HomeMy WebLinkAboutEnergy CodesFORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: MW-57 TACOMA
Builder Name: GHO BUILDERS
Street: 9630 KNOLLWOOD LN
Permit Office: ST. LUCIE COUNTY
City, State, Zip: FORT PIERCE, FL, 34951
Permit Number.
Owner.
Jurisdiction:
Design Location: FL, ST LUCIE CO INTL
County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing New (From Plans)
9. Wall Types (2435.9 sqft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Ext Insul, Exterior
R=4.1 2132.60 ft'
b. Frame - Wood, Adjacent
R=11.0 303.33 ft'
3. Number of units, If multiple family 1
c. N/A
R= ft'
4. Number of Bedrooms 3
d. NIA
R= ft'
5. Is this a worst case? No
10. Ceiling Types (2521.0 sqft.)
Insulation Area
a. UnderAttic (Vented)
R=40.0 2521.00 ft=
6. Conditioned floor area above grade (W) 2521
b. WA
R= ft'
Conditioned floor area below grade (ft') 0
c. WA
R= ft'
11. Ducts
R ft'
7. Windows(447.3 sqft.) Description Area
a. Sup: Attic, Ret: Attic, AH: Main
6 683
a. U-Factor: Dbl, U=0.62 447.28 ft'
SHGC: SHGC=0.26
b. U-Factor: NIA ft'
12. Cooling systems
kBtu/hr Efficiency
SHGC:
a. Central Unit
56.0 SEER:16.00
c. U-Factor. N/A ft'
SHGC:
13. Heating systems
kBtu/hr Efficiency
d. U-Factor. NIA ft'
a. Electric Strip Heat
34.0 COP:1.00
SHGC:
Area Weighted Average Overhang Depth: 0.000 ft.
Area Weighted Average SHGC: 0.260
14. Hot water systems
8. Floor Types (2521.0 sqft.) Insulation Area
a. Electric
Cap: 50 gallons
a. Slab -On -Grade Edge Insulation R=0.0 2521.00 ft'
b. Conservation features
EF: 0.940
b. NIA R= ft'
None
c. NIA R= ft'
15. Credits
Pstat
Glass/Floor Area: 0.177 Total Proposed Modified Loads: 79.98
PASS
Total Baseline Loads: 82.40
I hereby certify that the plans and specifications covered by
Review of the plans and
Srgr�
this calculation are in comollance with the Florida Energy
specifications covered by this
O4ZIiE
Code.0
calculation indicates compliance
Code.
with the Florida Energy
an,
PREPARED BY:
Before construction is completed
DATE: 9/10/2020
this building will be inspected for
compliance with Section 553.908
# • Q
I herebycertify tt]3t-4i�
fy g, as des is in compliance
Florida Statutes.
with the Florida nergy Code.
�
COD ytls'1�°
OWNER/AGENT:
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification bJ the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -seated in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
9/9/2020 2:05 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 5
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title:
Building Type:
Owner Name:
# of Units:
Builder Name:
Permit Office:
Jurisdiction:
Family Type:
New/Existing:
Comment:
MW 57 TACOMA
User
1
GHO BUILDERS
ST. LUCIE COUNTY
Single-family
New (From Plans)
Bedrooms: 3
Conditioned Area: 2521
Total Stories: 1
Worst Case: No
Rotate Angle: 0
Cross Ventilation: No
Whole House Fan: No
Address Type: Street Address
Lot #
Block/Subdivision:
PlatBook:
Street: 9630 KNOLLWOOD LN
County: St. Lucie
City, State, Zip: FORT PIERCE,
FL, 34951
CLIMATE
/
V Design Location
Design Temp
TMY Site 97.6 % 2.5 %
Int Design Temp Heating Design Daily Temp
Winter Summer Degree Days Moisture Range
FL, ST LUCIE CO INTL FL VERO BEACH_MUNI 39 90
70 75 299 58 Medium
BLOCKS
Number
Name
Area Volume
1
Blockl
2521 25714.2
SPACES
Number
Name
Area Volume Kitchen Occupants
Bedrooms InfilID Finished Cooled Heated
1
Main
2521 25714.2 Yes 4
3 1 Yes Yes Yes
