2 0 ft 0 in 0 ft 0 in None None 4 n 1 Metal Double (Clear) Yes 0.62 0.26 N 111.6 ft2 0 ft 0 In 0 ft 0 in None None 6 e 3 Metal Double (Clear) Yes 0.62 0.26 N 7.0 ft2 0 ft 0 In 0 ft 0 In None None 6 e 3 Metal Double (Clear) Yes 0.62 0.26 N 12.0 ft2 0 ft 0 In 0 ft 0 In None None 7 e 3 Metal Double (Clear) Yes 0.62 0.26 N 31.6 ft2 0 ft 0 In 0 ft 0 In None None 8 se 4 Metal Double (Clear) Yes 0.62 0.26 N 11.7 ft2 0 ft 0 in 0 ft 0 In None None 9 s 5 Metal Double (Clear) Yes 0.62 0.26 N 21.7 ft2 0 ft 0 In Oft 0 In None None 10 a 5 Metal Double (Clear) Yes 0.62 0.26 N 12.0 ft2 0 ft 0 In 0 ft 0 In None None 11 s 6 Metal Double (Clear) Yes 0.62 0.26 N 42.0 ft2 0 ft 0 in 0 ft 01n None None 12 sw 6 Metal Double (Clear) Yes 0.62 0.26 N 11.7 ft2 0 ft 0 In 0 ft 0 In None None 13 w 7 Metal Double (Clear) Yes 0.62 0.26 N 21.3 ft2 0 ft 0 In 0 ft 0 In None None 14 w 7 Metal Double (Clear) Yes 0.62 0.26 N 7.3 ft2 0 ft 0 In 0 ft 0 to None None 15 w 7 Metal Double (Clear) Yes 0.62 0.26 N 43.3 fF 0 ft 0 In 0 ft 0 In None None 16 W 7 Metal Double (Clear) Yes 0.62 0.26 N 7.0 ft2 0 ft 0 In 0 ft 0 in None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 689 ft2 689 ft2 64 it 9.3 ft 1 9/9/2020 2:05 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST RFPORT INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000454 3000 164.7 309.73 .1733 7 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block 1 Electric Strip Heat/ None COPA 34 kBtu/hr 1 _Ducts sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit! Split Singl SEER: 16 56 kBtu/hr cfm 0.7 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 EleWc None Garage 0.94 50 gal 62.3 gal 120 deg None _ SOLAR HOT WATER SYSTEM FSEC Cert # Company Name Collector System Model # Collector Model # Area Storage Volume FEF None None ff' DUCTS / — Supply — V # Location R-Value Area — Return — Air CFM 25 CFM25 Location Area Leakage Type Handler TOT OUT ON RLF HVAC # Heat Cool 1 Attic 6 683 ft' Attic 264 ft' Default Leakage Main (Default) (Default) 1 1 TEMPERATURES Programable Thermostat: Y Cooling Jan Feb r , Mar Heating Jan Feb [X1 Mar Venting Jan Feb [[[[�XXXIII) Mar Ceiling Fans: Apr Ma un Jul r Auge Apr IJun Jul E Aug l Sep j May ni Apr May Jun Jul 111 Aug t Sep lxJ Oct Nov Oct Nov Oct Nov r , Dec (X] Dec [[[ 111 Dec g/9/2020 2:05 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 6 FORM R405 2017 INPUT SUMMARY CHECKLIST REPORT Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default 8 W/s .% 0 ft= 0 ft 0.3 Main 9/9/2020 2:05 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 5 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 97 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 c) AHU location Main 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 3 13. Cooling system: Capacity 56.0 a) Split system SEER 16.0 5. Is this a worst case? (yes/no) 5. No b) Single package SEER c) Ground/water source SEER/COP 6. Conditioned floor area (sq. ft.) 6. 