The Most Durable
Heat Pump Available
You wouldn't put a plastic A/C unit in your backyard.
Why settle for less with your heat pump? Rheem
is the only heat -pump on the market with a steel case.
Avoid expensive replacements and make a Rheem the last
heat pump you need to buy. Its compact design features
a durable steel case, made to withstand common corrosion
and direct impact.
Ultra -Quiet, 1
Swept Wing Fan I
Most Models
Titanium tube heat exchanger
Super Durable Heavy
Duty Steel Case
n.
E
o c
o
C3
co Lo
CO
o
U O
Cn 2
A
Our durability goes beyond the surface, too, with a titanium
Long -Lasting
tube heat exchanger that's practically indestructible. Other
Copeland Compressor
manufacturers use cupro-nickel that cause costly maintenance
or even worse - replacement.
--
-- _.... ...... ....
._....... _ _
...__
power
Heat Only
I Heat -Cool I
Defrost
t
Model,1ti M3450ti M4450ti1
1
1
1 1
1 •D i
BTUH output ® 80,80,80' 48,000 62,000 80,000 103,000
119,000
140,000
115,000 137,000
i
119,000 :.
BTUH output ® 80,63,80' 46,000 60,000 77,000 97,000
113,000
130,000
109,000 129,000
113,000
C.O.P High Ambient @ 80,80,80' 6.2 5.7 6.0 6.0
5.9
5.6
5.9 5.3
5.9
C.O.P High Ambient @ 80,63,80' 6.0 5.5 5.8 5.7
5.7
5.3
5.7 5.2
5.7
C.O.P Low Ambient ® 50,63,80' 4.0 4.0 4.0 4.0
4.0
4.0
4.0 4.0
4.0
'Tested to AHRI 1160
'ra
1
6D°
MIN
3 AIR FLOW OUT 127
MIN I I MIN
FT_,
LAAIR ^ !— AIR
GAS , FLOW— ^ FLOW
HEATER IN IN
O'
Fig. 1: Installation Clearances
• Irrigation water should be directed away from the All wiring must be in accordance with the National
C heat pump pool heater -water spray can damage Electrical Code, NFPA No. 70, latest edition, and all
the heat pump pool heater. applicable state and local codes. Wiring diagrams are
located on pages 22 through 26.
• Rain water run offs- the heat pump pool heater
can withstand normal rain. Install rain gutters to
prevent direct steams of rain water to the heat
pump pool heater.
• It is important to keep the area next to the heat
pump pool heater clear of shrubs, bushes and
chemicals containers. They could prevent air from
circulating fully through the heat pump pool heater,
and will affect the operation of the heat pump pool
heater or damage the heat pump pool heater.
• When installed in areas where freezing tempera-
tures can be encountered; drain the water circuit
to prevent possible freeze-up damage. See the
Freeze Protection Section.
• For high wind installation requirements, refer to
the diagram on pages 8 and 9.
Electrical Connections
Refer to the unit rating plate below the control panel for
precise power requirements for your unit, and for
ampacity and over -current protection requirements.
7
NOTE: Refer to the National Electrical Code, Article
680, for general requirements for swimming pools
and equipment, and to Article 440 for special consid-
erations necessary for circuits supplying hermetic
refrigeration motor/compressors.
• Locate the equipment disconnect means within 3
feet of the heater's electrical enclosure, or as
close to the heater as possible. Always satisfy
applicable codes and standards.
• In sizing power wiring, be especially aware of up -
sizing requirements necessary due to wiring
distances. Always satisfy applicable codes and
standards.
• Electrical installation should be done by a licensed
electrician only.
This unit is pre -wired to work with external control sys-
tems, heat -on -demand options and other external time
clock overrides. Refer to the external control system's
instructions, and page 27 of this manual, for installa-
tion information.
0
THIS O MAY NOTR AFFEAEXACTLY lMEYCURSPECIFIIC NM
PAD SPECIFIC-eT1ON:
GREATER THAN O EQUAL
TO4PAD LENGTH GREA7ES SOLID
ORE�UN.TOUNIT LENGTH +G' LOAD RATING
PAD WIDTH GREATER THAN OR EQUALTO UNIT WIDTH 4r
COVERED UNIT
�\
�\
NOT INCLUDING
ISOLATOR PADS
�\
SEE HIGH WIND LOAD
,� RESTRAINT DETAIL 1
186 MPH, 3 SEC. GUST IN ACCORDANCE WITH:
ASCE 7-2010 CHAPTER 30 WIND LOADS - COMPONENTS AND CLADDING
FLORIDA BUILDING CODE 2010-SECTION 1609 WIND LOADS
FLORIDA BUILDING CODE 2010- SECTION 1620 HIGH VELOCITY HURRICANE ZONES - WIND LOADS
I
MINIMUM 18 GA. X 5' WIDE GALV. STEEL STRAP
(G90) OR EQUIVALENT G 412jj(MIN. CITY
OF 4 STRAPS)
EWA�CH 8)TRAP (A1112* NN. t00p HR. COATING) SELF DRILLING SCREWS
M
(4) VIBRATION ISOLATION -m:c-••.�.r-.....-._-.••�w:...-•.`r•.�-�.•::.-.-..•.a..-e:...--
PADS TYP. EA. CORNER "'�"J�'�'
CONCRETEPAD (2LENGTHCONCRETEToNSCREWS
(SEE PAD SPECS.) LENGTH TO PENETRATE
23I8' MINIMUM.
_ 27' MIN
32' MAX HIGH WIND LOAD RESTRAINT DETAIL 1
RESTRAINT
SPACING
2-12'MIN.
/ SPACINGTYP.
C
QT MODEL HURRICANE TIE DOWN SPECIFICATIONS
nA.oPAN+xcasnaA THIS ORAVANG DrtOmED FOR POOLHEATERSONLYnrumramanTcvcu+t.
pAD �PEGIFlCATIOM
GREATERTHAN OR EO PAALDTLENGHICK SOLID COTH GREATER NCRRAN OREOUAF TO1. OR GREATER LOAD RATING
PAD WIDTH GREATER THAN OR EQUAL TO 42.5'
SEENIGHYMI)LOAD
RESTRAINT MAIL I
AM
rat
IER
E
COY[
AM
OI.IQ
VAIF
w
S .._..
SPACWO TYR
MINIMUM 18 GA. X 7.75' WIDE STAINLESS STEEL
TIE GOWN (MIN.OTY.OF-0 TIE DOWNS) WITH (0)
1k' LONG 012 SELF DRILLING SCREWS EACH
STRAP (MIN. 1000 HR. COATING)
,..).... ... ..D.....�1 Ll> Cv c
CONCRETEPAD� 2.078'
(SEE PAD SPECS.)
HIGH WIND LOAD RESTRAINT DETAIL I