FLOORS
#
Floor Type
Space Perimeter R-Value
Area Tile Wood Carpet
1 Slab -On -Grade Edge Insulatio Main 215.3 ft 0
_
2521 W -__- 0 0 1
ROOF
/
V #
Type
Roof Gable Roof
Materials Area Area Color
Red Solar SA Emitt Emilt Deck Pitch
Barr Absor. Tested Tested Insul. (deg)
1
Hip Flat the/slate 2819 ft' 0 ft2 Medium
N 0.4 N 0.9 No 0 26.6
ATTIC
#
Type
Ventilation Vent Ratio (1 in)
Area RBS IRCC
1
Full attic
Vented 150 2521 ft2 N N
CEILING
#
Ceiling Type
Space R-Value Ins Type Area Framing Free Truss Type
1
Under Attic (Vented)
Main 40 Blown
2521 ft= 0.1 Wood
9/9/2020 2:05 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 5
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
WALLS
ZXAdjacent
F1
Space
Cavity Width Height
Sheathing Framing Solar Below
mt
To
Wall
Type
R-%/alue EtIn-Et In
Area
R Value r: ctioa_ Abso"rade.%_
N
Exterior
Concrete Block - Ext Insul
Main
4.1 64
7 9
4
602.8 ft2
0
0
0.3
0
2
NE
Exterior
Concrete Block - Ext Insul
Main
4.1 1
5 11
4
16.1 ft2
0
0
0.3
0
3
E
Exterior
Concrete Block - Ext Insul
Main
4.1 63
6 9
4
591.9 ft2
0
0
0.3
0
4
SE
Exterior
Concrete Block - Ext Insul
Main
4.1 2
10 11
4
32.1112
0
0
0.3
0
5
S
Exterior
Concrete Block - Ext Insul
Main
4.1 36
1 9
4
336.8 ft2
0
0
0.3
0
6
SW
Exterior
Concrete Block - Ext Insul
Main
4.1 3
1 9
4
28.8 ft2
0
0
0.3
0
7
W
Exterior
Concrete Block - Ext Insul
Main
4.1 56
2 9
4
624.2 ft2
0
0
0.3
0
8
-
Garage
Frame -Wood
Main
11 32
6 9
4
303.3 ft2
0
0.25
0.3
0
DOORS
#
Omt
Door Type Space
Storms
U Value
Width
Height
Area
Ft
In
Ft In
1
S
Wood Main
None
.39
6
7
42 ft=
WINDOWS
Orientation shown Is the entered. ProDosed orientation.
/
Wall
Overhang
V
#
Omt ID
Frame
Panes NFRC
U-Factor SHGC
Imp
Area
Depth
Separation
int Shade
Screening
1
n 1
Metal
Double (Clear)
Yes
0.62 0.26
N
43.3 ft2
0 ft 0 In
0 ft 0 in
None
None
2
n 1
Metal
Double (Clear)
Yes
0.62 0.26
N
20.0 ft2
0 ft 0 In
0 ft 0 In
None
None
3
n 1
Metal
Double (Clear)
Yes
0.62 0.26
N
43.8 ft2
0 ft 0 in
0 ft 0 in
None
None
4
n 1
Metal
Double (Clear)
Yes
0.62 0.26
N
111.6 ft2
0 ft 0 In
0 ft 0 in
None
None
6
e 3
Metal
Double (Clear)
Yes
0.62 0.26
N
7.0 ft2
0 ft 0 In
0 ft 0 In
None
None
6
e 3
Metal
Double (Clear)
Yes
0.62 0.26
N
12.0 ft2
0 ft 0 In
0 ft 0 In
None
None
7
e 3
Metal
Double (Clear)
Yes
0.62 0.26
N
31.6 ft2
0 ft 0 In
0 ft 0 In
None
None
8
se 4
Metal
Double (Clear)
Yes
0.62 0.26
N
11.7 ft2
0 ft 0 in
0 ft 0 In
None
None
9
s 5
Metal
Double (Clear)
Yes
0.62 0.26
N
21.7 ft2
0 ft 0 In
Oft 0 In
None
None
10
a 5
Metal
Double (Clear)
Yes
0.62 0.26
N
12.0 ft2
0 ft 0 In
0 ft 0 In
None
None
11
s 6
Metal
Double (Clear)
Yes
0.62 0.26
N
42.0 ft2
0 ft 0 in
0 ft 01n
None
None
12
sw 6
Metal
Double (Clear)
Yes
0.62 0.26
N
11.7 ft2
0 ft 0 In
0 ft 0 In
None
None
13
w 7
Metal
Double (Clear)
Yes
0.62 0.26
N
21.3 ft2
0 ft 0 In
0 ft 0 In
None
None
14
w 7
Metal
Double (Clear)
Yes
0.62 0.26
N
7.3 ft2
0 ft 0 In
0 ft 0 to
None
None
15
w 7
Metal
Double (Clear)
Yes
0.62 0.26
N
43.3 fF
0 ft 0 In
0 ft 0 In
None
None
16
W 7
Metal
Double (Clear)
Yes
0.62 0.26
N
7.0 ft2
0 ft 0 In
0 ft 0 in
None
None
GARAGE
#
Floor Area
Ceiling Area
Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1
689 ft2
689 ft2
64 it
9.3 ft
1
9/9/2020 2:05 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 5
FORM R405-2017 INPUT SUMMARY CHECKLIST RFPORT
INFILTRATION
# Scope Method
SLA
CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse Proposed ACH(50)