2521 d) Room unit/PTAC EER. e) Other 7. Windows, type and area a) U-factor:(weighted average) 7a. 0.620 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.260 14. Heating system: Capacity 34.0 c) Area 7c. 447.3 a) Split system heat pump HSPF b) Single package heat pump HSPF 8. Skylights c) Electric resistance COP 1.0 a) U-factor:(weighted average) 8a. NA d) Gas furnace, natural gas AFUE b) Solar Heat Gain Coefficient (SHGC) 8b. NA e) Gas furnace, LPG AFUE f) Other 9. Floor type, insulation level: a) Slab -on -grade (R-value) b) Wood, raised (R-value) c) Concrete, raised (R-value) 10. Wall type and insulation: A. Exterior: 1. Wood frame (Insulation R-value) .2. Masonry (Insulation R-value) B. Adjacent: 1. Wood frame (Insulation R-value) 2. Masonry (Insulation R-value) 11. Ceiling type and insulation level a) Under attic b) Single assembly c) Knee walls/skylight walls d) Radiant barrier installed 9a. 0.0 9b. 9c. 10A1. 10A2. 4.1 15. Water heating system a) Electric resistance EF 0.94 b) Gas fired, natural gas EF c) Gas fired, LPG EF d) Solar system with tank EF e) Dedicated heat pump with tank EF f) Heat recovery unit HeatRec% g) Other 1061. 11.0 1062. 16. HVAC credits claimed (Performance Method) a) Ceiling fans 11a. 40.0 b) Cross ventilation No 11b. c) Whole house fan No 11c. d) Multizone cooling credit 1ld. No e) Multizone heating credit f) Programmable thermostat Yes 'Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied With the Florida Building Code, Energy Conservation, through the above energy saving features which will be installs (or exceeded) In this home before final inspection. Otherwise, a new EPL display card wili be completed based Jon installed code compliant features. Builder Address of New Home: Date: II1 D I ?,.Pzo City/FL Zip: FORT PIERCE, FL 34951 9/9/2020 2:05:41 PM EnergyGaugeO USA 6.0.04 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 -- wrightsoft. Load Short Form Entire House Project Information For: MW-57 9630 KNOLLWOOD LN, FORT PIERCE, FL 34951 Job: Date: Sep 01, 2020 By: -Design Information Htg Clg Infiltration Outside db (°F) 43 92 Method Simplified Inside db(°F) 70 72 Construction quality Semi -tight Design TO (OF) 27 20 Fireplaces 0 Daily range - L Inside humidity (%) 30 50 Moisture difference (gr/lb) 0 63 HEATING EQUIPMENT COOLING EQUIPMENT Make Make Lennox Trade Trade 16ACX SERIES Model Cond 16ACX-060-230A AHRI ref Coil CBA25UHV-060-230 AHRI ref 202540573 Efficiency 100 EFF Efficiency 12.0 EER, Heating input 10.1 kW Sensible cooling Heating output 34434 Btuh Latent cooling Temperature rise 16 OF Total cooling Actual air flow 1900 cfm Actual air flow Air flow factor 0.056 cfm/Btuh Air flow factor Static pressure 0 in H2O Static pressure Space thermostat Load sensible heat ratio 16 SEER 39200 Btuh 16800 Btuh 56000 Btuh 1900 cfm 0.052 cfm/Btuh 0 in H2O 0.70 ROOM NAME Area (ft2) Htg load (Btuh) Clg load (Btuh) Htg AVF (cfm) Cig AVF (cfm) MASTER SUITE 333 6217 6029 349 312 HIS WIC 53 893 417 50 22 MASTER BATH 159 1672 1818 94 94 HER WIC 74 62 263 3 14 DEN 199 3840 3092 215 160 FOYER 86 1550 1290 87 67 DINING 161 2686 2631 151 136 UTILITY 53 68 849 4 44 BATH 2 58 1012 1059 57 55 BED 2 200 2001 3165 112 164 BED'3 175 1900 3103 107 161 BATH 3 58 1679 1248 94 65 REAR VEST 45 1196 957 67 50 NOOK 106 3723 3412 209 177 KITCHEN 220 185 1678 10 87 