.000454
3000 164.7 309.73 .1733
7
HEATING SYSTEM
# System Type
Subtype
Speed Efficiency Capacity
Block
1 Electric Strip Heat/
None
COPA 34 kBtu/hr
1
_Ducts
sys#1
COOLING SYSTEM
# System Type
Subtype
Subtype Efficiency Capacity Air Flow
SHR Block
Ducts
1 Central Unit!
Split
Singl SEER: 16 56 kBtu/hr cfm
0.7 1
sys#1
HOT WATER SYSTEM
# System Type SubType
Location
EF Cap Use SetPnt
Conservation
1 EleWc None
Garage
0.94 50 gal 62.3 gal 120 deg
None
_
SOLAR HOT WATER SYSTEM
FSEC
Cert # Company Name
Collector
System Model # Collector Model # Area
Storage
Volume
FEF
None None
ff'
DUCTS
/ — Supply —
V # Location R-Value Area
— Return — Air CFM 25 CFM25
Location Area Leakage Type Handler TOT OUT
ON RLF
HVAC #
Heat Cool
1 Attic 6 683 ft'
Attic
264 ft' Default Leakage Main (Default) (Default)
1 1
TEMPERATURES
Programable Thermostat: Y
Cooling Jan Feb r , Mar
Heating Jan Feb [X1 Mar
Venting Jan Feb [[[[�XXXIII) Mar
Ceiling Fans:
Apr Ma un Jul r Auge
Apr IJun Jul E Aug l Sep
j May ni
Apr May Jun Jul 111 Aug t Sep lxJ
Oct Nov
Oct Nov
Oct Nov
r , Dec
(X] Dec
[[[ 111 Dec
g/9/2020 2:05 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 6
FORM R405 2017 INPUT SUMMARY CHECKLIST REPORT
Thermostat Schedule:
HERS 2006
Reference
Hours
Schedule Type
1
2
3
4
5
6
7
8
9
10
11
12
Cooling (WD)
AM
78
78
78
78
78
78
78
78
80
80
80
80
PM
80
80
78
78
78
78
78
78
78
78
78
78
Cooling (WEH)
AM
78
78
78
78
78
78
78
78
78
78
78
78
PM
78
78
78
78
78
78
78
78
78
78
78
78
Heating(WD)
AM
66
66
66
66
66
68
68
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
66
66
Heating (WEH)
AM
66
66
66
66
66
68
68
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
66
66
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default 8 W/s
.%
0 ft=
0 ft
0.3
Main
9/9/2020 2:05 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 5
2017 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 97
The lower the Energy Performance Index, the more efficient the home.
1. New home or, addition
1. New (From Plans)
12. Ducts, location & insulation level
a) Supply ducts
R
6.0
2. Single-family or multiple -family
2. Single-family
b) Return ducts
R
6.0
c) AHU location
Main
3. No. of units (if multiple -family)
3.
1
4. Number of bedrooms
4.
3
13. Cooling system:
Capacity
56.0
a) Split system
SEER
16.0
5. Is this a worst case? (yes/no)
5.
No
b) Single package
SEER
c) Ground/water source SEER/COP
6. Conditioned floor area (sq. ft.)
6.
2521
d) Room unit/PTAC
EER.
e) Other
7. Windows, type and area
a) U-factor:(weighted average)
7a.
0.620
b) Solar Heat Gain Coefficient (SHGC)
7b.
0.260
14. Heating system:
Capacity
34.0
c) Area
7c.
447.3
a) Split system heat pump
HSPF
b) Single package heat pump HSPF
8. Skylights
c) Electric resistance
COP
1.0
a) U-factor:(weighted average)
8a.
NA
d) Gas furnace, natural gas
AFUE
b) Solar Heat Gain Coefficient (SHGC)
8b.
NA
e) Gas furnace, LPG
AFUE
f) Other
9. Floor type, insulation level:
a) Slab -on -grade (R-value)
b) Wood, raised (R-value)
c) Concrete, raised (R-value)
10. Wall type and insulation:
A. Exterior:
1. Wood frame (Insulation R-value)
.2. Masonry (Insulation R-value)
B. Adjacent:
1. Wood frame (Insulation R-value)
2. Masonry (Insulation R-value)
11. Ceiling type and insulation level
a) Under attic
b) Single assembly
c) Knee walls/skylight walls
d) Radiant barrier installed
9a. 0.0
9b.
9c.
10A1.
10A2. 4.1
15. Water heating system
a) Electric resistance EF 0.94
b) Gas fired, natural gas EF
c) Gas fired, LPG EF
d) Solar system with tank EF
e) Dedicated heat pump with tank EF
f) Heat recovery unit HeatRec%
g) Other
1061. 11.0
1062.
16. HVAC credits claimed (Performance Method)
a) Ceiling fans
11a. 40.0
b) Cross ventilation No
11b.
c) Whole house fan No
11c.
d) Multizone cooling credit
1ld. No
e) Multizone heating credit
f) Programmable thermostat Yes
'Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
I certify that this home has complied With the Florida Building Code, Energy Conservation, through the above energy
saving features which will be installs (or exceeded) In this home before final inspection. Otherwise, a new EPL
display card wili be completed based Jon installed code compliant features.
Builder
Address of New Home:
Date: II1 D I ?,.Pzo
City/FL Zip: FORT PIERCE, FL 34951
9/9/2020 2:05:41 PM EnergyGaugeO USA 6.0.04 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
-- wrightsoft. Load Short Form
Entire House
Project Information
For: MW-57
9630 KNOLLWOOD LN, FORT PIERCE, FL 34951
Job:
Date: Sep 01, 2020
By:
-Design Information
Htg Clg Infiltration
Outside db (°F) 43 92 Method Simplified
Inside db(°F) 70 72 Construction quality Semi -tight
Design TO (OF) 27 20 Fireplaces 0
Daily range - L
Inside humidity (%) 30 50
Moisture difference (gr/lb) 0 63
HEATING EQUIPMENT
COOLING EQUIPMENT
Make
Make Lennox
Trade
Trade 16ACX SERIES
Model
Cond 16ACX-060-230A
AHRI ref
Coil CBA25UHV-060-230
AHRI ref 202540573
Efficiency
100 EFF
Efficiency 12.0 EER,
Heating input
10.1
kW
Sensible cooling
Heating output
34434
Btuh
Latent cooling
Temperature rise
16
OF
Total cooling
Actual air flow
1900
cfm
Actual air flow
Air flow factor
0.056
cfm/Btuh
Air flow factor
Static pressure
0
in H2O
Static pressure
Space thermostat
Load sensible heat ratio
16 SEER
39200 Btuh
16800 Btuh
56000 Btuh
1900 cfm
0.052 cfm/Btuh
0 in H2O
0.70
ROOM NAME
Area
(ft2)
Htg load
(Btuh)
Clg load
(Btuh)
Htg AVF
(cfm)
Cig AVF
(cfm)
MASTER SUITE
333
6217
6029
349
312
HIS WIC
53
893
417
50
22
MASTER BATH
159
1672
1818
94
94
HER WIC
74
62
263
3
14
DEN
199
3840
3092
215
160
FOYER
86
1550
1290
87
67
DINING
161
2686
2631
151
136
UTILITY
53
68
849
4
44
BATH 2
58
1012
1059
57
55
BED 2
200
2001
3165
112
164
BED'3
175
1900
3103
107
161
BATH 3
58
1679
1248
94
65
REAR VEST
45
1196
957
67
50
NOOK
106
3723
3412
209
177
KITCHEN
220
185
1678
10
87
r-10CAT 13RA
Anc
A9Cn
coon
nAG
nGQ
I\ITI YGJ -TJVV JVVV G-fJ GJJ
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