r-10CAT 13RA Anc A9Cn coon nAG nGQ I\ITI YGJ -TJVV JVVV G-fJ GJJ Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-Sop-09 13:11:49 +C wrightsoft• Rlght-Suile® Universal 2012 12.1.05 RSU02818 Page 1 lei dk C:IUsersUasonlDocuments%Wrightsoft HVACIMW-57 TACOMA.rup Cafc = MJ8 Front Door faces: S U I ILI IT nRLL MECH yL 39 jzV 506 V o 328 115 28 14 17 Entire House 2536 33878 36694 1900 1900 Other equip loads 0 0 Equip. @ 0.97 RSM 35483 Latent cooling 15782 Tn*rAI0 caner �nnn ennn wf�w G11.7V JJVIV VILVJ I.7VV 1VVV Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020Sep-0913:11:49 �. wrightSOf' RlghtSulteQUniversal 201212.1.05RSU02818 Paget A& C:1UseraUasonWoeumento Wrightsoft HVACWW-57 TACOMA rup Cale - MJB Front Door faces: 8 +�- wrightsoft° Project Summary Entire House Project Information For: MW-57 9630 KNOLLWOOD LN, FORT PIERCE, FL 34951 Notes: Job: Date: Sep 01, 2020 By: Design Information Weather: Vero Beach Municipal AP, FL, US Winter Design Conditions Summer Design Conditions Outside db 43 OF Outside db 92 OF Inside db 70 OF Inside db 72 OF Design TD 27 OF Design TD 20 OF Daily range L Relative humidity 50 % Moisture difference 63 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 28126 Btuh Structure 29485 Btuh Ducts 5751 Btuh Ducts 7210 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 33878 Btuh Use manufacturer's data n Rate/swing, multiplier 0.97 Infiltration Equipment sensible load 35483 Btuh Method Construction quality Fireplaces Simplified Semi -tight 0 Heating Cooling Area (ft2) 2536 2536 Volume (f 3) 25668 25668 Air changes/hour 0.22 0.11 EgUIv. AVF (cfm) 94 47 Heating Equipment Summary Make Trade Model AHRI ref Efficiency 100 EFF Heating input 10.1 kW Heating output 34434 Btuh Temperature rise 16 OF Actual air flow 1900 cfm Air flow factor 0.056 cfm/Btuh Static pressure 0 in H2O Space. thermostat Latent Cooling Equipment Load Sizing Structure 13118 Btuh Ducts 2663 Btuh Central vent (0 cfm) 0 Btuh Equipment latent load 15782 Btuh Equipment total load 51265 Btuh Req. total capacity at 0.70 SHR 4.2 ton Cooling Equipment Summary Make Lennox Trade 16ACX SERIES Cond 16ACX-060-230A Coil CBA25UHV-060-230 AHRI ref 202540573 Efficiency 12.0 EER, 16 SEER Sensible cooling 39200 Btuh Latent cooling 16800 Btuh Total cooling 56000 Btuh Actual air flow 1900 cfm Air flow factor 0.052 cfm/Btuh Static pressure 0 in H2O Load sensible heat ratio 0.70 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. C wri hltSoft• 2020-Sop-0913:11Ag - 9 RlghtSullom Universal 12.1.05 RSU02818 Page 1 R"� C:1UsersWasonlDocumenls%Wrighlsoft HVACIMW-57 TACOMA.rup Calc = MJ8 Front Door faces: 8 OVERED LMAI �Na 6z646 NOOK 65 CFM Ir�L1 12 22CFM CFM lox 10,18 181 CFM 9Y 3 r GREAT ROOM sxeI O 87 CFM 0. 6•. 0 4-� ML 12x12x 203 Ca MT 10z 10z8 BEDROOM 2 184CFM AHU 5-TON 6-TON `. 6x 17 r u. I BCTON 2 CAR GARAGE GHO HOMES MW-57 9630 KNOLLWOOD LN FORT PIERCE, FL 54951 LDINING COVERED PORCH I� I� L------� T-STAT SHALL BE WITHIN 3FEET HORIZONTALLY OF MAIN RETURN DO NOT SCALE PLANS MASTER SUITE 121 3CFM I 12 CFM J x9mi� to WIC 112- W! 12'O FLEX 0x6x4 1 22 CFM —8xx88x6 74 CFM MASTER BATH 10x 10x8 160 CFM DEN