2020-Sop-09 13:11:49
+C wrightsoft• Rlght-Suile® Universal 2012 12.1.05 RSU02818 Page 1
lei dk C:IUsersUasonlDocuments%Wrightsoft HVACIMW-57 TACOMA.rup Cafc = MJ8 Front Door faces: S
U I ILI IT nRLL
MECH
yL
39
jzV
506
V o
328
115
28
14
17
Entire House
2536
33878
36694
1900
1900
Other equip loads
0
0
Equip. @ 0.97 RSM
35483
Latent cooling
15782
Tn*rAI0
caner
�nnn
ennn
wf�w G11.7V JJVIV VILVJ I.7VV 1VVV
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
2020Sep-0913:11:49
�. wrightSOf' RlghtSulteQUniversal 201212.1.05RSU02818 Paget
A& C:1UseraUasonWoeumento Wrightsoft HVACWW-57 TACOMA rup Cale - MJB Front Door faces: 8
+�- wrightsoft° Project Summary
Entire House
Project Information
For: MW-57
9630 KNOLLWOOD LN, FORT PIERCE, FL 34951
Notes:
Job:
Date: Sep 01, 2020
By:
Design Information
Weather: Vero Beach Municipal AP, FL, US
Winter Design Conditions
Summer Design Conditions
Outside db
43
OF
Outside db
92 OF
Inside db
70
OF
Inside db
72 OF
Design TD
27
OF
Design TD
20 OF
Daily range
L
Relative humidity
50 %
Moisture difference
63 gr/lb
Heating Summary
Sensible Cooling Equipment Load Sizing
Structure
28126
Btuh
Structure
29485 Btuh
Ducts
5751
Btuh
Ducts
7210 Btuh
Central vent (0 cfm)
0
Btuh
Central vent (0 cfm)
0 Btuh
Humidification
0
Btuh
Blower
0 Btuh
Piping
0
Btuh
Equipment load
33878
Btuh
Use manufacturer's data
n
Rate/swing, multiplier
0.97
Infiltration
Equipment sensible load
35483 Btuh
Method
Construction quality
Fireplaces
Simplified
Semi -tight
0
Heating Cooling
Area (ft2)
2536 2536
Volume (f 3)
25668 25668
Air changes/hour
0.22 0.11
EgUIv. AVF (cfm)
94 47
Heating Equipment Summary
Make
Trade
Model
AHRI ref
Efficiency
100 EFF
Heating input
10.1
kW
Heating output
34434
Btuh
Temperature rise
16
OF
Actual air flow
1900
cfm
Air flow factor
0.056
cfm/Btuh
Static pressure
0
in H2O
Space. thermostat
Latent Cooling Equipment Load Sizing
Structure
13118 Btuh
Ducts
2663 Btuh
Central vent (0 cfm)
0 Btuh
Equipment latent load
15782 Btuh
Equipment total load
51265 Btuh
Req. total capacity at 0.70 SHR
4.2 ton
Cooling Equipment Summary
Make Lennox
Trade 16ACX SERIES
Cond 16ACX-060-230A
Coil CBA25UHV-060-230
AHRI ref 202540573
Efficiency 12.0 EER,
16 SEER
Sensible cooling
39200
Btuh
Latent cooling
16800
Btuh
Total cooling
56000
Btuh
Actual air flow
1900
cfm
Air flow factor
0.052
cfm/Btuh
Static pressure
0
in H2O
Load sensible heat ratio
0.70
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
C wri hltSoft• 2020-Sop-0913:11Ag
- 9 RlghtSullom Universal 12.1.05 RSU02818 Page 1
R"� C:1UsersWasonlDocumenls%Wrighlsoft HVACIMW-57 TACOMA.rup Calc = MJ8 Front Door faces: 8
OVERED
LMAI
�Na
6z646 NOOK
65 CFM
Ir�L1 12 22CFM
CFM
lox 10,18
181 CFM 9Y
3 r
GREAT ROOM
sxeI
O 87 CFM 0.
6•. 0 4-�
ML 12x12x
203 Ca
MT
10z 10z8
BEDROOM 2 184CFM
AHU 5-TON
6-TON `.
6x
17
r u.
I
BCTON
2 CAR GARAGE
GHO HOMES
MW-57
9630 KNOLLWOOD LN
FORT PIERCE, FL 54951
LDINING
COVERED
PORCH
I� I�
L------�
T-STAT SHALL BE WITHIN 3FEET
HORIZONTALLY OF MAIN RETURN
DO NOT SCALE PLANS
MASTER
SUITE
121 3CFM I
12 CFM J
x9mi�
to WIC
112-
W! 12'O
FLEX 0x6x4
1 22 CFM
—8xx88x6
74 CFM
MASTER
BATH
10x 10x8
160 CFM DEN